Sei sulla pagina 1di 132

t

ä
ä
rd/qf/09.04/2000

Michael Riedel

t
t

Transformatorenbau GmbH

i
i
Transformatorenbau GmbH

l
l

a
a
Produktion: www.querformat.info

u
u

Q
Q

r
r

ü
ü

f
f

w
w

o
o

h
h

-
-

w
w

o
o

n
n

K
K

s
s

a
a

d
d

n
n

e
e

b
b

Michael Riedel

a
a

2004

Transformatorenbau GmbH 2004

h
h

Max-Eyth-Straße 10 · D-74532 Ilshofen-Eckartshausen


Telefon (0 79 04) 7 04-0 · Fax (0 79 04) 7 04 50

r
r

www.riedel-trafobau.de · info@riedel-trafobau.de

i
i

W
W
t
ä
Michael Riedel

t
i
Transformatorenbau GmbH

l
a
u
Q
r
ü
f
w
o
h
-
2005
Introduction
w
o
n
K
s
a
d
n
e
b
a
h
r
i
W
allg_041014.qxd 14.10.2004 09:58 Seite 1

Introduction Customer information


In general
Regulations and directives
Technical explanations
Terms of sale and delivery

Product group Single-phase transformers Control transformers / stock range


Power transformers

A
Isolation transformers
Safety transformers
Miniaturized transformers
Universal control transformers
Anti-interference transformers with special screening
High-power transformers
Speed regulators
Portable transformers

Product group Three-phase transformers Speed regulators in V-circuit


Power transformers

B
Isolation transformers
Safety transformers
Dry-type transformers
Starter-transformers

Product group Single-phase D.C. power supplies Single-phase (rectifier) transformers


Single-phase compact rectifier transformers

C
Single-phase compact power packs, non-stabilized and stabilized
Single-phase switch power packs stabilized, primary- and secondary switched

Single-phase battery chargers Single-phase battery chargers

UPS D.C.-UPS-modules

Others Power supplies with back-up battery


Voltage monitoring modules

Product group Three-phase D.C. power supplies Three-phase compact rectifier transformers
Three-phase universal compact rectifier transformers

D
Three-phase compact rectifier transformers, covered
Three-phase compact rectifier transformers, in housing
Three-phase switch power packs stabilized, primary- and secondary switched

Three-phase battery chargers Three-phase battery chargers

UPS D.C.-UPS-modules

Product group Variable ratio ring transformers Single-phase variable ratio ring transformers
Three-phase variable ratio ring transformers

E
Motor drives
Accessories
Voltage stabilizers electro-motorial

Product group Chokes Single-phase line chokes


Single-phase twin-line chokes

F
Three-phase filter circuit chokes
Three-phase line chokes

Product group Other products Transformers for medical rooms


Housings

G
Inrush current limiters

1/1
allg_041014.qxd 14.10.2004 09:58 Seite 2

1/2
allg_041014.qxd 14.10.2004 09:58 Seite 1

How to get there:

Welcome at Riedel!

1/1
allg_041014.qxd 14.10.2004 09:58 Seite 2

In general
The stated technical explanations indicate many application areas besides also valid special and exceptional rules. The
following is intended as a short introduction into the complex subject.

CE mark
The council of the European Community (EC) has issued EC-directives basing on the founding contract of the Europe-
an Economy Community (EEC), in particular article 100. EC-directives serve to adapt legal and administrative rules in
the diverse European Union (EU) member states whenever differences in national rules cause commercial handicaps
or in any other way obstruct EU-interior market. The directives are to be translated into national law by respective natio-
nal legislative authorities within a given deadline. Manufacturers must CE mark their products to demonstrate confor-
mity once products fall within certain EC-directives. Concerned are all products contained in the 'new conception' di-
rectives (decree May 8, 1985), which state requirements for technical condition.

CE mark: Communautés Européennes

EC-directives are obligatory legal rules within the European Union and meeting these requirements are precondition
for any product sale in Europe. The remaining world trade market is not affected. As soon as a product is CE marked, it
indicates its conformity with respective fundamental requirements of all relevant directives. The CE mark merely is a di-
rective conformity proof for supervisory authorities. Quite often it is misinterpreted as a 'quality symbol' though and the-
refore frequently requested, yet lacking any legal basis.
As such we refrain from printing the CE mark as a marketing tool in our catalogue and brochures. EC-directives must
be adhered to as a matter of course by all manufacturers or importers.
Although manufacturers must provide EC conformity declarations only for the supervisory authority (for at least 10
years counting from last delivery date) our customers may certainly request a respective copy.

The directive in question is stated in each respective product's EC conformity declaration. The most frequent directives
concerning our product spectrum are:
1. Low tension directive (73/23/EEC) for electric appliances in rated voltages between 50 VAC and 1000 VAC and between
75VDC and 1500VDC.
Title: Directive by council for adaptation of legal rules among member states pertaining electric appliances for applica-
tion within certain voltage limits 73/23/EEC, Feb. 19, 1973.

Just about all Riedel products fall within the scope of the low tension directive. Conformity with directive's protection re-
quirements for each electric appliance, device, each system and each equipment must be confirmed by the manufac-
turer via EC conformity declaration and product or packing must be marked with EC conformity mark CE.
2.EMC directive (89/336/EEC) for devices which can cause electromagnetic interference or of which operation can be
impaired by such interference.
Title: Directive by council for adaptation of legal rules among member states pertaining electromagnetic compatibility
89/336/EEC, May 03, 1989.

Legal basis:
On May 03, 1989, the council of the European Community (EC) issued an obligatory directive to adapt legal rules in its
member states. The Federal Republic of Germany has translated same into national law November 09, 1992 by virtue
of law about electromagnetic compatibility (EMVG). The settlement authority for mail and telecommunication (formerly
BAPT) and their branch offices have been appointed for it's enforcement (supervision).

1/2
allg_041014.qxd 14.10.2004 09:58 Seite 3

Definition, according to excerpt from article 1:


"Electromagnetic compatibility" is the ability of an apparatus, appliance or system, to operate satisfactory in an electro-
magnetic environment and not creating electromagnetic interference itself which would be unacceptable for any ap-
paratus, appliance or system present in this environment.

Norm scope, according to excerpt from article 2:


The directive is valid for equipment able to cause electromagnetic interference or of which operation can be impaired
by such interference.
Information:
"Equipment" (according to article 1) are all electrical and electronic apparatuses, appliances and systems containing
electrical and/or electronic components.

Principle of procedure:
As of Jan. 01, 1992 (transition time until Dec. 31, 1995) only such electrical and electronic equipment, system and appli-
ance may be traded with or put into operation in the European Union that meets EMC-protection requirements laid
down in the directive. Conformity with directive's protection requirements for each electric appliance, each system and
each equipment must be confirmed by the manufacturer via EC conformity declaration and the product must be mar-
ked with an EC conformity mark CE.

Components without obligatory mark:


The definition component within the meaning of EMC-directive is any element to be installed in equipment, yet in itself
not possessing a function and not destined to be used by ultimate customers. According to EMC-directive, article 1,
components are not equipment and therefore not touched by the directive.

Examples:
a. components (for pcb, units, switch cabinets), as integrated components not obligatory CE marked - for example re-
sistors, capacitors, inductivities, integrated circuits, chokes, transformers
b. components obligatory CE marked (incl. cabinet and protected against accidental contact), which are independent-
ly operable and/or for sale to ultimate customers - for example plug-in power supplies, battery chargers, personal
computers, test sets and meters, isolating transformers for construction sites or service, transformers for halogen
lamps

Norms
The norm scope concerning inductivities has simplified resp. will simplify.
The essential norms for the manufacture of dry-type transformers (safety and isolating transformers, formerly DIN VDE
0551 / EN 60742; control and power transformers, formerly DIN VDE 0550) have been integrated into the new norm
structure DIN VDE 0570 / EN 61558.
Special inductivities, for example transformers for switch power packs, are treated separately in the directive.
We adapt all concerned products within transition deadlines.
If not agreed otherwise, we manufacture in "uptodate technical standard" complying to norms as stated on each cata-
logue page on headline or complying to norms on overleaf pages.
Standard stock items can be delivered within transition deadlines in the norm valid at manufacturing date and applied by you
without problem.

1/3
allg_041014.qxd 14.10.2004 09:58 Seite 4

Norm references
DIN VDE 0100 DIN VDE 0532 part 6 (01.94) DIN EN 60999/VDE 0609 part 1 (12.00)
Erection of power installations with rated voltages Transformers and reactors - dry-type power trans- Connecting devices - safety requirements for
up to 1000V formers screw-type and screwless-type clamping units
EN 60289 / DIN VDE 0532 part 20 (05.94) for electrical copper conductors
DIN VDE 0100 part 410 (01.97) Reactors
Erection of power installations with rated voltages IEC 445
up to 1000V DIN VDE 0532 part 21 (03.82) DIN 42404
Protection against electric shock Transformers and reactors - Starting transfor- Terminal markings for transformers, safety trans-
mers and starting reaktors formers, variable transformers, small reactors
DIN VDE 0105 part 1 (10.97)
Operation of power installations; DIN VDE 0532 part 23 (08.94) IEC 947-7-1 (1989) EN 60947-7-1 (1991) /
general specifications Transformers and reactors - stationary trans- DIN VDE 0611 part 1 (08.92)
formers in traction systems Low-voltage switchgear and controlgear
DIN VDE 0106 part 100 (03.83) Part 7: ancillary equipment, terminal blocks for
Protection against electric shock; EN 60076-1 / DIN VDE 0532 part 101 (12.97) copper conductors
actuating members positioned close to parts Power transformers - general
liable to shock DIN VDE 0611 part 3 (05.00)
EN 60950 / DIN VDE 0805 (12.01) Modular terminal blocks for connection of copper
DIN VDE 0107 (10.94) Safety for equipment of the information technique conductors; protective conductor terminal blocks
Electrical installations in hospitals and locations for for copper conductors
medical use outside hospitals DIN VDE 0558 part 1 (07.87)
Semiconductors - converters DIN VDE 0635 (02.84)
DIN VDE 0108 part 1 (10.89) Low-voltage fuses -
Power installations and safety power supplies in EN 61558-1 / DIN VDE 0570 part 1 (07.98) D-fuses E 16 up to 25 A, 500 V;
communal facilities; general Safety of power transformers, power supply units D-fuses up to 100A, 750 V;
D-fuses up to 100A, 500 V
and similar - general requirements and tests
DIN VDE 0110 part 1 (04.97)
Insulation coordination for electrical equipment EN 60947-1/VDE 0660 part 100 (12.99)
EN 61558-2-1 / DIN VDE 0570 part 2-1 (07.98)
within low-voltage systems - Principles require- Low-voltage switchgear and controlgear -
Safety of power transformers, power supply units
ments and tests general rules
and similar - particular requirements for separa-
ting transformers for general use
IEC 204-1 / EN 60204 part 1 / DIN VDE 0113 part 1 IEC 439-1 / EN 60439-1 /
(11.98) DIN VDE 0660 part 500 (08.00)
EN 61558-2-2 / DIN VDE 0570 part 2-2 (10.98)
Electrical equipment of industrial machines; Low-voltage switchgear and controlgear assem-
Safety of power transformers, power supply units
general requirements blies; requirements for type-tested and partially
and similar - particular requirements for control
type-tested assemblies
transformers
DIN VDE 0118 part 1 (11.01)
Erection of electrical installations in mines -General DIN EN 60127-2
EN 61558-2-4 / DIN VDE 0570 part 2-4 (07.98) DIN VDE 0820 part 2 (09.01)
requirements Safety of power transformers, power supply units Miniature fuses - Cartridge fuse-links
and similar - particular requirements for isolating
DIN VDE 0160 (04.98) transformers for general use EN 50 022 (1977) / DIN EN 50022 (05.78)
Electronic equipment for use in power installa-
Low-voltage switchgear and controlgear for
tions EN 61558-2-6 / DIN VDE 0570 part 2-6 (07.98) industrial use; mounting rails, top hat rails 35 mm
Safety of power transformers, power supply units wide for snap-on mounting of equipment
EN 50014 / DIN VDE 0170/0171 part 1 (02.00) and similar - particular requirements for safety
Electrical apparatus for potentially explosive isolating transformers for general use EN 50 035 (1978) / DIN EN 50035 (04.80)
atmospheres - general requirements Low-voltage switchgear and controlgear for
EN 61558-2-13 / DIN VDE 0570 part 2-13 (08.00) industrial use; mounting rails; mounting rails for
EN 50019 (1978) / DIN VDE 0170/0171 part 6 terminal blocks
Safety of power transformers, power supply units
(06.01)
and similar - particular requirements for auto
Electrical apparatus for potentially explosive EN 50 045 (1980) / DIN EN 50045 (04.82)
transformers for general use
atmospheres - increased safety "e" Low-voltage switchgear and controlgear for
industrial use; mounting rails, top hat rails 15 mm
EN 61558-2-15 / DIN VDE 0570 part 2-15 (11.01)
EN 50020 (1978) / DIN VDE 0170/0171 part 7 wide for mounting of terminal blocks
Particular requirements for isolating transformers
(04.96)
for medical rooms DIN EN 50081-1 (03.93)
Electrical apparatus for potentially explosive
atmospheres - intrinsic safety "i" Electromagnetic compatibility (EMC) - generic
EN 61558-2-17 / DIN VDE 0570 part 2-17 (07.98) emission standard - residential, commercial and
DIN VDE 0220 part 1 (11.71) Safety of power transformers, power supply units light industry (VDE 0839 part 81-1)
Specifications for detachable cable clamps to and similar - particular requirements for trans-
be used in power cable installations up to 1000V formers for switch mode power supplies DIN EN 50081-2 (03.94)
Electromagnetic compatibility (EMC) - generic
EN 61558-2-19 / DIN VDE 0570 part 2-19 (09.01) emission standard - part 2: industrial environment
IEC 112 (1979) / DIN VDE 0303 part 1 (06.84)
Particular requirements for interference reduction (VDE 0839 part 81-2)
Method for determining the comparative and the
proof tracking indices of solid insulating materials transformers
DIN EN 50082-1 (11.97)
under moist conditions
Electromagnetic compatibility (EMC) - generic
EN 61558-2-20 / DIN VDE 0570 part 2-20 (04.01)
immunity standard - residential, commercial and
IEC 529 (1989) / DIN VDE 0470 part 1 (09.00) Particular requirements for miniaturized reactors
light industry (VDE 0839 part 82-1)
Degrees of protection provided by enclosures
(IP Code) EN 50091-1-2 / DIN VDE 0558 part 512 (05.99) DIN EN 61000-6-2 (03.00)
Uninterruptible power systems (UPS) - general and Electromagnetic compatibility (EMC) - generic
DIN VDE 0550 part 3 (12.69) safety requirements for UPS used in restricted immunity standard - industrial range (VDE 0839
Particular requirements for control transformers as access location part 6-2)
well as for mains-supply and insulating transformers
above 1000V

1/4
allg_041014.qxd 14.10.2004 09:58 Seite 5

DIN EN 61000-3-2 (12.01) / VDE 0838 part 2 DIN 41576 DIN 43714 (06.79)
Electromagnetic compatibility (EMC) - limits for Instrument fuses Measuring, control; electric temperature detec-
harmonic current emissions Indicating fuse links 250 V, interchangeable tors; compensating leads for thermocouples

IEC 38 (1983) / DIN IEC 38 (05.87) DIN 41611 part 4 (04.86) DIN 46234 (03.80)
IEC-standard voltages Solderless electrical connections, clip connec- Cable sockets for solderless connections; ring-
tions, terminology, requirements, tests shape without protective sleeve for copper
IEC 326-3 (1980) / IEC 326-3A (1982) conductors
DIN IEC 326 part 3 (03.85) IEC 512-3 (1976) / DIN 41640 part 3 (07.84)
Printed circuits, circuit boards, design and use of Testing procedures and measuring methods for DIN 46237 (07.70)
circuit boards electromechanical components; Crimp-type cable sockets for solderless
Test 5 b: current-carrying capacity connections, insulated, for copper conductors
IEC 352-1 (1983)
DIN IEC 352 part 1 (05.87) IEC 127 (1974) / DIN 41660 (05.79) DIN 46247
Solderless electric connections, wire-wrap con- Instrument fuses Pin bushings without protective sleeve
nections, general requirements, testing methods Fuse links 5 mm x 20 mm, quick, high breaking
and practical guidance capacity IEC 304 (1982) / DIN 47002 (08.87)
Colors for low frequency cables and wires
IEC 760 (1989) / IEC 127 (1974) / DIN 41661 (05.79)
DIN IEC 760 (04.91), draft, Instrument fuses DIN 49515 (12.83)
rectangular cable connections Fuse links 5 mm x 20 mm, quick, low breaking D-fuse links D II, D III, D IV H, 500 V
capacity
DIN 40802 part 2 (02.76) DIN 49522 (04.81)
Metal laminated base materials for printed IEC 127 (1974) / DIN 41661 (05.79) D-fuse links D 01, D 02, D 03, 380 V, 250 V ~
circuits, types Instrument fuses
Fuse links 5 mm x 20 mm, slow, low breaking DIN 49360
IEC 740 / DIN 41302 capacity D-fuses
Laminations for transformers and inductivities for
use in telecommunication and electronic equip- IEC 127 (1974) / DIN 41668 (05.79) ISO/DIS 8820 (1988) / DIN 72581 part 3 (08.87)
ment Instrument fuses Fuses for low voltage installations; blade type
Fuse links 6,3 mm x 32 mm, quick, low breaking fuse links
DIN 41571 capacity
Instrument fuses VBG 4 (04.79)
Fuse links 250 V, interchangeable Electrical installations and appliances

Examples from series production

Single-phase control transformer, Single-phase control transformer, Single-phase control transformer,


EEx e II - approved type RSTE C -approved type RSTN UL with special screening type RSST
®

KEMA-No. Ex-95.D.3337.U UL-No. E 164203 M (USA + Canada) DGBM

Custom made: Custom made: Custom made:


Safety supply, Increased safety, 16 2/3 Hz - 51 Hz, vibration resistance
application in automotive industry application in weaving machines up to 3 G,
application in trains

1/5
allg_041014.qxd 14.10.2004 09:58 Seite 6

Conversion of low-voltage systems comp. to DIN IEC 38


DIN IEC 38 "IEC- standard voltages" has determined to replace previous standard voltages 220V/380V and
240V/415V by standardized voltages 230V/400V.

Public power supply companies have largely completed their conversion to the new standardized voltages.
Accordingly, Riedel has converted all series products to the new standardized voltages and voltage tolerances.

All Riedel transformers and power packs featuring the old standard voltages 220V/380V can also be operated without
impairment on mains with 230V/400V. The output voltage proportionally increases very slightly.

All Riedel standard products feature +-5% tappings allowing voltage adaptation to the new mains.

until 1987

from 1988
until 2003
from 2003
onwards

Limit values for rated direct voltage comp. to DIN EN 61131-2 / part 2 (05.95)
Riedel power packs provide electronic controls with the permissible operational voltage independent from load and
line voltage fluctuations comp. to DIN IEC 38. Thanks to close magnetic coupling and a generous design, Riedel power
packs provide a stable voltage remaining within limit values for direct voltages laid down in DIN EN 61131-2.

Excerpt from the norm:


Rated value (Ue) 24VDC: -15%/+20% tolerance (min-max)
Rated value (Ue) 48VDC: -15%/+20% tolerance (min-max)

Annotation 1: Apart from voltage tolerances a total alternating voltage component with peak value of 5% of rated vol-
tage is permissible. Absolute limits are: 30/19,2V direct voltage for 24V direct voltage and 60/38,4V di-
rect voltage for 48V direct voltage.

1/6
allg_041014.qxd 14.10.2004 09:58 Seite 7

Protection systems
Protection systems are indicated by abbreviations always starting with code letters IP followed by two code numbers
for the protection rate (comp. to EN 60529).
Protection ratings for protection against accidental contact and foreign bodies
First Protection degree
code
no. Designation Definition

0 No protection No special protection of persons against direct contact with active parts.
No protection against penetration of solid foreign bodies.

2 Protection against me- Protection against finger contact with active parts.
dium-sized foreign bodies Protection against penetration of solid foreign bodies (diameter greater 12 mm).

4 Protection against grain Protection against contact with active parts via tools, wires or similar with a thickness greater 1 mm.
shaped foreign bodies Protection against penetration of solid foreign bodies (diameter greater 1 mm).

5 Protection against Full protection against contact with active parts.


dust deposits Protection against harmful dust deposits. Dust penetration is not entirely prevented, but must not
impair function.

6 Protection against Full protection against contact with active parts.


dust penetration Protection against dust penetration.

Protection ratings for water protection


Second Protection degree
code
no. Designation Definition

0 No protection No particular protection

1 Protection against Water drops striking vertical must have no harmful effect.
water drops
falling vertical

3 Protection against Water falling at any angle up to 60° from the vertical must have no harmful effect.
spraying water

4 Protection against Water splashing from any direction must have no harmful effect.
splashing water

5 Protection against Water projected by a nozzle against transformer from any direction must have no harmful effect.
water jets

6 Protection at Water must not penetrate transformer in harmful quantities at temporary overflow.
overflow

7 Protection at Water must not penetrate in harmful quantities when transformer is


immersion immersed in water within laid down pressure and time conditions.

. . . bar

For firedamp and explosion-proof transformers initials SCH respectively EX are used also.

Protection classes
Protection class is a constructional equipment feature about safety against dangerous body flows.
Open frame transformers destined to be installed in switch cabinets or systems do not possess a protection class.
They can only be prepared for it.
Protection class I: System with protective earth terminal and basic insulation
Protection class II: System without protective earth terminal with double or reinforced insulation
Protection class III: System without protective earth terminal whereby protection against dangerous body flows rests
on supply with protection low voltage (SELV) and no higher voltage can be produced than protec-
tion low voltage.

1/7
allg_041014.qxd 14.10.2004 09:58 Seite 8

Safe clamping and protection against accidental contact


Accident prevention regulation (UVV) VBG 4 issued by the professional association for precision and electrical enginee-
ring is directed at operators of electrical installations. Its special safety requirements aim to prevent electrical accidents.
The regulation lays down safety clearances for work, operation and occasional handling close to shock- hazardous
parts, so-called "active parts", of low-voltage installations up to 1000 V ~ resp. 1500V-.
Work on active, i.e. shock-hazardous parts is permissible only after ensuring that same are no longer active. Operating
near active parts is only permissible, if parts are dead or protected against direct contact (§ 6). Safety measures while
working near active parts are
– establishing dead condition for the duration of works
or
– preventing direct contact by covering or setting up barrier during works
or
– ensuring that permissible proximity is observed (§ 7)
For operation of elements such as pushbuttons, snap switches, knobs close to shock-hazardous parts, the term
"occasional handling" was introduced. According to DIN VDE 0105-1 it is an "operation with partial protection against
direct contact".
Detailed regulations for "occasional handling" may be found in DIN VDE 0106-100. Among others it regulates the
degree of cover required for active parts in the proximity of operating controls and bases on the definition of a "protec-
tion area for occasional handling"; it is the area into which one must reach occasionally during handling.
It is essential, that a level envelope of 30 mm radius surrounding the active parts is finger-safe, i.e. according to IEC
529/DIN VDE 0470-1 (test finger) shock-hazardous parts of electric apparatus must not be touchable by a straight
VDE-test finger.
For the "more distant" area up to 100 mm surrounding the control element, back of hand safety is obligatory. Back of
hand safety is given, when a force of 50 N is exerted on a sphere of 50 mm diameter and no contact is made with
shock-hazardous part of appliance.
Outside this area no particular measure for contact safety is required.

Finger-safe

Back of the hand safe

Annotation: Equipment and appliances operated with protection low voltage up to 25 V ~ or 60 V - are considered
"protected against direct contact".
According to VBG 4, § 5 / section 4, system inspection for due order prior to first startup may be scraped when the
company receives confirmation from the manufacturer or installer stating that electric system and appliances concur
with regulations VBG 4. The required confirmation refers to installed, ready to service systems and appliances and may
only be submitted by the installer or assembly company. The manufacturer of electric appliances may just confirm that
his products comply to relevant electrotechnical DIN VDE regulations stated in VBG 4. It is the installer's duty to select
fitting appliances according to these aspects.

1/8
allg_041014.qxd 14.10.2004 09:58 Seite 9

Technical information and directions

Terms and requirements


Referring to the inductivities stated in the catalogue following terms and requirements represent just a small excerpt
from the great variety that could be named. We have limited ourselves to the relevant terms and requirements impor-
tant for your selection. At wish you may certainly obtain further information from us.

Transformers in general
A transformer is a static unit featuring two or more windings which by electromagnetic induction transforms a system
of alternating voltage and alternating current, usually with different values at the same frequency, as a means to trans-
mit electric energy (ref: VDE 0570, IEV 421-01-01).

Insulation
Transformers' constructive differences are principally determined by their designated application. Corresponding
requirements are stated in installation and appliance norms (for example VDE 0100, VDE 0113, VDE 0700, VDE 0800)
and transformer norms (for example VDE 0550, VDE 0551, VDE 0570).
An important criteria for selection is the insulation layout between input and output circuits:

Inductivity For protective measure Requirement Insulation system Pri-Sec

Isolation transformer Protective isolation “high” Double or reinforced


safe isolation insulation

Safety transformer Protection low voltage “high” Double or reinforced


safe isolation insulation

Power transformer (separate winding) “low” Basic insulation


non-safe isolation

Control transformer Protective earthing “low” Basic insulation


non-safe isolation

Auto transformer (no separate winding) not -


indirect-coupled

Transformers with separate windings


Such transformers do not have a conductive connection between individual windings. They are indirect-coupled.

Primary voltage

Secondary voltage

Tappings
Transformers may be designed with primary as well as secondary tappings.
Primary tappings serve to adjust and apply a transformer in diverse supply voltages. The increased winding space
requirement frequently necessitates turning to the next larger transformer type. There is no need for enlargements at
mains adaption of app. 5 %.
2 primary voltages

Secondary voltage

The need for further winding space also does not occur when a second primary voltage halved results in the first (for
example 115 V - 230 V).

1/9
allg_041014.qxd 14.10.2004 09:58 Seite 10

If two equal winding parts are connected in series or parallel the transformer can be used for both secondary voltages
while retaining full output. Observe stated polarity!

Transformer switched to 115V Transformer switched to 230V

In case of several secondary voltages, rated secondary current intensity is calculated based upon the highest secon-
dary voltage. Therefore tappings can only be loaded with current intensity calculated from power and highest secon-
dary voltage.
If full power is required for each individual secondary voltage, power or current intensity must be stated individually. It
calls for further space requirement and possibly the next larger transformer type.

Transformers in economy winding


Economy windings show conductive connection between primary and secondary winding. The output power is trans-
ferred partly inductive and partly by current capacity. It may result in considerable size reduction as compared to trans-
formers with separate windings. The smaller the difference between input and output voltage, the smaller the trans-
former.
Example: Transformer rated output 1000 VA
undervoltage
upper voltage
230 V
400 V
type power N = nominal power x
( 1-
undervoltage
upper voltage )
Primary voltage

type power N = 1000


( 1-
230
400 ) = 1000 x 0,425 = 425 VA

Secondary voltage

Therefore instead of a 1000 VA-sized transformer just one 425 VA in size is needed.

Operation modes
All Riedel standard transformers are designed for continuous operation S1. S1-operation is at hand, when a transformer
operates any given time under permissible thermal rated current and the other remaining rated values. The declaration
corresponds to 100% ED (on-period). Additionally, there are transformers that may be loaded higher for some time
when a lower load has preceded.

Short-time load (standard S3 at declaration of ED in %) - on-period calculates as follows:


Load period in min.
ED = x 100 (%)
Duty cycle in min.

Duty cycle (off-time period + load duration) must not exceed 10 min., duty cycle > 10 min. is continuous operation.

Type power at short-time load calculates as follows:

NT = N x
冪 ED (%)
100
NT = type power
N = nominal power

Further operation modes:


S2 (singular load with long off-time period), S4, S5 (intermittent operation), S6 (continuous duty with intermittent
loading), S7 (uninterrupted operation with varying rated current during start and/or end of duty cycle), S8 (just as S7, but
with any number of variation from rated current in fixed duration and level during one cycle (duty cycle)). We manufac-
ture for these operation modes on request.

1/10
allg_041014.qxd 14.10.2004 09:58 Seite 11

Power
All stated power data refers to collected secondary power in VA resp. kVA at continuous operation, excitation with
rated voltage, rated frequency, cos. phi = 1, an ambient temperature of max. 40°C and a set-up altitude up to 1000 m
above sea level (NN).
Power is calculated from rated secondary voltage (volt) and rated secondary current (ampere) into VA or kVA.

Power reduction dependent on set-up altitude


of rated power
Load in %

Short-time rating of transformer


The layout of control transformers in control circuits with chief power demands by contactor coils and relay coils ensues
according to the possible short-time rating (initial power of coil) at a cos f = 0,5 and a voltage drop of maximal 5%.

Frequency
Transformers stated in catalogue are suitable for mains with rated frequency 50 - 60 Hz. The rating plate states 50/60 Hz.
Stated losses, voltage drops and efficiency refer to rated frequency 50 Hz. Frequencies other than 50 Hz cause a
change in type power according to following chart:
f (Hz) 16 2/3 40 42 50 60 75 100 200 300
N (%) 35 80 84 100 110 115 130 135 140

Rated power in mains with 60 Hz must not be exceeded, if it is a normal transformer with rating plate statement of
50/60 Hz.

Heating
Free access of cooling air must be ensured. At ambient temperatures above 40°C rated power must be reduced
according to following chart:
°C 45 50 55 60
N (%) 95 85 80 75

Temperature rise
Principally transformers can be operated at higher power for a short time, but only if highest permitted medium tem-
perature rise is adhered to and prior continuous load was beneath 100%..

Overload chart:
Prior continuous Permissible duration of overload in % of rated power
load in %
of rated power 150 % 140 % 130 % 120 % 110 %

50 30 min. 45 min. 65 min. 105 min. 180 min.

60 25 min. 40 min. 60 min. 95 min. 170 min.

70 20 min. 30 min. 45 min. 80 min. 155 min.

80 15 min. 25 min. 40 min. 75 min. 140 min.

90 8 min. 15 min. 30 min. 60 min. 120 min.

1/11
allg_041014.qxd 14.10.2004 09:58 Seite 12

Temperatures
During rated conditions transformers produce losses which transpose into heat. According to regulations this "self -
heating" resp. "overtemperature" is bound to limit values by insulation class of insulating material and under considera-
tion of ambient temperature. These values concern the winding and components directly in contact to it. Following
chart refers to the medium temperature rise of overtemperatures at an ambient temperature of 40°C.
According to regulations the "hot spot" of class A can exceed following chart value 5K and class H 15K depending on
insulation class. We manufacture in all stated insulation classes on request.

Insulation class Final temperature

A 105°C

E 1 1 5°C

B 120°C

F 140°C

H 175°C

We recommend not to apply class H because of poor efficiency.

Short circuit strength


Transformers are subdivided according to their short circuit strength (ref: VDE 0570, EN 61558, IEC 61558):
A short circuit proof transformer is a transformer whose temperature does not exceed set limit values at overload or short
circuit and who will fulfill all requirements of above stated regulations as before once overload or short circuit has been
removed.
a. An absolutely short circuit proof transformer is a short circuit proof transformer without protective device whose tem-
perature does not exceed set limit values at overload or short circuit and who can be operated again once overload
or short circuit is removed.
Remark: Because of their physics such transformers allow constructions with little rated active power up to 4 VA
only. The no-load voltage factor can reach a value up to 2. The curve shape of output voltage can deviate from sinus-
oidal wave shape. Absolutely short circuit proof transformers must not necessarily be sustained short circuit proof.
b. A relatively short circuit proof transformer is a short circuit proof transformer with a built-in protective device which
opens the circuit or limits the current in input or output circuit when transformer is overloaded or short circuited.
Remark: Examples for protective devices are fuses, overload circuit breakers, temperature fuses, temperature
limiters with or without automatic reset, PTC resistors and automatically acting mechanical safety switches.
A non-circuit proof transformer is a transformer destined to be protected against excess temperature via a protective device
which is not built-into the transformer.
Remark: Unless otherwise agreed, transformer protection is taken care of by the customer.

Fusing
Observe the following for transformer fusing:
1. Selection of fuse media is determined by their ratings such as permissible voltage and current, their release charac-
teristics and breaking capacity.
In this connection consider that depending on fuse selection eventually back-up protection (advance fuse) may be
necessary to cover the entire current / time spectrum.
2. To pinpoint fuse value normally one must differentiate between primary and secondary side of transformer.
The "safe release" of a fuse in connection with transformers is more simple via the secondary side, i.e. fuse selection is
easier because rated current is close to rated current of fuse. The fuse protects transformers reliably against short
circuit and excess output overload. The overcurrent protection of a transformer, for example caused by interturn short
circuit, can only be realized via primary-side fuses. But because of the inrush any fuse value must usually be calculated
several times higher than rated current of transformer would demand. Therefore such fuses function more as short
circuit protection than overload protection.
Concerning this there are remedies though such as inrush current limiters to select fuse value close to rated current of
transformer.

1/12
allg_041014.qxd 14.10.2004 09:58 Seite 13

There is a causal link between fuse value, fuse type, (large) line lengths, ambient temperature and permissible trans-
former temperature (acc. to regulation) in order to achieve optimal protection and operational conditions. Recom-
mended fuse values stated on rating plates and data sheets of Riedel- transformers solely refer to transformer protec-
tion. The fuses must be placed directly after resp. in front of the transformer. When rated conditions deviate (for example
ambient temperature) fuse values must be corrected. In priority our fuse recommendations base on instrument fuses
(blow-out fuses), automatic circuit breakers and motor circuit breakers. Optimal protection is ensured with transformer
circuit breakers available on the market because they are adjusted to inrush characteristic of transformers.
Remark: Observe current translation during overload in case of primary fusing for variable ratio ring transformers and
transformers with several output voltages or output windings.

Three-phase transformers

Load capacity of neutral point (star point):


Regarding neutral point load capacity of three-phase transformers, observe below following to avoid additional losses
and neutral point shifting:
Star-star connection:
The neutral point may only be loaded with full rated current (line-to-line current) when neutral conductor of
supply line is connected rigidly to primary neutral point of transformer. Otherwise, neutral point may only be
loaded with app. 10% line-to-line current.
The same rule applies for three-phase auto transformers in star-economy design.
Taking no special measures, following connection modes amount to 100% load of neutral point:
Delta-star connection with secondary extended neutral point Dy5
Star-zigzag connection with secondary extended neutral point Yz5
If three-phase sets are formed via 3 single-phase transformers, then load of neutral point must definitely be avoided.

Vector groups Designation


Vector diagram Circuit configuration
Secondary
Code no. Vector group star point
The vector group marks the circuitry of windings and
their phase position to each other. It consists of a
capital and small letter plus a code number. none

The capital letter refers to the input winding, the small 10% load
capacity
to the output winding. The upper voltage is marked by
1 in front, the undervoltage by a 2 in front, regardless
of input- or output voltage. A 1 in back, on the con- full load
capacity
trary, marks the beginning of a winding, a 2 in back the
end. Tabs are marked 3 and 4 in back. The numbers full load
correlate to letters U V W and distinguish the 3 capacity

phases. The neutral point (star point) is always mar-


ked N. none

The most common vector groups are summarized


full load
alongside, input left-hand, output right-hand. capacity

Unless otherwise requested, three-phase trans-


formers are preferentially delivered in star-star con- none
nection.
10% load
capacity

full load
capacity

full load
capacity

none

full load
capacity

10% load
capacity

1/13
allg_041014.qxd 14.10.2004 09:58 Seite 14

Power supplies with D.C.-output


Depending on the type of supply voltage we differentiate between power supplies (A.C./D.C. converters) and D.C./D.C.-conver-
ters. Power supplies are operated with alternating current resp. three-phase current. D.C./D.C.-converters operate with D.C.-cur-
rent.
Battery chargers are A.C/D.C.- or D.C./D.C.-converters with a special output characteristic adjusted to the battery.
D.C.-UPS (non-interruptible power supplies with battery in D.C.-output) can be done as online- or offline systems.
In the case of an offline-UPS the power supply of the user ensues at normal operation through the supply line via a power supply
unit and the battery is charged via a battery charger. The user is switched to the battery at power supply failure.
The battery in an online-system is constantly connected to the user, also during line operation. The adjusted output voltage is iden-
tical with the battery voltage, for example 26,6 V for a 24V-system.
Riedel-RDCUSV-series avoids the necessary high stabilized charging voltage on the user during normal operation. The analog
controlled switch to battery operation ensues without gaps and controls the output voltage to the adjusted threshold value. The
patented Riedel-charging system allows to charge the accumulators without a boost chopper and does not create EMC-inter-
ference.
Power supply units for low voltages with D.C.-output are defined in EN 61204.

Output parameters
Output value
The output value at constant voltage operation is the output voltage, at constant current operation it is the output current.
Rated output voltage
Rated output voltage is the voltage available at connection point. Connection point at operation with sense-lines is the user itself,
in any other case it is the unit's socket.
Rated output current
Rated output current is the current available at the unit's output, allowing constant operation of unit.
Rated output power P
Product of rated voltage times rated current. At multiple output: sum total of all products.
Output power reduction at higher ambient temperatures
Is stated in % / K.
Parallel operation and series operation of units
For higher output power identical units can be switched in parallel or series. At series operation stated maximal constant voltage
between output and housing should be observed.
Redundancy
a. When outputs are switched in parallel by individual units only reduced redundancy is achieved. When a defect occurs in the
primary circuit of a unit, the other unit takes over complete current supply automatically and without interruption.
b. 100% redundancy requires decoupling diodes. For series RPL types 125 W and 250W we offer our customers internal decoup-
ling diodes (at a surcharge), for the rest of the units an external additional module featuring decoupling diodes and interferen-
ce reports.
Adjustment range of output size
The term adjustment range is relevant for controllable units only.
a. the adjustment range is stated at rated supply voltage and at half rated load. The user should remember, that when the out-
put voltage is raised the output current by rule reduces according to rated output power.
b. b. Solution of adjustment is stated as relative value in %.
Changing the output value
a. via internal potentiometer
b. via external potentiometer
c. via analog input such as 0 - 10 VDC or 4 - 20 mA.
Periodical and non-periodical tolerances = ripple and noise voltage
a. low frequency noise = power line hum. Plays no role in D.C./D.C.-converters. Only relevant at connection of unit to alternating
current mains resp. three-phase mains.
b. Switching noise. Only switching frequency and its harmonics
c. Complete noise inclusive overshoot peaks (application of measuring devices featuring adequate bandwidth necessary).

1/14
allg_041014.qxd 14.10.2004 09:58 Seite 15

Line correction
Relative change of output size, in % for set range of supply voltage and supply frequency at constant load, according to norm at
50 % of rated load. Line correction of 0,1% at output voltage of 24 VDC signifies that the absolute change of the output voltage
at change of supply voltage of minimal to maximal value is (0,1 % x 24V) /100 % = 24 mV.
Load correction
Relative change of output size, in % for set load range at constant supply voltage. The most unfavorable value of supply voltage
is stated.
Temperature coefficient
Relative change of output size, in % / K for set temperature range.
Tolerance of output size
Is stated in % for units with set rated supply voltage and at half rated load.
Dynamic behavior at load changes for a set range
a. deviation of output size is the maximal change of output size, set as percentage, which was caused by a load change.
b. recovering time (correction time) is the time span between load leap and the time when the output size returns to the set tole-
rance width.
The rise- and fall flanks of the load change should be less than a tenth of the set recovering time.
Output overcurrent protection
a. constant current characteristics
b. reverse characteristics
c. trigger characteristics
d. short-circuit proof characteristics (not protected against continued overload).
Our linear controllers realize reverse characteristics. Our switched units feature short-circuit proof and overload proof characte-
ristics.
Output overvoltage protection
a. protection circuit with short circuit of output
b. electronic lock
c. lock with 'reset'-system
Most of our units feature a breakdown-protection circuit.

