Sei sulla pagina 1di 202

GAS BOOK

Metering & Systems


GAS BOOK
Metering & Systems

Our technical sheets are reviewed regularly.


To download the latest versions and to receive new product bulletins,
please consult www.itron.com
GAS BOOK
© Copyright Itron May 2012
All rights reserved. No part of this
publication may be reproduced,
transmitted, in a retrieval system, or
translated into any language in any form
by any means without the written
permission of Itron.

Published by Itron Marketing METERS & MODULES


Communications Department with the
collaboration of the Itron Product Standard Residential Metering
Managers Meters
ª ACD G1.6.................................................................................. 19
Design & Production: Jacques Pirault
Photos: Mohamed Khalfi, Madjid ª GALLUS ..................................................................................... 25
Djavadi, Itron Image Bank ª RF1 .................................................................................................... 31
Printed in France May 2012 ª U6, SC6 & U16 .................................................................. 39
www.itron.com
Standard Commercial + Industrial
Contact: Energy EMEA MarCom Metering
Manager lynn.collins@itron.com
Data Logger
ª Sparklog .................................................................................... 43
Diaphragm Metering
ª ACD G10-G16 .................................................................... 47
ª G25-G40 ................................................................................... 55
ª G65-G100 ............................................................................... 63
Gas Analyzer
ª ANGus .......................................................................................... 67
LIMITATION OF LIABILITY
The authors have tried to provide complete Quantometer
and correct information in this handbook. ª MZ ...................................................................................................... 73
But Itron will be bound by this information
only after confirmation and will not assume ª Delta QD .................................................................................... 79
any liability for the use of this information
for any purpose. Furthermore, Itron reserves Rotary
the right to change the specifications in this ª Delta ................................................................................................ 81
handbook without prior notice.
Static
ª DATTUS...................................................................................... 95
Turbine
Printed on 100% ª Fluxi 2000/TZ ..................................................................... 97
recycled paper
GUIDE
About Itron................................................................................. 4

Introduction to Gas Technology ª Gas Measurement Glossary......................... 7


ª Meter Application .........................................................6 ª Gas Families ........................................................................ 9
ª Technologies ......................................................................6 ª Conversion Tables .................................................. 10

Overview Smart Residential Software


and Commercial & Industrial ª Saturne .................................................................................... 127
Metering .............................................................................. 107 Accessories
ª ISB + ........................................................................................... 157
Smart Residential Metering
Meters Smart Payment
ª “e” series ............................................................................... 109 Meters
ª “c” series ................................................................................ 113 ª GALLUS i V PSC............................................................. 163
ª “o” series ................................................................................121 ª RF1 i V PSC ........................................................................... 167
Software Software
ª Saturne .................................................................................... 127 ª 3E - Eclipse Enterprise Edition.................171
ª 3E - Field Work Management ...................175
Smart Commercial + Industrial
ª 3E - Replication Suite ...........................................179
Metering
ª 3E - Reporter................................................................... 181
Meters
ª 3E - Smart Payment.............................................. 183
ª “e” series ............................................................................... 109
ª 3E - Eclipse Vending Gateway ................ 187
ª “c” series ................................................................................ 113
Diaphragm Metering
ª ACD G10-G16 ................................................................ 131
ª G25-G40 ............................................................................... 131
GAS REGULATOR TECHNOLOGY
ª G65-G100 ........................................................................... 131 ª Overview............................................................................ 189

Communication Modules
ª Cyble Sensor ATEX ................................................ 133
METER DATA MANAGEMENT
Volume Converter
ª Corus.......................................................................................... 137 Data Management Software
ª Corus Compact........................................................... 145 ª IEE Meter Data Management ................... 195

Modem
ª FOCUS +................................................................................151

3
About Itron
Itron is the leading provider of energy and KEY DATES
water resource management solutions for Itron is a trusted partner to the global
nearly 8,000 utilities around the world. utility industry – and through acquisitions
We offer end-to-end solutions that include and mergers, has been for over 130 years.
electricity, gas, water and heat
measurement and control technology; 1881: Creation of Compagnie des Compteurs
communications systems; software; and in Paris
professional services. 1970: Schlumberger acquires Compagnie
des Compteurs
With nearly 9,000 employees doing 1977: Itron founded by a group of
business in more than 130 countries, Itron engineers in the US
empowers utilities to responsibly and 2001: Schlumberger ceases its metering
efficiently manage energy and water activities, Actaris is created
resources. 2004: Itron acquires Schlumberger Electricity
To realize a sustainable future, start here: Metering US
www.itron.com 2007: Itron acquires Actaris
2009: Itron and Actaris both operate under
the Itron brand

4
Itron Worldwide

Itron Gas Products & Solutions Itron has a Total Commitment to Quality. It runs
Gas demand is rising worldwide and market regular TQM employee programs focussing on
deregulation is increasing. Gas producers and quality and customer satisfaction and has a state-
distributors worldwide need fast, safe, accurate, of-the-art approach to manufacturing processes
reliable metering systems to stay competitive using Kanban, Kaisen & “Lean” practices.
and “smart” products to respond to Itron Gas Portfolio
governmental directives.
Itron provides safe, quality products, strong
Itron meets these requirements by designing proven expertise and innovative solutions for
and manufacturing technically-advanced gas Smart Gas, Smart Payment and Energy Metering.
management products and systems & providing Itron is present all along the gas “information”
complete “smart” solutions. chain, in all gas segments, worldwide.
With over 100 years experience, Itron delivers The following pages describe Itron’s extensive
high quality, safe products. It has extensive portfolio and includes the technical specifications
R&D expertise and strong sales, customer of many of these products. We recommend
support engineering and manufacturing however that you check our web site regularly
presence worldwide with an international for more details, the latest updates, and
workforce operating locally. information on new developments.

5
Introduction to Gas Technology
1.1 METER APPLICATION 1.2 TECHNOLOGIES
When metering is used for billing purposes,
the essential value sought is the energy
consumed. To obtain this value the volume
of the reference conditions must first of
all be known. This information is then
processed manually using the average
volumetric calorific value to obtain the
corresponding energy.
A metering chain includes one or more
primary sensors corresponding to
auxiliary functions of processing and
correction. History and experience have
confirmed the superiority of direct volume
measuring systems (meters).
These meters measure the volume of a
given gas, which is then computed and
shown on an index (Totaliser). Volume Gas
25-100 bar Meters are divided in two categories:
4-25 bar
Volumetric Gas Meters
0.02-4 bar (displacement meters)
ª Diaphragm gas meters
ª Rotary displacement meters
ª Wet gas meters
Various factors need to be considered ª Fluidic gas meters
when a metering system is selected The volume is measured by periodically
ª Technical: type of gas, flow, pressure, filling and emptying one or more
permissible pressure drop, load measuring devices.
variation, accuracy, dependability,
Velocity Gas Meters (flow meters)
expansibility etc.
ª Turbine meters
ª Practical: available space, operating
personnel, type of sales contract, etc. ª Quantometers (non-fiscal turbine meters)
ª Legal: metering of fiscal transactions ª Ultrasonic meters
or internal consumption monitoring, The volume is measured by fixed
mandatory standards, verification by measuring devices moved or altered by
independent authorities, etc. the flow rate.
ª Financial cost of system, operating
Quality Features
expenses, cost of distributed energy,
etc. The main quality features of a gas meter
are load range, calibration, operation
Itron gas meters are designed to take all
error limits, pressure loss, effective range
of these factors into account.
and rangeability.

6
Use of meters
Type of meter Rangeability DM = Diaphragm Meter
(Turndown ratio) FM = Fluidic Meter
RPDM = Rotary Positive Displacement
TM = Turbine Meter
DM-FM 1:160 QM = Quantometer (non fiscal turbine)

RPDM
1:20 to 1.200

TM 1:30
1:20
QM
1:16
Qmax
160 250 1600 10000 m3/h

1.3 GAS MEASUREMENT GLOSSARY


Working flow rate range of the gas Pressure loss (or pressure absorption)
meter The pressure loss is the difference
The range of flow rates limited by the between the pressures at the inlet and
maximum flow rate, Qmax, and the the outlet of the gas volume meter while
minimum flow rate, Qmin. the gas is flowing.

Rangeability (turndown ratio) Error (of indication)


This is defined as the maximum flow The volume indicated by the gas meter
divided by the minimum flow. This ratio minus the conventional true value of the
indicates a meter’s capacity to measure measurand.
volumes accurately for highly variable Vi - Vc
loads. E= x 100
Vc
Working pressure Vi is the indicated volume and Vc is the
The difference between the absolute conventional true volume.
pressure of the gas to be measured at
the inlet of the gas volume meter and the
atmospheric pressure.

7
Error limits (Maximum Permissible Errors)
Errors are expressed in relative value (percent). The following table represents the OIML
recommendations (International Organisation for Legal Metrology).

Initial verification MPE % In service MPE %


Meter Type
Flow rate Q Flow rate Q
Qmin ≤ Q < 0.1 Qmax 0.1 Qmax ≤ Q < Qmax Qmin ≤ Q < 0.1 Qmax 0.1 Qmax ≤ Q <
Diaphragm Meter ±3 ±1.5 -6/+3 ±2
Qmin ≤ Q < 0.1 Qmax 0.1 Qmax ≤ Q < Qmax Qmin ≤ Q < 0.1 Qmax 0.1 Qmax ≤ Q <
RPD Meter ±2 ±1 ±3 ±1.5
Turbine Meter ±2 ±1 ±3 ±1.5
Reference Conditions Non-Reference Conditions
Volume Conversion
±0.5 ±1
Device

The initial verification error limits are valid Pulse Generator


for the first calibration and for the Gas meters can be equipped with pulse
repetition of the calibration (re-calibration). generators whose function is to transmit
However, for operation and diagnoses, the measured values by electric pulses.
in service error limits are valid. Pulse generator connections must show
They are double the calibration error limits. a transmission of their pulse values in the
Errors with the same prefix must not form of pulses/m3 or dm3/pulse.
together exceed the 50% line of the
Volume Conversion
admissible ± error limits.
The volume of a gas depends on its
Diagnosis pressure, temperature and composition.
The diagnosis shows whether a calibrated In order to bill a volume measured
measuring device meets the operating by a gas meter, an electronic volume
error limits. converter (EVC) associated to the meter
calculates the volume occupied by
Re-calibration the same quantity of gas at reference
Calibrated measuring devices can be re- (base) conditions. This process is called
calibrated if they fulfil the valid calibration volume conversion. There are three
error limits and the requirements for the types of operating parameters: pressure,
first calibration. temperature and the compressibility
factor of the gas being measured.
The conversion can therefore be more or
less precise if it takes into consideration
one, two or all three parameters at the
same time (T conversion, PT conversion
and PTZ conversion).

8
The general conversion formula is: References:
Vb = Vm*[(P/Pb)*(Tb/T)*Zb/Z)] OIML R6, R31, R32
Vb = Converted volume at Pb and Tb ISO/DIS 9951
base conditions
Vm = Unconverted volume, measured by Europe:
the meter EC directive 71/318, 22/2004
Tb = Absolute base temperature, EN standards:
expressed in Kelvin (Generally 0°C EN 1359: Diaphragm gas meters
or 15°C)
EN 12261: Turbine gas meters
Pb = Absolute base pressure, expressed
EN 12480: Rotary displacement gas meters
in absolute bar (Usually 1.01325
bar) EN 12405: Volume converters
Zb = Gas compressibility factor in basic
USA:
conditions
ANSI B109.1, B 109.3
T = Absolute gas temperature
expressed in Kelvin
P = Absolute gas pressure, expressed
in absolute bar
Z = Gas compressibility factor

2 GAS FAMILIES

Typical values according to EN 437:2003:


Wobbe index Characteristics of representative test gas*
Gas families Min Max Composition Hi Hs
d
MJ/m3 MJ/m3 % MJ/m3 MJ/m3
1st family 22.4 24.8
CH4 = 26
Group A 22.4 24.8 H2 = 50 13.95 15.87 0.411
N2 = 24
2nd family 39.1 54.7
Group H 45.7 54.7 CH4 = 100 34.02 37.78 0.555
CH4 = 86
Group L 39.1 44.8 29.25 32.49 0.612
N2 = 14
Group E 40.9 54.7 CH4 = 100 34.02 37.78 0.555
3rd family 72.9 87.3
n-C4H10 = 50
Group B/P 72.9 87.3 116.09 125.81 2.075
i-C4H10 = 50
Group P 72.9 76.8 C3H8 = 100 88.00 95.65 1.550
n-C4H10 = 50
Group B 81.8 87.3 116.09 125.81 2.075
i-C4H10 = 50
* Dry gas at 15°C and 1013.25 mbar

9
3 CONVERSION TABLES

Equivalents and Conversion of English/US and European Measures


SI Units US or UK Units Conversion
Quantity
Name Symbol Name Symbol SI to Us or UK US or UK to SI
Lenght millimetre mm inch in 1 mm = 1 inch =
0.03937 in 25.4 mm
metre m foot ft 1 m = 3.281 ft 1 ft = 0.3048 m
metre m yard yd 1 m = 1.0936 yd 1 yd = 0.9144 m
kilometre km mile mi 1 km = 1 mi =
0.6214 mi 1.609 km
Area square mm2 square inch in2 1 mm2 = 1 in2 =
millimetre 0.00155 in2 645.2 mm2
square m2 square foot ft2 1 m2 = 1 ft2 =
metre 10.7643 ft2 0.0929 m2
square m2 square yard yd2 1 m2 = 1 yd2 =
metre 1.1959 yd2 0.8361 m2
square km2 square mile mi2 1 km2 = 1 mi2 =
kilometre 0.3861 mi2 2.59 km2
Volume cubic cm3 cubic in3 1 cm3 = 1 in3 =
centimetre 0.061 in3 16.39 cm3
cubic dm3 cubic foot ft3 1 dm3 = 1 ft3 =
decimetre 0.0353 ft3 28.32 l or dm3
(1 dm3 = 1 l)
cubic m3 cubic yard yd3 1 m3 = 1 yd3 =
metre 1.037 yd3 0.765 m3
litre l US gallon US gal 1l= 1 US gal =
0.2642 US gal 3.785 l
litre l UK gallon UK gal 1l= 1 UK gal =
0.2200 UK gal 4.576 l
Mass gram g ounce oz 1 g = 0.0353 oz 1 oz = 28.35 g
kilogram kg pound lb 1 kg = 2.204 lb 1 lb = 0.4536 kg
tonne t short ton sh tn 1t= 1 sh tn =
1.1023 sh tn 0.9072 t
tonne t long ton UK ton 1t= 1 UK ton =
0.9842 UK ton 1.0160 t
Pressure megaPascal MPa pound (force) lbf/in2 1 MPa = 1 lbf/in2 =
per square inch 145 lbf/in2 or psi 0.0069 MPa
bar bar pound (force) lbf/in2 1 bar = 1 lbf/in2 =
per square inch 14.5 lbf/in2 0.069 bar
Newton N/m2 pound (force) lbf/in2 1 N/m2 = 1 lbf/in2 =
square metre per square inch 0.000145 lbf/in2 6900 N/m2
Moment Newton Nm pound (force) lbf ft 1 Nm = 1 lbf ft =
of a couple metre foot 0.73756 lbf ft 1.3558 Nm

10
Equivalence of Energy Units
cal kcal Mcal J kJ MJ Wh kWh
1 cal 1 0.001 0.000001 4.2 0.0042 0.0000042 0.001163 0.000001163
1 kcal 1000 1 0.001 4200 4.2 0.0042 1.163 0.001163
1 Mcal 1000000 1000 1 4200000 4200 4.2 1163 1.163
1 Gcal 1000000000 1000000 1000 4200000000 4200000 4200 1163000 1163
1J 0.24 0.00024 0.00000024 1 0.001 0.000001 0.000278 0.000000278
1 kJ 240 0.24 0.00024 1000 1 0.001 0.278 0.000278
1 MJ 240000 240 0.24 1000000 1000 1 278 0.278
1 Wh 860 0.86 0.00086 3600 3.6 0.0036 1 0.001
1 kWh 860000 860 0.86 3600000 3600 3.6 1000 1
Example: 1 MJ = 0.278 kWh

Equivalence of Power Units


kcal/h kcal/min J/s kJ/h MJ/h W kW
1 kcal/h 1 0.0166 1.163 4.2 0.0042 1.163 0.001163
1 kcal/min 60 1 70 251 0.251 70 0.07
1 J/s 0.86 0.0143 1 3.6 0.0036 1 0.001
1 kJ/h 0.24 0.004 0.278 1 1.001 0.278 0.000278
1 MJ/h 239 3.98 278 1000 1 278 0.278
1W 0.86 0.014 1 3.6 0.0036 1 0.001
1 kW 860 14.3 1000 3600 3.6 1000 1
Example: 1 kcal/min = 70 W

11
Gas Distribution System
Transmission Pressure Regulation Point
Distribution
Metering Point
Distribution
Service

City Gate Station

12
District Regulation Station

13
w w w. i t r o n . c o m

14
Meters & Modules

15
w w w. i t r o n . c o m

16
Meters & Standard Standard
Modules Residential Commercial
Metering + Industrial
Metering
Data Logger Sparklog 43
Diaphragm Metering ACD G1.6 19 ACD G10-G16 47
GALLUS 25 G25-G40 55
RF1 31 G65-G100 63
U6, SC6 & U16 39
Gas Analyzer ANGus 67
Quantometer MZ 73
Delta QD 79
Rotary Delta 81
Static DATTUS 95
Turbine Fluxi 2000/TZ 97

17
w w w. i t r o n . c o m

18
ACD G1.6
Residential Diaphragm Gas Meter

The ACD G1.6 is Itron’s latest generation KEY BENEFITS


residential diaphragm meter designed to meet ª Ready for remote reading
the needs of fast growing gas markets and data management
worldwide. It combines accuracy and durability ª Ultra-compact design
in a highly compact casing. Through our proven ª Long-term accuracy and
know-how in gas measurement, combined with reliability
the use of modern engineering and production ª Robust, maintenance-
techniques, Itron has developed this compact, free meter
robust and highly accurate meter, ensuring ª High resistance to
reduced shipping costs, easier handling and corrosion
simplified installation.

APPLICATION accuracy and stability over time. It is


The ACD G1.6 residential diaphragm gas ideally suited to meet the needs of
meter is typically used for cooking and emergent gas markets or customers with
hot water heating applications requiring consumption up to 2.5 m3/h.
accuracy at low to medium gas flow
OPERATING PRINCIPLE
rates. It is designed for use with natural
gas, LPG and all non-corrosive gases. The movement of the diaphragm is due
to the pressure difference between the
METROLOGY inlet and the outlet of the meter. The gas
It is MID and EN1359 compliant, and enters one side of the diaphragm plate,
meets many other demanding national while on the other side it sluice through a
metrological standards. During separate port on the valve. When one
preliminary calibration controls, the meter side is full, the rotating mono-valve moves
is 100% tested according to customer or on to the next position, allowing gas to fill
national requirements. the empty side. A transmission gear and
a mechanical stuffing box transfer the
With its ultra-compact robust design, the reciprocating motion to the index.
ACD G1.6 ensures a consistent level of

SPECIFICATIONS knowledge to shape your future 19


Error (%) EN1359 & OIML approval limits IRAM 2717 (2000)
4
ACCURACY
3
CURVE
2
1
0
-1
-2
-3

-4
Qmin 2 Qmin 0.1 Qmax 0.2 Qmax Qmax
Flow rate (m3/h)
Pressure loss (mbar)
3,5
PRESSURE LOSS ane
3,0 But
CURVE
2,5 e
pan
Pro
2,0
= 1)
1,5 Air (d

)
1,0 NG (d = 0.6

0,5

0,0
0 0,5 1 1,5 2 2,5
d= density ratio Flow rate (m3/h)

CONSTRUCTION
The ACD G1.6 meter contains four ➊ Measuring Unit
main parts: The 0.7 litre measuring unit has high
gliding properties to reduce wear on
kinematic parts and consists of the
following components:
➌ ➍ ª Four measuring chambers, separated
by synthetic diaphragms.
ª A distribution system with a rotating
mono-valve.
ª An outlet pipe.
All materials have been selected for their
➊ superior resistance to chemicals and gas.
A back-run stop prevents the meter from
running backwards.

➋ ACD G1.6 Parts


➋ Casing
A gas-tight casing, highly protected from
corrosion. Two different casing materials
are available:
ª Steel casing.
ª Aluminium casing.

20 ACD G1.6
➌ Mechanical Transmission ª “c” series: mechanical index equipped
with a Cyble target for retrofittable
A stuffing box transmits the movement of
AMR communication systems. This
the measuring unit to the totalizer.
Itron standardised meter interface
allows the adaptation of different Cyble
➍ Totalizer modules as a communication device.
A totalizer is available in cubic meters
(standard) or kWh (optional). ª “o” series: mechanical index available
Depending on the application, different with a permanent magnet in an index
totalizer versions can be ordered: drum. Can be retrofitted with a Low
Frequency pulse transmitter (Reed
switch).

Technical Specifications
The following table shows all technical features affecting the measuring unit and the
meter casing
Gas Type Natural gas, LPG and all non-corrosive gases
Cyclic Volume 0.7 dm³
Temperature Range Gas: -10°C to +40°C
Ambient: -10°C to +40°C
Storage: -30°C to +70°C
Maximum Operating Steel 0.5 bar (0.1 bar HTL version)
Pressure Aluminium 0.5 bar (1.0 bar optional)
Measuring Range G0.6 Qmin 0.016 m³/h
Qmax 1 m³/h
G1 Qmin 0.016 m³/h
Qmax 1.6 m³/h
G1.6 Qmin 0.016 m³/h
Qmax 2.5 m³/h (3 m³/h optional)
Casing Material Sheet steel
Aluminium alloy
Accuracy Class 1.5
MID (04/22/EC) module H1
Approval Local approvals like IRAM2717:2000, Portaria 31/1997, GB/T 6968 -1997,
NOM-106-SCFI-2000 etc.
Flow Direction Left to Right (standard) or Right to Left (optional)
Connections Metric standards: M26 x 1.5 / M30 x 2
IS0228 standards: G7/8” / G¾” / G1”¼
NPT standards: (Upon request)
BS746 standards: 1”
Others: W28.8x12
Specials connections on request.
Colour Grey RAL 7040 for Latin America
Grey RAL 7042 for Asia
Other colors on request

ACD G1.6 21
QUALITY ASSURANCE
World-class engineering in a ISO 9001 certified design centre in Reims, France.
World-class manufacturing in a ISO 9001 certified operations unit in Buenos Aires,
Argentina, and Chongqing, China.

TOTALIZER FEATURES

“c” series
Smart ready, allowing for future AMR capabilities
Itron’s latest-generation mechanical index meter comes standard with our Cyble™
target, and can be upgraded in the field to implement AMR and enable remote reading
via different communication technologies.
Key advantages of “c” series
ª Ready for smart metering
ª Can be retrofitted on site without recalibration of meter
ª Reliability of an electronic switch (no wear or bouncing)
ª Principle proven on the field with 20 years experience
ª Pre-equipment is immune to magnetic tampering

“o” series
Retrofit enabling smart upgrades to existing meter park
The “o” series addresses traditional meters with a mechanical index, already installed in
the field, to minimize stranded assets when AMR/AMI is required. LF transmitters - via
a Reed switch - and a Pulse RF radio module transform pulses into transmittable data.

Building Blocks of Itron’s “c” series

Mechanical AnyQuest &


ACD index, EverBlu Cyble,
inductive Cyble M-Bus,
G1.6 pulse Cyble Sensor

Base Meter Index Communication


Module
Totalizer characteristics “c” series
Meter Size G0.6 / G1 / G1.6
European Metrological Approval N° LNE-21197
(04/22/EC - Module H1)
Display Mechanical index with 8 drums (3 decimals)
Transmission Rate 0.01 m3 / rotation
Transmission System Cyble™ target
Mechanical Environment M1
Electronical Environment E2

22 ACD G1.6
Building Blocks of Itron’s “o” series

Mechanical
ACD index,
AnyQuest
& EverBlu
magnetic
G1.6 pulse
Pulse

Latin America version Asia version


Base Meter Index Communication
Module
Totalizer characteristics “o” series
Meter Size G0.6 / G1 / G1.6
European Metrological Approval N° LNE-21197
(04/22/EC - Module H1)
Display Mechanical index with 8 drums (3 decimals)
Pulse Generator Standard 0.01 m3 / pulse (optional 0.1 m3 / pulse)
Pulse Transmitter Retrofittable LF system, 12 Vdc max - 10 mA max.
standard 0.01 m3/pulse.
Mechanical Environment M1
Electronical Environment E2

Dimensions and Weight


E Weight
Casing Distribution A B C D mm kg
Entry F
Material Channel mm mm mm mm “c” “o” “c” “o”
series series series series
Steel Top Asia 110 196 58 186 147 n/a 1.5 n/a
Aluminium Top SA 110 200 55.5 171 n/a 145 n/a 1.48
SA 130 200 55.5 171 n/a 145 n/a 1.55
SA 100 198 58 178 145 n/a 1,56 n/a
SA/Asia 110 198 58 178 145 n/a 1.59 n/a
Asia 110 175.5 55.5 171 n/a 139 n/a 1.41
Asia 130 175.5 55.5 171 n/a 139 n/a 1.41
Aluminium Side Asia 169 188 55.5 171 n/a 139 161 n/a 1.37
SA = South America Please consult us for any other requests.
D E
A C A E
C
B

B
F

ACD G1.6 Top Entry ACD G1.6 Asia Side Entry

ACD G1.6 23
ACD G1.6 steel casing version
ACD G1.6 for Asia

ACD G1.6 110mm for Latin America ACD G1.6 Side Entry

OPTIONS
Ordering Information
ª Outlet test pressure connector
ª Side entry connection ª Measuring range
ª Anti reverse flow valve ª Maximum working pressure
(available for aluminum casing only) ª Meter interaxis and connection type
ª Specific marking
(serial number, logo, bar code)
ª Options (e.g. wired/wireless
communication)

24 GA-ACD-G1.6-EN-V2.0-2011.07
GALLUS KEY BENEFITS
ª Operational efficiency
with remote meter reading
Residential Diaphragm Gas Meter
ª Manage usage and
resources with timely,
Today’s gas providers are tasked with delivering accurate data
a reliable, quality product at the best possible ª Compact design fits a
cost. To do so, they need to operate more variety of installation
efficiently, and accurately measure and manage environments
their resources. Itron’s GALLUS meter is a ª Reliable and maintenance-
compact, residential gas meter designed for the free meter design
measurement of natural gas, LPG and all non- ª Standards compliant
corrosive gases. across multiple ranges

With over 30 million units installed and in APPLICATION


service, the GALLUS is one of the most The GALLUS meets MID and EN1359
trusted residential metering devices in (certificate delivered by the LNE), and more
the world. Compliant with international than 25 national metrological standards.
O.I.M.L and EN1359 standards, as well Its compact design makes the GALLUS
as more than 25 national metrological the right choice where a precise and
standards, the GALLUS is designed for reliable measurement for medium flow
use in markets where reliable, accurate rates is required.
metering are required. And because it
is optionally factory-equipped with our
Cyble™ technology, the GALLUS helps
your meter reading processes become
more efficient.

SPECIFICATIONS knowledge to shape your future 25


METROLOGY OPERATING PRINCIPLE
In addition to the EN1359/A1:2006 The GALLUS is a positive displacement
standard compliance, the GALLUS diaphragm gas meter with a stand-alone
meets many other demanding national twin chamber measuring unit.
metrological standards. During preliminary The twin chambers are each fitted with a
test bench controls, the meter is 100% flexible and gas-tight diaphragm, which
tested according to customer or national is moved by the differential between the
requirements. inlet and outlet pressure.
The design and the careful materials Gas enters one side of the diaphragm
selection of the GALLUS enable it to plate, while on the other side it sluice
meet the highest demand in international through a separate port on the valve.
markets in terms of accuracy and When one side is full, the rotating mono-
long-term stability. valve moves on to the next position,
During the preliminary test controls on allowing the gas to fill the empty side.
the sonic nozzle test benches, all meters A transmission gear and a mechanical
are tested at Qmin, 0.2 Qmax and Qmax. coupling or stuffing box transfer the
reciprocating motion to the mechanical,
retrofittable index.
The measuring unit is housed in a robust,
gas-tight casing.
ACCURACY CURVE
Error (%) EN1359 & OIML approval limits
4
3
2
1
0
-1
-2
-3
-4
Qmin 0.1 Qmax 0.2 Qmax Qmax
Flow rate (m3/h)

PRESSURE LOSS CURVE


Pressure loss (mbar)

2.0
ne
Buta pan
e
Pro
1.5
1)
Air (d =
1.0
)
NG (d = 0.6
0.5
Q m3/h
0.0
1 2 3 4 5 6
d = density ratio Flow rate (m3/h)

26 GALLUS
CONSTRUCTION All materials used in the production of the
GALLUS meter have been selected for
their superior resistance to chemicals
and gas. A back-run stop prevents the
meter from running backwards in case of
➌ tampering.

➋ Casing
➍ A gas-tight casing, highly protected from
corrosion. Two different casing materials
are available:
ª Steel casing.
ª Aluminium casing.
With its casing in steel, high protection
➊ against corrosion is ensured by 500 hours
of salt fog spray testing and resistant
cataphoresis treatment. The aluminium
version can withstand up to 1000 hours of
salt fog spray test. The extreme strength

GALLUS Parts
of the case joint is achieved by rolling the
belt and compressing the flanges into
contact with a sealant applied between
the faces. This forms a joint which is both
gas-tight and fire-resistant.
The GALLUS meter contains four
main parts: ➌ Mechanical Transmission
➊ Measuring Unit A stuffing box transmits the movement of
the measuring unit to the totalizer.
The 1.2 litre measuring unit has high gliding
properties to reduce wear on moving parts ➍ Totalizer
and consists of the following components:
A totalizer is available in cubic meters.
ª Four measuring chambers, separated The totalizer comes with an IP54
by synthetic diaphragms. protection class and an IP67 version for
ª A distribution system with a rotating specific environments. Different totalizer
mono-valve. versions can be ordered depending on
ª An outlet pipe. the application required:
The design of the fixed-stroke mechanism ª “c” series: mechanical index equipped
is the result of precision and high-quality with a Cyble target for retrofittable
automation, eliminating the need for AMR communication systems. This
an adjustable tangent. This confines all standard Itron meter interface allows the
registration adjustments to the accessible adaptation of different Cyble modules as
change wheels behind the index. a communication device (such as pulse,
Long life synthetic diaphragms, coupled M-Bus or radio frequency wireless links).
to the well-proven movement design, ª “o” series: mechanical index available
combine to give excellent stability and with a permanent magnet in an index
accuracy throughout the whole life of the drum. Can be refitted with a low
meter. frequency pulse transmitter (reed switch).

GALLUS 27
Technical Specifications
The following table shows all technical features affecting the measuring unit and the
meter casing
Gas Type Natural Gas, LPG and all non-corrosive gases
Cyclic Volume 1.2 dm³
Temperature Range Operating: -25°C to +55°C
Storage: -30°C to +70°C
Maximum Operating Steel 0.5 bar (0.1 bar HTL version)
Pressure Aluminium 1.5 bar
Measuring Range G2.5 Qmin 0.025 m³/h
Qmax 4 m³/h
G4 Qmin 0.04 m2/h
Qmax 6 m2/h
Casing Material Sheet steel
Aluminium alloy
Accuracy Class 1.5

Approval MID (04/22/EC) module H1

Totalizer IP54 (IP67 on request)


Connections Single or 2 pipe connections
Different connection threads are available (ISO 228-1 & BS746
standards, national).
Special threads on request
Colour Grey white RAL9002

QUALITY ASSURANCE
Quality assurance procedures based on ISO 9001 and strict controls throughout the
manufacturing process ensure a very high quality level and reliable product.

