A/E ARCHITECT/ENGINEER
AAMA AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
AB ANCHOR BOLT
ABC AGGREGATE BASE COURSE
AC ASBESTOS CEMENT OR ASPHALTIC
CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACS PNL ACCESS PANEL
ACST ACOUSTIC
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGA AMERICAN GAS ASSOCIATION
AGC ASSOCIATED GENERAL CONTRACTORS
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP DETAIL TITLE / ARCHITECTURAL
AMPERE ABBREVIATIONS
AMT AMOUNT
ANOD ANODIZE
SCALE : NONE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-01.DWG
ANT ANTENNA
AISC AMERICAN INSTITUTE OF STEEL
CONSTRUCTION
ALT ARCHITECTURAL
ALTERNATEABBREVIATIONS
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS
INSTITUTE
ANT ANTENNA
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL
INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND
MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING
INSTITUTE
AWPA AMERICAN WOOD PRESERVERS'
ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
C CELSIUS CHANNEL
C CHANNEL CELSIUS
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
C TO C CENTER TO CENTER
CAB CABINET
CAC CEILING ATTENUATION CLASS
COM COMMON
COMB COMBINATION, COMBINED
SCALE : NONE
COMM COMMUNICATION
COMP COMPONENT
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-04.DWG
CNR CORNER
CNTR COUNTER
CO ARCHITECTURAL ABBREVIATIONS
CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CO₂ CARBON DIOXIDE
COL COLUMN
COM COMMON
COMB COMBINATION, COMBINED
COMM COMMUNICATION
COMP COMPONENT
CONC CONCRETE
CONC FLR CONCRETE FLOOR
COND CONDENSER OR CONDITION
CONF CONFERENCE
CONN CONNECT
CONSTR CONSTRUCTION
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CORR CORRIDOR
CPM CRITICAL PATH METHOD
CPRS COMPRESSIBLE
CPT CARPET
CRS COLD ROLLED STEEL
CRSI CONCRETE REINFORCING STEEL
INSTITUTE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSI CONSTRUCTION SPECIFICATIONS
INSTITUTE
CSK COUNTER SUNK
CSMT CASEMENT
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTG COATING
CTR CENTER CONTOUR
CTRL CONTROL
CTV CABLE TELEVISION
CU COPPER C
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD CUBIC YARD
CURT CURTAIN
CYL CYLINDER
DETAIL TITLE / ARCHITECTURAL ABBREVIATIONS
SCALE : NONE
D DEPTH OR PENNY (NAIL)
D LABEL CLASS D DOOR
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-05.DWG
DAT DATUM
CU FT CUBIC FEET
CU IN CUBIC INCH
CU YD ARCHITECTURAL ABBREVIATIONS
CUBIC YARD
CURT CURTAIN
CYL CYLINDER
CYL L CYLINDER LOCK
E EAST
E LABEL CLASS E DOOR
EA DETAIL
EACHTITLE / ARCHITECTURAL ABBREVIATIONS
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
SCALE : NONE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-06.DWG
EJ EXPANSION JOINT
DW DISHWASHER
DWG DRAWING
DWTR ARCHITECTURAL ABBREVIATIONS
DUMBWAITER
E EAST
E LABEL CLASS E DOOR
EA EACH
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRIC
ELEC DR OP ELECTRIC DOOR OPENER
ELEV ELEVATOR
EMER EMERGENCY
EMER SHR EMERGENCY SHOWER
ENCL ENCLOSURE
ENGR ENGINEER
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPDM ETHYLENE PROPYLENE DIENE
MONOMER
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESCAL ESCALATOR
ESMT EASEMENT
ESP ESPECIALLY
EST ESTIMATE
ETC AND SO FORTH OR ET CETERA
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP EXPANSION OR EXPOSED
EXP BT EXPANSION BOLT
EXST GR DETAIL TITLE / ARCHITECTURAL
EXISTING GRADE ABBREVIATIONS
F FAHRENHEIT OR FEMALE
FA FIRE ALARM
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS FASCIA
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD OR FLAT HEAD SCREWS
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHP FULL HEIGHT PARTITION
FHWS FLAT HEAD WOOD SCREW
FIG FIGURE
FIL FILLET
FIN FINISH
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIN WD FINISH WOOD
FIXT FIXTURE
FL FLOORLINE
FLASH FLASHING
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR
DETAIL TITLE SINK
/ ARCHITECTURAL ABBREVIATIONS
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM SCALE : NONE
FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-08.DWG
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF
FLDG FOLDING
FLEX FLEXIBLE
FLG ARCHITECTURAL
FLOORING ABBREVIATIONS
FLR FLOOR
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FLUOR FLUORESCENT
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FM-G FACTORY MUTUAL GLOBAL
FO FINISHED OPENING
FOC FACE OF CONCRETE OR FACE OF
CURB
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR
FRAME
FR SNK FLUSHING RIM SINK
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FRZ FREEZER
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET OR FOOT
FTG FOOTING
FURG FURRING
FURN FURNISH OR FURNITURE
FUT FUTURE
FWC FABRIC WALLCOVERING
H HIGH
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HB HOSE BIBB
HC HOLLOW CORE
HCWD HOLLOW CORE WOOD DOOR
HDBD HARDBOARD
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HM HECTOMETER
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HMDF DETAIL TITLE / METAL
HOLLOW DOOR
ARCHITECTURAL AND FRAME
ABBREVIATIONS
JAN JANITOR
J-BOX JUNCTION BOX
DETAIL TITLE / ARCHITECTURAL ABBREVIATIONS
JAN JANITOR
J-BOX JUNCTION BOX
L ANGLE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LH LEFT HAND
LHR LEFT HAND REVERSE
LHR LEFT HAND REVERSE LATENT HEAT
RATIO
LIB LIBRARY
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT
DETAIL TITLEGAGE
/ ARCHITECTURAL ABBREVIATIONS
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
SCALE : NONE
LVD LOUVERED
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-12.DWG
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LRG LARGE
LRV LOUVERED ROOF VENT
LS ARCHITECTURAL
LUMP SUMABBREVIATIONS
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACH MACHINE
MACH RM MACHINE ROOM
MAINT MAINTENANCE
MAN MANUAL
MATL MATERIAL
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MB MACHINE BOLT
MCB METAL CORNER BEAD
MD DECK
ME MECHANICAL ENGINEER
MEAS MEASURE
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MED MEDICAL MEDIUM
MED MEDIUM MEDICAL
MEK METHYL ETHYL KETONE
MEL MELAMINE
MEMB MEMBRANE
MEMO MEMORANDUM
MEZZ MEZZANINE
MF MILL FINISH
MFD MANUFACTURED
MFG MANUFACTURING
MFR MANUFACTURER
MFR REC MANUFACTURER'S RECOMMENDATION
MGT MANAGEMENT
MH MANHOLE
MIC MICROPHONE
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN DETAIL TITLE /MINIMUM
MINUTE ARCHITECTURAL ABBREVIATIONS
MIRR MIRROR
MISC MISCELLANEOUS
SCALE : NONE
MIT MITER
MKR MARKER
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-13.DWG
ML METAL LATH
MH MANHOLE
MIC MICROPHONE
MID ARCHITECTURAL
MIDDLE ABBREVIATIONS
MIL STD MILITARY STANDARD
MIN MINIMUM MINUTE
MIN MINUTE MINIMUM
MIRR MIRROR
MISC MISCELLANEOUS
MIT MITER
MKR MARKER
ML METAL LATH
MLDG MOLDING (MOULDING)
MLWK MILLWORK
mm MILLIMETER
MO MASONRY OPENING OR MOTOR
OPERATED
MOD MODEL, MODIFY OR MODULE
MOD BIT MODIFIED BITUMEN
MON MONITOR
MOPR MOP RACK
MR MOISTURE RESISTANT
MS MACHINE SCREW OR MOP SINK