Input parameters
Rated voltage
Standard value of supply voltage, for which the unit is designed.
Voltage range
From the minimal value to the maximal value of voltage
Supply current
a. effective value of supply current
b. peak value of supply current (only alternating voltage- resp. three-phase sources).
c. Highest inrush current. The charging current of the suppression capacitors in the first milli second is to be ignored.
d. The harmonic factor of the supply ripple.
Power factor (only alternating voltage- resp. three-phase sources).
Power factor ␭ is the rate of true power PE and vector power SE at input.
␭ = PE / SE
If voltage and current are sinusoidal, then power factor is as the cos ␸ between voltage and current. Because the power supplies
feature a pulse shaped current pickup following is valid:
␭ = ␹ * cos ␸
␹ - distortion factor of supply current
Distortion factor ␹ is the ratio of effective value of the fundamental wave and effective value of the total current.
Efficiency
Efficiency is the ratio of true powers at output and input:
␩ = PA /PE,
PA - true power at output
PE - true power at input
Power-line failure bridging time (hold time)
This time is named retention time in the norm (switch-off-decay time) and should be stated in +10% at rated output voltage, rated
output power and minimum supply voltage.

1/15
allg_041014.qxd 14.10.2004 09:58 Seite 16

SALES- AND DELIVERY CONDITIONS

I. GENERAL 5. At the Supplier's request the Purchaser shall declare within a


1. The scope of deliveries and/or services (hereinafter referred reasonable period of time whether the Purchaser cancels the
to as "Supplies") shall be determined by the written declara- contract due to the delayed Supplies or insists on the Supplies
tions of both Parties. General terms and conditions of the Pur- to be carried out.
chaser shall apply only if and when expressly accepted by the 6. If dispatch or shipment is delayed at the Purchaser's request
supplier or the provider of services (hereinafter referred to as by more than one month after notice of the readiness for di-
"Supplier") in writing. spatch was given, the Purchaser may be charged, for every
2. The Supplier herewith reserves any industrial property rights month commenced, storage costs of 0.5 % of the price of the
and/or copyrights pertaining to its cost estimates, drawings items of the Supplies, but in no case more than a total of 5 %.
and other documents (hereinafter referred to as "Docu- The parties to the contract may prove that higher or, as the ca-
ments"). The Documents shall not be made accessible to third se may be, lower storage costs have been incurred.
parties without the Supplier's prior consent and shall, upon re- V. TRANSFER OF RISK
quest, be returned without undue delay to the Supplier if the 1. Even where delivery has been agreed freight free, the risk shall
contract is not awarded to the Supplier. Sentences 1 and 2 pass to the Purchaser as follows:
shall apply mutatis mutandis to documents of the Purchaser; a) if the Supplies do not include assembly or erection, at the time
these may, however, be made accessible to third parties to when the Supplies are shipped or picked up by the carrier.
whom the Supplier may rightfully transfer Supplies. Upon request of the Purchaser, the Supplier shall insure the
3. Partial Supplies shall be allowed, unless they are unreasonable Supplies against the usual risks of transport at the expense of
to accept for the Purchaser. the Purchaser.
II. PRICES AND TERMS OF PAYMENT b) if the Supplies include assembly or erection, at the day of ta-
1. Prices shall be ex works and exclude packaging; value added king over in the own works or, if so agreed, after a fault-free tri-
tax shall be added at the then applicable rate. al run.
2. If the Supplier is also responsible for assembly or erection and 2. The risk shall pass to the Purchaser if dispatch, shipping, the
unless otherwise agreed, the Purchaser shall pay the agreed start or performance of assembly or erection, the taking over
remuneration and any incidental costs required, e. g. travel in the own works or the trial run is delayed for reasons for
costs, costs for the transport of tools and equipment, and per- which the Purchaser is responsible or if the Purchaser has
sonal luggage as well as allowances. otherwise failed to accept the Supplies.
3. Payments shall be made free Supplier's paying office. VI. ASSEMBLY AND ERECTION
4. The Purchaser may set off only those claims that are undispu- Unless otherwise agreed in writing, assembly/erection shall be
ted or against which no legal recourse is possible. subject to the following provisions:
III. RETENTION OF TITLE 1. The Purchaser shall provide at its own expense and in good ti-
1. Items pertaining to the Supplies ("Retained Goods") shall re- me:
main the property of the Supplier until each and every claim a) all earth and construction work and other ancillary work outsi-
the Supplier has against the Purchaser on account of the busi- de the scope of the Supplier, including the necessary skilled
ness connection has been fulfilled. If the combined value of the and unskilled labour, construction materials and tools,
security interests of the Supplier exceeds the value of all secu- b) the equipment and materials necessary for assembly and
red claims by more than 20 %, the Supplier shall release a cor- commissioning such as scaffolds, lifting equipment and other
responding part of the security interest if so requested by the devices as well as fuels and lubricants,
Purchaser. c) energy and water at the point of use including connections,
2. For the duration of the retention of title, the Purchaser may not heating and lighting,
pledge the Retained Goods or use them as security, and resa- d) suitable dry and lockable rooms of sufficient size adjacent to
le shall be possible only for resellers in the ordinary course of the site for the storage of machine parts, apparatus, materials,
their business and only on condition that the reseller receives tools, etc. and adequate working and recreation rooms for the
payment from its customer or makes the transfer of property erection personnel, including sanitary facilities as are appropri-
to the customer dependent upon the customer fulfilling its ate in the specific circumstances. Furthermore, the Purchaser
obligation to effect payment. shall take all measures it would take for the protection of its
3. The Purchaser shall inform the Supplier forthwith of any seizu- own possessions to protect the possessions of the Supplier
re or other act of intervention by third parties. and of the erection personnel at the site,
4. Where the Purchaser fails to fulfil its duties, including failure to e) protective clothing and protective devices needed due to par-
make payments due, the Supplier shall be entitled to cancel ticular conditions prevailing on the specific site.
the contract and take back the Retained Goods in the case of 2. Before the erection work starts, the Purchaser shall make
continued failure following expiry of a reasonable time set by available of its own accord any information required concer-
the Supplier; the statutory provisions that a time limit is not ning the location of concealed electric power, gas and water li-
needed remain unaffected. The Purchaser shall be obliged to nes or of similar installations as well as the necessary structural
surrender the Retained Goods. data.
3. Prior to assembly or erection, the materials and equipment ne-
IV. TIME FOR SUPPLIES; DELAY cessary for the work to start must be available on the site of
1. Times set for Supplies can only be observed if all Documents assembly/erection and any preparatory work must have ad-
to be supplied by the Purchaser, necessary permits and vanced to such a degree that assembly/erection can be star-
releases, especially concerning plans, are received in time and ted as agreed and carried out without interruption. Access ro-
if agreed terms of payment and other obligations of the Pur- ads and the assembly/erection site itself must be level and cle-
chaser are fulfilled. Unless these conditions are fulfilled in time, ar.
times set shall be extended appropriately; this shall not apply 4. If assembly, erection or commissioning is delayed due to cir-
where the Supplier is responsible for the delay. cumstances for which the Supplier is not responsible, the Pur-
2. If non-observance of the times set is due to force majeure chaser shall bear the reasonable costs incurred for idle times
such as mobilization, war, rebellion or similar events, e. g. strike and any additional travelling of the Supplier or the erection per-
or lockout, such time shall be extended accordingly. sonnel.
3. If the Supplier is responsible for the delay (hereinafter referred 5. The Purchaser shall attest to the hours worked by the erection
to as "Delay") and the Purchaser demonstrably suffered a loss personnel towards the Supplier at weekly intervals and the
therefrom, the Purchaser may claim a compensation as liqui- Purchaser shall immediately confirm in writing if assembly, er-
dated damages of 0.5 % for every completed week of Delay, ection or commissioning has been completed.
but in no case more than a total of 5 % of the price of that part 6. If, after completion, the Supplier demands acceptance of the
of the Supplies which because of the Delay could not be put to Supplies, the Purchaser shall comply therewith within a period
the intended use. of two weeks. In default thereof, acceptance is deemed to ha-
4. Purchaser's claims for damages due to delayed Supplies as ve taken place. Acceptance is also deemed to have been ef-
well as claims for damages in lieu of performance exceeding fected if the Supplies are put to use, after completion of an
the limits specified in No. 3 above shall be excluded in all cases agreed test phase, if any.
of delayed Supplies even upon expiry of a time set to the Sup-
plier to effect the Supplies. This shall not apply in cases of man- VII. RECEIVING OF SUPPLIES
datory liability based on intent, gross negligence, or due to inju- The Purchaser shall not refuse to receive Supplies due to mi-
ry of life, body or health. Cancellation of the contract by the nor defects.
Purchaser based on statute shall be limited to cases where VIII. DEFECTS AS TO QUALITY
the Supplier is responsible for the delay. The above provisions The Supplier shall be liable for defects as to quality ("Sachmän-
do not imply a change in the burden of proof to the detriment gel", hereinafter referred to as "Defects",) as follows:
of the Purchaser.

1/16
allg_041014.qxd 14.10.2004 09:58 Seite 17

SALES- AND DELIVERY CONDITIONS

1. All parts or services where a Defect becomes apparent within existence of an infringement and (iii) leaves any protective me-
the limitation period shall, at the discretion of the Supplier, be asures and settlement negotiations to the discretion of the
repaired, replaced or provided again free of charge irrespecti- Supplier. If the Purchaser stops using the Supplies in order to
ve of the hours of operation elapsed, provided that the reason reduce the damage or for other good reason, it shall be obli-
for the Defect had already existed at the time when the risk ged to point out to the third party that no acknowledgement of
passed. the alleged infringement may be inferred from the fact that the
2. Claims based on Defects are subject to a limitation period of use has been discontinued.
24 months. This provision shall not apply where longer periods 2. Claims of the Purchaser shall be excluded if it is itself responsi-
are prescribed by law according to Sec. 438 para. 1 No. 2 (buil- ble for the infringement of an IPR.
dings and things used for a building), Sec. 479 para. 1 (right of 3. Claims of the Purchaser shall also be excluded if the infringe-
recourse), and Sec. 634a para. 1 No. 2 (defects of a building) ment of the IPR is caused by specifications made by the Pur-
German Civil Code ("BGB"), as well as in cases of injury of life, chaser, to a type of use not fore-seeable by the Supplier or to
body or health, or where the Supplier intentionally or grossly the Supplies being modified by the Purchaser or being used
negligently fails to fulfil its obligation or fraudulently conceals a together with products not provided by the Supplier.
Defect. The legal provisions regarding suspension of expira- 4. In addition, with respect to claims by the Purchaser pursuant
tion ("Ablaufhemmung"), suspension ("Hemmung") and re- to No. 1 a) above, Art. VIII Nos. 4, 5, and 9 shall apply mutatis
commencement of limitation periods remain unaffected. mutandis in the event of an infringement of an IPR.
3. The Purchaser shall notify Defects to the Supplier in writing and 5. Where other defects in title occur, Art. VIII shall apply mutatis
without undue delay. mutandis.
4. In the case of notification of a Defect, the Purchaser may with- 6. Any other claims of the Purchaser against the Supplier or its
hold payments to a reasonable extent taking into account the agents or any such claims exceeding the claims provided for in
Defect occurred. The Purchaser, however, may withhold pay- this Art. IX, based on a defect in title, shall be excluded.
ments only if the subject-matter of the notification of the De- X. IMPOSSIBILITY OF PERFORMANCE; ADAPTATION OF CON-
fect occurred is justified beyond doubt. Unjustified notifications TRACT
of Defect shall entitle the Supplier to have its expenses reim-
bursed by the Purchaser. 1. To the extent that Supplies are impossible to be carried out,
5. The Supplier shall first be given the opportunity to supplement the Purchaser shall be entitled to claim damages, unless the
its performance ("Nacherfüllung") within a reasonable period Supplier is not responsible for the impossibility. The Purchaser-
of time. 's claim for damages shall, however, be limited to an amount of
6. If supplementary performance is unsuccessful, the Purchaser 10 % of the value of the part of the Supplies which, owing to the
shall be entitled to cancel the contract or reduce the remune- impossibility, cannot be put to the intended use. This limitation
ration, irrespective of any claims for damages it may have ac- shall not apply in the case of mandatory liability based on in-
cording to Art. XI. tent, gross negligence or injury of life, body or health; this does
7. There shall be no claims based on Defect in cases of insignifi- not imply a change in the burden of proof to the detriment of
cant deviations from the agreed quality, of only minor impair- the Purchaser. The right of the Purchaser to cancel the con-
ment of usefulness, of natural wear and tear or damage arising tract shall remain unaffected.
after the transfer of risk from faulty or negligent handling, ex- 2. Where unforeseeable events within the meaning of Art. IV No.
cessive strain, unsuitable equipment, defective workman- 2 substantially change the economic importance or the con-
ship, inappropriate foundation soil or from particular external tents of the Supplies or considerably affect the Supplier's busi-
influences not assumed under the contract, or from non-re- ness, the contract shall be adapted taking into account the
producible software errors. Claims based on defects attributa- principles of reasonableness and good faith. Where doing so is
ble to improper modifications or repair work carried out by the economically unreasonable, the Supplier shall have the right to
Purchaser or third parties and the consequences thereof shall cancel the contract. If the Supplier intends to exercise its right
be likewise excluded. to cancel the contract, it shall notify the Purchaser thereof wi-
8. The Purchaser shall have no claim with respect to expenses thout undue delay after having realised the repercussions of
incurred in the course of supplementary performance, inclu- the event; this shall also apply even where an extension of the
ding costs of travel and transport, labour, and material, to the delivery period had previously been agreed with the Purcha-
extent that expenses are increased because the subject-mat- ser.
ter of the Supplies was subsequently brought to another loca- XI. OTHER CLAIMS FOR DAMAGES
tion than the Purchaser's branch office, unless doing so com- 1. Any claims for damages and reimbursement of expenses the
plies with the intended use of the Supplies. Purchaser may have (hereinafter referred to as "Claims for Da-
9. The Purchaser's right of recourse against the Supplier pursu- mages"), based on whatever legal reason, including infringe-
ant to Sec. 478 BGB is limited to cases where the Purchaser ment of duties arising in connection with the contract or tort,
has not concluded an agreement with its customers excee- shall be excluded.
ding the scope of the statutory provisions governing claims 2. The above shall not apply in the case of mandatory liability, e. g.
based on Defects. Moreover, No. 8 above shall apply mutatis under the German Product Liability Act ("Produkthaftungsge-
mutandis to the scope of the right of recourse the Purchaser setz"), in the case of intent, gross negligence, injury of life, bo-
has against the Supplier pursuant to Sec. 478 para. 2 BGB. dy or health, or breach of a condition which goes to the root of
10. Furthermore, the provisions of Art. XI (Other Claims for Dama- the contract ("wesentliche Vertragspflichten"). However,
ges) shall apply in respect of claims of damages. Any other Claims for Damages arising from a breach of a condition which
claims of the Purchaser against the Supplier or its agents or goes to the root of the contract shall be limited to the foresee-
any such claims exceeding the claims provided for in this Art. able damage which is intrinsic to the contract, unless caused
VIII, based on a Defect, shall be excluded. by intent or gross negligence or based on liability for injury of li-
IX. INDUSTRIAL PROPERTY RIGHTS AND COPYRIGHT; DEFECTS IN fe, body or health. The above provision does not imply a chan-
TITLE ge in the burden of proof to the detriment of the Purchaser.
1. Unless otherwise agreed, the Supplier shall provide the Sup- 3. To the extent that the Purchaser has a valid Claim for Dama-
plies free from third parties' industrial property rights and copy- ges according to this Art. XI, it shall be time-barred upon expi-
rights (hereinafter referred to as "IPR") with respect to the ration of the limitation period applicable to Defects pursuant to
country of the place of destination. If a third party asserts a ju- Art. VIII No. 2. In the case of claims for damages under the Ger-
stified claim against the Purchaser based on an infringement man Product Liability Act, the statutory provisions governing li-
of an IPR with respect to the Supplies made by the Supplier mitation periods shall apply.
and then used in conformity with the contract, the Supplier XII. VENUE AND APPLICABLE LAW
shall be liable to the Purchaser within the time period stipulated 1. If the Purchaser is a businessperson, sole venue for all dispu-
in Art. VIII No. 2 as follows: tes arising directly or indirectly out of the contract shall be the
a) The Supplier shall choose whether to acquire, at its own ex- Supplier's place of business. However, the Supplier may also
pense, the right to use the IPR with respect to the Supplies bring an action at the Purchaser's place of business.
concerned or whether to modify the Supplies such that they 2. Legal relations existing in connection with this contract shall be
no longer infringe the IPR or replace them. If this would be un- governed by German substantive law, to the exclusion of the
reasonable to demand from the Supplier, the Purchaser may United Nations Convention on Contracts for the International
cancel the contract or reduce the remuneration pursuant to Sale of Goods (CISG).
the applicable statutory provisions. XIII.SEVERABILITY CLAUSE
b) The Supplier's liability to pay damages shall be governed by
Art. XI. The legal invalidity of one or more provisions of this contract
c) The above obligations of the Supplier shall only apply if the Pur- shall in no way affect the validity of the remaining provisions.
chaser (i) immediately notifies the Supplier of any such claim This shall not apply if it would be unreasonable for one of the
asserted by the third party in writing, (ii) does not concede the parties to continue the contract.

1/17
allg_041014.qxd 14.10.2004 09:58 Seite 18

1/18
A
Copyright: BASF/Riedel Product group

Complex plants in security risk industries require power supplies


to meet strict safety demands. Designing electric and electronic
systems calls for special know-how and uncompromising quality
assurance. We have the know-how in quality, a goog reason to
apply Riedel products.
A_TEIL_041014.qxd 14.10.2004 11:34 Seite 2

Series RSTN
. . . makes for tension in purchase and engineering

In general
RSTN-transformers can be applied worldwide, meet national and international regulations and are ready for those up-
coming. Following designs are available:
Control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2
Isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4, (for sec. 230V only)
Safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6, (for sec. 24V only)

Particular advantages of series RSTN:


- best cost-price (large scale manufacture, extremely favorable price-performance relation)
- high reliability and long service life
- compact construction and low weight
- low total losses, thus high efficiency
(for example reduction of core losses by two-way layering)
- higher than average output at short-time duty
- high performance in comparison to size
- control transformers feature higher value insulation system than regulation dictates
- high voltage stability because of small voltage drop between no-load and load
- voltage adaptation via +-5% taps
- from 130 VA upwards protected against short cut via insulating bushing
- temperature reserves, even at ta 60°C/B full current load possible
- mounting brackets comp. to DIN 41 307
- stock items (except for 500V-type)

Fusing recommendation:
Below stated fusing recommendations refer to transformer's secondary side and safety fuse cartridges comp. to IEC
127 / EN 60127 (A time-lag), or comp. to IEC 60269 (AgL). Concerning this and also for primary fusing please observe
paragraph 'Fusing', catalogue section 'In General'.

Rated current input Current secondary and fusing recommendation

I 1 max. in I 1 max. in I 1 max. in I2 in Fusing I2 in Fusing


Model Model
A A A A A A A
pri. voltage ± 5% 230V 400V 500V sec. voltage 230V 24V
RSTN 50 0,27 0, 16 0, 13 RSTN 50 0,2 1 0,1 6 At 2,08 1 ,60 At
RSTN 75 0,40 0,23 0, 19 RSTN 75 0,32 0,25 At 3,125 2,50 At
RSTN 100 0,52 0,30 0,24 RSTN 100 0,43 0,315 At 4,1 6 3,1 5 At
RSTN 130 0,65 0,38 0,30 RSTN 130 0,56 0,40 At 5,4 1 4,00 At
RSTN 200 1,00 0,57 0,46 RSTN 200 0,86 0,63 At 8,33 6,30 At
RSTN 250 1,23 0,7 1 0,57 RSTN 250 1,08 0,80 At 1 0,4 1 8,00 At
RSTN 320 1,57 0,90 0,73 RSTN 320 1,39 1,00 At 1 3,33 10,0 AgL
RSTN 400 1,94 1, 12 0,90 RSTN 400 1,73 1,25 At 1 6,66 16,0 AgL
RSTN 500 2,42 1,40 1, 12 RSTN 500 2, 17 1,60 At 20,83 16,0 AgL
RSTN 630 3,05 1,76 1,4 1 RSTN 630 2,73 2,00 At 26,25 20,0 AgL
RSTN 800 3,83 2,22 1,77 RSTN 800 3,47 2,50 At 33,33 35,0 AgL
RSTN 1000 4,78 2,77 2,2 1 RSTN 1000 4,34 3,1 5 At - -
RSTN 1 100 5,20 3,0 1 2,4 1 RSTN 1 100 4,78 4,00 At - -
RSTN 1300 6, 15 3,56 2,85 RSTN 1300 5,65 4,00 At - -
RSTN 1600 7,58 4,38 3,5 1 RSTN 1600 6,95 5,00 At - -
RSTN 2000 9,47 5,48 4,38 RSTN 2000 8,69 6,30 At - -
RSTN 2500 1 1,87 6,87 5,50 RSTN 2500 10,86 8,00 At - -
RSTN 3000 14,05 8, 13 6,5 1 RSTN 3000 13,04 10,0 AgL - -

Available accessories: fully integrated ground screw terminal


A 1/2
A_TEIL_041014.qxd 14.10.2004 11:34 Seite 3

Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2


Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4
Single-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6

RSTN 50 – 3000
Design: Open frame, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw connection. The terminals are protected against finger
touch or contact with the back of the hand in compliance with accident prevention regulations (VBG 4). Ground connec-
tion via tab blade connection 6.3 x 0.8 mm. Accessory ground screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempera-
ture 40°C.
Available in stated voltages only, for other voltages please see identical design type REIA.

475/500/525 V 380/400/420 V 220/230/240 V 475/500/525 V 380/400/420 V 220/230/240 V


Power
Model 230 V 230 V 230 V 24 V 24 V 24 V
VA
Article no. Article no. Article no. Article no. Article no. Article no.
RSTN 50 50 1N–500–230–01 1N–400–230–01 1N–230–230–01 1N–500–024–01 1N–400–024–01 1N–230–024–01
RSTN 75 75 1N–500–230–02 1N–400–230–02 1N–230–230–02 1N–500–024–02 1N–400–024–02 1N–230–024–02
RSTN 100 100 1N–500–230–03 1N–400–230–03 1N–230–230–03 1N–500–024–03 1N–400–024–03 1N–230–024–03
RSTN 130 130 1N–500–230–04 1N–400–230–04 1N–230–230–04 1N–500–024–04 1N–400–024–04 1N–230–024–04
RSTN 200 200 1N–500–230–05 1N–400–230–05 1N–230–230–05 1N–500–024–05 1N–400–024–05 1N–230–024–05
RSTN 250 250 1N–500–230–06 1N–400–230–06 1N–230–230–06 1N–500–024–06 1N–400–024–06 1N–230–024–06
RSTN 320 320 1N–500–230–07 1N–400–230–07 1N–230–230–07 1N–500–024–07 1N–400–024–07 1N–230–024–07
RSTN 400 400 1N–500–230–08 1N–400–230–08 1N–230–230–08 1N–500–024–08 1N–400–024–08 1N–230–024–08
RSTN 500 500 1N–500–230–09 1N–400–230–09 1N–230–230–09 1N–500–024–09 1N–400–024–09 1N–230–024–09
RSTN 630 630 1N–500–230–10 1N–400–230–1 0 1N–230–230–10 1N–500–024–10 1N–400–024–10 1N–230–024–10
RSTN 800 800 1N–500–230–1 1 1N–400–230–1 1 1N–230–230–1 1 1N–500–024–1 1 1N–400–024–1 1 1N–230–024–1 1
RSTN 1000 1000 1N–500–230–12 1N–400–230–12 1N–230–230–12 – – –
RSTN 1 1 0 0 1100 1N–500–230–13 1N–400–230–13 1N–230–230–13 – – –
RSTN 1300 1300 1N–500–230–14 1N–400–230–14 1N–230–230–14 – – –
RSTN 1600 1600 1N–500–230–15 1N–400–230–15 1N–230–230–15 – – –
RSTN 2000 2000 1N–500–230–16 1N–400–230–16 1N–230–230–16 – – –
RSTN 2500 2500 1N–500–230–1 7 1N–400–230–17 1N–230–230–17 – – –
RSTN 3000 3000 1N–500–230–18 1N–400–230–18 1N–230–230–18 – – –

Copper Total Efficiency KB


Model Approx. dimensions in mm
weight weight ⬇ cos  = 0,5
kg kg % VA a b c d e f Attachment
RSTN 50 0,27 1,2 84 90 78 59 90 56 46 2x45 M4
RSTN 75 0,29 1,6 85 135 85 61 95 64 47 2x46 M4
RSTN 100 0,34 2, 1 86 225 85 75 95 64 61 2x53 M4
RSTN 130 0,45 2,3 90 300 96 77 104 84 61 50 M5
RSTN 200 0,58 2,9 92 490 96 87 104 84 70 54 M5
RSTN 250 0,66 3,7 92 690 96 100 104 84 84 61 M5
RSTN 320 0,73 4,5 92 850 105 101 111 84 85 62 M5
RSTN 400 1 ,03 5,2 93 1100 120 105 120 90 82 58 M5
RSTN 500 1 ,1 0 6,9 94 1510 120 121 120 90 102 69 M5
RSTN 630 1,68 7,8 94 1700 150 108 147 122 83 57 M6
RSTN 800 2,50 10,0 95 2550 150 125 147 122 101 65 M6
RSTN 1000 2,60 12,8 95 3750 150 151 147 122 127 78 M6
RSTN 1100 2,80 12,7 96 3550 174 129 154 135 97 63 M6
RSTN 1300 3,1 3 14,7 96 4390 174 139 154 135 105 68 M6
RSTN 1600 3,40 16,7 96 5400 174 149 154 135 116 73 M6
RSTN 2000 5,00 2 1,0 96 6600 195 156 175 150 125 73 M8
RSTN 2500 6,00 24,0 96 8000 195 172 175 150 146 85 M8
RSTN 3000 6,60 26,9 97 10800 195 184 175 150 152 87 M8

Standard stock items Subject to technical modifications

A 1/3
A_TEIL_041014.qxd 14.10.2004 11:34 Seite 4

Series RSTN UL-CSA


C
® -design (file no. E164203 M / for USA + Canada)
C
® 
In general
RSTN UL-CSA-transformers can be applied worldwide and meet national and international regulations. Following de-
signs are available:

Industrial control transformer UL 506 / CSA 22.2 approbated (sum total sec. voltages max. 250V)
Power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1, (50VA...1kVA), > 1kVA = special transformer
Control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2,
Isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4, (sec. 50V up to 500V max.)
Safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6, (sum total sec. voltages max. 50V)

Please state required design in your order.

Particular advantages of series RSTN UL-CSA:


- purchaser may select variable voltages
primary 110V…600V incl. +-5% tappings
secondary 12V...230V (see table below)
- high reliability and long service life
- compact construction and low weight
- low total losses, thus high efficiency
(for example reduction of core losses by two-way layering)
- higher than average output at short-time duty
- high performance in comparison to size
- control transformers feature higher value insulation system than regulation dictates
- high voltage stability because of small voltage drop between no-load and load
- from 130 VA upwards protected against short cut via insulating bushing
- mounting brackets comp. to DIN 41 307
- OPTIONALS: fully integrated ground screw terminal, screening and second output winding

Efficiency Examples Secondary Sec. fusing recommendation


Model Primary voltage
⬇ max. primary current in A voltage class CC / ATDR in A

% V 110V 380V 480V 575V V 24V 110V 230V


RSTN 50 UL-CSA 84 110 - 600 0,57 0,1 7 0,1 3 0, 1 1 1 2 - 230 2 0,5 0,25
RSTN 63 UL-CSA 84 110 - 600 0,72 0,2 1 0,1 6 0,1 3 1 2 - 230 2,5 0,5 0,25
RSTN 75 UL-CSA 85 110 - 600 0,84 0,24 0,1 9 0,1 6 1 2 - 230 3 0,8 0,5
RSTN 100 UL-CSA 86 110 - 600 1,09 0,32 0,25 0,2 1 1 2 - 230 4 1 0,5
RSTN 130 UL-CSA 90 110 - 600 1 ,37 0,40 0,32 0,27 1 2 - 230 5,6 1,13 0,8
RSTN 145 UL-CSA 91 110 - 600 1 ,5 1 0,44 0,35 0,29 24 - 230 5,6 1,25 0,8
RSTN 180 UL-CSA 91 110 - 600 1 ,87 0,55 0,43 0,36 24 - 230 7,5 1,6 0,8
RSTN 200 UL-CSA 92 110 - 600 2,08 0,6 1 0,48 0,40 24 - 230 8 1,8 0,8
RSTN 250 UL-CSA 92 110 - 600 2,57 0,75 0,59 0,50 24 - 230 10 2,25 1,13
RSTN 270 UL-CSA 92 110 - 600 2,77 0,8 1 0,63 0,53 24 - 230 12 2,5 1,25
RSTN 320 UL-CSA 92 110 - 600 3,29 0,96 0,76 0,63 24 - 230 15 3 1,4
RSTN 330 UL-CSA 93 110 - 600 3,35 0,99 0,78 0,65 24 - 230 15 3 1,5
RSTN 400 UL-CSA 93 110 - 600 4,07 1 ,1 8 0,94 0,78 24 - 230 17,5 3,5 1,8
RSTN 460 UL-CSA 93 110 - 600 4,68 1,36 1,00 0,84 24 - 230 20 4 2
RSTN 500 UL-CSA 94 110 - 600 5,07 1,48 1,1 6 0,97 24 - 230 20 4,5 2,25
RSTN 5 1 0 UL-CSA 94 110 - 600 5,1 9 1,5 1 1,1 8 0,99 24 - 230 20 4,5 2,25
RSTN 600 UL-CSA 94 110 - 600 6,08 1,77 1,38 1,1 5 24 - 230 25 5,6 2,8
RSTN 630 UL-CSA 94 110 - 600 6,38 1,86 1,45 1, 21 24 - 230 25 5,6 2,8
RSTN 700 UL-CSA 95 110 - 600 7,02 2,04 1,60 1,34 24 - 230 30 6,25 3
RSTN 800 UL-CSA 95 110 - 600 8,02 2,34 1,83 1,53 24 - 230 30 7,5 3,5
RSTN 1000 UL-CSA 95 110 - 600 10,02 2,92 2,28 1,90 110 - 230 - 9 4,5
RSTN 1 1 0 0 UL-CSA 96 110 - 600 12,03 3,1 8 2,48 2,07 110 - 230 - 10 5
RSTN 1300 UL-CSA 96 110 - 600 14,24 3,76 2,94 2,45 110 - 230 - 12 5,6
RSTN 1600 UL-CSA 96 110 - 600 17,55 4,63 3,62 3,02 110 - 230 - 15 7
RSTN 1900 UL-CSA 96 110 - 600 20,84 5,50 4,30 3,59 110 - 230 - 17,5 8
RSTN 2000 UL-CSA 96 110 - 600 2 1,94 5,79 4,53 3,78 110 - 230 - 20 9
RSTN 2500 UL-CSA 96 110 - 600 27,48 7,25 5,74 4,80 110 - 230 - 25 12
RSTN 3000 UL-CSA 97 110 - 600 29,43 8,58 6,72 5,6 1 110 - 230 - 30 15

Short-term delivery
A 1/4
A_TEIL_041014.qxd 14.10.2004 11:34 Seite 5

Industrial control transformers UL 506 / CSA 22.2 approbated


Single-phase power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1
Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2
Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4
Single-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6 C
® 
RSTN UL-CSA 50 – 3000
Design: Open frame, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw connection. The terminals are protected against finger
touch or contact with the back of the hand in compliance with accident prevention regulations UVV (VBG 4).
Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, approbated for insulation class A,
max. ambient temperature 40°C.
Preferential primary voltages are for example: 110/115/120V, 360/380/400V, 460/480/500V, 550/575/600V.

Copper Total Approx. dimensions in mm


Model Power Article no.
weight weight
VA app. kg app. kg a b c d e f Attach.
RSTN 50 UL-CSA 50 0317-00000050 0,27 1,20 78 59 90 56 45 45 M4
RSTN 63 UL-CSA 63 0317-00000063 0,28 1,47 78 69 90 56 54 50 M4
RSTN 75 UL-CSA 75 0317-00000075 0,29 1,60 85 63 95 64 47 47 M4
RSTN 100 UL-CSA 100 0317-00000100 0,34 2,1 0 85 75 95 64 61 53 M4
RSTN 130 UL-CSA 130 0317-00000130 0,45 2,30 96 77 104 84 61 50 M5
RSTN 145 UL-CSA 145 0317-00000145 0,52 2,20 85 83 95 64 70 58 M4
RSTN 180 UL-CSA 180 0317-00000180 0,53 3,00 105 80 11 1 84 62 51 M5
RSTN 200 UL-CSA 200 0317-00000200 0,58 2,90 96 87 1 14 84 70 54 M5
RSTN 250 UL-CSA 250 0317-00000250 0,66 3,70 96 100 1 14 84 84 61 M5
RSTN 270 UL-CSA 270 0317-00000270 0,63 3,50 105 88 11 1 84 70 55 M5
RSTN 320 UL-CSA 320 0317-00000320 0,73 4,50 105 101 11 1 84 85 62 M5
RSTN 330 UL-CSA 330 0317-00000330 1,00 4,1 5 120 88 120 90 70 53 M5
RSTN 400 UL-CSA 400 0317-00000400 1,03 5,20 120 103 120 90 82 58 M5
RSTN 460 UL-CSA 460 0317-00000460 1,1 0 6,00 120 110 120 90 90 63 M5
RSTN 500 UL-CSA 500 0317-00000500 1,1 0 6,90 120 121 120 90 102 69 M5
RSTN 510 UL-CSA 510 0317-00000510 1,60 6,45 135 106 133 104 87 58 M5
RSTN 600 UL-CSA 600 0317-00000600 1,70 7,00 135 116 133 104 97 63 M5
RSTN 630 UL-CSA 630 0317-00000630 1,68 7,80 150 108 147 122 83 57 M6
RSTN 700 UL-CSA 700 0317-00000700 1,80 7,90 135 123 133 104 107 68 M5
RSTN 800 UL-CSA 800 0317-00000800 2,50 10,00 150 125 147 122 101 65 M6
RSTN 1000 UL-CSA 1000 0317-00001000 2,60 12,80 150 151 147 122 127 78 M6
RSTN 1100 UL-CSA 1100 0317-00001100 2,80 1 2 ,70 174 129 154 135 97 63 M6
RSTN 1300 UL-CSA 1300 0317-00001300 3,1 3 1 4 ,70 174 139 154 135 105 68 M6
RSTN 1600 UL-CSA 1600 0317-00001600 3,40 1 6 ,70 174 149 154 135 116 73 M6
RSTN 1900 UL-CSA 1900 0317-00001900 4,00 2 1 ,1 0 174 169 154 135 136 83 M6
RSTN 2000 UL-CSA 2000 0317-00002000 4,50 22,50 195 156 175 150 125 73 M8
RSTN 2500 UL-CSA 2500 0317-00002500 6,00 24,60 195 172 175 150 146 85 M8
RSTN 3000 UL-CSA 3000 0317-00003000 6,60 26,90 195 184 175 150 152 87 M8

Short-term delivery
A 1/5
A_TEIL_041014.qxd 14.10.2004 11:34 Seite 6

Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2


Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4

RSTS 1200 – 8000


Design: Open frame, vertical design, stationary, for installation and set-up in dry rooms, separate windings, sturdy moun-
ting brackets. Connection to non-tracking transformer terminals with screw connection. Up to 20A the secondary
bridge contact can be plugged with a plain connector 6.3 x 0.8 mm. The terminals are protected against finger touch or
contact with the back of the hand in compliance with accident prevention regulations (VBG 4).
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempera-
ture 40°C.
Fusing recommendation: Below stated fusing recommendations refer to transformer's secondary side and safety fuse
cartridges comp. to IEC 127 / EN 60127 (A time-lag), or comp. to IEC 60269 (AgL). Concerning this and also for primary
fusing please observe paragraph 'Fusing', catalogue section 'In General'.

d e
Vertical design a b

Rated current input Current secondary and fusing recommendation

I 1 max. in I 1 max. in I 1 max. in I2 in Fusing I2 in Fusing


Model Model
A A A A A A A
pri. voltage ± 5% 230V 400V 500V sec. voltage 230V 115V
RSTS 1 200 5,72 3,30 2,65 RSTS 1 200 5,2 1 4 At 10,4 8 At
RSTS 1 500 7,00 4,00 3,30 RSTS 1 500 6,54 5 At 13,0 10 AgL
RSTS 1 800 8,1 8 4,94 3,95 RSTS 1 800 7,82 6,3 At 15,6 16 AgL
RSTS 2200 10,30 5,98 4,78 RSTS 2200 9,56 8 At 1 9, 1 16 AgL
RSTS 2500 1 1 ,70 6,70 5,43 RSTS 2500 10,80 8 At 2 1 ,7 20 AgL
RSTS 3000 14,00 7,90 6,49 RSTS 3000 13,00 10 AgL 26,0 20 AgL
RSTS 4200 19,70 11 ,40 9,1 2 RSTS 4200 18,20 16 AgL 36,5 35 AgL
RSTS 5000 23,70 13,70 10,90 RSTS 5000 21 ,70 20 AgL 43,4 50 AgL
RSTS 6300 30,00 17,50 13,80 RSTS 6300 27,30 25 AgL 54,7 50 AgL
RSTS 8000 38,20 22,1 0 17,60 RSTS 8000 34,70 35 AgL 69,5 63 AgL

KB Efficiency 475/500/525 V 380/400/420 V 220/230/240 V


Power
Model cos  0,5 ⬇ 230 V/115 V 230 V/115 V 230 V/115 V
VA
VA % Article no. Article no. Article no.
RSTS 1200 1200 3340 94, 1 0021–500–230–0 1 0022–400–230–0 1 0023–230–230–0 1
RSTS 1500 1500 4640 95,0 0021–500–230–02 0022–400–230–02 0023–230–230–02
RSTS 1800 1800 6000 95,5 0021–500–230–03 0022–400–230–03 0023–230–230–03
RSTS 2200 2200 7000 95,6 0021–500–230–04 0022–400–230–04 0023–230–230–04
RSTS 2500 2500 9075 95,8 0021–500–230–05 0022–400–230–05 0023–230–230–05
RSTS 3000 3000 10720 95,8 0021–500–230–06 0022–400–230–06 0023–230–230–06
RSTS 4200 4200 16720 96,4 0021–500–230–07 0022–400–230–07 0023–230–230–07
RSTS 5000 5000 20330 96,8 0021–500–230–08 0022–400–230–08 0023–230–230–08
RSTS 6300 6300 23450 97,0 0021–500–230–09 0022–400–230–09 0023–230–230–09
RSTS 8000 8000 25390 97,2 0021–500–230–1 0 0022–400–230–1 0 0023–230–230– 1 0

Copper Total
Approx. dimensions in mm
Model Size weight weight
app. kg app. kg a b c d e f Attachm.
RSTS 1200 UI 120/ 51 4,40 13,60 160 105 2 15 100 79 58 M 6
RSTS 1500 UI 120/ 61 4,50 15,00 160 115 2 15 100 89 63 M 6
RSTS 1800 UI 120/ 75 5,50 17,00 160 129 2 15 100 103 70 M 6
RSTS 2200 UI 150/ 52 6,60 21,00 200 122 262 124 94 58 M10
RSTS 2500 UI 150/ 65 7,20 24,80 200 135 262 124 107 65 M10
RSTS 3000 UI 150/ 77 7,60 28,00 200 147 262 124 119 71 M10
RSTS 4200 UI 150/ 92 9,20 31,00 200 162 262 124 134 78 M10
RSTS 5000 UI 150/103 12,90 38,50 200 173 262 124 145 83 M10
RSTS 6300 UI 180/ 78 16,80 48,00 240 168 360 144 140 - M10
RSTS 8000 UI 180/ 93 20,70 57,00 240 183 360 144 155 - M10

Subject to technical modifications Short-term delivery


A 1/6
A_TEIL_041014.qxd 14.10.2004 11:34 Seite 7

Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2


Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4

RSTL 1200 – 8000


Design: Open frame, horizontal design, stationary, for installation and set-up in dry rooms, separate windings, sturdy
mounting brackets. Connection to non-tracking terminal blocks with screw connection. The terminals are protected
against finger touch or contact with the back of the hand in compliance with accident prevention regulations (VBG 4).
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempera-
ture 40°C.

