Sei sulla pagina 1di 2

Failure Printouts (2000-3999) 2725 ADJACENT CELL IDENTIFIER CONFIGURA-

TION ERROR

249 2725 ADJACENT CELL IDENTIFIER CONFIG-


URATION ERROR
Meaning
Adjacent cell information has been defined incorrectly in the BSDATA
(BSS Radio Network Configuration Database). Either the MSC or the
source BSC can detect the error during an external handover. When the
error has been detected, the handover attempt is interrupted.

The following counters are updated:

- When the MSC detects the error


HANDOVER MEASUREMENTS:
004100 MSC_O_ADJ_CELL_ID_ERR
CLEAR CODE MEASUREMENTS:
500926 M_INVALID_CELL

- When the BSC detects the error


HANDOVER MEASUREMENTS:
004100 MSC_O_ADJ_CELL_ID_ERR
CLEAR CODE MEASUREMENTS:
500513 ADJ_CELL_ID_ERR

Supplementary information fields


1 identification of the BTS. Identification of the source
BTS of the failed handover attempt. The adjacent cell information
of the source BTS is incorrect

2 event identifier

0 the MSC has detected an error in the adjacent cell definitions.


Supplementary information fields 3, 4 and 5 cannot be defined
1 the BSC has detected an error in the adjacent cell definitions.
Supplementary information fields 3, 4 and 5 are the identifiers
of the target cell set by the MSC

3 identification of the target cell

0-FF BCC (Base Station Colour Code). The target cell where
handover has been attempted. The value is set by the MSC
FF information is not available

4 identification of the target cell

0-FF NCC (Network Colour Code). The target cell where


handover has been attempted. The value is set by the MSC
FF information is not available

5 identification of the target cell

DN9813051 Id:0900d80580a6bd62 477


Confidential
2725 ADJACENT CELL IDENTIFIER CONFIGURA- Failure Printouts (2000-3999)
TION ERROR

1-FFFF BCCH of the target cell where handover has been


attempted. The value is set by the MSC
FFFF (65535d) frequency information is not available

Instructions
Check the adjacent cell information of the BTS in supplementary
information field 1 in the BSDATA. If the BSC has detected the error,
supplementary information fields 3, 4 and 5 identify the cell that
the MSC has defined as the target cell.

Check the adjacent cell definitions with the MML command:

ZEAO:BTS=<BTS identification>;

Use the BTS's adjacent cell definitions to check the adjacent cell
identification information (LAC and CI) of either the adjacent cells
in the target cell list or all adjacent cells in other BSSs.

Cancelling
Cancel the alarm with an MML command after correcting the fault as
presented in INSTRUCTIONS. See instructions on alarm administration.

478 Id:0900d80580a6bd62 DN9813051