MTD MOUNTED
MTG MOUNTING
MTL METAL
MULL MULLION
MW MICROWAVE
MWP MEMBRANE WATERPROOFING
N NORTH
NA NOT APPLICABLE
NAAMM NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL
MANUFACTURERS
NAT NATURAL
NATL NATIONAL
NC NOISE CRITERIA
NCOMBL NONCOMBUSTIBLE
NEC NATIONAL ELECTRICAL CODE
NEG NEGATIVE
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUT NEUTRAL
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC DETAIL
NOTTITLE
IN /CONTRACT
ARCHITECTURAL ABBREVIATIONS
NO NUMBER
NOM NOMINAL
SCALE : NONE
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-14.DWG
NRCA NATIONAL ROOFING CONTRACTORS
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUT ARCHITECTURAL
NEUTRAL ABBREVIATIONS
NFC NATIONAL FIRE CODE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NR NOISE REDUCTION
NRC NOISE REDUCTION COEFFICIENT
NRCA NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NRP NONREMOVABLE
NS NARROW STILE
NUM NUMERAL
OC ON CENTER
OCC OCCUPY
OCT OCTAGON
OD OUTSIDE DIAMETER OUTSIDE
DIMENSION
OD OUTSIDE DIMENSION OUTSIDE
DIAMETER
PARA PARAGRAPH
DRAIN
ORG ORGANIC
ORIG ARCHITECTURAL
ORIGINAL ABBREVIATIONS
ORN ORNAMENTAL
OSHA OCCUPATIONAL SAFETY AND HEALTH
ADMINSTRATION
OUT OUTLET
OZ OUNCE
PRCST PRECAST
PREFAB PREFABRICATE
SCALE : NONE
PREFIN PREFINISH
PRELIM PRELIMINARY
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-16.DWG
PREP PREPARATION
PNEU PNEUMATIC
PNL PANEL
PO ARCHITECTURAL ABBREVIATIONS
POST OFFICE PURCHASE ORDER
PO PURCHASE ORDER POST OFFICE
POLY POLYETHYLENE (PLASTIC)
PR PAIR
PRCST PRECAST
PREFAB PREFABRICATE
PREFIN PREFINISH
PRELIM PRELIMINARY
PREP PREPARATION
PRESS PRESSURE
PREV PREVIOUS
PRKG PARKING
PRMLD PREMOLDED
PROJ PROJECT
PROP PROPERTY
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT, PNEUMATIC TUBE, OR
PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PVC POLYVINYL CHLORIDE (PLASTIC)
PVG PAVING
PWR POWER
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QRY QUARRY
QT QUARRY TILE
QTB QUARRY TILE BASE
QTF QUARRY TILE FLOOR
QTR QUARTER
QTY QUANTITY
QUAD QUADRANT
QUAL QUALITY
R RADIUS OR RISER
RA RETURN AIR
RAD RADIATOR
RB RESILIENT BASE OR RUBBER BASE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REMOTE CONTROL
RCP REFLECTED
DETAIL CEILING ABBREVIATIONS
TITLE / ARCHITECTURAL PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
SCALE : NONE
REC RECESSED
RECD RECEIVED
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-17.DWG
RECPT RECEPTACLE
RB HK ROBE HOOK
RBM REINFORCED BRICK MASONRY
RBR ARCHITECTURAL
RUBBER ABBREVIATIONS
RC REMOTE CONTROL
RCP REFLECTED CEILING PLAN
RCVR RECEIVER
RD ROAD OR ROOF DRAIN
REC RECESSED
RECD RECEIVED
RECPT RECEPTACLE
RECT RECTANGLE
REF REFERENCE OR REFRIGERATOR
REFR REFRACTORY REFRIGERATION
SA SUPPLY AIR
SALV DETAIL TITLE / ARCHITECTURAL
SALVAGE ABBREVIATIONS
SAMP SAMPLE
SAN SANITARY
SCALE : NONE
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-18.DWG
SB SPLASH BLOCK
RVS REVERSE
RWD REDWOOD
RWL ARCHITECTURAL ABBREVIATIONS
RAIN WATER LEADER
SA SUPPLY AIR
SALV SALVAGE
SAMP SAMPLE
SAN SANITARY
SAT SUSPENDED ACOUSTICAL TILE
SATC SUSPENDED ACOUSTICAL TILE CEILING
SB SPLASH BLOCK
SBS STYRENE BUTADIEN STYRENE
SBSTR SUBSTRATE
SC SHADING COEFFICIENT OR SOLID CORE
SCH SCHOOL
SCHED SCHEDULE
SCHEM SCHEMATIC
SCP SCUPPER
SCRN SCREEN
SCT STRUCTURAL CLAY TILE
SCWD SOLID CORE WOOD DOOR
SD SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER;
SDG SIDING
SECT SECTION
SEG SEGMENT
SEL SELECT
SEP SEPARATE
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGD SLIDING GLASS DOOR
SGL SINGLE
SHR SHOWER
SHR HD SHOWER HEAD
SHRD SHOWER DRAIN
SHT SHEET
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKLT SKYLIGHT
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT DETAIL TITLE / ARCHITECTURAL
SEALANT ABBREVIATIONS
SM SHEET METAL
SMK SMOKE
SCALE : NONE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-19.DWG
SNDU SANITARY NAPKIN DISPOSAL UNIT
SJI STEEL JOIST INSTITUTE
SK SKETCH
SKLT ARCHITECTURAL
SKYLIGHT ABBREVIATIONS
SLD WDW HORIZONTAL SLIDING WINDOW
SLDG SLIDING
SLNT SEALANT
SM SHEET METAL
SMK SMOKE
SND SANITARY NAPKIN DISPENSER
SND INS SOUND INSULATION
SNDU SANITARY NAPKIN DISPOSAL UNIT
SPEC SPECIFICATION
SPKLR SPRINKLER
SPKR SPEAKER
SPLY SUPPLY
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SANITARY SEWER OR SERVICE SINK
SST STAINLESS STEEL
ST STAIRS OR STREET
STC SOUND TRANSMISSION CLASS
STD STANDARD
STIF STIFFENER
STL JST STEEL JOIST
STL LNTL STEEL LINTEL
STL PL STEEL PLATE
STL RF DK STEEL ROOF DECK
STL TB STEEL TUBE
STL TR STEEL TRUSS
STNLS STAINLESS
STOR STORAGE
STR STRINGERS
STRUCT STRUCTURAL
STRUCT STL STRUCTURAL STEEL
SUB SUBSTITUTE
SURF SURFACE
SUSP SUSPEND
SUSP CLG SUSPENDED CEILING
SV SHEET VINYL
SW SWITCH
SWDR SWING DOOR
SYM SYMBOL
SYNTH SYNTHETIC
SYS SYSTEM
SCALE : NONE
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT SCALE : NONE
ULTIMATE
UNFIN UNFINISH
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-21.DWG
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
TV TELEVISION
TYP TYPICAL
ARCHITECTURAL ABBREVIATIONS
U HEAT TRANSFER COEFFICIENT
UC UNDERCUT
UCD UNDERCUT DOOR
UGND UNDERGROUND
UL UNDERWRITERS LABORATORIES
ULT ULTIMATE
UNFIN UNFINISH
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV ULTRAVIOLET
V VOLT
VAC VACUUM
VAR VARIES
VCT VINYL COMPOSITION TILE VITRIFIED CLAY TILE
VEH VEHICLE
VENT VENTILATION
VERT VERTICAL
VEST VESTIBULE
VFAT VINYL FACED ACOUSTICAL TILE
VIC VICINITY
VID VIDEO
VIF VERIFY IN FIELD
VNR VENEER
VOC VOLATILE ORGANIC COMPOUND
VOL VOLUME
VOLT VOLTAGE
VP VENEER PLASTER
VR VAPOR RETARDER
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
VWF VINYL WALL FABRIC
W WIDE OR WEST
W/ WITH
W/O WITHOUT
WARR WARRANTY
WBL WOOD BLOCKING
WC WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD DETAIL TITLE COOLER,
WATER / ARCHITECTURAL
WALLABBREVIATIONS
HUNG
WD WOOD
WDW WINDOW
SCALE : NONE
WF WIDE FLANGE
WFAB WALL FABRIC
DATE ISSUED: DECEMBER 2008 CAD DETAIL NO.: SD000115-22.DWG
WFR WOOD FRAME
WARR WARRANTY
WBL WOOD BLOCKING
WC ARCHITECTURAL ABBREVIATIONS
WALL COVERING OR WATER CLOSET
WC WL HNG WATER CLOSET, WALL HUNG
WCHR WATER CHILLER
WCL WL MTD WATER COOLER, WALL HUNG
WD WOOD
WDW WINDOW
WF WIDE FLANGE
WFAB WALL FABRIC
WFR WOOD FRAME
WFS WOOD FURRING STRIPS
WH WATER HEATER
WHSE WAREHOUSE
WLD WELDED
WM WIRE MESH
WP WATERPROOFING
WPD WATER PRESSURE DROP
WPM WATERPROOF MEMBRANE
WR WEATHER RESISTANT
WS WEATHERSTRIP
WSCT WAINSCOT
WT WEIGHT
WWF WELDED WIRE FABRIC
SCALE : NONE
ELEVATION INDICATOR
DEMOLITION LINE
NEW LINE
PROPERTY LINE
SCALE : NONE
D2 DETAIL INDICATOR
A-512
D2
DETAIL INDICATOR
A-512
D2
A-512 DETAIL INDICATOR FOR SMALL CONDITIONS
DIMENSION LINE
A4 A4
A-201 A-201 ELEVATION INDICATOR, EXTERIOR
A2
C
A-202
B
ELEVATION INDICATOR, INTERIOR, MULTIPLE VIEW
A2
A-202 ELEVATION INDICATOR, INTERIOR, SINGLE VIEW
A4
BUILDING SECTION INDICATOR
A-201
SCALE : NONE
A3.1 A4.3
DETAIL INDICATOR
SHEET WHERE REF.