Fusing recommendation: Below stated fusing recommendations refer to transformer's secondary side and safety fuse
cartridges comp. to IEC 127 / EN 60127 (A time-lag), or comp. to IEC 60269 (AgL). Concerning this and also for primary
fusing please observe paragraph 'Fusing', catalogue section 'In General'.

c
e

d
Horizontal design a b

Rated current input Current secondary and fusing recommendation

I 1 max. in I 1 max. in I 1 max. in I2 in Fusing I2 in Fusing


Model Model
A A A A A A A
pri. voltage ± 5% 230V 400V 500V sec. voltage 230V 115V
RSTL 1 200 5,72 3,30 2,65 RSTL 1 200 5,2 1 4 At 10,4 8 At
RSTL 1 500 7,00 4,00 3,30 RSTL 1 500 6,54 5 At 13,0 10 AgL
RSTL 1 800 8,1 8 4,94 3,95 RSTL 1 800 7,82 6,3 At 15,6 16 AgL
RSTL 2200 10,30 5,98 4,78 RSTL 2200 9,56 8 At 1 9, 1 16 AgL
RSTL 2500 1 1 ,70 6,70 5,43 RSTL 2500 10,80 8 At 2 1 ,7 20 AgL
RSTL 3000 14,00 7,90 6,49 RSTL 3000 13,00 10 AgL 26,0 20 AgL
RSTL 4200 19,70 11 ,40 9,1 2 RSTL 4200 18,20 16 AgL 36,5 35 AgL
RSTL 5000 23,70 13,70 10,90 RSTL 5000 21 ,70 20 AgL 43,4 50 AgL
RSTL 6300 30,00 17,50 13,80 RSTL 6300 27,30 25 AgL 54,7 50 AgL
RSTL 8000 38,20 22,1 0 17,60 RSTL 8000 34,70 35 AgL 69,5 63 AgL

KB Efficiency 475/500/525 V 380/400/420 V 220/230/240 V


Power
Model cos  0,5 ⬇ 230 V/115 V 230 V/115 V 230 V/115 V
VA
VA % Article no. Article no. Article no.
RSTL 1200 1200 3340 94, 1 0024–500–230–0 1 0025–400–230–0 1 0026–230–230–0 1
RSTL 1500 1500 4640 95,0 0024–500–230–02 0025–400–230–02 0026–230–230–02
RSTL 1800 1800 6000 95,5 0024–500–230–03 0025–400–230–03 0026–230–230–03
RSTL 2200 2200 7000 95,6 0024–500–230–04 0025–400–230–04 0026–230–230–04
RSTL 2500 2500 9075 95,8 0024–500–230–05 0025–400–230–05 0026–230–230–05
RSTL 3000 3000 10720 95,8 0024–500–230–06 0025–400–230–06 0026–230–230–06
RSTL 4200 4200 16720 96,4 0024–500–230–07 0025–400–230–07 0026–230–230–07
RSTL 5000 5000 20330 96,8 0024–500–230–08 0025–400–230–08 0026–230–230–08
RSTL 6300 6300 23450 97,0 0024–500–230–09 0025–400–230–09 0026–230–230–09
RSTL 8000 8000 25390 97,2 0024–500–230–1 0 0025–400–230–1 0 0026–230–230–10

Copper Total
Approx. dimensions in mm
Model Size weight weight
app. kg app. kg a b c d e f Attachm.
RSTL 1200 UI 120/ 51 4,40 13,60 1 66 1 43 230 1 46 1 60 80 M6
RSTL 1500 UI 120/ 61 4,50 15,00 1 66 1 53 230 1 46 1 60 85 M6
RSTL 1800 UI 120/ 75 5,50 17,00 1 66 1 67 230 1 46 1 60 92 M6
RSTL 2200 UI 150/ 52 6,60 2 1,00 200 1 47 285 1 74 200 80 M6
RSTL 2500 UI 150/ 65 7,20 24,80 200 1 60 285 1 74 200 87 M6
RSTL 3000 UI 150/ 77 7,60 28,00 200 1 72 285 1 74 200 93 M6
RSTL 4200 UI 150/ 92 9,20 3 1,00 200 1 87 285 1 74 200 1 01 M6
RSTL 5000 UI 150/103 12,90 38,50 200 200 285 1 74 200 106 M6
RSTL 6300 UI 180/ 78 16,80 48,00 240 1 85 340 204 240 100 M8
RSTL 8000 UI 180/ 93 20,70 57,00 240 200 340 204 240 108 M8

Short-term delivery Subject to technical modifications

A 1/7
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 8

Series REIA
Miniaturized transformers

In general
REIA-transformers can be applied worldwide, meet national and international regulations and are ready for those up-
coming. Following designs are available:

Power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1, (15VA...1kVA), > 1kVA = special transformer
Control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2, (30VA and up)
Isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4, (sec. 50V up to 500V max.)
Safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6, (sum total sec. no-load voltages max. 50V)

Please state required design in your order.

Particular advantages of series REIA:


- purchaser may select variable voltages
(pri. 110V...600V) and (sec. 6V...600V max. 63A)
- high reliability and long service life
- compact construction and low weight
- low total losses, thus high efficiency
(for example reduction of core losses by two-way layering)
- higher than average output at short-time duty
- high performance in comparison to size
- control transformers feature higher value insulation system than regulation dictates
- high voltage stability because of small voltage drop between no-load and load
- from 130 VA upwards protected against short cut via insulating bushing
- temperature reserves, even at ta 60°C/B full current load possible
- mounting brackets comp. to DIN 41 307

Available accessories: fully integrated ground screw terminal Short-term delivery


A 1/8
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 9

Single-phase power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1


Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2
Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4
Single-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6

REIA 15 – 3000
Design: Open frame, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw connection. For currents above 20A terminal blocks with
screw connections may be used also. In this case dimensions b and c increase. The terminals are protected against fin-
ger touch or contact with the back of the hand in compliance with accident prevention regulations (VBG 4).
Standard design for translation up to max. 600 V resp. 20A.
Further designs available on request (voltages, currents, connections, mounting etc.).
Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempera-
ture 40°C.

f
Sek. Pri.

d e
a b

*) Copper Total Approx. dimensions in mm


Model Power Article no.
Size weight weight
VA app. kg app. kg a b c d e f Attachm.
REIA 15 15 EI 54/ 1 8 * 9–001–0 1 0,07 0,35 55 45 75 44 34 41 M3
REIA 18 18 EI 60/ 2 1 9–001–02 0,08 0,45 60 48 80 44 37 43 M3
REIA 30 30 EI 66/ 23 9–001–03 0,1 2 0,60 66 53 82 50 41 44 M4
REIA 40 40 EI 66/ 34 9–001–04 0,1 5 0,90 66 67 82 50 52 49 M4
REIA 50 50 EI 78/ 27 9–001–05 0,27 1,20 78 59 90 56 45 45 M4
REIA 63 63 EI 78/ 36 9–001–06 0,28 1,47 78 69 90 56 54 50 M4
REIA 75 75 EI 84/ 29 9–001–07 0,29 1,60 85 63 95 64 47 47 M4
REIA 100 100 EI 84/ 43 9–001–08 0,34 2,1 0 85 75 95 64 61 53 M4
REIA 140 140 EI 96/ 35 9–001–09 0,45 2,30 96 77 104 84 61 50 M5
REIA 145 145 EI 84/ 52 9–001–1 0 0,52 2,20 85 83 95 64 70 58 M4
REIA 180 180 EI 105/ 37 9–001–1 1 0,53 3,00 105 80 11 1 84 62 51 M5
REIA 200 200 EI 96/ 45 9–001–1 2 0,58 2,90 96 87 1 14 84 70 54 M5
REIA 250 250 EI 96/ 59 9–001–1 3 0,66 3,70 96 100 1 14 84 84 61 M5
REIA 270 270 EI 105/ 45 9–001–1 4 0,63 3,50 105 88 11 1 84 70 55 M5
REIA 300 300 EI 105/ 55* 9–001–1 5 0,65 4,00 105 98 103 84 80 60 M5
REIA 320 320 EI 105/ 60 9–001–1 6 0,73 4,50 105 101 11 1 84 85 62 M5
REIA 330 330 EI 120/ 4 1 9–001–1 7 1,00 4,1 5 120 88 120 90 70 53 M5
REIA 400 400 EI 120/ 53 9–001–1 8 1,03 5,20 120 103 120 90 82 58 M5
REIA 460 460 EI 120/ 6 1 9–001–1 9 1,1 0 6,00 120 110 120 90 90 63 M5
REIA 500 500 EI 120/ 73 9–001–20 1,1 0 6,90 120 121 120 90 102 69 M5
REIA 510 510 EI 135/ 52 9–001–21 1,60 6,45 135 106 133 104 87 58 M5
REIA 600 600 EI 135/ 62 9–001–22 1,70 7,00 135 116 133 104 97 63 M5
REIA 630 630 EI 150N/49 9–001–23 1,68 7,80 150 108 147 122 83 57 M6
REIA 700 700 EI 135/ 72 9–001–24 1,80 7,90 135 123 133 104 107 68 M5
REIA 800 800 EI 150N/66 9–001–25 2,50 10,00 150 125 147 122 101 65 M6
REIA 1000 1000 EI 150N/92 9–001–26 2,60 12,80 150 151 147 122 127 78 M6
REIA 1100 1100 EI 174/ 62 9–001–27 2,80 1 2 ,70 174 129 154 135 97 63 M6
REIA 1300 1300 EI 174/ 72 9–001–28 3,1 3 1 4 ,70 174 139 154 135 105 68 M6
REIA 1600 1600 EI 174/ 82 9–001–29 3,40 1 6 ,70 174 149 154 135 116 73 M6
REIA 1900 1900 EI 174/102 9–001–30 4,00 2 1 ,1 0 174 169 154 135 136 83 M6
REIA 2000 2000 EI 192/ 82 9–001–3 1 4,50 22,50 195 156 175 150 125 73 M8
REIA 2200 2200 EI 192/ 92* 9–001–32 5,50 23,80 195 166 168 150 134 78 M8
REIA 2500 2500 EI 192/104 9–001–33 6,00 24,60 195 172 175 150 140 85 M8
REIA 3000 3000 EI 192/ 110 9–001–34 6,60 26,90 195 184 175 150 152 87 M8

Short-term delivery *) Models without integral attachment bar Subject to technical modifications

A 1/9
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 10

Series URST
Universal control transformers

In general
We recommend universal control transformers in cases of cramped storage space combined with the need for high
variety, making the use of many diverse single-phase control transformers insensible.
The multiple choices in primary connection (200...550V) for different mains input voltages featured by universal control
transformers, do not allow as optimal a design as control transformers series RSTN or REIA. And bearing the higher
purchase price in mind, one should consider prior to ordering, whether applying universal control transformers is ne-
cessary, since we guarantee short-term deliveries for special makes also.
Regulations and instructions for single-phase control transformers regarding mechanical and electrical requirements
are valid for universal control transformers also. The main difference to single-phase control transformers, apart from
the wide range of primary voltages, is the extended secondary range. The provided 2 - 6 output voltages increase ap-
plication possibilities even further. On output-side, only the current allocated to each winding section may flow in each
connection mode (parallel connection 2 x rated current, series connection 1 x rated current).
When this rule is observed, further output voltages can be drawn apart from those stated. However, the rated output
for the size in question is no longer achieved in such cases.
Therefore, this solution recommends itself only in individual cases where a different voltage has to be made available
quickly.
URST-transformers can be applied worldwide, meet national and international regulations and are ready for those up-
coming. Following design is available:
Control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2

Particular advantages of series URST:


- high reliability and long service life
- variable input voltage (200V...550V)
- extended secondary range
- compact construction and low weight
- low total losses, thus high efficiency
(for example reduction of core losses by two-way layering)
- higher than average output at short-time duty
- high performance in comparison to size
- high voltage stability because of small voltage drop between no-load and load
- from 130 VA upwards protected against short cut via insulating bushing
- temperature reserves, even at ta 60°C/B full current load possible
- mounting brackets comp. to DIN 41 307
- stock items

Fusing recommendation:
Below stated fusing recommendations refer to transformer's secondary side and safety fuse cartridges comp. to IEC 127
/ EN 60127 (A time-lag) or comp. to IEC 60269 (AgL). Concerning this and also for primary fusing please observe para-
graph 'Fusing', catalogue section 'In General'.

Rated current input Current secondary and fusing recommendation

I 1 max. in I 1 max. in I2 in Fusing I2 in Fusing I2 in Fusing I2 in Fusing


Model Model
A A A A A A A A A A
pri. voltage 200V 550V sec. voltage 115V 230V 24-30V (Parallel) 48-60V (Series)
URST 100 0,50 0,20 URST 100 0,86 0,63At 0,43 0,315At 3,33 2,50At 1 ,66 1 ,25At
URST 160 0,82 0,30 URST 160 1,39 1 ,00At 0,69 0,50At 5,33 4,00At 2,66 2,00At
URST 250 1 ,30 0,50 URST 250 2,1 7 1 ,60At 1,08 0,80At 8,33 6,30At 4,1 6 3,1 5At
URST 320 1 ,70 0,60 URST 320 2,78 2,00At 1,39 1,00At 10,66 8,00At 5,33 4,00At
URST 400 2,05 0,75 URST 400 3,47 2,50At 1,73 1,25At 13,33 10,0AgL 6,66 5,00At
URST 500 2,60 0,95 URST 500 4,34 3,1 5At 2, 17 1,60At 16,66 16,0AgL 8,33 6,30At
URST 630 3,25 1 ,20 URST 630 5,47 4,00At 2,73 2,00At 20,00 16,0AgL 10,50 8,00At
URST 800 4,1 0 1 ,50 URST 800 6,95 5,00At 3,47 2,50At 26,66 20,0AgL 13,33 10,0AgL
URST 1000 5,1 0 1 ,90 URST 1000 8,69 6,30At 4,34 3,1 5At 33,33 35,0AgL 16,66 16,0AgL
URST 1600 8,1 0 3,00 URST 1600 13,9 1 1 0,00At 6,95 5,00At - - - -
URST 2500 13,00 5,00 URST 2500 21,73 20,00At 10,86 8,0AgL - - - -
Subject to technical modifications Standard stock items
A 1/10
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 11

Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2

URST 100 – 2500


Design: Open frame, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw- and tab connection 2.8 x 0.8 mm up to 5 A, and 6.3 x 0.8
mm up to 20A. According to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up to 5 A, and 6.3 x 0.8 up to 20
A. Above 20A terminal blocks with screw connections are used. The terminals are protected against finger touch or con-
tact with the back of the hand in compliance with accident prevention regulations (VBG 4).
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempera-
ture 40°C.

Voltage series:
Interchangeable input connections:
200/220/230/250/270/280/330/350/370/380/390/400/420/430/440/450/470/490/500/550V
Interchangeable output connections:
115/230V resp. 21/24/30//42/48/60V
Corresponding to connection diagram on rating plate, transformers are to be operated partly in parallel- or series con-
nection.

d e
a b

KB Efficiency 200..550 V 200...550 V


Power
Model cos  0,5 ⬇ 115/230 V 21/24/30 V
VA
VA % Article no. Article no.
URST 100 100 225 88 4–550–230–0 1 4–550–030–0 1
URST 160 160 640 92 4–550–230–02 4–550–030–02
URST 250 250 800 93 4–550–230–03 4–550–030–03
URST 320 320 1 1 00 93,5 4–550–230–04 4–550–030–04
URST 400 400 1 250 94 4–550–230–05 4–550–030–05
URST 500 500 1 700 94,5 4–550–230–06 4–550–030–06
URST 630 630 2550 95 4–550–230–07 4–550–030–07
URST 800 800 3550 95,5 4–550–230–08 4–550–030–08
URST 1000 1000 4400 96 4–550–230–09 4–550–030-09
URST 1600 1600 5300 96 4–550–230– 1 0 -
URST 2500 2500 9000 97 4–550–230– 1 1 -

Copper Total
Model Approx. dimensions in mm
weight weight

app. kg app. kg a b c d e 2xf Attachment


URST 100 0,45 2,00 85 76 85 64 61 2x48 M4
URST 160 0,75 3,80 105 88 103 84 70 2x56 M5
URST 250 0,80 4,50 120 88 114 90 71 2x54 M5
URST 320 1,30 5,30 120 100 114 90 82 2x60 M5
URST 400 1,50 6,00 120 106 114 90 90 2x64 M5
URST 500 1,90 7,80 150 108 138 122 87 2x59 M6
URST 630 2,80 10,10 150 125 138 122 101 2x66 M6
URST 800 2,90 14,30 174 129 148 135 97 2x64 M6
URST 1000 3,20 15,70 174 138 148 135 107 2x69 M6
URST 1600 7,00 25,00 205 154 168 150 124 2x74 M8
URST 2500 10,00 32,40 205 172 168 150 141 2x82 M8

Standard stock items Subject to technical modifications

A 1/11
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 12

Series RSST
Anti-interference transformers with special screening

In general
RSST-transformers can be applied worldwide, meet national and international regulations and are ready for those up-
coming. Following designs are available:
Control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2,
Isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4,

Particular advantages of series RSST:


- high reliability and long service life
- compact construction and low weight
- wide band interference pulse suppression
- low total losses, thus high efficiency
(for example reduction of core losses by two-way layering)
- higher than average output at short-time duty
- high performance in comparison to size
- high voltage stability because of small voltage drop between no-load and load
- voltage adaptation via +-5% taps
- from 130 VA upwards protected against short cut via insulating bushing
- temperature reserves, even at ta 60°C/B full current load possible
- mounting brackets comp. to DIN 41 307
- stock items

Transmission loss, example model RSST 200

Available accessories: fully integrated ground screw terminal Standard stock items
A 1/12
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 13

Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2


Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4

RSST 100 – 1000


In general: Riedel anti-interference control transformers guarantee excellent, wide band interference voltage suppres-
sion of both symmetrical and asymmetrical factors.
The graph on previous page shows a typical suppression progress dependent on frequency, as an example portrayed
by anti-interference control transformer RSST 200. Its' special sreening increases the standard high-frequency trans-
mission loss of a 50 Hz transformer by about 20 dB. The special shielding of high permeability is a protected develop-
ment by our company. Not only can it be applied in the active anti-interference transformer but also to increase sup-
pression in all other products using a transformer with indirect-coupled windings.
Design: Open frame, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw- and tab connection 2.8 x 0.8 mm up to 5 A, and 6.3 x 0.8
mm at higher current. According to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up to 5 A, and 6.3 x 0.8 up
to 20 A. The terminals are protected against finger touch or contact with the back of the hand in compliance with accident
prevention regulations (VBG 4). Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground screw con-
nection terminal available.
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempe-
rature 40°C.

Fusing recommendation:
Below stated fusing recommendations refer to transformer's secondary side and safety fuse cartridges comp. to IEC
127 / EN 60127 (A time-lag). Concerning this and also for primary fusing please observe paragraph 'Fusing', catalogue
section 'In General'.
Rated current input Current secondary and fusing recommendation

I 1 max. in I2 in Fusing
Model Model
A A A
pri. voltage 220/230/240 V sec. voltage 230V
RSST 100 0,52 RSST 100 0,43 0,315 At
RSST 130 0,65 RSST 130 0,56 0,40 At
RSST 200 1 ,00 RSST 200 0,86 0,63 At
RSST 250 1 ,23 RSST 250 1,08 0,80 At
RSST 320 1 ,57 RSST 320 1,39 1,00 At
RSST 400 1 ,94 RSST 400 1, 73 1,25 At
RSST 500 2,42 RSST 500 2, 17 1,60 At
RSST 630 3,05 RSST 630 2,73 2,00 At
RSST 800 3,83 RSST 800 3,47 2,50 At
RSST 1000 4,78 RSST 1000 4,34 3,1 5 At

Copper Total 220/230/240 V Efficiency KB


Model Size Approx. dimensions in mm
weight weight 230 V ⬇ cos  = 0,5
VA app. kg app. kg Article no. % VA a b c d e f Attachment
RSST 100 100 0,34 2, 1 47–230–230–0 1 86 225 85 75 95 64 61 2x53 M4
RSST 130 130 0,45 2,3 47–230–230–02 90 300 96 77 104 84 61 50 M5
RSST 200 200 0,58 2,9 47–230–230–03 92 490 96 87 104 84 70 54 M5
RSST 250 250 0,66 3,7 47–230–230–04 92 690 96 100 104 84 84 61 M5
RSST 320 320 0,73 4,5 47–230–230–05 92 850 120 101 111 84 85 62 M5
RSST 400 400 1,03 5,2 47–230–230–06 93 1 1 00 120 105 120 90 82 58 M5
RSST 500 500 1,1 0 6,9 47–230–230–07 94 1 51 0 120 121 120 90 102 69 M5
RSST 630 630 1,68 7,8 47–230–230–08 94 1700 150 108 147 122 83 57 M6
RSST 800 800 2,50 10,0 47–230–230–09 95 2550 150 125 147 122 101 65 M6
RSST 1000 1000 2,60 12,8 47–230–230–1 0 95 3750 150 151 147 122 127 78 M6

Standard stock items Other voltages on request Subject to technical modifications

A 1/13
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 14

Single-phase power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1


Single-phase control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2
Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4
Single-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6

RUE 280 – 20000


In general:
RUE-transformers can be applied worldwide, meet national and international regulations and are ready for those upco-
ming. Choose from following designs:
Power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1, (280VA...1kVA), > 1kVA = special transformer
Control transformers comp. to VDE 0570 part 2-2, EN 61558-2-2, (280VA and up)
Isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4, (sec. 50V and up)
Safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6, (sum total sec. no-load voltages max. 50V)

Please state required design in your order.

Design:
Open frame, vertical design, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting
brackets. Connection to non-tracking transformer terminals with screw connection. Above 20A transformer terminal
blocks or terminal blocks with screw connections are used, (dimensions b1 and c1 increase). The terminals are pro-
tected against finger touch or contact with the back of the hand in compliance with accident prevention regulations
(VBG 4).
Standard design for translation up to max. 550 V resp. 65A.
Further designs available on request (voltages, currents, connections, mounting etc.).

IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempe-
rature 40°C.
Below stated dimensions and weights may show currently valid standards only. They remain subject to change.

c c1

d e
a b
b1

Copper Total
Power Approx. dimensions in mm
Model Size Article no. weight weight
VA
app. kg app. kg a b b1 c c1 d e Attachm.
RUE 280 280 UI 75 / 4 1 0059-00000280 0,95 3,60 100 81 98 1 32 197 63 64 M 5
RUE 630 630 UI 90/ 5 1 0059-00000630 1 ,65 6,30 120 95 113 1 57 222 76 76 M 6
RUE 980 980 UI 102 / 57 0059-00000980 2,50 7,70 140 103 117 1 77 242 76 87 M 6
RUE 1200 1200 UI 120 / 5 1 0059-0000 1200 4,40 13,60 160 105 117 208 273 100 79 M 6
RUE 1400 1400 UI 114 / 64 0059-0000 1400 3,50 13,00 154 1 14 129 1 98 263 100 95 M 6
RUE 1500 1500 UI 120 / 6 1 0059-0000 1500 4,50 15,00 160 1 15 1 27 208 273 100 89 M 6
RUE 1800 1800 UI 120 / 75 0059-0000 1800 5,50 17,00 160 129 141 208 273 100 103 M 6
RUE 2000 2000 UI 132 / 72 0059-00002000 5,85 20,00 178 132 143 228 293 11 2 102 M 8
RUE 2200 2200 UI 150 / 52 0059-00002200 6,60 21 ,00 200 122 128 260 325 124 94 M 8
RUE 2500 2500 UI 150 / 65 0059-00002500 7,20 24,80 200 135 141 260 325 124 107 M 8
RUE 3000 3000 UI 150 / 77 0059-00003000 7,60 28,00 200 147 153 260 325 124 1 19 M 8
RUE 4200 4200 UI 150 / 92 0059-00004200 9,20 31 ,00 200 162 168 260 325 124 134 M 8
RUE 5000 5000 UI 150 /103 0059-00005000 12,90 38,50 200 173 180 260 325 124 145 M 8
RUE 6000 6000 UI 168 / 92 0059-00006000 15,00 42,00 228 172 175 287 352 136 144 M 8
RUE 6300 6300 UI 180 / 78 0059-00006300 16,80 48,00 240 168 168 305 370 144 140 M 8
RUE 8000 8000 UI 180 / 93 0059-00008000 20,70 57,00 240 183 183 305 370 144 155 M 8
RUE 10000 10000 UI 210 / 88 0059-000 10000 29,1 0 78,00 280 188 188 360 425 176 158 M10
RUE 13000 13000 UI 210 /103 0059-000 13000 33,00 89,00 280 203 203 360 425 176 173 M10
RUE 16000 16000 UI 210 /133 0059-000 16000 4 1,90 1 1 2,00 280 233 233 360 425 176 203 M10
RUE 20000 20000 UI 240/140 0059-00020000 42,00 129,00 320 250 250 41 0 475 196 21 4 M14
Subject to technical modifications Short-term delivery
A 1/14
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 15

Single-phase high-power transformers comp. to VDE 0532

REST 20 – 120
In general:
The rectangular core stacks of our single-phase high-power transformers are made of two-layered grain-oriented
low-loss strips. The windings consist of high-grade insulated double-lacquered massive copper. Core and windings
are vacuum impregnated together and subsequently baked in the drying oven for several hours.
The transformer's electrical design ensures best possible efficiency and a temperature rise remaining far below the li-
mits specified in regulation VDE. A sound design guarantees almost unlimited service life even at occurring overload.
REST-transformers can be applied worldwide, meet national and international regulations and are ready for those up-
coming. Following design is available:
High-power transformers comp. to VDE 0532
Design:
Open frame, vertical design, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting
brackets. Connection to robust terminal blocks (up to 450 A) resp. studs, line bars or cable lugs (not measured). Maxi-
mal voltage (phase-phase) 2000V.
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, max. ambient temperature 40°C.
Insulation class F (average value temperature 140°C)
Attention: higher thermal load at lower efficiency
Because each high power transformer is individually designed, below stated dimensions and weights may show the
currently valid state only and remain subject to modification.

We manufacture single-phase high-power transformers in all requested protection classes up to IP 65.


All types may be delivered as single-phase auto-transformers also (please find calculation method in section 'transformers
in economy winding', catalogue part 'In General').

* depending on design and winding type of special currents all measurement may vary, especial-
ly measurement b may enlarge up to 100mm!
Measurment d and e on request

Copper Total Approx. dimensions in mm


Power
Model Article no. weight weight
kVA
app. kg app. kg a b* c c1 up to 63A
REST 20 20,0 0058-00-00020 on request 1 40 360 240 420 c + 100
REST 25 25,0 0058-00-00025 on request 1 70 360 260 420 c + 100
REST 30 30,0 0058-00-00030 on request 200 360 265 420 c + 100
REST 40 40,0 0058-00-00040 on request 250 360 265 460 c + 100
REST 50 50,0 0058-00-00050 on request 300 400 260 570 c + 150
REST 63 63,0 0058-00-00063 on request 340 400 290 570 c + 150
REST 80 80,0 0058-00-00080 on request 380 400 300 570 c + 150
REST 100 100,0 0058-00-00 1 00 on request 460 440 320 620 c + 150
REST 120 120,0 0058-00-00 1 20 on request 580 520 360 660 c + 150

Short-term delivery Higher powers on request Subject to technical modifications

A 1/15
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 16

Single-phase auto transformers comp. to VDE 0570 part 2-13, EN 61558-2-13

RLTS 80 – 900
Single-phase auto transformers for single-phase fan-motors
In general: Transformers series RLTS are single-phase auto transformers featuring 7 stages and were specially desi-
gned for air conditioning and air engineering. Following design is available:
Auto transformers comp. to VDE 0570

Design: Open frame, stationary, for installation and set-up in dry rooms, economy winding, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw- and tab connection 2.8 x 0.8 mm up to 5 A, and 6.3 x 0.8
mm up to 20A. According to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up to 5 A, and 6.3 x 0.8 up to
20 A. Above 20A terminal blocks with screw connections are used. The terminals are protected against finger touch or
contact with the back of the hand in compliance with accident prevention regulations (VBG 4).
Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23 with natural cooling, insulation class E, max. ambient tempe-
rature 40°C.

Voltage range: Input voltage: 230 V


Output voltages: 80/100/125/150/175/190/230 V

Special design: Series RLTS is also available in housing protection class IP 23 with following option:
Option: multicontact switch, operation indication lamp, housing etc.
(prices on request).

Further designs available on request (voltages, currents, connections, mounting etc.).

Copper Total
Model Current Article no. Approx. dimensions in mm
weight weight

A app. kg app. kg a b c d e f Attachment


RLTS 80 1,45 50–230–0 1 0,28 1,47 78 67 80 56 54 47 M4
RLTS 115 2,1 0 50–230–02 0,35 2,00 85 75 85 64 61 53 M4
RLTS 220 4,00 50–230–03 0,63 3,50 105 86 103 84 70 53 M5
RLTS 410 7,50 50–230–04 1,1 0 5,50 120 105 112 90 82 58 M5
RLTS 600 1 1 ,00 50–230–05 1,80 8,00 150 108 136 122 83 57 M6
RLTS 710 13,00 50–230–06 2,60 10,00 150 130 136 122 101 65 M6
RLTS 900 16,50 50–230–07 2,80 13,50 150 156 136 122 127 78 M6
RLTS 1090 20,00 50–230–08 2,90 13,1 0 174 129 149 135 96 63 M6
RLTS 1310 24,00 50–230–09 3,50 17,50 174 149 149 135 116 73 M6
RLTS 1745 32,00 50–230– 10 4,00 21,1 0 174 169 149 135 136 83 M6
Subject to technical modifications Short-term delivery
A 1/16
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 17

Single-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4


Single-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6

RGTT 500 – 3000


Portable transformers
In general: Single-phase isolation transformers RGTT are compounded into non-hygroscope plastic cases specially de-
signed for the electrical industry. They are shock resistant and self-extinguishing.
The unit's input features a 230V supply line (2 m long) inclusive plug, an inrush current limitation and an exchangeable
external fuse.
The output is equipped with an earthing contact socket called Schuko (230V) or an attachment socket type CEE. Out-
put current drains are dictated by CEEform regulation DIN VDE 0623, EN 60309.

Attention: Earthing contact primary and secondary not connected!

Design secondary up to 25V 50/60Hz max. 32A


Design secondary up to 110V 50/60Hz max. 32A
Design secondary up to 230V 50/60Hz max. 16A
Please state secondary voltage in your order also.
Design: IP 44 when Schuko-socket, IP 65 when CEE-socket, protection class II, max. ambient temperature 40°C.

Design secondary output:


Model sec. up to 25 V sec. up to 50 V sec. up to 110 V sec. 230 V sec. 230 V
RGTT 250 1 x CEE 32A 1 x CEE 16A 1 x CEE 16A 1 x CEE 16A 1 x Schuko 16A
RGTT 500 1 x CEE 32A 1 x CEE 16A 1 x CEE 16A 1 x CEE 16A 1 x Schuko 16A
RGTT 800 1 x CEE 32A 1 x CEE 16A 1 x CEE 16A 1 x CEE 16A 1 x Schuko 16A
RGTT 1000 2 x CEE 32A 1 x CEE 32A 1 x CEE 16A 1 x CEE 16A 1 x Schuko 16A
RGTT 1600 – 2 x CEE 32A 1 x CEE 16A 1 x CEE 16A 1 x Schuko 16A
RGTT 2000 – 2 x CEE 32A 1 x CEE 32A 1 x CEE 16A 1 x Schuko 16A
RGTT 2500 – 2 x CEE 32A 1 x CEE 32A 1 x CEE 16A 1 x Schuko 16A
RGTT 3000 – 2 x CEE 32A 1 x CEE 32A 1 x CEE 16A 1 x Schuko 16A

Model Power Article no. Article no. Copper Total Approx. dimensions in mm
weight weight
VA 24V-230V (CEE) 230V (Schuko) kg kg a b c
RGTT 250 250 0010-60020-00 0011-60021-00 0,65 7,5 166 250 219
RGTT 500 500 0010-60020-0 1 0011-60021-0 1 1,10 10,0 166 250 219
RGTT 800 800 0010-60020-02 0011-60021-02 2,50 14,5 192 276 259
RGTT 1000 1000 0010-60020-03 0011-60021-03 2,60 1 7,5 192 276 259
RGTT 1600 1600 0010-60020-04 0011-60021-04 3,40 23,0 340 265 280
RGTT 2000 2000 0010-60020-05 0011-60021-05 5,00 3 1,5 340 265 280
RGTT 2500 2500 0010-60020-06 0011-60021-06 6,00 34,0 340 265 280
RGTT 3000 3000 0010-60020-07 0011-60021-07 6,60 37,5 340 265 280

Short-term delivery Subject to technical modifications

A 1/17
A_TEIL_041014.qxd 14.10.2004 11:35 Seite 18
B
Copyright: Deutsche Bundesbahn/Riedel Product group

The safety of rail traffic and the punctuality of trains are of prime
importance to German Rail. Extensive electric and electronic
switch plants guarantee smooth running around the clock.
German Rail cannot afford breakdowns in its power supply – a
good reason to apply Riedel products.
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 2

Three-phase transformers

Load capacity of neutral point (star point):


Regarding neutral point load capacity of three-phase transformers, observe below following to avoid additional losses
and neutral point shifting:
Star-star connection:
The neutral point may only be loaded with full rated current (line-to-line current), when neutral conductor of sup-
ply line is connected rigidly to primary neutral point of transformer. Otherwise, neutral point may only be loaded
with app. 10% line-to-line current.
The same rule applies for three-phase auto transformers in star-economy design.
Taking no special measures, following connection modes amount to 100% load of neutral point:
Delta-star connection with secondary extended neutral point Dy5
Star-zigzag connection with secondary extended neutral point Yz5
If three-phase sets are formed via 3 single-phase transformers, then load of neutral point must definitely be avoided.

Vector groups Designation Secondary


Vector diagram Circuit configuration
Code no. Vector group star point
The vector group marks the circui-
try of windings and their phase po-
sition to each other. It consists of a
capital and small letter plus a code none

number.
10% load
The capital letter refers to the input capacity
winding, the small to the output
winding. The upper voltage is mar-
ked by 1 in front, the undervoltage full load
capacity
by a 2 in front, regardless of input-
or output voltage. A 1 in back on the
contrary, marks the beginning of a
full load
winding, a 2 in back the end. Tabs capacity
are marked 3 and 4 in back. The
numbers correlate to letters U V W
and distinguish the 3 phases. The none
neutral point (star point) is always
marked N. full load
capacity
The most common vector groups
are summarized alongside, input
left-hand, output right-hand.
Unless otherwise requested, none

three-phase transformers are pre-


ferentially delivered in star-star 10% load
connection. capacity

If on secondary side, in relation to


the primary side, higher currents at full load
capacity
smaller voltages are needed, pre-
ferentially Yd5 / Yd11 is used be-
cause of the winding cross sec-
full load
tions. capacity

none

full load
capacity

10% load
capacity
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 1

Single-phase auto transformers comp. to VDE 0570 part 2-13, EN 61558-2-13

RDLTS 95 – 1800
Single-phase auto transformers in V-circuit arrangement for three-phase fan-motors
(1 set consisting of 2 individual transformers)
In general: Transformers series RDLTS are single-phase auto transformers featuring 5 stages and were specially desi-
gned for air conditioning and air engineering. Following design is available:
Auto transformers comp. to VDE 0570
Design: Open frame, stationary, for installation and set-up in dry rooms, economy winding, sturdy mounting brackets.
Connection to non-tracking transformer terminals with screw- and tab connection 2.8 x 0.8 mm up to 5 A, and 6.3 x 0.8
mm up to 20A. According to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up to 5 A, and 6.3 x 0.8 up to 20
A. Above 20A terminal blocks with screw connections are used. The terminals are protected against finger touch or con-
tact with the back of the hand in compliance with accident prevention regulations (VBG 4).
Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23 with natural air self-cooling, insulation class E, max. ambient
temperature 40°C.
Voltage range: Input voltage: 400V 3~
Output voltages: 140/180/230/280/400V
Special design: Series RDLTS is also available in housing protection class IP 23 with following option:
Option: multicontact switch, operation indication lamp, housing etc.
(prices on request).
Further designs available on request (voltages, currents, connections, mounting etc.).

V-circuit:

Copper Total
Model Current Article no. Approx. dimensions in mm
weight weight

A kg/set kg/set a b c d e f Attachment


RDLTS 95 1,0 51–400–0 1 0,6 4,0 78 67 80 56 54 47 M 4
RDLTS 190 2,0 51–400–02 1,4 6,8 105 78 103 84 62 49 M 4
RDLTS 285 3,0 51–400–03 1,8 7,8 105 86 103 84 70 53 M 4
RDLTS 380 4,0 51–400–04 2,2 13,0 120 93 11 2 90 70 52 M 5
RDLTS 475 5,0 51–400–05 4,0 14,6 120 105 112 90 82 58 M 5
RDLTS 660 7,0 51–400–06 7,1 17,1 150 108 136 122 83 57 M 6
RDLTS 950 10,0 51–400–07 10,9 20,2 150 124 136 122 101 65 M 6
RDLTS 1330 14,0 51–400–08 12,4 28,4 174 139 149 135 106 68 M 6
RDLTS 1800 19,0 51–400–09 18,0 40,1 174 169 149 135 136 83 M 6
RDLTS 2465 26,0 51–400–1 0 23,0 44,0 195 175 188 150 110 68 M 8
RDLTS 3410 36,0 51–400–1 1 36,0 58,0 231 182 218 180 114 68 M 10

Short-term delivery Subject to technical modifications

B 1/1
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 2

Three-phase power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1


Three-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4
Three-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6

DRUE 50 - 36000 (Insulation class E)


DRUF 6000 - 40000 (Insulation class F)
In general: Transformers DRUE and DRUF can be applied worldwide, meet national and international regulations and
are ready for those upcoming. Choose from following designs:
Power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1, (50VA...1kVA), < 1kVA = special transformer
Isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4, (sec. 50V and up)
Safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6, (sum total sec. no-load voltages max. 50V)

Please state required design in your order.

Design: Open frame, vertical design, stationary, for installation and set-up in dry rooms, separate windings, sturdy
mounting brackets. Connection to non-tracking transformer terminals with screw connection. Above 60A non-trak-
king terminal blocks are mounted on head angles (attention: dimensions b and c will increase, not stated below). The
terminals are protected against finger touch or contact with the back of the hand in compliance with accident preven-
tion regulations (VBG 4).
Standard design for translation up to max. 550 V resp. 105A.
Further designs available on request (voltages, currents, connections, mounting etc.).
IP 00, suitable for installation up to protection rating IP 23 with natural air self-cooling, max. ambient temperature 40°C.
Insulation class E (average value temperature 115°C)
Insulation class F (average value temperature 140°C)
Attention: Higher thermal stress at lower efficiency

We manufacture these three-phase miniaturized transformers in all requested protection classes up to IP 65.

All types are also available as three-phase auto transformers (please find calculation method in catalogue section 'In gene-
ral', paragraph 'Transformers in economy winding').
Preferential circuitry: YNyn0; Dyn 5; Yd5

Model with transformer terminals - usually up to 60A

Model with terminal blocks - above 60A

Subject to technical modifications Short-term delivery


B 1/2
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 3

Three-phase power transformers comp. to VDE 0570 part 2-1, EN 61558-2-1


Three-phase isolation transformers comp. to VDE 0570 part 2-4, EN 61558-2-4
Three-phase safety transformers comp. to VDE 0570 part 2-6, EN 61558-2-6

DRUE 50 – 36000 (insulation class E)


DRUF 6000 – 40000 (insulation class F)
All types are also available as three-phase auto transformers (please find calculation method in catalogue section 'In gene-
ral', paragraph 'Transformers in economy winding').

