Sei sulla pagina 1di 19

UNIVERSIDAD NACIONAL MAYOR DE SAN

MARCOS
Facultad de Química e Ingeniería Química
E.A.P. INGENIERÍA QUÍMICA

Departamento Académico de Operaciones Unitarias


Laboratorio de Ingeniería Química II
DETERMINACION EXPERIMENTAL DEL COEFICIENTE
DE DIFUSION N-PENTANO-AIRE

DOCENTE:

Ing. Gloria Contreras

INTEGRANTES:

 Calle Carrión, Luis


 Ormeño Ramirez, Edgar
 Orozco Vasquez, Maycol
 Vilcarromero Chocaca, Keily
TABLA DE CONTENIDO

I. RESUMEN ...................................................................................................................................................1
II. INTRODUCCIÓN........................................................................................................................................2
III. PRINCIPIOS TEÓRICOS ........................................................................................................................3
3.1. Difusividad másica en fase gaseosa..................................................................................................... 3
3.2. Método de Winkelmann ...................................................................................................................... 4
IV. DESARROLLO EXPERIMENTAL ........................................................................................................5
V. TABLA DE DATOS EXPERIMENTALES ................................................................................................6
VI. TABLA DE RESULTADOS ...................................................................................................................7
VII. DISCUSIÓN DE RESULTADOS ...........................................................................................................9
VIII. CONCLUSIONES..................................................................................................................................10
IX. RECOMENDACIONES ........................................................................................................................10
X. BIBLIOGRAFÍA ........................................................................................................................................10
XI. ANEXOS ................................................................................................................................................11
11.1. Ejemplo de cálculos ....................................................................................................................... 11
11.2. Gráficas.......................................................................................................................................... 14
11.3. Tablas de Propiedades ................................................................................................................... 15
ÍNDICE DE TABLAS
Tabla V-1 Datos experimentales de longitud de n-pentano, L, mm, en el tubo delgado de vidrio en función del
tiempo, t en ks, y las temperaturas correspondientes ...........................................................................................6

Tabla VI-1 Datos calculados para el cálculo de la difusividad del n-pentano en aire a 27ºC y 760 mmHg ........7

Tabla VI-2 Condiciones de operación y Propiedades de la n-pentano ................................................................8

Tabla VI-3 Concentraciones de los fluidos y coeficiente del n-pentano en aire calculado por el método de
Winklemann's ...................................................................................................................................................... 8

Tabla VI-4 Potenciales de Lennard Jones Jones y volúmenes molares de difusión para el cálculo de la
difusividad del n-pentano en aire utilizando las correlaciones Chapman-Enskog, Wilke-Lee y Fuller-
Schettler-Gidding ................................................................................................................................................ 9

Tabla VI-5 Comparación del coeficiente de difusión experimental del n-pentano en aire a 27º C y 756mmHg
con tres correlaciones y otro valor obtenido experimentalemente por el método Stefan. ................................... 9

Tabla XI-1 Potenciales de Lennard-Jones para el aire y n-pentano (Poling, Praustniz, & O'Connell, 2001) ....15

Tabla XI-2 Volúmenes de difusión atómica (Poling, Praustniz, & O'Connell, 2001)........................................16

Tabla XI-3 Coeficientes de difusión de n-pentano en aire .................................................................................16

ÍNDICE DE FIGURAS

Figura IV-1 Diagrama experimental ....................................................................................................................5

Figura XI-1 Curva para la determinación del coeficiente de difusión de vapor n-pentano en aire ....................14

Figura XI-2 Parte lineal de las curvas t/(L-Lo) vs (L-Lo) para la determinación de las pendientes, para las tres
corridas ...............................................................................................................................................................14
I. RESUMEN

En el presente trabajo se utiliza el método Winklemann para determinar el coeficiente de difusión del n
pentano por evaporación de su superficie líquida en el aire a 27ºC y 756 mmHg empleando un equipo de
difusión gaseosa CERa-Armfield. Para ello se realiza dos corridas, cada una con diferente personal. Se
registró datos de longitud del n-pentano en el tubo de vidrio, L, con la ayuda de un vernier; en función del
tiempo, t.

El promedio de los coeficientes de difusión calculados experimentalmente de las dos corridas es 0,0912
cm2/s el cual se comparó con los valores calculados de tres correlaciones, Chapman-Enskog, Wilke-Lee,
Fuller-Schettler-Gidding y una obtenida de la literatura (método Stefan) siendo estos valores 0,0855
cm2/s, 0,0925 cm2/s, 0,0861 cm2/s y 0,0900 cm2/s respectivamente. Se reporta errores que desde -1.4%
hasta 6.3% para tres correlaciones (Chapman-Enskog, Wilke-Lee, Fuller-Schettler-Gidding), en el caso
del método Stefan se reporta un error de -1,4%.

1
II. INTRODUCCIÓN

En un sistema compuesto por dos o más componentes en el cual las concentraciones varían de un punto a
otro del sistema, se produce una tendencia natural de transportar masa de un punto de mayor
concentración a un punto de menor concentración, lo cual hace a la larga que la diferencia de
concentraciones se mantenga al mínimo.