CORRIDOR
ROOM NAME AND NUMBER
C2
1 COLUMN GRID
A
22 KEYNOTE
CG CORNER GUARD
NORTH
NORTH ARROW
MATERIALS LEGEND
SCALE : NONE
TO UNDERSIDE OF
4'-0"
CANOPY OR REQUIREMENTS OF THE VEHICLE SIZE USED AT
BLDG. ABOVE
[1200mm]
13'-6" MIN.
CANOPY OR
[4115mm]
BLDG. ABOVE THE PROJECT LOCATION.
NOTE #4
NOTE #2
9'-6"
NOTE INCLUDE TWO-WAY RADIO ANTENNA.
ENTRANCE DETAILS
FOR HEAD-IN OR DRIVE THRU
GIVEN TO INCREASED CLEARANCE TO ALLOW FOR
UNLOADING
13'-0"
M
CANOPY OR
I
N
[3860mm]
.
R
4'-0" MIN.
SCALE : NONE
BLDG. ABOVE
T
A
O
U
D
U
R
I
[1200mm] 7'-O"
T
[1
N
U
S
S
I
N
[2130mm]
28
D
7'-0" 7'-0"
12'-0" [3660mm]
2
00
'
AREA FOR
-
[2130mm] [2130mm]
mm
LANE WIDTH/
[2440mm]
"
AMBALANCE
HANDLING
]
8'-0"
STRETCHER
[7315mm]
[7315mm]
24'-0"
24'-0"
MIN.
MIN.
STRETCHER
CANOPY OR
BLDG. ABOVE
REQ'D. FOR
DEPTH OF
WIDTH AS
*
DOOR(S)
13'-6" [4115mm]
DOOR OPENING
BACKWALL
CEILING OR
OVERHANG
CONSTRUCTION 2. INCLUDES ROOF MOUNTED EQUIPMENT, DOES
NOTE #4
9'-6" NOTE 1
6" [150mm] OR ACTUATOR NOTE INCLUDE TWO-WAY RADIO ANTENNA.
PLATFORM
[2900mm]
FOR AUTOMATIC
NOTE #2
DOOR 3. THIS DIMENSION IS A MINIMUM RECOMMENDATION.
THE COVERED AREA SHOULD BE DESIGNED IN
RESPONSE TO THE SPECIFIC CONDITIONS OF
7'-0" [2130mm]
EACH PROJECT: CLIMATE, ORIENTATION, SITE,
ETC.
ENTRANCE DETAILS
NOTE #3 CURB OR
14'-0" [4265mm] WHEEL STOP
4. 10'-0" [3050mm] IS ABSOLUTE MINIMUM PER
SCALE : NONE
M
BACKWALL LINE OF
I
13'-0"
N
.
CONSTRUCTION CANOPY OR
T
[3965mm]
O
U
D
OR ACTIVATOR
U
OVERHANG
T
[1
N
U
DOOR 7'-0"
S
FOR AUTOMATIC
I
N
28
D
13'-0"
G
ACTIVATOR
[2130mm]
E
DOOR
12'-0" [3660mm]
00
'
DEPTH AS [3965mm]
-
mm
0
"
13'-0" MIN.
[2440mm]
]
PLATFORM
8'-0"
ACTIVATOR
7'-0"
DEPTH AS
[2130mm] REQ'D.
[7315mm]
[7315mm]
24'-0"
24'-0"
7'-0" MIN.
[2130mm]
AREA FOR
MANEUVERING
STRETCHER OUT
OF AMBULANCE PLAN OF UNLOADING AREA TYPICAL ARRANGEMENTS
10'-0" [3050mm]
MIN. PLATFORM Ambulance Entrance Details
# NTS
SD001000-03.DWG
2'-6" [860mm] NOTES:
[3660mm]
MIN. CLEAR @
9'-6" NOTE #2
PLATFORM
12'-0"
[3960mm]
[2900mm]
VEHICLE
3. THIS DIMENSION IS A MINIMUM RECOMMENDATION.
13'-0" THE COVERED AREA SHOULD BE DESIGNED IN
RESPONSE TO THE SPECIFIC CONDITIONS OF
ENTRANCE DETAILS
PLATFORM
EACH PROJECT: CLIMATE, ORIENTATION, SITE,
WHEEL ETC.
STOP
WITH ENCLOSURE
OF WALL
GIVEN TO INCREASED CLEARANCE TO ALLOW FOR
14'-0" [4265mm]
SECTION
SCALE : NONE
NOTE #3
10'-0" [3050mm]
PLATFORM
MIN.
WHEEL STOP
RADIANT
AMBULANCE
ENTRANCE
10'-0" MIN.
MANUAL
S
[3050mm]
CONTROL
7'-0" MIN.
[2130mm]
THERMOSTAT STRETCHER AREA
VEHICLE DETECTOR
LOOP IN PAVEMENT
FAN SWITCH
PLAN
4'-0"
SD010000-02.DWG
[1219mm]
WHITE
BLUE OUTLINE
WITH WHITE
ZERO
in
INTERIOR
BLUE
[51mm]
BRACING SEE
ON SAFETY
2"
JOINT BRACING CONSTRUCTION
SIGN DETAIL
01010-1
[51mm]
2"
[914mm]
THIS PROJECT
3'-0"
[51mm]
HAS WORKED 0 0 0 DAYS
SCALE : NONE
THE LIFE YOU SAVE MAY BE YOUR OWN
[44mm]
1 3/4"
CONTRACTOR'S NAME
[102mm]
4"
4"x4" [102x102mm]
POST IF SIGN IS
VARIES
INSTALLED ON GRADE
FIN. GRADE
[915mm]
3'-0"
ELEVATION
SAFETY SIGN
# NTS
4"x4"
[102x102mm]
NEWEL POST
6 EQUAL SPACES
EACH LANDING
3.9" [99mm]
APART (REJECT 4"
DIA. SPHERE)
1 1/2" ± 1/16"
[38mm ± 2mm]
[864mm]
2'-10"
1 1/2" O.D.
[38mm]
THRU-BOLT OR
EXPANSION BOLT
TO WALL
*
12"
[300mm] 1 1/2" ± 1/16"
[38mm ± 2mm]
1 1/2" [38mm]
O.D. PIPE
[864mm]
2'-10"
1/4"
TREAD
[6mm]
+ 12"
[864mm]
2'-10"
[305mm]
PLAN VIEW
SCALE : NONE
ELEVATION
METAL CHAIN(S), SNAP
HOOKS BARS, ARE V V.