Design insulation class E

Copper Total
Model Power ⬇ Core Article no. Approx. dimensions in mm
weight weight

VA % kg kg a b c d e Attach.
DRUE 50 50 85,0 3 UI 48/ 26 13–000–01 E 0,22 1 ,2 96 86 100 71 48 M 4
DRUE 110 110 86,0 3 UI 60/ 21 13-000-02 E 0,7 1 ,7 120 81 1 10 90 39 M 4
DRUE 150 150 87,0 3 UI 60/ 31 13-000-03 E 0,8 2,4 120 91 11 0 90 49 M 4
DRUE 260 260 91,0 3 UI 75/ 26 13-000-04 E 1,1 3,9 150 86 135 11 3 49 M 5
DRUE 4 10 410 92,0 3 UI 75/ 41 13-000-05 E 1,5 5,7 150 10 1 135 11 3 64 M 5
DRUE 500 500 92,5 3 UI 90/ 31 13-000-06 E 2,2 6,6 180 91 155 136 57 M 6
DRUE 630 630 93,5 3 UI 90/ 41 13-000-07 E 2,5 8,4 180 101 155 136 67 M 6
DRUE 800 800 94,0 3 UI 90/ 51 13-000-08 E 2,8 10,2 180 1 11 155 136 77 M 6
DRUE 1 000 1 000 94,0 3 UI 102/ 46 13-000-09 E 3,2 1 1,3 21 0 108 175 150 80 M 8
DRUE 1 1 00 1 100 94,0 3 UI 114/ 40 13-000-10 E 4,2 1 3, 1 228 11 0 195 176 71 M 6
DRUE 1 200 1 200 94,5 3 UI 102/ 57 13-000-11 E 3,6 13,4 21 0 11 9 175 150 91 M 8
DRUE 1 500 1 500 95,0 3UI 120/ 51 13-000-12 E 4,6 1 7,0 240 12 1 205 185 81 M 8
DRUE 1 750 1 750 95,5 3UI 114/ 64 13-000-13 E 5,2 18,9 228 134 1 95 176 95 M 6
DRUE 2 000 2 000 95,5 3UI 120/ 61 13-000-14 E 6,3 2 1,0 240 13 1 205 185 91 M 8
DRUE 2 200 2 200 96,0 3UI 120/ 66 13-000-15 E 6,8 22,6 240 136 205 185 96 M 8
DRUE 2 400 2 400 96,0 3UI 120/ 71 13-000-16 E 8,0 25,0 240 14 1 205 185 101 M 8
DRUE 2 700 2 700 96,5 3UI 120/ 75 13-000-17 E 8,9 26,8 240 145 205 185 105 M 8
DRUE 3 000 3 000 96,5 3UI 132/ 72 13-000-18 E 8,4 29,2 265 152 230 200 102 M 8
DRUE 3 400 3 400 96,0 3UI 150/ 52 13-000-19 E 11,3 3 1,2 300 140 260 224 94 M 8
DRUE 4 400 4 400 96,5 3UI 150/ 65 13-000-20 E 12,2 36,6 300 153 260 224 108 M 8
DRUE 5 000 5 000 96,6 3UI 150/ 77 13-000-21 E 12,6 41,1 300 165 260 224 120 M 8
DRUE 6 000 6 000 96,8 3UI 150/ 92 13-000-22 E 15,6 49,6 300 180 260 224 134 M 8
DRUE 6 300 6 300 96,8 3UI 168/ 75 13-000-23 E 16,4 5 1,3 336 150 290 248 127 M 8
DRUE 8 000 8 000 97,1 3UI 168/ 92 13-000-24 E 20,2 62,5 336 170 290 248 144 M 8
DRUE 8 200 8 200 97,0 3UI 180/ 78 13-000-25 E 20,5 62,0 360 180 31 0 264 140 M 8
DRUE 10 000 10 000 97,4 3UI 180/ 93 13-000-26 E 26,6 76,0 360 195 31 0 264 155 M 8
DRUE 13 000 13 000 97, 1 3UI 210/ 73 13-000-27 E 37,7 90,0 420 180 360 31 6 143 M 10
DRUE 16 000 16 000 97,6 3UI 210/ 88 13-000-28 E 46,8 1 10,0 420 195 360 31 6 158 M 10
DRUE 18 000 18 000 97,8 3UI 210/103 13-000-29 E 48,6 122,0 420 21 0 360 31 6 173 M 10
DRUE 20 000 20 000 97,8 3UI 210/133 13-000-30 E 49,8 144,0 420 240 360 31 6 203 M 10
DRUE 25 000 25 000 98,2 3UI 210/133 13-000-31 E 54,8 146,0 420 240 360 31 6 203 M 10
DRUE 30 000 30 000 98,0 3UI 240/110 13-000-32 E 79,4 181,0 480 240 41 5 356 184 M 14
DRUE 36 000 36 000 98,1 3UI 240/140 13-000-33 E 88,9 218,0 480 270 41 5 356 214 M 14

Design insulation class F

Copper Total
Model Power ⬇ Core Article no. Approx. dimensions in mm
weight weight

VA % kg kg a b c d e Attach.
DRUF 6 000 6 000 95,2 3UI 150/ 77 13-000-01 F 1 2,6 4 1 ,1 300 165 260 224 120 M 8
DRUF 7 500 7 500 95,4 3UI 150/ 92 13-000-02 F 1 5,6 49,6 300 180 260 224 134 M 8
DRUF 8 000 8 000 95,6 3UI 168/ 75 13-000-03 F 1 6,4 5 1,3 336 150 290 248 127 M 8
DRUF 9 600 9 600 95,8 3UI 168/ 92 13-000-04 F 20,2 62,5 336 170 290 248 144 M 8
DRUF 10 000 10 000 95,9 3UI 180/ 78 13-000-05 F 20,5 62,0 360 180 3 10 264 140 M 8
DRUF 12 000 12 000 96,3 3UI 180/ 93 13-000-06 F 26,6 76,0 360 195 3 10 264 155 M 8
DRUF 16 000 16 000 96,8 3UI 210/ 73 13-000-07 F 33,9 86,0 420 180 360 31 6 143 M 10
DRUF 19 000 19 000 96,8 3UI 21 0/ 88 13-000-08 F 46,8 11 0,0 420 1 95 360 31 6 158 M 10
DRUF 21 500 2 1 500 97,0 3UI 2 10/103 13-000-09 F 48,6 122,0 420 2 10 360 3 16 173 M 10
DRUF 25 000 25 000 97,5 3UI 2 10/133 13-000-10 F 55,6 150,0 420 240 360 3 16 203 M 10
DRUF 30 000 30 000 98,0 3UI 2 10/133 13-000-11 F 54,8 146,0 420 240 360 3 16 203 M 10
DRUF 36 000 36 000 97,8 3UI 240/1 10 13-000-12 F 79,4 1 8 1,0 480 240 41 5 356 184 M 14
DRUF 40 000 40 000 97,9 3UI 240/140 13-000-13 F 88,9 218,0 480 270 41 5 356 2 14 M 14

Short-term delivery Subject to technical modifications

B 1/3
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 4

Three-phase dry-type transformers comp. to VDE 0532

RDST 40 – 320
In general:
The rectangular core stacks of our three-phase high power transformers are made of two-layered grain-oriented low-
loss strips. The windings consist of high-grade insulated double-lacquered massive copper. Core and windings are va-
cuum impregnated together and subsequently baked in the drying oven for several hours.
The electrical layout of the transformers is such, that high efficiency is achieved and that transformers remain well be-
low the permissible heating limit specified in VDE regulation. Sound planning guarantees an almost unlimited service life,
even when overload of transformers occurs.
RDST-transformers can be applied worldwide, meet national and international regulations and are ready for those up-
coming. Following design is available:
Three-phase dry-type transformers comp. to VDE 0532
Design:
Open frame, vertical design, stationary, for installation and set-up in dry rooms, separate windings, sturdy mounting
brackets. Connection to sturdy connection terminals (up to 450A) resp. line bars or cable terminals (measurements
are not stated below). Maximal voltage (phase-phase) 2000V.

IP 00, suitable for installation up to protection rating IP 23 naturally air self-cooling, ambient temperature 40°C.
Insulation class F (average value temperature 140°C)
Attention: Higher thermal stress at lower efficiency
Because each high power transformer is individually designed, below stated dimensions and weights may show the
currently valid state only and remains subject to modification

We manufacture three-phase dry-type transformers in all requested protection classes up to IP 65.

All types are also available as three-phase auto transformers (please find calculation method in catalogue section 'In gene-
ral', paragraph 'Transformers in economy winding').

Model with terminal blocks - above 60A

* Depending on design and winding type of special currents all measurements may vary, especi-
ally measurement b may enlarge up to 100mm!
Measurement d and e on request

Copper Total Approx. dimensions in mm


Power
Model Article no weight weight
kVA
app. kg app. kg a b* c c1 up to 63A
RDST 40 40,0 0335-00-00040 on request 1 80 550 220 460 c +100
RDST 50 50,0 0335-00-00050 on request 210 550 270 460 c +100
RDST 63 63,0 0335-00-00063 on request 250 550 300 470 c +100
RDST 80 80,0 0335-00-00080 on request 250 650 300 570 c +100
RDST 100 100,0 0335-00-00 1 00 on request 300 650 320 570 c +100
RDST 125 125,0 0335-00-00 1 25 on request 380 720 320 570 c +150
RDST 160 160,0 0335-00-00 1 60 on request 510 720 380 620 c +150
RDST 170 170,0 0335-00-00 1 70 on request 560 800 360 680 c +150
RDST 200 200,0 0335-00-00200 on request 630 800 400 680 c +150
RDST 250 250,0 0335-00-00250 on request 680 800 450 760 c +150
RDST 320 320,0 0335-00-00320 on request 840 1060 420 900 c +150

Subject to technical modifications Higher powers on request Short-term delivery


B 1/4
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 5

Three-phase starter-transformers comp. to VDE 0532

RATE 15 – 900 (insulation class E)


RATF 55 – 900 (insulation class F)
Three-phase dry-type transformers for motor starting, pump starting, compressor starting etc. featuring aggravated
starting load, rated current fusing possible, supersedes star delta-switch, comp. DIN VDE 0532 part 21

Wiring diagram for starter-transformers

Main circuit Push button for auxiliary circuit (Korndörfer-circuit)

Voltage 3AC 400V (50/60Hz), max. 15 starts/hour, max. 24 starts/day, starting time max.15 seconds, 3 steps for vol-
tage reduction to 50%, 65% and 80%, motor rush 8 x Irated, transformer-star point (2U/2V/2W) with abated cross-
section open on terminal (Korndörfer circuit), open design IP00, prepared for installation up to IP23 at natural con-
vection, version RATE features lower losses and end temperatures than RATF

Model with terminal blocks - above 60A

* Depending on design and winding type of special currents all measurements may vary, especi-
ally measurement b may enlarge up to 100mm!
Measurement d and e on request

Short-term delivery Subject to technical modifications

B 1/5
B_TEIL_041014.qxd 14.10.2004 16:18 Seite 6

Three-phase starter-transformers comp. to VDE 0532

RATE 15 – 900 (insulation class E)


RATF 55 – 900 (insulation class F)
Three phase-dry type-transformers for starting motors, pumps, compressors etc. featuring aggravated starting load,
rated current fusing possible, supersedes star delta-switch, comp. DIN VDE 0532 part 21

Design insulation class E


Copper Total
Model Motor Article no. Approx. dimensions in mm
weight weight

kW kg kg a b c d e Attach.
RATE 15 15 0321-000-015 5 19 240 130 265 185 81 M8
RATE 19 19 0321-000-019 6 23 240 140 265 185 91 M8
RATE 22 22 0321-000-022 9 27 240 150 265 185 101 M8
RATE 30 30 0321-000-030 12 33 300 155 360 224 94 M8
RATE 45 45 0321-000-045 14 44 300 165 360 224 108 M8
RATE 55 55 0321-000-055 17 55 336 180 390 248 127 M8
RATE 75 75 0321-000-075 23 66 336 200 390 248 144 M8
RATE 90 90 0321-000-090 28 80 360 230 410 264 155 M8
RATE 1 1 0 1 10 0321-000-110 39 94 420 220 460 316 143 M 10
RATE 132 1 32 0321-000-132 48 114 420 270 460 316 173 M 10
RATE 160 1 60 0321-000-160 50 127 420 290 460 316 203 M 10
RATE 220 220 0321-000-220 58 151 420 320 460 316 203 M 10
RATE 280 280 0321-000-280 80 186 480 300 530 356 184 M 14
RATE 320 320 0321-000-320 91 224 480 330 530 356 214 M 14
RATE 350 350 0321-000-350 91 224 480 340 530 356 214 M 14
RATE 375 375 0321-000-375 95 228 480 360 530 356 214 M 14
RATE 400 400 0321-000-400 86 250 550 400 600 450 ~190 M 12
RATE 630 630 0321-000-630 103 260 550 450 600 450 ~190 M 12
RATE 720 720 0321-000-720 118 300 650 400 700 560 ~190 M 12
RATE 830 830 0321-000-830 138 380 650 460 700 560 ~210 M 12
RATE 900 900 0321-000-900 145 420 720 450 730 590 ~210 M 12

Design insulation class F


Copper Total
Model Motor Article no. Approx. dimensions in mm
weight weight

kW kg kg a b c d e Attach.
RATF 55 55 0322-000-055 14 44 300 165 360 224 108 M8
RATF 75 75 0322-000-075 17 55 336 180 390 248 127 M8
RATF 90 90 0322-000-090 23 66 360 210 410 264 140 M8
RATF 1 1 0 1 10 0322-000-110 28 80 360 230 410 264 155 M8
RATF 132 1 32 0322-000-132 39 94 420 270 460 316 143 M 10
RATF 160 1 60 0322-000-160 48 114 420 290 460 316 173 M 10
RATF 220 220 0322-000-220 50 127 420 320 460 316 203 M 10
RATF 280 280 0322-000-280 58 151 420 340 460 316 203 M 10
RATF 320 320 0322-000-320 80 186 480 300 530 356 184 M 14
RATF 350 350 0322-000-350 91 224 480 330 530 356 214 M 14
RATF 375 375 0322-000-375 91 224 480 340 530 356 214 M 14
RATF 400 400 0322-000-400 95 228 480 360 530 356 214 M 14
RATF 630 630 0322-000-630 86 250 550 400 600 450 ~190 M 12
RATF 720 720 0322-000-720 103 260 550 450 600 450 ~190 M 12
RATF 830 830 0322-000-830 118 300 650 450 700 560 ~190 M 12
RATF 900 900 0322-000-900 138 380 650 470 700 560 ~210 M 12

On request other voltages, designs, sizes or also complete circuit arrangements incl. switch cabinet according to your
specifications.

Subject to technical modifications Short-term delivery


B 1/6
C
Copyright: Riedel Product group

The technical development in mobile radio has progressed far.


Certainly the user may expect to communicate anytime even
during power failure.
The economic manufacture of reliable products in state of the art
technology is a chief component of our company philosophy – a
good reason for the media industry and their suppliers to apply
Riedel products.
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 2

Examples of available
special application units

Apart from our standard delivery program we develop and manufacture custom makes. Please inquire with us.

Adjustable power supplies series RADC


800W plug-in switch power packs for Telecom and industrial application

- compact size, 800 W in 3U / 17TE


- output voltages 0-120 VDC (depending on design)
- voltage and current adjustable from 0 to max value
- modules plug-in and hot-swappable
- module alarm for remote monitoring
- meets PFC and Telecom standards
- installation both vertical 3U and horizontal 2U

19" sub-rack units series RMSR


robust power module for military and heavy-duty application

- switch power pack or battery charging systems


- parallel n+1 connection up to 90 A
- series connection up to 360 VDC
- hot-swap plug-in modules
- module failure and mains alarm
- operation temperature -40°C ... +55°C
- 19" 2U sub-rack 2400W/3 modules or 19" 3U sub-rack/4 modules

Adjustable power supplies series RADC


800W high current power supply for Telecom and industrial application

- compact size, portable laboratory unit


- output voltages 0-120 VDC (depending on design)
- voltage and current adjustable via multi-turn potentiometer from 0 to max value
- digital voltage- and current measuring units
- microprocessor controlled
- meets PFC and Telecom standards
- output current limitation against short circuit and wrong polarity
- parallel switching for increased power

Intelligent automatic charger series RALG


universal automatic-charger for 12V, 24V and 42V accumulators

- microprocessor control to identify voltage level and connected battery


- optimized charging process and charging current
- avoidance of overcharge via float charge modus
- protection against wrong polarity
- automatic switch-on and switch-off, therefore minimized sparking, battery pole damage and fire
hazard
- full protection mechanisms such as overtemperature switch-off, undervoltage switch-off,
reference control and set value / true value comparison

UPS-modules to supply industrial PCs (IPS) series RIPCUSV


supplement to series RDCUSV

- in case of line failure stabilized output voltage (20,6 VDC)


- adjustable boot time bridging (2-3-4-5 min)
- adjustable UPS-time (0,5 to 30 s), after that signal to IPC via interface
- UPS switch-off via signal of computer, automatic switch-off after adjustable waiting period
(4-6-8-10 min)
- short circuit proof
- automatic switch-off at undervoltage accumulator
- automatic charging, IU characteristic

Technical data on our homepage


www.riedel-trafobau.de

C 1/2
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 1

D.C. power supplies

We specialize in the manufacture of D.C. power supplies and offer in addition to special designs the following selec-
tion as standard delivery program:

Single-phase, see ‘Product group C’ Three-phase, see ‘Product group D’


Single-phase (rectifier) transformers, Three-phase compact rectifier transformers,
series RGT, to equip with rectifier, series RDRK and RDRKL, output 24 V DC
output 29.5 V AC for 24 V DC Three-phase universal, compact rectifier transformers
Single-phase compact rectifier transformers, series RDRKU, output 24 V DC
series GGT, output 24 V DC Three-phase compact rectifier transformers,
Single-phase compact power packs, non-stabilized, series RDRKN, output 24 V DC
series RTSNL, output 24 V DC Three-phase compact rectifier transformers,
Single-phase compact power packs, non-stabilized, series RDRKS, output 24 V DC
series RNTU, output 12 V DC or 24 V DC Three-phase compact rectifier transformers,
Single-phase compact power packs, non-stabilized, series RDRKG, output 24 V DC
UL/CSA-approbation Three-phase switch power packs, stabilized, secondary
series RNTU...UL, output 24 V DC switched
Single-phase compact power packs, stabilized, series RSNTG, output 24 V DC
series RNTG, output 24 V DC Three-phase switch power packs, stabilized, primary
Single-phase compact power packs, stabilized, UL/CSA- switched
approbation series RPL, output 24 VDC
series RNTG...UL, output 24 V DC
Single-phase switch power packs, stabilized, secondary IU battery chargers
switched series RPL, for output 12 V or 24 V Pb-battery
series RSNT, output 24 V DC IU battery chargers
Single-phase switch power packs, stabilized, primary series RLSN, for output 12 V or 24 V Pb-battery
switched
series RPL, output 12 VDC, 24 VDC or 48 VDC Non-interruptible power supplies
series RSNT GU, output 20 A DC to 60 A DC
IU battery chargers
series RLG, for 12 V or 24 V Pb-battery
IU battery chargers
series RPL, for 12 V or 24 V Pb-battery
Pulse battery chargers
series RLEC, for 12 V or 24 V NiCd-battery
Intelligent automatic charger
series RALG, for 12 V, 24 V and 42 V lead acid batteries
Other voltages and designs available on request

Non-interruptible power supplies


series RDCUSV
activation threshold 22 V DC, output 3 A DC to 40 A DC
Non-interruptible power supplies
series RDCUSV
activation threshold 20.6 V DC, output 3 A DC to 50 A DC
Accu-Packs
series RAP
DC-UPS module
model RIPCUSV 5S for industrial PCs

Power supplies with back-up battery


Series RADA, output 12/24/48 VDC

Voltage monitoring modules


Series RCV, operation voltage 24VDC

Both single- and three-phase rectifier transformers are tapped ± 5% primary for adaptation to the respective mains
supply.
The transformer´s secondary side is designed to suit a follow-up bridge rectifier. Suitable are silicon rectifiers or thyris-
tors.
Compact rectifier transformers are equipped with silicon compact bridge rectifiers and must be protected accordingly.
The D.C. voltage delivered by single-phase bridge rectifiers has a residual ripple of 48%. A lower ripple can be achieved
with a filtered protection circuit, by using three-phase transformers with subsequent three-phase bridge rectifiers (resi-
dual ripple <5%) and by using compact power packs. Stabilized power supplies achieve the lowest residual ripple.
When using rectifier transformers always take care of proper heat dissipation.
On request we supply single- and three-phase power packs as rack units, and special rectifier transformers up to
15000 A.

C 1/1
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 2

Single-phase (rectifier) transformers


Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6

RGT 100 – 630

Design: Open frame, stationary, for installation and set-up in dry rooms, sepa-
rate windings, sturdy mounting brackets. Connection to non-tracking trans-
former terminals with screw connections. The terminals are protected
against finger touch or contact with the back of the hand in compliance to ac-
cident prevention regulations (VBG 4). All types are designed for use with
bridge rectifiers under resistive load.

IP 00, suitable for installation up to protection rating IP 23, insulation class E,


max. ambient temperature ta 40°C.
Power supplies

380/400/420 V 220/230/240 V
Watt at Current
Model Power 29 V AC 29 V AC Approx. dimensions in mm
24 V DC for
Article-no. Article-no.
VA W ADC a b c d e f Attachment
RGT 100 100 72 3 15–400–29–0 1 15–230–29–0 1 85 76 95 64 61 53 M4
RGT 130 130 96 4 15–400–29–02 15–230–29–02 96 77 104 84 61 50 M5
RGT 200 200 144 6 15–400–29–03 15–230–29–03 96 87 104 84 71 54 M5
RGT 320 320 216 9 15–400–29–05 15–230–29–05 120 88 120 90 70 53 M5
RGT 400 400 288 12 15–400–29–06 15–230–29–06 120 103 120 90 82 58 M5
RGT 500 500 360 15 15–400–29–07 15–230–29–07 120 121 120 90 102 69 M5
RGT 630 630 432 18 15–400–29–08 15–230–29–08 135 116 133 104 97 63 M5

Single-phase compact
rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
GGT 100 – 630 new types with higher current

with connected rectifier, varistor and discharge resistor


Residual ripple 48%, retrofit of capacitor is not possible.
Design as above.
Harmonic rule EN 61000-3-2 is observed.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C.

380/400/420 V 220/230/240 V
Watt at
Model Output 24 V DC Current 24 V DC 24 V DC Approx. dimensions in mm
Article-no. Article-no.
VA W ADC a b c d e Attachment
GGT 100 100 72 3 16–400–024–0 1 16–230–024–0 1 84 76 100 64 61 M4
GGT 130 130 96 4 16–400–024–02 16–230–024–02 100 77 104 84 61 M5
GGT 200 200 144 6 16–400–024–03 16–230–024–03 100 87 150 84 71 M5
GGT 320 320 216 9 16–400–024–05 16–230–024–05 120 93 150 90 70 M5
GGT 400 400 288 12 16–400–024–06 16–230–024–06 120 108 160 90 82 M5
GGT 500 500 360 15 16–400–024–07 16–230–024–07 120 125 160 90 102 M5
GGT 630 630 432 18 16–400–024–08 16–230–024–08 135 138 175 104 97 M5
Subject to technical modifications Standard stock items
C 1/2
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 3

Single-phase compact power packs


Single-phase safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)

RTSNL 75 - 800 non-stabilized

Residual ripple: <5%

Design: Open vertical design, stationary, for installation and set-up in dry rooms, stur-
dy mounting brackets, quick-snap-on for 35 mm DIN rail on request, connec-
tions to non-tracking transformer terminals. The terminals are protected
against finger touch or contact with the back of the hand in compliance to
accident prevention regulations (VBG 4).
On request these units can be provided with extended mounting brackets (as
illustrated below). Further to standard types, RTSNL can also be supplied in
various primary voltages up to max. AC 690 V and secondary voltages from
DC 10 V to DC 50 V at a surcharge. Other voltages and designs available on
request.
Harmonic rule EN 61000-3-2 is observed.
IP 00 suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C.

Power supplies
Standard model:
Substructure/ sturdy mounting brackets, on request metal fastener for 35 mm DIN rail.
quick-snap-on:
Printed circuit board: epoxy resin FR 4/70 µm Cu, with solder resist and protective lacquer, 1.5 mm,
circuit traces fully solder-coated.
Terminals: polyamide 6.6, screw terminals with wire protection. The terminals are finger
and back of hand safe comp. to accident prevention regulations (VBG4)
Two-way rectification: special rectifier with particularly low flow voltage, resulting in high efficiency.
LED: green LED, 5 mm.
Fuses: primary and secondary fuses 5 x 20mm, design comp. to DIN.
Transformer: safety transformer comp. to VDE 0570, protection rating IP 00.
Varistor: S 10 K 30, protective varistor against induction peaks.
Residual ripple: at rated current and 24 V DC < 5%.
Temperature range: -20°C to +65°C
Input voltage: 220/230/240 V, 50/60 Hz
Output voltage: 24 VDC

220 / 230 / 240 V


Model Current DC 24 V Total Approx. dimensions in mm
weight
Standard Pri. Sec.
A DC Article no. fuse fuse kg a b c d d1 e Attachment
RTSNL 75 2,0 18–024–0 1 0,63 At 2,00 Amt 1,70 110 85 115 64 100 48 M4
RTSNL 100 3,0 18–024–02 0,63 At 2,50 Amt 2,1 5 110 95 115 64 100 61 M4
RTSNL 200 5,0 18–024–03 2,50 At 4,00 Amt 4,65 170 145 155 90 160 70 M5
RTSNL 400 10,0 18–024–04 3,1 5 At 10,00 Amt 5,85 170 145 170 90 160 82 M5
RTSNL 600 15,0 18–024–05 5,00 At - 8,20 190 175 190 104 180 91 M5
RTSNL 800 20,0 18–024–06 10,00 At - 9,65 190 190 190 104 180 107 M5

Standard stock items Subject to technical modifications

C 1/3
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 4

Single-phase compact power packs


Single-phase safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
RNTU 24S - 240S non-regulated

The enclosed construction of the compact and space-saving power packs series RNTU provides comprehensive protection against
accidental contact. The power packs meet the safety requirements for protection against electric shock comp. to VDE 0106 part 101.
The modules can be snapped onto the DIN EN 50 022 mounting rail quickly and easily. From DC 5 A upwards there is additional provi-
sion for screw-fastening. Identical units can be connected in parallel up to max. 90% load per unit.
The integrated fuses (see table) exclusively deliver short circuit protection and guarantee safe operation even under worst-case con-
ditions. Units are to be loaded only with rated current as indicated.
Series RNTU clearly surpasses the requirements for power packs stated in DIN EN 61131-2 / part 2 and guarantees safe operation wi-
thout alterations even after the low voltage networks will have converted pursuant to DIN IEC 38 from the year 2003 onwards. Brief
dips in line voltage are bridged by large-scale capacitors.
Apart from the specifications listed below, series RNTU can also be supplied in various primary voltages up to max. AC 400 V and se-
condary voltages ranging from DC 10 V to DC 60 V at a surcharge. However, indicated currents must not be exceeded.
Power supplies

Technical data for model RNTU 24 S RNTU 48 S RNTU 72 S RNTU 120 S RNTU 180 S RNTU 240 S
Input
Mains input voltage AC 230 V or AC 400 V
Mains input voltage range + 10 % to – 10 % comp. to DIN IEC 38
Frequency 50 Hz/60 Hz
Input fuses 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 6,3 x 32 mm 6,3 x 32 mm
AC 230 V 0,4 time lag 0,8 time lag 1,25 time lag 2,0 time lag 2,5 time lag 4,0 time lag
AC 400 V external external external external 1,6 time lag 2,5 time lag
Output
Output voltage EN 61131-2/part 2 DC 24 V or DC 12 V, twin terminals
Status display green LED
Output fuse 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 6,3 x 32 mm 6,3 x 32 mm
1,25 time lag 2,5 time lag 4,0 time lag 6,3 time lag 10 time lag 12 time lag
Power 24 W 48 W 72 W 120 W 180 W 240 W
Permissible permanent output current DC 1 A DC 2 A DC 3 A DC 5 A DC 7,5 A DC 10 A
Residual ripple < 5%
Ambient temperature range – 10 ° C/+ 60° C
Output protection circuitry varistor
General data
Test voltage between input and output circuit comp. to regulations (safety transformers)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE-mark yes
Installation orientation any position
Type of connection screw-type terminal, finger-safe comp. to VBG4
2
Connection data fine strand max. 2,5 mm
Mounting mounting rail (DIN EN 50 022), beginning with RNTU 120S additional
screw-connection possible, in rows spaced > 8 mm
TS 35 x 7,5 TS 35 x 15
Protection rating comp. VDE 0470 / EN 60529 IP 20
Safety class comp. IEC 536 / VDE 0106 T1 prepared for protection class II
Insulation class E
Dimensions in mm approx. Length L 77 77 82 134 157 157
Width W 62,5 62,5 90 125 175 175
Mounting depth D 122 122 128 153 185 185
Article no. AC 230 V/DC 1 2 V 223-024S 223-048S 223-072S 223-120S 223-180S 223-240S
Article no. AC 230 V/DC 24 V 224-024S 224-048S 224-072S 224-120S 224-180S 224-240S
Article no. AC 400 V/DC 24 V 226-024S 226-048S 226-072S 226-120S 226-180S 226-240S
Total weight in kg 0,95 1 ,20 2,35 3,9 5,2 6,3
Subject to technical modifications Standard stock items
C 1/4
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 5

Single-phase compact power packs


RNTU 24S UL – 240S UL, certificate UL 508 / CSA 22.2-C, non-regulated
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)

Series RNTU-UL provides efficient power packs featuring high reliability and compact measurements. Series RNTU-UL distinctly sur-
passes power pack requirements DIN EN 61131-2 / part 2 and guarantees safe operation without alterations even after the low volta-
ge networks have converted pursuant to DIN IEC 38 from the year 2003 onwards. Brief dips in line voltage are bridged up to 10 ms by
large-scale electrolytic capacitors.
Apart from the specifications listed below, series RNTU-UL can also be supplied in secondary voltages ranging from DC 10 V to DC 60
V and on request also with various primary voltages. However, indicated currents must not be exceeded.
Identical units can be connected in parallel up to max. 90% load per unit.
The integrated fuses (see table) exclusively deliver short circuit protection and guarantee safe operation even under worst-case con-
ditions. Units are to be loaded only with rated current as indicated.
The enclosed construction of the space-saving power packs series RNTU-UL provides comprehensive protection against accidental
contact. The power packs meet the safety requirements for protection against electric shock comp. to VDE 0106 part 101. The modu-
les can be snapped onto DIN EN 50 022 mounting rails quickly and easily. From DC 5 A upwards there is additional provision for screw-
fastening.

Power supplies
RNTU 72S UL, 24S UL RNTU 240S UL, 120S UL

Technical data for model RNTU 24 S UL RNTU 72 S UL RNTU 120 S UL RNTU 180 S UL RNTU 240 S UL
Input
Mains input voltage AC 230 V and AC 115 V (AC 240 V and AC 120 V)
Mains input voltage range + 10 % to – 10 %
Frequency 60 Hz
Input fuses 5 x 20 mm 5 x 20 mm 5 x 20 mm 6,3 x 32 mm 6,3 x 32 mm
0,7 time lag 1,6 time lag 3,2 time lag 4,0 time lag 5,0 time lag
Output
Output voltage EN 61131-2/part 2 DC 24 V
Status display green LED
Output fuse 5 x 20 mm 5 x 20 mm 5 x 20 mm 6,3 x 32 mm 6,3 x 32 mm
1,25 A quick 4,0 A quick 6,3 A quick 10 A m. time lag 12 A m. time lag
Power 24 W 72 W 120 W 180 W 240 W
Permissible permanent output current DC 1 A DC 3 A DC 5 A DC 7,5 A DC 10 A
Residual ripple < 5%
Ambient temperature range – 10 ° C/+ 40° C
Output protection circuitry varistor
General data
Test voltage between input and output circuit comp. to regulations
Directives UL 508, CSA 22.2 No. 14, comp. to EN 61558-2-1, EN 61000-3-2, EN 61131-2/part 2
Test mark UL + CSA - File-No. E242971
CE- mark yes
Installation orientation any position
Type of connection screw-type terminal, finger-safe comp. to VBG4
2
Connection data fine strand max. 2,5 mm
Mounting mounting rail (DIN EN 50 022), beginning with RNTU 120S UL, additional
screw-connection possible, in rows spaced > 8 mm
TS 35 x 7,5 TS 35 x 15
Protection rating comp. VDE 0470 / EN 60529 IP 20
Safety class comp. IEC 536 / VDE 0106 T1 I
Insulation class E
Dimensions in mm approx. Length L 77 82 134 157 157
Width W 62,5 90 125 175 175
Mounting depth D 122 128 153 185 185
Article no. 0284-00024SUL 0284-00072SUL 0284-000120SUL 0284-000180SUL 0284-000240SUL
Copper weight in kg 0,1 2 0,36 0,6 0,97 1 , 18
Total weight in kg 0,95 2,35 3,9 5,2 6,3

Standard stock items Subject to technical modifications

C 1/5
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 6

Single-phase compact power packs


Single-phase safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
RNTG 12S - 120S regulated

The enclosed construction of the compact and space-saving power packs series RNTG provides comprehensive protection against
accidental contact. The power packs meet the safety requirements for protection against electric shock comp. to VDE 0106 part 101
and can be snapped onto DIN EN 50 022 mounting rail quickly and easily. RNTG120S / DC 5 A shows additional provision for screw-fa-
stening.
Identical units can be connected in parallel up to max. 80% load per unit.
The integrated fuses (see table) exclusively deliver short circuit protection and guarantee safe operation even under worst-case con-
ditions. Units are to be loaded only with rated current as indicated.
Series RNTG clearly surpasses the requirements for power packs stated in EN 61131-2 / part 2 and guarantees safe operation without
alterations even after the low voltage networks have converted pursuant to DIN IEC 38 from the year 2003 onwards. Brief dips in line
voltage are bridged up to 10 ms at rated duty.
Apart from the specifications listed below, series RNTG can also be supplied in various primary voltages up to max. AC 400 V and se-
condary voltages ranging from DC 5 V to DC 30 V at a surcharge. However, indicated currents must not be exceeded.
Power supplies

Technical data for model RNTG 12 S RNTG 24 S RNTG 48 S RNTG 72 S RNTG 120 S
Input
Mains input voltage AC 230 V
Mains input voltage range + 10 % to – 10 % comp. to DIN IEC 38
Frequency 50 Hz/60 Hz
Input fuses 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm
0,2 A time lag 0,4 A time lag 0,8 A time lag 1,25 A time lag 2,0 A time lag
Output
Output voltage EN 61131-2/part 2 24 V DC, twin terminals, adjustable +/- 2 V
Status display green LED
Output fuse 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm
0,7 A quick 1,25 A quick 2,5 A quick 3,15 A quick 5,0 A quick
Power 12 W 24 W 48 W 72 W 120 W
Permissible permanent current 0,5 A 1,0 A 2,0 A 3,0 A 5,0 A
Residual ripple < 2 m V RMS
Load stabilization < 0,1 %
Stability under constant conditions < 0,1 %
Ambient temperature – 10 ° C/+ 40° C
Output power reduction at 40°C and above > 1.5% / degree
Output protection circuitry varistor
General data
Test voltage between input and output circuit comp. to regulations (safety transformers)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE-mark yes
Installation orientation any position
Type of connection screw-type terminal, finger-safe comp. to VBG4
2
Connection data fine strand max. 2,5 mm
Mounting mounting rail (DIN EN 50022), RNTG 120S has additional screw-connection,
in rows spaced > 8 mm
Protection rating comp. VDE 0470 / EN 60529 IP 20
Safety class comp. IEC 536 / VDE 0106 T1 prepared for protection class II
Insulation class E
Dimensions in mm approx. Length L 77 77 82 82 134
Width W 62,5 62,5 90 90 125
Mounting depth D 122 122 138 153 178
Article no. 225-012S 225-024S 225-048S 225-072S 225-120S
Copper weight in kg 0,12 0,36 0,6 0,97 1,18
Total weight in kg 0,9 0,95 1,9 2,6 4,3

Subject to technical modifications Standard stock items


C 1/6
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 7

Single-phase compact power packs


RNTG 12S UL – 120S UL, certificate UL 508 / CSA 22.2-C, regulated
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)

Series RNTG-UL provides stabilized power packs showing high reliability and compact measurements. Series RNTG-UL distinctly sur-
passes power pack requirements EN 61131-2 / part 2 and guarantees safe operation without alterations even after the low voltage
networks have converted pursuant to DIN IEC 38 from the year 2003 onwards. Brief dips in line voltage are bridged up to 10 ms.
Apart from the specifications listed below, series RNTG-UL can also be supplied in secondary voltages ranging from DC 5 V to DC 30 V
and on request also with various primary voltages. However, indicated currents must not be exceeded.
Identical units can be connected in parallel up to max. 80% load per unit.
The integrated fuses (see table) exclusively deliver short circuit protection and guarantee safe operation even under worst-case con-
ditions. Units are to be loaded only with rated current as indicated.
The enclosed construction of the space-saving power packs series RNTG-UL provides comprehensive protection against accidental
contact. The power packs meet the safety requirements for protection against electric shock comp. to VDE 0106 part 101. The modu-
les can be snapped onto DIN EN 50 022 mounting rails quickly and easily. RNTG120S UL / DC 5 A shows additional provision for
screw-fastening.