La transferencia de masa tiene un rol importante en diversos campos de la ingeniería química como por
ejemplo su influencia en la reacciones catalíticas heterogéneas en las cual la velocidad de difusión
determina la residencia en los poros del catalizador con lo que es factor importante a tomar en cuenta
para el diseño de reactores de este tipo, por otro lado tenemos en cuenta como un factor importante para
operaciones como adsorción y membranas. Un alcance importante también se dio en la instrumentación,
en la cual juega un rol vital en el diseño columnas cromatográficas, la fase móvil es difunde a través de la
fase inerte y está estrechamente relacionado con los coeficiente de difusividad, por lo que se logra
determinar de qué sustancia se trata en función de que tan rápido se difundan en la fase inerte.

El objetivo de la práctica es determinar el coeficiente de difusión de n-pentano en aire a la temperatura de


27°C y 756 mmHg y comparar este valor con los calculados con las correlaciones Chapman-Enskog,
Wilke-Lee, Fuller-Schettler-Gidding.

2
III. PRINCIPIOS TEÓRICOS

El transporte molecular de materia se describe a partir de la ley de Fick, la cual establece que el flujo de
masa del componente A por unidad de área de sección transversal perpendicular a la dirección de flujo es
proporcional a su gradiente de concentración. Lo anterior se expresa como:

(1)
Donde JAz, es la densidad de flujo molar de A en la dirección z, c es la concentración molar global en el
sistema, yA es la fracción molar de la especie A y DAB es el coeficiente de difusión molecular o
difusividad másica.

3.1. Difusividad másica en fase gaseosa

Existen varias ecuaciones semiempíricas que determinan el coeficiente de difusividad a partir de la


teórica cinética de los gases.
Champan y Enskog (1954) relacionaron las propiedades de los gases con las fuerzas intermoleculares.
Usando el potencial de Lennard-Jones para relacionar las fuerzas de atracción y repulsión entre átomos.
0.00266𝑇 3/2
𝐷𝐴𝐵 = (2)
𝑃𝑀𝐴𝐵 1/2 𝜎 2 𝐷

La correlación de Wilky-Lee usada para mezclas binarias no polares. Los supuestos inherentes de estas
ecuaciones son bastante restrictivos (es decir, átomos esféricos de baja densidad), y la función del
potencial intrínseco es empírica. A pesar de eso, proporcionan buenas estimaciones de D AB para
muchos gases poliatómicos y mezclas de gases, hasta alrededor de 1000 K y un máximo de 70 atm.

[3.03−(0.98/𝑀𝐴𝐵 1/2 ](10−3 )𝑇 3/2


𝐷𝐴𝐵 = (3)
𝑃𝑀𝐴𝐵 1/2 𝜎 2 𝐷

Donde σAB el diámetro de colisión en Ả (parámetro de Lennard-Jones) y Ω𝐷 la integral de colisión. DAB


es la difusividad en cm2/s y P es la presión en bar. MAB es el peso molecular promedio de A y B en
g/mol o kg/kmol

Fuller, Schettler y Giddings (1996) desarrollaron una ecuación satisfactoria (con margen de error
inferior al 7%) que resulta del ajuste de una curva de datos experimentales:
0.00143𝑇 1.75
𝐷𝐴𝐵 = 1/3 1/3 2
(4)
𝑃𝑀𝐴𝐵 1/2 [(∑ 𝑣)𝐴 +(∑ 𝑣)𝐵 ]

Donde DAB tiene unidades de cm2/s; T es la temperatura absoluta en K y P la presión en bar. Los
términos ∑𝑣, son la suma de los volúmenes atómico de difusión de todos los elementos de cada
molécula. Esta expresión se cumple para gases polares y no polares.
Los parámetros utilizados en las ecuaciones se calcularon de la siguiente manera:
𝜀𝐴𝐵 = (𝜀𝐴 𝜀𝐵 )2 (5)
𝜎𝐴𝐵 = (𝜎𝐴 + 𝜎𝐵 )/2 (6)
𝐴 𝐶 𝐸 𝐺
𝐷 = + exp(𝐷𝑇 ∗ ) + exp(𝐹𝑇 ∗ ) + exp(𝐻𝑇 ∗ ) (7)
𝑇∗𝐵

Donde T* = kT/AB y las constantes: A = 1.06036; B = 0.15610; C = 0.1930; D = 0.47635; E =


1.03587; F = 1.52996; G = 1.76474 y H = 3.89411
1 1 −1
𝑀𝐴𝐵 = 2 [𝑀 + 𝑀 ] (8)
𝐴 𝐵

3
3.2. Método de Winkelmann
La difusividad del vapor de un líquido volátil en el aire puede determinarse convenientemente por el
método de Winklemann’s en el que el líquido está contenido en un tubo vertical de diámetro
estrecho, mantenido a temperatura constante, y se pasa una corriente de aire por la parte superior del
tubo para asegurar que la presión parcial del vapor se transfiere desde la superficie del líquido a la
corriente de aire por difusión molecular. La velocidad de transferencia de masa está dada por:
𝐶 𝐶
𝑁′𝐴 = 𝐷 ∗ ( 𝐿𝐴 ) ∗ (𝐶 𝑇 ) (9)
𝐵𝑚