30
SPECIAL CLAMP °-
45
BOLTS °
SPECIAL CLAMP
BOLT
VARIES AS
SHIMS
.
REQ'D.
[83mm]
COIL SPRINGS
METAL PLATE
FIN. CEILING
SPECIAL CLAMP BOLT
CEILING WALL EDGE ANGLES
EYE BOLT
SCALE : NONE
CUT HORIZONTAL
FASTENER FROM
STUD
AT 16" [406mm] OR
24" [610mm] O.C.
ISOMETRIC
WALL FINISH
GENERAL NOTES:
1. CONTRACTOR SHALL
COORDINATE LOCATIONS OF
HORIZONTAL FASTENERS.
PLAN
SCALE : NONE
[127mm]
FIN. WALL
RUBBER MOLDING FILLER RUBBER
5"
MOLDING
S.S. TOP & BACKSPLASH
FILLER
ANCHORAGE
METAL STD. DETAIL
LOCKS PARTITION 055000-02
[914mm]
3'-0"
1'-10"
[102mm]
[559mm]
4"
HINGED FLUSH FIN. 3"
METAL DOORS FLOOR [76mm]
ADJUSTABLE METAL SHELF
ELEVATION SECTION
DECK MOUNTED
18"x16"x6 1/2" S.S. SINK
SWING SPOUT
[457x406x165mm]
FAUCET
4'-0"
[1219mm]
PLAN
SCALE : NONE
[762mm]
METAL
2'-6"
SLIDING SHELVES
1'-4"±
DOORS
DUPLEX [406mm]
RECEPTACLE
[533mm]
PANEL S.S. SPLASH BACK &
SWING PER STD.
S.S. COUNTER
1'-9"
END
SPOUT DETAIL
MICROWAVE TOP
FAUCET ADJ. METAL SHELF 055000-02
SHELVES SLIDING
[127mm]
DOORS
2" MAX.
[305mm]
1'-0"
KITCHEN
[51mm]
5"
GARBAGE
[914mm]
DISPOSAL
3'-0"
22G/B UNIT
[102mm]
4"
HINGED
RESIL. BASE
FLUSH [559mm]
OVER METAL
METAL
BASE
DOOR
SCALE : NONE
4'-0"± 3"
[1219mm] FINISHED [76mm]
FLOOR
ELEVATION SECTION
6'-0"
[1829mm]
3'-0" 3'-0" FINISHED
GENERAL NOTES:
WALL
[914mm] [914mm] 1. THE CONTRACTOR SHALL SUBMIT SHOP
DRAWINGS FOR APPROVAL.
[559mm]
2. MICROWAVE SHALL BE FURNISHED AND
1'-10"
INSTALLED BY VA MEDICAL CENTER.
PIPE SLEEVE
FIRESTOP DRYWALL PARTITION
WHERE SPECIFIED
MATERIAL
1"
6"
PARTITION SUPPORT
FLOOR
[25mm]
[150mm]
WELD
6" 6"
SCALE : NONE
[150mm] [150mm]
1/4" [6.4mm]∅
6"
ANCHOR ROD FOR PARTITION OR CHASE PENETRATION
NEW CONSTRUCTION
[150mm]
FIRESTOP MATERIAL
SD078400-01.DWG
[229mm]
9"
9" 9"
M
[1067mm]
[229mm] 2 4 [229mm] 6 8
3'-6"
2
MUNTINS
100 IN MAX.
2
AS REQ'D.
[.064m ],
4"x25"
[102x635mm]
T.A.
T.A. OR W/F
OR
LOUVER SIZE 1 3 W/F 5 7
[305mm]
AS REQ'D. 'A' LABEL 'B' LABEL
12" 12"
[305mm] 8"x10" [203x254mm]
LEAD GLASS IF
9" 9" 9"
REQ'D. (DR. 15)
[1067mm]
2
100 IN MAX. SHELF RAY PROOF
[.064m ],
2
L. IF REQ'D.
[1524mm]
4"x25" (DR. 15)
5'-0"
[102x635mm]
'F' GLASS
[229mm] [178mm]
9 11 13 15/17
[457mm]
7"
'B'
1'-6"
'C' LABEL DUTCH DOOR
LEAD LINED
2 LABEL
2
1296 IN [.84m ] MAX. EACH
LEAF 4"x25" [102x635mm]
'F' GLASS
9"
9" MIN. 9" MIN.
20 24 [229mm] 26 [229mm]
LOUVERS
[1524mm]
5'-0"
AS REQ'D.
[305mm]
19 22 23 25
SOUND DETENTION
12"
30 36 [229mm] 38 [229mm]
40 42
COMBINATION T.A.
LOCK & VIEWER
[229mm]
A
HANDLE
9"
[610mm]
2'-0"
[1270mm]
SECURITY SECURITY 37
VAULT DOOR DOOR SECURITY INTEGRATED INTEGRATED
4'-2"
SCALE : NONE
NOTES:
1. ALL DOORS SHALL BE FLUSH - 1 3/4" [44mm] THICK UNLESS NOTED OTHERWISE.
2. TOP & SIDE RAILS SHALL BE 9" [229mm] MIN. BOTTOM RAILS SHALL BE 12" MIN. [305mm].
3. DOOR TYPES 7, 8, & 9 SHALL NOT BE USED FOR OPPOSING DOORS.
SCALE : NONE
EQ
LATH & PLASTER DOUBLE STUDS FOR SUPPORTING B 1/2" SEE
NOTE 1
CONC. BACKER BOARD. [13mm]
D
PROVIDE CONTINUOUS BRACING WHEN STUDS
[152mm]
6" MAX.
1/2"
EQ.
EXCEED 10'-0" [3048mm] & ARE FINISHED BOTH [13mm]
EQ
SIDES
CONST.
CRIPPLE STUD DO
VARIES
VARIES
NOT ANCHOR TO
BEARING STUD
DETAIL D SEE DOOR
EQ.
SCHEDULE
MET. DOOR
FRAME
GYPSUM
WALLBD. SHIM AS
PANELS
REQ'D.
CONTROL
DETAIL C
JOINT
ELEVATION AT DOOR FRAME
1/2" MIN. ST
U
[13mm] WI D
3/4" MIN.
DT
H
CE
PROVIDE
[19mm]
[13mm]
FA
SOUND 16
3/
1/2"
M E
DEADENING
RA S ]
WHERE
F
I NU 5mm
JA M [
REQ'D. MB
MI D
NU EPT
S H
[5 3/1
mm 6"
m] m]
3/4" MIN.
]
SECTION B
3m
ISOMETRIC OF CONSTR. JT. [1 [16m
[19mm]
N.
MI MAX. FAC 6
E
"
12 /8" ME 3/1
METAL
DOOR
ST 5 FRA US m]
FRAME N m
SANITARY WI D
U
MI [5
METAL DT
3/4" MIN.