Power supplies
Technical data for model RNTG 12 S UL RNTG 24 S UL RNTG 48 S UL RNTG 72 S UL RNTG 120 S UL
Input
Mains input voltage AC 230 V and AC 115 V (AC 240 V and AC 120 V)
Mains input voltage range + 10 % to – 10 %
Frequency 60 Hz
Input fuses 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm
0,4 A time lag 0,8 A time lag 1,25 A time lag 2,0 A time lag 3,5 A time lag
Output
Output voltage EN 61131-2/part 2 24 V DC, adjustable +/– 2 V
Status display green LED
Output fuse 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm
0,7 A quick 1,25 A quick 2,5 A quick 3,15 A quick 5,0 A quick
Power 12 W 24 W 48 W 72 W 120 W
Permissible permanent current 0,5 A 1,0 A 2,0 A 3,0 A 5,0 A
Residual ripple < 2 m V RMS
Load stabilization < 0,1 %
Stability under constant conditions < 0,1 %
Ambient temperature – 10 ° C/+ 40° C
Output power reduction ab 40° C > 1,5 % / Grad
Output protection circuitry varistor, inverse diode
General data
Test voltage between input and output circuit comp. to regulations
Directives UL 508, CSA 22.2 No. 14, comp. EN 61558-2-1, EN 61000-3-2, EN 61131-2/part 2
Test mark UL + CSA - File-No. E242971
CE-mark yes
Installation orientation any position
Type of connection screw-type terminal, finger-safe comp. to VBG4
2
Connection data fine strand max. 2,5 mm
Mounting mounting rail (DIN EN 50022), RNTG 120S UL shows additional
screw-connection, in rows spaced >8mm
Protection rating comp. VDE 0470 / EN 60529 IP 20
Safety class comp. IEC 536 / VDE 0106 T1 prepared for safety class II
Insulation class E
Dimensions in mm approx. Length L 77 77 82 82 134
Width W 62,5 62,5 90 90 125
Mounting depth D 122 122 138 153 178
Article no. 0285-00012SUL 0285-00024SUL 0285-00048SUL 0285-00072SUL 0285-000120SUL
Copper weight in kg 0,12 0,36 0,6 0,97 1,18
Total weight in kg 0,9 1,2 1,9 2,6 4,3

Standard stock items Subject to technical modifications

C 1/7
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 8

Single-phase switch power packs


Single-phase safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
RSNT 5 – 15S regulated
Our secondary switched power packs feature high stability and long service life. The patented switching concept ensures an extre-
mely low interference level and therefore does not require any filtering or shielding whatsoever. The interference level distinctly re-
mains below the permissible limits EN 55011 class B.. Consequently series RSNT excellently suits laboratory use also.
An internal electronic fuse ensures that the units always operate within safe operating range (SOA protection).
RSNT...S design: fully enclosed construction provides comprehensive protection against accidental contact; various primary voltages
up to max. AC 400 V available at a surcharge.
RSNT version: Partially enclosed construction with sturdy mounting brackets; various primary voltages up to max. AC 690 V available
at a surcharge.
Power supplies

Technical data for model RSNT 10S RSNT 15S RSNT 5 RSNT 10 RSNT 15
Input
Mains input voltage AC 230 V or AC 400V AC 230V and AC 400V
Mains input voltage range + 15 % to – 15 %
Frequency 50 Hz/60 Hz
Input fuses 5 x 20 mm 6,3 x 32 mm external external external
AC 230V 4,0 A time lag 6,3 A time lag 4,0 Agl 4,0 Agl 6,0 Agl
AC 400V external external 2,0 Agl 2,0 Agl 4,0 Agl
Output
Output voltage DC 24 V stabilzed, twin terminals, DC 24 V stabilzed, twin terminals,
adjustable 0...DC30V adjustable 5...DC28V
Status display green / yellow LED (U / I) green LED: constant voltage / red LED: error
Adjustable output current 0...10 A 0...15 A 1...5 A 2...10 A 3...15 A
Residual ripple < 30 mV RMS < 50 mV RMS
Short-circuit proofing constant current operation constant current operation / off after 3 s.
switch back on with Reset-button
Load stabilization dynamic < 100 mVss / 500us. < 300 mVss / 500us.
Stability under constant conditions < 0,05 % < 0,1 %
Mains stabilization < 0,05 %
Overtemperature protection thermal switch-off when unit > 85°C
Suppression grade EN 55011 Klasse B
Ambient temperature -10... +40°C
General data
Transformer test voltage between input and output circuit comp. to regulations (safety transformers)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE-mark yes
Installation orientation vertical any position
on EN 50022 rail
Type of connection screw-type terminal, finger-safe comp. to VBG4
2 2
Connection data fine strand max. 2,5 mm fine strand max. 4 mm
Mounting on mounting rail, mounting brackets
screw-fasten in addition
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 00
Safety class comp. IEC 536 / VDE 0106 T1 I
Insulation class E
Dimensions in mm approx. ( L x W x D ) 134 x 125 x 180 157 x 175 x 197 125 x 132 x 150 170 x 170 x 175 190 x 180 x 190
Mounting template in mm, approx. 87 x 120 130 x 154 x 154 84 x 71 90 x 84 104 x 97
Article no. AC 230V 0219-00000010S 0219-00000015S valid for both primary voltages
AC 400V 0319-00000010S 0319-00000015S 24-230-SNT-01 24-230-SNT-02 24-230-SNT-03
Copper weight in kg 0,75 1 ,2 0,6 1 ,2 1 ,4
Total weight in kg 5,0 9,2 5,5 6,5 7,5
Options
Remote control 0 - 10V for U / I for U / I - - for U
Remote control 4mA - 20mA for U / I for U / I - - -
Switch-off input yes yes - - yes
Signal contact "Ready" yes yes - - yes
Subject to technical modifications Standard stock items
C 1/8
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 9

Primary switched single-phase power packs


RPL 122.5 W – 4810 E comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated

In General: Within the scope of European norms limit values for harmonic currents are defined and must be adhered to in all
units: > 75 Watt and < 1000 Watt (EN 61 000-3-2). Units applied in systems possessing their own medium voltage
transformer are exempted from this norm.
All power supplies marked PFC are fitted with harmonic filters when applied within the scope of the norm. The filter
is active at mains input voltage range 184 V - 264 V.

Features: - wide input voltage range for 30 W and 60 W units, 125 W and up input 230 VAC and/or 115 VAC
30W units available in 85 up to 265VAC (type...W) or 195 up to 460VAC (type...W1)
- output voltage 12, 24 or 48 VDC, over a wide range adjustable
- connection in parallel or series
- high efficiency
- compact and robust design in metal housing, 30 W units in plastic enclosure
- easy installation on DIN mounting rail, alternative screw fastening
- safety class I
- interference emission EN 55011 class B (industry), EN 55022 class B (Telecom)
- interference immunity EN 50082-2: ESD, electromagnetic irradiation, burst, conducted interference immunity,
mains voltage dips
- excess current limiter, short-circuit protection, overvoltage limitation and overtemperature protection

Power supplies
- inrush current limiter
- status display: LED
- all power packs series RPL can be also delivered as battery chargers (type ...WL)
- power packs 30 W, 60 W and 480 W can be applied without alterations as D.C./D.C.-converters

Chart:

Model Model Model Model Norm EN


Power Voltage/Current wide voltage input input input Article.-no. 61000-3-2
range 230/115VAC 230VAC 115VAC met
DC 12V / 2.5A RPL 1 22.5 W 0500-00122.5W Norm does not apply
30 W
DC 24V / 1.25A RPL 241.25 W 0500-0241.25W Norm does not apply
(AC 85-265V)
DC 48V / 0.65A RPL 480.65 W 0500-0480.65W Norm does not apply
DC 12V / 2.5A RPL 1 22.5 W1 0500-0122.5W1 Norm does not apply
30 W
DC 24V / 1.25A RPL 241.25 W1 0500-241.25W1 Norm does not apply
(AC 195-460V)
DC 48V / 0.65A RPL 480.65 W1 0500-480.65W1 Norm does not apply
DC 12V / 5A RPL 1205 E 0500-0001205E Norm does not apply
60 W DC 24V / 2.5A RPL 242.5 E 0500-00242.5E Norm does not apply
DC 48V / 1.25A RPL 481.25 E 0500-0481.25E Norm does not apply
DC 12V / 10A RPL 1210 E 0500-0001210E yes
125 W DC 24V / 5A RPL 2405 E 0500-0002405E yes
DC 48V / 2.5A RPL 482.5 E 0500-00482.5E yes
DC 12V / 20A RPL 1220 E 0500-0001220E no
250W DC 24V / 10A RPL 2410 E 0500-0002410E no
DC 48V / 5A RPL 4805 E 0500-0004805E no
DC 12V / 20A RPL 1220 PFC 0500-0001220P yes
250W DC 24V / 10A RPL 2410 PFC 0500-0002410P yes
DC 48V / 5A RPL 4805 PFC 0500-0004805P yes
DC 24V / 20A RPL 2420 E 0500-0002420E no
DC 48V / 10A RPL 4810 E 0500-0004810E no
480W DC 24V / 20A RPL 2420 E1 0500-002420E1 no
DC 48V / 10A RPL 4810 E1 0500-004810E1 no
DC 24V / 20A RPL 2420 PFC 0500-0002420P yes
480W DC 48V / 10A RPL 4810 PFC 0500-0004810P yes

Options: - other input- and output voltages possible


- units of lesser power, suitable also for application in Telecom
- units with multiple output voltages
- overload and short circuit behavior can be realized to customer's requirements
Standard Stock items Subject to technical modifications

C 1/9
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 10

Primary switched single-phase power packs


RPL 122.5 W – 480.65 W1 comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
application as D.C./D.C.-converter possible
Technical data 30W 30W
Model RPL 12 2.5 W RPL 24 1.25 W RPL 48 0.65 W RPL 12 2.5 W1 RPL 24 1.25 W1 RPL 48 0.65 W1
INPUT
Rated input voltage, U1 rated AC 100V - 240V AC 220V - 400V
Voltage range, U1min - U1max AC 85V - 265V or DC 100V - 375V AC 195V - 460V or DC 230V - 650V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 460V
Rated current typical, I1 rated 0,32A at 230VAC ; 0,61A at 115VAC 0,32A at 230VAC ; 0,19A at 400VAC
Maximum transient pulse Ta = 25°C < 25A at 230VAC ; < 13A at 115VAC < 25A at 230VAC ; < 35A at 400VAC
Maximum transient pulse Ta = 55°C < 50A at 230VAC ; < 26A at 115VAC < 50A at 230VAC ; < 60A at 400VAC
Internal fuse T1.25A with high switch-off ability -
Recommended external fuse power circuit breaker C6, B10 power circuit breaker C6, B10
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 50ms at 230VAC ; > 10ms at 115VAC > 10ms at 230VAC ; > 20ms at 400VAC
Reverse polarity protection D.C.-input yes yes
OUTPUT
Rated voltage U2 rated D.C. DC 12V DC 24V DC 48V DC 12V DC 24V DC 48V
Voltage range U2 min - U2 max D.C. 10-15V 23-29V 45-58V 10-15V 23-29V 45-58V
Power supplies

Rated current I2 (at U2 rated) 2.5A 1.25A 0.65A 2.5A 1.25A 0.65A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical 2.6A 1.3A 0.7A 2.6A 1.3A 0.7A
Short circuit current typical < 5A < 3A < 2A < 5A < 3A < 2A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 10mV RMS < 10mV RMS
Mains stabilization U1 min - U1 max < 0,1 % < 0,1 %
Load stabilization load alteration < 0,5 % < 0,5 %
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.03% / K < 0.03% / K
Operation in parallel and series yes yes
Status reports LED green LED green
DIRECTIVES
Mains harmonics limit EN 61000-3-2 not necessary not necessary
Interference emission EN 50081-1, EN 55011 class B, EN 55022 class B EN 50081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test voltage input/housing - -
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing - -
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 80% > 82% > 82% > 80% > 82% > 82%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature 0°C up to +55°C -20°C up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM5,08mm to screw
2-pole 0,75-2,5mm2 (+ -) 2-pole 0,75-2,5mm2 (+ -)
Housing design plastic plastic
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation vertical vertical
Approx. dimensions (W x H x D) 40 x 80 x 85 mm 40 x 80 x 85 mm
Approx. total weight 0,14kg 0,14kg

Subject to technical modifications Standard stock items


C 1/10
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 11

Primary switched single-phase power packs


RPL 1205 E – 482.5 E comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
60W units applicable as D.C./D.C.-converters
Technical data 60W 125W
Model RPL 12 05 E RPL 24 2.5 E RPL 48 1.25 E RPL 12 10 E RPL 24 05 E RPL 48 2.5 E
INPUT
Rated input voltage, U1 rated AC 100V - 240V AC 115V and AC 230V
Voltage range, U1min - U1max AC 90 - 264V or DC 120V - 375V AC 94 - 132V or AC 184 - 264V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 275V
Rated current typical, I1 rated 0.7 A at 230VAC ; 1.2A at 115VAC 1,3A at 230VAC ; 2,2A at 115VAC
Maximum transient pulse Ta = 25°C < 25A at 230VAC ; < 12A at 115VAC < 45A at 230VAC ; < 22A at 115VAC
Maximum transient pulse Ta = 55°C < 55A at 230VAC ; < 29A at 115VAC < 85A at 230VAC ; < 43A at 115VAC
Internal fuse T2.0A with high switch-off ability T6.3A with high switch-off ability
Recommended external fuse power circuit breaker C6, B10 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 50ms at 230VAC ; > 10ms at 115VAC > 20ms
Reverse polarity protection D.C.-input yes -
OUTPUT
Rated voltage U2 rated D.C. DC 12V DC 24V DC 48V DC 12V DC 24V DC 48V
Voltage range U2 min - U2 max D.C. 10,5-15V 21-29V 45-58V 9-15V 21-29V 45-58V

Power supplies
Rated current I2 (at U2 rated) 5.0A 2.5A 1.25A 10A 5A 2.5A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical < 8A < 4A < 2A < 11A < 6A < 3A
Short circuit current typical < 12A < 9A < 6A < 16A < 10A < 6A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 15mV RMS < 10mV RMS < 15mV RMS < 10mV RMS
Mains stabilization U1 min - U1 max < 0,15 % < 0,15 %
Load stabilization load alteration < 1,0 % < 0,5 % < 1,0 % < 0,5 %
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.02% / K < 0.02% / K
Operation in parallel and series series operation yes. For parallel operation extern yes
series diode necessary
Statusmeldungen LED - green LED - green
Noise output zero potential change-over contact yes yes
Temperature compensation (battery charger) 2,2k⍀-NTC (f.example Siemens B57045K222K) 2,2k⍀-NTC (f.example Siemens B57045K222K)
external NTC-resistor
DIRECTIVES
Mains harmonics limit EN 61000-3-2 not necessary yes
Interference emission EN 50081-1, EN 55011 class B, EN 55022 class B EN 50081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class 1
Test voltage input/housing 1500VAC RMS 50Hz, 1min 1500VAC RMS 50Hz, 1min
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 82% > 83% > 84% > 85% > 88% > 89%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature -40°C up to +55°C -40°C up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM5,08mm to screw
2-pole 0,75-2,5mm2 (+ -) 2-pole 0,75-2,5mm2 (+ -)
Connection noise output connector RM5,08mm to screw connector RM5,08mm to screw
temperature compensation 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2) 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2)
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation vertical any position
Approx. dimensions (W x H x D) 51 x 121 x 81 mm 66 x 148 x 113 mm
Approx. total weight 0,36kg 0,84kg
Standard stock items Subject to technical modifications

C 1/11
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 12

Primary switched single-phase power packs


RPL 1220 PFC – 4810 PFC comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
480W units applicable as D.C./D.C.-converters
Technical data 250W 480W
Model RPL 12 20 PFC RPL 24 10 PFC RPL 48 05 PFC RPL 24 20 PFC RPL 48 10 PFC
INPUT
Rated input voltage, U1 rated AC 115V and AC 230V AC 230V
Voltage range, U1min - U1max AC 94 - 132V or AC 184 - 264V AC 196-264V or DC 270V-375V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 275V
Rated current typical, I1 rated 1,9A at 230VAC ; 4,2A at 115VAC 3,1A at 230VAC
Maximum transient pulse Ta = 25°C < 35A at 230VAC ; < 17A at 115VAC < 11A at 230VAC
Maximum transient pulse Ta = 55°C < 69A at 230VAC ; < 33A at 115VAC < 30A at 230VAC
Internal fuse T6,3A with high switch-off ability T6,3A with high switch-off ability
Recommended external fuse power circuit breaker B10, B16 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 20ms > 30ms
Reverse polarity protection D.C.-input - yes
OUTPUT
Rated voltage U2 rated D.C. DC 12V DC 24V DC 48V DC 24V DC 48V
Voltage range U2 min - U2 max D.C. 9-15V 21-29V 45-58V 23-29V 45-58V
Power supplies

Rated current I2 (at U2 rated) 20A 10A 5A 20A 10A


Protection overload, short circuit, no-load yes yes
Overcurrent limit typical < 22A < 11A < 6A 20,5A 11A
Short circuit current typical < 27A < 14A < 7A < 22A < 12A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 15mV RMS < 10mV RMS < 60mV RMS
Mains stabilization U1 min - U1 max < 0,15 % < 0,05 % < 0,05 %
Load stabilization load alteration < 1,0 % < 0,5 % < 0,25 %
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.02% / K < 0.02% / K
Operation in parallel and series yes yes
Status reports LED green LED green
Noise output zero potential change-over contact yes no
Temperature compensation (battery charger) 2,2k⍀-NTC (f. example Siemens B57045K222K) -
external NTC-resistor
DIRECTIVES
Mains harmonics limit EN 61000-3-2 yes yes
Interference emission EN 50081-1, EN 55011 class B, EN 55022 class B EN 50081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test voltage input/housing 1500VAC RMS 50Hz, 1min 1500VAC RMS 50Hz, 1min
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 85% > 89% > 90% > 92%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature -40°C up to +55°C 0°C up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM5,08mm to screw
4-pole 0,75-2,5mm2 (++ --) 4-pole 0,75-4,0mm2 (++ --)
Connection noise output connector RM5,08mm to screw -
temperature compensation 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2)
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation any position front plate horizontal, connections below
Approx. dimensions (W x H x D) 75 x 173 x 122 mm 245 x 138 x 100 mm
Approx. total weight 1,5kg 2,4kg

Subject to technical modifications Standard stock items


C 1/12
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 13

Primary switched single-phase power packs


RPL 1220 E – 4810 E1 comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated 480W * units applicable as D.C./D.C.-converters

Technical data 250W 480W


Model RPL 12 20 E RPL 24 10 E RPL 48 05 E RPL 24 20 E * RPL 48 10 E * RPL 24 20 E1 RPL 48 10 E1
INPUT
Rated input voltage, U1 rated AC 115V and AC 230V AC 230V AC 115V
Voltage range, U1min - U1max AC 94 - 132V or AC 184 - 264V AC 196-264V / DC 270V-375V AC 93-132V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 275V varistor AC 150V
Rated current typical, I1 rated 2,5A at 230VAC ; 4,2A at 115VAC 3,6A at 230VAC 5,6A at 115VAC
Maximum transient pulse Ta = 25°C < 35A at 230VAC ; < 17A at 115VAC < 11A at 230VAC < 11A at 115VAC
Maximum transient pulse Ta = 55°C < 69A at 230VAC ; < 33A at 115VAC < 30A at 230VAC < 30A at 115VAC
Internal fuse T6,3A with high switch-off ability T6,3A with high switch-off ability
Recommended external fuse power circuit breaker B10, B16 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 20ms > 40ms at 230VAC > 40ms at 115VAC
Reverse polarity protection D.C.-input - yes
OUTPUT
Rated voltage U2 rated D.C. DC 12V DC 24V DC 48V 24V 48V 24V 48V
Voltage range U2 min - U2 max D.C. 9-15V 21-29V 45-58V 23-29V 45-58V 23-29V 45-58V

Power supplies
Rated current I2 (at U2 rated) 20A 10A 5A 20.0A 10.0A 20.0A 10.0A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical < 22A < 11A < 6A 20.5A 11.0A 20.5A 11.0A
Short circuit current typical < 27A < 14A < 7A < 22A < 12A < 22A < 12A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 15mV RMS < 10mV RMS < 60mV RMS
Mains stabilization U1 min - U1 max < 0,15 % < 0,05 %
Load stabilization load alteration < 1,0 % < 0,5 % < 0,25%
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.02% / K < 0,02% / K
Operation in parallel and series yes yes
Status reports LED green LED green
Noise output zero potential change-over contact yes -
Temperature compensation (battery charger) 2,2k⍀-NTC -
external NTC-resistor (f. example Siemens B57045K222K)
DIRECTIVES
Mains harmonics limit EN 61000-3-2 no no not necessary
Interference emission EN 50081-1, EN 55011 class B, EN 50081-1, EN 55011 class B,
EN 55022 class B EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test mark / approbation - cUL - -
Test voltage input/housing 1500VAC RMS 50Hz, 1min 1500VAC RMS 50Hz, 1min
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark no no not necessary
OPERATING DETAILS
Efficiency typical > 85% > 89% > 90% > 92%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature -40°C up to +55°C 0 up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM7,62mm to screw
4-pole 0,75-2,5mm2 (+ -) 4-pole 0,75-4,0mm2 (+ + - -)
Connection noise output connector RM5,08mm to screw -
temperature compensation 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2)
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation any position front plate horizontal, connections below
Approx. dimensions (W x H x D) 75 x 173 x 122 mm 245 x 138 x 100 mm
Approx. total weight 1,3kg 2,0kg
Standard stock items Subject to technical modifications
C 1/13
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 14

C 1/14
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 15

Single-phase IU battery chargers


RLG 1203S – 2415S comp. to VDE 0570 part 2-6, EN 61558-2-6

The battery chargers series RLG..S charge maintenance-free lead acid batteries swiftly and gently using IU characteri-
stic.

An internal electronic regulation ensures that units always work within safe operating range (SOA protection), thereby
enabling permanent operation without maintenance.

A two-color LED indicates charging state.

Buffer-battery system is fully guaranteed, i.e. energy can also be drawn during mains connection. The reverse current
is <=1mA during switch off condition.

Battery chargers RLG 1205S to RLG 2415S feature IUoU charging characteristic, which charges a battery with constant
current to just below gaseous voltage. Then this output voltage is maintained (see diagram) for a factory-set period of
time. At the end of this period the constant voltage is reduced to trickle voltage. An additional LED (yellow) lights up
when unit reduces the output voltage to trickle voltage thereby indicating that charging procedure is completed.

Such a characteristic charges lead acid batteries optimally, resulting in high capacity while treating the connected bat-
tery gently and preventing sulphate build-up.

The battery chargers are installed in compact plastic enclosures ensuring full protection against accidental contact.
They meet requirements VDE 0106 part 101 for protection against electric shock.

The enclosure is designed for quick and simple mounting on DIN EN 50022 mounting rails.

battery chargers
IUoU charging characteristic
IU charging characteristic

yellow

C 1/15
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 16

Single-phase IU battery chargers


RLG 1203S – 2415S comp. VDE 0570 part 2-6, EN 61558-2-6

Technical data for model RLG 1203S RLG 1205S RLG 1208S RLG 1210S RLG 1215S
RLG 2403S RLG 2405S - RLG 2410S RLG 2415S
Input
Mains input voltage AC 230 V or AC 400V
Mains input voltage range + 10 % up to – 10 % comp. to IEC 38 +- 15%
Frequency 50 Hz/60 Hz
Input fuses 5 x 20 mm 5 x 20 mm 5 x 20 mm 5 x 20 mm 6,3 x 32 mm
AC 230V / DC 12V 0,80 A time lag 1,25 A time lag 2,0 A time lag 2,0 A time lag 4,0 A time lag
AC 230V / DC 24V 1,25 A time lag 2,50 A time lag - 4,0 A time lag 6,3 A time lag
AC 400V / DC 12V external external external external external
AC 400V / DC 24V external external - external external
Output
Rated battery voltage DC 12 V DC 12 V DC 12 V DC 12 V DC 12 V
DC 24 V DC 24 V - DC 24 V DC 24 V
Max. charge current DC 3 A DC 5 A DC 8 A DC 10 A DC 15 A
Battery type lead acid batteries
Status display twin-colour LED red: charging red: charging yellow: constant current
green: I < 10%IN green: I < 10%IN green: constant voltage
yellow LED - maintaining charge maintaining charge
Residual ripple of charge voltage < 0,5%
Charging characteristic IU IUoU; preset time 4 h
Overload protection internal electronic current limiter
Reverse current when mains off, I = < 1 mA
Reverse polarity protection integrated (reverse polarity current < 1 mA)
battery chargers

Overtemperature protection automatic cut-off if charger temperature > 85°C


RFI suppression better than EN 55011 class B
Ambient temperature range 0... +40°C
General data
Transformer test voltage between input- and output circuit comp. to regulation (safety transformer)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE-mark yes
Installation orientation vertical
Cooling convection
Type of connection P.C. terminals
2
Connection data fine strand max. 2,5 mm
Mounting on mounting rail (DIN EN 50022) on mounting rail
spacing > 8 mm screw-fasten additionally
Protection rating comp. VDE 0470 / EN 60529 IP 20
Protection class comp. IEC 536 / VDE 0106 T1 prepared for protection class II
Insulation class E
Approx. dimensions in mm length L 82 134 157
width W 90 125 175
depth D 135 175 210
Mounting template in mm, approx. - 87 x 120 130 x 154 x 154
Article no. AC 230V / DC 12 V 0235-000 1203S 0235-000 1205S 0235-000 1208S 0235-000 1210S 0235-000 1215S
AC 230V / DC 24 V 0235-0002403S 0235-0002405S - 0235-0002410S 0235-0002415S
AC 400V / DC 12 V 0245-000 1203S 0245-000 1205S 0245-000 1208S 0245-000 1210S 0245-000 1215S
AC 400V / DC 24 V 0245-0002403S 0245-0002405S - 0245-0002410S 0245-0002415S
Copper weight in kg 0,97 1, 18 1 ,18 1, 18 1,30
Total weight in kg 2,50 4,30 4,30 4,50 6,60

Subject to technical modifications Standard stock items


C 1/16
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 17

Primary switched single-phase battery chargers


RPL 122.5 WL – 4810 EL comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated

In General: Within the scope of European norms limit values for harmonic currents are defined and must be adhered to in all
units: > 75 Watt and < 1000 Watt (EN 61 000-3-2). Units applied in systems possessing their own medium voltage
transformer are exempted from this norm.
All battery chargers marked PFC are fitted with harmonic filters when applied within the scope of the norm. The filter
is active at mains input voltage range 184 V - 264 V.

Features: - wide input voltage range for 30 W and 60 W units, 125 W and up input 230 VAC and/or 115 VAC
30W units available in 85 up to 265VAC (type...WL) or 195 up to 460VAC (type...W1L)
- output voltage 13,7, 27,4 or 54,8 VDC, over a wide range adjustable
- connection in parallel or series
- high efficiency
- compact and robust design in metal housing, 30 W units in plastic enclosure
- easy installation on DIN mounting rail, alternative screw fastening
- safety class I
- interference emission EN 55011 class B (industry), EN 55022 class B (Telecom)
- interference immunity EN 50082-2: ESD, electromagnetic irradiation, burst, conducted interference immunity,
mains voltage dips
- excess current limiter, short-circuit protection, overvoltage limitation and overtemperature protection
- inrush current limiter
- status display: LED
- all battery chargers series RPL can be also delivered as power supplies (type ...W)
- battery chargers 30 W, 60 W and 480 W can be applied without alterations as D.C./D.C.-converters

battery chargers
Chart:

Model Model Model Model Norm EN


Power Voltage/Current wide voltage input input input Article.-no. 61000-3-2
range 230/115VAC 230VAC 115VAC met
DC 13,7V / 2.5A RPL 122.5 WL 0520-0122.5WL Norm does not apply
30 W
DC 27,4V / 1.25A RPL 241.25 WL 0520-241.25WL Norm does not apply
(AC 85-265V)
DC 54,8V / 0.65A RPL 480.65 WL 0520-480.65WL Norm does not apply
DC 13,7V / 2.5A RPL 122.5 W1L 0520-0122.5W1 Norm does not apply
30 W
DC 27,4V / 1.25A RPL 241.25 W1L 0520-241.25W1 Norm does not apply
(AC 195-460V)
DC 54,8V / 0.65A RPL 480.65 W1L 0520-480.65W1 Norm does not apply
DC 13,7V / 5A RPL 1205 EL 0520-001205EL Norm does not apply
60 W DC 27,4V / 2.5A RPL 242.5 EL 0520-0242.5EL Norm does not apply
DC 54,8V / 1.25A RPL 481.25 EL 0520-481.25EL Norm does not apply
DC 13,7V / 10A RPL 1210 EL 0520-001210EL yes
125 W DC 27,4V / 5A RPL 2405 EL 0520-002405EL yes
DC 54,8V / 2.5A RPL 482.5 EL 0520-0482.5EL yes
DC 13,7V / 20A RPL 1220 EL 0520-001220EL no
250W DC 27,4V / 10A RPL 2410 EL 0520-002410EL no
DC 54,8V / 5A RPL 4805 EL 0520-004805EL no
DC 13,7V / 20A RPL 1220 PFCL 0520-001220PL yes
250W DC 27,4V / 10A RPL 2410 PFCL 0520-002410PL yes
DC 54,8V / 5A RPL 4805 PFCL 0520-004805PL yes
DC 27,4V / 20A RPL 2420 EL 0520-002420EL no
DC 54,8V / 10A RPL 48 10 EL 0520-004810EL no
480W DC 27,4V / 20A RPL 2420 E1L 0520-02420E1L no
DC 54,8V / 10A RPL 48 10 E1L 0520-04810E1L no
DC 27,4V / 20A RPL 2420 PFCL 0520-002420PL yes
480W DC 54,8V / 10A RPL 48 10 PFCL 0520-004810PL yes

Options: - other input- and output voltages possible


- units of lesser power, suitable also for application in telecom
- units with multiple output voltages
- overload and short circuit behavior can be realized to customer's requirements

Standard stock items Subject to technical modifications

C 1/17
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 18

Primary switched single-phase battery chargers


RPL 122.5 WL – 480.65 W1L comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
application as D.C./D.C.-converter possible
Technical data 30W 30W
Model RPL 12 2.5 WL RPL 24 1.25 WL RPL 48 0.65 WL RPL 12 2.5 W1L RPL 24 1.25 W1L RPL 48 0.65 W1L
INPUT
Rated input voltage, U1 rated AC 100V - 240V AC 220V - 400V
Voltage range, U1min - U1max AC 85V - 265V or DC 100V - 375V AC 195V - 460V or DC 230V - 650V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 460V
Rated current typical, I1 rated 0,32A at 230VAC ; 0,61A at 115VAC 0,32A at 230VAC ; 0,19A at 400VAC
Maximum transient pulse Ta = 25°C < 25A at 230VAC ; < 13A at 115VAC < 25A at 230VAC ; < 35A at 400VAC
Maximum transient pulse Ta = 55°C < 50A at 230VAC ; < 26A at 115VAC < 50A at 230VAC ; < 60A at 400VAC
Internal fuse T1.25A with high switch-off ability -
Recommended external fuse power circuit breaker C6, B10 power circuit breaker C6, B10
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 50ms at 230VAC ; > 10ms at 115VAC > 10ms at 230VAC ; > 20ms at 400VAC
Reverse polarity protection D.C.-input yes yes
OUTPUT
Rated voltage U2 rated D.C. DC 13,7V DC 27,4V DC 54,8V DC 13,7V DC 27,4V DC 54,8V
Voltage range U2 min - U2 max D.C. 10-15V 23-29V 45-58V 10-15V 23-29V 45-58V
Rated current I2 (at U2 rated) 2.25A 1.15A 0.6A 2.25A 1.15A 0.6A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical 2.25A 1.15A 0.6A 2.25A 1.15A 0.6A
Short circuit current typical < 5A < 3A < 2A < 5A < 3A < 2A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 10mV RMS < 10mV RMS
Mains stabilization U1 min - U1 max < 0,1 % < 0,1 %
battery chargers

Load stabilization load alteration < 0,5 % < 0,5 %


10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.03% / K < 0.03% / K
Operation in parallel and series yes yes
Status reports LED green LED green
DIRECTIVES
Mains harmonics limit EN 61000-3-2 not necessary not necessary
Interference emission EN 50081-1, EN 55011 class B, EN 55022 class B EN 50081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test voltage input/housing - -
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing - -
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 80% > 82% > 82% > 80% > 82% > 82%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature 0°C up to +55°C -20°C up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM5,08mm to screw
2-pole 0,75-2,5mm2 (+ -) 2-pole 0,75-2,5mm2 (+ -)
Housing design plastic plastic
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation vertical vertical
Approx. dimensions (W x H x D) 40 x 80 x 85 mm 40 x 80 x 85 mm
Approx. total weight 0,14kg 0,14kg

Subject to technical modifications Standard stock items


C 1/18
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 19

Primary switched single-phase battery chargers


RPL 1205 EL – 482.5 EL comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
60W units applicable as D.C./D.C.-converters
Technical data 60W 125W
Model RPL 12 05 EL RPL 24 2.5 EL RPL 48 1.25 EL RPL 12 10 EL RPL 24 05 EL RPL 48 2.5 EL
INPUT
Rated input voltage, U1 rated AC 100V - 240V AC 115V and AC 230V
Voltage range, U1min - U1max AC 90 - 264V or DC 120V - 375V AC 94 - 132V or AC 184 - 264V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 275V
Rated current typical, I1 rated 0.7 A at 230VAC ; 1.2A at 115VAC 1,3A at 230VAC ; 2,2A at 115VAC
Maximum transient pulse Ta = 25°C < 25A at 230VAC ; < 12A at 115VAC < 45A at 230VAC ; < 22A at 115VAC
Maximum transient pulse Ta = 55°C < 55A at 230VAC ; < 29A at 115VAC < 85A at 230VAC ; < 43A at 115VAC
Internal fuse T2.0A with high switch-off ability T6.3A with high switch-off ability
Recommended external fuse power circuit breaker C6, B10 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 50ms at 230VAC ; > 10ms at 115VAC > 20ms
Reverse polarity protection D.C.-input yes -
OUTPUT
Rated voltage U2 rated D.C. DC 13,7V DC 27,4V DC 54,8V DC 13,7V DC 27,4V DC 54,8V
Voltage range U2 min - U2 max D.C. 10,5-15V 21-29V 45-58V 9-15V 21-29V 45-58V
Rated current I2 (at U2 rated) 5.0A 2.5A 1.25A 10A 5A 2.5A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical < 8A < 4A < 2A < 11A < 6A < 3A
Short circuit current typical < 12A < 9A < 6A < 16A < 10A < 6A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 15mV RMS < 10mV RMS < 15mV RMS < 10mV RMS
Mains stabilization U1 min - U1 max < 0,15 % < 0,15 %

battery chargers
Load stabilization load alteration < 1,0 % < 0,5 % < 1,0 % < 0,5 %
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.02% / K < 0.02% / K
Operation in parallel and series series operation yes. For parallel operation extern yes
series diode necessary
Statusmeldungen LED - green LED - green
Noise output zero potential change-over contact yes yes
Temperature compensation (battery charger) 2,2k⍀-NTC (f. example Siemens B57045K222K) 2,2k⍀-NTC (f. example Siemens B57045K222K)
external NTC-resistor
DIRECTIVES
Mains harmonics limit EN 61000-3-2 not necessary yes
Interference emission EN 50081-1, EN 55011 class B, EN 55022 class B EN 50081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class 1
Test voltage input/housing 1500VAC RMS 50Hz, 1min 1500VAC RMS 50Hz, 1min
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 82% > 83% > 84% > 85% > 88% > 89%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature -40°C up to +55°C -40°C up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM5,08mm to screw
2-pole 0,75-2,5mm2 (+ -) 2-pole 0,75-2,5mm2 (+ -)
Connection noise output connector RM5,08mm to screw connector RM5,08mm to screw
temperature compensation 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2) 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2)
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation vertical any position
Approx. dimensions (W x H x D) 51 x 121 x 81 mm 66 x 148 x 113 mm
Approx. total weight 0,36kg 0,84kg
Standard stock items Subject to technical modifications

C 1/19
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 20

Primary switched single-phase battery chargers


RPL 1220 PFCL – 4810 PFCL comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
480W units applicable as D.C./D.C.-converters
Technical data 250W 480W
Model RPL 12 20 PFCL RPL 24 10 PFCL RPL 48 05 PFCL RPL 24 20 PFCL RPL 48 10 PFCL
INPUT
Rated input voltage, U1 rated AC 115V and AC 230V AC 230V
Voltage range, U1min - U1max AC 94 - 132V or AC 184 - 264V AC 196-264V or DC 270V-375V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 275V
Rated current typical, I1 rated 1,9A at 230VAC ; 4,2A at 115VAC 3,1A at 230VAC
Maximum transient pulse Ta = 25°C < 35A at 230VAC ; < 17A at 115VAC < 11A at 230VAC
Maximum transient pulse Ta = 55°C < 69A at 230VAC ; < 33A at 115VAC < 30A at 230VAC
Internal fuse T6,3A with high switch-off ability T6,3A with high switch-off ability
Recommended external fuse power circuit breaker B10, B16 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 20ms > 30ms
Reverse polarity protection D.C.-input - yes
OUTPUT
Rated voltage U2 rated D.C. DC 13,7V DC 27,4V DC 54,8V DC 27,4V DC 54,8V
Voltage range U2 min - U2 max D.C. 9-15V 21-29V 45-58V 23-29V 45-58V
Rated current I2 (at U2 rated) 20A 10A 5A 18A 9A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical < 22A < 11A < 6A 18A 9A
Short circuit current typical < 27A < 14A < 7A < 22A < 12A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 15mV RMS < 10mV RMS < 60mV RMS
Mains stabilization U1 min - U1 max < 0,15 % < 0,05 % < 0,15 %
battery chargers

Load stabilization load alteration < 1,0 % < 0,5 % < 0,25 %
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.02% / K < 0.02% / K
Operation in parallel and series yes yes
Status reports LED green LED green
Noise output zero potential change-over contact yes no
Temperature compensation (battery charger) 2,2k⍀-NTC (f. example Siemens B57045K222K) -
external NTC-resistor
DIRECTIVES
Mains harmonics limit EN 61000-3-2 yes yes
Interference emission EN 50081-1, EN 55011 class B, EN 55022 class B EN 50081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test voltage input/housing 1500VAC RMS 50Hz, 1min 1500VAC RMS 50Hz, 1min
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 85% > 89% > 90% > 92%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature -40°C up to +55°C 0°C up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM5,08mm to screw
4-pole 0,75-2,5mm2 (++ --) 4-pole 0,75-4,0mm2 (++ --)
Connection noise output connector RM5,08mm to screw -
temperature compensation 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2)
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation any position front plate horizontal, connections below
Approx. dimensions (W x H x D) 75 x 173 x 122 mm 245 x 138 x 100 mm
Approx. total weight 1,5kg 2,4kg

Subject to technical modifications Standard stock items


C 1/20
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 21

Primary switched single-phase battery chargers


RPL 1220 EL – 4810 E1L comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
480W * units applicable as D.C./D.C.-converters
Technical data 250W 480W
Type RPL 12 20 EL RPL 24 10 EL RPL 48 05 EL RPL 24 20 EL* RPL 48 10 EL* RPL 2420 E1L RPL 4810 E1L
INPUT
Rated input voltage, U1 rated AC 115V and AC 230V AC 230V AC 115V
Voltage range, U1min - U1max AC 94 - 132V or AC 184 - 264V AC 196-264V / DC 270V-375V AC 93-132V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 275V varistor AC 275V varistor AC 150V
Rated current typical, I1 rated 2,5A at 230VAC ; 4,2A at 115VAC 3,6A at 230VAC 5,6A at 115VAC
Maximum transient pulse Ta = 25°C < 35A at 230VAC ; < 17A at 115VAC < 11A at 230VAC < 11A at 115VAC
Maximum transient pulse Ta = 55°C < 69A at 230VAC ; < 33A at 115VAC < 30A at 230VAC < 30A at 115VAC
Internal fuse T6,3A with high switch-off ability T6,3A with high switch-off ability
Recommended external fuse power circuit breaker B10, B16 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 20ms > 40ms at 230VAC > 40ms at 115VAC
Reverse polarity protection D.C.-input - yes
OUTPUT
Rated voltage U2 rated D.C. DC 13,7V DC 27,4V DC 54,8V 27,4V 54,8V 27,4V 54,8V
Voltage range U2 min - U2 max D.C. 9-15V 21-29V 45-58V 23-29V 45-58V 23-29V 45-58V
Rated current I2 (at U2 rated) 20A 10A 5A 18A 9A 18A 9A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical < 22A < 11A < 6A 18A 9A 18A 9A
Short circuit current typical < 27A < 14A < 7A < 22A < 12A < 22A < 12A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 15mV RMS < 10mV RMS < 60mV RMS
Mains stabilization U1 min - U1 max < 0,15 % < 0,05 %

battery chargers
Load stabilization load alteration < 1,0 % < 0,5 % < 0,25%
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0.02% / K < 0,02% / K
Operation in parallel and series yes yes
Status reports LED green LED green
Noise output zero potential change-over contact yes -
Temperature compensation (battery charger) 2,2k⍀-NTC -
external NTC-resistor (f. example Siemens B57045K222K)
DIRECTIVES
Mains harmonics limit EN 61000-3-2 no no not necessary
Interference emission EN 50081-1, EN 55011 class B, EN 50081-1, EN 55011 class B,
EN 55022 class B EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test mark / approbation - cUL - -
Test voltage input/housing 1500VAC RMS 50Hz, 1min 1500VAC RMS 50Hz, 1min
Test voltage input/output 3000VAC RMS 50Hz, 1min 3000VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark no no not necessary
OPERATING DETAILS
Efficiency typical > 85% > 89% > 90% > 92%
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature -40°C up to +55°C 0 up to +55°C
Storage temperature -40°C up to +85°C -40°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
3-pole 0,75-2,5mm2 (L1-N-PE) 3-pole 0,75-2,5mm2 (L1-N-PE)
for D.C./D.C.-converter: + on L1, - on N
Connection output voltage connector RM5,08mm to screw connector RM7,62mm to screw
4-pole 0,75-2,5mm2 (+ -) 4-pole 0,75-4,0mm2 (+ + - -)
Connection noise output connector RM5,08mm to screw -
temperature compensation 5-pole 0,75-2,5mm2 (COM-NO-NC-1-2)
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation any position front plate horizontal, connections below
Approx. dimensions (W x H x D) 75 x 173 x 122 mm 245 x 138 x 100 mm
Approx. total weight 1,5kg 2,0kg
Lagertypen Technische Änderungen vorbehalten
C 1/21
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 22

Pulse battery chargers


RLEC 2403S, 2405S and 2410S comp. to VDE 0570 part 2-6, EN 61558-2-6
RLEC 1220, 2420, 1240 and 2440 comp. to VDE 0570 part 2-6, EN 61558-2-6

The battery chargers series RLEC apply the ECS charging system which, in conjunction with our patented switching
concept, is considered the optimum charging method available at present. All stock items are adjusted to NiCd-accumu-
lators. Internal programming on manufacturer´s part permits both maintenance-free lead acid and NiCd storage batte-
ries as well as open Pb-batteries to be charged 100% without prior discharging.