Considerando la evaporación del líquido:


𝜌 𝑑𝐿
𝑁′𝐴 = ( 𝑀̅𝐿 ) ∗ ( 𝑑𝑡 )
Así:
𝜌 𝑑𝐿 𝐶 𝐶𝑇
( 𝑀̅𝐿 ) ∗ ( 𝑑𝑡 ) = 𝐷 ∗ ( 𝐿𝐴 ) ∗ (𝐶 )
𝐵𝑚

Integrando y poniendo L = L0 en t = 0

2𝐷𝑀̅ 𝐶 𝐶
𝐿2 − 𝐿0 2 = ( 𝜌𝐿
) ∗ ( 𝐶𝐴 𝑇 ) ∗𝑡
𝐵𝑚

2𝐷𝑀̅ 𝐶 𝐶
(𝐿 − 𝐿0 ) ∗ (𝐿 − 𝐿0 + 2𝐿0 ) = (
𝜌𝐿
) ∗ ( 𝐶𝐴 𝑇 ) ∗𝑡
𝐵𝑚

𝑡 𝜌
𝐿 𝐶 𝜌 𝐶
(𝐿−𝐿0 )
= (2𝐷𝑀̅
) ∗ (𝐶 𝐵𝑚
𝐶
𝐿 𝐵𝑚
) ∗ (𝐿 − 𝐿0 ) + (𝐷𝑀𝐶
̅̅̅̅̅̅̅̅̅̅
𝐶
) ∗ 𝐿0 (10)
𝐴 𝑇 𝐴 𝑇

𝑡
Si s es la pendiente de un gráfico de (𝐿−𝐿 ) contra (𝐿 − 𝐿0 ), entonces:
0

𝜌𝐿 𝐶𝐵𝑚
𝑠=( ̅ 𝐶𝐴 𝐶𝑇
) y (11)
2𝐷𝑀

(𝜌 𝐶𝐵𝑚 )
𝐷 = 𝑠(2𝐶𝐿 ̅)
(12)
𝐴 𝐶𝑇 𝑀

La siguiente ecuación se utilizó la ecuación de Riedel para el cálculo de la Presión de vapor:


𝐶2 𝐶3
𝑃𝑣 = exp(𝐶1 + 𝑇
+ 𝑙𝑛𝑇 + 𝐶4𝑇 5 ) (13)

Válida en el rango de 143.2<T<469.7 para el n-pentano y las constantes son:

C1 = 78.741; C2 = -5 420.3; C3 = -8.8253; C4 = 9.6171E-6 y C5 = 2


Para el cálculo de la densidad del n-pentano líquido se utilizó:
𝑇 4
[1+(1− ) ·]
𝜌 = 𝐶1/𝐶2 𝐶3 (14)

Donde ρ está en mol/dm3 o kmol/m3 y T en K

Las constantes para el n-pentano son: C1= 0.84947; C2 = 0.26726; C3 = 469.7 y C4 = 0.27789

4
IV. DESARROLLO EXPERIMENTAL

Llenar el tubo capilar con una muestra de n-pentano hasta una altura aproximada de 35 mm. Colocar el tubo
capilar en el agujero que se encuentra en el centro de la tapa. Conectar el tubo flexible de aire a uno de los
extremos de la pieza “T”, por donde circulará una corriente de aire. Prender la bomba y verificar que la
velocidad de la corriente de aire sea baja. Prender el equipo y fijar la temperatura de trabajo (27°C) con el
control de temperatura. Cuando el sistema se encuentre estable, fijar una altura en el menisco del líquido de
trabajo (Lo). La escala del vernier debe ubicarse en una posición adecuada la cual sirve de referencia. En ese
instante es el tiempo cero. A partir de ese tiempo se realizan las mediciones de altura (L) cada 15 minutos,
encontrando el menisco de la acetona en el tubo capilar para cada medida.

Aire
L(t) Lo

Figura IV-1 Diagrama experimental

Descripción
 El sistema cuenta con un microscopio y un vernier calibrado que permiten obtener la altura del menisco
inicial (Lo) y en un tiempo cualquiera (L(t)).
 Así mismo, cuenta con una bomba que impulsa aire a una velocidad constante.
 También cuenta con un sistema de control de temperatura. En el diagrama solo se muestra el transmisor
que nos informa de la temperatura del sistema.

5
V. TABLA DE DATOS EXPERIMENTALES

En la Tabla V-1 se presentan las longitudes del n-pentano (nC5) contenido en el tubo de vidrio, L en mm,
en el transcurso del tiempo, t en ks, y las temperaturas en °C. Se realizó tres corridas a las mismas
condiciones de temperatura (27°C) y la misma presión Pa = 756 mmHg, a diferentes tiempos por lo que la
longitud inicial no es la misma. Se observa que las longitudes van incrementándose con el tiempo, debido a
la óptica del microscopio que produce el efecto contrario a lo que realmente está sucediendo, que es la
disminución de la longitud en el tubo de vidrio por la difusión del n-pentano en el aire.
Tabla V-1
Datos experimentales de longitud de n-pentano, L, mm, en el tubo delgado de vidrio en función del tiempo,
t en ks, y las temperaturas correspondientes
Corrida Nº1 Corrida N°2 Corrida N3