TOTALIZER FEATURES

“c” series
Smart ready, allowing for future AMR capabilities
Itron’s latest-generation mechanical index meter comes standard with our Cyble™
target, and can be upgraded in the field to implement AMR and enable remote reading
via different communication technologies.
Key advantages of “c” series devices include:
ª Ready for smart metering
ª Can be retrofitted on site without recalibration of meter
ª Reliability of an electronic switch (no wear or bouncing)
ª Principle proven on the field with 20 years experience
ª Pre-equipment is immune to magnetic tampering

28 GALLUS
Building Blocks of Itron’s “c” series

Mechanical AnyQuest &


index, EverBlu Cyble,
GALLUS inductive Cyble M-Bus,
pulse Cyble Sensor
Steel version Aluminium version
Base Meter Index Communication
Module
Totalizer characteristics “c” series
Meter Size G2.5 / G4
European Metrological Approval N° LNE-11827
(04/22/EC - Module B)
Display Mechanical index with 8 drums (3 decimals)
Transmission Rate 0.01 m3 / rotation
Transmission System Cyble™ target
Mechanical Environment M1
Electronical Environment E2

“o” series
Retrofit enabling smart upgrades to existing meter park
The “o” series addresses traditional meters with a mechanical index, already installed in
the field, to minimize stranded assets when AMR/AMI is required. LF transmitters - via
a Reed switch - and a pulse RF radio module transform pulses into transmittable data.

Building Blocks of Itron’s “o” series

Mechanical
AnyQuest
index,
GALLUS magnetic
& EverBlu
Pulse
pulse
i
EU version
Base Meter Index Communication
Module
Totalizer characteristics “o” series
Meter Size G2.5 / G4
European Metrological Approval N° LNE-11827
(04/22/EC - Module B)
Display Mechanical index with 8 drums (3 decimals)
Pulse Generator Standard 0.01 m3 / pulse (optional 0.1 m3 / pulse)
Pulse Transmitter Retrofittable LF system, 12 Vdc max – 10 mA max.
Mechanical Environment M1
Electronical Environment E2

GALLUS 29
Dimensions and Weight
E (mm) Weight (kg) Connection threads
Casing A B C D
“c” “o” “c” “o” (according
Material mm mm mm mm
series series series series to ISO 228-1)
Steel - 230 67 190 n/a 152 ±4 n/a 1.45 DN25 - G2”
212
100 67 190 n/a 156 n/a 1.45 DN 20 - G 1”¼
±2*
DN 20 - M24 x 1.5
219
110 67 190 165 156 1.55 1.45 G ¾” - G 1”
±9*
G 1 ¼” - G 7/8” - BS ¾”
130 225 80 240 n/a 156 n/a 1.6 G 1”¼
152.4
240 80 240 n/a 156 n/a 1.6 BS 1”
(6“)
225 DN 20 - G 1”
160 80 240 n/a 156 n/a 1.6
±2* G ¾” - G 7/8”
220 270 72 171 n/a 170 n/a 2.6 GM ¾”
Aluminium 110** 219 77 196 n/a 177 n/a 2.2 G ¾” - G 1” - G 1”¼
230/ G 7/8" - G 1”
110 73.5 227 174 170 1.9 1.8
240* G 1 ¼” - DN20
230/
130 73.5 227 174 170 1.9 1.8 M26 x 1.5
240*
152.4 230/
73.5 227 174 170 1.9 1.8 G 1 ¼”
(6“) 240*
A C * Depending on the connection height
** Meter type available for European markets only
& based on EEC approval
Please consult us for any other requests.
B

D E

GALLUS

Ordering Information GALLUS Aluminium GALLUS


EU version Asia version
ª Measuring range (G2.5 & G4)
ª Maximum working pressure
(0.1-0.5-1.5 bar)
ª Meter interaxis and connection
type
ª Specific marking
(serial number, logo, bar code)
ª Options (e.g. pressure tap, wired/
wireless communication modules)
GALLUS South America version

30 GA-GALLUS-EN-V2.0-2011.07
RF1
Residential Diaphragm Gas Meter

The RF1 is a compact residential gas meter KEY BENEFITS


designed to accurately measure volumes of ª Ready for remote reading
natural gas, LPG and all non-corrosive gases. and data management
Several versions and options are available to ª Robust construction
meet various application requirements. Its design ª Environment-friendly
minimizes installation costs and enables future ª Multi-range G1.6, G2.5,
field upgrades. G4 & G6

APPLICATION ª A reciprocating synthetic diaphragm


The RF1 long-term metrology stability ª Crank-controlled and oscillating slides
makes it the right choice for demanding, ª Robust and tight connections between
high consumption residential gas components
markets. ª The use of precise, light-weight and
noise-free plastic parts
METROLOGY
During the preliminary test controls on
The RF1 gas meter meets strict sonic nozzle test benches, all meters are
metrological requirements such as MID, tested at Qmin, O.2 Qmax and Qmax. In
O.I.M.L and EN1359 as well as different accordance with EC regulations, the
national requirements and standards maximum permissible error is +/-3% from
(such as PTB, DVGW and KVGN). Qmin to 0.2 Qmax, and +/-1.5% from 0.2
The RF1 is a combination of proven Qmax to Qmax.
and reliable gas meter concepts and
includes:

SPECIFICATIONS knowledge to shape your future 31


OPERATING PRINCIPLE separate port on the valve. When one
The RF1 is a positive displacement side is full, the sliding valve moves on to
diaphragm gas meter with a stand-alone the next position, allowing the gas to fill
twin chamber measuring unit. the empty side.
The twin chambers are each fitted with a A transmission gear and either a
flexible and gas-tight diaphragm which is magnetic coupling or stuffing box transfer
moved by the differential between the the reciprocating motion to the
inlet and outlet pressure. The gas enters mechanical or electronical index.
one side of the diaphragm plate, and The measuring unit is housed in a robust
comes out on the other side through a gas-tight casing.

ACCURACY CURVE
Error (%) EN 1359 & OIML approval limits
4

2
1
0
–1
–2
–3

–4
Qmin 0.1 Qmax 0.2 Qmax Qmax
Flow in m3/h

PRESSURE LOSS CURVE


Pressure loss (mbar)
2.00
G6
1.75

1.50
G4 G6
1.25

1.00 G4

0.75

0.50

0.25

0.00
0 1 2 3 4 5 6 7 8 9 10
Flow in m3/h
Pressure loss Air (1.2 kg/m3) Pressure loss Natural Gas (0.8 kg/m3)

QUALITY ASSURANCE
Gas meter produced in accordance with DIN EN ISO 9001/BS 5750 and DIN EN ISO
14001 requirements, to guarantee quality, accuracy and long-term stability.

32 RF1
CONSTRUCTION ➋ Casing
ª High-quality casing material with unique
corrosion resistance (aluminium / zinc-
4 coated sheet steel)
3 ª Additional coating with solvent-free paint
ª Also available in a sturdy aluminium
casing for high pressure applications
up to 1.5 bar (G6 size with 6”
connection distance only)
1 ª Molded connections ensure optimum
2
resistance to corrosion
ª Material protected against corrosion
(500h salt spray test)
ª Available with different connections
ª Integrated crimp prevents water residue
RF1 Parts ª Crimped belt version for PN 0.1,
PN 0.2, PN 0.5.
The RF1 meter contains four main parts: ª Safe, DVGW-approved sealing material
➊ Measuring Unit
➌ Transmission
ª Two-litre measuring unit
A magnetic coupling (standard) or
ª Plastics selected to facilitate meter stuffing box transmits the movement of
recycling (when possible) the measuring unit to the totalizer
ª Resistance to chemicals and gas
ª High gliding properties to reduce wear ➍ Totalizer
on moving parts Different totalizers are available
ª Optimum long-term operation depending on the application required:
ª A back-run stop prevents the meter ª “e” series: electronic index for a 2-way
from running backwards wired/wireless M-Bus communication,
ª An optional available backflow flap with optional electronic temperature
for 210-250 mm versions protects the correction and optional internal shut-off
meter against the backflow of gas valve
ª “c” series: mechanical index equipped
with a Cyble target for retrofittable
AMR communication systems. The
standardized interface allows you to
connect various Cyble communication
devices: Pulse, M-Bus, or radio
frequency wireless links
ª “o” series: mechanical index available
with a permanent magnet in an index
drum. Can be refitted with a low
RF1 frequency pulse transmitter (Reed
Measuring switch)
Unit

RF1 33
Technical Specifications
Gas Type Natural gas, air, propane butane, nitrogen and all non-corrosive gases
Cyclic Volume 2 dm3
Temperature Range Gas -25ºC to +40ºC (-10ºC to +40ºC for G1.6)
Ambient -25ºC to +55ºC
Storage -40ºC to +70ºC
Maximum Operating 0.5 bar (0.1 bar HTL version)
Pressure
Measuring Range G1.6 Qmin 0.016 m3/h Qmax 2.5 m3/h
G2.5 Qmin 0.025 m3/h Qmax 4 m3/h
G4 Qmin 0.04 m3/h Qmax 6 m3/h
G6 Qmin 0.06 m3/h Qmax 10 m3/h
Casing Material Aluminium/Zinc-coated sheet metal
Accuracy Class 1.5
Approval MID (04/22/EC) module B and D
Totalizer IP 54
Connections Single or double pipe connections
Different connection threads are available (ISO 228-1 and BS746
standards, national)
Special threads available upon request
Colour Light grey RAL 7035

TOTALIZER FEATURES
With the ECO series, Itron offers a complete portfolio to address today’s and future
energy resource and environmental challenges.
“e” series “c” series
Supporting the prevailing European Smart ready, allowing for future AMR
Communication Standards and ensuring capabilities.
interoperability Itron’s latest-generation mechanical
This smart meter equipped with an index meter comes standard with our
electronic index is designed to facilitate Cyble™ target, and can be upgraded
integration into wired and wireless fixed in the field to implement AMR and
networks. It has built-in communications enable remote reading via different
capabilities which detect reversed communication technologies.
operation, magnetic tampering and
ª Smart reading possible with additional
backflow.
modules
ª High accuracy error curve correction ª Can be retrofitted on site without
ª Optional temperature conversion recalibrating the meter
ª Built-in two-way wired/wireless M-Bus ª Reliability of an electronic switch
communication (no wear or bouncing)
ª Optional internal shut-off valve ª Proven, tested design backed by
ª Safe data transmission with AES 20 years’ experience
ª Tamper protection and detection ª Protection against magnetic tampering

34 RF1
“o” series
Retrofit enabling smart upgrades to
existing meter park
The “o” series addresses traditional
meters with a mechanical index, already
installed in the field, to minimize stranded
assets when AMR/AMI is required.
LF transmitters - via a Reed switch - and “o” series Totalizer with LF transmitter “cable”
a Pulse RF radio module transform pulses
into transmittable data.

Building Blocks of Itron’s “e” series

Electronic,
M-Bus,
index,
RF1 optical
wired,
wireless
pulse

Base Meter Index Communication


Module
Totalizer characteristics “e” series
Meter Size G1.6 / G2.5 / G4 / G6*
European Metrological Approval N° DK-0200-MI002-019
(04/22/EC - Module B)
Maximum Operating Pressure 0.5 bar
(0.2 for valve version, 0.1 bar for HTL)
Temperature Range Temperature (converted): -10ºC to +40ºC
(-25ºC to +55ºC optional for G4/G6)
Storage temperature: -40ºC to +70ºC
(>55ºC for up to 4 hours)
ATEX Approval II 2G Ex ib IIB T3
Relative Humidity Max. 93% non-condensing between -25ºC and +55ºC
Display LCD with 9 digits (4 decimals)
M-Bus Interface 300 bps / 2400 bps / one bus load, wireless or dongle
(up to four bus loads)
Battery Lithium batter with an minimum average lifetime of 15 years
under reference conditions
Standards EN12405-1: 2007-08, Directive 2004/108/EC (EMC)
and OIML D11 (EMC), NTA8130-May 2007, DSMR V2.2+
(Netherlands)
Serial Bus M-Bus slave
(wired: EN13757-2/3, wireless: EN13757-4)
Customer Port IR service interface (EN62056-21)
Mechanical Environment M1
Electronical Environment E2
* G6 version with integrated valve not EN1359:1998/A1:2006 compliant due to pressure absorption

RF1 35
Building Blocks of Itron’s “c” series

Mechanical AnyQuest &


index, EverBlu Cyble,
RF1 inductive Cyble M-Bus,
pulse Cyble Sensor

Base Meter Index Communication


Module
Totalizer characteristics “c” series
Meter Size G1.6 / G2.5 / G4 / G6
European Metrological Approval N° DE-07-MI002-PTB014
(04/22/EC - Module B) N° DE-08-MI002-PTB006 (with mechanical temperature
correction)
Maximum Operating Pressure 0.5 bar (0.1 bar for HTL)
Display Mechanical index with 8 drums (3 decimals)
Transmission Rate 0.01 m3/rotation
Transmission System Cyble™ target
Mechanical Environment M1
Electronical Environment E2

Building Blocks of Itron’s “o” series

Mechanical
index, AnyQuest
RF1 magnetic & EverBlu
pulse Pulse

Base Meter Index Communication


Module
Totalizer characteristics “o” series
Meter Size G1.6 / G2.5 / G4 / G6
European Metrological Approval N° DE-07-MI002-PTB014
(04/22/EC - Module B) N° DE-08-MI002-PTB006 (with integrated mechanical
temperature correction)
Maximum Operating Pressure 0.5 bar ( 0.1 bar for HTL)
Display Mechanical index with 8 drums (3 decimals)
Pulse Generator Standard 0.1 m3 / pulse (optional 0.01 m3 / pulse)
Pulse Transmitter Retrofittable LF system, 12 Vdc max – 10 mA max.
standard 0.1 m3/pulse.
Different versions: with 1m cable, terminal block or binder
plug (Double LF pulse transmitter)
Mechanical Environment M1
Electronical Environment E2

Special features of each totalsier version:


ª UV-resistant cover
ª Customized name plate available, e.g. bar code, logo, customer serial number.

36 RF1
Version Casing A B C D E (mm) Weight (kg)
G Size DN Threads Standard “e” “c” & “o” “e” “c” & “o”
and Connection (mm) (mm) (mm) (mm) series series series series
Single G1.6 to G6 25 G 2” ISO228-1 - 274 71 233 192 177 2.7 2.5
Double Compact G1.6 to G4 25 G 1 ¼” A ISO228-1 110 269 71 233 192 177 2.7 2.5
Double Compact G1.6 to G4 25 G 1 ¼” A ISO228-1 130 274 71 233 192 177 2.7 2.5
Double Compact G1.6 to G4 25 1 ¼” BS746 152.4 (6”) 279 71 233 192 177 2.7 2.5
Double G1.6 to G4 20 G 1” A ISO228-1 250 273 71 325 192* 177 2.9 2.7
Dimensions and Weight

Double G1.6 to G4 20 G 1” A (AT) ISO228-1 250 275 61.5 325 192* 177 2.9 2.7
Double G1.6 to G6 20 GM ¾” NEN 2373 220/250 272 71 325 192* 177 2.9 2.7
Double G1.6 to G6 25 G 1 ¼” A ISO228-1 210/250 267 71 325 192* 177 2.9 2.7
Double G1.6 to G6 25 GM 1” NEN 2373 250 273 71 325 192* 177 2.9 2.7
Double G6 32 G 1 ½” A ISO228-1 220 273 71 325 192* 177 2.9 2.7
Double G6 32 G 1 ¾” A ISO228-1 250 272 71 325 192* 177 2.9 2.7
Double G6 32 MFIT001 250 270 71 325 192* 177 2.9 2.7
Double Aluminium G6 25 G 1 ¼” A ISO228-1 152.4 (6") 320 80 297 n/a 197 n/a 4
*available with internal shut-off valve
DN A C DN C
A E

B
B B

RF1
D E D E D C

37
Double Pipe Steel Version Single Pipe Steel Version G6 Double Pipe 6” HP Aluminium Version
OPTIONS ENVIRONMENTAL ASPECTS
ª Aluminium HP version - 6” connection The RF1 range is designed to help
distance (G6 version only and special protect the environment:
totalizer type) ª Environment-friendly coating process
ª Mechanical temperature converter (water-based paint)
(-10°C to +40°C standard, other ª Lead-free sheet metal
temperatures on request)*
ª Reduced weight
ª Electronical temperature converter
ª Low noise
(-10°C to +40°C standard, other
temperatures on request)* ª Same-class plastic parts used as
much as possible
* The compensated volume on the index refers to a
base temperature of 15°C / mTC for “c” and “o” Series, ª All plastic parts are recyclable and
eTC for “e” Series. marked accordingly

RF1-MM G4 RF1 e V SW G4
Double Pipe 110 mm Version Double Pipe Version

Ordering Information
ª Measuring range
(G1.6, G2.5, G4, G6)
ª Maximum working pressure
(0.1-0.5bar)
ª Meter interaxis and connection type
ª Specific marking
(serial number, logo, bar code)
ª Options (e.g. valve, temperature
compensation, wired/wireless
communication)

38 GA-RF1-EN-V2.0-2011.07
SC6

U6

U6, SC6, U16 U16

Residential Gas Meters

Manchester has been associated with the KEY BENEFITS


manufacture of residential Gas Meters for over ª Most applications covered
150 years. In that time, the basic principle of the by Conventional and
diaphragm gas Meter has remained unchanged. Semi-Concealed models
Itron has continued to invest in modern ª Established Design
manufacturing processes and have used the ª Robust Construction
latest materials technology and design techniques ª Proven Reliability
to produce a range of meters for residential use. ª Long term accuracy and
stability
The U6 and SC6 meters incorporate a measuring unit ª Ready for remote reading
with a two litre cyclic volume designed to accurately ª OFGEM approved
meter volumes in all natural gas and LPG applications. ª Part of established “U”
The U16 uses two of the same measuring units to series Diaphragm meter
cope with larger flows of the same second and third range
family gases. ª BS EN1359 Compliant
ª BS EN ISO 9001 and
PRINCIPLE OF OPERATION
BS14001 Certified Factory
The U6, SC6 and U16 meters are positive displacement
diaphragm gas meters with twin chamber measuring
units. These chambers are fitted with a gas-tight
diaphragm which is driven by the differential pressure
between the inlet and outlet of the meter.

SPECIFICATIONS knowledge to shape your future 39


PRINCIPLE OF OPERATION (Cont’d) Fixed Stroke Measuring Unit
The gas enters the diaphragm chamber The achievement of a fixed stroke
via a radial valve, which is designed mechanism is the result of precision and
to slide cleanly under all operating high quality workmanship, and eliminates
conditions, and is assembled from self- the need for adjustment within the meter.
lubricating materials. Gas enters one side This confines all registration adjustment
of the diaphragm pan while the other side to the accessible change wheels situated
is exhausting through a separate port on behind index.
the valve. When one side if the chamber
is full, the valve moves on to the next Integral reinforcing Meter Bar
position, allowing gas to fill the exhausted (Steel case U6/G4 Models).
side. The radial valves are continuously The integral meter bar provides permanent
in motion, controlled by a fixed tangent and accurate spacing of connection
which transfer the reciprocating motion centres and protects the meter case from
through the gearbox to the index. bending and torsion stresses by reinforcing
pipe connections. This is an advantage
Design For Life under all circumstances, and essential
The design features combine to give a when connecting to rigid pipework in
meter with very large turndown ratio, domestic installations.
high accuracy at low flow rates, and no
maintenance requirements, all of which Case Assembly Strength
provide an accurate and economical The extreme strength of the case joint
way of measuring both constant and is achieved by rolling the lowercase edge
fluctuating gas loads. over the upper case compressing the
flanges into contact with a sealant applied
Construction for Reliability between the faces. This forms a joint
The models available are constructed which is both gas tight and fire resistant,
using a modern automated process complying with the requirements of
with a capacity of more than one million BS EN 1359.
meters per year.
The extensive use of automation and
precision engineering materials offers
greater accuracy and increased reliability.
Significant developments have allowed
the number of components to be
significantly reduced and the quality of
the meter enhanced.

Long Life Synthetic Diaphragms


The material used coupled to the well
proven operational design, combine
to give excellent stability and accuracy
over the whole life of the meter. This is
demonstrated by the use of this material
since the late 1970’s, with excellent
results.
Meter Engine, U6 meter,
and Diaphragm in pan

40 U6, SC6 AND U16


New Index Design SC6
The new U6 and U16 Pulse Ready index The SC6 shares the same quality of
has been developed to simplify manufacture manufacture and design as the U6,
and maximise flexibility for the meter owner. but has a plastic case and top viewing
index, for better resistance to corrosion
and easier readability when used in
“Semi - concealed” applications. Indeed,
there are many installations where the
SC6 may spend much of its working life
immersed in water.

U16/MDA16 Large Residential Meter


The U16 is designed for use in larger
U6 homes and small commercial units. Two
The U6/G4 is designed to meter gas of the two-litre fixed stroke measuring
usage from pilot light to central heating units are combined to make the U16 is
loads. The U6 is compact, with connection a cost-effective method of metering,
centres at 152 mm (6”), highly reliable, offering excellent turndown and low
and built to the highest quality standards. pressure drop.

PRESSURE DROP & ACCURACY


mbar
+2% 1. 2

net 0. 8

-2% 0. 4

0 3 6 m/3h

mbar
+2% 1. 2

net 0. 8

-2% 0. 4

0 8 16 m/3h

U6, SC6 AND U16 41


Dimensions and weights
Connection Connection
Meter Capacity Depth Width Height Connection
separation Distance
Model (m3/h) (mm) (mm) (mm) Size
(mm) (mm)
1”Male
U6 6 197 230 270 152.4 85
BS746
¾” /1”
SC6 6 170 240 302 - -
BS21
1¼”Male
MDA16 16 346 343 283 152.4 160
BS746

Working Pressure Cyclic


Meter Weight
Pressure Absorbtion Volume
Model (kg)
(mbar) (mbar) (l)
U6 75 1.22 2 3.5
SC6 50 1.3 2 3.8
MDA16 75 1.22 4 9.5

CS CD

W D

42 UK-00001.0-EN-03.04
SPARKLOG
Datalogger

The SparkLog data logger offers new ways to multi-energy


metering, combining Electricity, Gas and Water.

SPARKLOG IS UNIVERSAL SPARKLOG IS COMPATIBLE


SparkLog has 4 pulse inputs each The communication protocol is based on
individual programmable for energy / fluid IEC1107 protocol with the enhancements
media. Configured as a stand-alone device of the German VDEW/VDN specification,
it operates independent from mains supply supported by most of the AMR systems
on its internal Lithium battery up to eight
years and therefore well adopted to Gas SPARKLOG GOES OBIS/EDIS
and Water meters. For the identification of its measuring
values SparkLog relays on OBIS/EDIS
SPARKLOG IS A TEAM PLAYER identification for display and IEC1107
For remote meter reading purposes, protocol codes.
SparkLog and Sparkline modems build
up a perfect team. The proven Sparkline SPARKLOG FOR OPEN MARKETS
technology makes up the basis for a long SparkLog has its roots in the Electricity
term reliable communication. This modular metering business and has implemented
concept lets the user choose the right all the functions identified to survive in the
communication technology for the deregulated energy markets. Equipped
metering point at any time - right from the with Sparkline communication technology
beginning or later on without interruption additional meters can be easily connected,
and without breaking any certification e.g. ACE6000 DC3, DC4, SL7000
seals. This insures maximum flexibility
and secures investments.

SPECIFICATIONS knowledge to shape your future 43


MAIN FEATURES: ª Channel specific end of day times
ª Approval of the German PTB according (12:00 pm or 06:00 am)
PTB-A-50.7 for Electricity, Gas and Water ª Verification Logbook
ª 4 Channel, multi energy data logger ª Operation Logbook
ª 4 Channel load profile recorder ª 8 year battery operation
(stand alone version only)
ª 2 Maximum demand registers per
channel: ª 1 year backup battery operation when
1 maximum @ measuring period 1 powered with Sparkline modem
1 maximum @ measuring period 2 ª Optical Port according. IEC1107
with 15 end of billing registers (EOB) each ª Sparkline GSM/GPRS, PSTN, ISDN
ª 1 Total energy register per channel with modem as option
15 end of billing registers (EOB) ª Universal mounting adapter (as option)

SparkLog-PSTN operating example

44 SPARKLOG
Features
Device type Multi-energy data logger with 4 pulse inputs and Sparkline
communication adapter (option)
Power supply - Battery (without Sparkline) Battery life time > 8 years
- with Sparkline: auto ranging power supply (85..250 VAC; 120..250
VDC) and build in backup battery
Operating temperature -10°C up to +50°C
Storage temperature -10°C up to +70°C
Housing Housing according DIN 43861-2 for installation on meter terminal
cover, standard DIN meter cabinets, DIN rail (optional) or universal
installation adapter (optional)

Register and Load profile recorder


Energy register 1 total register per channel with 15 end of billing (EOB) registers
Load profile recorder capacity > 400 days @ 60 min interval
capacity > 100 days @ 15 min interval
Measuring period 1 -15 or 60 minutes; 1 maximum demand register; 15 EOB registers
Measuring period 2 -1440 minutes (24); 1 maximum demand register; 15 EOB registers
Day change Programmable (channel specific) 12:00 PM or 06:00 AM
Time basis Crystal
Display 7 segment LC Display with symbols
Other Verification Logbook - Operation Logbook

I/O Functions
Pulse inputs 4 Reed; 2 of it programmable for Reed or S0 (EN 62053-31 Mode A)
Pulse output 1 pulse output (EN 62053-31 Mode A)
Measuring period output 1 pulse output (EN 62053-31 Mode A)
Other inputs DCF77 input for RTC synchronization

Communication
Interfaces Optical port according EN 62056-21 (ex. IEC1107)
Communication speed <= 19200 Baud
Protocol EN 62056-21 Mode C (ex. IEC1107)
plus extensions according VDEW/VDN requirements version 2.1
Identification system OBIS according EN 62056-61 and EN 13357 (Gas)
Modem Optional with integrated Sparkline modem GSM,GPRS, PSTN
and ISDN

SparkLog
LC-Display

SPARKLOG 45
46 ID-Nr.: ACT-E-5059-01
ACD G10
and G16
Diaphragm Meters - High Accuracy Commercial Meters

Our new generation Itron Diaphragm G10-G16 KEY BENEFITS


meters combine accuracy and long life in a very ª Ready for remote reading
compact casing. Through our proven know-how and data management
in gas measurement, combined with the use of ª Long-term accuracy and
modern engineering and production techniques, reliability
Itron has developed this smaller size, highly ª Robust, maintenance-free
accurate meter, ensuring reduced shipping costs, meter
and easier handling and simplified installation. ª Compact design
Our range of ACD G10-G16 meters are designed ª MID approved
for commercial use for gas suppliers and gas ª High resistance to
utilities worldwide. corrosion

APPLICATION OPERATING PRINCIPLE


The ACD diaphragm meters are used for The movement of the diaphragm is
applications requiring high precision and caused by the pressure difference
large rangeability at low pressure (below between the inlet and the outlet of the
1 bar gauge). meter. The reciprocal filling is controlled
They are supplied in two versions - by means of two sliding valves.
a compact and a standard version (single This oscillating movement is transformed
and two pipe). Due to the volumetric into a rotational one and is mechanically
principle of the diaphragm meters, its transmitted to the totalizer through a
metrology is not influenced by installation magnetic coupling or a stuffing box.
conditions.
They are designed for use with natural
gas, manufactured gas and other non-
corrosive gases. The ACD diaphragm
meters are approved for fiscal use.

SPECIFICATIONS knowledge to shape your future 47


TYPICAL ERROR CURVE
Error in % EC Accuracy Error in % % Flow rate (m3/h)
4
3
2
1
0
-1
-2
-3
-4
0 10 20 30 40 50 60 70 80 90 100

PRESSURE LOSS CURVE


mbar ACD G10 ACD G16
3.00
2.50
2.00
1.50
1.00
0.50
0.00
0 2 4 6 8 10 12 14 16 0 5 10 15 20 25
Pressure loss Air (1.2 kg/m3) Pressure loss Natural Gas (0.8 kg/m3) Flow rate (m3/h)

CONSTRUCTION ➋ A steel casing fitted with one or two


connections
➌ A magnetic coupling or stuffing box
transmits the movement of the
➌ ➍ measuring unit to the totalizer
➍ A totalizer is available in different
versions depending on the application
ª “e” series: electronic index for
➋ a 2-way wired/wireless M-Bus
➊ communication and with optional
electronic temperature conversion.
ª “c” series: mechanical index
equipped with a Cyble target for
retrofittable AMR communication
systems.
The ACD G10-G16 meters contain four This Itron standardised meter
main parts: interface allows the adaptation
of different Cyble modules as a
➊ A measuring unit communication device.
with:
ª “o” series: mechanical index
ª Four measuring available with a permanent magnet
chambers. in an index drum. Can be refitted
ª Two sliding valves. with a Low Frequency pulse
ª An outlet pipe. transmitter (Reed switch).

48 ACD G10 AND G16


Technical Specifications
Gas Type Natural Gas, air, propane, butane, nitrogen and all non-corrosive gases
Cyclic Volume 5 dm³
Temperature Range Ambient: -25°C to +55°C
Gas: -25°C to +55°C
Storage: -40°C to +70°C
Maximum Operating Compact version: 0.5 bar
Pressure Standard version: 0.5 bar (1 bar optional)
Measuring Range G10: Qmin 0.10 m3/h
Qmax 16 m3/h
G16: Qmin 0.16 m3/h
Qmax 25 m3/h
Accuracy Class 1.5
Approval MID (04/22/EC) module B & D
Metrology In accordance with the EN1359:1998/A1:2006 and MID
Maximum permissible errors are +/-3% from Qmin to 0.1 Qmax
and +/-1.5% from 0.1 Qmax to Qmax.
Starting Flow Rate Typical value: < 8 dm3/h
Totalizer IP54
UV resistant cover
Fitted with a reflecting disc on the first drum to facilitate periodical checks
Customised name plate: bar code, customer serial number or logo
Magnetic Coupling The meter is equipped as standard with a magnetic coupling
Stuffing Box As an alternative a stuffing box can be also installed
Connections Single pipe or 2 pipe connections
From DN32 to DN50 depending on the G-size
Other connections are available on request
Backrun Stop Prevents the meter from running backwards in case of tampering
RPF (Resistant Power According to PRS11 (< 1.2)
Factor)
Materials Casing: aluminium-coated sheet steel
Measuring unit body: polyacetal (POM)
Diaphragms: polyester fabric coated with NBR-ECO
Distribution valves and grid: phenol resin
Colour Light grey RAL7035

Options
Thermowell The meters can be fitted with a thermowell to
allow electronic temperature compensation.
A second thermowell for reference
mesurements is available on special request
High Temperature The meters can be delivered in a HTL version
Loading (HTL) following EN1359 PN0,1
Pressure Tapping This device allows the gas pressure to be Thermowell fitted onto
measured at a reference point. an ACD standard

ACD G10 AND G16 49


TOTALIZER FEATURES ª High accuracy error curve correction
With the ECO series, Itron offers a ª Optional temperature conversion
complete portfolio to address today’s ª Built-in 2-way wired/wireless M-Bus
and future energy resource and communication
environmental challenges. ª Safe data transmission with AES
“e” series ª Tamper protection and detection
Supporting the prevailing European
Communication “c” series
Standards and ensuring interoperability Smart ready, allowing for future AMR
This smart meter equipped with an capabilities
electronic index is designed to facilitate Itron’s latest-generation mechanical
integration into wired and wireless fixed index meter comes standard with our
networks and has built-in communications Cyble™ target, and can be upgraded in
capabilities which detects reversed the field to implement AMR and enable
operation, magnetic tampering and remote reading via different
backflow. communication technologies.