STOP H
ANCHOR CLIP
[19mm]
JAMB
DOUBLE SHIM AS JAMB ANCHORS
ANCHOR
STUDS REQ'D. (FURNISHED WITH FRAME)
SECTION A DETAIL C DETAIL D
SCALE : NONE
SD081113-02.DWG
1 1/2"
CAULK ALL
2 1/2"MIN. AROUND
[64mm] 1/2" NOM. CMU 3/4"
[13mm] THIN SET [19mm]
[6mm]
1/4"±
1/4"
CONCRETE SETTING
[6mm] BED
C
DOOR FRAMES
FACED WITH GWB PLASTER WITH
TILE
OUT LATH PLASTER
CERAMIC TILE CEMENT
ON METAL
C METAL BACKER
SCALE : NONE
AROUND
NOTE: SHOWING THE SWING STANDARD
OF DOUBLE EGRESS DOORS. GROUT STANDARD ADJUSTABLE
JAMB ANCHORS STANDARD FRAME FRAME ANCHOR
FRAME FOR
TILE FINISH MASONRY BLOCK PLASTERED
DRYWALL
CAULK ALL
FRAME WHERE 1/4" TROWEL CUT
AROUND
2"
DOOR STOP
DRYWALL FINISH [5mm] AT FRAME
GAGE AS
IS REQUIRED EDGES
(BEYOND) SPECIFIED
ADJUSTABLE
ANCHOR ANCHOR
DOOR
[16mm]
5/8"
GROUT STANDARD
1 15/16" VARIES VARIES
STANDARD
FRAME
HEAD C FRAME
[49mm] METAL STUD AND EXPOSED MASONRY OR BRICK
(DOOR SIDE) PLASTER FINISH
SECTIONS DOUBLE EGRESS DOORS STANDARD DOOR FRAME FRAMES WITH METAL STUD AND PLASTER PARTITIONS FRAMES IN MASONRY PARTITION
*** FRAME WIDTH FOR NOMINAL MASONRY
WELD
2"
[51mm]
PROVIDE JAMB
REINFORCING FOR
HINGES OR PIVOTS
GROUT
FRAME MUST BE AT
FRAME
LEAST TWO PIECE TO FRAME MADE
SCALE : NONE
INSTALL OVER ANGLE FROM STOCK 1-15/16"
3/8"
FRAME.
[10mm]
1/8" [49mm]
LINED DOOR
FASTENED TO SLAB INSIDE FACE OF
GENERAL NOTES:
3. LEAD IS NOT REQUIRED IN THE DOOR HEAD WHEN IT IS ONLY REQUIRED IN WALLS TO 7'-0"
[2134mm] HEIGHT.
SD081113-03.DWG
[19mm]
3/4"
GLAZING
REMOVABE STOP
[50mm]
2"
[16mm] SECTION A
5/8"
GLAZING
REMOVABE STOP
CMU OR GWB ON
METAL STUDS
1/2" 1/2"
[50mm]
[12mm] [12mm]
2"
VARIES
SECTION B
6'-0" [1830mm]
SEE SPECIFICATION
FOR GLAZING
DOOR FRAME
ALIGN WITH
A
[1015mm]
B
3'-4"
ELEVATION
GENERAL NOTES:
1. SILL HEIGHT FOR OBSERVATION WINDOWS IN GROUP THERAPY CAN BE 24" (600mm).
2. PROVIDE HEADER IN METAL STUD FRAMING & LINTEL AT MASONRY.
SCALE : NONE
HEAD VARIES
HEIGHTS NOTE #2 [610mm]
4'-4" [1321mm]
4'-0" [1219mm]
[405mm]
1'-4"
OPENING IN
JAMB FOR
A A
VOICE
TRANSMISSION
B CLASS III
BULLET
TO FIN FLR
RESISTIVE
1'-4" SECTION A (HEAD SIMILAR) GLASS
[864mm]
[406mm]
2'-10"
[152mm]
8"
[76mm]
B 8"
4 1/2" 4 1/2"
3"
6"
[203mm] [203mm] [114mm] [114mm]
3'-0"
[914mm]
ELEVATION
CAULK
PERIMETER METAL SHELF
& DEAL TRAY
SEE GENERAL
NOTE 1
SECTION B
GENERAL NOTES:
1. 4" [102mm] OR 6" [152mm] SOLID CMU WALL w/ GYP. WALLBOARD BOTH SIDES.
MASONRY WALL IS TO EXTEND TO CEILING, ABOVE CEILING EITHER A MASONRY OR GYPSUM
WALLBOARD PARTITION MUST EXTEND TO UNDERSIDE OF SLAB ABOVE AROUND ENTIRE
INTERIOR PHARMACY WALL. WHERE MASONRY CONSTRUCTION IS NOT FEASIBLE, PLASTIC OR
LAMINATED GLASS PRODUCTS WHICH PROVIDE THE ACCEPTABLE LEVEL OF PROTECTION MAY
BE USED.
SCALE : NONE
[51mm]
ANCHOR
2" MIN.
CONCRETE OR
BOLTS
SOLID
MASONRY
RAISED
3'-0" EDGE OF LETTERS
[914mm] SEAL
OF VE T E RA
NT NS
E
M
GENERAL NOTES:
A
RT
FF
DE PA
A I RS
IC
E
E
SEALS, EXTERIOR
# NTS
SCALE : NONE
5/16" [8mm]
[64mm]
2 1/2"
TOGGLE BOLT,
[64mm]
2 1/2"
SEAL
EXPANSION BOLT
OR APPROPRIATE
[2083mm]
ANCHORAGE.
[914mm]
36"
LETTERING
6'-10"
ROSETTE WITH
THREADED PIN
DETAIL OF FASTENING
DEDICATION PLAQUE
# NTS
SCALE : NONE
M
OTHER MATERIAL.
A
T
F
PA R
DE
I RS
SAME AS ABOVE
A
PROFILE OF
C
SEAL
I
UN
R
IT
NOTES:
1. MATERIAL:
BRONZE: FEDERAL SPECIFICATION QQ-C-535B, COMPOSITION 2.
2. WORKMANSHIP:
CASTINGS SHALL BE OF UNIFORM QUALITY AND CONDITION, FREE FROM INJURIOUS
BLOWHOLES AND POROSITY, CRACKS AND OTHER DEFECTS AND NOT WARPED OR
DISTORTED, WELL FINISHED, FREE FROM BURRS, SHARP EDGES, SCRATCHES AND
DEFECTS THAT MAY AFFECT APPEARANCE OR SERVICEABILITY. CASTINGS SHALL NOT
BE REPAIRED, PLUGGED, WELDED, OR BURNED.
3. FINISH:
FINISH TO BE DETAILED, HAND CHASED FOR TRUE ALIGNMENT, FILED, BELT
POLISHED SIDES GROUND SMOOTH, RAISED SURFACES AND BORDERS, SUCH AS
ALL RAISED PORTIONS OF SEAL, EAGLE, SHIELD, LETTERING, ROPE BORDER ETC.,
TO BE POLISHED AND BUFFED TO A BRIGHT SATIN FINISH, BACKGROUND
TEXTURES TO BE REVERSE MEDIUM PEBBLE BACKGROUND, FINE PEBBLE
BACKGROUND, MOSS AS CAST, AS INDICATED.
4. COATING:
BRONZE: CHEMICALLY OXIDIZE TO A STATUARY MEDIUM COLOR AND FINISH WITH
ONE COAT OF CLEAR PROTECTIVE EXTERIOR METAL LACQUER.
5. FASTENERS:
CORROSION RESISTING METAL COMPATIBLE WITH MATERIAL OF CASTING.
SCALE : NONE
[610mm]
1'-0" 2 1/2"
[305mm] [64mm]
2 1/2"
[64mm]
1"
CENTERLINE OF PLAQUE,
1/4"
[6mm]
[25mm]
1 1/2"
[38mm]
V.A. SEAL NAMES AND TITLES
OF FASTENERS (TYP.
8"
OF ALL CORNERS)
OF VE T E RA
ROPE BORDER
[203mm]
NT NS
E
A
5 1/4"
TM
[133mm]
R
FF
A
PA
MOSS AS
CAST FINISH
DE
I RS
A
1/4" 1/4"
IC
UN
[6mm] [6mm]
R
1" 1"
5 1/4"
IT
[133mm]
[25mm]
E [25mm]
D M
A
SATIN BRIGHT FACE ON
ST
ALL SIDES OF LETTERING
AT E S OF
TOP OF
1 3/4"
[44mm]
TOP OF LETTERING
LETTERING
7/8"
NAME
[22mm] L 1/2"
[13mm]
5/8"
PRESIDENT OF THE UNITED STATES
[16mm] P 5/8"
[16mm]
5/8"
NAME
[16mm]
3'-0"
D 3/8"
1/2" [10mm]
SECRETARY OF VETERANS AFFAIRS
[13mm] 0
5/8"
[914mm] (SEE NOTE 4)
[16mm]
5/8"
NAME
[16mm] H 3/8"
1/2" [10mm]
[13mm] C UNDER SECRETARY (SEE NOTE 1)
1/2"
[13mm]
5/8"
NAME
REVERSE MEDIUM [16mm] A 3/8"
1/4"
[6mm]
[25mm]
SCALE : NONE
2. SOME PLAQUES WILL NOT INCLUDE ASSOCIATE CHIEF MEDICAL DIRECTOR FOR OFM
CONSTRUCTION MANAGEMENT. ADJUST SPACING BETWEEN LINES OF TEXT AND
INCREASE DIMENSION BELOW LAST LINE TO ACCOMMODATE THE NUMBER OF LINES
OF TEXT.