t, ks L, mm T, ºC t, ks L, mm T, ºC t, ks L, mm T, ºC
1 0.0010 22.0 26.9 0.01 22.4 27.1 0.00 21.0 27.4
2 0.0018 22.1 27.0 0.05 22.4 27.1 0.06 21.3 27.0
3 0.0024 22.1 26.9 0.09 22.5 26.9 0.15 21.5 26.9
4 0.93 23.2 26.9 1.09 23.7 27.3 1.64 23.0 27.3
5 0.93 23.3 27.1 1.13 23.7 27.3 1.79 23.2 27.2
6 0.96 23.3 26.9 1.21 23.8 27.2 1.84 23.3 26.9
7 1.80 24.2 26.9 2.02 24.9 26.9 3.81 25.7 27.2
8 1.83 24.3 26.9 2.07 25.0 27.1 3.88 25.7 27.0
9 5.16 28.2 27.0 2.09 25.0 27.1 3.94 25.8 27.2
10 5.17 28.2 27.1 2.80 25.8 27.3 3.99 25.9 27.3
11 5.18 28.3 26.9 2.84 25.8 26.9 4.01 25.9 26.9
12 5.19 28.3 27.1 2.88 25.9 27.1 4.04 26.0 27.1
13 6.15 29.2 26.9 3.80 26.9 27.3 5.87 28.2 27.6
14 6.14 29.3 27.0 3.86 27.0 27.1 5.93 28.3 26.9
15 6.15 29.3 27.1 3.88 27.0 27.2 5.97 28.4 27.4
16 7.08 30.2 26.9 4.77 28.0 26.9 7.24 29.5 27.0
17 7.10 30.2 26.9 4.80 28.0 27.0 7.27 29.6 27.5
18 7.11 30.3 26.9 4.82 28.0 26.8 7.30 29.6 27.1
19 8.11 31.3 27.0 6.16 29.4 27.1 8.57 31.0 27.0
20 8.12 31.4 27.1 6.22 29.5 27.3 8.60 31.0 27.2
21 8.16 31.4 27.0 6.23 29.5 26.9 8.63 31.1 27.1
22 9.24 32.5 27.1 7.64 31.0 27.3 10.07 32.5 28.0
23 9.25 32.5 27.1 7.67 31.0 27.0 10.11 32.6 27.3
24 9.26 32.5 27.5 7.78 31.0 26.9 10.13 32.6 27.1
25 10.21 33.5 27.3 9.37 33.0 27.3 11.24 33.8 27.6
26 10.22 33.5 27.1 9.44 33.0 27.0 11.27 33.8 27.3
27 10.22 33.6 27.2 9.46 33.0 26.9 11.31 33.8 27.2
28 11.41 34.7 27.0 11.01 34.5 26.9 12.94 35.4 27.1
29 11.42 34.8 27.0 11.09 34.5 26.9 13.00 35.5 27.3
30 11.42 34.8 27.2 11.13 34.5 27.0 13.02 35.5 27.2
31 11.43 34.8 27.3 12.26 35.7 27.2 14.83 37.2 27.1
32 12.33 35.8 27.2 14.86 37.2 27.3
33 12.33 35.8 26.9 14.88 37.3 27.0
34 13.39 36.8 27.1 16.44 38.7 27.2
35 13.44 36.9 27.0 16.47 38.7 27.0
36 13.47 36.9 26.9 16.50 38.7 27.2
37 14.88 38.2 27.2 17.54 39.6 27.3
38 14.91 38.2 27.3 17.57 39.6 27.2
39 14.94 38.2 27.2 17.59 39.7 27.3
6
VI. TABLA DE RESULTADOS
En la Tabla VI-1 se presentan los cálculos para la realización de la gráfica t/(L-Lo) en función de (L-Lo) que
se muestra en la Figura XI-1, en el cual se observan las curvas de las tres corridas realizadas. Se considera
solo la parte lineal de la curva (FiguraXI-2) para obtener el valor de la pendiente y a partir de ella calcular
las difusividades del n-pentano. Se muestran también la temperatura promedio en ºC, la pendiente m en
unidades de ks/mm2 y el coeficiente de correlación R (=√𝑅 2 )
Tabla VI-1
Datos calculados para el cálculo de la difusividad del n-pentano en aire a 27ºC y 760 mmHg
Corrida N°1 Corrida N°2 Corrida N°3