Building Blocks of Itron’s “e” series

ACD Electronic,
M-Bus,
index,
G10 optical
wired,
wireless
G16 pulse

Base Meter Index Communication


Totalizer characteristics “e” series Module

Meter Size G10 / G16


European Metrological Approval N° DK-0200-MI002-020
(04/22/EC - Module B)
Temperature Range Temperature (converted):
-10°C to +55°C (-25°C to +55°C optional for G10)
Storage temperature:
-40°C to +70°C (> 55°C for up to 4 hours)
ATEX Approval II 2G Ex ib IIB T3
Relative Humidity Maximum 93% non-condensing between -25°C and +55°C
Display LCD with 9 digits (3 decimals)
M-Bus Interface 300bps / 2400 bps / one bus load, wireless or dongle
(up to four bus loads)
Battery Lithium battery with an average lifetime of min. 15 years
under reference conditions
Standards EN12405-1: 2007-08, Directive 2004/108/EC (EMC) and OIML
D11 (EMC), NTA8130-May 2007, DSMR V2.2+ (Netherlands)
Serial Bus M-Bus slave (wired: EN13757-2/3, wireless: EN13757-4)
Customer Port IR service interface (EN62056-21)
Mechanical Environment M1
Electronical Environment E2

50 ACD G10 AND G16


ª Smart reading possible with additional “o” series
modules Retrofit enabling smart upgrades to
ª Can be retrofitted on site without existing meter park
recalibrating the meter
The “o” series addresses traditional
ª Reliable of an electronic switch meters with a mechanical index, already
(no wear or bouncing) installed in the field, to minimize stranded
ª Proven, tested design backed by assets when AMR/AMI is required.
20 years’ experience LF transmitters - via a Reed switch - and
ª Protection against magnetic tampering a Pulse RF radio module transform
pulses into transmittable data.

Building Blocks of Itron’s “c” series

ACD Mechanical AnyQuest &


index, EverBlu Cyble,
G10 inductive Cyble M-Bus,
G16 pulse Cyble Sensor

Base Meter Index Communication


Totalizer characteristics “c” series Module

Meter Size G10 / G16


European Metrological Approval N° DE-07-MI002-PTB013
(04/22/EC - Module B)
Display Mechanical index with 8 drums (2 decimals)
Transmission Rate 0.1 m3 / rotation
Transmission System CybleTM target
Mechanical Environment M2
Electronical Environment E2
Building Blocks of Itron’s “o” series

ACD Mechanical
index, AnyQuest
G10 magnetic & EverBlu
G16 pulse Pulse

Base Meter Index Communication


Totalizer characteristics “o” series Module

Meter Size G10 / G16


European Metrological Approval N° DE-07-MI002-PTB013
(04/22/EC - Module B)
Display Mechanical index with 8 drums (2 decimals)
Pulse Generator Standard 0.1 m3 / pulse (optional 1 m3 / pulse)
Pulse Transmitter Retrofittable LF system, 12 Vdc max – 10 mA max. standard
0.1 m3/pulse.
Different versions: with 1m cable, terminal block or binder
plug (Double LF pulse transmitter)
Mechanical Environment M2
Electronical Environment E2

ACD G10 AND G16 51


E Weight

52
G Qmax Qmin Cyclic DN Threads Pmax Pmax Pressure A B C D mm kg
Model Volume HTL Loss (Air)
Size m3/h m3/h dm3 mm Standard bar bar mbar mm mm mm mm “e” “c & o” “e” “c & o”
series series series series
ACD Compact: 2 pipe version
1 G10 16 0.10 5 32 G1¾” A ISO228-1 0.5 0.1 1.9 250 310 71 325 204 189 4.4 4
2 G10 16 0.10 5 32 MFIT001 0.5 0.1 1.9 250 310 71 325 204 189 4.4 4
Dimensions and Weight

3 G10 16 0.10 5 40 G2” A ISO228-1 0.5 0.1 1.9 250 310 71 325 204 189 4.4 4

ACD G10 AND G16


4 G16 25 0.16 5 40 G2” A ISO228-1 0.5 0.1 2.9 250 310 71 325 204 189 4.4 4
ACD Standard: 2 pipe version
10 G10 16 0.10 5 32 G1¾”A ISO228-1 0.5 0.1 1.9 280 328 85 382 206 191 5.3 4.9
11 G10 16 0.10 5 40 G2”A ISO228-1 0.5 0.1 1.6 280 324 85 382 206 191 5.3 4.9
12 G10 16 0.10 5 40 G2”A ISO228-1 0.5 0.1 1.6 290 349 85 382 206 191 5.3 4.9
13 G10 16 0.10 5 40 G2”A ISO228-1 0.5 0.1 1.6 300 353 85 382 206 191 5.3 4.9
14 G16 25 0.16 5 32 G1¾”A ISO228-1 0.5 0.1 2.9 280 328 85 382 206 191 5.3 4.9
15 G16 25 0.16 5 40 G2”A ISO228-1 0.5 0.1 2.7 280 324 85 382 206 191 5.3 4.9
16 G16 25 0.16 5 40 G1½” BS Withworth 0.5 0.1 2.7 280 328 85 382 206 191 5.3 4.9
17 G16 25 0.16 5 40 G2”A ISO228-1 0.5 0.1 2.7 300 353 85 382 206 191 5.3 4.9
18 G16 25 0.16 5 50 MFIT001 0.5 0.1 2.7 280 327 85 382 206 191 5.3 4.9
19 G16 25 0.16 5 50 Flange ISO PN10 0.5 0.1 2.7 280 417 123 396 206 191 9.0 8.6
20 G16 25 0.16 5 40 2” BS746 0.5 0.1 2.7 280 347 85 382 206 191 5.3 4.9
ACD Standard: Single pipe version
30 G10 16 0.10 5 40 G2¾” ISO228-1 0.5 0.1 1.9 - 370 85 382 206 191 5.8 5.4
31 G16 25 0.16 5 40 G2¾” ISO228-1 0.5 0.1 2.9 - 370 85 382 206 191 5.8 5.4
DN E
DN E C
DN E A
A C
C
B

B
D D D

ACD Compact: Two Pipe version ACD Standard: Two Pipe version ACD Standard: Single Pipe version

ACD G10 AND G16


53
54 GA-ACD-G10-G16-EN-V3.0-2011.08
G25 and G40 KEY BENEFITS
ª Ready for remote reading
Diaphragm Meters and data management
ª Long-term accuracy and
Through decades of knowledge in the field of reliability
commercial and industrial diaphragm gas ª Very low pressure loss
meters, our G25 and G40 meter sizes combine ª Robust, maintenance-free
accuracy of measurement and long life in the meter
field. ª Large cyclic volumes

APPLICATION OPERATING PRINCIPLE


The G25-G40 diaphragm meters are The movement of the diaphragm is
used for applications requiring high caused by the pressure difference
precision and large rangeability at low between the inlet and the outlet of the
pressure (below 1 bar gauge). meter. The reciprocal filling is controlled
Due to the volumetric principle of the by means of 2 sliding valves.
diaphragm meter, its metrology is not This oscillating movement is transformed
influenced by installation conditions. into a rotational one and is mechanically
They are designed for use with natural transmitted to the totalizer through a
gas, manufactured gas and other non- magnetic coupling or a stuffing box.
corrosive gases.
The G25-G40 diaphragm meters are
approved for fiscal use.

SPECIFICATIONS knowledge to shape your future 55


TYPICAL ERROR CURVE
G25 (Two Pipe DN50) G40 (Two Pipe DN80)
Error in % Error in %
4
3
2
1
0
-1
-2
-3
-4
0 10 20 30 40 0 10 20 30 40 50 60
EC Accuracy Error in % Flow rate (m3/h) EN1359 and MID Error in % Flow rate (m3/h)

PRESSURE LOSS CURVE


mbar G25 G40
3.00
2.50
2.00
1.50
1.00
0.50
0.00
0 10 20 30 40 0 10 20 30 40 50 60
Pressure loss Air (1.2 kg/m3) Pressure loss Natural Gas (0.8 kg/m3) Flow rate (m3/h)

CONSTRUCTION ➋ A steel casing where 1 or 2 connectors


are fitted.
Working Principle ➌ A magnetic coupling or a stuffing box
transmits the movement of the
measuring unit to the totalizer.
➍ A totalizer is available in different
versions depending on the application
ª “e” series: electronic index for a 2-way
wired/wireless M-Bus communication
and with optional electronic
temperature conversion (only G25).
ª “c” series: mechanical index
equipped with a Cyble target for
retrofittable AMR communication
A diaphragm meter is
s made of systems. This Itron standardised
four main parts: meter interface allows the adaptation
➊ The measuring unit
of different Cyble modules as a
communication device.
mainly consisting in:
ª “o” series: mechanical index
ª Four measuring
available with a permanent magnet
chambers. in an index drum. Can be refitted
ª Two sliding valves. with a Low Frequency pulse
ª An outlet pipe. transmitter (Reed switch).

56 G25 AND G40


Technical Specifications
Gas Type Natural Gas, air, propane, butane, nitrogen and all non-corrosive gases
Cyclic Volume G25: 20 dm³
G40: 30 dm³
Temperature Range Ambient: -25°C to +55°C
Gas: -25°C to +55°C
Storage: -40°C to +70°C
Maximum Operating 0.5 bar (1 bar optional)
Pressure
Measuring Range G25: Qmin 0.25 m3/h
Qmax 40 m3/h
G40: Qmin 0.4 m3/h
Qmax 65 m3/h
Accuracy Class 1.5
Approval MID (04/22/EC) module B & D
Metrology In accordance with the EN1359:1998/A1:2006 and MID
Maximum permissible errors are +/-3% from Qmin to 0.1 Qmax
and +/-1.5% from 0.1 Qmax to Qmax.
Totalizer IP54
UV resistant cover
Fitted with a reflecting disc on the first drum to facilitate periodical checks
Customised name plate: bar code, customer serial number or logo
Magnetic Coupling The meter is equipped as standard with a magnetic coupling
Stuffing Box As an alternative a stuffing box can be also installed
Connections Single pipe or 2 pipe connections
From DN40 to DN80 depending on the G-size
Vertical connections for the G25, vertical or horizontal for the G40
Other connections are available on request
Backrun Stop Prevents the meter from running backwards in case of tampering
Materials Steel sheet, drawn or welded depending on the G-size.
The use of a powder-coated painting guarantees long term protection
against corrosion.
All the casings are of a screw type to allow easy maintenance on the
meter – no crimped casing
Colour Light grey RAL7035

Options
Thermowell The meters can be fitted with a thermowell
to allow electronic temperature compensation.
A second thermowell for reference
mesurements is available on special request
High Temperature The meters can be delivered in a HTL
Loading (HTL) version following EN1359 PN0,1
This device allows the gas pressure to be Thermowell fitted onto
Pressure Tapping
measured at a reference point. an ACD standard

G25 AND G40 57


TOTALIZER FEATURES ª High accuracy error curve correction
With the ECO series, Itron offers a ª Optional temperature conversion
complete portfolio to address today’s ª Built-in 2-way wired/wireless M-Bus
and future energy resource and communication
environmental challenges. ª Safe data transmission with AES
“e” series ª Tamper protection and detection
Supporting the prevailing European
Communication “c” series
Standards and ensuring interoperability Smart ready, allowing for future AMR
This smart meter equipped with an capabilities
electronic index is designed to facilitate Itron’s latest-generation mechanical
integration into wired and wireless fixed index meter comes standard with our
networks and has built-in communications Cyble™ target, and can be upgraded in
capabilities which detects reversed the field to implement AMR and enable
operation, magnetic tampering and remote reading via different
backflow. communication technologies.

Building Blocks of Itron’s “e” series

Electronic,
M-Bus,
index,
G25 optical
wired,
wireless
pulse

Base Meter Index Communication


Totalizer characteristics “e” series Module

Meter Size G25


European Metrological Approval N° DK-0200-MI002-018
(04/22/EC - Module B)
Temperature Range Temperature (converted):
-10°C to +55°C (-25°C to +55°C)
Storage temperature:
-20°C to +60°C (> 55°C for up to 4 hours)
ATEX Approval II 2G Ex ib IIB T3
Relative Humidity Maximum 93% non-condensing between -25°C and +55°C
Display LCD with 9 digits (3 decimals)
M-Bus Interface 300bps / 2400 bps / one bus load, wireless or dongle
(up to four bus loads)
Battery Lithium battery with an average lifetime of min. 15 years
under reference conditions
Standards EN12405-1: 2007-08, Directive 2004/108/EC (EMC) and OIML
D11 (EMC), NTA8130-May 2007, DSMR V2.2+ (Netherlands)
Serial Bus M-Bus slave (wired: EN13757-2/3, wireless: EN13757-4)
Customer Port IR service interface (EN62056-21)
Mechanical Environment M1
Electronical Environment E2

58 G25 AND G40


ª Smart reading possible with additional “o” series
modules Retrofit enabling smart upgrades to
ª Can be retrofitted on site without existing meter park
recalibrating the meter
The “o” series addresses traditional
ª Reliable of an electronic switch meters with a mechanical index, already
(no wear or bouncing) installed in the field, to minimize stranded
ª Proven, tested design backed by assets when AMR/AMI is required.
20 years’ experience LF transmitters - via a Reed switch - and
ª Protection against magnetic tampering a Pulse RF radio module transform
pulses into transmittable data.

Building Blocks of Itron’s “c” series

Mechanical AnyQuest &


G25 index, EverBlu Cyble,
inductive Cyble M-Bus,
G40 pulse Cyble Sensor

Base Meter Index Communication


Totalizer characteristics “c” series Module

Meter Size G25 / G40


European Metrological Approval N° DE-10-MI002-PTB004
(04/22/EC - Module B)
Display Mechanical index with 8 drums (2 decimals)
Transmission Rate 0.01 m3 / rotation
Transmission System CybleTM target
Mechanical Environment M1
Electronical Environment E2
Building Blocks of Itron’s “o” series

Mechanical
G25 index, AnyQuest
magnetic & EverBlu
G40 pulse Pulse
Totaliser with
LF “cable”
Base Meter Index Communication
Totalizer characteristics “o” series Module

Meter Size G25 / G40


European Metrological Approval N° DE-10-MI002-PTB004
(04/22/EC - Module B)
Display Mechanical index with 8 drums (2 decimals)
Pulse Generator Standard 0.1 m3 / pulse (optional 1 m3 / pulse)
Pulse Transmitter Retrofittable LF system, 12 Vdc max – 10 mA max. standard
0.1 m3/pulse.
Different versions: with 1m cable, terminal block or binder
plug (Double LF pulse transmitter)
Mechanical Environment M1
Electronical Environment E2

G25 AND G40 59


E Weight

60
G Qmax Qmin Cyclic DN Threads Pmax Pmax Pressure A B C D mm D kg
Model Volume HTL Loss (Air)
Size m3/h m3/h dm3 mm Standard bar bar mbar mm mm mm mm “e” “c & o” mm “e” “c & o”
series series series series
G25: 2 Pipe version
1 G25 40 0.25 20 50 G2½” A ISO228-1 1 0.1 2.4 335 443 138 457 304 289 13.7 13.3

G25 AND G40


2 G25 40 0.25 20 40 G2” A ISO228-1 1 0.1 2.4 335 443 138 457 304 289 13.7 13.3
Dimensions and Weight

3 G25 40 0.25 20 50 G2½” A ISO228-1 1 0.1 2.4 400 534 138 457 304 289 13.9 13.6
G25: Single Pipe version
4 G25 40 0.25 20 50 ISO PN10 1 0.1 2.4 – 469 138 457 304 289 14.8 14.4
G40: 2 Pipe version - vertical drawn
1 G40 65 0.4 30 65 ISO PN10 1 0.1 1.7 430 661 185 612 399 384 42.4 42.0
2 G40 65 0.4 30 80 ISO PN10 1 0.1 1.7 430 661 185 612 399 384 42.4 42.0
3 G40 65 0.4 30 80 ISO PN10 1 0.1 1.7 500 719 185 612 399 384 41.4 41.0
4 G40 65 0.4 30 65 ISO PN10 1 0.1 1.7 510 719 185 612 399 384 41.4 41.0
5 G40 65 0.4 30 80 ISO PN10 1 0.1 1.7 510 719 185 612 399 384 41.4 41.0
G40: 2 Pipe version - horizontal welded
6 G40 65 0.4 30 65 ISO PN10 0.5 0.1 1.7 570 420 175 494 384 369 634 52.4 52.0
7 G40 65 0.4 30 80 ISO PN10 0.5 0.1 1.7 570 420 175 494 373 358 634 52.4 52.0
G40: Single pipe version
8 G40 65 0.4 30 65 ISO PN10 1 0.1 1.7 697 185 612 399 384 46.4 46.0
9 G40 65 0.4 30 80 ISO PN10 1 0.1 1.7 697 185 612 399 384 46.4 46.0
A DN C
A DN DN
A
D

DN

B
B
D E

F
B
G25 Two Pipe vertical drawn
DN C

D D
B

C
E

E
E

D E
G40 Two Pipe G40 Two Pipe G40 Single Pipe G25 Single Pipe vertical drawn
horizontal welded vertical drawn vertical drawn

G25 AND G40


61
62 GA-G25-G40-EN-V3.0-2011.08
G65 and G100
Diaphragm Meters

The diaphragm meters G65 and G100 are KEY BENEFITS


designed for industrial applications. The design ª Long term accuracy and
is based on high measuring accuracy and a long reliability
lifetime and are maintenance free. ª Robust, maintenance free
This performance is made possible through the meter
principle of two measuring chambers, which are ª MID approved
driven by the pressure of the gas. The measured ª Wide measuring range
volume is displayed on a numeric totalizer. ª Low pressure loss

TECHNICAL DESIGN
Totaliser
A direct or indirect driven register, depending on the
type of coupling between the measuring unit and the
index box, indicates the passed volume of gas.
Both index box-constructions are designed in such a Totaliser with Cyble target
way that it’s almost impossible to access the registers
without damaging them.
Measuring unit
The measuring unit consists of two chambers with
synthetic and gas-tight diaphragms, which is moved
by the differential between the inlet and outlet pressure.
A transmission gear and a magnetic coupling / stuffing
box transfer the reciprocating motion to the mechanical
index.
The unit is built in a robust steel coated casing, either
drawn or welded. Measuring unit

SPECIFICATIONS knowledge to shape your future 63


Technical Specifications
Measuring Range G65 Qmin 0.65 m3/h Qmax 100 m3/h
G100 Qmin 1.00 m3/h Qmax 160 m3/h
European Metrological Approval N° DE-10-MI002-PTBXXX
Approval (04/22/EC)
Temperature Range Operation temperature: -10°C to +40°C.
Storing temperature: -40°C to +70°C.
Maximum Operating 500 mbar
Pressure
High Temperature The meter can be delivered, as an option, with a HTL version PN0.1
Loading (HTL)
Double and single flange connections, DN80 for G65 and DN100 for
Connections
G100
Totalizer Equipped with a magentic coupling, as standard. As an option, a
stuffing box version is also available
8-digit index with IP 54 protection
UV resistant cover
Fitted with a reflecting disc in the first drum to facilitate preiodical checks
Reverse flow device The meter is equippped with a device which prevents registration of
reverse flow
Housings Welded (G65 single pipe & G100) or Drawn (G65 double pipe) with
powder coating
Colour The meter is equipped as standard with a magnetic coupling
As an alternative a stuffing box can be also installed

ACCURACY
In accordance with the EC and OIML standards.
In line with EC standards, the tolerance of acceptation is +/-3 % from Qmin to 0.2
Qmax and +/-1.5% from 0.2 Qmax to Qmax.

Typical error curve


Error in %
4
3
2
1
0
-1
-2
-3
-4
0 10 20 30 40 50 60 70 80 90 100
EC Accuracy Error in % % Flow rate (m3/h)

Every meter undergoes a 100% inspection for function, accuracy and safety.
All meters are EN1359 compliant and have DVGW approval.

64 G65 AND G100


LF pulse-emitter
Meter versions with the sardine index
box are standard equipped with a
LF pulse-emitter.
1 pulse is 0.1m3 (G65) or 1 m3 (G100).
The 4 pins male-connector is fixed in a
“D”-hole in the index box. The female Totaliser with LF “cable”
contra- connector is supplied with each
meter.
The RF1 index box is available with a
permanent magnet in one of the index
drums as standard and can be refitted
with a pulse transmitter (reed switch).

Totaliser with Double LF “Binder plug”


G65-G100 VERTICAL VERSION
Dimensions and Technical Data
Nozzle Q min Qmax Vol. Pmax Flange a b c d h Weight
Type
Type m3/h m3/h dm3 bar DN mm mm mm mm mm kg
G65 Drawn 0.65 100 55 0.5 80 500 700 217 445 687 48
G65 Drawn 0.65 100 55 0.5 80 640 840 216 445 790 52
G65 Welded - EP 0.65 100 55 0.5 80 N/A 700 216 436 737 71
EP = Single nozzle.
b d b
d
c
c a
h
h

G65b Double pipe Drawn (500) Single Pipe Welded

Single Pipe
Double Pipe
welded type
drawn type

G65 AND G100 65


G65-G100 VERTICAL VERSION
Dimensions and Technical Data EP = Single nozzle.
Nozzle Q min Qmax Vol. Pmax Flange a b c d h Weight
Type
Type m3/h m3/h dm3 bar DN mm mm mm mm mm kg
G100 Welded 1 160 123 0.5 100 675 894 257 532 885 105
G100 Welded 1 160 123 0.5 100 710 894 257 532 885 105
G100 Welded - EP 1 160 123 0.5 100 N/A 894 257 532 920 113
d b d b
c a c a

h
h

G100 Double Pipe Welded (675) G100 Double Pipe Welded (710)

G65 HORIZONTAL VERSION


This version, which has also the same G65 internal parts as the other G65 meters, is
standard equipped with magnet coupling and RF1-Index box.
Dimensions and Technical Data
Nozzle Q min Qmax Vol. Pmax Flange a b c d hl h Weight
Type
Type m3/h m3/h dm3 bar DN mm mm mm mm mm mm kg
G65 Welded 0.65 100 55 0.5 80 680 654 212 432 400 626 69
d a
c b

Information to be specified
when ordering:
ª Nature of gas
ª Measuring range (G65 or G100)
h

ª Specific marking (serial number,


h1

customer logo, bar code)


ª Maximum working pressure
G65 horizontal version ª Version (horizontal or vertical)
ª Meter interaxis and connection type
OPTIONS ª Accessories and options
On request the following options
are possible
ª AMR/AMI solution: Totaliser pre-equipped with a Cyble target
ª Thermowell (second one for reference measuments on special request)
ª Other flange dimensions
ª Pressure tapping point
ª Retrofittable Low Frequency (LF) transmitter in different versions (Cable, Binder plug)
ª Counter flanges for both Double and Single Pipe versions

66 GA-G65-G100-EN-V2.0-2011.11
ANGus®
Natural gas quality analyzer

ANGus® is a natural gas quality analyzer for KEY BENEFITS


industrial purposes. ª Real-time measurement
It breaks new ground for applications needing of natural gas quality (Hs,
real-time monitoring of the main gas energetic Hi, SG, W, MN, %CO2)
properties. ª OIML R140 compliant
(accuracy class B on Hs)
ª Measurement period
APPLICATIONS
15 seconds
Natural gas quality varies a lot in the networks today.
ª Installation in industrial
This worldwide trend is mainly due to the development
ATEX hazardous areas
of the networks and their use in de-regulated markets,
zone 1 & 2
involving the increase of natural gas supply sources /
storages and fast switches from one source to another. ª Low maintenance
ª User-friendly integrated
As a result, these variations affect the combustion
interface with large
properties of the gas, leading to major concerns for
graphic display
industrial customers and utilities.
ª Large and flexible database
ANGus® provides an efficient solution to these problems
and can be used for two major application types: ª Extended communication
capabilities (2 analog
ª Energy metering and billing outputs, 2 digital outputs,
ª Industrial process safety and efficiency improvement 2 RS485 ports)
Real-time energy metering at the metering point allows
utilities to bill on a fairer basis and industrial customers
to better monitor their energy consumption.
On the other side, real-time monitoring of gas quality
is the key to optimise combustion in most industrial
processes, therefore improving their efficiency and
safety control.

SPECIFICATIONS knowledge to shape your future 67


TECHNICAL DATA

ANGus
Approvals
ª ATEX:
group II category 2(1)G device approved
for use in hazardous areas (zone 1)
Classification: Ex mb ia [ia] IIA T3
ª EC marking in compliance with directives:
network gas
89/336/EEC(EMC), 94/9/EC (ATEX) &
calibration gas 97/23/EC (PED)
vent
RS485 interface 2
ª Metrology:
RS485 interface 1 complies with OIML R140
4-20mA output 2 recommandations - “Measuring
4-20mA output 1
On-Off output 2
systems for gaseous fuel”
On-Off output 1 ª Approved for fiscal metering in France:
230V AC power supply
LNE type-examination certificate
N° LNE-15760 rev.0
DESCRIPTION
ANGus® provides real-time measurement Accuracy / performance
(every 15 seconds) of the following gas ª Class B according to OIML R140
properties: standard
ª Superior (Hs) and Inferior (Hi) heating ª See detailed characteristics in the table
values page 72
ª Wobbe index (W) ª Very low drift compatible with annual
servicing
ª Methane Number (MN)
ª Specific gravity (SG) Measurement technology
ª CO2 Molar fraction (%CO2) ª Inferential method based correlation
It uses an inferential analysing technology between thermal conductivity and CO2
based on correlation between several gas fraction
physical properties (thermal conductivity ª Robust stainless steel sensors block
and CO2 molar fraction). Accuracy stability assembly
is ensured by an auto-adjustment process ª Automatic adjustment on pure methane
on pure methane, making ANGus® nearly ensuring accuracy stability over time
maintenance-free. ª One year autonomy with a 1 litre
It is designed to operate in industrial cylinder (methane)
environments, offering IP65 protection
level and being certified for use in ATEX
hazardous areas.
Its integrated user’s interface with a large
graphic display and a 5-button keypad
makes it very easy to install and configure
in the field.
Moreover, ANGus® offers numerous
communication links and I/O ports,
making it highly adaptable and easy to
integrate in any customer’s system (local
or remote connection via modems). Sensors block assembly

68 ANGus®
Main display Display in graph format Display of all data recorded
in the database
Keypad and Display Alarms
ª Graphic display (resolution: 128 x 64 ANGus® manages the following alarms:
pixels) ª Internal sensor failure
ª 5-button keypad ª Measurement outside ANGus defined
ª All recorded and live values are range (Min, Max) for Hs, Hi, W, MN,
available on display SG, %CO2
ª Graphic function for gas property ª Gas pressure outside operating range
variations monitoring (Min, Max)
ª The main parameters can be set via ª Measurement outside customer’s
the keypad predefined thresholds (Min, Max) for
ª All displayed labels can be translated Hs, Hi, W, MN, SG, %CO2
into other languages ª Measurement variation higher than
ª Customer’s logo can be added on display customer-defined value for Hs, Hi, W, MN
Database ª Calibration stopped
ª Integrated database featuring 7 logs. ª Calibration discrepancy
ª Selection of data to be stored in ª Mains power supply outage
calendar logs (interval, daily and hourly) ª Internal power failure
ª Hourly log: 1400 to 8100 records ª Backup battery lifetime
ª Daily log: 290 to 1900 records
Power Supply
ª Monthly log: 72 records
ª Mains 230 VAC
ª Interval log: 2900 to 16000 records
ª Backup battery providing minimal
(with adjustable interval duration from 1
operation in case of mains power outage
to 60 minutes)
ª Events: last 1100 Configuration
ª Parameters: last 200 ª By keypad or by software
ª Calibrations: last 4000 ª Key-parameters protected by sealed
internal switch

Event Log in WinProGas Display in WinProGas

ANGus® 69
IN/OUT INTERFACES COMMUNICATIONS SYSTEM
Electrical Outputs The two RS485 ports cover a wide range
of uses:
ª 2 x 4-20mA analog outputs
• Transmission of one gas property ª Local connection to an energy
value per output among: Hs, Hi, W, measurement system (CORUS “Energy”)
SG, MN, %CO2 or a Remote Terminal Unit (RTU) or a
• Accuracy ±1% FS Digital Control System (DCS)
• External DC power supply needed ª Remote connection via modem
• Connection length up to 200m Modbus protocol compatibility allows
ª 2 On-Off outputs easy integration of the product in most
customers’ systems via fully configurable
• Fully configurable alarm re-transmission
address tables.
• Connection length up to 200m
WinProGas software enables local
Communication links operations (configuration, database
ª 2 RS485 ports reading) through the optical interface or
• Half-duplex (2 wires) slave configuration the RS485 ports.
• Compatible with MODBUS RTU Itron also offers a set of devices for remote
protocol communication (GSM, GPRS, Ethernet).
• Fully configurable address table for
MODBUS
• Baud rate: 1200 to 19200
• Connection length up to 200m
ª 1 x IEC 1107 compatible optical interface

Digital On-Off outputs connection to local systems


ATEX area 1/2 Safe area
Customer DCS/PLC
galvanic
insulation
l ≤ 200m

galvanic
insulation
l ≤ 200m

On-Off outputs

Analog outputs connection to local systems


ATEX area 1/2 Safe area
Customer DCS/PLC
galvanic
insulation
l ≤ 200m

galvanic
insulation
l ≤ 200m

(4-20mA analog outputs)

70 ANGus®
RS485: local connection to CORUS “Energy” and local systems
ATEX area 1/2 Safe area
ISB+ Customer DCS/PLC

l ≤ 200m

l ≤ 200m
OK

RS485: remote connection via FOCUS+ (GSM/GPRS modem)


ATEX area 1/2 Safe area GSM/GPRS

ANGus® FOCUS+ Data-collection software

Sampling
line ANGus®

Vent

To DCS,
calculator, or Calibration gas
communication
device Mains supply

Example of a connection set-up

Dimensions (mm)
309

215
154

O6

507 422

ANGus® 71
Technical Specifications
Accuracy ±1.0% of the measurement point (Hs, Hi, W, SG)
±0.2% mol on molar concentration (%CO2)
±2 points (MN) – in reference to AVL method
Stability over 1 Year ±0.5% of the measurement point (Hs, Hi, W, SG)
±0.1% mol on molar concentration (%CO2)
±1 points (MN)
Measurement Range Hs 8.9 – 13.1 kWh.m-3(n) (1)
Hi 8.1 – 11.9 kWh.m-3(n) (1)
W 10.5 – 15.7 kWh.m-3(n) (1)
MN 65 – 110 points (AVL method)
SG 0.55 – 0.75 (1)
%CO2 < 3% mol (Molar concentration)
Gas Supply Pressure: 1300 (±150) mbar (abs)
Consumption ≤ 3 l(n).h-1
Response Time Measurement period: 15 seconds
Response time 90%: 2 minutes (typ).
Level of Protection IP65 according to EN 60529
Ambient Temperature -20°C to +50°C
Calibration Automatic weekly adjustment on methane 4.5
(one year autonomy with a 1 litre cylinder)
Annual servicing
Power Supply Mains 230VAC
Max. power 150VA
Dimensions / Weight W x H x D = 507 x 309 x 154 mm - weight: 17 kg
Gas connections: threaded BSP G¼”
ATEX Can be installed in hazardous areas
II2(1)G approval: Ex mb ia [ia] IIA T3
(1) Under reference conditions (Tcombustion = 0°C, Pbase = 1.01325 bara, Tbase = 0°C)

Accessories
ª Sampling probe and conditioning line
ª Calibration line
ª Fixing plate for floor or wall mounting
ª ATEX barriers for connection to local
non-ATEX systems
ª Optical head
ª WinProGas configuration software
ª External modem (PSTN, GSM, GPRS,
etc.)
ª Turnkey solution sampling
ª Training (Operations and services)
Sampling probe (example)

72 GA-ANGus-EN-V2.0-2012.01
Quantometer
MZ KEY BENEFITS
ª High accuracy budget
Turbine Gas Meter
meter
ª Flow rate up to 2500 m3/h
MZ meters are flow meters. The flow of gas ª Pressure range up to
turns the turbine wheel, and thus the rotating 40 bar
speed of the turbine is proportional to the linear ª Equipped as standard with
speed of the gas. the cyble target
The movement is mechanically transmitted to ª Various options available:
the totaliser through a magnetic coupling. Low and high frequency
transmitters, thermowell,
oil pump, version for
APPLICATIONS
agressive gases, etc
MZ meters are designed to measure natural gas, and
various filtered, and non-corrosive gases.
They are used to measure low to medium and high
flow, at low or medium, or high pressure.
They have been especially designed for industrial use
and for secondary measurement.
The possibility of fitting various options such as the oil
pump or the PTFE coating version, means that they
are also suitable for use in heavy duty measurement.