4. DEDICATION PLAQUES FOR SATELLITE OUTPATIENT CLINICS WILL OMIT THE SENIOR
RESIDENT ENGINEER, ARCHITECT/ENGINEER, AND GENERAL CONTRACTOR. THE
OVERALL HEIGHT OF THE PLAQUE SHALL BE 30 INCHES [762mm].
5. MATERIAL: THE PLAQUE SHALL BE CAST OF A LEAD FREE TIN BRONZE, SUCH AS
C90300 (NAVY "G" BRONZE) OR SIMILAR ALLOY APPROVED BY V.A.
6. WORKMANSHIP: CASTINGS SHALL BE OF UNIFORM QUALITY AND CONDITION, FREE
FROM INJURIOUS BLOW HOLES AND POROSITY, CRACKS, AND OTHER DEFECTS AND
NOT WARPED OR DISTORTED, WELL FINISHED, FREE FROM BURRS, SHARP EDGES,
SCRATCHES, AND DEFECTS THAT MAY AFFECT APPEARANCE OR SERVICE-ABILITY.
CASTINGS SHALL NOT BE REPAIRED, PLUGGED, WELDED, OR BURNED.
7. FINISH: FINISH TO BE DETAILED, HAND CHASED FOR TRUE ALIGNMENT FILED, BELT
POLISHED SIDES GROUND SMOOTH, RAISED SURFACES AND BORDERS TO BE
POLISHED AND BUFFED TO A BRIGHT SATIN FINISH, BACKGROUND TEXTURES TO
BE REVERSE MEDIUM PEBBLE BACKGROUND, FINE PEBBLE BACKGROUND, MOSS
AS CAST, AS INDICATED.
10. TEXT: INFORMATION FOR FILLING OUT PLAQUE WILL BE PROVIDED BY THE
DEPARTMENT OF VETERANS AFFAIRS AT TIME OF ORDER FOR INDIVIDUAL PLAQUE.
PRIOR TO CASTING, RUBBINGS WILL BE PROVIDED TO VA FOR REVIEW.
11. THE USE OF METRIC DIMENSIONING IS ALLOWED, PROVIDED THAT THE METRIC
EQUIVALENT IS COMPARABLE AND MEETS FEDERAL STANDARDS FOR CONVERSION.
SCALE : NONE
[1470mm]
TOP OF TOILET
PARTITION. SEE
58"
CEILING MOUNTED
MFGR'S DETAIL TOILET PARTITIONS
LATERALLY BRACE
SUSPENDED CHANNEL TO
WALL OR STRUCTURE
[300mm]
ABOVE
12"
METAL SUSPENDED CEILING
CLIP PER FINISH SCHEDULE.
2" MIN.
[50mm]
STALL DETAILS
ELEVATION
WHERE SOFFIT 3/8" [10mm] STUD BOLT
SCALE : NONE
C
L C
L
[300mm]
[1500mm]
MIN PG-18-13
72" [1800mm]
[1065mm]
12"
60"
18"
42"
NOTES: [450mm] 1" 1"
1" [25mm] [25mm] [25mm]
A/E SHALL LOCATE GRAB BARS AND TOILET 42" 36"
ACCESSORIES IN ACCORDANCE WITH CHAPTER 6 OF
THE ADA-ABA ACCESSIBILITY STANDARD. 66" [1680mm] [1050mm] [900mm]
MIN PG-18-13 FRONT TRANSFER STANDARD
VA BARRIER FREE DESIGN GUIDE PG-18-13
SPECIFIES LARGER WHEELCHAIR ACCESSIBLE STALLS
34" 34"
[864mm] [864mm]
PLAN
36" MIN.
[900mm]
[1525mm]
ROOM ENTRANCE SCREEN
60"
48" 42"
[1200mm] [1065mm]
PLAN A
[900mm]
36" MIN.
METAL TOILET
PARTITION. SEE
STANDARD DETAIL
54" MIN.
CORRIDOR
10 21 13-1
[1350mm]
PLAN B
9'-0" [2700mm]
VARIES
PILASTER
58"
METAL SCREEN
[300mm]
ELEVATION A
SCALE : NONE
[127mm]
5" MAX.
TOGGLE BOLT
8" [203mm]
CONT. RETAINER
NEOPRENE CUSHION
AT EACH FASTENING
BASE
FINISHED FLOOR
SECTION
RESILIENT CONTACT
SURFACE BUMPER
AS REQ'D.
LENGTH
ANCHORAGE SHALL BE
LOCATED TO MISS STUDS
WALL GUARDS
# NTS
SCALE : NONE
SD102800-01.DWG
NOTES:
6" 18"
VA BARRIER FREE DESIGN GUIDE PG-18-13 SPECIFIES
[150mm] [450mm]
VACUUM BREAKER
MINIMUM 48"x48" [1200x1200mm] ROLL-IN TYPE SHOWER
FOR PATIENT BATHING. 90% OF INDIVIDUAL SHOWERS IN
CURTAIN ROD MEDICAL-SURGICAL NURSING UNITS (MSN) AND NURSING
HOME CARE UNITS (NHCU) SHOULD BE THIS SIZE TO
4" FACILITATE USE OF WHEELCHAIRS, SHOWER SEATS, AND
3" [75mm]
GRAB BAR
(SCI ONLY) [750x1500mm] ROLL-IN LITTER SHOWERS MAY BE USED
6'-8" [2000mm]
FOR MENTAL HEALTH (MH&B) UNITS, DOMICILIARY, AND
[450mm]
STAFF FACILITIES. REFER TO CHAPTER 6 OF THE ADA-ABA
18"
SOAP HOLDER
33" [825mm]
A/E SHALL CAREFULLY COORDINATE FLOOR SLOPES AND
[150mm] 36" [900mm] CONTROLS DRAIN LOCATIONS TO CONTAIN AND CONTROL WATER FROM
ACCESSIBLE
SHOWER ROLL-IN
48" [1200mm] MIN.
SCALE :
CEILING
48" [1200mm]
36" [900mm] [150mm]
ROD A
MIN. TO NEAREST
OR OBSTRUCTION
SLOPE C
8" (200mm) STUDS
ENTIRE WITH BACK TO BACK
FLOOR AS SHOWER HEADS
SHOWN
VERTICAL GRAB BAR
PLAN
SD102800-02.DWG
[2134mm]
TO BOT PLATE w/ 3/16" [5mm] WELD
12"x4"x1/4"
4" [102mm] METAL STUDS [305x102x6mm] STL
PLATE [TOP & BOTTOM]
[1067mm]
SUPPORT STD
5/8" [16mm]
3'-6"
L
C
DTL 05500-2
[457mm]
EXP. BOLTS
FOR CONC.
18"
18"
CERAMIC TILE
36"
[914mm]
1 1/2" METAL SLEEVE
[51mm]
2'-2"
5/8" [16mm] UP-SWING G.B.
MOUNTING BRACKET
[660mm]
2"
G.W.B.
PLAN SHOWING THE STEEL TUBE & PLATE PLAN OF TOILET ROOM SHOWING RELATIONSHIP OF FIXTURES
FOR ANCHORING THE UP-SWING GRAB BAR
GRAB BAR
12"x4"x1/4" [305x102x6mm] 3/8"x6" [10x152mm]
STEEL PLATE 5/8" [16mm]∅ PLATE, 2" [51mm] WIDE
SCALE : NONE
L m] GRAB BAR SCH. 40
[222mm]
8-3/4"
[457mm] [400mm]
MOUNTING BRACKET
6 3/4"
3 3/4"
[171mm] (4) 3/8" [10mm]∅
[95mm] BOLTS
2'-2"±
2 1/4" 1'-0" 3 3/4"
2'-9" [840mm]
2'-9" [838mm]
[660mm]
[57mm] [305mm] [95mm] TOILET PAPER
TO FIN. FL.