L-Lo, mm t/(L-Lo), ks/mm L-Lo, mm t/(L-Lo), ks/mm L-Lo, mm t/(L-Lo), ks/mm
1 0.0 0.000 0.0 0.000 0.0 0.000
2 0.1 0.018 0.0 0.000 0.3 0.216
3 0.1 0.024 0.1 0.877 0.5 0.301
4 1.2 0.774 1.3 0.837 2.0 0.818
5 1.3 0.742 1.3 0.870 2.2 0.812
6 1.3 0.771 1.4 0.864 2.3 0.800
7 2.2 0.819 2.5 0.806 4.7 0.810
8 2.3 0.794 2.6 0.795 4.7 0.826
9 6.2 0.833 2.6 0.803 4.8 0.822
10 6.2 0.834 3.4 0.825 4.9 0.814
11 6.3 0.822 3.4 0.836 4.9 0.818
12 6.3 0.823 3.5 0.822 5.0 0.808
13 7.2 0.855 4.5 0.845 7.2 0.815
14 7.3 0.841 4.6 0.838 7.3 0.812
15 7.3 0.843 4.6 0.845 7.4 0.807
16 8.2 0.864 5.6 0.852 8.5 0.852
17 8.2 0.865 5.6 0.858 8.6 0.845
18 8.3 0.856 5.6 0.861 8.6 0.848
19 9.3 0.872 7.0 0.880 10.0 0.857
20 9.4 0.864 7.1 0.876 10.0 0.860
21 9.4 0.868 7.1 0.877 10.1 0.854
22 10.5 0.880 8.6 0.888 11.5 0.876
23 10.5 0.881 8.6 0.891 11.6 0.875
24 10.5 0.882 8.6 0.905 11.6 0.873
25 11.5 0.888 10.6 0.884 12.8 0.878
26 11.5 0.888 10.6 0.891 12.8 0.880
27 11.6 0.881 10.6 0.892 12.8 0.883
28 12.7 0.899 12.1 0.910 14.4 0.899
29 12.8 0.895 12.1 0.916 14.5 0.896
30 12.8 0.892 12.1 0.920 14.5 0.898
31 12.8 0.893 13.3 0.922 16.2 0.915
32 13.4 0.920 16.2 0.917
33 13.4 0.920 16.3 0.913
34 14.4 0.930 17.7 0.929
35 14.5 0.927 17.7 0.931
36 14.5 0.929 17.7 0.932
37 15.8 0.942 18.6 0.943
38 15.8 0.944 18.6 0.944
39 15.8 0.946 18.7 0.941
T, ºC 27.0 27.1 27.2
m 0.0090 0.0090 0.0084
R 0.9633 0.9763 0.9880
7
En la Tabla VI-2 se presentan las condiciones de operación a la que se trabajó la difusión de vapor de n-
pentano en aire, presión atmosférica, Pa en bar (756mmHg) y las temperaturas promedio en ºC de las
corridas 1, 2 y 3 a la cual se evaluó las propiedades del n-pentano (nC5): presión de vapor PV en kPa y
densidad ρnC5 en kg/m3 obtenidas mediante la ecuación de Riedel (ec. 13) y la ec. (14) respectivamente;
̅𝑛𝐶5 y 𝑀
los pesos moleculares del n-pentano y aire, 𝑀 ̅𝑎𝑖𝑟𝑒 en g/mol. Estas condiciones de operación y
propiedades que se utiliza para el cálculo de la difusividad experimental. Se observa que la presión de
vapor y densidad del n-pentado con con un ligero, estas se trabajó por separado para el cálculo de la
difusividad con la pendiente correspondiente a cada corrida.

Tabla VI-2
Condiciones de operación y Propiedades de la n-pentano

Pa, bar T, °C PV, kPa ρnC5 (kg/m3) ̅ 𝒏𝑪𝟓 , g/mol


𝑴 ̅ 𝒂𝒊𝒓𝒆 , g/mol
𝑴

27.0 73.73 619.7


1.008 27.1 73.84 619.6 72.149 28.96
27.2 74.17 619.5

En la Tabla VI-3 se muestra la concentración molar total (n-pentano y aire), concentración molar de
saturación del n-pentano en la interfase L-V (CA), concentración molar del aire en la corriente de aire, CB1,
y en la superficie del n-pentano, CB2, y la concentración molar media logarítmica de vapor, CBM, todas en
kmol/m3 a las condiciones de temperatura mostradas en la Tabla VI-2 utilizadas en el cálculo de la
difusividadad de n-pentano en aire.

Tabla VI-3
Concentraciones de los fluidos y coeficiente del n-pentano en aire calculado por el método de Winklemann's
CT , C A, CB1, CB2, CBM, m, D D 𝑫𝒑𝒓𝒐𝒎 I.C
Corrida
kmol/m3 kmol/m3 kmol/m3 kmol/m3 kmol/m3 ks/mm2 m2/s cm2/s cm2/s 95%
1 0,0404 0,0295 0,0404 0,0108 0,0225 0,0091 8,89E-06 0,0889 0.0956
2 0,0404 0,0296 0,0404 0,0108 0,0224 0,0090 8.96E-06 0,0896 0,0912 -
3 0,0404 0,0297 0,0404 0,0107 0,0223 0,0084 9,51E-06 0,0951 0.0868

En la Tabla VI-4 se presentan la energía y longitud característica del sistema n pentano (A) – aire (B),
AB/k y AB, calculados a partir de las energías y longitudes características de Lennard Jones para cada
componente (Ver Tabla XI-1), además se muestra la integral de colisión difusional estimada a partir de la
correlación de Neufield (ec. 7) utilizando estos potenciales de Lennard Jones. También se muestra los
volúmenes molares de difusión del n pentano y aire; para el primer componente se calcula a partir de los
volúmenes atómicos (C y H) y para el segundo se encontró el valor en la literatura (Ver Tabla XI-2). Estos
parámetros se utilizan para la estimación del coeficiente de difusión utilizando tres correlaciones,
Chapman-Enskog, Wilke-Lee y Fuller-Schettler-Gidding y compararlos con el valor promedio obtenido
experimentalmente (Tabla VI-5)