SPECIFICATIONS knowledge to shape your future 73


DESCRIPTION
The MZ meter is composed of five main parts:
➊ a body part containing all the components
➋ a flow straightener to stabilise and accelerate the flow before the turbine wheel
➌ a measuring unit including the turbine wheel
➍ a magnetic coupling to transmit the movement of the turbine wheel to the totaliser
➎ a totaliser to register the measured gas
5

Quantometer MZ DN150,
Qmax: 1600 m3/h
Technical Specifications
Intrinsic Safety Approval L.C.I.E. 06 ATEX 6031 X
Flow Rate From 6 m³/h to 2500 m³/h
Nominal Diameters From DN 2" to 8", DN50 to DN200
Material Ductile iron
Compliant with the Pressure Equipment Directive 97/23/EC
Maximum Working Pressure Up to 40 bar depending on flanging
Temperature Range Ambient: -30°C to +60°C
Gas: -30°C to +60°C
Storage temperature: -40°C to +70°C
Metrology The tolerance of acceptation is +/-1.5% from Qmin to Qmax.

Typical calibration curve


Error in %
2.0
1.5
1.0
Error (%)

0.5
0.0
-0.5
-1.0
-1.5

0 20 40 60 80 100
% Max Flow

74 QUANTOMETER MZ
Totaliser:
ª 9-digit index to register a larger volume ª IP67 protection
on
ª 45° orientation for an easy reading ª UV resistant
ª Equipped as standard with the cyble cover
target: it allows the installation of the ª Unit: m3
cyble sensor at any time
Universal
ª Free-rotating totaliser totaliser fitted
ª Equipped with 1 built-in silicagel cartridge as standard
ª Fitted with a reflecting disc on the first with the
drum Cyble target

Transmitters Oil pump


➊ Cyble sensor: it can be delivered ➎ It lubricates the ball bearings in the
mounted onto the meter or installed measuring unit.
afterwards at any time. The oiling can be done even when the
The Cyble sensor is a bounce-free meter is under pressure. The oil
transmitter. It allows also the counting reservoir can be easily turned to fit
of eventual back flows. with vertical installed meters.
➋ Low Frequency (LF): two Reed Turbine wheel
switches are fitted as standard on the
whole range. ➏ This is the most important component
Anti-tampering (AT): this device is of the meter for achieving high
fitted as standard on the whole range. accuracy at low and high pressure.
➌ Medium Frequency (MF): one It can be made in aluminium for
transmitter is supplied as an option. the whole range or in polyacetal.
Depending on the maximum flow rate,
➍ High Frequency (HF): a transmitter is the blade of turbine wheel is oriented
supplied as an option on the whole
at 45° or 60°.
range, and it is fitted close to the
turbine wheel. Turbine wheel at 60° is used to avoid
over-speed of the wheel. When a
1 2 LF1 HF is requested, the wheel must
be in aluminium. For high pressure
use, or for measuring dirty gases, an
aluminium wheel is recommended.

MAGNET LF2 AT

4 3 5 6

Thermowell
➐ A thermowell can be installed as an option into the meter. It allows
the gas temperature to be measured at the reference point.
(Installation of a thermowell cannot be done into a meter equipped
with HF transmitter) 7

QUANTOMETER MZ 75
Volume converter Pressure tapping:
➑ It can be 8 This device allows the gas pressure to
installed directly be measured at the reference point.
onto the meter It is installed as standard.
thanks to a
mounting kit Measurement of aggressive gases:
A version with a PTFE (Teflon) coating, is
available, as an option.
The coating is applied on the internal
parts of the meter.

CHARACTERISTICS
A) Technical data sheet
Rangeability and pulse values With correction gears 32/40 (correction 0%)
DN Max Min Pressure 1 Imp Freq 1 Imp Freq 1 Imp Freq RPM
Flow Flow loss (mbar) LF & LF MF MF HF HF Qmax
l = 0.8 Cyble Qmax (dm3/ Qmax (dm3/ Qmax (Rot/
3
(mm) (m3/h) 3
(m /h) kg/m 3
(m /Imp) (Hz) Imp) (Hz) Imp) (Hz) min)
50 100 6 8.1 0.1 0.28 5.8947 4.71 0.00970 2864 14322
80 250 10 4.8 1 0.07 23.07692 3.01 0.03797 1829 9146
400 25 11 1 0.11 39.11111 2.84 0.06434 1727 8634
100 400 16 4.8 1 0.11 23.07692 4.81 0.06271 1772 6644
650 40 11 1 0.18 39.11111 4.62 0.10628 1699 6371
150 1000 40 4.3 1 0.28 23.07692 12.04 0.15385 1806 5417
1600 100 9 1 0.44 39.11111 11.36 0.26074 1705 5114
200 1600 65 4.3 10 0.04 230.7692 1.93 0.37661 1180 3540
2500 160 9 10 0.07 391.1111 1.78 0.63829 1088 3264

Body construction
DN ISO PN 20
ISO PN 10 ISO PN 16 ISO PN 25 ISO PN 40
(mm) ANSI 150
50 A A A A A
80 A A A A A
100 B B B - -
150 B B B - -
200 B B B - -
A: EN-GJS-400-18LT Sandwich body (the screws are delivered with the meter)
B: EN-GJS-400-18LT flanges body
Note: for the pressure and temperature range of the body material, please check your National Rules

76 QUANTOMETER MZ
B) Calculation of the extended C) Pressure loss of the MZ meters
rangeability Values: see table above
Calculation of pressure loss:
When the density of the measured gas
increases, the minimum measured flow
rate decreases. This minimum flow rate in
real conditions (QminRC) can be evaluated
using the following formula:
Qmin1.2: minimum flowrate (m3/h) for a
where:
density of 1.2 kg/m3
Δp: Pressure loss in the calculated
rRC: density of the gas in real conditions
conditions
(kg/m3) Δpr: Pressure loss in the reference
conditions
rn: Gas density (kg/m3) at 0° C
and 1013 mbar
Pb: Operating pressure (Bar gauge)
q: Flow rate (m3/h)
Qmax: Maximum flow rate (m3/h)
Tb: Gas temperature (°C).

D) Dimensions (mm) and Weights


ISO PN 10 - ISO PN 40 - ANSI 150
DN L A B C D E Kg
50 60 15 18 156 160 163 4
80 120 35 34 173 180 176 10

ISO PN 10 - ISO PN 16 - ANSI 150


100 150 54 28 209 180 186 19
150 200 71 48 238 225 216 33
200 200 69 43 273 250 277 85

113
A
30
D

B
C E L

QUANTOMETER MZ 77
E) Transmitter characteristics
Intrinsic safety approval: L.C.I.E. 06 ATEX 6031 X
Intrinsic safety level: Ex II 1/2 G Ex ia IIC T5 c T6

Low Frequency pulse transmitters (LF): Inductive transmitters (HF and MF):
The LF transmitter consists of 2 dry Reed They are inductive sensors actuated
switches, normally open, and controlled by a toothed disc. The frequency is
by a magnet situated in the first drum proportional to the instantaneous flow.
of the totaliser. The LF connections are The polarity of the connections is indicated
without polarity. on the name plate of the meter.
1) Internal Reed contacts 1) High Frequency transmitters
ª Hermetically sealed contacts ª Proximity detectors conform to
• Maximum terminal voltage: 30 Volt EN 60947-5-6 (NAMUR) standards.
and maximum current according to ª They conform to CENELEC standards
EN 60079-11. (EN 60079-0 and EN 60079-11) with:
ª Ambient temperature • Ui ≤ 15 Volt
Ta = -30°C to +60°C • Ii ≤ 50 mA
ª Minimum pulse time: 0.4 s • Ci ≤ 90 nF
• Li ≤ 100μH
2) Cyble sensor
• Pi ≤ 120 mW
ª It conforms to CENELEC standard
ª Ambient temperature
EN 60079-11 with:
Ta = -30°C to +60°C
• Ui ≤ 14.3 Volt
• Ii ≤ 50 mA 2) Medium Frequency transmitter
ª It conforms to CENELEC standards
(EN 60079-0 and EN 60079-11) with:
• Ui ≤ 16 Volt
• Ii ≤ 52 mA
• Ci ≤ 50 nF
• Li ≤ 250μH
• Pi ≤ 64 mW
Anti-tampering transmitter (AT):
This consists of one dry Reed switch, normally closed. Attempts at magnetic
tampering will open the contact. The electrical characteristics are the same as those
for the LF transmitter.

F) Installation
Each meter is delivered with binder plugs for the installed transmitters and oil when an
oil pump is installed. Please refer to the instruction manual supplied with the meter.
The advice given therein will ensure optimal use of the MZ quantometer over the years.

78 GA-Quantometer-MZ-EN-V3.0-2012.03
Quantometer
Delta QD KEY BENEFITS
ª High accuracy and
rangeability budget meter
Volumetric Gas Meter
ª Very low pressure loss
ª No influence of installation
Delta QD meters are volumetric meters. The flow conditions nor stop-
of gas moves the pistons and each rotation traps and-go flow rate on the
and transfers a specific volume of gas. accuracy
The movement is mechanically transmitted to the ª Protection class IP67
totaliser. 9-digit mechanical
totaliser
ª Various options available:
APPLICATIONS Cyble Sensor, high
Delta QD are designed to measure natural gas and frequency transmitter,
various filtered and non-corrosive gases as well as thermowell, etc
compressed air.
Due to the volumetric principle of the Delta QD, its
metrology is not influenced by installation conditions.
Consequently, it can be used to build very compact
stations without installing a straight pipe inlet before
the meter.
They have been especially designed
for industrial use and for secondary measurement and
are particularly adapted when the flow can be low or
irregular.

SPECIFICATIONS knowledge to shape your future 79


DESCRIPTION 1 3 4 2

A Delta QD is made up of
four main parts:
➊ A measuring chamber
➋ 2 pistons, which are
synchronised by
2 gears and which rotate
in opposite directions
➌ 1 lubricant cover
➍ A totaliser to register the counted gas
Characteristics
Freq max LF 1 pulse HF Freq max HF Weight A B C D L
Model
(Hz) (dm³/pulse) (Hz) (Kg) (mm) (mm) (mm) (mm) (mm)

QD25 0.69 0.218 31.8 4 126 46 172 126 121

QD65 1.67 0.218 76.4 4 126 46 172 126 121

C L
30 A B

D + 35
D

Compliance with European Directives Design


ª Pressure Equipment Directive 97/23/EC ª Housing: Aluminium hard anodised.
ª ATEX Directive 94/9/EC (Intrinsic safety ª Pistons: Aluminium hard anodised;
level: II 1/2 G Ex ia IIC T5 c T6) dynamically balanced.
ª Ball bearings: stainless steel.
Quantometer
QD60, Qmax:
60m3/h
equipped with
Cyble Sensor
ATEX Installation
Please refer to the instruction manual
supplied with the meter.
The advice given therein will ensure
optimal use of the Delta QD over the
years.

80 GA-Delta-QD-EN-V2.0-2011.12
Rotary Meter
Delta® KEY BENEFITS
ª Excellent metrological stability attested
Commercial & Industrial Meter
by customers over the years
ª No influence of installation conditions nor
Delta meters are volumetric meters. stop-and-go flow rate on the metrology
The flow of gas moves the pistons ª MID approved
and each rotation traps and transfers
ª Optimised pressure loss for low
a specific volume of gas. pressure network
The movement is mechanically ª Available in aluminium, ductile iron, or
transmitted to the totaliser through steel, for all applications
the magnetic coupling. ª Equipped as standard with the Cyble
target

APPLICATIONS
Delta meters are designed to measure by installation conditions. Consequently,
natural gas and various filtered, and non- it can be used to build very compact
corrosive gases. They are used when stations without installing a straight pipe
very accurate measurement is required, inlet before the meter.
when the gas flow can be low or irregular. Delta meters are approved for fiscal use.
Due to the volumetric principle of the
Delta meter, its metrology is not influenced

SPECIFICATIONS knowledge to shape your future 81


DESCRIPTION 1
A Delta meter is made of 5 main parts: 2
4
ª A measuring chamber that is limited by
the body and the 2 base plates (1) 5
ª 2 pistons, which are synchronised by
2 gears and which rotate in opposite 3
directions (2)
ª 2 lubrificant covers (3)
ª A magnetic coupling to transmit the 3

movement of the pistons to the totaliser (4)


ª A totaliser to register the measured gas (5)

Technical Specifications
Flow rate From 0.25 m3/h to 1000 m3/h, G10 to G650
Nominal Diameters DN 25 to DN 150 (1” to 6”)
Maximum Working Up to 100 bar depending on the body material and flanging
Pressure
Body Materials Aluminium, ductile iron or steel.
Compliant with the Pressure Equipment Directive 97/23/EC
Temperature Range ATEX/PED: -30° C to +60° C
MID: -25° C to +55° C
Storage temperature: -40° C to +70° C
Metrology In accordance with the EC and OIML, large rangeability up to 1: 200,
depending on the G-size Approvals EC (PTB): 1.33-3271.3-ROM-E11.
Large rangeability (PTB): 1.33-3271.3-ROM-N05
Compliant with the Measuring Instrument Directive 04/22/EC
Intrinsic Safety L.C.I.E. 06 ATEX 6031 X - Compliant with the Directive 94/9/EC.
Approval

Typical calibration curve


Error in %
3 EC Accuracy
2 Typical Itron Curve
1 High Rangeability
Accuracy
0
-1
-2
-3
0 20 40 60 80 100 % max flow

In accordance with the EC regulation, the maximum permissible error is +/-2%


from Qmin to 0.2 Qmax, and +/-1% from 0.2 Qmax to Qmax. The WME (Weighted
Measured Error) is less than 0.4%.
Typical Itron accuracy is +/-1% from Qmin to 0.2 Qmax, +/-0.5% from 0.2 Qmax to Qmax.

82 ROTARY METER DELTA®


Totaliser:
ª 9-digit index to register a larger volume
ª 45° orientation for an easy reading
ª Free-rotating totaliser Universal
ª Equipped as standard with the cyble totaliser fitted
target: it allows the installation of the as standard
cyble sensor at any time. with the Cyble
target
ª Equipped with 1 built-in silicagel
cartridge; as an option, equipped with
an external cartridge to enable easy
maintenance even in extreme conditions. Transmitters:
ª Fitted with a reflecting disc on the first ª Double Low Frequency fitted as
drum. standard on the whole range.
ª Integrated optical disc to facilitate the ª Anti-tampering is supplied as standard.
periodic calibration of the meter. ª Medium Frequency is supplied as an
ª Customised name plate (logo, option on the DN50 to DN150.
bar-code, customer serial number…). ª High Frequency is supplied as an
ª IP67 protection option on the whole range.
ª UV resistant ª Mechanical drive according to EN
ª Unit: m3 12480 is supplied as an option.

ACCESSORIES / OPTIONS Bracket for mounting a volume converter:


ª 100 μm flat gasket-filter to fit between ª This device permits the Itron Corus
flanges DN40 to DN150. PTZ volume converter to be adapted
directly onto the meter, or at the most
External silicagel cartridge:
convenient place to the meter to enable
ª Accessory for maintenance on the the converter index to be easily read.
installed external silicagel cartridge for
extreme conditions.
Pete´s plug®:
ª Ideal device for filling lubricant in the
cover of the meter while equipment is
in service. It must be fitted instead of
the tap plug of the cover.
Plugged on the pressure tapping, it can Delta DN80 G100
be used to measure the pressure and with Corus PTZ
the temperature of the measured gas.
Connection size: ¼” NPT or ¼” BSP.
Maximum pressure of gas: 20 bar.

Gasket filters Mechanical drive


from DN40 to DN150 according to EN 12480
0

ROTARY METER DELTA® 83


Thermowells:
ª These threaded ¼” NPT thermowells,
can be plugged onto the meter. They can Thermowell fitted with sealing
se aling
li holes
be retrofitted on to the standard version
(plugged onto the existing pressure
tapping), or they can be installed on the
versions equipped with extra-tapping.
The internal diameter of the thermowell
is 7 mm; it enables mounting of most Delta DN50 G65 S1-Flow
standard temperature probes. equipped with extension
for the totaliser and
Extension for the totaliser: by-pass
ª This option allows the possibility to
increase the distance between the body
of the meter and the index, to facilitate
the reading when the meter is covered
with ice due to measurement at low
temperatures.

By-pass:
ª It can be installed as an option on the
steel version DN50. It enables the gas De DN80
Delta
to flow even if the meter is blocked for G100 in
G1
any reason. aluminium
alu
equipped
equ
Cyble sensor: with the Cyble
wit
ª It can be delivered mounted onto the sensor
sen
meter or installed afterwards at any time.
The Cyble sensor is a bounce-free
transmitter. It allows also the counting
of eventual back flows.

DELTA COMPACT - ALUMINIUM ª Only the front cover has to be filled with
lubricant.
Main Characteristics
ª Thermowell: supplied as an option,
ª The Itron Compact DELTA meter is ideal 1 tapping ¼” NPT allows an easy
for installation in extremely small cabinets. installation of a thermowell.
ª Available in thread version (L=121mm) ª Double Low Frequency transmitter
or flanged version (L=171mm). connected on a Binder 6 pins plug.
ª Index can be oriented as required, Anti-tampering is supplied as a standard.
magnetic coupling. ª HF is supplied as an option, connected
ª Multi-position meter, the flow orientation on a Binder 6 pins plug.
does not need to be specified when ª Equipped as standard with the Cyble
ordering the meter. target.

84 ROTARY METER DELTA®


Technical Features
Flow rate 0.25 m3/h to 65 m3/h
G size G10, G16, G25 and G40
Rangeability 1:20 to 1:200
Threaded version DN40 1½’’ BSP or NPT
Flanged version DN25*, DN40 and DN50 (1’’, 1½’’, 2’’) ISO PN10/16, PN20*
and ANSI125-ANSI150
Pressure range Up to 19.3 bar
* with minimum ordering quantity

Threaded version - Aluminium Range DN40:


G Qmax DN Flange Rangea- Starting Flow rate at: Pressure 1 Imp 1 Imp HF Freq
size to flange bility flow Error ≈ -10% loss LF (dm3/Imp) HF at
distance Typical value Δpr(1) (Std. Gears Qmax
3 3 3 3
(m /h) Dim.: L (dm /h) (dm /h) (mbar) (m /Imp) 32/40) (Hz)
G10 16 40 121 20 to 50 25 60 0.3 0.01 0.218 20.4
G16 25 40 121 20 to 100 25 60 0.8 0.01 0.218 31.8
G25 40 40 121 20 to 160 25 60 1.8 0.01 0.218 50.9
G40 65 40 121 20 to 200 25 60 4.8 0.01 0.218 82.8
(1)
Δpr: Pressure loss (mbar) with r = 0.83Kg/m 3 and at Qmax
C
G Vc Weight 30 A B
A B C D
size (dm3) (Kg)
G10 126 46 172 126 0.19 4
G16 126 46 172 126 0.19 4
G25 126 46 172 126 0.19 4
G40 126 46 172 126 0.19 4 D

Delta DN40 G16

L
D + 35

Delta DN40 G16 fitted


d with Cyble sensor

ROTARY METER DELTA® 85


Flanged version - Aluminium Range DN25/DN40/DN50:
G Qmax DN Flange Rangea- Starting Flow rate at: Pressure 1 Imp 1 Imp HF Freq
size to flange bility flow Error ≈ -10% loss LF (dm3/Imp) HF at
distance Typical value Δpr(1) (Std. Gears Qmax
3 3 3 3
(m /h) Dim.: L (dm /h) (dm /h) (mbar) (m /Imp) 32/40) (Hz)
G10 16 25* 171 20 to 50 25 60 0.4 0.01 0.218 20.4
G10 16 40 171 20 to 50 25 60 0.3 0.01 0.218 20.4
G10 16 50 171 20 to 50 25 60 0.3 0.01 0.218 20.4
G16 25 25* 171 20 to 100 25 60 0.8 0.01 0.218 31.8
G16 25 40 171 20 to 100 25 60 0.7 0.01 0.218 31.8
G16 25 50 171 20 to 100 25 60 0.6 0.01 0.218 31.8
G25 40 40 171 20 to 160 25 60 1.8 0.01 0.218 50.9
G25 40 50 171 20 to 160 25 60 1.6 0.01 0.218 50.9
G40 65 40 171 20 to 200 25 60 4.5 0.01 0.218 82.8
G40 65 50 171 20 to 200 25 60 4.2 0.01 0.218 82.8
(1)
Δpr: Pressure loss (mbar) with r = 0.83Kg/m3 and at Qmax * with minimum ordering quantity
C
G Vc Weight 30 A B
A B C D
size (dm3) (Kg)
G10 126 60 186 126 0.19 6
G10 126 60 186 126 0.19 6
G10 126 60 186 126 0.19 6

D
G16 126 60 186 126 0.19 6
G16 126 60 186 126 0.19 6
G16 126 60 186 126 0.19 6
G25 126 60 186 126 0.19 6
L
G25 126 60 186 126 0.19 6
G40 126 60 186 126 0.19 6
G40 126 60 186 126 0.19 6
D + 35

Delta DN50 G40 D


Delta DN50 G40 fitted
with Cyble sensor
w

86 ROTARY METER DELTA®


DELTA 2050/2080/2100 - ALUMINIUM Technical Features
Flow rate 0.4 m3/h to 400 m3/h
Main Characteristics
G size G16, G25, G40, G65,
ª Index can be oriented as required, G100, G160 and G250
magnetic coupling.
Rangeability 1:20 to 1:200
ª Both front and rear covers must be
Nominal diameter 50, 80 and 100
filled with a lubricant.
(2”, 3” and 4”)
ª Multi-position meters, the flow orientation
Flanging PN 10/16, PN20 and
does not need to be specified when
ANSI125-ANSI150
ordering the meter.
Pressure range 16 bar (Option: 19.3 bar)
ª Thermowells: supplied as an option,
2 tappings ¼” NPT allow an easy
installation of thermowells.
ª Double Low Frequency transmitter
connected on a Binder 6 pins plug.
Anti-tampering is supplied as a standard.
ª MF is supplied as an option.
ª HF is supplied as an option, connected
on a 3 pin binder.
ª A G100 DN50 is available to allow the
possibility of increasing the station
capacity; the use of the same flanging
as the G65 DN50 does not require Delta DN100
modification of the existing installation. G250 in aluminium
equipped with HF and Cyble sensor
ª Equipped as standard with the Cyble
target.
C
Aluminium Range DN50/DN80/DN100: 30 A B
G Vc Weight
A B C D
size (dm3) (Kg)
G16 190 121 311 182 0.59 11
G25 190 121 311 182 0.59 11
G40 190 121 311 182 0.59 11
G65 190 121 311 182 0.59 11
G65 228 159 387 182 0.94 15
G100 228 159 387 182 0.94 15
L
G100 228 159 387 182 0.94 15
G160 252 183 435 182 1.16 17
G160 230 179 409 235 1.78 29
G160 265 213 478 235 2.41 34
G250 333 282 615 235 3.65 43
D

ROTARY METER DELTA® 87


Aluminium Range DN50/DN80/DN100:
G Qmax DN Flange Rangea- Starting Flow rate Pressure 1 Imp 1 Imp Freq 1 Imp Freq
size to flange bility flow at: Error loss LF MF MF HF HF
distance ≈ -10% Δpr(1) & at at
3
Dim.: L Typical Cyble Qmax (dm /Imp) Qmax
3 3
value (m / (m / (Std. Gears
(m3/h) (dm3/h) (dm3/h) (mbar) Imp) Imp) (Hz) 32/40) (Hz)
G16 25 50 171 20 to 50 50 150 0.13 0.1 2.72 2.55 0.0585 119
G25 40 50 171 20 to 100 50 150 0.33 0.1 2.72 4.08 0.0585 190
G40 65 50 171 20 to 160 50 150 0.88 0.1 2.72 6.64 0.0585 309
G65 100 50 171 20 to 200 50 150 2.08 0.1 2.72 10.2 0.0585 475
G65 100 80 171 20 to 200 70 250 0.69 0.1 4.36 6.36 0.0939 296
G100 160 50 171 20 to 200 70 250 3.25 0.1 4.36 10.2 0.0939 473
G100 160 80 171 20 to 200 70 250 1.73 0.1 4.36 10.2 0.0939 473
G160 250 80 171 20 to 200 80 250 3.15 0.1 5.28 13.2 0.116 599
G160 250 80 241 20 to 160 150 500 2.73 0.1 8.26 8.41 0.178 390
G160 300 100 241 20 to 160 175 550 2.1 1 21.8 3.82 0.241 346
G250 400 100 241 20 to 160 200 600 2.63 1 32.6 3.40 0.365 304
(1)
Δpr: Pressure loss (mbar) with r = 0.83Kg/m 3 and at Qmax

DELTA 2050/2080/2100 & S3-FLOW - DUCTILE IRON - EN-GJS-400-18LT

Main Characteristics ª High Temperature Loading: fire


ª Index can be oriented as required, resistant PN5 is supplied as an option.
magnetic coupling. ª Equipped as standard with the Cyble
ª Both front and rear covers must be target.
filled with a lubricant.
ª Multi-position meters, the flow orientation
does not need to be specified when
ordering the meter.
ª Thermowells: supplied as an option,
2 tappings ¼” NPT allow an easy
installation of thermowells.
ª Double Low Frequency transmitter
connected on a Binder 6 pins plug.
Anti-tampering is supplied as a standard.
ª MF is supplied as an option.
ª HF is supplied as an option (up to 3 HF Delta DN80 G100 3xDN
possible for the S3-Flow!). in Ductile iron equipped with Cyble sensor

88 ROTARY METER DELTA®


Technical Features
Flow rate 0.4 m3/h to 1000 m3/h
G size G16, G25, G40, G65, G100, G160, G250, G400 and G650
Rangeability 1:20 to 1:200
Nominal diameter 50, 80, 100 and 150 (2”, 3”, 4” and 6”)
Flanging PN 10/16, PN20 and ANSI150
Pressure range 16 bar (Option: 19.3 bar)

Ductile iron Range DN50/80/100/150: C


G Vc Weight 30 A B
A B C D
size (dm3) (Kg)
G16 228 150 378 174 0.94 25
G16 190 112 302 174 0.59 19
G25 228 150 378 174 0.94 25
G25 190 112 302 174 0.59 19
G40 228 150 378 174 0.94 25
G40 190 112 302 174 0.59 19
G65 228 150 378 174 0.94 25
G65 190 112 302 174 0.59 19
G65 228 150 378 194 0.94 25 L

G65 252 174 426 225 1.16 30


G65 228 150 378 194 0.94 27
G100 228 150 378 194 0.94 25
G100 228 150 378 194 0.94 25
G100 252 174 426 225 1.16 30
D

G100 228 150 378 194 0.94 27


G100 230 179 409 235 1.78 45
G100 252 174 426 225 1.16 30
G160 252 174 426 225 1.16 30
G160 230 179 409 235 1.78 41
G160 230 179 409 235 1.78 45
G160 252 174 426 225 1.16 30
G160 252 174 426 225 1.16 30
G250 333 282 615 235 3.65 56
G250 333 282 615 235 3.65 61
G250 343 267 610 365 5.4 120
G400 343 267 610 365 5.4 120
G650 343 267 610 365 5.4 120

ROTARY METER DELTA® 89


Ductile iron Range DN50/80/100/150:
G Qmax DN Flange Rangea- Starting Flow rate Pressure 1 Imp 1 Imp Freq 1 Imp Freq
size to flange bility flow at: Error loss LF MF MF HF HF
distance ≈ -10% Δpr(1) & at at
3
Dim.: L Typical Cyble Qmax (dm /Imp) Qmax
3 3
value (m / (m / (Std. Gears
(m3/h) (dm3/h) (dm3/h) (mbar) Imp) Imp) (Hz) 32/40) (Hz)
G16 25 50 150 20 to 50 70 250 0.1 0.1 4.36 1.59 0.0939 74
G16 25 50 171 20 to 50 50 150 0.13 0.1 2.72 2.55 0.0585 119
G25 40 50 150 20 to 100 70 250 0.21 0.1 4.36 2.55 0.0939 118
G25 40 50 171 20 to 100 50 150 0.33 0.1 2.72 4.08 0.0585 190
G40 65 50 150 20 to 160 70 250 0.55 0.1 4.36 4.14 0.0939 192
G40 65 50 171 20 to 160 50 150 0.88 0.1 2.72 6.64 0.0585 309
G65 100 50 150 20 to 200 70 250 1.3 0.1 4.36 6.36 0.0939 296
G65 100 50 171 20 to 200 50 150 2.08 0.1 2.72 10.2 0.0585 475
G65 100 80 171 20 to 200 70 250 0.69 0.1 4.36 6.36 0.0939 296
G65 100 80 230 20 to 80 80 250 0.52 0.1 5.28 5.26 0.116 239
G65 100 80 240 20 to 200 70 250 0.69 0.1 4.36 6.36 0.0939 296
G100 160 50 150 20 to 200 70 250 3.25 0.1 4.36 10.2 0.0939 473
G100 160 80 171 20 to 200 70 250 1.73 0.1 4.36 10.2 0.0939 473
G100 160 80 230 20 to 130 80 250 1.32 0.1 5.28 8.42 0.116 383
G100 160 80 240 20 to 200 70 250 1.73 0.1 4.36 10.2 0.0939 473
G100 160 80 310 20 to 100 150 500 1.15 0.1 8.26 5.38 0.178 250
G100 160 100 241 20 to 130 80 250 0.9 0.1 5.28 8.42 0.116 383
G160 250 80 230 20 to 200 80 250 3.15 0.1 5.28 13.2 0.116 599
G160 250 80 241 20 to 160 150 500 2.73 0.1 8.26 8.41 0.178 390
G160 250 80 310 20 to 160 150 500 2.73 0.1 8.26 8.41 0.178 390
G160 250 100 230 20 to 200 80 250 2.2 0.1 5.28 13.2 0.116 599
G160 250 100 241 20 to 200 80 250 2.2 0.1 5.28 13.2 0.116 599
G250 400 100 241 20 to 160 200 600 2.63 1 32.6 3.40 0.365 304
G250 400 100 400 20 to 160 200 600 2.63 1 32.6 3.40 0.365 304
G250 400 150(2) 450 20 to 100 400 1000 0.77 1 48.0 2.31 0.595 187
G400 650 150(2) 450 20 to 160 400 1000 2.03 1 48.0 3.76 0.595 303
G650 1000 150(2) 450 20 to 200 400 1000 4.8 1 48.0 5.79 0.595 467
(1)
Δpr: Pressure loss (mbar) with r = 0.83Kg/m 3 and at Qmax
(2)
S3-Flow meter

90 ROTARY METER DELTA®


DELTA S1-FLOW & 2080 - STEEL

Main Characteristics
ª Index can be oriented as required, magnetic coupling.
ª Double Low Frequency transmitter connected on a 6 pin Binder plug. Anti-tampering
is supplied as a standard.