TO FIN. FL.
HOLDER
HINGE PIN
ELEVATION SHOWING POSITION OF UP-SWINGING GRAB BAR SIDE ELEVATION OF UP-SWINGING GRAB BAR
GENERAL NOTES:
S.S. SHELF
T-45 SEE
NOTE #1
TILE WAINSCOT
[1200mm]
SOAP DISP.
[1015mm]
48"
(V.V.)
[865mm]
34" MAX.
40"
[675mm]
27" MIN.
SEE NOTE #2
OFFSET
WASTE
NOTE #3
SCALE : NONE
SHELF AS REQ'D.
TO RIM OF LAV.
TYPE 45C
ELEVATION
FOR TYPE 45
1'-2" [356mm]
SHELF TYPES 45 & 45C
FINISHED
WALL
10" 1"
[254mm] [25mm]
CLOSED
2"
S.S.
FRONT 1/4" [6mm]
SHELF
CLOSED FRONT EDGE S.S. EXP. OR
[51mm]
[914mm] O.C.
MAX. (3) #10 S.S. F.H.
M.S. AT EACH
BRACKET
TOP OF COUNTER
2'-0" [610mm] TO
SHELF TYPE 44
GENERAL NOTES:
1. SEE ARCH. PLANS FOR LOCATION OF STAINLESS STEEL SHELVES TYPES 44, 45 & 45C.
2. TOP OF SHELF TYPE 45C SHALL BE LOCATED 1'-5" [432mm] ABOVE RIM OF UTILITY SINK.
3. WHERE SHELF TYPE 45C OCCURS ABOVE FLUSHING RIM SERVICE SINK IT SHALL CLEAR FITTING
SCALE : NONE
TURNBUCKLE (TYP)
[90mm]
(TYP)
UNIT COOLER
SCALE : NONE
1. UNIT COOLER FAN(S) SHALL RUN CONTINUOUSLY, EXCEPT WHEN IT IS TURNED "OFF"
BY A SWITCH MOUNTED ON THE UNIT COOLER. THIS SAME SWITCH SHALL ALSO
DE-ENERGIZE THE LIQUID-LINE SOLENOID VALVE WHEN THE UNIT IS IN THE "OFF"
POSITION..
A. DEFROST TYPE UNIT COOLER WITH HEATING ELEMENTS FOR EVAPORATOR COIL,
DRAIN PAN AND DRAIN PIPING WITHIN THE LOW TEMPERATURE ROOM. DEFROST
CYCLE SHALL BE AUTOMATICALLY CONTROLLED BY AN ELECTRIC CLOCK AND
SHALL INCLUDE A SAFETY THERMOSTAT IN THE CONTROL CIRCUIT TO PREVENT
OVERHEATING THE EVAPORATOR COIL.
B. THE AUTOMATIC TIMER FOR ELECTRIC DEFROST SHALL ALSO DE-ENERGIZE THE
SOLENOID VALVE IN THE LIQUID REFRIGERANT LINE SERVING THE UNIT COOLER
AND SHALL STOP THE UNIT COOLER FAN(S) DURING THE DEFROST CYCLE.
6. PROVIDE ADDITIONAL TEMPERATURE TRANSMITTER THAT SENDS HIGH TEMPERATURE
ALARM INDICATION TO ECC.
SCALE : NONE
1. UNIT COOLER FAN(S) SHALL RUN CONTINUOUSLY, EXCEPT WHEN IT IS TURNED "OFF"
BY A SWITCH MOUNTED ON THE UNIT COOLER. THIS SAME SWITCH SHALL ALSO
DE-ENERGIZE THE LIQUID-LINE SOLENOID VALVE WHEN THE UNIT IS IN THE "OFF"
POSITION.
A. DEFROST TYPE UNIT COOLER WITH HEATING ELEMENTS FOR EVAPORATOR COIL,
DRAIN PAN AND DRAIN PIPING WITHIN THE LOW TEMPERATURE ROOM. DEFROST
CYCLE SHALL BE AUTOMATICALLY CONTROLLED BY AN ELECTRIC CLOCK AND
SHALL INCLUDE A SAFETY THERMOSTAT IN THE CONTROL CIRCUIT TO PREVENT
OVERHEATING THE EVAPORATOR COIL.
B. THE AUTOMATIC TIMER FOR ELECTRIC DEFROST SHALL ALSO DE-ENERGIZE THE
SOLENOID VALVE IN THE LIQUID REFRIGERANT LINE SERVING THE UNIT COOLER
AND SHALL STOP THE UNIT COOLER FAN(S) DURING THE DEFROST CYCLE.
6. PROVIDE ADDITIONAL TEMPERATURE TRANSMITTER THAT SENDS HIGH TEMPERATURE
ALARM INDICATION TO ECC.
SCALE : NONE
HB
ACID RESISTANT/NON S
ROOF
-SPARKING UPBLAST FAN
PLENUM
INSULATE ALL
DRAIN
WATER PIPING.
SCALE : NONE
STATIC TIP
H3
HOOD
FILTER
* R STATUS
ALARM
G
NORMAL
LTCP
dPS
* MOUNT
GAGE IN
COVER
SCALE : NONE
FOR H3
HOOD ONLY
DETAIL TITLE / H3
LEGEND
MAGNEHELIC GAGE
NOTES:
1.HOOD EQUIPPED WITH INTEGRAL BYPASS, IE CONSTANT VOLUME
2.SEE STACK DETAIL
DESIGNERS NOTES:
1.SEE HVAC DESIGN MANUAL FOR ADDITIONAL REQUIREMENTS.
2.H-3 HOODS CAN BE GROUPED INTO A SINGLE EXHAUST FAN
SD115313-02.DWG
3.H-7 HOODS CAN BE GROUPED INTO A SINGLE EXHAUST FAN
VD
TO
GENERAL
EXHAUST
CEILING
THIMBLE
CONNECTION
FLOOR
BIOLOGICAL
SAFETY
CABINET
(BSC)
A1 OR A2
DESIGNER'S NOTES:
1. COORDINATE SIZE AND TYPE OF BIOLOGICAL SAFETY CABINET (BSC) WITH THE
ARCHITECTURAL EQUIPMENT DRAWINGS.
SCALE : NONE
AIR FLOW
CONTROL
VALVE
CEILING
TRANSITIONS
HEPA
FILTER
FURNISH
W/HOOD
CONNECT STAINLESS
STEEL DUCT TO HOOD
FLOOR
BIOLOGICAL
SAFETY
CABINET
(BSC)
B1 OR B2
DESIGNER'S NOTES:
1. COORDINATE SIZE AND TYPE OF BIOLOGICAL SAFETY CABINET (BSC) WITH THE
ARCHITECTURAL EQUIPMENT DRAWINGS.
SCALE : NONE
[1067mm]
3'-6"
ADJ. METAL 1'-10"
ANCHORAGE PER
SHELVES
[559mm] STD. DETAIL
05 50 00-02
TO FINISHED FLOOR
FINISHED WALL
3'-0"± [914mm]
5'-6" [1676mm]
UNITS TYP. SPACE FOR
PORTABLE LINEN
2'-0"± [610mm] SHELVING UNITS
UNITS WHERE REQ'D.
A
AVAILABLE SPACE
SEE PLANS
FINISHED
WALL
PLAN
SCALE : NONE
[279mm]
11"
PLASTER OR GYP.
[25mm]
WALL BD. COVER PLATE
1"
[76mm]
METAL GYP. WALL BD. OR S.S. HANGER
BACK EXPOSED MASONRY 2'-2" ROD METAL
3"
C C
[660mm]
[2286mm]
BACK
EQ. EQ. ALUM. OR
7'-6"
[1905mm]
6'-3"
S.S. MOULD 2'-2"
ANCHORAGE STD. [660mm]
PLASTIC LAMINATE ON DETAIL
[102mm]
4"
[914mm]
D D
3'-0"
ALUM. OR S.S.