8
Tabla VI-4
Potenciales de Lennard Jones Jones y volúmenes molares de difusión para el cálculo de la difusividad del n-
pentano en aire utilizando las correlaciones Chapman-Enskog, Wilke-Lee y Fuller-Schettler-Gidding

 /k AB, K  AB , Å D ν nC5, cm3/mol ν aire, cm3/mol

163.74 4.748 1.109 107.22 19.7

En la Tabla VI-5 se muestran los valores de coeficiente de difusión calculados por las tres correlaciones,
Chapman-Enskog, Wilke-Lee y Fuller-Schettler-Gidding, a las condiciones de operación (27º C y 1.008 bar),
además se muestra un valor experimental brindado por xxxx obtenido por el método Stefan, este valor se
extrapoló para T=27ºC ya que la solo proporcionaba el coeficiente de difusión hasta temperatura de 298.15K
(Ver figura XI-3). Estos cuatro valores de coeficiente de difusión se compara con el obtenido
experimentalmente y se muestra el porcentaje de error.

Tabla VI-5
Comparación del coeficiente de difusión experimental del n-pentano en aire a 27º C y 756mmHg con tres
correlaciones y otro valor obtenido experimentalemente por el método Stefan.

DnC5- aire Er,%


Chapman-Enskog 0,0854 6.3
Wilke-Lee 0,0924 -1.4
Fuller-Schettler-Gidding 0,0861 5.6
Experimental 0,0912

VII. DISCUSIÓN DE RESULTADOS

En la Figura X-1 se observa que a partir de la longitud efectiva (L-Lo) = 2 mm la tendencia de las tres
curvas son lineales, lo cual indica que a partir de esa longitud la velocidad de difusión del n-pentano en el
aire se mantiene constante (mm/ks).

En la Tabla VI-3 Se observa que estas las concentraciones de los fluidos varían ligeramente con la
variación de la temperatura (0.1 ºC) y los coeficientes de difusión varían entre 0.0889 y 0.0951; debido a
que se trabaja a las misma condiciones (756mmHg y 27ºC) con ligeras variaciones en la temperatura, se
opta por obtener un valor promedio de estos coeficientes ya que se esperaría que ambas difusividades
sean iguales. Las variaciones se deban probablemente a errores sistemáticos. Se opta por brindar un
intervalo de confianza del 95% (𝑥̅ ± 1.96/√𝑁 = 0.00912 ± 0.0044), para el valor de difusividad el cual
indica que el coeficiente de difusividad estaría dentro del intervalo 0.0868 y 0.0956 a las condiciones de
27ºC y 756 mmHg.

Las correlaciones usadas para estimar la difusividad del n-pentano en aire presentan errores de 1.3 a
6.3%. La comparación conduce a una concordancia entre los valores teóricos de los coeficientes de
difusión y la evidencia experimental con errores menores al 7%, siendo la correlación de Wilkee-Lee la
que nos permite realizar una mejor estimación del coeficiente de difusión del sistema n-pentano-aire a las
9
condiciones trabajadas con un error de -1.3%, este valor calculado 0.924 cm2/s está dentro del intervalo
de confianza del coeficiente calculado experimentalmente (0.0868-0.0956)

VIII. CONCLUSIONES

El coeficiente de difusión del n-pentano en aire a 27ºC y 756 mmHg obtenido por el método de
Winklemann es 0.0912 cm2/s.

La correlación que brinda una mejor estimación del coeficiente de difusión del n-pentano en aire es de
Wilkee-Lee a las condiciones trabajadas.

IX. RECOMENDACIONES

Realizar dos o tres corridas por alumno a las mismas condiciones para ver la reproducibilidad de los
datos.

Para obtener un mejor resultado del sistema n-pentano-aire se recomienda insertar aire seco al sistema, ya
que la humedad podría interferir en el valor de coeficiente de difusión.

Realizar corridas a temperaturas entre 15-25 ºC, ya que existe en la literatura valores experimentales
realizados con otros métodos (p.e. método Stefan) y compararlos, además de estimar la mejor correlación
para los datos de coeficiente de difusión obtenidos y evaluar la dependencia del coeficiente de difusión
con la temperatura.

Realizar la experiencia con otras sustancias como acetona o el hexano o cambiar el tipo de fluido (aire)
por otro gas como por ejemplo helio y con ello verificar la influencia de la humedad en el sistema.

X. BIBLIOGRAFÍA

Perry, R. H., & Green, D. W. (2008). Heat and Mass Transfer. En Perry's Chemical Engineers' Handbook
(Octava ed., págs. 698-779). United States, New York: McGraw Hill.

Poling, B. E., Praustniz, J. M., & O'Connell, J. P. (2001). Diffusion Coefficients. En The properties of gases
and liquids (Quinta ed., pág. 803). McGraw-Hill.