DN50
ª G16 to G100
ª S-Flow technology
ª Only the front cover must be filled with
a lubricant.
ª Multi-position meter
ª MF is supplied as an option.
ª 2 thermowells are supplied as option.
ª A by-pass can be installed as an option.
It enables the gas to flow even if the
meter is blocked for any reason.
ª An alarm can be remotely sent
requesting for maintenance.
ª Up to 2 HF are supplied as option.

DN80 Delta DN50 G65 S1 Flow in steel and


ª G100 to G160 equipped with by-pass
ª Conventional principle
ª Both front and rear covers must be
filled with a lubricant.
ª Horizontal inlet left-vertical inlet top or
horizontal inlet right-vertical inlet
bottom (to be specified when ordering).
ª 1 HF is supplied as an option.

Technical Features
Flow rate 0.4 m3/h to 250 m3/h
G size G16, G25, G40, G65, G100 and G160
Rangeability 1:20 to 1:200
Nominal diameter 50 and 80 (2” and 3”)
Flanging PN 10/16 to PN110, ANSI 150 to ANSI600
Pressure range 101.2 bar

ROTARY METER DELTA® 91


Steel Range DN50/80:
G Qmax DN Flange Rangea- Starting Flow rate Pressure 1 Imp 1 Imp Freq 1 Imp Freq
size to flange bility flow at: Error loss LF MF MF HF HF
distance ≈ -10% Δpr(1) & at at
3
Dim.: L Typical Cyble Qmax (dm /Imp) Qmax
3 3
value (m / (m / (Std. Gears
(m3/h) (dm3/h) (dm3/h) (mbar) Imp) Imp) (Hz) 32/40) (Hz)
G16 25 50(2) 240 20 to 30 50 150 0.09 0.1 2.31 3.01 0.0496 140
G25 40 50(2) 240 20 to 65 50 150 0.23 0.1 2.31 4.81 0.0496 224
G40 65 50(2) 240 20 to 100 50 150 0.6 0.1 2.31 7.82 0.0496 364
G65 100 50(2) 240 20 to 160 50 150 1.42 0.1 2.31 12.0 0.0496 560
G100 160 50(2) 240 20 to 200 50 150 3.64 0.1 2.31 19.3 0.0496 896
G100 160 80 320 20 to 30 150 500 1.15 0.1 8.26 5.38 0.178 250
G160 250 80 320 20 to 50 150 500 2.73 0.1 8.26 8.41 0.178 390
Δpr: Pressure loss (mbar) with r = 0.83Kg/m 3 and at Qmax
(1)

(2)
S3-Flow meter
C
30 A B 40
G Vc Weight
A B C D
size (dm3) (Kg)
G16 190 100 290 150 0.49 34
G25 190 100 290 150 0.49 34
G40 190 100 290 150 0.49 34
G65 190 100 290 150 0.49 34
G100 190 100 290 150 0.49 34
G100 231 185 416 275 1.78 84
G160 231 185 416 275 1.78 84

L
190
D

92 ROTARY METER DELTA®


A) TRANSMITTER CHARACTERISTICS
Intrinsic safety approval: L.C.I.E. 06 ATEX 6031 X
Intrinsic safety level: Ex II 1/2 G Ex ia IIC T5 c T6

Low Frequency pulse transmitters (LF): Inductive transmitters (HF and MF):
The LF transmitter consists of 2 dry Reed They are inductive sensors actuated
switches, normally open, and controlled by a toothed disc. The frequency is
by a magnet situated in the first drum proportional to the instantaneous
of the totaliser. The LF connections are flow. The polarity of the connections is
without polarity. indicated on the name plate of the meter.

1) Internal Reed contacts 1) High Frequency transmitters


ª Hermetically sealed contacts ª Proximity detectors conform to
• Maximum terminal voltage: 30 Volt EN 60947-5-6 (NAMUR) standards.
and maximum current according to ª They conform to CENELEC standards
EN 60079-11. (EN 60079-0 and EN 60079-11) with:
ª Ambient temperature • Ui ≤ 15 Volt
Ta = -30°C to +60°C • Ii ≤ 50 mA
ª Minimum pulse time: 0.4 s • Ci ≤ 90 nF
• Li ≤ 100 μH
2) Cyble sensor
• Pi ≤ 120 mW
ª It conforms to CENELEC standard
ª Ambient temperature
EN 60079-11 with:
Ta = -30°C to +60°C
• Ui ≤ 14.3 Volt
• Ii ≤ 50 mA 2) Medium Frequency transmitter
ª It conforms to CENELEC standards
(EN 60079-0 and EN 60079-11) with:
• Ui ≤ 16 Volt
• Ii ≤ 52 mA
• Ci ≤ 50 nF
• Li ≤ 250 μH
• Pi ≤ 64 mW

Anti-tampering transmitter (AT):


This consists of one dry Reed switch,
normally closed. Attempts at magnetic
tampering will open the contact. The
electrical characteristics are the same as
Delta DN150 G650 S3-Flow in Ductile iron those for the LF transmitter.

ROTARY METER DELTA® 93


B) PRESSURE LOSS C) INSTALLATION
OF THE DELTA METERS Each meter is delivered with binder
Calculation of pressure loss: plugs for the installed transmitters and
oil for the lubrication. Please refer to
the instruction manual supplied with
the meter.
The advice given therein will ensure
where: optimal use of the Delta meter over
Δp: Pressure loss in the calculated the years.
conditions
Δpr: Pressure loss in the reference
conditions
rn: Gas density (kg/m3) at 0° C
and 1013 mbar
Pb: Operating pressure (Bar gauge)
q: Flow rate (m3/h)
Qmax: Maximum flow rate (m3/h)
Tb: Gas temperature (°C).

94 GA-Delta-EN-V4.0-2011.12
FM3

DATTUS™
KEY BENEFITS
ª Static Measurement Technology
ª Available in Basic, Temperature
Residential Diaphragm Gas Meter Compensated (ETC) or Pressure and
Temperature Compensated (PTZL)
OPERATING PRINCIPLE versions
he operation of the Dattus meter is based ª Data Logging
on the fluidic oscillation principle. ª Configurable Pulse Outputs
The measurement unit is comprised of ª Capacities up to 56,000 CFH (1585 M3/h)
three functional elements: ª Field Upgrading of Meter Capacity
• Flow conditioner without Service Interruption
• Jet nozzle formation ª Programmable Fixed Factor Compensation
• Fluidic oscillator chamber ª Configurable Index Orientation
ª Gas enters (1) the meter and divides
into two separate flow paths (2). These 4. Nozzle Forms Jet
two flows recombine (3) as they exit the 2. Flow 5. Obstacle
flow conditioner and enter the fluidic Divided Oscillation
oscillation chamber through the nozzle.
This process of dividing the flows
eliminates upstream disturbances and
1. Entry 6. Exit
creates a well-conditioned flow.
ª In the fluidic oscillation chamber, a jet
is formed (4) as the gas enters through
the nozzle. 3. Recombined Turbulance Induced
The jet then starts oscillating back and
forth (5). 5
ª Thermal sensors, located just after the 4
nozzle, detect a temperature variance 1 3
as the gas jet passes from one side to 6
2
the other. The volume of gas passed
through the meter is obtained by 2
counting the number of oscillations Side Cutaway-view Internal View of Meter
detected by the sensors. Operating Principle of the Measurement Unit

SPECIFICATIONS knowledge to shape your future 95


METER CONFIGURATION STANDARD CONFIGURATION
ª Basic - Uncorrected measurement ª Gas Volume Totaling
ª Basic EXT - Basic Extended, ª Fixed Factor Correction
Uncorrected measurement with ª 4 channels of pulse outputs
additional display allowing access to ª Event Logging
metering information without using
ª MODBUS protocol
software
ª RS232 port
ª ETC: Includes Electronic Temperature
Compensation OPTIONAL FEATURES
ª P-only: Includes compensation for ª Data Logging (standard with PTZL
variable pressure version)
ª PTZL: Includes compensation for ª Temperature Compensation
temperature, pressure, and super
ª Pressure Compensation
compressibility
ª Capacity upgrades

SPECIFICATIONS
Technical features Pulse Output
Imperial Metric Pulse type Open drain N channel
MAOP MOSFET, non-isolated,
dry contact, 240 ohm
FM2 150 psig 10.3 bar contact resistance
FM3 175 psig 12 bar Pulse duration User configurable
Flange to Flange between 10ms and
1.75 seconds or 50%
FM2 6.75 in 171.5 mm
duty cycle
FM3 9.5 in 241 mm
Pulse value User configurable
Minimum Flow Rate
Temperature Probe
FM2 22 acfh 0.62 m3/h
Type PT1000, platinum
FM3 60 acfh 1.7 m3/h resistance thermistor
Available meter capacity sizes (RTD)
FM2 1M, 1.5M, 2M, 3M, 5M, 7M, and 11M Typical accuracy 0.1% of absolute
FM3 7M, 11M, 16M, 23M, 38M, and 56M measurement

Meter Weight Pressure Transducers


FM2 37 lbs 16.8 kg Available in Gauge or Absolute
FM3 114 lbs 51.7 kg Ranges of 0-60 PSI (0-4 Bar),
0-100 PSI (0-7 Bar), and 0-150 PSI (0-10 Bar)
Typical accuracy: 0.3% of scale
Construction
Measurement Unit Cast aluminium A356T6
External Cover ASA (Acrylonitrile
Styrene Acrylate)
Index Housing UV stabilized
Dattus FM2 polycarbonate

96 This brochure is currently being updated, for full details on the Dattus range see www.itron.com
Fluxi
2000/TZ
BASIC FEATURES
ª PTB approved with only 2 DN inlet
straight pipe, 0 (zero) DN outlet pipe
Turbine Gas Meter even with severe perturbations
ª MID approved
Turbine gas meters are flow meters. ª Go beyond compliance with all current
The flow of gas turns a turbine European and International Standards
wheel, and thus, the rotating speed ª Reduced pressure loss for low
pressure network
of the turbine is proportional to the
ª Excellent high-pressure behaviour
linear speed of the gas.
ª IP 67 protection of the totaliser
The movement is mechanically
transmitted to the totaliser through ª Equipped as standard with the cyble
target.
the magnetic coupling.
ª Various options available: integrated
thermowells, oil pump, pulse
DESCRIPTION transmitters, etc

The Fluxi 2000/TZ meter is composed


5
of five main parts: 1
➊ a body containing all the components;
➋ a flow straightener to stabilise and
accelerate the gas flow before the
turbine wheel; 4
➌ a measuring unit including the turbine
wheel;
➍ a magnetic coupling to transmit the
movement of the turbine wheel to the
totaliser;
➎ a totaliser to register the measured gas. 2 3

SPECIFICATIONS knowledge to shape your future 97


APPLICATIONS The Fluxi 2000/TZ meters have been
Fluxi 2000/TZ meters are designed to optimised for use in all applications
measure natural gas, and various filtered, related to the transportation and
and non-corrosive gases. They are used distribution of gas. Fluxi 2000/TZ meters
to measure medium to high gas flow, at are approved for fiscal use.
low, medium or high pressure.

Technical Specifications
Metrological Approvals Compliant with the Measuring Instrument Directive 2004/22/EC
Approval number: DE-10-MI002-PTB001
Intrinsic Safety Approval Compliant with the Directive 94/9/EC
Approval number: LCIE 06 ATEX 6031 X
Flow Rate From 5 m3/h to 10000 m3/h, G65 to G6500.
Nominal Diameters From DN50 to DN500 mm (2” to 20”).
Maximum Working Up to 100 bar depending on the body material and flanging.
Pressure
Mounting The Fluxi 2000/TZ meters can be installed either horizontally or
vertically, for the DN50 to DN300, and horizontally for the DN400
and DN500.
Body Materials Ductile iron, cast steel or welded steel.
Compliant with the Pressure Equipment Directive 97/23/EC
Approval number: DVGW CE-0085BM 0417
Temperature Range ATEX/PED: -30°C to +60°C
MID: -25°C to +55°C
Storage temperature: -40°C to +70°C

METROLOGY In line with EC regulation, the maximum


In accordance with the EC regulation permissible error is +/-2 %, from Qmin to
and OIML. 0.2 Qmax, and +/-1% from 0.2 Qmax to
Qmax. The WME (Weighted Measured
Depending on the G size and the DN, the
Error) is less than 0.4%.
meters are available with a rangeability of
1:20 or 1:30. According to the PTB TR G7, Typical Itron accuracy is: +/-1% from
for high-pressure tests, the rangeability Qmin to 0.2 Qmax, +/-0.5% from
can be extended to 1:50, depending on 0.2 Qmax to Qmax.
the pressure.
Error in %
3
Low Pressure Curve
2 High Pressure Curve
Typical Itron Accuracy
1 EC Accuracy
0

-1

-2

-3
0 20 40 60 80 100% max flow

98 FLUXI 2000/TZ
Totaliser: ª Integrated optical disc to facilitate the
ª 9-digit index to register a larger volume periodic calibration of the meter.
ª 45° orientation for an easy reading ª Customised name plate (logo,
bar-code, customer serial number...)
ª Free-rotating totaliser
ª IP67 protection
on
ª Equipped as standard with the cyble
target: it allows the installation of the ª UV resistant
cyble sensor at any time. ª Unit: m3
ª Equipped with 1 built-in silicagel
cartridge; as an option, equipped with
Universal
an external cartridge to enable easy
totaliser fitted
maintenance even in extreme conditions as standard
ª Fitted with a reflecting disc on the first with the
drum. Cyble target

Transmitters
➊ Cyble sensor: It can be delivered ➍ High Frequency (HF): up to 4
mounted onto the meter or installed transmitters are supplied as an option
afterwards at any time. The Cyble on the whole range:
sensor is a bounce-free transmitter. 2 fitted close to the turbine wheel
It allows also the counting of eventual (HF3), and 1* close to a reference
back flows. wheel (HF2).
➋ Low Frequency (LF): Two Reed *DN200 to DN500 ISO PN50/PN110, ANSI300/600
switches are fitted as standard on the are also available as option with 2 HF2 and 2 HF3.
whole range. Anti-tampering (AT): this ➎ Mechanical drive: the totaliser can be
device is fitted as standard on the fitted with this option, it may be used
whole range. to drive removable accessories. The
➌ Medium Frequency (MF): one mechanical drive is designed
transmitter is supplied as an option. according to EN 12261.

1 2 LF1 3 4

MAGNET LF2 AT

Oil pump
➏ An oil pump is supplied as an option,
which lubricates the main ball
bearings in the measuring unit. The
oiling can be done even when the
meter is under pressure.
5 6

FLUXI 2000/TZ 99
Turbine wheel OPTIONS:
➐ This is the most important component Extension for the totaliser
of the meter for achieving high accuracy ➒ This option allows the possibility of
at low and high pressure. It can be made increasing the distance between the
from aluminium for the whole range or in body of the meter and the index, to
polyacetal for the DN≤200. facilitate the reading when the meter is
Depending of the G size, the blades of covered with ice due to measurement of
the turbine wheel are oriented at 45° or gas at low temperatures.
60°. Turbine wheel at 60° is used to avoid
over-speed of the wheel.
9
When a HF3 is requested, the wheel
must be in aluminium. 7
For high pressure use,
or for measuring dirty
gases, an aluminium
wheel is recommended.
Flow Straightener
➑ This device stabilises and accelerates Pressure
ssure tapping:
the flow before the turbine wheel. It has This device allows the gas pressure to
been designed to meet the requirements be measured at the reference point. It
of the 2 perturbation tests defined in the is installed as standard. The standard
EN12261 (low level and high level pressure tapping is an Ermeto 6S.
perturbation).
All DN meet the requirements of the low Measurement of aggressive gases:
level perturbation test without an A version with a PTFE (Teflon) coating is
additional device with only 2 DN inlet available, as an option up to DN200.
straight pipe, 0 DN outlet of the meter.
From DN50 to DN150, no additional ACCESSORIES
device is required to fulfil the high level Bracket for mounting a volume
perturbation test with only 2 DN inlet, 0 converter
DN outlet of the meter.
This device allows the Itron PTZ volume
From DN200 to DN400, a flow conditioner converter to be adapted directly onto
has to be integrated in the inlet of the flow the meter.
straightener to meet the requirements of
the high level perturbation test when only Thermowells
ailable
2 DN inlet pipe is available This device allows the temperature of the
s).
(see in § Accessories). measured gas to be read at the reference
The large number of 8
point, downstream of the turbine.
blades fitted in the The meter is prepared as standard for the
flow straightener installation of two thermowells which can
insures an optimal be mounted in our factory or later when
protection in case requested.
of perturbated flow. The meter does not need to be
recalibrated after retrofitting of thermowell
(as defined in the PTB type Approval).

100 FLUXI 2000/TZ


Flow conditioner CHARACTERISTICS
For DN50 to DN200, a flow A) Technical data sheet
conditioner can be supplied for
Rangeability and pulse values
installation between 2 RF flanges in
front of the meter, to further enhance G DN Max Rangeability 1 Imp Freq
the performance of the meter when size Flow LF & LF
Cyble Qmax
subjected to severe perturbation. 3 3
(mm) (m /h) (m /Imp) (Hz)
For DN200 to DN400, the flow
G65 50 100 20 0.1 0.28
conditioner can be retrofitted directly
in the inlet of the flow straightener. G100 80 160 20 1 0.04
The integration of the flow conditioner G160 250 20 or 30 0.07
in the meter provides a very compact G250 400 20 or 30 0.11
solution without need for any extra
G160 100 250 20 1 0.07
flanging.
G250 400 20 or 30 0.11
External silicagel cartridge G400 650 20 or 30 0.18
This accessory is used to reinforce G400 150 650 20 1 0.18
the protection of the totaliser against
G650 1000 20 or 30 0.28
humidity when the meter is installed
in extrem conditions. G1000 1600 20 or 30 0.44
G650 200 1000 20 10 0.03
G1000 1600 20 or 30 0.04
G1600 2500 20 or 30 0.07
G1000 250 1600 20 10 0.04
G1600 2500 20 or 30 0.07
G2500 4000 20 or 30 0.11
G1600 300 2500 20 10 0.07
G2500 4000 20 or 30 0.11
G4000 6500 20 or 30 0.18
G2500 400 4000 20 10 0.11
G4000 6500 20 or 30 0.18
G6500 10000 20 or 30 0.28
G4000 500 6500 20 or 30 10 0.18
G6500 10000 20 or 30 0.28

Fluxi 2000/TZ with PTZ CORUS

FLUXI 2000/TZ 101


Rangeability and
pulse values (cont’d) With correction gears 32/40 (correction 0%)

G size DN 1 Imp Freq 1 Imp Freq 1 Imp Freq RPM


MF MF HF2 HF2 HF3 HF3 Qmax
Qmax Qmax Qmax (Rot/
(mm) (dm3/Imp) (Hz) (dm3/Imp) (Hz) (dm3/Imp) (Hz) min)

G65 50 5.8947 4.71 - - 0.00970 2864 14322

G100 80 23.07692 1.93 0.07593 585 0.03797 1171 5853


G160 23.07692 3.01 0.07593 915 0.03797 1829 9146
G250 39.11111 2.84 0.12869 863 0.06434 1727 8634
G160 100 23.07692 3.01 0.06271 1107 0.06271 1107 4153
G250 23.07692 4.81 0.06271 1772 0.06271 1772 6644
G400 39.11111 4.62 0.10628 1699 0.10628 1699 6371
G400 150 23.07692 7.82 0.15385 1174 0.15385 1174 3521
G650 23.07692 12.04 0.15385 1806 0.15385 1806 5417
G1000 39.11111 11.36 0.26074 1705 0.26074 1705 5114
G650 200 230.7692 1.2 0.37661 738 0.37661 738 2213
G1000 230.7692 1.93 0.37661 1180 0.37661 1180 3540
G1600 391.1111 1.78 0.63829 1088 0.63829 1088 3264
G1000 250 230.7692 1.93 0.5787 768 0.5787 768 1920
G1600 230.7692 3.01 0.5787 1200 0.5787 1200 3000
G2500 391.1111 2.84 0.9808 1133 0.9808 1133 2832
G1600 300 218.1818 3.18 0.85763 810 0.85763 810 1735
G2500 218.1818 5.09 0.85763 1296 0.85763 1296 2776
G4000 391.1111 4.62 1.53739 1174 1.53739 1174 2517
G2500 400 218.1818 5.09 2.04673 543 2.04673 543 1163
G4000 218.1818 8.28 2.04673 882 2.04673 882 1890
G6500 391.1111 7.1 3.66896 757 3.66896 757 1622
G4000 500 218.1818 8.28 2.04673 882 2.04673 882 1890
G6500 391.1111 7.1 3.66896 757 3.66896 757 1622

102 FLUXI 2000/TZ


Body materials and approximate weight (Kg)
DN Length ISO ISO ISO ISO ISO ISO ISO ANSI ANSI ANSI
of body PN PN PN PN PN PN PN 150 300 600
(mm) (mm) 10 16 20 25 40 50 110
50 150 A(1) A(1) A(1) B(1) A(1) A(1) B(2) B(2) A(1) B(1) B(2) B(2)
8 8 8 8 8 11 11 8 11 11
80 240 Ac Ac AB Ac Ac B B AB B B
19 19 19 19 19 30 37 19 30 37
100 300 Ac Ac AB B B B B AB B B
22 22 22 25 25 45 55 22 45 55
150 335 A(3) A(3) A(3) - - - - A(3) - -
46 46 46 46
150 450 AB AB AB B B B B AB B B
54 54 54 54 54 80 95 54 80 95
200 600 Ac Ac AB B B B(4) B(4) AB B(4) B(4)
83 83 83 83 110 130 150 83 130 150
250 750 B B B B B B(4) B(4) B B(4) B(4)
120 120 120 120 140 220 245 120 220 245
300 900 B B B B B B(4) B(4) B B(4) B(4)
190 190 190 190 220 265 265 190 265 295
400 1200 B B B B B B(4) B(4) B B(4) B(4)
440 440 440 440 490 680 740 440 680 740
500 1500 B B B B B B(4) B(4) B B(4) B(4)
580 580 580 580 640 770 950 580 770 950
(1)
A: Ductile iron EN-GJS-400-18LT HF2 not available, 1 thermowell only
(2)
B: Steel (Cast steel GS or welded steel) HF2 not available
c: Cast steel GS with minimum ordering quantity (3)
HF2 and thermowells not available
(4)
2 HF2 & 2 HF3 available
Note: for the pressure and temperature range of the body material, please check your National Rules

FLUXI 2000/TZ 103


B) Pressure loss Pressure losses
of the Fluxi 2000/TZ meters of the Fluxi 2000/TZ meter (mbar)
With integrated
G DN Standard
Max. Flow (m3/h) flow conditioner
size (mm) ΔPr
ΔPr
r = 0.83kg/m3. r =0.83kg/m3.
T = 0°C. Qmax T=0°C. Qmax
G65 50 100 9.1 -
G100 80 160 2.4 -
G160 250 5.9
G250 400 12.8
G160 100 250 2.2 -
G250 400 5.4
G400 650 11.8
G400 150 650 2.7 -
G650 1000 6.6
G1000 1600 13.8
G650 200 1000 1.6 2.6
G1000 1600 4.0 6.3
G1600 2500 8.7 13.7
G1000 250 1600 2.1 3.3
G1600 2500 5.0 8.0
G2500 4000 11.0 17.3
G1600 300 2500 2.0 3.2
G2500 4000 5.0 7.8
G4000 6500 9.5 17.0
G2500 400 4000 1.8 2.8
G4000 6500 4.4 6.8
G6500 10000 9.5 14.9
G4000 500 6500 4.4 6.8
G6500 10000 9.5 14.9

Calculation of pressure loss:


where:
Δp: Pressure loss in the calculated
conditions
Δpr: Pressure loss in the reference
conditions
rn: Gas density (kg/m3) at 0° C
and 1013 mbar
Pb: Operating pressure (Bar gauge)
q: Flow rate (m3/h)
Qmax: Maximum flow rate (m3/h)
Tb: Gas temperature (°C).

104 FLUXI 2000/TZ


C) Dimensions (mm)
DN L L short* A A short* B B short* C D E
50 150 - 60 - 45 - 125 150 175
80 240 - 96 - 60 - 150 170 180
100 300 - 124 - 82 - 175 180 195
150 450 335 185 92 122 101 205 215 205
200 600 - 240 - 175 - 230 245 240
250 750 - 275 - 273 - 300 275 270
300 900 - 360 - 300 - 300 300 300
400 1200 - 450 - 540 - 350 355 350
500 1500 - 470 - 820 - 390 385 383
* Short version, same length as for the former NM meter
113
A

30
E

B
C D L

D) Thermowells sizes
Order Number d d Max. Setting
L X
DN Thread with stuffing bore Cable Depth (S)
(mm) (mm)
box & o-ring (mm) (mm) Sensor (mm)

50(LP)/80/100 G¼A E952-014-04 7.5 4-8 60 59 12

50(HP)/150/200 G¼A E952-014-14 7.5 4-8 90 93 12


250/500 G½A E952-014-05 8 4-8 150 147 14

L
X
d

S
Thermowell fitted with sealing holes

FLUXI 2000/TZ 105


E) Transmitter characteristics
Intrinsic safety approval: L.C.I.E. 06 ATEX 6031 X
Intrinsic safety level: Ex II 1/2 G Ex ia IIC T5 c T6

Low Frequency pulse transmitters (LF): Inductive transmitters (HF and MF):
The LF transmitter consists of 2 dry Reed They are inductive sensors actuated
switches, normally open, and controlled by a toothed disc. The frequency is
by a magnet situated in the first drum proportional to the instantaneous flow.
of the totaliser. The LF connections are The polarity of the connections is indicated
without polarity. on the name plate of the meter.
1) Internal Reed contacts 1) High Frequency transmitters
ª Hermetically sealed contacts ª Proximity detectors conform to
• Maximum terminal voltage: 30 Volt EN 60947-5-6 (NAMUR) standards.
and maximum current according to ª They conform to CENELEC standards
EN 60079-11. (EN 60079-0 and EN 60079-11) with:
ª Ambient temperature • Ui ≤ 15 Volt
Ta = -30°C to +60°C • Ii ≤ 50 mA
ª Minimum pulse time: 0.4 s • Ci ≤ 90 nF
2) Cyble sensor • Li ≤ 100μH
ª It conforms to CENELEC standard • Pi ≤ 120 mW
EN 60079-11 with: ª Ambient temperature
• Ui ≤ 14.3 Volt Ta = -30°C to +60°C
• Ii ≤ 50 mA 2) Medium Frequency transmitter
ª It conforms to CENELEC standards
(EN 60079-0 and EN 60079-11) with:
• Ui ≤ 16 Volt
• Ii ≤ 52 mA
• Ci ≤ 50 nF
• Li ≤ 250μH
• Pi ≤ 64 mW
Anti-tampering transmitter (AT):
This consists of one dry Reed switch, normally closed. Attempts at magnetic
tampering will open the contact. The electrical characteristics are the same as those
for the LF transmitter.

F) Installation
Each meter is delivered with binder plugs for the installed transmitters and oil when an
oil pump is installed. Please refer to the instruction manual supplied with the meter.
The advice given therein will ensure optimal use of the Fluxi 2000/TZ meter over the years.

106 GA-Fluxi-2000-TZ-EN-V3.0-2012.01
Meters & Smart Smart
Modules Residential Commercial
Metering + Industrial
Metering
Meters “e” series* “e” series* 109
“c” series* “c” series* 113
“o” series 121
Diaphragm Metering ACD G10-G16 131
G25-G40 131
G65-G100 131
Communication Modules Cyble Sensor ATEX 133
Volume Converter Corus 137
Corus Compact 145
Modem FOCUS + 151
Software Saturne* Saturne* 127
Accessories ISB + 157
*Available for Smart Residential and Smart Commercial & Industrial Metering.

107
w w w. i t r o n . c o m

108
“e” series
Smart Meters - Gas Meters with Electronic Index

CO2 and climate change impacts today’s KEY BENEFITS


and future businesses all across the ª 2-way wired/wireless M-Bus
world. Regulatory frameworks, incentives communication
and an ever-growing demand for ª Optional internal shut-off valve and
resources favor investments into energy temperature correction
efficiency solutions. ª Safe data transmission with AES
ª MID approved

Water Gas Heat Electricity Data Collection Utility Mainframe


Software (Billing System / Customer
Information System)

1 2

SPECIFICATIONS knowledge to shape your future 109


Building Blocks of Itron’s ECO series
The “e” series is part of Itron’s complete “eco” portfolio which address today’s and
future energy resource and environmental challenges.

Electronic Compliance with Energy Rules &


RF1, M-Bus: Standards
index,
ACD, optical
Wired,
Wireless Supporting the well established European
G25 pulse M-Bus standard, the “e” series is designed
Base Meter Index Communication to facilitate integration into wired and
Module wireless fixed networks, minimizing
Key Advantages of “e” series installation costs. Infrastructure
ª High accuracy error curve correction investments are well safeguarded in the
fast moving market environment with
ª Optional temperature conversion
M-Bus as communication protocol and
ª Built-in 2-way wired/wireless M-Bus MID approval.
communication
A LC display, time stamped indexes
ª Optional internal shut-off valve and data logging functionality provide an
ª Safe data transmission with AES interface to inform customers about their
ª Tamper protection and detection consumption to fulfill all legal requirements.

ADVANCED METER INFRASTRUCTURE


In this context, Advanced Metering With a long track record in the provision
Infrastructure provides the foundation of highest quality and most accurate
enabling a more sensible stewardship measurement systems, Itron is a trusted
with our natural resources and empowers partner providing a complete system from
utilities to take advantage of the related the meter to the data collection system
opportunities. Instant meter reading (Saturne) to the data management system
through two way communication allows (Itron Enterprise Edition - IEE),
utilities to reduce read to cash time, thus turning data into
prevent billing errors, improve customer knowledge.
service and offer completely new value
adding services. Saturne

GPRS Itron
Enterprise
ACE 4000 GPRS Edition
(IEE)

110 “E” SERIES


OPERATION MULTI-ENERGY SOLUTION
The “e” series gas meter sends data to As part of Itron’s multi-energy solution
a M-Bus master working as a data portfolio, the “e” series is well matched to
concentrator such as the Itron ACE 4000 all necessary components in the value
GPRS electricity meter. chain, such as the ACE 4000 GPRS
The concentrator forwards the data to a electricity meter or the meter data
central software system, where it can be management system (IEE).
used for billing, energy data management, As an end to end solution provider, Itron’s
or other applications. turnkey solutions minimize your investment
risks.
SATURNE: PLC/GPRS
Fixed Data Collection System ROBUSTNESS & SAFETY
ª Multi-energy solution based on Apart from the well proven robust and
electricity MDC system high quality mechanical design, special
ª Suitable for all kinds of environments focus has been put on an ultra low power
electronic design to ensure a long battery
ª Highly scalable
lifetime. An interchangeable battery,
ITRON ENTERPRISE EDITION (IEE): indication of charge state and a low power
warning lamp further improve field support.
Meter Data Management
With a design preventing reversed
ª Robust integration using service-
operation and protection against magnetic
oriented architecture
tampering and backflow, maximum
ª Accurate validation, estimation and editing attention has been paid to provide a safe
ª Broad set of AMI interaction and controls concept.
ª Scalability Further examples to be mentioned are
ª Flexible role-based security provisions the encrypted data transmission
ª Integrated Microsofttm queuing (AES-128), the choice to enable user
technology interaction when opening the integrated
valve (option) and implemented leakage
REVENUE PROTECTION detection mechanisms during valve
The supported 2-way communication opening process (automatic closure for
allows more frequent periodic or instant detected flow rates above 15l/h).
remote meter readings, which ensures
together with the optional temperature EASY INSTALLATION
compensation more accurate billing and Together with the standard M-Bus
shorter cash collection cycles. discovery process, tools and manuals are
Alarms that can be read remotely include provided to support an easy installation.
excess maximum flow rate threshold For an even more installation convenience,
(programmable) and tampering attempts. managed services are available.
Together with the historic data stored, load
profiles can be built at data management
level (IEE) to control and optimize the gas
infrastructure.
The optional integrated valve makes new
pay-as-you-go contracts possible and
further reduce unbilled revenues.