RESIL. BASE OVER EDGING GUIDE
METAL BASE
FINISHED FLOOR
FINISHED
A B DRAWERS FLOOR
3"
SCALE : NONE
7/8" MAX.
[22mm]
ROUGH PLASTER, CEILING ROUGH PLASTER, GYP. WALL RUBBER BUTTON FINISHED
GYP. WALL BD. OR BD. OR EXPOSED MASONRY SILENCERS WALL
EXPOSED MASONRY 5/8" [16mm]
MIN. THICK SOUND METAL BACK
DEADEN FLUSH
METAL END SCRIBE
FINISHED WALL METAL DOOR
[660mm]
PLATE
2'-2"
SCRIBE PLATE SCRIBE PLATE AT DRAWER
LOCK METAL
TOP & SIDES
METAL BACK & END
1'-11 1/8"
RECESSED HAND INDICATE DOUBLE
[587mm]
[51mm]
DRESSER CLOTHES SLIDING FLUSH
GRIPS UNITS END TO END
CLOSET
METAL DOORS
2"
FINISHED WALL FINISHED WALL
FINISHED FLOOR
1/4" MIN. CLEARANCE 4'-0"±
[1219mm]
PLAN C ELEVATION OF
SLIDING DOORS
1 2 2
2. ONE TUBE 24" [610mm] LONG WITH PLASTIC
3 3 3 LENS
4 4 4
3. FLUORESCENT LIGHT
[2032mm]
[2032mm]
6'-8"
6'-8"
6'-8"
7 7 7 5. ADJUSTABLE METAL SHELVES
11 10 11 10 11 10
7. TIERED MEDICINE SHELF
8. SWING FAUCET
9. DUPLEX OUTLET
14 14 14
10 SINK
SIZES 1, 2, 3 & 4
11. DRAWER WITH LOCK
SCALE : NONE
21
[1829mm] LONG, OR ONE TUBE 48" [1219mm]
30°
MIN.
22 LONG WITH PLASTIC LENS.
17 9" IN. [229mm]
12" MAX. [305mm] 16. CUP DISPENSER.
.
15
20
3 17. HOOD
4 25
18. REFRIGERATOR 3.5 CU. FT. MIN.
5
6 16
19. MEDICINE CARD RACK.
19
5
[2032mm]
7 23
MEET PROPER RECOMMENDED REQUIREMENTS.
9 8
8
21. SLOPING METAL TOP OR FURRED-IN CABINET
11 10 (TO BE DETERMINED BY ARCH).
10
22. HOOD FOR DOOR. MECHANISM IN HOOD MUST
BE ACCESSIBLE FOR REPAIRS. NOTE: DOOR
18 13
MUST COIL UP IN HOOD.
3" 25
14 23. ROLL-UP DOOR ALUM. DOOR WITH LOCKING
[76mm]
HANDLE (DOOR DROPS TO COUNTER TOP IN
14
DOWN POSITION).
24. FACE OF WALL.
Windows (mm)
1 Radiographic Fluoroscopic Room 1.5mm (3mm for 1.5 mm (3 mm None on 100 None
2100 mm (7")
(Ceiling Mounted X-Ray)
on Partition on for Door to Dark mm (min.)
Special Procedures Diagnostic and Tele-Fluoroscopy Dark Room Side) Room Normal Weight
Concrete
(Ceiling Mounted X-Ray)
Radiography and Fluoroscopy on Partition on on Partition on Door to Dark Room (min.) Normal
NONE
General Treatment Operatories
SCALE :
6
Dental X-Ray Room (Portable 50/65 KVP) None None None None None
7 Fluoroscopic Rooms, Vertical or Tilt Type, 1.5 mm (No Control 1.5 mm None on 100 mm None
2100 mm (7")
Gastroenterology (No Radiography) Booth Required) (min.) Normal
Weight Concrete
8 Operating Room Including Animal Operating None None None None None
9 Cardiac Catheterization in cardiopulmonary 1.5mm (3mm for 1.5 mm (3 mm None on 100 mm None
2100 mm (7")
Clinic (Fixed Equipment) on Partition on for Door to Dark (min.) Normal
Operating Room (Fixed Equipment) Dark Room Side) Room Weight Concrete
GENERAL NOTES:
GENERAL NOTES:
SCALE : NONE
12" [305mm]
.
5'-4"
[1220mm]
4'-0"
POWER
10" [250mm]
.
SUPPLY
[1625mm]
1'-5" [430mm] LOCATION MAIN BREAKER 5/8" (16mm) GWB 4" [100mm] OR RACEWAY 1.50 mm LEAD
.
1'
ON VERTICAL LINED PARTITION
6" [150mm]
-6
[2950mm]
10" [250mm]
[4
1" [25mm] SPACE
.
"
135° RACEWAY METAL STUDS
.
9'-8"
35
MI
12" [305mm]
N.
mm
COVER
]
3
'
VERTICAL
[1
-
PLATE
SECTION D-D
6
"
0
RACEWAY 7'-0" HIGH
6m
[2130mm]
m]
[1525mm]
[6100mm]
PARTITION
20'-0"
6" [150mm]
5'-0"
OFFICE OR 2'-6" X-RAY ROOM
METAL STUDS
(R-F) ROOM
STUD WALL
6'-3" D D
[1930mm]
FLOOR
VERTICAL RACEWAY RACEWAY 1" [25mm] SPACE 1.50 mm LEAD
NONE
LINED PARTITION
RACEWAY ABOVE CEILING
10" [250mm]
.
SCALE :
.
E METAL STUD
12" [305mm] WALL
.
E 5/8" (16mm)
8'-6" 10" GWB
[2590mm] [250mm]
3 1/2" [90mm] VERTICAL RACEWAY
16'-0"
[4880mm]
STUD WALL
CORRIDOR SIDE 5/8" (15mm) GYPSUM
SECTION F-F
SD134900-04.DWG
7'-0" HIGH PARTITION
AT CONTROL BELOW
NONE
CEILING SUPPORT
GRID
ATTACH CLNG.
SCALE :
EDGE ANGLE
A TO CHANNELS
OR K-SERIES CHANNELS
SERIES WITH OPTIONAL CEILING
CHANNELS TILE FLANGES
GENERAL NOTES:
PROVIDE SUSPENDED GRID OF STRUT CHANNELS TO SUPPORT X-RAY MACHINE RAILS. A/E
SHALL DESIGN SUPPORT SYSTEM TO SUIT BUILDING STRUCTURE. SUPPORT RAILS FROM
A
A
SCHEME 1 & 2
RACEWAY
NONE
DETAIL TITLE /
BUILDING SYSTEM (VA HBS) RWT-60 PARTITION X-RAY TABLE BASE
FIELD INSTALL VCT OVER 1/4" [5mm]
SCALE :
WHERE REQ'D. STEEL REMOVABLE COVER
12" WIDE COVER
1 1/2" PLATE FOR RACEWAY 1 1/2"
[40mm] [300mm] [40mm]
3 1/2"
[90mm]
LEAD LINING
5 1/2" IF REQ'D
12" 3 1/2" [90mm]
[140mm] 5"
CONC. FILL TOPPING
[305mm]
[225mm]
[125mm]
NOTE 2
5"
10"
NOTE 2
STRUCTURAL
[125mm]
FLOOR SLAB
10" 6"x6"x1/4" STEEL PLATE 1" [25mm] DIA. I.D. STL.
RACEWAY RACEWAY PIPE SLEEVE BONDED
[225mm] [150mm x 150mm x 6mm]
W/1mm LEAD & 5/8"
SECTION B SECTION C SECTION A [15mm] THRU BOLT.
GENERAL NOTES:
P1000 P1000
P2473
P5500
[124mm]
4-7/8"
P1001
5-1/16"
[127mm]
[127mm]
5-1/16"
NONE
DETAIL TITLE /
P1000 WITH ANCHORS
INSERTED IN CONCRETE
SLAB.
SCALE :
LAY-IN CEILING R/F ROOM SCHEME 1 P2346
P1000
25" [625mm]
APPROX.
A B