10
XI. ANEXOS

11.1. Ejemplo de cálculos

11.1.1. Cálculo del coeficiente de difusión Daire-nC5 experimental a 27.2 ºC


Reemplazando el valor de la pendiente (Tabla VI-1 y Figura XI-1) , las propiedades del los
fluidos (Tabla VI-2) y concentraciones (Tabla VI-3) en la ecuación 12 se obtiene:
619.5 × 0.0223
𝐷aire−nC5 =
2× 8.40 × 106 × 72.149 × 0.0297 × 0.0404

𝑫𝐚𝐢𝐫𝐞−𝐧𝐂𝟓 = 𝟗. 𝟓𝟏 × 𝟏𝟎−𝟔 𝒎𝟐 /𝒔 = 𝟎. 𝟎𝟗𝟓𝟏 𝒄𝒎𝟐 /𝒔

Del mismo modo se calcula para las dos corridas restantes

- Concentración molar total, CT a 27.2ºC y 756mmHg


𝑃2 𝑃1 𝑉1
=
𝑇2 𝐶𝑇 𝑇1 𝑛1
756𝑚𝑚𝐻𝑔 1𝑘𝑚𝑜𝑙 273.15
𝐶𝑇 = × 3
×
760𝑚𝑚𝐻𝑔 22.4 𝑚 (27.2 + 273.15)
→ 𝑪𝑻 = 𝟎. 𝟎𝟒𝟎𝟒 𝒌𝒎𝒐𝒍/𝒎𝟑
- Presión de vapor del n-pentano, Pv
Utilizando la siguiente correlación de la ec. (13)
𝐶2
+𝐶3𝑙𝑛𝑇+𝐶4𝑇5
𝑃𝑣 = 𝑒 𝐶1+ 𝑇
Reemplazando:
−5420.3
78.741+ +(−8.8253) ln(27.2+273.15)+9.6171𝐸−6×(27.2+273.15)5
𝑃𝑣 = 𝑒 (27.2+273.15)

𝑷𝒗 = 𝟕𝟒. 𝟏𝟕𝒌𝑷𝒂
- Densidad del n-pentano
Utilizando la siguiente correlación:
𝐶1 3
𝜌= 𝑇 , 𝑘𝑚𝑜𝑙/𝑚
[1+(1− )𝐶4 ]
𝐶2 𝐶3

Dónde, los valores de las constantes para el n-pentano son:


C1 = 0.84947
C2 = 0.26726
C3 = 469.7
C4 = 0.27789
Reemplanzando:
0.84947 𝑘𝑚𝑜𝑙 𝑘𝑔
𝜌𝑛𝐶5 = 27.2+273.15 0.27789 3
× 72.149 → 𝝆𝒏𝑪𝟓 = 𝟔𝟏𝟗. 𝟓 𝒌𝒈/𝒎𝟑
[1+(1− ) ] 𝑚 𝑘𝑚𝑜𝑙
0.26726 469.7

- Concentración molar del aire en la corriente de aire, CB1, y en la superficie del n-pentano, CB2.
𝐶𝐵1 = 𝐶𝑇 = 0.0404 𝑘𝑚𝑜𝑙/𝑚3

11
𝑃𝑎𝑖𝑟𝑒 𝑃𝑎𝑡𝑚 − 𝑃𝑣 100.79 − 74.17
𝐶𝐵2 = 𝑦𝑎𝑖𝑟𝑒 𝐶𝑇 = ( ) × 𝐶𝑇 = × 𝐶𝑇 = × 0.0404
𝑃𝑎𝑡𝑚 𝑃𝑎𝑡𝑚 100.79
𝐶𝐵2 = 0.0107 𝑘𝑚𝑜𝑙/𝑚3
- Concentración molar media logarítmica de vapor, CBm

𝐶𝐵1 − 𝐶𝐵2 0.0404 − 0.0107


𝐶𝐵𝑚 = = → 𝑪𝑩𝒎 = 𝟎. 𝟎𝟐𝟐𝟑
𝐶 0.0404
ln(𝐶𝐵1 ) ln(0.0107)
𝐵2

- Concentración molar de saturación del n-pentano, CnC5, en la interfase L-V


𝐶𝐴 = 𝐶𝑛𝐶5 = 𝐶𝑇 − 𝐶𝑎𝑖𝑟𝑒 = 0.0404 − 0.0107 → 𝑪𝒏𝑪𝟓 = 𝟎. 𝟎𝟐𝟗𝟕 𝒌𝒎𝒐𝒍/𝒎𝟑

11.1.2. Cálculo del coeficiente de difusión Daire-nC5 a 27.2 ºC, utilizando tres correlaciones

- Diámetro de colisión, AB. Se utiliza la ecuación (6)