“E” SERIES 111


“e” series portfolio
Product Sizes Description
Residential
RF1 e SW G4, G6 RF1 gas meter with electronic index and wired M-Bus
RF1 e WL G4, G6 RF1 gas meter with electronic index and wireless M-Bus
RF1 eV SW G4, G6 RF1 gas meter with electronic index, wired M-Bus and
integrated valve
RF1 eV WL G4, G6 RF1 gas meter with electronic index, wireless M-Bus and
integrated valve
Commercial and Industrial
ACD e SW G10, G16 ACD gas meter with electronic index and wired M-Bus
ACD e WL G10, G16 ACD gas meter with electronic index and wireless M-Bus

G25 e SW G25 G25 gas meter with electronic index and wired M-Bus
G25 e WL G25 G25 gas meter with electronic index and wireless M-Bus

SMART METERS “E” SERIES


Residential M-Bus
Master/data
concentrator

RF1 e SW RF1 e WL

Commercial & Industrial

ACE 4000 GPRS


electricity meter

ACD e SW G25 e SW

Smart Meters “e” series


The Itron Smart “e” series meters are the result of combining more than 100 years
of diaphragm meter engineering experience with the latest high quality electronic
and communication technologies.

112 GA-e-series-EN-V3.0-2011.08
“c” series
Smart Meters - Field Tested, Future Ready

To make the most of their resources, KEY BENEFITS


today’s natural gas providers need ª 100% reliable index transmission
accurate, reliable metering to measure ª Pre-equipped for future
usage, and they need to operate as communications needs (M-Bus,
efficiently as possible. The result of more OMS, DSMR, ZigBee®, Radian…)
than 100 years of diaphragm metering ª Proven technology - over
experience combined with patented 4.8 million devices installed
Cyble communications technology, Itron’s worldwide, with a maximum
variance of 200 liters per
“c” series meters provide high-quality
4.000.000 liters (99.996%)
measurement and communications
ª Compliant with international and
flexibility for today and tomorrow.
local regulations

Undamped oscillation Damped oscillation

1
2

3
Coil Coil

1 1
2 2

3 3

SPECIFICATIONS knowledge to shape your future 113


Building Blocks of Itron’s ECO series
The “c” series is part of Itron’s complete “eco” portfolio which address today’s and
future energy resource and environmental challenges.

Key Advantages of “c” series


GALLUS, AnyQuest &
RF1,
ª 100% reading accuracy between index
EverBlu Cyble,
Mechanical read and RF read
ACD G1.6, Cyble M-Bus,
G10/G16,
index, ª Safe against magnetic tamper
inductive Cyble OMS
G25/G100, (wired/ ª Set of daily growing communication
pulse
RPDs, wireless), modules
Turbines Cyble Zigbee ª 20 years of experience
ª Long life, robust and waterproof
Base Meter Index Communication
Module products (IP68)

HIGH RELIABILITY
With the unique, patented principle of Cyble technology, the meter index and the
remote index are always identical. The integrity and the reliability of this data is key for
use in billing applications:
ª The register is equipped with a non magnetic target. Hence, magnetic tampering is
impossible and the meter is insensitive to 2500 gauss magnets (non-magnetic metal
plated sector)
ª The Cyble target does not influence the metrology of the meter. The register is
insensitive to vibrations (to send an output signal, a complete revolution must be
completed).

TARGET DETECTION
Cyble MIU measures the dampening of the Electromagnetic field:

Coil Oscillations

Coil Coil

Undamped coil Damped coil


The target is not under the coil The target is under the coil

If there is no Target in front of the coils of the Cyble MIU, the generated oscillation is
self damped within a time T. When the Target is in front of a coil of the Cyble MIU, the
induction creates a surface current in the Target (called an eddy current) which has the
effect of opposing the induction and therefore dampens the oscillation faster, within
time T’ < T.

114 “C” SERIES


Cyble Sensor ATEX ª Can take into account the direction of
Cyble Sensor generates pulses similar the flow (backflows).
to the one generated by Reed Relays. ª Up to 4 signals can be created
The main differences are that the pulses including flow direction and cable cut
coming from Cyble Sensor are: (depending on the version).
ª Electronically generated
(hence perfectly squared shape)
ª Not sensitive to magnets (Reed Relays
generate pulses with magnets turning
under a mechanical relay)

“c” series portfolio


Product Sizes Description
Wired Communication Modules
M-Bus Cyble 92x57x35 Cyble module with M-Bus protocol to facilitates the
integration of Itron meters into an M-Bus network.
Cyble Sensor ATEX 92x57x35 "Cyble Sensor module generates pulses similar to
the one generated by Reed Relays."
OMS Cyble 92x57x50 Cyble module with wired communication
interface and OMS specification.
Wireless Communication Modules
AnyQuest Cyble Basic 92x57x50 Cyble module with radian protocol and basic
AnyQuest features for mobile meter reading.
AnyQuest Cyble Enhanced 92x57x50 Cyble module with radian protocol and AnyQuest
Enhanced features for mobile meter reading.
EverBlu Cyble Enhanced 92x57x50 Cyble module with EverBlu protocol forfixed
network applications.
OMS Cyble 92x57x50 Cyble module with wireless communication
interface and OMS specification.
DSMR Cyble 92x57x50 Cyble module with wireless communication
interface and DSMR specification.
Meters with Cyble totaliser
ACD G1.6 G1.6 ACD meter with Cyble totaliser
GALLUS G4, G2.5 GALLUS meter with Cyble totaliser
RF1 G4, G6 RF1 meter with Cyble totaliser
ACD G10-G16 G10-G16 ACD meter with Cyble totaliser
G25-G100 G25-G100 Meter with Cyble totaliser
Rotary Meter Delta G10-G650 Rotary meter with Cyble totaliser
Turbine meter Fluxi 2000/TZ G65-G6500 Turbine meter with Cyble totaliser
Quantometers MZ 100m³/h Quantometer with Cyble totaliser
10000m³/h
For more information on the meters with Cyble totaliser, contact your local sales representative.

“C” SERIES 115


CYBLE MODULES
A
AnyQuest Cyble M-Bus Cyble
M
T Itron AnyQuest
The C
Cyble communication
C
Cyble radio module modules have been
m
offers superior
o d
designed to meet
rreading distance th
the requirements of
and enhanced data ca captures. These all water management utilities wanting to
additional data enable the utility to improve read their water meters remotely.
productivity and bring extra services to The Itron Cyble M-Bus module offers
customers. enhanced data such as 13 fixed date
EverBlu Cyble
E readings, back flow and leakage detection.
T EverBlu Cyble
The This additional data enables the utility to
iis compatible with improve productivity, bring extra services
EverBlu fixed
E to customers and reduce water losses.
network for daily
n Cyble M-Bus facilitates the integration of
data
d t ttransmission
i i or on-request meter Itron water meters into an M-Bus network.
reads. In gas applications, EverBlu Cyble
OMS Cyble
O
transmits not only the 24 hourly meter
reading indexes, but also a dvanced T OMS Cyble
The
information such as tampering alarms, etc. collects data from
c
metering devices for
m
Alternatively, its data can also be collected
electricity and gas
e
using AnyQuest mobile reading system.
as well as heat and water
wa consumption.
Thus allowing upgradability from one
It can communicate to or with a MUC via
system to the other.
one of the primary communication
interfaces to transfer subsets of this data
to the ‘AMM back office systems’ for
billing, servicing or other purposes.

ASSOCIATED SYSTEMS of customer relationship management,


distribution asset optimization, and
Mobile Meter Reading - AnyQuest demand-side management.
AnyQuest is a mobile data collection Itron offers a wireless mesh point-to-
solution comprised of multiple multipoint communication system adapted
components working together to create to all kinds of urban and suburban
and collect enhanced data. It includes environments. It is suitable for multi-energy
high performance radio modules, rugged applications involving water, gas and heat
handheld terminals, user-friendly mobile metering.
reading software and host software to
Advanced wireless meter modules create
transfer data from and to third party
accurate data. The system automatically
systems.
collects these data and is designed with
Fixed Network Application - EverBlu automatic node path reconfiguration to
achieve maximum reliability. Hence
EverBlu is more than just an Automatic
providing energy and water providers
Meter Reading system. It opens the way
with comprehensive valuable information.
for a wide range of applications in the fields

116 “C” SERIES


Mobile Meter Reading - AnyQuest

433 MHz
868 MHz
GPRS
Ethernet

Meter Utility Mainframe


Communication PC with (Billing System / Customer
Unit Collector Access Point FTP Server EverBlu™ Software Information System)

Fixed Network Application - EverBlu

“C” SERIES 117


Advanced Meter Infrastructure
Wired and wireless Fixed Network System
M-Bus, specified in a European norm, has become the system of choice when building
small scale wired fixed network systems for all meter types (water, gas, heat and
electricity).
Used by utilities as well as service companies, Itron M-Bus Cyble modules offers the
best of M-Bus standard with an user-friendly interface. It provides access to the
advanced data collected from Itron meters.

Water Gas Heat Electricity Data Collection Utility Mainframe


Software (Billing System / Customer
Information System)

1 2

118 “C” SERIES


AVAILABLE CYBLE METERS

Residential Commercial & Industrial

GALLUS
ACD G10-G16

Fluxi 2000/TZ
Turbine Meter Range

GALLUS Alu version


G25-G100

RF1
Delta Rotary Meters MZ Quantometers

Smart Meters “c” series


The Itron Smart “c” series meters are the
ACD G1.6 steel case version result of combining more than 100 years of
diaphragm meter engineering experience
with the latest high quality electronic and
communication technologies.

“C” SERIES 119


120 GA-c-series-EN-V2.0-2011.08
“o” series
Itron Radio Module KEY BENEFITS
Gas Module For Automatic Meter Reading ª Plug and play solution
ª Consistent reliability
Itron radio module is a device connected to ª ATEX Zone 1 (compliant “ia”)
a pulse emitting meter. The module counts, ª Compatible with Mobile meter
memorises and transmits, on demand, the reading and fixed network
consumption pulses of the meter. applications

MODULE DESCRIPTION BENEFITS OF WIRELESS SOLUTION


The “o” series is a stand-alone module ª Radio meter reading increases the
which can be shipped to retrofit reading speed.
previously installed meters (meter with ª The data reliability is improved
pulse emitter index). significantly by avoiding typing or
Retrofit is easy and safe, guaranteeing writing errors.
immediate use by the meter reading ª The radio reading also opens the
system in place, provided it complies accessibility to all meters even if the
with the Radian protocol. customer is absent or the meters are
The module is designed for optimal data installed in hard to read locations.
integrity. It does not require wiring as
needed with a stand-alone radio module
and so allows for a quick and easy direct
interface to the meter index. Also the
quality of the pulse interface is OIML
compliant with a maximum drift between
the mechanical and logical index inferior
to 0.05% over the life of the module.

SPECIFICATIONS knowledge to shape your future 121


ANYQUEST / EVERBLU ENHANCED ª The module case is made of extra
WORKING TECHNOLOGY robust plastic material which makes it
ª Based on the proven design of resistant to shocks and UV-lights.
AnyQuest / EverBlu Cyble, the “o” series
ADVANCED FUNCTIONS
Enhanced works reliably even in harsh
environments. AnyQuest / EverBlu o series Enhanced
provides powerful smart functions, adding
ª It counts, memorises, analyses and
value for your AMR / AMI applications:
transmits on request, the consumption
data of any meter via, mobile or fixed ª Up to 181 consumption intervals
network reading systems. (24 hourly indexes when used in
EverBlu / UniGate application).
ª The AnyQuest / EverBlu “o” series is
compatible to the open RADIAN radio ª Tamper alarm
protocol. ª End of battery lifetime indicator
ª Metering intelligence functions:
CONSISTENT RELIABILITY
• meter oversized
With the long experience in battery powered
• meter undersized
metering products, Itron knows that
reliability is key for customer satisfaction. • meter blocked
• peakflow log + 13 monthly alarms
ª Pulse emitters have been upgraded
with a new Reed Switch technology • 2 x time of use indexes
and are tested 100% for quality on a • Critical alarms are date stamped
dedicated test bench in the factory.
ª The unit is protected from harsh
environments (IP67) and it can be fitted
to meters located indoors or in meter
cabinets outdoors.
Mobile Meter Reading AnyQuest

122 “O” SERIES


Technical Specifications
Radio Frequency Features
Protocol Radian / EverBlu
Modulation Frequency Shift Keying
Frequency & power 433.82 MHz; ≤ 10 mW ERP
Transmission Symmetrical 2 way communication

Functional Specifications
Dimensions 103 x 92 x 62 mm
Battery lifetime (min) 15 years mobile reading use
10 years fixed network use (EverBlu/Unigate)
Case protection IP 67
Relative humidity 0 to 100%
Operation temperature* -10°C and +55°C
Min.: -10°C to +5°C (< 15 days/year)
Max.: +30°C to +55°C (< 15 days/year)
Storage temperature +5°C to +35°C < 1 year
Temperature variation max. ±20°C/hour
Transport temperature Between -20°C and +5°C < 72 hours continuous
Between +35°C and +70°C < 72 hours continuous
Otherwise refer to storage condition in between
Temperature variation max. ±20°C/hour
Conformity CE Certified in accordance with the European R&TTE directive (1999/5/EC)
Intrinsic safety protection II 2G Ex ib IIA T3 [-25°C; +55°C]
* High Temperature (HT) version also available on request.

Fixed Network Application EverBlu

433 MHz
868 MHz
GPRS
Ethernet

Meter Utility Mainframe


Communication PC with (Billing System / Customer
Unit Collector Access Point FTP Server EverBlu™ Software Information System)

“O” SERIES 123


ANYQUEST SOFTWARE KEY BENEFITS
The AnyQuest software package allows ª Managing: Water, Gas & Heat / Cooling
comfortable, route-based radio reading radio data
for utilities. It includes AnyQuest Host ª Easy to use
and AnyQuest Mobile. ª Easy installation of AnyQuest Mobile on
AnyQuest Host manages the data the handheld computer
transfer between handheld computers ª Enhanced data & functionality
and the billing system.
ª Data quality
It also allows the technical interpretation ª Key Features
of the enhanced reading data by graphical
ª Manages the data transfer between
display and XML/CSV export function.
handheld terminal and billing system
AnyQuest Mobile is the easy way to
ª Graphical data display of consumption
learn mobile route software for radio and
keyed reading. ª Multi criteria filtering & sorting
With its functions for high and low ª Computer statistics
consumption warning and the enhanced ª XML & CSV transfer for further data
comment functionalities, the reader can processing
reduce significantly reaction time and cost.

AnyQuest Software

124 “O” SERIES


Enhanced functionalities

Volume index Volume index at time of reading

Volume index recorded at 4 preset dates


Preset billing date
(programmable)

History of up to 181 consumption intervals


Data-logging
(hourly,daily,weekly,monthly)

Registers consumption within a defined


2 Time-Of-Use Indexes
intervals of the year

Total consumption above a high flow-rate


Volume above threshold
threshold

Total consumption below a low flow-rate


Volume below threshold
threshold

2 x 13 monthly indicators if the meter is


Meter sizing indicators
oversized or undersized

Alarm if no consumption over a configurable


Meter stopped detection
period has been recorded

Alarm if > 1000 consecutive target turns in


Reversed meter detection
reverse flow have been recorded

Alarm if the radio module module has been


Module tamper detection
tampered

Log of start and end dates for last recorded


Alarm log
alarms

5 highest peak flow-rate values with date of


Peak flow-rates
occurrence

13 monthly alarms if the peak flow threshold


Peak flow alams
has been exceeded

“O” SERIES 125


126 GA-o-series-EN-V1.0-2011.07
Advanced Data
Collection KEY FEATURES
& BENEFITS
SATURNE ª Reduced O&M costs and
increased productivity by
operating one system for
Today’s fast paced energy market demands
interval data collection
effective and smart solutions to meet the and management
broad business challenges and varying data
ª Improved revenue from
collection needs that the industry is facing. improved integrity in
Saturne, a powerful advanced data collection interval data used for
and industry-proven system, brings the billing purposes
long-awaited answers to the challenge of ª Operational flexibility from
Advanced Metering Management by enabling a scalable solution that
state-of-the-art smart grid functionalities. can grow with your needs

A TRULY FLEXIBLE, MULTI-VENDOR, OPEN-ARCHITECTURE SOLUTION

Saturne is a true Multi-Fuel, Multi-Vendor Resulting from close collaboration with


and Multi-Segment advanced data leading energy market players, Saturne
collection solution that enables utilities allows utilities to provide end-consumers
to collect data and manage a wide range with detailed and accurate bills as well as
of residential and C&I meters. It is an value-added services that empower them
enterprise solution based on open to make more efficient use of energy.
standards and designed to provide a In addition to its unparalleled data
reliable, secure and highly scalable platform collection capabilities, Saturne also
that collects and processes meter data offers data management and analysis
such as load profiles, multi-tariff billing tools that ensure data integrity and
registers, meter status information, events process consistency throughout your
and alarms, among others. business.

SPECIFICATIONS knowledge to shape your future 127


In any smart grid initiative, flexibility, interoperability and flawless information exchanges
are key to successful deployment. Saturne has been designed to ensure perfect
metering communication regardless of the communication technology in place and to
anticipate infrastructure evolutions and future needs.

FUTURE-PROOF SCALABLE
Saturne’s multi-vendor and multi-fuel Saturne is a flexible, open solution that
proven capabilities provide total flexibility provides seamless integration with any
to utilities allowing them to dramatically enterprise-class system and offers easy
lower both implementation and operational interfacing with third-party applications
costs whilst anticipating technological using industry standards (XML, SOA)
and regulatory changes. thus minimizing cost of ownership.
With the ability to collect metering data To meet the requirements of the most
from residential and C&I meters through critical applications, Saturne has the
point-to-point connection or a gateway or ability to scale and support data handling
concentrator, Saturne is the ideal advanced and workload requirements, from a few
data collection solution for utilities that thousand C&I meters to millions of
want to collect and normalize data in a residential meters.
centralized and secure repository. Saturne leverages XML messaging and
Saturne also handles multiple web services architecture allowing for
communication technologies including extensive automated support for large
PSTN, GPRS and PLC and supports scale roll-outs, installation and
both push and pull communication. All of commissioning. As legislations evolve,
these combinations can be managed in new processes can be safely added to
the same installation or network. prevent vendor lock-in.

128 SATURNE
CUSTOMER VALUE
Saturne provides a dynamic and solid reporting infrastructure, enabling a platform for
operational reports and dashboards where utilities can have detailed information to
support mass rollouts, exceptions management and topology management without
compromise the transactional environment. Based on its flexible architecture, information
can be accessed and distributed via different ways both for end users or third party
applications.

SATURNE 129
130 EL.113.0-EN-04.12
ACD G10-G16
G25-G40
G65-G100
These diaphragm meters can be consulted
in the Standard Commercial & Industrial metering section.

See ACD G10-G16 See G25-G40 See G65-G100


on page 47 on page 55 on page 63

SPECIFICATIONS knowledge to shape your future 131


132
CybleTM KEY BENEF
BENEFITS
EFITS
ITS
Sensor ATEX
X ª High reliability for remote
reading.
A Smart Pulse Transmitter for Gas Meters ª Magnetic tampering is
impossible.
The Cyble Sensor ATEX has been designed ª Easily retrofittable
specifically for gas utilities needing to connect (no breaking of seals) onto
meters equipped with the
electronic devices with a LF pulse input, such
Itron universal totaliser.
as volume converters to a gas meter.
ª 10 years Itron Cyble
It can be mounted at any time onto any Itron experience;
meter equipped with an Itron universal totaliser. 1 million installed onto
It provides a completely flexible solution for Itron water meters (as of
current or future remote reading technologies. September 2006).

PRINCIPLE OF OPERATION Target absent 1


The Cyble Sensor ATEX works as follows:
ª A Cyble target is fitted as a standard
into the Itron universal totaliser. It rotates Coil
proportionally to the registered volume 3 2
of gas.
T > T’
ª 3 coils fitted in the Cyble Sensor ATEX
detect the rotation of the target by
measuring the change of induction in Target present 1
front of each coil.
ª An electronic board records the
complete rotation of the target. This Coil
detects and compensates for any 3 2
backflows: the meter index and remote
register are identical. When a complete T’
rotation is validated, a pulse is sent out
at the output of the Sensor.

SPECIFICATIONS knowledge to shape your future 133


APPLICATIONS The Cyble M-Bus, RF and Coder presented
The Cyble Sensor ATEX can be mounted are also available for other applications.
onto the Itron Fluxi 2000/TZ, Delta and They can also be used to ensure a
MZ meters. reliable remote reading of the meter.
It can be used to ensure reliable
transmission of the non-corrected volume
from the meter to the Itron Corus volume Grey
converter or to any volume converter Green
Connection: White
using a standard low frequency input.
Yellow

Technical Specifications
Intrinsic safety approval L.C.I.E. 06 ATEX 6044 X
Intrinsic safety level II 1 G Ex ia IIC T3
Signal output Ui ≤ 15 Volt
Ii ≤ 900 mA
No polarisation to be observed: wires white and yellow
Type dry contact equivalent
Anti-tampering (AT): wires grey and green.
Cable length 5m
Power supply Lithium battery - not replaceable
Life time > 12 years (in normal applications within the specified
temperature range)
Working temperature -25°C to +55°C
Storage temperature -25°C to +55°C
Protection IP68
E.M.C standards EN 61000-6-2, EN 61000-6-3, EN 60947-5-6

OTHERS TYPES OF CYBLE SENSORS AVAILABLE FOR USE IN NON-ATEX AREAS.


Cyble Sensor 5 wires: Cyble RF:
it provides the same functionalities as the it provides all benefits of a wireless
Cyble Sensor ATEX and additionally has: solution; higher data acquisition speed
ª 1 signal for the flow direction and complete accessibility to all meters
even if the customer is absent.
ª 1 pulse output without backflow
compensation Characteristics:
Protocol: RADIAN
Cyble M-Bus:
Frequency carrier: 433.82 Mhz
it can be used to integrate the Itron gas
meters into a M-Bus network. In addition
to the meter reading, Cyble M-Bus
also provides smart functions such as For more details about these 3 Cyble
database management. Sensors, please consult the relevant
brochures produced by the Itron Water
It provides all relevant data compliant to division online at www.itron.com
EN 1434.

134 CYBLE™ SENSOR ATEX


Installation of the Cyble Sensor ATEX
onto the meter:

Fluxii 2000/TZ fitted


Fl fitt d with
ith the
th universal
i l
totaliser and the Cyble Sensor ATEX
1) Mounting

2) Screwing

3) Sealing

CYBLE™ SENSOR ATEX 135


136 GA-Cyble-Sensor-ATEX-EN-V2.0-2011.12
CORUS
Gas Volume Converter

CORUS is an electronic volume converter KEY BENEFITS


dedicated to commercial and industrial ª T, PT, PTZ Gas Volume
applications. It converts the actual volume Converter
measured by the gas meter to reference ª Conforms to European
conditions. Thus, CORUS is a key element in Standard EN 12405-1 and
the whole Itron chain, from the meter to billing EN 12405-1/A1
data. ª MID approval
ª ATEX approval for installation
in hazardous area (zone 0)
CORUS uses the measured working values of volume,
pressure and temperature to provide: ª Large integrated database
ª Compressibility according to
ª the converted volume
AGANX19, S-GERG, AGA 8
ª the conversion factor (gross or detailed methods)
ª the compressibility factor (several formulas available) or Table of Z
ª a large database ª RS 232 and optical port for
ª pulse retransmission local / distant communication
ª High accuracy on the whole
DESCRIPTION temperature / pressure range
The volume registered by the meter is converted to ª Autonomous or external
reference conditions using the formula : power supply
Pm Tb Zb
Vb = Vm ª Large graphic display
Pb Tm Zm
ª Possibility to download new
Terminology firmware in the field
Vm unconverted volume registered by the meter ª Internal optional slot for “Ex”:
Vb converted volume in reference (base) conditions
Tm gas temperature in operating conditions • PSTN modem
Tb reference (base) temperature • RS-485 ports (x2)
Pm gas pressure in operating conditions
• 2nd pressure sensor input
Pb reference (base) pressure
Zm compressibility factor in operating conditions
Zb compressibility factor in reference (base) conditions

SPECIFICATIONS knowledge to shape your future 137


DESCRIPTION (cont’d) Inputs /
Outputs
CORUS is built in an IP65 enclosure, for
wall or meter mounting. Thanks to its
accurate piezo-resistive pressure sensor
and its 4 wires PT1000 temperature
probe, CORUS provides an accurate
conversion on the whole temperature
range. RS 232
External Power Supply
CORUS non-metrological firmware can (Option)
be updated in the field without stopping Digital Input 2
operations and without breaking the or Digital Output 2
metrological seals (MID). Its large Digital Input 1
integrated database can be customised or Digital Output 1
to fit the customers’ needs. Recorded Meter Cable (LF1 / LF2 / Tamper)
T Probe
data and number records can be freely
P Sensor
set.
Connection slot (option)
CORUS is the base element of a
complete and extremely flexible system, ª Remote reading solutions through
perfectly adaptable to the customer’s PSTN, GSM, GPRS or TCP/IP with
requirements: several integrated communication
ª Consumption, pressure, temperature protocols:
monitoring through its large database • IEC-62056-21 (IEC-61107)
for billing purposes • MODBUS RTU
ª Monitoring functions for gas stations • IDOM

TECHNICAL FEATURES
Approvals
ª MID:
• Module B – T10114 rev.1
• Module D – n° LNE13281 rev.0
ª Metrology: approval according
to EN12405-1 and EN12405-1/A1
(European Standard)
ª ATEX: device of category 1 approved
to be used in hazardous area zone 0,
ia IIC T4 classification (zone1, ia e mb
IIC T4 classification with internal PSTN
modem)
ª CE Marking: compliant with 89/336/
EEC (EMC), 94/9/EC (ATEX) and
FLUXI 2000 meter with CORUS 2004/22/EC (MID Directive)

138 CORUS
Temperature Sensor Display and Keyboard
ª Platinum PT 1000 (1000O at 0° C) probe ª Graphic display
ª Class A accuracy according to EN60751 ª All metrologic data and alarm status
ª Casing: stainless steel tube for insertion available
into a thermowell (Ø 6 mm) ª Translatable messages to any language
ª Cable length: 2.5m or 0.8 m ª Specifics icons for application
Pressure Sensor ª Possibility to show graphs for P, T, Z, C,
Qm, Qb, P2
ª Absolute pressure sensor designed for
ª 5-Button keyboard
CORUS application (gauge pressure
sensors available on request) ª Possibility to program main parameters
by keyboard
ª Silicon piezo-resistive sensor
ª Possibility to display the whole database
ª Overpressure up to 150 % of Pmax
ª Available in 3 ranges:
Graphic Display
• 0.9 to 10 bar absolute
• 3 to 30 bar absolute INDEX VALUE ALARM DATA CONFIG
• 7.2 to 80 bar absolute
ª Connection adapter: ¼” BSP (Gas) male Unconverted volume :
ª Typical Accuracy: <0.15 %rd over the 19348725.000 m3
whole pressure range
Volume Input Converted volume :
ª Dry contact, passive LF Reed type switch 24284651.283 Nm3
ª Maximum frequency 2Hz
Possibility to translate messages
ª Programmable input pulse weight
(0.001, 0.01, 0.1, 1, 10, 100) INDEX VALUE ALARM DATA CONFIG
ª Second LF input for coherence function 4.2
ª Associated tampering detection input
ª Cyble® sensor ATEX module
Compressibility
ª Main formulas available: 4.0
• S-GERG P (bar) 4.025
• AGA8 Gross method 2
Graphic display function
• AGA8 Detailed method
• AGANX19 Battery supply mode and status
• AGANX19 modified
External supply mode and status
• Table of Z (16 coefficients formula)
• Fixed Z (PT conversion) Alarm presence (active, memorized)
Accuracy Incoming pulse from meter
According to EN12405, overall accuracy Pressure alarm (active, memorized)
on conversion factor is better than ± 0.5 Temperature alarm (active, memorized)
% at reference conditions and better than
1 % at rated operating conditions. Communication in progress
ª Typical accuracy better than ± 0.2 % Specific icons for CORUS applications

CORUS 139
Digital Inputs (On/Off1, On/Off2,
Tamper) Accessories
ª Station monitoring ª Configuration software (Wincor)
ª Normally open or normally closed ª Thermowell
programmable status ª 3-Way pressure connection kit
ª Connection to any On/Off signal type ª Optical head
(Station door contact, safety valve ª ISB+
position, pressure switch,..) in ª External supply “Ex” module
hazardous areas.
ª F/I Converter for 4/20 mA output
Digital Outputs ª Additional boards:
2 Digital, isolated ouputs fully • PSTN modem
programmable as: • RS-485 ports (x2)
ª Unconverted volume pulse • 2nd pressure sensor input
retransmission ª Cyble® sensor ATEX module
ª Converted volume pulse retransmission
ª Alarm retransmission
ª 4/20 mA output (through an external F/I
“Ex” module)

Alarms
The following alarms are managed by the
CORUS:
ª Temperature (Min, Max, Sensor failure)
ª Pressure (Min, Max, Sensor failure)
ª Conversion factor (Min, Max)
ª Unconverted and converted flow-rate
(Min, Max)
ª Coherence
ª Interval consumption
ª Tamper
ª On/Off 1 and On/Off 2
ª External power supply outage
ª Warning thresholds (T, P, P2) DELTA meter with CORUS

140 CORUS
SYSTEM OVERVIEW
Distant communication (Connection to CORUS RS 232 or RS 485 port)
GSM/GPRS data collection through FOCUS+ GSM/GPRS Modem
HAZARDOUS AREA SAFE AREA

CORUS FOCUS+ Supervisor+

Direct connection to standard devices (RTU, TCP/IP interface, standard modem, PC...)