The ECS charging system adapts itself perfectly to the individual nature of the battery to be charged, so any exemplary
leakage or the history of the battery become irrelevant. The battery itself controls the charging process, because the
momentary state of the battery is measured continually and charging is controlled according to these measured va-
lues. This way the battery always draws the exact amount of energy it is able to store at the moment. This results in high
efficiency without causing any damaging heat to the cells. Moreover charging time is reduced considerably as the
charging process constantly adapts to the amount of energy the battery can absorb.

The battery's number of charging cycles is increased significantly which in turn increases battery's service life consider-
ably.

Even older batteries can be regenerated with the ECS charging method as the charging pulses format the individual
cells and remove sulfating, minimizing the memory effect.

Precise determination of the end of charging process prevents short-time overcharging of battery. That way repeated
attempts to recharge full batteries are detected and do not lead to detrimental overcharging. When the charging pro-
cess has been completed the charger continues to take care of the battery, monitoring it continuously and providing
the ideal float charge. The battery is always ready for use.

Buffer-battery system is fully guaranteed, i.e. energy can also be drawn during mains connection. The reverse current
is <=1mA during switch off.
battery chargers

LEDs for visual control of charging progress .

Example of charging cycles:

Battery with
Akkua Nennkapazität
rated capacity of 1000 mAh
1000mAh

1000

980
900

800

770
700

600
620
(mAh)

500
500
400

300

200

100

0
before
vorher 1 2 3

Subject to technical modifications Standard stock items


C 1/22
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 23

Pulse battery chargers


RLEC 2403S, 2405S and 2410S comp. to VDE 0570 part 2-6, EN 61558-2-6
RLEC 1220, 2420, 1240 and 2440 comp. to VDE 0570 part 2-6, EN 61558-2-6

Symbolic diagram of the charging process:

yellow green

Cell temperature
charge voltage (V)

Temperature
at dU/dt
switch-off

ECS charging method

Float charge
charge current (A)

battery chargers
Current pulse
Float charge
Measuring

Advantages: · Process-controlled fast charging to full capacity


· Innovative process prevents memory effect and regenerates batteries
· Up to 10 000 cycles possible
· Independent from charging condition
· Adapts charging precisely to battery's condition
· Automatic temperature control
· Automatic monitoring of charge voltage and charge amount
· Automatic termination of charging process
· Automatic intelligent float charge
· Reduces charging time considerably
· Automatic overcharge protection
· Short circuit proof and reverse polarity protected
· Significant increase of battery's service life
· Cost reduction due to battery's prolonged service life
· Available for NiCd or lead acid batteries

Series RLEC...S
As an optional extra, the battery chargers can be equipped with a centralized alarm via zero potential contact (contact is closed
during battery charging).
On request the chargers can also be provided for different cell quantities
(Pb max. 12 cells, NiCd max. 20 cells)

The battery chargers come in a compact plastic housing that provides comprehensive protection against accidental contact and
meets safety requirements for protection against electric shock comp. to VDE 0106 part 101.
The housing is designed for snap-on attachment to DIN EN 50022 rails for easy mounting.

Series RLEC
The battery chargers are fitted into a robust plastic-coated steel housing.

Standard stock items Subject to technical modifications

C 1/23
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 24

Pulse battery chargers


RLEC 2403S, 2405S and 2410S comp. to VDE 0570 part 2-6, EN 61558-2-6

RLEC 2403S RLEC 2405S RLEC 2410S

Technical data for model RLEC 2403S RLEC 2405S RLEC 2410S
Input
Mains input voltage AC 230V or AC 400V
Mains input voltage range + 10 % to - 10 % comp. to DIN IEC 38
Frequency 50Hz / 60Hz
Input fuses 5 x 20 mm 5 x 20 mm 5 x 20 mm
AC 230V 1,25 A time lag 2,5 A time lag 4,0 A time lag
AC 400V external external external
Output
Battery rated voltage DC 24 V DC 24 V DC 24 V
Max. charge current DC 3 A DC 5 A DC 10 A
battery chargers

Battery type NiCd batteries (factory internal programming for Pb-batteries possible)
Status display two-color LED yellow: charging / green: charged
red LED trouble (battery defective or outside tolerance range)
Charging characteristic ECS method in conjunction with patented switching concept
Temperature control during charging charge dependent on battery temperature
Overload protection via internal electronic current limiter
Reverse current when mains off, I =< 1mA
Reverse polarity protection integrated (reverse polarity current < 1mA)
Overtemperature protection automatic cut-off if battery or electronics overheats
RFI suppression better than EN 55011 class B
Temperature range 0° C to + 40° C
General data
Transformer test voltage between input and output comp. to regulation (safety transformer)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61131-2/part 2
CE-mark yes
Installation orientation vertical
Cooling convection
Type of connection PC terminals
Connection data fine strand max. 2,5mm2
Mounting on DIN EN 50022 mounting rail, spacing > 8mm
Protection rating comp. VDE 0470 IP 20
Protection class comp. VDE 0106 T1 prepared for protection class II
Insulation class E
Dimensions in mm approx.
(Length/Width/Depth) 82 x 90 x 153 134 x 125 x 175 134 x 125 x 175
Mounting template in mm, approx. - 87 x 120 87 x 120
Article no. AC 230 V 0239-0002403S 0239-0002405S 0239-0002410S
AC 400 V 0240-0002403S 0240-0002405S 0240-0002410S
Copper weight in kg 0,97 1,18 1,18
Weight in kg 2,5 4,3 4,5

Subject to technical modifications Standard stock items


C 1/24
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 25

Pulse battery chargers


RLEC 1220, 2420, 1240 and 2440 comp. to VDE 0570 part 2-6, EN 61558-2-6

RLEC 1220 RLEC 2440

Technical data for model RLEC 1220 RLEC 2420 RLEC 1240 RLEC 2440
Input
Mains input voltage AC 230V
Mains input voltage range + 10 % to - 10 % comp. to DIN IEC 38
Frequency 50Hz / 60Hz
Input fuses 230V ETA 3 A ETA 5 A ETA 5 A ETA 8 A
Output

battery chargers
Battery rated voltage DC 12V DC 24V DC 12V DC 24V
Max. charge current 20ADC 20ADC 40ADC 40ADC
Battery type lead acid or NiCd batteries (battery type can be programmed internally)
Status display green charged
LEDs yellow charging
red trouble (battery defective or outside temperature range)
Charging characteristic ECS method in conjunction with patented switching concept
Temperature control during charging charge dependent on battery temperature
Overload protection via internal electronic current limiter
Reverse current when mains off, I =< 1mA
Reverse polarity protection integrated (reverse polarity current < 1mA)
Overtemperature protection automatic cut-off if battery or electronics overheat
RFI suppression better than EN 55011 class B
Temperature range 0° C to + 40° C
Efficiency 90 %
General data
Transformer test voltage between input and output comp. to regulation (safety transformers)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61131-2/part 2
CE-mark yes
Installation orientation any position
Cooling convection forced air
Type of connection terminal blocks (protected against finger touch comp. to VBG 4)
Connection data fine strand fine strand
primary max. 4 mm2 primary max. 4 mm2
secondary max. 10 mm2 secondary max. 16 mm2
Mounting integrated mounting brackets
Protection rating comp. VDE 0470 IP 20
Protection class comp. VDE 0106 T1 I
Insulation class E
Dimensions in mm approx.
(Length / Width / Height) 210 / 225 / 190 195 / 315 / 175 195 / 315 / 175 240 / 350 / 195
Mounting template in mm, approx. 200 / 115 290 / 125 290 / 125 330 / 140
Article no. Pri. 230V 0237-230-012-01 0237-230-024-02 0237-230-012-03 0237-230-024-04
Pri. 400V 0238-400-012-01 0238-400-024-02 0238-400-012-03 0238-400-024-04
Copper weight in kg 1,03 1,68 1,68 2,50
Weight in kg 8,00 15,00 15,00 18,00

Standard stock items Subject to technical modifications

C 1/25
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 26

Intelligent Automatic Charger


RALG 240 comp. to VDE 0570 part 2-6, EN 61558-2-6

Product description
RALG 240G car battery charger is an individual development for motorcar application. It is a universal automatic char-
ger for 12V, 24V and 42V batteries with a maximal charging power of 240 Watt.
Its integrated intelligence recognizes the battery´s voltage level and adjusts to optimal charging characteristic acc. to
ECS-method.

Essential features:
- Fast and gentle battery charging
- Optimized charging process, optimized charging current
- Avoids overcharge via float charge
- Reverse polarity protection
- Automatic ON/OFF, i.e. minimizes sparking / fire hazards or damage to
battery poles
- Extensive protection mechanisms, such as overtemperature switch-off,
undervoltage switch-off, reference control and comparison setpoint and
actual values
- Other designs available, for example as wall- or base frame unit
Technical data for model RALG 240
Input
Mains input voltage AC 230V
battery chargers

Mains input voltage range + 10 % to - 10 % comp. to DIN IEC 38


Recommended fuse protection on line side line circuit breaker C6, B10
Frequency 50Hz / 60Hz
Output
Battery rated voltage DC 12V, DC 24V and DC 42V
Maximal charging current 5ADC Puls@42V, 10ADC Puls@24V and 12V
Battery type lead acid accumulators 6, 12, 21 cells (12V, 24V, 42V) 20 up to 400 Ah
Reverse current at line off, I =< 0,1% IMAX
Status LED report LED orange operation on
LED blue pulse
LED green charged
LED yellow charging
LED red battery or charger defect
Display for battery voltage display
Characteristic – charging method ECS-charging method in connection with patented switching concept
Temperature control during charging charging according to ambient temperature
Overtemperature protection automatic switch-off at overtemperature of battery resp. electronics
Overload protection via internal electronic current limitation
Reverse polarity protection integrated (reverse polarity current < 1mA)
RFI suppression better than VDE 0871, limit curve B
General data
Battery rated voltage DC 12V, DC 24V and DC 42V
Test voltage input / output 4000VAC RMS 50Hz, 1min
Regulations VDE 0570 part 2-6, EN 61558-2-6, EN 61131-2/part 2
Line harmonics limitation EN 61000-3-2
Interference emission EN 550081-1, EN 55011 class B, EN 55022 class B
Interference immunity EN 50082-2
Safety EN 60950, IEC 950
CE-mark yes
Protection rating comp. VDE 0470 / EN 60529 IP32 metal housing
Protection class comp. IEC 536, VDE 0106 T1 I
Insulation class E
Connection primary earthing contact plug
secondary cable with battery terminals
Cooling natural convection
Installation orientation any position
Measurements in mm (L/W/H) 320/200/134 mm
Operation temperature range full power -20ºC...+50ºC
Storage temperature -25ºC...+85°C
Mounting template in mm (L/W) 157/183
Article no. 0270-0000240G
Weight 6 kg

Subject to technical modifications Short-term delivery


C 1/26
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 27

DC - UPS modules
RDCUSV 3S to RDCUSV 50S

Product description
We are faced daily with trouble in our mains supply systems which can add up to 10% of total operation time. Fluctua-
tions and voltage dips occur, occasionally even total power failures, for example caused by strokes of lightning or faulty
maintenance. A suitable UPS-system (Uninterruptible Power Supply) provides protection against such faults.
According to EN 61131-2 / part 2 (limit values for rated D.C. voltage at DC 24 V) the currently valid operational voltage for
electronic controls is DC 24V (DC 20.4V - DC 28.8V RMS). Power packs have to be designed accordingly.
In connection with our D.C. power supplies we produce DC UPS modules for such cases. They can be connected easi-
ly secondary in parallel, thereby providing reliable protection for your control units.
The patented technology of our UPS modules make switching controllers such as boost choppers unnecessary. EMC
problems therefore do not occur.
All Riedel-UPS modules, inclusive battery, are fitted into compact housings and easy to mount.
The DC UPS modules can be snapped onto mounting rails according to DIN EN 50022. The module is available in ver-
sions 24 VDC 3A 30s, 24 VDC 10A 30s, 24 VDC 20A 30s and 24 VDC 40A 30s. Other types are available on request.
For application the module is to be connected in parallel to the D.C. voltage output of a DC 24V power pack (see sche-
matic diagram) and the "OFF" terminal is connected to the minus terminal.
When switching off this "OFF"-contact must be opened via the auxiliary contact of the main switch, so that the UPS-module
is deactivated!

UPS
The module's electronics monitors the output voltage and switches the battery on when previously set threshold value
(22VDC) is not reached. The internal battery serves as supply source for the power consumer over a defined period
(up to 30 seconds) providing a maximum current of 3A, 10A, 20A or 40A which is limited internally. The output voltage is
stabilized to a threshold value of 22 VDC (see diagram).
LEDs provide a visual indicator, signaling Ready (green), UPS-operation (yellow) and battery undervoltage (red). A zero
potential contact opens when UPS-operation begins, so signaling a mains power failure.
For control of the UPS module an input terminal is provided, which must be connected to the minus-terminal to activate the
module.
For non-stabilized D.C. supplies we offer a more reasonable version of DC UPS modules, featuring an activation thres-
hold voltage of 20.6VDC. At 20.6VDC the output voltage of the module is still within limit values for D.C. voltage of
24VDC comp. to EN 61131-2 / part 2 in the event of UPS activation.
The standard product range can be extended to include custom designs.

Standard stock items Subject to technical modifications

C 1/27
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 28

DC - UPS modules
RDCUSV 3S to RDCUSV 50S

Construction - Plastic enclosure for snap-on mounting (DIN EN 50022)


- LED status display on front
• Ready: green LED - UPS is ready to provide current
• Run: yellow LED - battery is providing current
• Charge: red LED - battery voltage is too low
- Zero potential signal output via screw-type terminals
• UPS active: battery is providing current
contact opens
- Input to switch on the UPS function via screw-type terminal
Connect OFF-terminal to minus terminal for switch on

Function - In the event of mains failure, stabilized output voltage (22 VDC resp. 20.6 VDC)
- Short circuit proof
- Automatic cut-off in the event of:
• overtemperature
• low battery voltage (17 VDC)
- Automatic charging
• IU characteristic

Option Switch off back-up time limit for longer UPS-times


Maximal back-up capacities on request

Back-up times
RDCUSV 3S RDCUSV 10S / 16S RDCUSV 20S /30S RDCUSV 40S / 50S
6 min 2,8 A 8,0 A 21,0 A 22,0 A
10 min 1,9 A 5,9 A 16,0 A 17,0 A
30 min 0,8 A 2,3 A 6,0 A 7,0 A
60 min 0,5 A 1,8 A 3,8 A 4,2 A
120 min 0,3 A 0,75 A 2,0 A 2,6 A
UPS

240 min 0,17 A 0,4 A 1,0 A 1,6 A

Top view
Discharge time in min

Discharge current in A

Discharge characteristic Example RDCUSV 10S

Subject to technical modifications Standard stock items


C 1/28
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 29

DC - UPS modules
RDCUSV 3S to RDCUSV 50S

RDCUSV 3S RDCUSV 10S, RDCUSV 16S RDCUSV 20S, RDCUSV 30S RDCUSV 40S, RDCUSV 50S

Version for activation threshold 22 VDC:


Technical data RDCUSV 3S RDCUSV 10S RDCUSV 20S RDCUSV 40S
Max. current drain 3 ADC 10 ADC 20 ADC 40 ADC
Back-up time at max. current adjusted by Riedel to 30 s (other back-up times optional)
Maximum current pick-up ≤ 0,3 A ≤1A ≤2A 3 A
after total discharge
Back-up ready for 1 cycle after 5 mins.
after total discharge
Charging system IU characteristic
Activation threshold 22 VDC
Total discharge protection switch-off threshold 17 VDC
Type of battery lead acid
Signal output zero potential, load up to 24 VDC / 50 mA
Ambient temperature 0– 40°C
General data
CE-mark yes
Installation orientation any position
Type of connection P.C. terminals
Connection data fine strand, max. 2,5mm2 fine strand, max. 4mm2
Mounting mounting rail (DIN EN 50 022), spaced > 8mm

UPS
Protection rating comp. VDE 0470 IP 20
Protection class comp. VDE 0106 T1 SELV
Weight in kg approx. 0,9 approx. 3,5 approx. 4,4 approx. 6,5
Article no. 22,0 V 0250-0000003S 0250-0000010S 0250-0000020S 0250-0000040S
Dimensions in mm (L/W/H) 82 / 90 / 120 134 / 125 / 150 157 / 175 / 185 200 / 180 / 185

Version for activation threshold 20,6 VDC:


Technical data RDCUSV 3S RDCUSV 10S RDCUSV 16S RDCUSV 20S RDCUSV 30S RDCUSV 40S RDCUSV 50S
Max. current drain 3 ADC 10 ADC 16 ADC 20 ADC 30 ADC 40 ADC 50 ADC
Back-up time at max. current adjusted by Riedel to 30 s (other back-up times optional)
Maximum current pick-up ≤ 0,3 A ≤1A ≤2A ≤3A
after total discharge
Back-up ready for 1 cycle after 5 mins.
after total discharge
Charging system IU characteristic
Activation threshold 20,6 VDC
Total discharge protection switch-off threshold 17 VDC
Type of battery lead acid
Signal output zero potential, load up to 24 VDC / 50 mA
Ambient temperature 0– 40°C
General data
CE-mark yes
Installation orientation any position
Type of connection P.C. terminals
Connection data fine strand, max. 2,5mm2 fine strand, max. 4mm2
Mounting mounting rail (DIN EN 50 022), spaced > 8mm
Protection rating comp. VDE 0470 IP 20
Protection class comp. VDE 0106 T1 SELV
Weight in kg approx. 0,9 approx. 3,5 approx. 4,4 approx. 6,5
Article no. 20,6 V 0251-0000003S 0251-0000010S 0251-0000016S 0251-0000020S 0251-0000030S 0251-0000040S 0251-0000050S
Dimensions in mm (L/W/H) 82 / 90 / 120 134 / 125 / 150 157 / 175 / 185 200 / 180 / 185

Standard stock items Subject to technical modifications

C 1/29
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 30

DC - UPS module
RIPCUSV 5S supply for industrial PCs (IPC)

Product description:
RIPCUSV 5S complements series RDCUSV. RIPCUSV-modules are equipped with a serial interface, which, connected to a 24VDC
supplied industrial-PC (IPC) and the operation system Microsoft Windows NT/2000/XP, enables setup of a computer controlled non-
interruptible power supply. Communication between UPS and IPC takes place via interface, i.e. the IPC receives a signal after UPS-ti-
me limit has been reached. The IPC then closes the system. As soon as the computer has shut down the UPS receives a report and in
turn shuts off the computer's supply voltage.
The patented method of DC-UPS-modules makes any application of switching controllers, for example boost choppers, unnecessa-
ry. EMC-problems do not occur.
All Riedel IPC-UPS-modules are installed together with the accumulator in compact housings and are easy to assemble. IPC-UPS-
modules are snapped onto supporting rails according to DIN EN 50022. For operation connect them to the DC-output of the DC 24V-
power supply (see block diagram) and connect terminal "AUS / OFF" with the minus-terminal.
The module's electronics guards the output voltage and switches on the accumulator when pre-adjusted threshold (20,6VDC) falls
short. The internal accumulator serves as supply source to the consumer for a defined time range with 5A maximal current, which is li-
mited internally. The output voltage will be controlled to threshold value (20,6VDC). For visual control LEDs signal readiness (green),
UPS-operation (yellow) and accumulator undervoltage (red).
Construction: - Plastic housing for snap-on assembly (DIN EN 50022)
- Unit status display via LED on front side
• Ready: LED green - UPS can deliver current
• Operation: LED yellow - accu delivers current
• Accu is charging: LED red - undervoltage accu
- Opening for UPS switch-on via screw-terminal
For switch-on connect terminal "AUS / OFF" with minus-terminal
Function: - During power-line failure stabilized output voltage ( 20,6 VDC)
- Boot time bridging adjustable (2-3-4-5min)
- Adjustable UPS-time (0,5 up to 30s), after that signal to IPC via interface
- UPS switch-off via signal from computer;
automatic switch-off after adjustable waiting period (4-6-8-10min)
- Short circuit proof
- Automatic switch-off at:
• · Undervoltage accu (17 VDC)
- Automatic charge
• · IU-characteristic
UPS

Article no.: 0254-0000005S

Accu-packs
Series RAP in 2Ah, 5Ah, 7Ah

In general:
The compact and space-saving industrial design of the enclosed accu-packs series RAP
provides comprehensive protection against accidental contact. The units snap easily on-
to DIN EN 50022 mounting rails and can be fixated additionally with screws. Units of the
same type can be switched in parallel or in series.
Riedel-accu-packs contain valve compatible, maintenance free industrial lead acid batte-
ries showing high current delivery which originally had been specially developed for appli-
cation in danger report systems, emergency lighting, medicine, alarms, non-interruptible po-
wer supplies and Telecom-systems.
The accu-packs can be fitted in any position except upside down. Do not operate these
units in upside down position.
Input and output are protected with flat-plug fuses readily available all over the world.

Other capacities on request

Model Power Voltage Article No. Approx. dimensions in mm


Ah VDC Length Width Depth
RAP 24/2Ah 2 24 0253-000002Ah 125 135 160
RAP 24/5Ah 5 24 0253-000005Ah 175 150 180
RAP 24/7Ah 7 24 0253-000007Ah 200 180 180
Subject to technical modifications Short-term delivery
C 1/30
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 31

Power supplies
with back-up battery
RADA 4730 - RADA 4990
Features:
- 12VDC and 24VDC - Small size
- Safe design - EMC EN55022B
- Temperature controlled - Total discharge protection
- Signal power line failure - Mains connection via clamp terminal or screw terminal
- 15A output switch - Optional sabotage switch against undue opening of housing

Article numbers:
RADA 4730 = 0260-00004730 RADA 4980 = 0260-00004980 RADA 4990 = 0260-00004990
RADA 4740 = 0260-00004740 RADA 4570 = 0260-00004570

Technical data
INPUT
Input range 184...264 VAC
Frequency 45...65Hz
Efficiency (Uin = 230 VAC, 100% load) 12V 24V 48V
RADA 4730 85% RADA 4740 87% RADA 4570 87%
RADA 4980 88% RADA 4990 89%
Protection EN 60950 class 1
Insulation input / grounding 1500 VAC RMS 50Hz, 1min
input / output 3000 VAC RMS 50Hz, 1min
output / grounding 500 VDC
EMC EN 55022 class B
Inrush current limited via 7R NTC-resistor
Overvoltages protected via 275V 72J VDR-resistor
Input fuse RADA 4830 and RADA 4570 T6.3A, all others T4A
CE-mark yes
OUTPUT 12V 24V 48V
Charge voltage (50% load) 13.7 V 27.3 V 54.6 V
Output adjustment (select) 11...15 V 23...29 V 45…58VDC
Minimum voltage (total discharge protection) 10V±0.3V 20V±0.5V 40V±0.5V
Ripple voltage (f = 20Hz...300kHz, Tamb = 25°C) < 15mVrms < 15mVrms < 15mVrms
Load stabilization (Iout = 10...100%) ±1.5 % ±1 % ±0.5 %
Mains stabilization (Uinmin...Uinmax) ±0.1 % ±0.1 % ±0.1 %
Output current, charger 10 A 5 A (4740), 10A (4980) 2.5A (4570), 5A (4990)
Current limiting, charger < 11 A < 6 A (4740), < 11A (4980) < 3 A (4570), < 6A (4990)
Short circuit limitation, charger and battery Fuse 15A
OUTPUT 12V 24V 48V

Others
Battery capacity 14Ah 7Ah 2Ah
Battery type / Yuasa NP 7-12 7Ah 12V NP 7-12 7Ah 12V NP 2-12 2Ah 12V
UPS-time (approx. values) 10A / 45min, 2A / 5h 5A / 45min, 1A / 5 h 2A / 25 min, 0.5A / 2.5 h
Temperature compensation for battery 2k2 NTC-resistor
Total discharge protection for battery trigger at 10V trigger at 20V trigger at 40V
DISPLAYS AND ALARM REPORTS
Charger output OK green LED is on
Power line failure zero potential opening and closing relay contact, relay 24VDC/0.3A or 30VAC/0.5A
Sabotage switch against undue opening of housing microswitch, opening and closing contact
MECHANICS
Measurements RADA 4740, 4980, 4990 wall / 188 x 317 x 110mm
RADA 4730, 4570 wall / 188 x 277 x 110mm
Installation wall / screw connection
Weight without batteries <3kg (with batteries 12V/8kg, 24V/8kg, 48V/5kg)
Shutting of door with tool (screw driver)
Enclosure steel housing IP21
OPERATING CONDITIONS
Operating temperature -40°C...+55°C without batteries (-20°C...+45°C with standard batteries)
Humidity 85% RH IEC68-2-30
Cooling convection
CONNECTIONS
Input RADA 4740, RADA 4980, RADA 4990 2,5mm2 3-pole screw terminal (L-N-PE)
RADA 4730, RADA 4570 6mm2 3-pole screw terminal (L-N-PE)
All types cable inlet on top, incl. 1,5 m line cable
Output RADA 4740, 4980, 4990 2,5mm2 9-pole screw terminal (++, - -, alarm, battery)
2,5mm2 2-pole screw terminal (door alarm)
RADA 4730, 4570 6mm2 8-pole screw terminal (+, -, alarm, door alarm)
All types cable inlet on top

Short-term delivery Subject to technical modifications

C 1/31
C_TEIL_041018.qxd 19.10.2004 10:32 Seite 32

Voltage monitoring modules


Series RCV

Unit name: RCV: Riedel Control Voltage

Application: Monitoring DC voltage

Features: - Compact modern industrial design


- Fits DIN EN 50022 mounting rail
- Connections finger-safe and back of hand safe comp. VBG 4 accident prevention regu-
lations
- Simple installation
- Analysis via alarm contact (change-over contact)
- Relay remains closed as long as voltage is within tolerance range
- Zero potential contact, load capacity up to 200mA/230VAC
- Green LED remains on as long as relay is closed
- RCVU: monitors undervoltage
- RCV: monitors both under- and overvoltage

Technical data RCVU 24 VS RCV 24 VS


monitors undervoltage only monitors under- and overvoltage
Operation voltage DC 24 V DC 24 V
Current consumption Relay closed < 30mA Relay closed < 30mA
Relay released < 3mA Relay released < 3mA
Temperature drift < 0,01% < 0,01%
Others

Tolerance < 0,1% < 0,1%


Reverse polarity protection yes yes
Type of connection P.C. terminals P.C. terminals
Article no. 0252-00000001 0252-00000002
Dimensions in mm
Width / length / depth 22 / 79 / 84 22 / 79 / 84

Application example:
Protection against total
discharge

Power
RLG 2405 RCV
consumer

Subject to technical modifications Standard stock items


C 1/32
D
Copyright: BMW/Siemens/Riedel Product group

Robots manufacture cars - automation is common. The application


of modern technology not only makes production economic, it also
leads to more tolerable jobs and long-lasting, reliable vehicles. The
economic production of reliable products at state-of-the art techno-
logy is part and parcel of our company's philosophy – a good reason
for the car industry and their suppliers to use Riedel products.
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 2

Three-phase compact rectifier transformers


Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRK 2,5 – 60

Standard version: with connected three-phase bridge rectifier,


input 3 x 380/400/420 V, output 24 VDC, residual ripple < 5%
Capacitor version: with connected three-phase bridge rectifier and capacitor
input 3 x 380/400/420 V, output 24 VDC, residual ripple < 2%
Series RDRK has been developed specially for application in programmable logic
controllers (PLC). The transformers are well dimensioned and voltage stable allo-
wing for particular flat characteristic between no-load and load. Over- or undervol-
tages, critical for PLCs, do not occur even at increased mains voltage fluctuations.
Series RDRK is equipped with strongly oversized profile heat sinks that guarantee
intensified heat dissipation. Its rectifiers are protected against temporary current
surges and voltage spikes.
The capacitor version is protected via a mini circuit board containing a matching va-
ristor, foil capacitor and discharge resistor.
Harmonic rule EN 61000-3-2 is observed.
Design: Open vertical design, stationary, for installation and set-up in dry rooms, separate
Power packs

windings, sturdy mounting brackets. All connections via non-tracking terminal


blocks with screw connections. The terminals are protected against finger touch or
contact with the back of the hand in compliance to accident prevention regulations
(VBG 4).
IP 00, suitable for installation up to protection rating IP 23, insulation class E, max.
ambient temperature ta40°C, color grey, heat sink black anodized.
Capacitor versions show a slight diversion from stated measurements but attach-
ments remain the same.
Further designs available on request (fuses, voltages, connections, etc.)

3x 380/400/420 V 3x 380/400/420 V
Copper Total
Model Current 24 VDC 24 VDC Approx. dimensions in mm
weight weight
without capacitor with capacitor
A DC Article-no. Article-no. kg kg a b c d e f Attachment
RDRK 2,5 2,5 21–400–024–0 1 21–400–024–K0 1 0,70 2,50 130 75 160 84 46 45 M 5
RDRK 5 5 21–400–024–0 2 21–400–024–K02 0,80 3,00 130 85 165 84 56 45 M 5
RDRK 7,5 7,5 21–400–024–03 21–400–024–K03 1,20 4,40 155 70 195 90 55 55 M 5
RDRK 1 0 10 21–400–024–04 21–400–024–K04 1,40 6,00 155 85 195 90 70 55 M 5
RDRK 1 6 16 21–400–024–05 21–400–024–K05 2,30 7,00 190 170 165 128 72 60 M 6
RDRK 20 20 21–400–024–06 21–400–024–K06 2,50 8,40 190 180 165 128 82 60 M 6
RDRK 25 25 21–400–024–07 21–400–024–K07 3,00 1 1 ,30 190 190 165 128 92 70 M 6
RDRK 30 30 21–400–024–08 21–400–024–K08 4,00 1 1 ,40 190 190 165 128 92 70 M 6
RDRK 40 40 21–400–024–09 21–400–024–K09 4,80 17,10 230 190 210 176 71 - M 6
RDRK 60 60 21–400–024–1 0 21–400–024–K1 0 5,00 21,00 290 200 240 190 120 85 M 10
Subject to technical modifications Standard stock items
D 1/2
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 3

Three-phase
compact rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRKL 10 – 120

Standard version: with connected three-phase bridge rectifier,


input 3 x 380/400/420 V, output 24 VDC, residual ripple < 5%
Capacitor version: with connected three-phase bridge rectifier and capacitor
input 3 x 380/400/420 V, output 24 VDC, residual ripple < 2%
Series RDRKL, just like RDRK, has been developed specially for application in pro-
grammable logic controllers (PLC). The transformers are well dimensioned and vol-
tage stable allowing for particular flat characteristic between no-load and load.
Over- or undervoltages, critical for PLC's, do not occur even at increased mains vol-
tage fluctuations.
Series RDRKL is equipped with strongly oversized profile heat sinks that guarantee
intensified heat dissipation. Its rectifiers are protected against temporary current
surges and voltage spikes.
The capacitor version is protected via a mini circuit board containing a matching va-
ristor, foil capacitor and discharge resistor.
Harmonic rule EN 61000-3-2 is observed.

Power packs
Design: Open horizontal design, stationary, for installation and set-up in dry rooms, separate
windings, sturdy mounting brackets. All connections to non-tracking terminal
blocks with screw connections. The terminals are protected against finger touch or
contact with the back of the hand in compliance to accident prevention regulations
(VBG 4).
IP 00, suitable for installation up to protection rating IP 23, insulation class E, max.
ambient temperature ta40°C, color grey, heat sink black anodized.
Capacitor versions show a slight diversion from stated measurements but attach-
ments remain the same.
Further designs available on request (fuses, voltages, connections, etc.)

3x 380/400/420 V 3x 380/400/420 V Copper Total


Model Current 24 VDC 24 VDC weight weight Approx. dimensions in mm
without capacitor with capacitor
A DC Article-no. Article-no. kg kg a b c d e Attachment
RDRKL 1 0 10 22–400–024–0 1 22–400–024–K0 1 1 ,4 6,0 156 165 160 140 100 M5
RDRKL 1 6 16 22–400–024–02 22–400–024–K02 2,5 8,6 206 200 190 184 120 M6
RDRKL 20 20 22–400–024–03 22–400–024–K03 2,8 10,4 206 200 200 184 120 M6
RDRKL 25 25 22–400–024–04 22–400–024–K04 3,0 10,8 206 200 200 184 120 M6
RDRKL 30 30 22–400–024–05 22–400–024–K05 4,0 1 1 ,0 206 220 200 184 120 M6
RDRKL 40 40 22–400–024–06 22–400–024–K06 5,8 22,0 254 240 230 228 152 M6
RDRKL 60 60 22–400–024–07 22–400–024–K07 6,6 25,0 290 260 230 258 160 M8
RDRKL 90 90 22–400–024–08 22–400–024–K08 10,5 38,0 300 300 240 258 176 M8
RDRKL 120 120 22–400–024–09 22–400–024–K09 13,5 43,0 380 325 240 298 200 M8

Standard stock items Subject to technical modifications

D 1/3
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 4

Three-phase-universal-
compact-rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRKU 5 – 25

with connected three-phase bridge rectifier and capacitor


Interchangeable input connections:
3 x 210/220/230/240/255/265/275/290/300/
360/380/400/420/440/460/480/500/520 V
Output 24 V DC, residual ripple < 2%.
Design: Open design, stationary, for installation and set-p in dry rooms, separate win-
dings, sturdy mounting brackets. Connection to non-tracking transformer ter-
minals with screw- and tab connection 2.8 x 0.8 mm up to 5 A, and 6.3 x 0.8
mm up to 20 A. According to DIN 46249, the tab connection 2.8 x 0.8 mm can
only be loaded up to 5 A, and the 6.3 x 0.8 up to 20 A. The terminals are protec-
ted against finger touch or contact with the back of the hand in compliance to
accident prevention regulations (VBG 4).
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C.
Power packs

Harmonic rule EN 61000-3-2 is observed.

3x 210–520 V Copper Total


Model Current Size 24 VDC weight weight Approx. dimensions in mm

A DC Article-no. kg kg a b c d e Attachment
RDRKU 5 5 3 UI 75/26 22–400–U–0 1 1 ,5 4,9 200 90 195 130 57 M6
RDRKU 1 0 10 3 UI 75/41 22–400–U–02 2,0 7,0 200 115 195 130 72 M6
RDRKU 1 5 15 3 UI 90/41 22–400–U–03 3,0 8,0 230 175 195 170 68 M6
RDRKU 20 20 3 UI 90/51 22–400–U–04 3,5 11,5 230 195 195 170 78 M6
RDRKU 25 25 3 UI 90/51 22–400–U–05 4,0 12,0 230 195 195 170 78 M6

Subject to technical modifications Standard stock items


D 1/4
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 5

Three-phase
compact rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRKN 10 – 60

Standard version: with connected three-phase bridge rectifier


input 3x 380/400/420 V, output 24 VDC, residual ripple < 5 %
Capacitor version: with connected three-phase bridge rectifier and capacitor
input 3x 380/400/420 V, output 24 VDC, residual ripple < 2 %
Design: Closed design, stationary, for installation and set-up in dry rooms, separate
windings, sturdy mounting brackets. Connection to non-tracking transformer
terminals with screw connection. The terminals are protected against finger
touch or contact with the back of the hand in compliance to accident preven-
tion regulations (VBG 4).
Harmonic rule EN 61000-3-2 is observed.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C.
Merits: Core loss reduction by two-way lamination, safeguarded against short cut via
insulated bushings, low voltage drop (no-load - load operation), low total los-
ses, temperature reserves - full load capacity even at ta 60°C/E, high output at

Power packs
short-time duty, mounting brackets comp. to DIN 41307, attachment dimen-
sions comp. to DIN 41308.

Standard version:
3⳯380/400/420 V Copper Total
Model Current Approx. dimensions in mm
24 V DC weight weight
ADC Article-no. kg kg a b c d e Attachment
RDRKN 1 0 10 28–400–024–0 1 1,6 4,9 156 165 110 140 100 M5
RDRKN 1 6 16 28–400–024–02 1,9 6,5 156 165 125 140 100 M5
RDRKN 20 20 28–400–024–03 2,4 9,8 206 190 140 184 120 M6
RDRKN 25 25 28–400–024–04 3,2 10,7 206 200 160 184 120 M6
RDRKN 30 30 28–400–024–05 3,9 1 1 ,5 206 200 160 184 120 M6
RDRKN 40 40 28–400–024–06 6,0 17,0 254 235 155 228 152 M6
RDRKN 60 60 28–400–024–07 6,9 22,0 254 235 180 228 152 M6

Capacitor version:
3⳯380/400/420 V Copper Total
Model Current Approx. dimensions in mm
24 V DC weight weight
ADC Article-no. kg kg a b c d e Attachment
RDRKN 1 0 K 10 28–400–024–K 0 1 1,6 4,9 156 165 110 140 100 M5
RDRKN 1 6 K 16 28–400–024–K 02 1,9 6,5 156 165 125 140 100 M5
RDRKN 20 K 20 28–400–024–K 03 2,4 9,8 206 190 140 184 120 M6
RDRKN 25 K 25 28–400–024–K 04 3,2 10,7 206 200 160 184 120 M6
RDRKN 30 K 30 28–400–024–K 05 3,9 1 1 ,5 206 200 160 184 120 M6
RDRKN 40 K 40 28–400–024–K 06 6,0 17,0 254 235 155 228 152 M6
RDRKN 60 K 60 28–400–024–K 07 6,9 22,0 254 235 180 228 152 M6

Standard stock items (K) - capacitor version Subject to technical modifications

D 1/5
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 6

Three-phase
compact rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRKS 7,5 – 30

Circuit diagram standard version:

Circuit diagram capacitor version:


Power packs

Top view and terminal assignment:

Fuses: Current Fusing Current Fusing


Model input ␩
input output output
A A A A %
RDRKS 7,5 0,36 LS C 1 7,5 7,5 76,0
RDRKS 1 0 0,47 LS C 1 10,0 1 0 ,0 77,4
RDRKS 1 5 0,70 LS C2 15,0 1 5 ,0 76,6
RDRKS 20 0,94 LS C4 20,0 20,0 77,4
RDRKS 30 1,35 LS C6 30,0 30,0 80,9

Weights and order nos.: Copper Total 3 x 380/400/420V 3 x 380/400/420V


Model weight weight Losses 24VDC 24VDC
without capacitor with capacitor
kg kg W Article no. Article no.
RDRKS 7,5 (K) 1,2 3,8 57 0256-400-24-01 0257-400-24-K01
RDRKS 1 0 (K) 1,6 4,4 70 0256-400-24-02 0257-400-24-K02
RDRKS 1 5 (K) 1,8 6,3 110 0256-400-24-03 0257-400-24-K03
RDRKS 20 (K) 2,4 9,0 140 0256-400-24-04 0257-400-24-K04
RDRKS 30 (K) 3,9 11,5 170 0256-400-24-05 0257-400-24-K05

Subject to technical modifications (K)-capacitor version Standard stock items


D 1/6
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 7

Three-phase
compact rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRKS 7,5 – 30

In general: Series RDRKS in modern industrial design, meets national, international and
upcoming regulations. It was designed bearing following aspects in mind:

- optimal layout to reduce surface area


- simple mounting via open-ended slot
- compact construction and low weight
- high reliability and long service life
- good value for reasonable price
- low total losses

Design: Covered, stationary, for installation and set-up in dry rooms, separate win-
dings, open-ended mounting slot integrated in cover. Connection to non-
tracking transformer terminals with screw connection. Terminals are protected
against finger touch or contact with the back of the hand in compliance to acci-

Power packs
dent prevention regulations (VBG 4).