Dónde:
A: n-pentano
B: aire
Para el aire: 𝜎𝐵 = 3.711 𝐴̇ (Poling, Praustniz, & O'Connell, 2001)
Para el n-pentano: 𝜎𝐴 = 5.784 𝐴̇ (Poling, Praustniz, & O'Connell, 2001)
Reemplazando en la ec. (6)
∴ 𝝈𝑨𝑩 = 𝟒. 𝟕𝟒𝟖 𝑨̇
- Cálculo de AB/k
Para el aire: 𝜀𝐵 /𝑘 = 78.6 𝐾 (Poling, Praustniz, & O'Connell, 2001)
Para el n-pentano: 𝜀𝐴 /𝑘 = 341.1 𝐾 (Poling, Praustniz, & O'Connell, 2001)
Reemplazando en la ec. (5)
𝜀𝐴𝐵
= √78.6 × 341.1
𝑘
𝜀𝐴𝐵
= 163.74 𝐾
𝑘
- Integral de colisión difusional, D
Reemplazando los valores obtenidos AB/T en las ecuación (7)
𝑘𝑇 27.2 + 273.15
𝑇∗ = = = 1.834
𝐴𝐵 163.74
1.06036 0.1930 1.03587 1.76474
𝐷 = 0.15610
+ + +
1.834 exp(0.47635 × 1.834) exp(1.52996 × 1.834) exp(3.89411 × 1.834)
∴ 𝑫 = 𝟏. 𝟏𝟎𝟗
- Volúmenes de difusión molares, vi
Para el aire (∑ 𝒗𝒊 )𝑩 = 𝟏𝟗. 𝟕 𝒄𝒎𝟑 /𝒎𝒐𝒍 (Poling, Praustniz, & O'Connell, 2001)
Para el n-pentano: (∑ 𝒗𝒊 )𝑨 = 5𝑣𝐶 + 12𝑣𝐻 = 5 × 15.9 + 12 × 2.31 = 𝟏𝟎𝟕. 𝟐𝟐 𝒄𝒎𝟑 /𝒎𝒐𝒍

- Masa molar promedio, reemplazando en la ec. (8)


12
1 1 −1
𝑴𝑨𝑩 = 2 [ + ] = 𝟒𝟏. 𝟑𝟑 𝒌𝒈/𝒌𝒎𝒐𝒍
72.149 28.96

- Correlación Chapman-Enskog (ec. 2)

0.00266 × 300.353/2
𝐷𝐴𝐵 =
1.008 × 41.331/2 4.7482 × 1.109
𝑫𝑨𝑩 = 𝟖. 𝟓𝟓 × 𝟏𝟎−𝟔 𝒎𝟐 /𝒔
𝑫𝑨𝑩 = 𝟎. 𝟎𝟖𝟓𝟓 𝒄𝒎𝟐 /𝒔
- Correlación Wilke-Lee (ec. 3)
[3.03 − (0.98/41.331/2 ](10−3 ) × 300.353/2
𝐷𝐴𝐵 =
1.008 × 41.331/2 4.7482 × 1.109
𝑫𝑨𝑩 = 𝟗. 𝟐𝟓 × 𝟏𝟎−𝟔 𝒎𝟐 /𝒔
𝑫𝑨𝑩 = 𝟎. 𝟎𝟗𝟐𝟓 𝒄𝒎𝟐 /𝒔
- Correlación Fuller-Schettler-Giddings (ec. 4.)
0.00143 × 300.351.75
𝐷𝐴𝐵 =
1.008 × 41.331/2 [107.221/3 + 19.71/3 ]2
𝑫𝑨𝑩 = 𝟖. 𝟔𝟏 × 𝟏𝟎−𝟓 𝒎𝟐 /𝒔
𝑫𝑨𝑩 = 𝟎. 𝟎𝟖𝟔𝟏 𝒄𝒎𝟐 /𝒔
- Errores
𝐷𝑒𝑥𝑝 − 𝐷𝑐𝑜𝑟𝑟𝑒𝑙.
𝐸% = × 100%
𝐷𝑒𝑥𝑝
Correlación Chapman-Enskog:
0.0912 − 0.0855
𝑬% = × 100% = 𝟔. 𝟑%
0.0912
Los resultados se muestran en la Tabla VI-4 y VI-5

13
11.2. Gráficas

1.0
0.9
0.8
t/(L-Lo), ks/mm 0.7
0.6
Corrida 1
0.5
Corrida 2
0.4
Corrida 3
0.3
Profesora
0.2
0.1
0.0
0 5 10 15 20
(L-Lo), mm

Figura XI-1 Curva para la determinación del coeficiente de difusión de vapor n-pentano en aire

1.0
Corrida1 = 0.0091x + 0.7804
R² = 0.9280
1.0 Corrida2: y = 0.0090x + 0.8122
R² = 0.9532

0.9
t/(L-Lo), ks/mm

Corrida3: y = 0.0084x + 0.7792


R² = 0.9762
0.9

0.8
Corrida 1

0.8 Corrida 2
Corrida 3
0.7
0 5 10 15 20
(L-Lo), mm
Figura XI-2 Parte lineal de las curvas t/(L-Lo) vs (L-Lo) para la determinación de las pendientes,
para las tres corridas

14
11.3. Tablas de Propiedades

Tabla XI-1 Potenciales de Lennard-Jones para el aire y n-pentano (Poling, Praustniz, & O'Connell,
2001)

15
Tabla XI-2
Volúmenes de difusión atómica (Poling, Praustniz, & O'Connell, 2001)

Tabla XI-3
Coeficientes de difusión de n-pentano en aire