Supply
+9/24 VDC

RS-232 RS-232
RTU or RS-485 ISB+ CORUS
SAFE AREA HAZARDOUS AREA

Distant communication through internal RS-485 board (up to 4 CORUS on the same bus)
RTU or modem with RS-485 port CORUS CORUS
ISB+

CORUS CORUS

RS-485 RS-485
≤ 200 m

Distant communication through internal “Ex” PSTN Modem

OK

1 2

CORUS 141
Upstream pressure monitoring with P2 internal board Local communication
through optical port
Gas regulator CORUS

P2
Volume
Optical Head
Upstream
pressure
PC

Meter (Delta/Fluxi) Note book

Technical Specifications
Overall Accuracy of the Maximum Error < 0.5 % - Typical Error < 0.2%
C Factor
Conversion Range Pressure: 0.9 bar to 80 bar - Temperature: according Z formula
Power Supply Battery or external (through Ex module)
Autonomy 5 years (battery version) in typical conditions
Ambient Temperature -25° C to +55° C
Range
Enclosure IP65 polycarbonate box
Volume Input LF input (2 Hz max); Reed switch type or Cyble® sensor ATEX module
Second input for coherence function

Temperature Sensor PT1000 class A; 4 wires

Pressure Sensor [0.9 /10] bara, [3 /30] bara and [7.2 /80] bara
Ranges (gauge pressure sensors available on request)
Pressure Sensor Type Piezo-resistive sensor
Outputs 2 Channels fully configurable as pulse, alarm or 4/20 mA*
User Interface Graphic display + 5 button keyboard
Communication Optical serial port and RS232 serial port
Metrol. Cables Length 2.5 m or 0.8 m
(P, T, LF)
Option Internal “Ex” PSTN modem (V32bis)
RS-485 dual port board
P2 second pressure input board
* through external F/I converter

142 CORUS
DATABASE HAZARDOUS AREA SAFE AREA
CORUS provides 6 different logs:
ª Hourly log: last 1440 hours (2 months)
ª
OK

Daily log: last 124 days (4 months)


ª Monthly log: last 24 months CORUS
Volume pulse
ª Interval log: L 20 m
Ex isolator
or alarm
220 V AC
• from 3100 to 5900 records according or 24 V DC
Volume pulse
selected data L 20 m
BSI
Ex isolator
BSI
or alarm
220 V AC
• interval programmable from 1 to 60 mn or 24 V DC

ª Events log: last 800 events


Configuration with pulse outputs
ª Parameters log: last 200 records
HAZARDOUS AREA SAFE AREA
POWER SUPPLY
ª Battery operating or external supply OK

mode (mains or solar)


ª Battery: CORUS 9 V DC Ex 220 V AC
Power Module or 24 V DC
• Specific 17 A.h lithium battery pack
F/I 4/20 mA
including all required protections for Converter Data 1*
L 10 m
intrinsic safety 220 V AC
or 24 V DC

• Pack can be changed in hazardous F/I


Converter
4/20 mA
L 10 m Data 2*
area without interrupting the normal 220 V AC
or 24 V DC
operation of the device * P, T, Qu or Qc

• 5 years autonomy in typical conditions Configuration with 4 / 20 mA outputs


ª External power:
• External “Ex” specific supply module Dimensions
required providing 6 to 12 V DC to 222
the CORUS 206

• Main battery (17 A.h) remains in the


product, acting as backup battery in
case of mains cuts.
42
145
59

Information to be specified
when ordering: 4 holes 28 20
Ø 5.2
ª Pressure range
86
ª Formula for Z calculation 49
ª LF input cable type
ª Battery or external supply
ª Metrologic cables length
ª Language for display
ª Accessories
ª MID sealing
25

CORUS 143
144 GA-CORUS-EN-V2.0-2012.04
Corus Compact
Gas Volume Converter

The Corus Compact is Itron’s latest-generation KEY BENEFITS


electronic volume converter (EVC), designed ª Operational efficiency with
specifically for diaphragm and small-range RPDs. wireless data collection
Its compact size fits to the limited available ª Deployment flexibility
space of small cabinets. Corus Compact has ª Low operating costs
been developed to comply with all metrological
requirements of MID (EN12405-1 and /A1), but
also with the functional requirements of ARG
155-08 and CIG UNITS 12291. Data transmission
to a central system is achieved via an external
GSM/GPRS modem, creating a remote reading
solution that is both simple and cost-effective.

APPLICATION DESCRIPTION
Gas electronic volume converter for Despite its small size, the Corus Compact
diaphragm meters and small-range RPDs contains the technology required for
accurate gas volume conversion, as well
FEATURES as for transmitting that data to the central
ª T, PT, PTZ gas volume converter system through a GSM/ GPRS network.
ª Pressure range: 0.7 / 6 bar abs. Corus Compact and its modem are
ª Compact size housed in IP 65-rated enclosure. Their
small size and friendly user interface use
ª Remote and local firmware download
a graphic LCD display and offer easy
capabilities
installation in the field. Approved for use
ª Five year battery life in zone 1 hazardous areas, both Corus
ª External GSM/GPRS modem and Focus Compact can be installed
(Focus compact) inside a station cabinet, limiting installation
ª DLMS/Cosem communication costs and vandalism risks.

SPECIFICATIONS knowledge to shape your future 145


DESCRIPTION (cont’d) TECHNICAL FEATURES
The Corus Compact creates and Approvals
maintains different consumptions logs—
ª MID certification applied to converter
as well as event and parameter
and according to EN12405-1 & A1
logs—which are useful for diagnostic
(European standard)
purposes; the database for these logs is
compliant with UNITS 12291-4. Data can
be transmitted via GPRS at
programmable intervals using an
external, dedicated modem (Focus ª ATEX : Device category 1 approved to
Compact). be used in hazardous area zone 1,
II 2(1) G Ex ia IIA T3 ZELM 11 ATEX
The solution with 2 separate enclosures 0469X
for EVC and modem offers important
ª CE marking compliant with 89/336/EC
benefits vs an integrated solution:
(EMC), 94/9/EC (ATEX) and 2004/22/
ª Maximal flexibility in terms of space EC (MID directive)
occupation inside small cabinets
Accuracy
ª Installation flexibility for better GSM
signal reception ª According to EN12405, overall
accuracy of the conversion factor of any
ª Simplified maintenance
measuring point is better than:
Corus Compact utilizes the DLMS/ • +/- 0.5% at reference conditions
Cosem communication protocol—a • +/- 1% at rated operation conditions
worldwide standard in the metering
ª Typical accuracy +/- 0.15%
world.
Volume input
An internal communication port allows
flexible data transmission via wired or ª Dry contact, passive LF Reed type
radio interfaces to external modem/ switch or dry contact
concentrators for further transmission to ª Compliant with Cyble® sensor ATEX
central system. module
Internal batteries provide an average of ª Maximum frequency 2Hz
five years of uninterrupted service under ª Programmable input pulse weight
typical usage conditions, including daily (0.001, 0.01, 0.1, 1, 10, 100)
data transmission to a central system. ª Associated tampering detection input
Batteries are field-replaceable and can
Temperature probe
be exchanged without breaking the
metrology seal. ª Platinum PT1000 (1000 ohms at 0°C)
probe
ª Cable length: 3 m
Pressure transducer
ª Absolute pressure sensor with range
from 0.7 to 6 bar absolute
ª Typical accuracy better than 0.15% of
the measurement point over the whole
pressure range
ª Cable length: 3 m

146 CORUS COMPACT


Compressibility Data base and Logs
ª Main formulas available: Corus Compact provides six different
• S-GERG88 logs:
• AGA8 Gross Method 2 ª Hourly log: Last 2048 records (85 days)
• AGANX19 modified ª Daily log: Last 512 records
ª Monthly log: Last 48 records
User interface
ª Billing log: Last 256 records
ª Graphic display
ª Events log : Last 4096 events
ª All metrological data and alarm status
ª Parameters log : Last 4096 events
available
ª Possibility to program main parameters All data are stored in none volatile
ª Translatable message to any language memory and integrity of each record is
controlled by checksum.
Digital outputs
Tariffs
ª 2 digital isolated outputs fully
Corus Compact implements time of use
programmable as retransmission of:
(TOU) tariff management:
• Pulse converted volume
ª 3 tariff registers
• Pulse Converted volume ª Tariff switchable up to 5 times per day
• Alarm ª Management of 25 special days over a
6 month period.
Power supply
ª Operating on C cell Lithium battery User Access

ª Battery change feasible in hazardous Read/write access to parameters and


area without interrupting the normal Corus Compact database are controlled
operation of the device according to:
ª Access privilege defined according to
ª Five year battery life expectancy under
user profile
standard conditions
ª 6 different user profiles
ª Battery can be replaced by external
power input board with back-up ª 10 users maximum per user profile with
battery (available in 2012) at least 1 administrator

Focus Compact GPRS Modem


Alarms
ª Installation possible in hazardous area
Corus Compact manages several alarms (Focus Compact ATEX variant available
including: Q1-2012)
ª Legally relevant alarms ª User-friendly interface for simplified
(out of range temperature and pressure commissioning and handling that
measurement, sensor failure, includes
tampering) • Indicators (such as GSM reception
ª End of battery life level)
ª Overflow • Diagnostic counters (such as GPRS
ª Time synchronization error data traffic)
ª Memory check error • Alarms (such as SIM card issues)

CORUS COMPACT 147


ª Quad-band GSM/GPRS modem, Configuration software
ª Five year battery life expectancy with Wincor software is used for local
daily communication (GPRS) communications through the optical port
ª Field-changeable battery of Corus Compact or its modem to:
ª External power supply input (Focus ª Configure general settings,
model only) ª Displays real-time (or ”live”) data,
ª Dlms/Cosem protocol (IEC 62056-53) ª Displays the different logs,
ª Extract and export of the database
of Corus Compact and product
configurations

SYSTEM OVERVIEW
Communication with Focus Compact installed in safe area

HAZARDOUS AREA SAFE AREA

p
CORUS Compact p
FOCUS Compact

GPRS
RS-232 RS-232
network

Solar panel
or
ALIS 200
Mains
M

Communication with Focus Compact installed in hazardous area (Planned Q1-2012)

HAZARDOUS AREA SAFE AREA

p
CORUS Compact p ATEX
FOCUS Compact

GPRS
RS-232
RS- 32
network

148 CORUS COMPACT


Technical Specifications
Corus Compact
Overall accuracy of the Maximum Error < 0.5 % - Typical Error < 0.15%
C factor
Power supply Battery with 5 years autonomy (battery version) in typical conditions
Temperature range Ambiant temperature: -25°C to +55°C
Gas temperature: -25°C to +70°C
Enclosure IP65 polycarbonate box
Volume input LF input (2 Hz max) with 1 anti-tampering input
Temperature sensor PT1000; (3 meters cable length)
External Pressure Pressure range: 0.7 bar to 6 bar
sensor 3 meters cable length
Outputs 2 Channels fully configurable as pulse or alarm
User Interface with graphic display
Communication RS232 port can be replaced by another port (RS485, radio,...)
ATEX approval Approval certificate from NMI T10388
ATEX approval II 2(1) G Ex ia IIA T3 ZELM 11 ATEX 0469X

Focus Compact
Power supply Battery with 5 years autonomy with daily communication
Features Quad-band GSM/GPRS modem,
Dlms/Cosem protocol
Enclosure IP65 polycarbonate box
Antenna Internal or external
Ambient temperature -25° C to +55° C
range
User Interface with graphic display
Communication - Optical port for local configuration
- RS232 for communication with Corus Compact
(can be replaced by another port like RS485)
- GPRS modem for remote communication
ATEX approval II (1) G [Ex ia] IIA ZELM 11 ATEX 0461X

OPERATING PRINCIPLE Terminology


The volume registered by the meter is Vm unconverted volume registered by the meter
Vb converted volume in reference (base)
converted to reference conditions using
conditions
the following formula: Tm gas temperature in operating conditions
Vb= Vm x Pm/Pb x Tb/Tm x Zb/Zm Tb reference (base) temperature
Pm gas pressure in operating conditions
Pb reference (base) pressure
Zm compressibility factor in operating conditions
Zb compressibility factor in reference (base)
conditions

CORUS COMPACT 149


GRAPHIC DISPLAY CONFIGURATION WITH PULSE OUTPUTS
Possiblity to translate messages (Corus Compact)

HAZARDOUS AREA SAFE AREA

CORUS Compact
p

Focus Compact display


Volume
Ex isolator pulse
or alarm
L 20 m
220 V AC
or 24 V DC

Volume
Ex isolator pulse
or alarm
L 20 m
220 V AC
or 24 V DC
Corus Compact display

DIMENSIONS (in mm)


(For both Corus 149
and Focus Compact)
71

119
93

Corus Compact

35
Wall/pipe mounting kit

ACCESSORIES
ª Configuration software
ª Thermowell
ª 3-Way pressure connection kit
ª Optical head
ª Cyble® sensor ATEX module
ª ALIS200 external power supply for
Focus Compact
ª External antenna for Focus Compact

150 GA-Corus-Compact-EN-V2.0-2011.06
FOCUS+
GSM/GPRS Smart Modems
KEY BENEFITS
Designed for a rapidly changing gas industry, ª Greater operational
the Focus+ is a key product of AMR solutions efficiency with remote
for Itron commercial and industrial (C&I) gas data collection
electronic devices. This smart modem provides ª Reduced truck rolls ,
transparent communication between data associated costs and CO2
emissions
collection software tools and devices in the
ª Manage usage and
field, using either GSM or GPRS communication
resources with accurate,
networks. Thanks to an intuitive, user-friendly timely data
interface, the Focus+ is both easy to install and
ª Flexible operation with
easy to operate. Focus+ offers gas network battery, mains or solar
monitoring capabilities with up to four digital powered
inputs that can be used for alarm retransmission ª Proactive operations with
by SMS. The Focus+ platform is available in two meter alarms
variants: Focus+ and Focus+ ATEX; Focus+ ª Simplified installation
ATEX can be installed directly in hazardous through large GSM/GPRS
zone 1 areas. network coverage

C&I GAS APPLICATIONS

FEATURES
ª User-friendly interface for simplified ª Five year battery life with daily
commissioning and handling communication (via GPRS)
ª Can be installed in hazardous areas ª External power supply input
(Focus+ ATEX only)) (Focus+ only)
ª Ultimate communications flexibility ª Alarm notifications delivered by SMS
from quad-band GSM and GPRS ª Compatible with Itron C&I electronic
technologies (for both dynamic and gas devices including Corus, Dattus
fixed IP addresses) and Angus

SPECIFICATIONS knowledge to shape your future 151


DESCRIPTION TECHNICAL FEATURES
Focus+ family of modems includes Approvals
Focus+ and Focus+ ATEX that can be
ª EX-approved, associated device for
used with smart C&I meters (Dattus),
connection to material used in
volume converter (Corus) or SCV
hazardous areas, or as category 1
measurer (ANGus).
device (Focus+ ATEX only) suitable to
Both are GSM/GPRS modem, share a be used in zone 1 hazardous areas
common architecture, common human/ ª CE marking: compliant with 89/336/EC
machine interface and most operational (EMC), 94/9/EC (ATEX) & (RTTE)
features.
The main difference between the two Communication
models is the installation area. ª Quad-band, battery powered GSM/
GPRS modem
Focus+ is approved as associated
device, thus it must be installed in safe ª Outbound GPRS connection (mode A)
area. ª Inbound GPRS connection (mode B)
Focus+ ATEX is approved for installation ª Incoming GSM circuit-switched data
in hazardous area (zone 1), ideal for (CSD) calls
reducing installation costs and risks of ª Remote alarm transmission by SMS
vandalism. ª Automatic bound-in transparent mode
Focus+ ATEX is only battery powered, to the metering device, connected via
thus the GSM modem must be activated an RS232 or RS485 link (RS232 only
for Focus+ ATEX)
for a limited period of the day to transmit
data and achieve maximal energy ª Management of dynamic and private IP
efficiency. addresses (GPRS)
Focus+ can be main or solar powered, Display and Keyboard
which means that the modem can be ª Graphic display
active permanently. ª All data useful for commissioning,
Both Focus+ and Focus+ ATEX are able monitoring of communications status
to use Inbound connection in GPRS and for alarm/events check
modem to predifined IP address in order ª Five button keyboard
to overcome private and dynamic IP ª Messages on LCD can be translated to
addresses provided to modem from any language
usual GSM/GPRS Data subcriptions.
Focus+ family is able to provide gas Digital Inputs
network monitoring with their digital ª Four digital inputs (Two for Focus+ ATEX)
inputs and cantransmit their alarms, but ª Normally-open or normally-closed
also those from Corus volume converter, programmable status
through SMS to a central system or field ª Can be connected to any On/Off signal
technicians cellular phone. type (station door contact, safety valve
position, pressure switch and so on) in
hazardous areas.

Digital Outputs
ª Two digital outputs programmable
either normally open or closed. Status
can be modified remotely. (Focus+ only)

152 FOCUS+
SYSTEM OVERVIEW - FOCUS+
Communication with Focus+ standard installed in safe area
HAZARDOUS AREA SAFE AREA

CORUS FOCUS+

RS-232
R
DATTUS OR
or RS
RS-485 (Option) GSM or GPRS SATURNE or SUPERVISOR+
network Meter Data C
Collection SSoftware
f

ALIS 200

RS-232
RS
OR
ANGUS

Solar panel
or
a s
Mains
R S-48
RS-485

HAZARDOUS AREA SAFE AREA

CORUS FOCUS+

R
RS-485
CORUS
CO US AND
(Option) GSM or GPRS AMR Software
network O
with MODBUS S protocol
Meter Data Collection Software

ALIS 200

RS-485
R
AND
CORUS

R
RS-485
AND Solar panel
CORUS or
Mains
a s

R
RS-485

Up to 4 Corus can be connected to a single Focus+ with RS485 bus and a maximal
distance of 200m between each Corus and Focus+. This solution can be used only if
communication protocol supports device addresses (example Modbus RTU)

FOCUS+ 153
Power Supply Diagnostic Indicators
ª Battery operated or mains or solar The Focus+ or Focus+ ATEX provide
ª Five year average battery life expectancy several counters in order to ease
in GPRS mode for daily communication diagnostic among which:
(three years in GSM mode) ª Provider with best signal in the area
ª End of battery life detection and ª Modem power duration
notification ª GSM communication duration
ª External supply input for mains or solar ª Total amount of data traffic (both
powering with ALIS 200 external power received and transmitted)
supply module (Focus+ only)
Logs
Alarms
The Focus+ or Focus+ ATEX provide
Focus+ or Focus+ ATEX manage several two logs that are used to trace events or
unique alarm types, which can be information during the product lifetime:
transmitted by SMS to designated
ª Events log containing all major events
cellular phone numbers. Alarm start and
occurring during the product lifetime
end states create a new entry in the
are recorded. This log is circular and
events logs. Alarm types include:
can handle up to 200 records.
ª Low battery
ª Parameters log containing all critical
ª External power supply error parameters modifications are traced.
ª Change of digital input status (1 to 2 or 4)
WinLog GPRS Software
ª Modem error
Used for local communications through
ª SIM card error
the Focus+ optical port or a TCP/IP
ª GSM/GPRS network error connection, WinLog GPRS:
Focus+ and Focus+ ATEX are also able
ª Displays real-time (or ”live”) data
to transmit via SMS or inbound calls the
ª Configures general settings for Focus+
alarms of Corus to cellular phone (SMS) or
systems
central supervision system (Supervisor+).
ª Identifies communication flows
(data-scope mode)
ª Displays events and parameter logs
SYSTEM OVERVIEW - FOCUS+ ATEX
Communication with Focus+ ATEX installed in hazardous area
HAZARDOUS AREA SAFE AREA

CORUS FOCUS+ ATEX

RS-
RS-232
DATTUS OR
RS-232
R GSM or GPRS SATURNE or SUPERVISOR+
network Meter Data C
Collection SSoftware
f

RS-232
RS-23

154 FOCUS+
Technical Specifications Focus+
Device Type Quad-band, battery powered GSM/GPRS modem
Approvals and EX-approved device for use in hazardous areas
Certifications 00081 II (1)G [Ex ia] IIA/IIB/IIC LCIE 08 ATEX 6058 X
Compliant with 89/336/EC (EMC), 94/9/EC (ATEX) & (RTTE)
IP 65-rated enclosure
Operating Temperature -20°C to +55°C
Power Supply Internal lithium ion (Li-ion) battery
Five year battery life expectancy (GPRS)
Three year battery life expectancy (GSM)
Keyboard and Display Keyboard with five keys
Graphic display
Inputs and Outputs RS-232 serial port
Four digital inputs (for SMS alarm transmission)
Two digital outputs (status can be modified remotely)
Optical port for local advanced configuration
Internal or external antenna
Dimensions 222 x 145 x 86 mm

Weight 0.93k (without packaging)

Additional Features Input for external power supply through ALIS200, intrinsically safe
supply module
Serial RS485 port selectable instead of RS232

Technical Specifications Focus+ ATEX


Device Type Quad-band, battery powered GSM/GPRS modem
Approvals and EX-approved for zone 1 hazardous areas
Certifications 0123 II 2(1) G Ex ia IIA T3 ZELM 10 ATEX 0450 X
Compliant with 89/336/EC (EMC), 94/9/EC (ATEX) & (RTTE)
IP 65-rated enclosure
Operating Temperature -20°C to +55°C
Power Supply Internal lithium ion (Li-ion) battery
Five year battery life expectancy (GPRS)
Three year battery life expectancy (GSM)
Keyboard and Display Keyboard with five keys
Graphic display
Inputs and Outputs RS-232 serial port
Two digital inputs (for SMS alarm transmission)
Optical port for local advanced configuration
Internal or external antenna
Dimensions 222 x 145 x 86 mm

Weight 0.93k (without packaging)

FOCUS+ 155
GRAPHIC DISPLAY
Possiblity to translate messages
STATUS MODEM ALARM DATA CONFIG STATUS MODEM ALARM DATA CONFIG

GSM status : Ready


Orange F GSM reg : Registered
SIM card : PIN OK
Signal : Good
Local IP : 192.168.0.1
GPRS SERIAL Session Rx : 25 Bytes
Rx Tx Rx Tx
Session Tx : 1025 Bytes

CONFIGURATION WITH PULSE DIMENSIONS


OUTPUTS (For Focus+ and Focus+ ATEX)
(Focus+ only) 222
206
HAZARDOUS AREA SAFE AREA

FOCUS+
42
145
59

Volume pulse
Ex isolator
or alarm
L 20 m
4 holes
220 V AC
Ø 5.2 28 20
or 24 V DC

86
Volume pulse 49
Ex isolator
or alarm
L 20 m
220 V AC
or 24 V DC

ACCESSORIES
ª WinLog configuration software
ª Optical head
ª External antenna kit 25
ª Battery pack
ª External power supply (ALIS 200)
ª Cable Focus+/Corus (1,5,10,20m)

156 GA-FOCUS+-EN-V2.0-2011.06
ISB+
Instrinsic safety box KEY BENEFITS
ª Instrinsic safe interface for
ISB+ is an electronic attachment which ensures RS232 and RS485 ports
a galvanic insulation between hazardous and ª ATEX approved as
safe areas for RS232 and RS485 ports. associated apparatus
RS232 and RS485 ports are available on both ª Din Rail mounting
sides and it is possible to convert a signal from ª Power supply output for
RS232 to RS485 and vica versa. one CORUS

APPLICATION ISB+ must be positioned, in a safe area,


A CORUS, SEVC-D or ANGus can be between both attachments as shown in
read or programmed with a notebook in the diagram overleaf. In addition to
local mode. However the notebook cannot galvanic insulation, the ISB+ ensures the
be directly connected with the RS232 port power supply of the communication port
of Corus or SEVC-D or ANGus, when for the CORUS PTZ, SEVC-D or ANGus.
these devices are installed in hazardous The ISB+ can also provide an external
area. An ISB+ must be used to provide power supply for one CORUS.
the necessary isolation in compatibility When using the RS485 port on the
with ATEX rules. A standard modem, hazardous area side, a multi-drop
RTU or laptop can also be connected connection of several CORUS’ and/or
through the ISB+ to the CORUS, SEVC-D ANGus’ is possible (up to 4 devices).
or ANGus for remote reading. The maximal cable length between the
An external power supply (9-24 VDC) is ISB and the attachments depends on the
used to power the ISB+. The enclosure of characteristics of the cables and the
the ISB+ can be mounted on a DIN Rail number of devices, but it should be
to facilitate integration into a cabinet. limited to 200m.

SPECIFICATIONS knowledge to shape your future 157


DESCRIPTION

Ports: Power input:


ª RS232 and RS485 for hazardous areas ª 9-24V DC 8W min.
(these ports cannot be used at the ª Power output:
same time) ª External power for one CORUS only
ª RS232 and RS485 for safe areas (these
ports cannot be used at the same time) LEDs:
ª RS485 port 2-wire automatic turn-around ª One LED indicating input power
ª Baud-rate 300-9600 presence
ª Power supply for ports RS232 and ª One LED for Tx
RS485 in hazardous areas ª One LED for Rx
ª Multi-drop connections in hazardous
areas possible for RS485 port

Technical Specifications
ATEX Approval Approval N° LCIE 07 ATEX 6083X
II(1)G [Ex ia] II
CCE marking
Environment Operating temperature: - 25°C to + 55°C
IP rate: IP20
Power Supply 9-24V DC 8W
Power Output Only for powering one CORUS
Com Ports RS232 and RS485 ports on both sides (hazardous and safe area)
Baud-rate : 300 – 9600 bauds
Power supply for RS232 or RS485 port in hazardous area
RS485 port: 2 wires auto turn-around
Multi-drop possible for RS485 in hazardous area
Dimensions 140 x 90 x 60 mm (L x l x h)
Maximal Cable RS232: 50m (hazardous and safe area)
Connections RS485: - Safe area: up to 1km
- Hazardous area: (depending on cables) <200m

Power supply output RS232 or RS485 connection


for hazardous area to hazardous area

IIA IIB IIC IIA IIB IIC


Uo 17.3V Uo 7.2V
Io 228mA Io 83mA
Po 986mW Po 480mW
Co 8.5μF 2.06μF 0.353μF Co 1000μF 236μF 10.33μF
Lo 3.6mH 2.4mH 0.6mH Lo 30mH 15mH 5mH

158 ISB+
TYPICAL CONFIGURATIONS

ISB+ CORUS

Power supply
RS232
1 Computer RS232 port
SAFE AREA HAZARDOUS AREA

RTU ISB+ CORUS

RS485
RS485

SAFE AREA HAZARDOUS AREA

Accessories
Power supply module
ª Cables:
• ISB+ /PC (DB9)
• ISB+ /CORUS
• ISB+ /ANGus
• ISB+ /SEVC-D

ISB+ 159
160 GA-ISB-Plus-EN-V2.0-2012.04
Meters & Smart Payment
Modules
Meters GALLUS i V PSC 163
RF1 i V PSC 167
Software 3E - Eclipse Enterprise Edition 171
3E - Field Work Management 175
3E - Replication Suite 179
3E - Reporter 181
3E - Smart Payment 183
3E - Eclipse Vending Gateway 187

161
w w w. i t r o n . c o m

162
GALLUS i V PSC
Leading the Way in Smart Payment Systems

After 18 year of experience in smart KEY BENEFITS


payment, Itron has released the ª Meter Features
second generation of its smart ª Compact size
payment meters. A member of the ª 2 way communication
Eclipse family, the GALLUS i V PSC is ª Long-term accuracy and reliability
the latest Smart Card Smart Payment ª EEC approval and ATEX approval
meter in our Revenue Collection ª Internal valve
Systems. The GALLUS i V PSC with ª Compliant with EN 1359, MID and
an internal valve is considered an OIML standards
ideal entry point into the automatic ª Fire-resistant construction
meter reading world. ª Multiple fraud detection functions

THE SYSTEM The revenue collection module offers


innovative and customer appealing
The GALLUS i V PSC meter features the
functions, such as “no-disconnect” periods,
GALLUS meter, which has been installed
self-decommissioning and emergency
in more than 30 million locations
credit and data logging capability. It also
worldwide.
provides leak and multiple fraud detection;
It has been enhanced with a secure overflow control and broad tariff flexibility.
Payflex Smart Card token. The GALLUS i V PSC is part of the TaleXus
The microprocessor-based Smart Card Vendor™ multi-resource revenue collection
provides low-cost, reliable and secure system. This system provides efficient
two-way communication between the revenue collection, and enhanced data
point of sale (ATM, PC, self-service capture and reporting, for both electricity
POS,…) and the installed meter. and gas utilities.

SPECIFICATIONS knowledge to shape your future 163


FUNCTIONS Safety and Security
Pay-as-you-consume with fraud ª Overflow alarm. The meter is designed
detection to automatically close the gas valve if
There is more and more demand from flow rates exceed 1.2 Qmax. An alarm
the end consumer and utilities to control displayed on the LCD warns the
consumption more accurately. With the consumer that the flow rate is too high.
pay-as-you-consume concept the end ª Leak detection. A leak test is
users need to pay upfront for their conducted every time the gas valve
consumption. The internal valve in the opens to ensure other gas appliances
meter will close down when there is a have not been left on. The valve
fraud attempt or lack of credit. automatically closes if the meter
detects a flow rate of more than 15 l/h.
Data Logging ª The valve closes automatically if a fraud
The GALLUS i V PSC has a built-in data attempt is detected. An alarm is
logging function that can store up the recorded in the meter which will go to
720 index 24 times a day for a 30 day the system. The valve can be reopened
long period. A log keeps track of the last only after the alarm is cleared.
60 events, alarms and actions on the ª Anti reverse flow prevention. When the
meter. meter detects a reverse flow the valve
will close and an alarm will be reported.
No Disconnect
The GALLUS i V PSC can be configured to
avoid disconnection during specified DIMENSIONS (mm)
periods. This can include defined times of
110
day, certain days, weekends, or specific
periods of the year.

Self Decommissioning
The GALLUS meter does not require an
215

on-site visit from the utility to decommission


a consumer account. An automatic
“close down” special action lets the utility
or consumer decommission the account
directly.

188

GALLUS i V PSC
with smart card

171

164 GALLUS i V PSC


Technical Specifications
Metrology Meter conforming to EN 1359 standards over other international
standards
Accuracy Maximum permissible errors (% of measurement)
+/- 3% from Qmin. to 0.1 Qmax. +/- 1.5% from 0.1 Qmax. to Qmax.
Capacity G1.6, G2.5 or G4
Casing Steel
Electronics housing ABS
Dimensions Overall size for 110 mm casing: 215 mm x 188 mm x 171 mm.
Other options available: 130 mm, 152.4 mm (6”) & 160 mm
Weight 2.3kg
Humidity Max 93% RH at 40°C
Operating temperature -10°C to +55°C
Storage temperature -25°C to +70°C
Dust and rain IP54 protection
Maximum operating 0.15 bar
pressure
Pressure drop Under 2 mbar
Drop height 0.5m
Battery Battery 8 years average life time*
Electronics Intrinsic safety EEX ia IIA T3.
Display LCD
Nota: in case of an outdoor installation, only use plastic cabinets (PVC or GRP) and not metal.
* Battery life time may vary depending on usage

RELATED PRODUCTS
Gas Meters: GALLUS (Residential diaphragm gas meter)
Systems: Eclipse 3E (Two-way multi-resource prepayment system)
(Eclipse Enterprise Edition)
TaleXus Vendor™

BATTERY WARNING
ª Fire, explosion and severe burn hazard
ª Do not recharge, short circuit, crush, disassemble, heat above 100°C (212°F),
incinerate, or expose contents to water.
ª Do not solder directly to the cell.
Respect the storage recommendations

GALLUS i V PSC 165


166 GALLUS-i-V-PSC-EN-V4.1-2011.11
RF1 i V PSC
Leading the Way in Smart Payment Systems

Itron has added an innovative Smart Payment KEY BENEFITS


function to its newest generation of widely ª 2 way communication
used RF1 gas meters. A member of the Eclipse ª Compliance with EN 1359,
family of meters, the RF1 i V PSC is the latest MID and OIML standards
Smart Card Smart Payment meter in our ª Multiple fraud detection
Revenue Collection Systems, embodying more functions
than 18 years of Smart Payment and revenue
ª Longterm accuracy &
management experience. safety
ª Worldclass, ISO 9001
THE SYSTEM certified
RF1 i V PSC meter features the RF1 meter, which has ª European Engineering
been installed in more than 8 million locations worldwide. and Manufacturing
It has been enhanced with a Payflex Smart Card token,
which offers a rich selection of flexible applications.
The microprocessor-based Smart Card provides low
cost, reliable and secure two way communication
between the point of sale and the installed meter.
The revenue collection module offers innovative and
customer friendly functions, such as no-disconnect
periods, self-decommissioning and emergency credit.
It also provides leak and fraud detection, overflow
control and broad tariff flexibility.
The RF1 i V PSC is part of the TaleXus Vendor™ multi-
resource revenue collection system.
This system provides efficient revenue capture and
reporting, for both electricity and gas utilities.

SPECIFICATIONS knowledge to shape your future 167


FUNCTIONS ª The valve closes automatically if a
fraud attempt is detected. An alarm is
Pay-as-you-consume with fraud recorded in the meter which will go to
detection the system. The valve can be reopened
There is more and more demand from only after the alarm is cleared.
the end consumer and utilities to control ª Anti-reverse flow prevention. When the
consumption more accurately. With meter detects a reverse flow the valve
the pay-as-you-consume concept the will close and an alarm will be reported.
end users need to pay up front for their
consumption. The internal valve in the
meter will close down when there is a
fraud attempt or lack of credit.