Technical data: Input: 3 x 380/400/420 V


Output: 24 VDC with connected three-phase bridge rectifier, varistor,
resistor, LED, universal blade fuse, residual ripple < 5% or
24 VDC with connected three-phase bridge rectifier, varistor,
resistor, LED, universal blade fuse, electrolyte capacitor, resi-
dual ripple < 2% (capacitor version).
Harmonic rule EN 61000-3-2 is observed.
Test voltage: between input and output circuit 4467V, 50 Hz
Design: IP 00, suitable for installation up to protection rating IP 23,
insulation class E, max. ambient temperature ta 40°C
Other voltages available on request.

Standard version:
3 x 380/400/420 V 3 x 380/400/420 V
Model Current Approx. dimensions in mm
24 V DC 24 V DC
ADC Article no. Article no. (K) a b c d e f Attachment
RDRKS 7,5 (K) 7,5 0256-400-24-0 1 0257-400-24-K01 125 105 200 90 90 165 M5
RDRKS 10 (K) 10 0256-400-24-02 0257-400-24-K02 125 105 200 90 90 165 M5
RDRKS 15 (K) 15 0256-400-24-03 0257-400-24-K03 125 130 200 90 115 165 M5
RDRKS 20 (K) 20 0256-400-24-04 0257-400-24-K04 190 130 200 150 115 165 M6
RDRKS 30 (K) 30 0256-400-24-05 0257-400-24-K05 190 165 200 150 135 165 M6

Standard stock items (K) - capacitor version Subject to technical modifications

D 1/7
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 8

Three-phase
compact rectifier transformers
Safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
RDRKG 5 – 60

Irrespective of operation mode, series RDRKG remains well below the limit va-
lues for rated voltage 24 V DC, laid down in EN61131-2 / part 2 (D.C. power
supplies for electronic control units). It even applies for mains fluctuations of
+ 10% / -10% acc. to DIN IEC 38. Generously dimensioned electrolytic capaci-
tors achieve a minimal residual ripple of ≤ 2% required for exacting demands.
Consumers are comprehensively protected against interference voltage spi-
kes, overvoltage, HF interference voltages and capacitor residual charges. All
models of series RDRKG are manufactured with high performance ICs in hy-
brid technology on aluminum-oxide ceramic-basis and are fused on output si-
de.
Harmonic rule EN 61000-3-2 is observed.
Units RDRKG 5 - 10 are protected by quick safety fuses and from 16 A upwards
with high-performance automatic circuit breakers comp. to VDE 0660 Part 104
featuring thermal release for overload protection and electromagnetic instant-
aneous trip for short-circuits.
The compact power packs of series RDRKG base on transformers comp. VDE
Power packs

0570. They meet the requirements for protection against electric shock comp.
to DIN VDE 0106 Part 101.
The safe separation of protection low voltage (SELV)- and functional low volta-
ge (FELV)- circuits from other circuits is thereby ensured.
Developed for "worst case"-conditions, these units are way above rating and
can be operated in any position at ta 60°C.
The sensitive parts are encased in well-ventilated housings.
Design: Closed design, stationary, for installation and set-up in dry rooms, separate
windings, sturdy mounting brackets. Connections to non-tracking terminal
blocks with screw connections. The terminals are protected against finger
touch or contact with the back of the hand in compliance to accident preven-
tion regulations (VBG 4).
Input 3 x 380/400/420 V
Output 24 VDC, residual ripple < 2%
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 60°C.

3x 380/400/420 V Copper Total


Model Current Approx. dimensions in mm
24 V DC weight weight

A DC Article-no. kg kg a b c d1 d e Befestigung
RDRKG 5 5 21–400–024–G 2 0,80 3,30 145 85 157 135 90 50 M5
RDRKG 7,5 7,5 21–400–024–G 3 1 ,20 4,50 180 105 190 170 113 50 M5
RDRKG 1 0 10 21–400–024–G 4 1 ,40 5,50 180 105 190 170 113 64 M5
RDRKG 1 6 16 21–400–024–G 5 2,50 7,80 200 200 175 185 134 166 M6
RDRKG 20 20 21–400–024–G 6 2,80 1 1 ,30 200 210 175 185 134 176 M6
RDRKG 25 25 21–400–024–G 7 3,00 1 1 ,80 200 210 175 185 134 176 M6
RDRKG 30 30 21–400–024–G 8 4,00 14,00 200 210 175 185 134 176 M6
RDRKG 40 40 21–400–024–G 9 5,80 23,00 285 220 220 260 185 195 M8
RDRKG 60 60 21–400–024–G 10 6,60 25,00 285 234 220 260 185 210 M8
Subject to technical modifications Standard stock items
D 1/8
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 9

Three-phase switch power packs, secondary switched


Three-phase safety transformers comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
RSNT 20 – 60 G regulated
The switch power packs of series RSNT 20–60 G are assembled with three-phase isolating transformers and subsequent
switching controllers. They remain well below the permissible interference levels defined in VDE 0875 Part 11, EN 55011
limit curve B.
The patented switching concept ensures an extremely low interference level. There is no need for filtering or shielding
whatsoever.
The switch power packs are overload and short circuit proof and can be connected in parallel without restriction. An inter-
nal electronic fuse ensures that units are always operated within safe operating range (SOA protection).
Two LEDs indicate momentary operation mode, green for constant voltage and yellow for constant current mode.
Design: Robust steel housing with integrated mounting holes, for installation and set-up in dry rooms. Primary, secondary
and ground connection via protruded, non-tracking terminal blocks with screw connections. The terminals are protected
against finger touch or contact with the back of the hand in compliance to accident prevention regulations (VBG 4).

Power packs
Technical data RSNT 20G RSNT 30G RSNT 40G RSNT 50G RSNT 60G
Input
Mains input voltage 3 x AC 400 V
Mains input voltage range + 15 % to – 15 %
Frequency 50 Hz/60 Hz
Input current 1,3 A 2,0 A 2,6 A 3,2 A 3,7 A
Input fuses external (thermal-magnetic overload release)
Output
Output voltage DC 24 V stabilized, twin terminals, externally adjustable 0... DC30 V
Status display LED green / yellow (U / I)
Ready signal (terminal B) DC 24V / max. load DC 0.1A when unit is in constant voltage mode
Adjustable output current 0...20 A 0...30 A 0...40 A 0...50 A 0...60 A
Residual ripple < 30 mV RMS
Short-circuit protection constant current operation
Load stabilization dynamic < 100 mVss / 500µs.
Stability under constant conditions < 0,05 %
Mains stabilization < 0,05 %
Overtemperature protection thermal switch-off when overtemperature > 85°C
RFI suppression VDE 0875 / EN 55011
Ambient temperature -10... +40°C
General data
Test voltage transformer between input and output circuit comp. to regulations (safety transformer)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE mark yes
Installation orientation vertical
Cooling convection forced air
Type of connection screw-type terminal, finger-safe comp. to VBG4
2 2
Connection data fine strand, max. 4 / 10 mm fine strand, max. 4 / 16 mm
Mounting mounting brackets with keyhole attachment
Protection rating comp. DIN 0470 / EN 60529 IP 20
Safety class comp. IEC 536 / VDE 0106 part 1 I
Insulation class E
Dimensions in mm approx. (axbxc) 250 x 202 x 200 300 x 220 x 222 330 x 250 x 237
Mounting template in mm approx. (dxe) 228 x 161 278 x 179 308 x 209
Article no. 24-400-SNT-01-G 24-400-SNT-02-G 24-400-SNT-03-G 24-400-SNT-04-G 24-400-SNT-05-G
Copper weight in kg 3,4 3,8 5,8 8,5 8,5
Total weight in kg 13,0 21,0 22,5 25,0 26,5
Options
Remote control 0 - 10V for U / I
Remote control 4mA - 20mA for U / I
Switch-off input to take unit out of service connect terminal with 0V
Zero potential contact for centralized alarm for trouble (overtemperature, undervoltage and overload)

Standard stock items Subject to technical modifications

D 1/9
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 10

Primary switched three-phase switch power packs


RPL 2420 D and 2440 D comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
application as D.C./D.C.-converter possible

RPL 2420 D RPL 2440 D

Features: - application as power pack, battery charger or D.C./D.C.-converter


- output voltage 24 VDC, adjustable over a wide range
Power packs

- connection in parallel or series


- high efficiency
- input 3 x 400 VAC
- PFC comp. to EN 61000-3-2
- compact and robust construction in metal housing
- easy installation on DIN mounting rail, alternatively screw fastening
- safety class I
- noise transmission EN 50081-1, EN 55011 class B (industry),
EN 55022 class B (Telecom)
- noise immunity EN 50082-2: ESD, electromagnetic irradiation, burst, conducted
interference immunity, mains voltage dips
- overcurrent limiter and short-circuit proofing
- overtemperature protection
- inrush current limiter, enabling the use of conventional thermo-magnetic circuit
breakers with B- characteristic
- overvoltage limiter
- electronic overvoltage limiter
- status display: LED
- ambient temperature 0°C...+ 55°C without power reduction
- optional -25°C... +55°C

Power packs:
Model Output voltage Output current Article no.
rated voltage (VDC) setting range (VDC) ADC
RPL 2420 D 24 23... 29 20,0 0505-0002420D
RPL 2440 D 24 23... 28 40,0 0505-0002440D

Developments in process:
- units with higher performance up to app. 1500 W with three-phase supply
- units with multiple output voltages

Subject to technical modifications Standard stock items


D 1/10
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 11

Primary switched three-phase switch power packs


RPL 2420 D and 2440 D comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
application as D.C./D.C.-converter possible
Technical data 480W 960W
Model RPL 2420 D RPL 2440 D
INPUT
Rated input voltage, U1 rated AC 3 x 400V AC 3 x 400V
Voltage range, U1min - U1max AC 340-460V or DC 450V-740V AC 340-460V or DC 450V-740V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 550V varistor AC 550V
Rated current typical, I1 rated 1,1A at 400VAC 1,9A at 400VAC
Maximum transient pulse Ta=25°C < 26A at 400VAC < 18A at 400VAC
Maximum transient pulse Ta=55°C < 71A at 400VAC < 52A at 400VAC
Internal fuse - -
Recommended external fuse power circuit breaker B10, B16 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 20ms at 400VAC > 20ms at 400VAC
Reverse polarity protection D.C.-input yes yes
OUTPUT
Rated voltage U2 rated D.C 24V 24V
Voltage range U2 min - U2 max D.C. adjustable 23-29V adjustable 23-28V
Rated current I2 (at U2 rated) 20.0A 40.0A

Power packs
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical 20.5A 40.5A
Short circuit current typical < 22A < 45A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 60mV RMS < 60mV RMS
Mains stabilization U1min - U1max < 0,05 % < 0,05 %
Load stabilization load alteration < 0,25% < 0,25%
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0,02% / K < 0,02% / K
Operation in parallel and series yes yes
Status reports LED green LED green
Noise output zero potential change-over contact optional optional
Temperature compensation (battery charger) optional optional
external NTC-resistor
DIRECTIVES
Mains harmonics limit EN 61000-3-2 yes yes
Noise transmission EN 550081-1, EN 55011 class B, EN 550081-1, EN 55011 class B,
EN 55022 class B EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test voltage input/housing 3750VAC RMS 50Hz, 1min 3750VAC RMS 50Hz, 1min
Test voltage input/output 3750VAC RMS 50Hz, 1min 3750VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 92% at 400VAC and 100%-load > 94% at 400VAC and 100%-load
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature 0 up to +55°C 0 up to +55°C
Storage temperature -24°C up to +85°C -24°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
4-pole 0,75-2,5mm2 (L1/L2/L3/PE) 4-pole 0,75-2,5mm2 (L1/L2/L3/PE)
for D.C./D.C.-converter: + on L1, - on L2 for D.C./D.C.-converter: + on L1, - on L2
Connection output voltage connector RM7,62mm to screw print terminal RM10, 16mm to screw
4-pole 0,75-4,0mm2 (+ + - -) 4-pole 0,75-10,0mm2 (+ + - -)
Connection noise output and optional optional
temperature compensation
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation front plate horizontal, connections below front plate horizontal, connections below
Approx. dimensions in mm (W x H x D) 245 x 138 x 100 mm ca. 285 x 174 x 110 (mm)
Approx. total weight 2,2kg ca. 3,3kg
Standard stock items Subject to technical modifications

D 1/11
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 12

D 1/12
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 13

Three-phase IU battery chargers


RLSN 1220 – 2460 comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)

The IU charging method combined with our patented switching concept is particularly efficient for lead acid batteries
because it is best adapted to their charging characteristic.
The service life of maintenance-free lead acid batteries increases considerably by this gentle charging method. Two
LEDs indicate operation modes. Buffer-battery operation is fully guaranteed.
Battery chargers series RLSN are enclosed in a plastic coated steel housing providing comprehensive protection
against accidental contact. The battery chargers in modern industrial design fulfill safety requirements for protection
against electric shock comp. to VDE 0106 part 101.

Battery chargers
RLSN 2420 RLSN 2440 RLSN 2460

Technical data for model RLSN 1220 RLSN 2420 RLSN 1240 RLSN 2440 RLSN 1260 RLSN 2460
Input
Mains input voltage AC 3x 400V
Mains input voltage range + 15 % to - 15 %
Frequency 50Hz / 60Hz
Input fuses external (thermal/magnetic overload release)
Input current 1,3 A 1,3 A 2,6 A 2,6 A 3,7 A 3,7 A
Output
Battery rated voltage DC 12 V DC 24 V DC 12 V DC 24 V DC 12 V DC 24 V
Max. charge current DC 20A DC 20A DC 40A DC 40A DC 60A DC 60A
Battery type all types of lead acid batteries
Status display yellow constant current mode
LEDs green constant voltage mode
Residual ripple of charge current < 0,5%
Charging characteristic IU
Overload protection internal electronic current limiter
Reverse current when mains off, I =< 30mA
Overtemperature protection automatic cut-off with reset at overtemperature
RFI suppression better than VDE 0871, limit curve B / EN 55 011
Temperature range -10° C to + 40° C
Efficiency >90%
General data
Transformer test voltage between input and output comp. to regulation (safety transformers)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE mark yes
Installation orientation cooling fins vertical
Cooling convection Zwangskühlung
Type of connection terminal blocks (protected against finger touch comp. UVV (VBG 4)
Connection data fine strand fine strand fine strand
primary max. 4 mm2 primary max. 4 mm2 primary max. 4 mm2
2
secondary max. 10 mm secondary max. 10 mm2 secondary max. 16 mm2
Mounting integrated mounting brackets with keyhole attachment
Protection rating (VDE 0470 / EN 60529) IP 20
Safety class I
Insulation class E
Dimensions in mm approx.
(Length/Width/Height) 250 / 202 / 200 300 / 220 / 222 330 / 250 / 237
Mounting template in mm approx. 228 / 161 278 / 179 308 / 209
Article no. 0234-400-012-01 0233-400-024-01 0234-400-012-02 0233-400-024-02 0234-400-012-03 0233-400-024-03
Copper-weight in kg 3,4 5,8 8,5
Weight in kg 13,0 22,5 26,5
Subject to technical modifications Standard stock items
D 1/13
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 14

Primary switched three-phase battery chargers


RPL 2420 DL and 2440 DL comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
application as D.C./D.C.-converter possible

RPL 2420 DL RPL 2440 DL

Features: - application as power pack, battery charger or D.C./D.C.-converter


- output voltage 24 VDC, adjustable over a wide range
- connection in parallel or series
- high efficiency
- input 3 x 400 VAC
- PFC comp. to EN 61000-3-2
- compact and robust construction in metal housing
- easy installation on DIN mounting rail, alternatively screw fastening
Battery chargers

- safety class I
- noise transmission EN 50081-1, EN 55011 class B (industry),
EN 55022 class B (Telecom)
- interference immunity EN 50082-2: ESD, electromagnetic irradiation, burst, con-
ducted interference immunity, mains voltage dips
- overcurrent limiter and short-circuit proofing
- overtemperature protection
- inrush current limiter, enabling the use of conventional thermo-magnetic circuit
breakers with B- characteristic
- overvoltage limiter
- electronic overvoltage limiter
- status display: LED
- ambient temperature 0°C...+ 55°C without power reduction
- optional -25°C... +55°C

Battery chargers:
Model Output voltage Output current Article no.
rated voltage (VDC) setting range (VDC) ADC
RPL 2420 DL 27,4 23... 29 20,0 0525-002420DL
RPL 2440 DL 27,4 23... 28 40,0 0525-002440DL

Developments in process:
- units with higher performance up to app. 1500 W with three-phase supply
- units with multiple output voltages

Subject to technical modifications Standard stock items


D 1/14
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 15

Primary switched three-phase battery chargers


RPL 2420 DL and 2440 DL comp. VDE 0570 part 2-17, EN 61558-2-17, EN 60950 class 1
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)
regulated
application as D.C./D.C.-converter possible
Technical data 480W 960W
Model RPL 2420 DL RPL 2440 DL
INPUT
Rated input voltage, U1 rated AC 3 x 400V AC 3 x 400V
Voltage range, U1min-U1max AC 340-460V or DC 450V-740V AC 340-460V or DC 450V-740V
Frequency 45-65 Hz 45-65 Hz
Overvoltage protection varistor AC 550V varistor AC 550V
Rated current typical, I1 rated 1,1A at 400VAC 1,9A at 400VAC
Maximum transient pulse Ta=25°C < 26A at 400VAC < 18A at 400VAC
Maximum transient pulse Ta=55°C < 71A at 400VAC < 52A at 400VAC
Internal fuse - -
Recommended external fuse power circuit breaker B10, B16 power circuit breaker B10, B16
Maximum switching rate 30 switching cycles per hour 30 switching cycles per hour
Bypass power-line failure > 20ms at 400VAC > 20ms at 400VAC
Reverse polarity protection D.C.-input yes yes
OUTPUT
Rated voltage U2 rated D.C. 27,4V 27,4V
Voltage range U2min - U2max D.C. adjustable 23-29 V adjustable 23-28 V
Rated current I2 (at U2 rated) 18.0A 38.0A
Protection overload, short circuit, no-load yes yes
Overcurrent limit typical 18.0A 38.5A
Short circuit current typical < 22A < 45A
Overvoltage protection yes yes
Residual ripple f=20Hz...300kHz, Ta=25°C < 60mV RMS < 60mV RMS
Mains stabilization U1min - U1max < 0,05 % < 0,05 %

Battery chargers
Load stabilization load alteration < 0,25% < 0,25%
10% <-> 90%
Overshoot/control time load leap < 3.0% < 3ms < 3.0% < 3ms
10% <-> 90%"
Temp. stability < 0,02% / K < 0,02% / K
Operation in parallel and series yes yes
Status reports LED green LED green
Noise output zero potential change-over contact optional optional
Temperature compensation (battery charger) optional optional
external NTC-resistor
DIRECTIVES
Mains harmonics limit EN 61000-3-2 yes yes
Noise transmission EN 550081-1, EN 55011 class B, EN 550081-1, EN 55011 class B,
EN 55022 class B EN 55022 class B
Interference immunity EN 50082-2 EN 50082-2
Safety EN 60950 class I EN 60950 class I
Test voltage input/housing 3750VAC RMS 50Hz, 1min 3750VAC RMS 50Hz, 1min
Test voltage input/output 3750VAC RMS 50Hz, 1min 3750VAC RMS 50Hz, 1min
Test voltage output/housing 500VDC 500VDC
Humidity 85% RH IEC 68-2-30 85% RH IEC 68-2-30
Vibration and shock ETS 300 019-2-4, class 4M5 ETS 300 019-2-4, class 4M5
CE mark yes yes
OPERATING DETAILS
Efficiency typical > 92% at 400VAC and 100%-load > 94% at 400VAC and 100%-load
Protection rating comp. VDE 0470 / EN 60529 IP 20 IP 20
Protection class comp. IEC 536, VDE 0106 T1 I I
Overtemperature protection yes yes
Ambient temperature 0 bis +55°C 0 bis +55°C
Storage temperature -24°C up to +85°C -24°C up to +85°C
Cooling free convection free convection
MECHANICS
Connection input voltage connector RM7,62mm to screw connector RM7,62mm to screw
4-pole 0,75-2,5mm2 (L1/L2/L3/PE) 4-pole 0,75-2,5mm2 (L1/L2/L3/PE)
for D.C./D.C.-converter: + on L1, - on L2 for D.C./D.C.-converter: + on L1, - on L2
Connection output voltage connector RM7,62mm to screw print terminal RM10, 16mm to screw
4-pole 0,75-4,0mm2 (+ + - -) 4-pole 0,75-10,0mm2 (+ + - -)
Connection noise output and optional optional
temperature compensation
Housing design aluminum / steel aluminum / steel
Mounting snap-on onto mounting rail snap-on onto mounting rail
DIN EN 50022 DIN EN 50022
Installation orientation front plate horizontal, connections below front plate horizontal, connections below
Approx. dimensions in mm (WxHxD) 245 x 138 x 100 mm ca. 285 x 174 x 110 (mm)
Approx. total weight 2,2kg ca. 3,3kg
Standard stock items Subject to technical modifications

D 1/15
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 16

D 1/16
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 17

Three-phase - UPS - modules


RSNT 20GU - RSNT 60GU
comp. VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)

Technical data RSNT 20GU RSNT 40GU RSNT 60GU


Input
Mains input voltage 3 x AC 400 V
Mains input voltage range + 15 % to – 15 %
Frequency 50 Hz/60 Hz
Input current 1,3 A 2,6 A 3,7 A
Input fuses external (thermal-magnetic overload release)
Output
Output voltage DC 24 V stabilized, twin terminals, externally adjustable 0... DC24 V

UPS
Status display LED green / yellow (U / I)
Zero potential contact centralized alarm for trouble (overtemperature, undervoltge and overload)
Switch off input to take unit out of service connect terminal with 0V
Indication UPS-mode break contact to 0V
Output current adjustable 0...20 A 0...40 A 0...60 A
Residual ripple < 30 mV RMS
Short-circuit proofing constant current operation
Load stabilization dynamic < 100 mVss / 500µs
Stability under constant conditions < 0,05 %
Mains stabilization < 0,05 %
Overtemperature protection thermal switch-off when overtemperature > 85°C
RFI suppression VDE 0875 / EN 55011
Ambient temperature -10... +40°C
General data
Test voltage transformer between input and output complying to regulation (safety transformer)
Directives VDE 0570 part 2-6, EN 61558-2-6, EN 61000-3-2, EN 61131-2/part 2
CE mark yes
Installation orientation vertical
Cooling convection forced air
Type of connection screw-type terminal, finger-safe comp. UVV (VBG4)
2 2
Connection data fine strand max. 4 / 10 mm fine strand max. 4 / 16 mm
Mounting mounting brackets with keyhole attachment
Protection rating comp. VDE 0470 / EN 60529 IP 20
Safety class comp. IEC 536, VDE 0106 T1 I
Insulation class E
Dimensions in mm approx. (axbxc) 250 x 202 x 200 300 x 220 x 222 330 x 250 x 237
Mounting template in mm approx (dxe) 228 x 161 278 x 179 308 x 209
Article no. 0255-000020GU 0255-000040GU 0255-000060GU
Copper weight in kg 3,4 5,8 8,5
Total weight in kg 13,0 22,5 26,5
Options
Remote control 0 - 10V for U / I
Remote control 4mA - 20mA for U / I

Subject to technical modifications Standard stock items


D 1/17
D_TEIL_041018.qxd 19.10.2004 10:33 Seite 18

Three-phase - UPS - modules


Power packs with UPS control function
RSNT 20GU to RSNT 60GU comp. to VDE 0570 part 2-6, EN 61558-2-6
Noise transmission EN 55011 class B (industry), EN 55022 class B (Telecom)

Product description

Standard switch power packs of series RSNT...G equipped with option U (UPS added) can be operated as control units
with mains identification. Combined with a lead acid or nickel-cadmium-battery of fitting size and capacity, the power
pack RSNT...GU can bridge the output voltage over a defined time period during mains voltage dips or breakdowns.
The possible time period depends solely on the battery's capacity. An undervoltage interruption is integrated for bat-
tery protection.
We recommend Riedel-chargers series RLG or RLEC for battery recharging.
For control of the RSNT...GU a terminal connection (OFF) is attached allowing power pack's switch off (connect termi-
nal to 0V). At mains breakdown an alarm contact (UPS) opens, i.e. information for processing can be taken from its ter-
minal. The contact is connected with 0V in closed condition (UPS-ready = open, UPS-run = 0V).

Without battery the unit can be applied as a normal power pack.

Functions: – full-automatic operation


– voltage adjustable 0-24VDC stabilized
– current adjustable 0-20/40/60ADC stabilized
– overtemperature protection
– switch off input (for shutdown RSNT...GU:
connect terminal "OFF" with 0V)
– switch off at under- and overvoltage
– indication constant current or constant voltage operation via LED
(LED green = CV, LED yellow = CC)
– indication UPS-operation via contact against ground (UPS-contact open)
– zero potential centralized alarm (trouble - contact is open)
activated when
- unit's operation temperature exceeds range
- undervoltage battery
UPS

- switch off input activated


- overload resp. short circuit

Block diagram:

24VDC
Power
consumer
RSNT..GU
UPS operation
OFF
F (trouble)

Battery
charger
RLG 27,6 DC
or
RLEC

Lead-acid battery 24V

Standard stock items Subject to technical modifications

D 1/18
E
Copyright: Lufthansa/Riedel Product group

Lufthansa has every right to be proud of its safe fleet. Extensive


maintenance carried out by highly qualified specialists using sophis-
ticated equipment establishes this pride and the worldwide confi-
dence in Lufthansa. Uncompromising quality and a strong endeavor
for absolute safety is our motto also. A good reason for the aircraft
industry to choose Riedel products.
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 2

Single-phase variable ratio ring transformers comp. VDE 0552/69

In general Installation and cooling


Our variable ratio ring transformers are manufactured Operation with rated power is possible up to ambient
comp. to VDE/EN/IEC-regulations. They are self cooling temperature 40°C maximal and an altitude up to 1000
via natural convection and designed for continuous m above sea level.
operation. Up to 2A rated current insulation class E ap-
In case of housing installment the internal temperature
plies, above that class B.
caused by self-heating of variable ratio ring transformer
and/or other heat-radiating parts must not exceed
Connection and fusing 40°C. If internal temperature exceeds 40°C either pro-
vide separate cooling via fan or reduce rated current by
Mains voltage should not permanently exceed stated 20 % each every 10 K temperature increase.
rated input voltage (see rating plate) by more than 6%
because the higher turn to turn voltage causes excessi-
ve warm-up of current collector's pad. Variable ratio Maintenance
ring transformers are designed for 50 - 60 Hz and may Maintenance is limited to soil removal on contact deck
be operated up to 400 Hz. We recommend safety fu- and testing whether current collectors run smoothly or
ses or overcurrent switches on output side for overload not.
or short circuit protection. In intervals of approx. 6 months - depending on opera-
Protectors on input side must be rated so that inrush tion conditions shorter or longer - variable ratio ring
current cannot trigger them. This inrush current - cau- transformers require following maintenance:
sed by the high quality core material (permeability) - Remove dust on contact deck with a brush or blow it
chiefly occurs with transformers in no-load condition off.
when switch-on takes place in voltage-zero passage. Contact deck may be wiped off with a spirit soaked
At small network impedance an inrush current of up to cloth. Black, blank traces on contact deck caused by
20 x (IN) can occur in concerned half-wave (10 ms at 50 contact roll are of no concern though. Any oxide layer
Hz). Even though this inrush current drops back to nor- developed through overlaod or aggressive atmosphe-
mal no-load current of transformer within a few periods, re must be removed with abrasive paper and also the
it will already trigger quick fuses. arisen abrasive dust must be removed. Carbon rolls
must not be non-circular and have to run smoothly
Therefore select slow-acting safety fuses or automatic when adjusting current collector. Stuck, non-circular or
circuit breakers (for apparatus protection). damaged carbon rolls must be exchanged.

Do not lubricate carbon roll suspensions!

Permissible overload during short-time duty in % of rated current


Repeat overload is permitted only after transformer windings have fully cooled down.
% above rated current

Ec Ec Iso
on on lat
om om ew
y y win ind
win din ing
din g,
g, siz
siz e1
e6 14
4- up
96 wa
rds

Seconds Minutes

Short-term delivery
E 1/2
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 3

Single-phase variable ratio ring transformers comp. VDE 0552/69


in economy circuit

RRSP 73 - 2912
Design: Open frame, stationary, for installation and set-up in dry rooms, economy circuit, connection to screw termi-
nals. General 3-spot-front attachment, size 65 - 95 central attachment
IP 00, suitable for installation up to protection rating IP 23, up to 2 A insulation class E, above that class B, max. ambient
temperature ta 40°C.
Design with isolate windings available on request

230V 230V 230V 400V


Model Current Current Current Current
0-230V -1% 0-260V +5% -1% 0-300V +5% -1% 0-400V -1%
A Article-no. A Article-no. A Article-no. A Article-no.
RRSP 65 1 ,00 26–230–230–01 0,50 26–230–260–01 – – – –
RRSP 75 1 ,25 26–230–230–02 0,80 26–230–260–02 – – – –
RRSP 85 2,00 26–230–230–03 1 ,00 26–230–260–03 – – – –
RRSP 94 2,50 26–230–230–04 1 ,60 26–230–260–04 1,00 26–230–300–04 0,80 26–400–400–04
RRSP 95 3,20 26–230–230–05 2,00 26–230–260–05 1,25 26–230–300–05 1,00 26–400–400–05
RRSP 114 4,00 26–230–230–06 2,00 26–230–260–06 1,60 26–230–300–06 1,60 26–400–400–06
RRSP 115 5,00 26–230–230–07 4,00 26–230–260–0 7 2,00 26–230–300–0 7 2,00 26–400–400–0 7
RRSP 116 6,30 26–230–230–08 5,00 26–230–260–08 2,50 26–230–300–08 2,50 26–400–400–08
RRSP 136 8,00 26–230–230–09 6,30 26–230–260–0 9 5,00 26–230–300–09 4,00 26–400–400–09
RRSP 137 10,00 26–230–230–10 8,00 26–230–260–1 0 – – 5,00 26–400–400–10
RRSP 157 12,50 26–230–230– 11 10,00 26–230–260–1 1 6,30 26–230–300–1 1 6,30 26–400–400–1 1
RRSP 178 16,00 26–230–230–12 12,50 26–230–260–12 8,00 26–230–300–12 8,00 26–400–400–12
RRSP 217 20,00 26–230–230–13 – – – – 10,00 26–400–400–13
RRSP 257 25,00 26–230–230–14 – – 12,50 26–230–300–14 12,50 26–400–400–14
RRSP 2570 32,00 26–230–230–15 – – – – – –
RRSP 2970 40,00 26–230–230–16 – – – – – –
RRSP 2512 50,00 26–230–230–17 40,00 26–230–260–17 – – 25,00 26–400–400–17
RRSP 2912 63,00 26–230–230–18 50,00 26–230–260–18 32,00 26–230–300–18 40,00 26–400–400–18
RRSP 3515 80,00 26–230–230–19 80,00 26–230–260–19 63,00 26–230–300–19 50,00 26–400–400–19

Model Copper weight Total weight Approx. dimensions in mm

app. kg app. kg D H B F d.
RRSP 65 0,040 1 ,20 74 75 26 M4 6
RRSP 75 0,070 1 ,50 86 75 26 M4 6
RRSP 85 0,1 20 2,00 96 76 26 M4 6
RRSP 94 0,1 60 2,20 106 68 26 M4 6
RRSP 95 0,250 2,60 106 78 26 M4 6
RRSP 114 0,300 3,30 131 90 80 M6 6
RRSP 115 0,370 4,00 131 105 80 M6 6
RRSP 116 0,450 4,70 131 115 80 M6 6
RRSP 136 0,900 6,20 148 120 110 M8 10
RRSP 137 1,000 7,30 148 130 110 M8 10
RRSP 157 1,200 9,30 170 130 110 M8 10
RRSP 178 1,600 13,00 190 150 110 M8 10
RRSP 217 2,1 50 16,00 230 155 150 M8 10
RRSP 257 3,1 50 19,00 270 155 150 M8 10
RRSP 2570 3,250 20,00 270 210 150 M8 10
RRSP 2970 4,500 26,00 315 225 150 M8 10
RRSP 2512 6,000 39,00 270 270 150 M8 10
RRSP 2912 8,000 46,00 315 280 150 M8 10
RRSP 3515 1 0,000 78,00 385 350 150 M 10 10

Short-term delivery Subject to technical modifications


E 1/3
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 4

Motor drives for single-phase variable ratio ring transformers

RSM 1 - RSM 14
Design: Single-phase synchronous motor 230 V, 50 Hz, unipolar reversible, incl. one limit switch each in both final posi-
tions and indexing disks with fine tuning.
Motor drives are available in different regulating times (6/12/30/60 sec.). Please state in order. Other regulating times
and servo drives with d.c. motors on request.

Drawing RSM 1-14:

Motor drive Weight without


for size Approx. dimensions in mm
Model transformer
Article-no. RRSP kg A B C D E F G
RSM 1 65-75 0,8 235 180 270 90 150 250 -
RSM 2 85 0,8 245 180 270 90 150 250 -
RSM 3 94-95 0,9 275 180 270 90 150 250 -
RSM 4 114-116 1,0 280 180 270 90 150 250 -
RSM 5 136-137 1,4 280 180 270 170 150 250 -
RSM 6 157 1,8 300 180 270 150 150 250 -
RSM 7 178 2,0 300 190 270 150 150 250 -
RSM 8 217 3,2 310 230 350 150 170 330 -
RSM 9 257 3,4 320 275 350 150 170 330 -
RSM 10 2570 12,0 465 375 500 225 250 475 60
RSM 11 2970 12,0 465 405 500 225 250 475 60
RSM 12 2512 15,0 535 375 500 225 250 475 60
RSM 13 2912 15,6 535 405 500 225 250 475 60
RSM 14 3515 16,5 580 465 555 370 300 525 60

* set regulating time as ordered

Subject to technical modifications


E 1/4
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 5

Three-phase variable ratio ring transformers comp. VDE 0552/69


in star-economy circuit

RDRSP 73 - 3515 (vertical design)


Design: Open frame, stationary, for installation and set-up in dry rooms, economizing circuit, connection to screw termi-
nals.
IP 00, suitable for installation up to protection rating IP 23, up to 2 A insulation class E, above that class B, max. ambient
temperature ta 40°C. Flat design available on request

Design “A” Design “B”

3 x 400 V 3 x 400 V
3 x 400 V
Model Current Current 3 x 0–450 V Current 3 x 0–520 V
3 x 0–400 V–1 % +5 %–1 % +5 %–1 %
3xA Article-no. 3xA Article-no. 3xA Article-no.
RDRSP 73 0,80 27–400–400–01 – – – –
RDRSP 74 1,00 27–400–400–02 – – – –
RDRSP 84 1,60 27–400–400–03 – – – –
RDRSP 94 2,50 27–400–400–04 – – 1,00 27–400–520–06
RDRSP 95 3,20 27–400–400–05 – – – –
RDRSP 114 3,20 27–400–400–06 – – – –
RDRSP 115 5,00 27–400–400–07 4,00 27–400–450–09 – –
RDRSP 116 6,30 27–400–400–08 5,00 27–400–450–10 – –
RDRSP 136 8,00 27–400–400–09 – – – –
RDRSP 137 10,00 27–400–400–10 – – – –
RDRSP 157 12,50 27–400–400– 11 10,00 27–400–450–13 – –
RDRSP 178 16,00 27–400–400–12 12,50 27–400–450–14 8,00 27–400–520–14
RDRSP 217 20,00 27–400–400–13 – – – –
RDRSP 257 25,00 27–400–400–14 – – 12,50 27–400–520–16
RDRSP 2570 32,00 27–400–400–15 – – – –
RDRSP 2970 40,00 27–400–400–16 – – – –
RDRSP 2512 50,00 27–400–400–17 – – – –
RDRSP 2912 63,00 27–400–400–18 50,00 27–400–450–17 32,00 27–400–520–17
RDRSP 3515 80,00 27–400–400–19 – – – –

Model Copper weight Total weight Approx. dimensions in mm

ca. kg ca. kg Design G H D/J M d


RDRSP 73 0,110 5,5 B 155 300 140 M 10 6
RDRSP 74 0,120 5,8 B 155 300 140 M 10 6
RDRSP 84 0,270 6,7 B 155 300 140 M 10 6
RDRSP 94 0,480 7,9 B 155 300 140 M 10 6
RDRSP 95 0,750 9,5 B 155 320 140 M 10 6
RDRSP 114 0,900 1 1 ,5 B 175 330 160 M 10 6
RDRSP 115 1,110 14,0 B 175 360 160 M 10 6
RDRSP 116 1,350 16,5 B 175 390 160 M 10 6
RDRSP 136 2,700 24,0 B 240 435 220 M 12 10
RDRSP 137 3,000 27,0 B 240 485 220 M 12 10
RDRSP 157 3,600 30,0 B 240 485 220 M 12 10
RDRSP 178 4,800 44,0 B 260 535 240 M 16 10
RDRSP 217 6,500 55,0 B 320 590 300 M 16 10
RDRSP 257 9,500 66,0 B 360 590 340 M 16 10
RDRSP 2570 9,800 70,0 B 440 670 420 M 16 10
RDRSP 2970 13,500 88,0 B 460 750 440 M 16 10
RDRSP 2512 18,000 135,0 A 380 970 297 M 20 10
RDRSP 2912 24,000 160,0 A 420 970 318 M 20 10
RDRSP 3515 30,000 250,0 A 475 1130 360 M 20 10

Subject to technical modifications


E 1/5
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 6

Motor drives for three-phase variable ratio ring transformers


Accessories and spare parts for variable ratio ring transformers (on request)

RSMD 1 - RSMD 19
Design: Single-phase synchronous motor 230V, 50 Hz, unipolar reversible, incl. one limit switch each in both final posi-
tions and indexing disks with fine tuning.
Motor drives are available in different regulating times (6/12/30/60 sec.). Please state in order. Other regulating times
and servo drives with d.c. motors on request.

Drawing: * set regulating time as ordered

Connection terminals

Weight without
Motor drive for transformer Approx. dimensions in mm
transformer
Article no. RDRSP kg G H D L M
RSMD 1 73 1,2 155 300 140 150 10
RSMD 2 74 1,2 155 300 140 150 10
RSMD 3 84 1,2 155 300 140 150 10
RSMD 4 94 1,2 155 300 140 150 10
RSMD 5 95 1,2 155 320 140 150 10
RSMD 6 114 1,2 175 330 160 150 10
RSMD 7 115 1,2 175 360 160 150 10
RSMD 8 116 1,2 175 390 160 150 10
RSMD 9 136 1,5 240 435 220 150 12
RSMD 10 137 1,5 240 470 220 150 12
RSMD 11 157 2,0 240 470 220 150 12
RSMD 12 178 2,0 260 535 240 150 16
RSMD 13 2 17 2,0 320 540 300 150 16
RSMD 14 257 2,0 360 590 340 150 16
RSMD 15 2570 2,0 440 695 420 210 16
RSMD 16 2970 2,0 460 750 440 210 16
RSMD 17 2512 2,0 380 970 297 200 20
RSMD 18 2912 2,0 420 970 318 200 20
RSMD 19 3515 4,0 475 1130 360 200 20

Rotating knobs
Model Approx. dimensions in mm
Article no. A B C D d
REK 30–40–6 38 28 12 41 6
REK 30–60–6 48 34 28 58 6
REK 30–60–10 48 34 28 58 10
REK 30–90–6 76 40 28 90 6
REK 30–90–10 76 40 28 90 10

Scales Material: aluminum, black anodized

Model Diameter
Labelling
Article no. mm

RES 31 – 60 – 100 60 0 – 100 %


RES 31 – 60 – 230 60 0 – 230 V
RES 31 – 90 – 100 92 0 – 100 %
RES 31 – 90 – 230 92 0 – 230 V
RES 31 –130 – 100 132 0 – 100 %
RES 31 –130 – 230 132 0 – 230 V

Subject to technical modifications


E 1/6
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 7

Voltage stabilizers comp. VDE 0552/69


Single-phase and three-phase

RSKH power range 1kVA and up


Riedel voltage stabilizers RSKH serve as series supply units in mains with fluctuating voltages. The voltage stabilizer's
exit generates constant voltage to the consumer independent from fluctuating mains.
Design: Riedel voltage stabilizers consist of a variable-ratio transformer with motor drive, a booster transformer and an
electronic controller. As soon as the controller detects any voltage deviation from set value at stabilizer's exit it activates
the variable-ratio transformer's motor and primary winding of booster transformer induces. This procedure causes the
secondary winding to add or subtract voltage from the mains and endures until secondary voltage reaches set value
again.
The controller functions as a proportional regulating amplifier featuring PI-performance and is located on a plug-in card,
which also contains the current supply part and actual value processing. Set-point adjustment for adaptation to dyna-
mic behavior of controlled process ensues via trimming resistor. The variable-ratio transformer's motor is controlled
contactless and control speed depends on mains voltage, i.e. high control rate at high deviation, small control rate at
minor deviation. The result is high-accuracy performance without control oscillations.
Technical data: Nominal input voltages: all typical mains up to 1 kV
Mains fluctuations: for example ±10%, ±15%, ±20%...
Mains frequency: 50/60 Hz or 400 Hz
Output accuracy: ±1%
Type of load: ohmic, inductive or capacitive
Efficiency: 98 - 99% depending on controller type
On-period: S1 operation (100%)
Protective system: IP 00

Chief applications: Machine controls EDV equipment


Test rooms and laboratories Medical electronics
Monitoring systems Telecommunication facilities
Process control Remote control
Air-traffic control Furnace heating

Available options: Protective system up to IP 65 max., tropic-proof, analog or digital meters, main switch and
fusing, galvanic isolation, maintenance service...