Data Logging
Technical Specifications
The RF1 i V PSC has a built-in data logging Metrology Meter conforming to
function that can store up the 720 index EN 1359 standards
24 times a day for a 30 day long period. over other international
A log keeps track of the last 60 events, standards
alarms and actions on the meter. Accuracy Maximum
permissible errors
No Disconnect (% of measurement)
The RF1 i V PSC can be configured to avoid +/- 3% from Qmin. to
disconnection during specified periods. 0.1 Qmax. +/- 1.5%
from 0.1 Qmax. to
This can include defined times of day,
Qmax.
certain days, weekends, or specific
periods of the year. Capacity G4 or G6
Casing Steel
Self Decommissioning Electronics housing ABS
The RF1 meter does not require an on-site Humidity Max 93% RH at 40°C
visit from the utility to decommission a
consumer account. An automatic “close Operating -10°C to +55°C
temperature
down” special action lets the utility or
consumer decommission the account Storage temperature -25°C to +70°C
directly. Dust and rain IP54 protection
Maximum operating 0.5 bar
Safety and Security
pressure
ª Overflow alarm. The meter is designed
Protocols
to automatically close the gas valve if Payflex Smart Card
prepayment
the flow rate exceeds the overflow limit.
Battery Battery 8 years
An alarm displayed on the LCD warns the
average life time*
consumer that the flow rate is too high.
Electronics Intrinsic safety
ª Leak detection. A leak test is conducted
EEX ia IIA T3
every time the gas valve opens to
ensure other gas appliances have not Display LCD
been left on. The valve automatically Nota: in case of an outdoor installation, only use
closes if the meter detects a flow rate of plastic cabinets (PVC or GRP) and not metal.
more than 15 l/h. * Battery life time may vary depending on usage

168 RF1 i V PSC


Dimensions (mm)
Two pipe One pipe
Connection
DN 20 25 -
A (spacing) mm 220 - 250 210 - 250 -
B mm 274 267 280
C mm 209 209 202
D mm 325 325 233
E mm 71 71 70.7
Weight kg 3.2 3.2 2.9

DN C
A DN C E
E

B
B

D D

RELATED PRODUCTS
ª Meters
• RF1
(Residential diaphragm meter)
ª Systems
• Eclipse 3E “Eclipse Enterprise Edition”
(Two-way multi-resource prepayment
system)
• TaleXus Vendor™

RF1 i V PSC with smart card

BATTERY WARNING
ª Fire, explosion and severe burn hazard
ª Do not recharge, short circuit, crush,
disassemble, heat above 100°C (212°F),
incinerate, or expose contents
to water.
ª Do not solder directly to the cell.
Respect the storage recommendations
RF1 i V PSC One Pipe

RF1 i V PSC 169


170 GA-RF1-i-V-PSC-EN-V3.0-2011.08
3E
Eclipse Enterprise Edition
Smart Payment Software for Gas

More than 3 million customers worldwide are KEY BENEFITS


using Itron smart payment systems and with ª Convenient Vending
more than 18 years experience, Itron provides ª Pay as you go &
quality meters, builds and supports the systems Prepayment
and provides hosting services for Utilities. ª Multi-channel vending
ª STS & Smart Card
Utilities are turning more and more to smart payment ª Enhances revenue
systems for enhanced revenue management and ª Reduces fraud
customer service. Such systems have become a key ª Provides management
element in the new strategies utilities are defining to & customer services
move forward in ever-more deregulated environments. (automatic readings,
For the end customers, they now have the possibility multi-tariff possibilities...)
to control their consumption and access value added
ª Optimises gas network
services, while the utility optimises its revenues.
against bottled gas
Itron has developed the Eclipse Enterprise Edition to
ª End user controls
fit these needs.
consumption & debt

SPECIFICATIONS knowledge to shape your future 171


The Itron Eclipse Enterprise Edition (3E) Eclipse Enterprise Edition is scaleable
supports both smart cards and Standard from 300 up to 5 million meters and
Transfer Specification (STS) token supports two different ways to handle
transactions, and is the only system end-user payment:
existing today that can do both. ª Prepayment; the end-user has to pay
Our system uses the STS open standard up front for gas consumption,
for smart payment and for far reaching ª Pay as you go (soft prepayment);
multi-channel vending networks such as: the end-user consumes gas as with a
regular credit meter but after a certain
➊ Mobile telephone (via SMS) vending
time or volume used is forced to pay
At home through an Internet site otherwise the meter will close down.
➋ Scratch cards that can be bought in
Multi-language, the system will help to
any shop
collect meter reading data, outstanding
➌ Cash or bank card based self-service debts or different charges with unlimited
kiosks or vending stations tariff possibilities. Tariffs can be updated
➍ Mobile points of sales / bookshelf on a daily basis making it very flexible
point of sales for shops for utilities to manage. Its data logging
➎ Interface with a “third party” vending capabilities enable utilities to detect and
network such as banks, post offices, minimize tampering and fraud on the
petrol stations, shops meter side and on the system side smart
tools are used to analyse consumption
These different channels provide utilities profiles.
with the best choice for their end-user
making payments as easy as possible for
their customers.


172 3E - Eclipse Enterprise Edition


ACE ECLIPSE REVENUE ECLIPSE EXTENDED VENDING
COLLECTOR GATEWAY (EVG)
The ACE Eclipse Revenue Collector The Eclipse Extended Vending Gateway
system, part of the Eclipse Enterprise (EVG) is an independently managed
Edition, is a true online vending, customer, transaction platform, that allows for the
meter and location management system. activation of a multitude of vending and
The full Service Oriented Architecture distribution channels.The gateway is built
provides a graphical user interface through on platform independent technology
a standard web browser, over a host of and optimised for high volume vending,
communication channels. merchant management, administration
Benefits of complex commission structures and
banking standard security.
ª STS keypad and magnetic compliant
system, preventing supplier lock-in The Eclipse EVG is an integrated solution
ª Comprehensive meter, revenue, that allows it to be plugged into the
customer and system management Eclipse Vending System. This allows for
software, ensuring data integrity the expansion of vending and distribution
channels of the vending system.
ª Credit vending over existing channels
(eg cellular phone, Internet or via GPRS), Eclipse EVG is already integrated with
providing reduced/ manageable various other payment platforms and
software footprint brings a true transaction switch to the
overall payment architecture.
ª Powerful, flexible tariff engine manages
complex tariff structures, fixed charges Benefits
and debt collection at point of sale
ª Platform independent
ª Run-time customisable token templates
ª High volume transaction switching
enable endless changes to information
printed on tokens ª Web-based administration
ª Merchant management - credit,
Features
commission
ª Online customer, location and meter
ª Can easily be integrated with other
administration interface, using web
systems
browser
ª Run on Oracle database Features
ª Fully scaleable and flexible architecture, ª Terminal and PC-based Point of Sale
capable of high transaction volumes (PoS)
ª Real time Online vending and adminis- ª Voucher redemption and management
tration via GPRS (or any TCP/IP carrier) ª Cell phone vending - merchant &
ª Optimal reliability, security and data consumer
integrity ª Consumer web site for vending
ª EFT (Electronic funds transfer)
ª Bill payments
ª Airtime sales for prepaid cell phones
ª Custom integration with other services
and payment gateways

3E - Eclipse Enterprise Edition 173


Smart payment Smart payment point of sales network Smart payment
meters system

WWW site Mobile POS


Backup system
Data
replication

Fuel stations
Shops, Banks...

Third party vending


SMS vending network
Primary system
Web interface

Web interface
EFT/ Gateway
payments
Self service kios
ters
nt Me
Payme
r Smart Gas
Vouche Scratch Card

75 E
Patefacto consilio meo, nihil primo virgo
pervenissemus, silentium tandem

Voucher
or scratch card
Helpdesk Payment server

STS transaction
Smart card transaction Point of sales comm.

174 GA-3E-SmartPay-EN-V2.0-2011.12
3E
Field Work Management
With Frontline

The effective management of field work is a key element to ensure


control over metering assets. Past experience has shown that one
of the critical breakdown points of a works order management
system is the integrity of the field data. A paper-based system does
not allow validation of a field record at the metering point, where
the record is actually updated. Data capturing errors needs to be
corrected through a costly revisit.
Frontline was born through the field experienced gained by Itron
in many turnkey meter installation/ replacements and revenue
protection projects. It combines the advantages of a works order
management system with an electronic paperless solution for the
capturing and processing of all field data.

THE BIGGER PICTURE Management is all about information, being


Revenue Protection is just about that in the know. What better way to manage
- Revenue. In Prepayment Systems, field assets, than having all the information
revenue rests in the vending system. you need available at a mouse click, literally
What good is a vending system, if the minutes after it happened in the field.
difference between the database and the Targeted revenue protection inspections
actual installed base, is as similar as are continuously performed to ensure
theory and practice? tampering and fraud is minimized.
ACE Frontline, integrated to the Itron It is not about the GPS device, It’s about
Eclipse Vending system, changes the the whole process (Controls, efficiency,
vending database, as the installed base practicality, The back-end & field systems,
changes, while it’s happening. What eg Software, IT H/W, People, owners of
better way to ensure these is in sync? specific data set, etc).

SPECIFICATIONS knowledge to shape your future 175


Meter Management Functions: All completed fieldwork is automatically
ª Installations ª Audits updated to the system when the Hand
ª Replacements ª Recording Held is synchronized to the back end
Frontline system. (At the desk or via
ª Disconnections location data
GPRS synchronization)
ª Reconnections
When Ace Mobile is deployed on a Hand
ª Inspections Held Unit with GPRS communication
Basic Architecture capability, the data synchronization may
be initiated directly from the field. This
Frontline is a web-based application that
reduces office administration and turn-
allows the user the flexibility to connect to
around to a minimum.
the back end system from any machine
on the network. Reporting views (or “cubes”) are cross-
functional – from purchase patterns
The user interface allows for different user
reports, to meter management reports
profiles with varying levels of functional
and is tailored to requirements
access. The operational manager uses
the web-based administration interface Spatial Analysis
to coordinate the following daily tasks: Management Reports
ª Add and configure new system users Inspection Reports
ª Register a mobile Hand Held Unit on Intelligent Archiving
the system Ability to manage internal resources
ª Assign a Hand Held Unit to a field and contractors uniformly across all
operator operational areas - simply
ª Get Work Orders from a central system It is immediate availability of information
ª Assign Works orders to a field operator for decision making.
ª Check meters from a storeroom to a Accurate performance reporting
contractor (operational, financial and technical)
ª Synchronize Works orders between Establish Benchmark for future revenue
the Hand Held Unit and the Frontline improvement measurement - investment
system justification
ª Synchronize records between Frontline Build sustainable energy balancing
and a central system model – measuring actual consumption
The second element of the Frontline (sales) vs supply
solution is a user application designed Improve existing field operation processes
around the requirements of the field
Increase revenue collection and
technician. Ace Mobile runs on a rugged
consequent reduction in consumption at
Hand Held Unit (HHU).
the bulk account level.
The software will guide the field operator
through a specific task with a wizard Meter Installation
driven interface. Automatic validation Management Problems experienced in
checks ensure the highest level of data managing field installations are often as a
integrity. The Hand Held is also equipped result of the manual documentation errors
with a bar code scanner. involved with a paper based system.
This prevents any mistakes with entering Frontline was developed to improve the
a meter serial number manually. turnaround time (and the quality) for the

176 3E - Field Work Management


DATA MOVEMENT

External System interface Field Tool


(DB Schema)

External Data METER


Source Option MSNO MSNO LOCATION
LOCATION

Storeroom
3rd Party systems Management Module

Database
Frontline
Frontline
Web
ACE HHU
CSV or
Mobile Toolbox
CONSUMER
Txt File

File creation OUT

WORK ORDER
IN

3E Database Create LOCATION


Work Order MSNO
WORK ORDER
Module Work Order Status Change
Location Change

Manual Creation = Meter Serial Number


MSNO

management of the data associated with FUNCTIONALITY


meter installations, replacements and ACE Frontline provides the field engineer
inspections. or technician with a live link to the meter
The Frontline software is designed to be management database. In the same
able to create a works order directly from fashion and as important, it provides
the central 3E database; or alternatively to Management with a live link to the field.
also accept a works order from an From the Office to the Field, meter
independent third party system. management functions are defined,
The detail of the metering point, as forming the guideline for field activities. In
described by the works order, is return, from the Field to the Office, field
downloaded to the Hand Held. data is collected and sent to the relevant
The field operator will use these details to management systems. While ACE
confirm the location (and the old meter Frontline runs it’s own database, the
details for a replacement) before he interface is a secure web interface. This
proceeds with the work. implies frontline can run on the same PC
as Eclipse, but even better - a manager
All new data attributes and findings
can log in from his desk.
resulting from the fieldwork are updated
to the works order. The work order status The factors fuelling problems of
will change to “completed” only after all managing field installations are often a
compulsory fields have been entered and result of the manual documentation
validated by the system. processes involved. The live interface
from ACE Frontline ensures records are
It is also possible to capture a GPS
delivered and updated, every time,
coordinate with the HHU’s own integral
anytime, from anywhere, everywhere.
GPS receiver. This ensures the highest
level of operational control.

3E - Field Work Management 177


SECURITY
Integral, but also core to, successful one way prepayment is the element of security.
With the built-in GPRS functionality of the ACE Frontline Handheld Unit, this component
in the open environment needs to carry no additional security measures. The available
functionality of the Handheld Units, user administration, in fact the entire system, is
controlled from the office - the secure environment. Just another way in control never
leaves the domain of the manager.

FIELD PROCESSES:
Electronic Meter Installation
IN THE FIELD REGIONAL OFFICE
Submit
Electronica
Electronically

ble to All Use


aila rs
Av
INSTALL METER
Less than

MANAGE METERS
1 Day
Cycle

TSP -
I P C l oud

VENDING CHANNELS CENTRAL OFFICE

Workflow type:
ª Install a Meter (no Point of Distribution exists)
ª Replace a Meter (Meter conversions)
ª Meter Replacement (Primary and Secondary scan)
ª Disconnection: Meter off and valve closed (doesn’t mean remove the meter.)
ª Reconnection: Meter open up and valve opened.
ª Inspection: Maintenance and repair meter (index reading, alarm, issue etc or regular
checking per month)

178 GA-3E-Field-Work-Management-EN-V2.0-2011.12
3E
Replication Suite
DB visit

3E Replication Suite is a completely hands-off, fully automated


replication and standby database software solution.
3E Replication Suite automates the synchronization of the standby
database at a remote location for disaster recovery purposes and
for other advanced database operations.

Disaster Recovery (DR) is vital, without SUMMARY OF KEY FEATURES:


it your business could shut down. Also ª 3E Replication Suite works with
more and more companies are required Microsoft Windows, UNIX, and Linux.
to comply with industry regulations in
ª Supports Oracle versions 8i to 11g,
terms of security and data accountability.
both 32-bit and 64-bit (may support
3E Replication Suite managed Oracle
Oracle 7.3 and 8.0 in some cases).
standby databases achieves full disaster
recovery capability as the standby ª Supports Oracle flash recovery area,
database is ready to take over should OMF and ASM file systems.
your primary site suffer a disaster and no ª Failover to standby database (to use
longer be available. standby instead of primary).
3E Replication Suite also maximizes return ª Time-delayed updating of standby
on standby hardware investment as database, enabling recovery of data loss
processing loads can be offset from the due to human error or software error.
primary database to the standby database. ª Automatic continuation without
For example, your standby database can intervention of the DBA when temporary
be used to run large reports or backups network or database problems occur.
which would otherwise impact your ª Automatic notification included.
primary database. Notification thresholds can be set.

SPECIFICATIONS knowledge to shape your future 179


ª Fully automated management and
monitoring of the Oracle archive logs
on both the primary and standby
server.
ª 3E Replication Suite produces
comprehensive trace files which can be
Dbvisit keeps
analyzed by 3E Replication Suite support standbydatabase
up to date
for fast turnaround time on any issue.
ª 3E Replication Suite is a cost-effective Dbvisit transfer
enterprise class Oracle standby all updates to
standby database
database solution.

STANDBY DATABASE OVERVIEW:


ª Exact copy of main database in a
remote location.
ª Is held up to date by applying changes Users can
continue
from main database. operation
on standby
ª In the event of a disaster, standby database
database becomes active.
ª Users are transferred to standby
database to continue operation.
Main Database
is no longer
available due
to disaster

180 GA-3E-Replication-EN-V2.0-2011.12
3E Reporter
Crystal reporter

Eclipse Reporter is a business intelligence application used to


design and generate reports from a wide range of data sources.

REPORT DESIGNER Both fields and formulae have a wide


Eclipse Reporter allows users to array of formatting options available,
graphically design data connections and which can be applied absolutely or
report layout. In the Database Expert, conditionally. The data can be grouped
users can select and link tables from a into bands, each of which can be split
wide variety of data sources, including further and conditionally suppressed as
Microsoft Excel spreadsheets, Oracle needed. Eclipse Reporter also supports
databases, Business Objects Enterprise sub reports, graphing, and a limited
business views, and local file system amount of GIS functionality.
information. Fields from these tables
can be placed on the report design
surface, and can also be used in custom
formulas, using either BASIC or Crystal’s
own syntax, which is then placed on
the design surface. Formulas can be
evaluated at several phases during
report generation as specified by the
developer.

SPECIFICATIONS knowledge to shape your future 181


REPORT OVERVIEW
ª Customer Report ª Revenue Report
• Open Customer details • 12 month Revenue History Overview
• Open meter details • 6 month Revenue History Overview
• Open Meter purchase pattern • Country Sales summary
• Customer debt report • Vendor Sales summary
• Broken contract active report • Tariff Sales summary
ª Meter Report • Manage Sales summary
• Meter Alarm codes report • Sales per account report
• Meter reading report ª Revenue Protection Reports
• Meter close down report • Zero_low purchase profile report
• Installed meter report
• Special action repliers report

SUPPORTED DATA SOURCES

D
Database
D
Diagram

INTERFACE

182 GA-3E-Reporter-EN-V2.0-2011.12
3E Smart Payment
Multiple Vending Channels

PC point of sales Self service point of sales


(Eclipse Revenue Manager) (Kiosk)
KEY BENEFITS KEY BENEFITS
ª Web based POS ª 24/7 open vending point
ª Customer service offices and or banks ª Touch screen self-service POS
offices to be selected for VENDOR ª Accepts bills and coins
ª Internet connection required ª Loads/ charge smart card
ª No installation of client software ª 17” LCD Monitor
ª Easy configuration with Eclipse ª Can be installed in protected areas
Revenue Manager application
ª Search function for all existing Flexible KIOSK design
customer agreements The kiosks are standalone, walk-up,
ª All transaction history storage multimedia kiosks that also provide a
light box for advertising or signage.
ª Customer reversal and system reversal
functions With its sleek, streamlined design and
ª Easy edition for receipt durable construction, it is the ideal choice
for almost any kiosk application.
ª XML file configuration
The attractive curved face and trim
ª Transaction logs file back up
options can be customized to fit any
environment.
The Kiosk can be configured in many
ways to maximize the value of your
marketing and corporate image.
This kiosk can be branded with your
corporation’s color scheme, logo or
advertising materials for the greatest
impact.

SPECIFICATIONS knowledge to shape your future 183


The self service kiosk is available in a the Vending Interface Specification.
variety of finishes -metal, bright colors or With the kiosk software the Gas or
wood trim - the kiosk will blend right into Electricity smart cards can be charged.
your location’s decor. The screens on the kiosk are
This kiosk software is working with Itron’s customizable on the utility request.
smart payment system: 3E system The self-service kiosk has an Ethernet
The kiosk is communicating with the 3E card build in (GPRS optional)
vending gateway and is compatible with

Technical Specifications Kiosk


Dimensions Without overhead signage or display: 1530(H) x 570(W) x 510(D)mm
With 17” LCD overhead display or signage: 1980(H) x 570(W) x 510(D)mm
Specifications Durable steel enclosure
Optional overhead signage area
Pentium Dual Core CPU
Dual Amplified Speakers
Optional peripherals 17” LCD with touch screen
Laser Printer
8.5” thermal printer
Smart card reader
Ticket Printer
Coin acceptor for Euro’s
Euro bill Acceptor

Itron Kiosk Component Kit items K


Kiosk
ª 17” LCD: standalone indoor enclosure
designed for 17” LCD, all metal
construction w/Powdercoat finish,
Thin metal sides, Lock-n-key entry,
ADA compliant, Front and rear service
doors, fans as required. Includes the
following components.
ª Internal coin hopper enclosure and
box, 2nd box for swap out
ª Service keyboard Std PC Keyboard ª SCR Chip Card reader (mounted on
and mouse door fast swap out inti USB hub)
ª KIOSK Amplified Dual Speaker System ª 17” LCD Monitor
driven from PC
ª 17” Resistive touch screen overlay
ª Custom Thermal receipt Printer w/ USB interface
PCVKP80II-UE 80mm paper widths,
ª Dell GX760 Pentium Dual Core E2220,
USB or RS 232 interface, Includes
2.0GHz, 512MB RAM, 80GHD,
ª Power supply, paper guide, and paper integrated NIC card 10/100/1000, 24X
spindle. DVD/CD-ROM, 1 Parallel port, 1 Serial
ª Coin Acceptor EMP 890 Mini faceplate port, 8 USB ports, 1 Ethernet port, 1
ª Bill Acceptor - Hemisphere West Matrix PCI expansion slot for upgraded video
600 Bill Stacker USB interface and Win XP Pro OS

184 3E - SMART PAYMENT


Mobile point of sales (POS) Mobile POS Device
ª Superior customer acceptance:
KEY BENEFITS
revolutionary ergonomics make the
ª Convenient for vendor terminal feel right, with its compact
ª Low cost shape, integrated privacy shield, easy-
ª Provides only vending interface to-use keypad and prominent display.
ª Provision for value add services ª Total transaction security: the terminal
Functions: design provides physical security,
backed up by a dedicated security
ª Reading card
processor, SSL-encryption, and
ª Vending
international and local certifications,
ª Receipt/ticket printing such as PCI PED and EMV.
ª Reversals and reprint
ª User based security and login

Introduction
The Mobile POS terminal allows vending
on very small and mobile POS (point of
sales). The goal of this is to offer a reduced
and flexible solution for connection with
3E (Eclipse Enterprise Edition) through
EVG (Eclipse Vending Gateway).
The Mobile POS makes smart cards
charging very easy with a simple Internet
connection (wired or wireless). This
prevents having infrastructures such as
offices, computers, printers etc Mobile POS

Technical Specifications Mobile POS


Keypad Backlit ergonomic keypad
Display 128 x 64 pixel backlit graphic displays
Card reader Chip- card (EMV 4.0 level 1 compliant)
Triple- track magnetic-stripe reader (ISO ½/3)
Communications Standard: Ethernet interface and dial-up modem
Optional communication interfaces:
- ISDN
- GSM/GPRS
- WiFi
Physical Dimensions: 132 x 132 x 132 mm (l x w x h) - Weight: 740 g
Power Power supply via adapter: 100- 250 VAC, 47-63 Hz
Powered USB cable (option)

3E - SMART PAYMENT 185


186 GA-Smart-Payment-Multiple-Vending-Channels-EN-V2.0-2011.12
3E
Eclipse Vending Gateway
Diversified vending and payment channels

The key to successful smart payment, is the availability of


convenient vending points. As a common philosophy in the retail
world, retailers are required to adapt to customers’ needs.

The practical implication of gas vending The EVG system is the perfect tool for
means customers must be able to buy managing these. Not only for the
gas anywhere, everywhere, anytime and management efficiencies, but also for
every time. Consumers restricted to buying automated functionality, such as discount
only during office hours or having to queue and commission structures policies
for long periods of time, are in time bound configurable per vendor.
to find creative ways of obtaining gas. In addition, the core module of EVG
Eclipse Extended Vending Gateway, or utilizes an open interface specification,
EVG, provides our customers with the providing for seamless and effortless
means of putting a vending station in any integration to external vending systems.
location in a matter of seconds whilst
keeping central control. Electronic Fund Transfers
Engineered on the ISO 8583 banking
FUNCTIONALITY protocol, EVG is a certifiable banking
The major functions catered for by switch and by integrating to a bank, it can
Eclipse Vending Gateway software are handle purchasing of gas via the internet
Retailer Management, SuperVending or mobile phone. Unrivalled convenience,
Capability, Switching Services and no cash charges, no cash management
Vending Channel provisioning: and no risk makes this a valuable solution.

Supervending Capabilities Vending Channel Provisioning


For 24/7 vending convenience, most EVG offers a variety of vending channels
utilities are forced to use third party or to cater for vending convenience and
external retailers for vending gas. flexibility.

SPECIFICATIONS knowledge to shape your future 187


PC Point of Sale COMMUNICATION TECHNOLOGIES
It is possible to vend making use of a Most EVG vending channels employ
PC Point of Sale. This PC can make use online vending. Knowing that
of Windows or Linux as operating system communication infrastructure can hamper
with the Vending Client installed. the implementation of online vending,
The vending client allows the Vendor to Itron has incorporated redundancy into
not only vend gas tokens, but also to add, the communication channels, rather than
delete or disable and/or rename users taking a step back and using offline
and passwords. systems. EVG therefore employs
communication over any TCP/IP layer.
Mobile Point of Sale Communication modes currently in use are:
Mobile Point of Sale or MPOS is the ª GPRS
vending terminal of choice for retailers,
ª GSM
preferred for flexibility, low counter
space usage, and reliability. The devices ª WiMAX
cater for a number of communication ª LAN/WAN
mediums; namely, GPRS, GSM, WiMAX, ª Telephone Dial-Up
LAN/WAN.
HARDWARE REQUIREMENTS
WEB INTERFACE It is recognized that many customers
This channel enables consumers to have particular PoS hardware
purchase gas over the public internet, requirements and has therefore released
using secure credit card payment vending software for a number of PoS
methods. This option also allows a user terminals, including:
to register on the website to purchase ª Spectra Creon, 2008 model or newer
gas using a mobile phone short text ª Banksys/Atos Xenta & Xentissimo
message (SMS), stating only the amount ª Any PC using Windows or Linux as
needed and password. operating system
The EVG system assists in community
development as it promotes the STANDARDS
establishment of small businesses where The system is STS compliant and
commodity items such as prepaid gas complies with the open standard as
and mobile phone airtime can be sold described in the latest NRS2.1 XML-Vend
through various channels. specification.

188 GA-Eclipse-EVG-EN-V2.0-2011.12
Gas Regulator
Technology

189
Overview

w w w. i t r o n . c o m

190
Regulators
Itron Gas Pressure

Itron has over 100 years of proven experience in the manufacture and
use of gas pressure regulators and associated safety devices.
Our Total Quality policy ensures that today’s technically advanced
product range comply with the highest national and international
standards, to meet the exact needs of different systems throughout
the world.

Our gas pressure regulators are An extensive range of regulators is


designed for accurate, dependable and manufactured to US standards in Owenton,
safe use with most non-corrosive gases Kentucky. This line is designed with a
including air, nitrogen, dry carbon dioxide building block approach, utilising common
and propane, in natural gas distribution components and parts throughout the
systems and industrial applications such product range. The result is an extremely
as burners and boilers. versatile and innovative product range
that offers an economical solution to the
most challenging regulator applications.
The European product line, manufactured
in Karlsruhe, Germany covers most
applications in natural gas distribution,
from high pressure regulators used in city
gate stations to residential regulators.
These regulators and safety devices offer
a wide range of combinations, including
integral safety shut-off valves and built-in
creep relief valves.

SPECIFICATIONS knowledge to shape your future 191


Gas Regulation Overview
PRODUCT LINE SERus HR91 WMR SER11 133 233

pu max2 pd max3
25 bar 13 bar
19 bar 2.5 bar
19 bar 4.8 bar
16 bar 1.1 bar
10 bar 350 mbar
10 bar 750 mbar
10 bar 135 mbar
8 bar 700 mbar 300 Sm3/h
8 bar 420 mbar 50 Sm3/h
5 bar 50 mbar 25 Sm3/h
400 mbar 35 mbar 12 Sm3/h
100 (200) 50 mbar 100 Sm3/h
mbar
100 (200) 30 mbar 25 Sm3/h
mbar
pu max2 = max. inlet pressure pd max3 = max. outlet pressure

PRODUCT LINE SERus HR91 WMR SER11 133 233


Outlet pressure range 20-30 mbar 18-50 mbar 15-35 mbar 20-50 mbar 9-420 mbar 8-700 mbar

Size DN 20 DN 25 3/4” DN 25 3/4” 11/2”


DN 25 DN 32 G 11/2” 1” DN 40
DN 32 DN 40 DN 25 DN 50
DN 40 DN 50 G 11/2”
mono-pipe

Connection threaded threaded threaded threaded threaded threaded


flanged flanged flanged

Possible added safety safety safety safety diaphragm safety diaphragm safety diaphragm
components diaphragm diaphragm diaphragm gas loss gas loss protection OPSO
protection OPSO UPSO
gas loss gas loss gas loss OPSO UPSO SRV
protection protection protection SRV SRV

Typical capacities in the field, for special sizing please use our documentation

192 REGULATORS
RB 1200 RB 2000 RB 3200 RR 16 RB 1700-1800 RB 4000 RB 4700

8000 Sm3/h
3
4000 Sm /h
800 Sm3/h
3500 Sm3/h
150 Sm3/h
65 Sm3/h
25 Sm3/h

RB 1200 RB 2000 RB 3200 RR 16 RB 1700-1800 RB 4000 RB 4700


13-135 mbar 5-750 mbar 7-350 mbar 10 mbar-1.1 bar 19 mbar-4.8 bar 10 mbar-2.5 bar 10 mbar-13 bar

DN 20 1”x1” 1”x11/2” DN 25 3/4” DN 25 DN 25


1”x 11/2” DN50 1” DN 40 DN 40
DN 80 1 1/2” DN 50 DN 50
DN 40 DN 80 DN 80
DN 50 DN 100 DN 100

threaded threaded threaded flanged threaded flanged flanged


OPSO flanged

OPSO OPSO OPSO OPSO OPSO OPSO OPSO


UPSO OPSO SRV OPSU OPSU OPSU OPSU
SRV SRV SRV (RB 1800)

REGULATORS 193
Itron Karlsruhe Manufacturing Site, Germany

Full details and product brochures on our Regulator range can be found at www.itron.com

194 Regulators
Meter Data
Management

195
w w w. i t r o n . c o m

196
IEE
Itron Enterprise Edition
FEATURES & BENEFITS
Today’s large utility can be a patchwork quilt of collection and analysis technologies.
Utilities collect customer data using are available to meet your business and
multiple systems that vary depending on technology needs: Microsoft SQL Server
the type of customer and the type of or Oracle. The choice is yours. Using one
technology that was available and secure, centralized data management
affordable at the time of deployment. environment significantly reduces the
Itron Enterprise Edition (IEE) Meter Data likelihood of errors in business processes
Management seamlessly combines meter that use meter data. Because IEE easily
data from multiple collection systems into a interfaces to existing billing systems and
single data repository through its ability to analysis tools, you can deploy a cost-
interface with a wide array of applications effective data management system
and systems. Two database platforms without affecting existing billing processes.

Readings
Handheld Configuration
Events Billing (CIS)
Calculation
Mobile
Data Analysis
Itron
Advanced Meter Reading Enterprise
Edition Outage Management
MV-90

Knowledge Applications
3rd-Party Collection Systems

Itron Enterprise Edition’s central role in data management gives your company unrivaled security and flexibility

SPECIFICATIONS knowledge to shape your future 197


198 IEE - Itron Entreprise Edition

Potrebbero piacerti anche