Basic circuit diagram: Three-phase mains with Three-phase mains with master control
individual phase control

1L1 2L1 1L1 2L1

M Control
Regler M Control
Regler

1L2 2L2 1L2 2L2

M Control
Regler

1L3 2L3 1L3 2L3

M Control
Regler

N N N N

Single-phase mains

1L1 2L1

M Control
Regler

N N

Manufacture according to customer specification Subject to technical modifications


E 1/7
E_TEIL_041018.qxd 19.10.2004 10:35 Seite 8
F
Copyright: Energieversorgung Schwaben AG/Riedel Product group

Environmental aspects cause utility companies to place the sun in


the zenith of their research. Solar energy costs decline making this
source a major contribution to CO2-free energy. However, pre-
requisite is highest efficiency – a good reason to choose Riedel
products.
F_TEIL_041018.qxd 19.10.2004 10:36 Seite 2

Choke coils Three-phase filter circuit chokes

Choke coils stand for inductors and in consequence re- Three-phase filter circuit chokes can be found in reacti-
active impedance. The energy created by the magnetic ve current compensation systems. Together with the
field of a current-carrying coil increases considerably system's capacitors they form a series resonant circuit
with high-permeability iron cores. thereby effecting in defined mains conditions. Choking
the reactive current compensating system prevents re-
Riedel – choke coils are designed as iron core chokes
sonance with occurring mains harmonics. Inductivities
with magnet gap.
of filter circuit chokes are selected with the imperative
Apart from a great variety of custom made products that resonant frequency of series resonant circuit for-
designed for specific applications we also offer a stan- med by capacitor and filter circuit choke lies below lo-
dard program comprising: west frequency of occurring harmonics.
Single-phase line chokes Increasing operation of converters and inverters cause
Series RENDr mains harmonics. Operation of 6-pulse bridge circuits
Rated voltage AC 230 V, voltage drop 4 % charge the mains with currents in ordinal numbers of
Single-phase double line chokes
Series RDNDr n = 6 x k +/-1 for k = 1, 2, 3,...
Rated voltage AC 400 V, voltage drop 2 x 2 %
Current amplitudes decrease with increasing ordinal
Three-phase filter circuit chokes number.
Series RFDr 7
Rated voltage 3AC 400 V, filter choke factor 7 % I(n) ~ n1 x l(1)
Three-phase line chokes
Series RNDr Choke factor p is the proportion of filter circuit choke re-
Rated voltage 3AC 400 V, voltage drop 4 % actance and capacitor reactance

p = XL
XC

Resonant frequency for series resonant circuit calculates

fR = fmains
⻫P
Line chokes
(Commutation chokes) When selecting a resonant frequency and thereby the
choke factor, consider the circular pilot frequency in the
respective net and coordinate its compatibility with the
Line chokes are necessary for current limiting and sup-
respective utility company.
pression of line reactions respectively commutation
notches. Dimensioning three-phase filter circuit chokes bases on
following premises:
Current IG is limited by the line choke and calculates
with formula Essential load:

I1 = -1,06 x Irated whereby Irated = Ncompensation


3x Urated
IG = IN x 100 %
Uk and N compensation is the effective compensating power of
choked capacitor configuration.
When connecting current converters to a.c. mains it al- Harmonic factor of mains voltage
ways necessitates mains inductivities in order to limit
commutation notches of line voltage. If the current con- U3 = 0,5 % U rated U 7 = 5 % Urated
verter is supplied via a converter transformer then the U5 = 5 % U rated U11 = 5 % Urated
transformer's control inductivity will take over the limita-
tion. According to requirements DIN VDE 0160, part 2, Thermal current
applying a current limiting power line choke is imperati-
Itherm = 1,05 x I12 + I32 + I52 + I72 + I112
ve at direct connection with or supply via an auto-trans-
former. Linearity
Ilin = 1,2 x (I1 + I3 + I5 + I7 + I11)
whereby inductivity amounts to at least 95 % of its rated
value.

F 1/2
F_TEIL_041018.qxd 19.10.2004 10:36 Seite 3

Single-phase line chokes


RENDr 1 – 32 comp. DIN VDE 0570 part 2-20

Line chokes are necessary for current limitation, suppression of line reactions
respectively commutation notches.
Current limitation preferably ensues on the 25-fold value of rated current. To
this end line chokes with 4% short circuit voltage must be used.
Line chokes are to be selected according to rated current of consumer.
Design: Open frame, stationary, for installation and set-up in dry rooms, sturdy moun-
ting brackets. Connection to non-tracking transformer terminals with screw-
and tab connection 2.8 x 0.8 mm up to 5 A and 6.3 x 0.8 mm up to 20A. Accor-
ding to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up to 5 A
and 6.3 x 0.8 up to 20 A. Above 20A terminal blocks with screw connections
are used. The terminals are protected against finger touch or contact with the
back of the hand in compliance to accident prevention regulations (VBG 4).
Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground
screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C
Technical data: Rated voltage: AC 230 V
Rated voltage drop (Uk): 4% (4,8% at 60 Hz)
Rated frequency: 50 Hz (60 Hz)
Line chokes with deviating technical data available on request.

Total Copper
Model Current Inductivity Article-no. Approx. dimensions in mm
weight weight
A mH kg kg a b c d e f Attachm.
RENDr 1 1,0 29,300 60–230–01 0,30 0,05 48 44 66 38 34 36 M3
RENDr 2 2,0 14,600 60–230–02 0,35 0,06 55 46 73 44 36 37 M3
RENDr 3 3,0 9,760 60–230–03 0,38 0,07 55 46 73 44 36 37 M3
RENDr 4 4,0 7,320 60–230–04 0,45 0,08 60 48 62 44 38 40 M3
RENDr 5 5,0 5,860 60–230–05 0,65 0,08 60 58 62 44 48 45 M3
RENDr 6 6,0 4,880 60–230–06 0,65 0,12 66 55 67 50 42 42 M4
RENDr 8 8,0 3,660 60–230–07 0,90 0,12 66 67 67 50 54 48 M4
RENDr 10 10,0 2,930 60–230–08 1,10 0,24 78 60 76 56 47 45 M4
RENDr 12,5 12,5 2,340 60–230–09 1,40 0,25 78 69 76 56 56 50 M4
RENDr 16 16,0 1,830 60–230–10 1,90 0,25 85 76 79 64 63 53 M4
RENDr 20 20,0 1,460 60–230–11 2,00 0,35 85 76 79 64 63 53 M4
RENDr 25 25,0 1,1 7 0 60–230–12 2,30 0,45 96 78 92 84 62 50 M5
RENDr 32 32,0 0,915 60–230–13 2,90 0,50 96 88 92 84 72 55 M5

delivery: on short notice Subject to technical modifications

F 1/3
F_TEIL_041018.qxd 19.10.2004 10:36 Seite 4

Single-phase twin-line chokes


RDNDr 2 – 32 comp. DIN VDE 0570 part 2-20

Double line chokes are necessary for current limitation, suppression of line
reactions respectively commutation notches. Thereby, through inductivity
partition onto both supply lines, symmetric connection of consumer ensues.
On each winding part about half the voltage drop develops. Series and paral-
lel connection of winding offer further applications up to double rated current
and half a voltage drop.
Current limitation preferably ensues on the 25-fold value of rated current. To
this end line chokes with 4% (2 x 2 %) short circuit voltage must be used.
Double line chokes are to be selected according to rated current of consu-
mer.
Design: Open frame, stationary, for installation and set-up in dry rooms, sturdy moun-
ting brackets. Connection to non-tracking transformer terminals with screw-
and tab connection 2.8 x 0.8 mm up to 5 A and 6.3 x 0.8 mm up to 20A.
According to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up
to 5 A and 6.3 x 0.8 up to 20 A. Above 20A terminal blocks with screw con-
nections or cable lugs are used. The terminals are protected against finger
touch or contact with the back of the hand complying to accident prevention
regulations (VBG 4).
Winding consists of 2 equivalent winding parts that are insulated against each
other.
Ground connection via tab blade connection 6.3 x 0.8 mm. Accessory ground
screw connection terminal available.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C.
Technical data: Rated voltage: AC 400 V
Rated voltage drop (Uk): 2 x 2 % (2 x 2,4 % at 60 Hz)
(series connection of winding parts: 4 %)
(parallel connection of winding parts: 1 %)
Rated frequency: 50 Hz (60 Hz)
Double line chokes with deviating technical data available on request.

Total Copper
Model Current Inductivity Article-no. Approx. dimensions in mm
weight weight
A mH kg kg a b c d e f Attachm.
RDNDr 2 2,0 2 x 12,700 61–400–01 0,45 0,07 60 48 62 44 38 40 M3
RDNDr 3 3,0 2 x 8,490 61–400–02 0,65 0,08 60 58 62 44 48 45 M3
RDNDr 4 4,0 2 x 6,370 61–400–03 0,85 0,08 66 67 67 50 54 48 M4
RDNDr 5 5,0 2 x 5,090 61–400–04 0,90 0,12 66 67 67 50 54 48 M4
RDNDr 6 6,0 2 x 4,240 61–400–05 1,10 0,24 78 60 76 56 47 45 M4
RDNDr 8 8,0 2 x 3,180 61–400–06 1,40 0,25 78 69 76 56 56 50 M4
RDNDr 10 10,0 2 x 2,550 61–400–07 1,90 0,25 85 76 79 64 63 53 M4
RDNDr 12,5 12,5 2 x 2,040 61–400–08 2,20 0,35 96 78 92 84 62 50 M5
RDNDr 16 16,0 2 x 1,590 61–400–09 2,80 0,40 96 88 92 84 72 55 M5
RDNDr 20 20,0 2 x 1,270 61–400–10 3,50 0,50 96 102 92 84 86 62 M5
RDNDr 25 25,0 2 x 1,020 61–400–11 3,60 0,70 105 86 110 84 70 52 M5
RDNDr 32 32,0 2 x 0,796 61–400–12 4,50 0,80 105 101 110 84 85 60 M5

Subject to technical modifications delivery: on short notice


F 1/4
F_TEIL_041018.qxd 19.10.2004 10:36 Seite 5

Three-phase filter circuit chokes


RFDr 7/2,5 – 7/50 comp. DIN VDE 0570 part 2-20 with matching power

Three-phase filter circuit chokes are necessary for reactive current compensa-
tion systems. Together with the system's capacitors they create a series reso-
nant circuit which results in defined mains conditions.
Three-phase filter circuit chokes with matching power interconnected with capa-
citors of stated capacity guarantee the designated compensating reactive power.
Three-phase filter circuit chokes lacking matching power are accessed accor-
ding to capacitors in use and lead to deviating compensating reactive power.
With frequently selected choking of 7% the series resonant circuit, formed by
filter circuit chokes and power factor capacitors, creates a resonant frequency
of 189 Hz.
Design: Open frame, stationary, for installation and set-up in dry rooms, sturdy mounting
brackets. Up to 12,5 kVAr connection to non-tracking transformer terminals
with screw- and tab connection 2.8 x 0.8 mm up to 5 A and 6.3 x 0.8 mm up to
20A. According to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded
up to 5 A and 6.3 x 0.8 up to 20 A. Above 12,5 kVAr up to 25 kVAr universal ter-
minal blocks with screw connections, 30 kVAr and above pressed cable lugs
are used. The terminals are protected against finger touch or contact with the
back of the hand complying to accident prevention regulations (VBG 4).
Temperature switch in center coil at hand.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C.
Technical data: Rated voltage. 3AC 400 V
Choking factor: 7%
Resonant frequency: 189 Hz
Rated frequency: 50 Hz
50 Hz current: 1 ,06 x rated current
1 50 Hz current: 0,04 x rated current
250 Hz current: 0,3 1 x rated current
350 Hz current: 0,13 x rated current

Filter circuit chokes with deviating technical data available on request.

Reactive Rated Total Copper


Model Inductivity Capacity Article-no. Approx. dimensions in mm
power current weight weight
kVAr mH ␮F A kg kg a b c d e f Attachm.
RFDr 7/2,5 2,5 15,34 46,3 3,6 62–407–01 2,0 0,8 125 73 115 100 45 45 M4
RFDr 7/5 5,0 7,67 92,5 7,2 62–407–02 5,0 0,9 155 92 140 130 72 50 M6
RFDr 7/7,5 7,5 5,1 1 138,8 10,8 62–407–04 5,3 1 ,2 155 92 140 130 72 50 M6
RFDr 7/10 10,0 3,84 185,0 14,4 62–407–05 9,0 1 ,8 190 102 165 170 78 65 M6
RFDr 7/12,5 12,5 3,07 231,3 18,0 62–407–06 9,5 2,6 190 102 165 170 78 65 M6
RFDr 7/15 15,0 2,56 277,5 21,7 62–407–07 10,5 3,5 190 102 210 170 78 55 M6
RFDr 7/17,5 1 7 ,5 2,1 9 323,8 25,3 62–407–08 15,0 3,5 210 117 230 175 97 60 M6
RFDr 7/20 20,0 1,92 370,0 28,9 62–407–09 16,0 4,5 210 117 230 175 97 60 M6
RFDr 7/25 25,0 1,53 462,5 36,1 62–407–10 19,0 4,8 230 148 240 180 122 80 M6
RFDr 7/30 30,0 1,28 555,1 43,3 62–407–11 20,5 6,5 230 148 205 180 122 120 M6
RFDr 7/40 40,0 0,96 740,1 57,7 62–407–13 28,0 10,0 240 146 215 190 120 130 M8
RFDr 7/50 50,0 0,77 925,1 72,2 62–407–1 4 33,0 10,5 265 152 235 215 126 140 M8

delivery: on short notice Subject to technical modifications

F 1/5
F_TEIL_041018.qxd 19.10.2004 10:36 Seite 6

Three-phase line chokes


RNDr 2,5 – 200 comp. DIN VDE 0570 part 2-20

Line chokes are necessary for current limitation, suppression of line reactions
respectively commutation notches.
Current limitation preferably ensues on the 25-fold value of rated current. To
this end line chokes with 4% short circuit voltage must be used.
Line chokes are to be selected according to rated current of consumer.
Design: Open frame, stationary, for installation and set-up in dry rooms, sturdy moun-
ting brackets. Connection to non-tracking transformer terminals with screw-
and tab connection 2.8 x 0.8 mm up to 5 A and 6.3 x 0.8 mm up to 20A. Accor-
ding to DIN 46249 tab connection 2.8 x 0.8 mm can only be loaded up to 5 A
and 6.3 x 0.8 up to 20 A. Above 20A terminal blocks with screw connections or
cable lugs are used. The terminals are protected against finger touch or con-
tact with the back of the hand complying to accident prevention regulations
(VBG 4).
Terminal connections above 60 A increase measurements b and c.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C
Technical data: Rated voltage: 3AC 400 V
Rated voltage drop (Uk): 4 % (4,8 % at 60 Hz)
Rated frequency: 50 Hz (60 Hz)
Line chokes with deviating technical data available on request.

Total Copper
Model Current Inductivity Article-no. Approx. dimensions in mm
weight weight
A mH kg kg a b c d e f Attachm.
RNDr 2,5 2,5 11,730 63–400–01 1,0 0,2 96 46 95 90 31 40 M4
RNDr 4 4,0 7,330 63–400–02 1,3 0,3 96 55 95 80 40 45 M4
RNDr 6 6,0 4,900 63–400–03 1,7 0,4 125 73 115 100 45 45 M4
RNDr 8 8,0 3,660 63–400–04 1,9 0,6 125 73 115 100 45 45 M4
RNDr 1 0 10,0 2,940 63–400–05 2,8 0,6 125 83 115 100 55 50 M4
RNDr 1 3 13,0 2,260 63–400–06 3,0 0,8 125 83 115 100 55 50 M4
RNDr 1 6 16,0 1,840 63–400–07 3,4 0,9 155 76 140 130 56 45 M6
RNDr 20 20,0 1,470 63–400–08 3,7 1,2 155 76 140 130 56 40 M6
RNDr 25 25,0 1 , 180 63–400–09 5, 1 1,2 155 91 140 130 71 46 M6
RNDr 30 30,0 0,980 63–400–1 0 5,4 1,5 155 91 140 130 71 46 M6
RNDr 40 40,0 0,740 63–400– 11 6,8 2,7 190 85 160 170 57 43 M6
RNDr 50 50,0 0,590 63–400–1 2 8,2 2,7 190 95 160 170 67 48 M6
RNDr 60 60,0 0,490 63–400–1 3 9,8 3, 1 190 105 160 170 77 53 M6
RNDr 80 80,0 0,370 63–400–1 4 13,0 3,5 210 117 180 175 97 59 M6
RNDr 90 90,0 0,330 63–400–1 5 14,0 4,0 240 121 210 190 95 61 M8
RNDr 100 100,0 0,290 63–400–1 6 16,0 4,3 240 131 210 190 105 66 M8
RNDr 120 120,0 0,250 63–400–17 18,0 5,9 240 131 210 190 105 66 M8
RNDr 140 140,0 0, 210 63–400–1 8 22,0 7,5 240 141 210 190 115 115 M8
RNDr 160 160,0 0,1 84 63–400–1 9 25,0 7, 7 240 151 210 190 125 120 M8
RNDr 180 180,0 0, 163 63–400–20 29,0 8,5 265 152 228 215 126 125 M8
RNDr 200 200,0 0, 147 63–400–21 30,0 10,0 265 152 228 215 126 135 M8

Subject to technical modifications delivery: on short notice


F 1/6
G
Copyright: Bundeswehr/Riedel Product group

The German Armed Forces establish safety. On the ground, in the


water and in the air the German Armed Forces strive for routine
handling of newest equipment. Manufacturers of such equipment
are bound by a great many safety directives and regulations. Un-
compromising quality safeguard and function control are a matter
of course – a good reason to choose Riedel products.
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 2

R-MED
Single-phase isolating transformers
RMED-E 3.15-8.0 comp. DIN VDE 0570 part 2-15, EN 61558-2-15

Design: Open frame, stationary, for installation and set-up in dry rooms, separate win-
dings, sturdy mounting brackets. Connection to non-tracking transformer ter-
minals with screw connection. The terminals are protected against finger touch
or contact with the back of the hand in compliance to accident prevention regu-
lations (VBG 4).
Necessary settings for display resp. report of warm-up and isolation monitoring
are protruded.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C. Other type of protection and manufacture
comp. to other norms available on request.

Terminal set-up and


wiring diagram:

PTC: PTC resistor


SW: screening foil

*RMED-E6.3 and above: terminals mounted on head angles

Rated pri: 230 V Copper Total


Model Power Approx. dimensions in mm
current sec: 230 V (115/0/115V) weight weight
single-phase kVA A Article-no. kg kg a b c d e Attachment
RMED-E 3.15 3,15 1 3,7 0211-RMed-E3.15 7,6 28,0 200 147 262 124 119 M 10
RMED-E 4.0 4,0 1 7,4 0211-RMed- E4.0 9,2 31,0 200 162 262 124 134 M 10
RMED-E 5.0 5,0 21,7 0211-RMed- E5.0 12,9 38,5 200 173 262 124 145 M 10
RMED-E 6.3 6,3 27,4 0211-RMed- E6.3 16,8 48,0 240 168 360 144 140 M 10
RMED-E 8.0 8,0 34,8 0211-RMed- E8.0 20,7 57,0 240 183 360 144 155 M 10

Rated pri: 400 V Copper Total


Model Power Approx. dimensions in mm
current sec: 230 V (115/0/115V) weight weight
single-phase kVA A Article-no. kg kg a b c d e Attachment
RMED-E 3.15 3,15 1 3,7 0212-RMed-E3.15 7,6 28,0 200 147 262 124 119 M 10
RMED-E 4.0 4,0 1 7,4 0212-RMed- E4.0 9,2 31,0 200 162 262 124 134 M 10
RMED-E 5.0 5,0 21,7 0212-RMed- E5.0 12,9 38,5 200 173 262 124 145 M 10
RMED-E 6.3 6,3 27,4 0212-RMed- E6.3 16,8 48,0 240 168 360 144 140 M 10
RMED-E 8.0 8,0 34,8 0212-RMed- E8.0 20,7 57,0 240 183 360 144 155 M 10

Delivery time: on short notice

G 1/2
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 3

R-MED
Three-phase isolating transformers
RMED-D 3.15-8.0 comp. DIN VDE 0570 part 2-15, EN 61558-2-15

Design: Open frame, stationary, for installation and set-up in dry rooms, separate win-
dings, sturdy mounting brackets. Connection to non-tracking transformer ter-
minals with screw connection. The terminals are protected against finger touch
or contact with the back of the hand in compliance to accident prevention regu-
lations (VBG 4).
Necessary settings for display resp. report of warm-up and isolation monitoring
are protruded.
IP 00, suitable for installation up to protection rating IP 23, insulation class E,
max. ambient temperature ta 40°C. Other type of protection and manufacture
comp. to other norms available on request.

Terminal set-up and


wiring diagram:

PTC: PTC resistor


SW: screening foil

Rated pri: 3x400 V Copper Total


Model Power Approx. dimensions in mm
current sec: 3x230 V weight weight
three-phase kVA A Article-no. kg kg a b c d e Attachment
RMED-D 3.15 3,15 7,9 0213-RMed-D3.15 1 1 ,3 31 ,2 300 140 260 224 94 M8
RMED-D 4.0 4,0 10,0 0213-RMed-D4.0 1 2,2 36,6 300 153 260 224 108 M8
RMED-D 5.0 5,0 12,5 0213-RMed-D5.0 1 2,6 41 , 1 300 165 260 224 120 M8
RMED-D 6.3 6,3 15,8 0213-RMed-D6.3 1 6,4 5 1,3 336 150 290 248 127 M8
RMED-D 8.0 8,0 20, 1 0213-RMed-D8.0 20,2 62,5 336 170 290 248 144 M8
Delivery time: on short notice

G 1/3
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 4

Portable plastic housings


for the electrical industry
RG 601 - RG 801

Design: Portable housings series RG 601 - RG 801 are made of robust and impact resi-
stant glass-fibre reinforced polyester resin. The housings are specially desi-
gned for application with electric units. They are self extinguishing and not hy-
groscopic. A neoprene seal fitted between cover and housing assures ade-
quate tightness. Tests in water depths of 1 m showed that no moisture pene-
trated for 8 consecutive days.

Temperature resistance: -32°C up to 220°C.

The housings are designed in IP 67 and available in colors blue, red and yellow
(please state in order). Other colors on request.

The housings can be fitted with boreholes and cutouts according to drawing at
a surcharge.

Model RG 601-701

Model RG 801

Total
Model Article no. Approx. dimensions in mm
weight

+ state color kg a b c a1 b1 c1 a2 b2 c2 density


RG 601 RG 601 1,1 1 156 150 17 6 166 166 219 148 140 160 3,0
RG 701 RG 701 1,76 176 176 217 192 192 259 169 169 205 3,0
RG 801 RG 801 4,16 240 250 280 310 265 – 210 210 248 4,0

G 1/4
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 5

Size 1 and above available with handle

Cutout for
cable gland

Bottom Bottom
size 00 - size 3 size 4 - size 4a

Base plate

rubber heels

hole for
cable gland hole for
acc. order cable gland
acc. order
Extra holes on request

Transformer housings with cable gland

Model L B H E E1 H1 H2 Model L B H E E1 H1 H2
Article no. Article no.
RG 0 120 95 90 70 35 10 3 RG 3 180 180 190 100 50 10 6
RG 1 140 110 110 80 40 10 6 RG 4 250 220 190 120 60 12,5 7
RG 2 180 180 150 100 50 10 6 RG 4a 310 220 190 120 60 12,5 7
Material: St. 1203 Plastic-coated color RAL 7032: flint stone grey unpolished

G 1/5
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 6

Punched holes on request only.

Transformer housings for wall mounting

Model L L1 B B1 H H1
Article no.
RG 5 a 125 127 118 124 75 79
RG 5 b 200 202 118 124 75 79
RG 5 c 125 127 118 124 100 104
RG 5 d 200 202 118 124 100 104
RG 8 a 250 252 160 166 100 104
RG 8 b 250 252 160 166 140 144
RG 10 300 302 220 226 150 154
Material: St. 1203 Plastic-coated color RAL 7032: flint stone grey unpolished

G 1/6
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 7

Housing top

Housing bottom

Transformer housings for wall mounting with punched holes for cable gland

Model
L L1 B B1 H H1 E E1 D PG
Article no.
RG 11 202 199 152 149 122 13 70 50 4,5 13,5
RG 12 202 199 152 149 155 13 70 50 4,5 13,5
RG 13 303 299 222 218 190 13 110 50 5,5 13,5
RG 14 382 379 302 298 220 13 110 60 6,5 16
RG 15 500 498 350 348 272 13 180 95 6,5 16
Material: St. 1203 Plastic-coated color RAL 7032: flint stone grey unpolished

G 1/7
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 8

Housing top also available without air slits

Floor housing

Floor housing Wall housing

RG 20-24 RG 20-29

RG 25-29

M4 thread set

Rubber heels riveted

Transformer housings sizes 20 - 29

Fixing brackets
Model A A1 B C
for wall mounting
Article no. ca. mm ca. mm ca. mm ca. mm Article no.
RG 20 94 118 90 110 WG 20
RG 2 1 114 138 110 130 WG 2 1
RG 22 134 158 130 150 WG 22
RG 23 174 198 160 200 WG 23
RG 24 224 248 180 180 WG 24
RG 25 274 298 220 220 WG 25
RG 26 334 358 250 300 WG 26
RG 27 374 398 280 280 WG 27
RG 28 454 478 350 300 WG 28
RG 29 534 558 380 300 WG 29
Material: St. 1203 Plastic-coated color RAL 7032: flint stone grey unpolished

G 1/8
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 9

Housing kit Extra sizes on request

Housing back Housing front


removable removable

M6 thread

with earthing screws

Angle for cable gland Angle for cable gland

cage nuts
adjustable
Transformer Available in:
mounting IP 20 - without lattice hole sheet metal
IP 23 - with lattice hole sheet metal
Housing frame IP 44 - with closed base plate
IP 54 - with closed base plate and hollow
section seal
Material: EPDM quality - self-sealing
M8 thread

Angle for cable gland U-angle yellow chromed

Housing kit without air slits

Model Material L L1 B B1 H U U1 U2
Article no.
UI 180
RG 110 520 460 460 400 480 500 460 289 –137
UI 210
RG 120 UI 240 580 520 510 450 560 550 510 349 –197
3 UI 150
RG 130 580 520 400 340 420 440 400 349 –197
3 UI 168
3 UI 180
RG 140 640 580 460 400 480 500 460 409 – 257
3 UI 210
RG 150 3 UI 240 740 680 510 450 560 550 510 509 – 357
RG 160 –– 825 765 590 530 620 630 590 616 – 332
RG 170 –– 1020 960 720 660 690 760 720 812 – 428
RG 180 –– 1120 1060 820 760 800 860 820 891 – 407
RG 190 –– 1310 1250 820 760 1250 860 820 1081 – 497
Material: St. 1203 Plastic-coated color RAL 7032: flint stone grey unpolished

G 1/9
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 10

Housing kit Extra sizes on request

Housing back Housing front


removable removable

M6 thread

with earthing screws

Angle for cable gland Angle for cable gland

cage nuts
adjustable
Transformer
mounting

Housing frame

M8 thread

Angle for cable gland U-angle yellow chromed

Available in:
IP 20 - without lattice hole sheet metal
IP 23 - with lattice hole sheet metal
IP 44 - with closed base plate
IP 54 - with closed base plate and hollow section seal Material: EPDM quality - self-sealing

Housing kit with air slits

Model Model L L1 B B1 H U U1 U2
Article no.
RG 210 –– 720 660 550 490 620 590 550 470 – 406
RG 220 –– 810 750 460 400 800 500 460 512 – 448
RG 230 –– 910 850 610 550 730 650 610 590 – 5 1 8
RG 240 –– 1060 1000 560 500 1000 600 560 632 – 568
RG 250 –– 1260 1200 760 700 1100 800 760 812 – 748
Material: St. 1203 Plastic-coated color RAL 7032: flint stone grey unpolished

G 1/10
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 11

Riedel floor housing in IP 23

M6 thread set

Available on request at a surcharge:


- holes for cable glands acc. customer data
- cable glands acc. customer data
- other colors, for example RAL 6011/9001

Floor housing for transformers without holes for cable glands

Total
Model A C A1 B1 C1 A2 B2 A3 x B3 Mounting
weight
Article no. kg app. mm app. mm app. mm app. mm app. mm app. mm app. mm app. mm Floor
RG 300 26 340 400 380 380 500 360 360 320 x 300 Ø 13
RG 310 36 410 500 450 450 600 430 430 390 x 370 Ø 13
RG 320 56 560 600 600 600 700 580 580 540 x 520 Ø 13
Material: St. 1203 Color RAL 7032: flint stone grey unpolished

G 1/11
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 12

Custom makes

Apart from our standard stock program we design and manufacture custom
made specials. We assist to realize your ideas until initial operation and docu-
mentation has been reached.
Following some examples of power supply and testing

Stationary and mobile test


systems, operation and control
manually or via PLC

A.C. and D.C. sources, infinitely


variable for example
A.C. or D.C. 0 - 8000 A,
A.C. or D.C. 0 - 5000 V.

Picture on the right: infinitely


variable D.C. source 500A with
residual ripple < 20mV

G 1/12
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 13

Universal steel cabinets RGS


(setup wall or floor)

Cabinet with galvanized, pre-assembled board, wall mounting (with accessories also floor setup), structured and
powder-coated surface, 100% polyester, tone RAL 7032,
Protection IP66 (IP55 for *2-door cabinets), safety against mechanical damage IK10, door easy to unhinge with
left hinge (right on request), 3 mm double bit lock, earthing screw M6x16 on door and cabinet body, pre-embos-
sed cable gland plates (on top for floor cabinet)
Custom makes: on request different tone, cable glands, earthing strips, transformer and accessories installed,
special labelling, safety- and other locks

Model Height Width Depth Locks Total weight


Article no. mm mm mm Quantity kg
RGS315 300 200 150 1 3,5
RGS302 300 150 1 4,5
RGS303 300 200 1 5,0
RGS312 400 150 1 6,0
RGS317 400 300 150 1 6,0
RGS318 300 200 1 6,5
RGS319 400 200 1 8,0
RGS331 600 200 1 13,0
RGS332 600 250 1 13,5
RGS321 500 300 200 1 9,0
Standard cabinet RGS323 400 200 1 11,5
RGS324 400 250 1 12,0
RGS322 500 200 1 13,0
RGS325 500 250 1 14,5
RGS326 600 400 200 3P 13,5
RGS327 400 250 3P 14,0
RGS328 600 200 3P 18,0
RGS329 600 250 3P 19,5
RGS330 600 300 3P 21,0
RGS339 600 400 3P 23,0
RGS337 800 300 3P 30,5
RGS335 700 500 250 3P 19,5
RGS343 800 600 200 3P 27,5
RGS356 600 250 3P 29,0
RGS357 600 300 3P 31,0
Custom make RGS344 600 400 3P 34,5
RGS345 800 250 3P 39,8
RGS346 800 300 3P 41,8
RGS347* 1000 300 3P 50,5
RGS354 1000 600 250 3P 38,5
RGS359 600 400 3P 44,0
RGS360 800 250 3P 48,5
RGS361 800 300 3P 50,5
RGS362 800 400 3P 55,0
RGS363* 1000 300 3P 65,0
RGS370 1000 300 3P 66,0
RGS366* 1200 300 3P 77,5
RGS364 1200 800 300 3P 63,0
RGS367 800 400 3P 68,0
RGS365* 1000 300 3P 76,0
Custom make RGS371 1000 300 3P 77,5
* 2-door cabinets

Pedestal (100 mm U-sectional steel) re-inforced heavy-duty base plate for floor setup
Article no. Cabinet depth Article no. floor space Article no. floor space Article no. floor space
RGSO200 200 RGSP420 400x200 RGSP525 500x250 RGSP830 800x300
RGSO250 250 RGSP520 500x200 RGSP625 600x250 RGSP103 1000x300
RGSO300 300 RGSP620 600x200 RGSP825 800x250 RGSP640 600x400
RGSO400 400 RGSP425 400x250 RGSP630 600x300 RGSP840 800x400

Delivery time: on short notice Subject to technical modifications


G 1/13
G_TEIL_041019.qxd 19.10.2004 10:30 Seite 14

Inrush current limiters


single and three-phase

RESBE and RESBD


Transient pulses may occur when switching-on energy consumers. Transient pulses cause undesired triggering of fuse
elements. In such cases inrush current limiters are optimal for selective fusing.
Following we state typical energy consumers featuring high inrush currents resp. starting currents.

Typical Typical
Current
Consumer Inrush / Rated Inrush- resp.
abating
Current Start-up time
Transformers 1) 10-40 ms rapid
Dynamo sheet core 0,5mm 10-18 fold
grain-oriented sheet 15-25 fold
Toroidal core transformer 30-50 fold

Rectifier incl. filter


10-40 fold 5-40 ms rapid
capacitors 2)
Contactors 3-10 fold 10-40 ms rapid
Magnet valves etc. 10-20 fold 0,05-0,2 s rapid to slow
Filament lamp 10-15 fold ca. 0,3 s slow

1) Depending on frequency and transformer design (induction). Deviations are possible.


2) Depending on total capacity, connections and network impedance. Deviations are possible.

Commercial fuses and circuit breakers may be used when applying our inrush current limiters series RESBE and
RESBD.
Series RESBE and RESBD are part of our patent application "Inrush current limit including time controlled second swit-
ching element".
To eliminate bridging current rush the load on-period should be higher than the effective inrush current limit. If this is not
the case we recommend option "release output" for loads with release input resp. remote input / output.

RESBE RESBE RESBE RESBE RESBE RESBE RESBD RESBD


ELECTRICAL DATA
230V 4A 230V 10A 230V 16A 115V 16A 400V 16A 208V 16A 400V 16A 208V 16A
Rated voltage Urated AC 230V AC 230V AC 230V AC 115V AC 400V AC 208V 3AC 400V 3AC 208V
Voltage range Umin-Umax AC 195-264V AC 195-264V AC 195-264V AC 85-132V AC 340-460V AC 176-240V 3AC 340-460V 3AC 176-240V
Frequency 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz
Overvoltage protection varistor varistor varistor varistor varistor varistor varistors varistors
Rated current max 4A 10A 16A 16A 16A 16A 16A 16A
Highest transient pulse typ. < 8A < 5ms < 18A < 5ms < 36A < 5ms < 18A < 5ms < 32A < 5ms < 32A < 5ms < 32A < 5ms < 17A < 5ms
(@ Ta=25°C/Umax)
Highest transient pulse typ. < 18A < 5ms < 56A < 5ms < 104A < 5ms < 53A < 5ms < 96A < 5ms < 96A < 5ms < 96A < 5ms < 44A < 5ms
(@ Ta=60°C/Umax)
Efficiency current limit < 1s < 1s < 1s < 1s < 1s < 1s < 1s < 1s
Maximum switching rate 30 1/h 30 1/h 30 1/h 30 1/h 30 1/h 30 1/h 30 1/h 30 1/h
Status reports LED green LED green LED green LED green LED green LED green LED green LED green
OPERATION DATA
Protection class comp. EN 60529 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20
Ambient temperature 0 to 60°C 0 to 60°C 0 to 60°C 0 to 60°C 0 to 60°C 0 to 60°C 0 to 60°C 0 to 60°C
Storage temperature -25 to +85 °C -25 to +85 °C -25 to +85 °C -25 to +85 °C -25 to +85 °C -25 to +85 °C -25 to +85 °C -25 to +85 °C
Cooling natural natural natural natural natural natural natural natural
convection convection convection convection convection convection convection convection
MECHANICS
Connection input L1-N L1-N L1-N L1-N L1-L2 L1-L2 L1-L2-L3 L1-L2-L3
connector 0,2-4mm²
Connection output T1-T T1-T T1-T T1-T T1-T2 T1-T2 T1-T2-T3 T1-T2-T3
connector 0,2-4mm²
Fitting on DIN-rail ja ja ja ja ja ja ja ja
comp. DIN EN 50022
Installation position any any any any any any any any
Weight without / with 225g / 250g 215g / 240g 215g / 240g 215g / 240g 225g / 250g 215g / 240g 235g / 260g 235g / 260g
counterplug
Measurements in mm with 51 x 105 x 127 51 x 105 x 127 51 x 105 x 127 51 x 105 x 127 51 x 105 x 127 51 x 105 x 127 51 x 105 x 127 51 x 105 x 127
counterplug (W x H x D)
Measurements in mm without 51 x 105 x 113 51 x 105 x 113 51 x 105 x 113 51 x 105 x 113 51 x 105 x 113 51 x 105 x 113 51 x 105 x 113 51 x 105 x 113
counterplug (W x H x D)
OPTIONS (at a surcharge)
Release-output 3-30VDC 3-30VDC 3-30VDC 3-30VDC 3-30VDC 3-30VDC 3-30VDC 3-30VDC
to switch-on load
Connection release +/- +/- +/- +/- +/- +/- +/- +/-
connector 0,14-2mm²
Other voltages yes yes yes yes yes yes yes yes
Other frequencies 16²/³-400 Hz 16²/³-400 Hz 16²/³-400 Hz 16²/³-400 Hz 16²/³-400 Hz 16²/³-400 Hz 16²/³-400 Hz 16²/³-400 Hz
Other currents yes yes yes yes yes yes yes yes
Other highest transient pulses yes yes yes yes yes yes yes yes
Efficiency, adjustable prior to 0,2-1 s 0,2-1 s 0,2-1 s 0,2-1 s 0,4-1 s 0,2-1 s 0,4-1 s 0,3-1 s
delivery

Delivery time: on short notice Subject to technical modifications


G 1/14
t
t

ä
ä
rd/qf/09.04/2000

Michael Riedel

t
t

Transformatorenbau GmbH

i
i
Transformatorenbau GmbH

l
l

a
a
Produktion: www.querformat.info

u
u

Q
Q

r
r

ü
ü

f
f

w
w

o
o

h
h

-
-

w
w

o
o

n
n

K
K

s
s

a
a

d
d

n
n

e
e

b
b

Michael Riedel

a
a

2004

Transformatorenbau GmbH 2004

h
h

Max-Eyth-Straße 10 · D-74532 Ilshofen-Eckartshausen


Telefon (0 79 04) 7 04-0 · Fax (0 79 04) 7 04 50

r
r

www.riedel-trafobau.de · info@riedel-trafobau.de

i
i

W
W

Potrebbero piacerti anche