Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
2
PACO KP, KPV
1
1. Features and benefits
KPV pumps
• Same great features of KP, but in a vertical
configuration for optimized space savings
• Optional lower sleeve bearing design for easier
lower bearing maintenance.
3
2 PACO KP, KPV
2. Applications
Applications
Commercial systems
Liquid transfer and pressure boosting in:
• air conditioning, primary and secondary chilled
Industrial systems
Liquid transfer and pressure boosting in:
• process cooling and chilled water systems
• water condensing systems and cooling towers
• boiler feed and condensate systems
• industrial heating systems
• wash down and cleaning systems
GR 2910
• industrial processing systems (water, light
chemicals, oils, etc).
4
PACO KP, KPV
3
3. Product range
Product range
Pump configurations
Standard configuration Optional configuration
5
4 PACO KP, KPV
4. Performance range
Performance range
Paco KP pumps are available with 2-, 4- or 6-pole 1. Go into the relevant performance range chart.
motors. 8 and 10 pole are available on request. 2. Find your duty point.
The next three pages show the performance range 3. Note which pump type covers your duty point.
covered by these three motor types. 4. Go to section "Product range" and then to
Knowing your required duty point, use the performance "Performance curves and technical data" and find
ranges like this: more detailed information on your chosen pump.
KP 2-pole
2000
Q [US GPM]
Q [m³/h]
3550 rpm, 60 Hz
4012-7/8
KP
1500
300
4012-1/2
1000
200
800
3095-7/8
600
500
90 100
400
80
2095-1/2
70
300
60
250
50
200
40
150
30
100
23
400
300
200
150
120
100
80
[ft]
H
100
90
80
70
60
50
40
30
25
[m]
H
6
H H
[m] [ft] KP
800 1780 rpm, 60 Hz
200
KP 4-pole
600
1024-3/4
500
PACO KP, KPV
400 6020-3/4
100 6019-7/8
8020-5/6 1020-3/4
80 250
70 4015-9/0
60 200
5015-9/0
50
150
2013-5/6 3014-7/8 6015-3/4 8015-3/4 1015-3/4
40
1415-1/2
30 100 4012-7/8
80
2095-1/2
6012-3/4 1012-1/2
20
60
3095-7/8 4012-1/2 5012-7/8
50
40
8012-5/6
10
25
20
15
100 150 200 250 300 400 500 600 800 1000 1500 2000 3000 4000 6000 10000 15000
Q [US GPM]
23 30 40 50 60 70 80 100 200 300 400 500 600 800 1000 2000 Q [m³/h]
7
Performance range
4
Performance range
4
8
H H
[m] [ft] KP
400
1180 rpm, 60 Hz
KP 6-pole
100
300
80
1024-3/4
70
60 200
50
150 6019-7/8 6020-3/4
40 8020-5/6
120
1020-3/4 1220-5/6
30 100
1015-3/4
80
20
60
50
8015-3/4 1415-1/2
40
10
30
8 1012-1/2
7
6 20
5
15
4
12
10
400 500 600 800 1000 1500 2000 2500 3000 4000 5000 6000 8000 10000 15000
Q [US GPM]
100 200 300 400 500 600 700 800 1000 2000 Q [m³/h]
Construction
Paco KP horizontal split case pumps are available in
several different construction types.
KP pump, construction X2
All four construction types are available with packing
as an option.
Sectional view
9
5 PACO KP, KPV
KP pump, construction X4
Construction
Sectional view
113d
11a
54
114a
79 124
6b 116a
105 24
10
PACO KP, KPV
5
KP pump, construction X5 and X7
Construction
Sectional view
11
5 PACO KP, KPV
Sectional view
12
PACO KP, KPV
5
KP pump, typical end view - Horizontal
Construction
(Non-drive end)
13
5 PACO KP, KPV
14
PACO KP, KPV
5
Mechanical construction Bearings
Construction
KP pumps are fitted with two standard single-row
Pump casing deep-groove ball bearings. The bearings are of the
The class 35 grey iron volute pump casing has radial open type permitting the bearings to be relubricated.
suction port and radial discharge port. The bearings are lubricated by Grundfos prior to
The pumps are of the inline (symmetric) design. delivery.
Seal housings
All KP pumps have two seal housings (pos. 124), one
at the drive end and one at the non-drive end of the
pump shaft.
Shaft
The shaft (pos. 51) is of the key and keyway type with
one key for the impeller (pos. 11) and one key for the Fig. 14 Double-suction impeller
coupling (pos. 11a).
The shaft is supported by bearings at both the drive All impellers are dynamically balanced in accordance
end and the non-drive end of the pump. with ANSI/ISO 1940 Class G6.3 standard. Due to their
design, the impellers are inherently hydraulically
balanced and thus compensate for axial thrust.
All impellers are trimmed to the duty point required by
the customer.
Wear rings
TM04 0477 0708
15
5 PACO KP, KPV
The coupling design assists in reducing vibrations and The packing rings consist of braided material which is
Construction
cushions shock loads. The design also extends the life effective for long service life for packing rings while
of the coupling itself. The flexible grid is standard for protecting the shaft sleeve.
VFD driven pumps.
Pos. Description
1 Shaft sleeve
2 Gland
TM05 5784 3812
3 Packing ring
4 Lantern ring
A Drilled hole for flushing liquid (pumped liquid)
Base
Fig. 16 elastomeric coupling Pump and motor are mounted on a common base
frame designed according to Hydraulic Institute
Mechanical shaft seal standard, ANSI/HI 1.3-2000.
The material of the standard version is Buna Carbon/
Painting
ceramic.
Prior to delivery to the customer, pump, motor and
base are top coated with a blue paint (RAL 5015);
coating thickness is 2 to 4 mils.The inside of the pump
is primered for corrosion resistance. Standard units are
not painted internally.
TM04 0472 0708
Packing
Includes graphite impregnated packing rings.
16
PACO KP, KPV
5
Test pressure
Construction
Pressure testing is made with water at ambient
temperature. The standard hydrostatic test pressure is
1.5 times the flange rating pressure.
Chart B
Maximum case working pressure (class 125 Flange)
Pump model number 6019 6020 8020 1020 1024 1220
Cast iron
175 psi
Ductile iron
Maximum case working pressure (class 250 Flange)
Pump model number 6019 6020 8020 1020 1024 1220
Cast iron 250 psi 250 psi 234 psi 222 psi 250 psi 211 psi
Ductile iron 375 psi 375 psi 351 psi 333 psi 375 psi 317 psi
CWP: maximum Case Working Pressure based upon flange drilling. Maximum working pressure for a given application is determined by adding the
maximum available suction pressure to the shut-off head of a given impeller diameter.
Hydro: Is the hydrostatic test pressure applied to the pump. Minimum hydrostatic test pressure is 1.5 times maximum allowable case working pressure.
17
6 PACO KP, KPV
6. Operating conditions
Operating conditions
20 25 30 35 40 45 50 55 60 65 70 T [°C]
the carbon seal face leading to reduced seal life.
70 80 90 100 110 120 130 140 150 160 T [°F]
Buna
3280 7382 11483 15584 [ft] NBR (nitrile) rubber covers a wide range of liquids at
Fig. 19 Relationship between motor output (P2) and temperatures below 212 °F [+100 °C].
ambient temperature • Good mechanical properties
• Standard material
Liquid temperatures and shaft Viton
seals FKM rubber covers a very wide range of liquids and
The maximum liquid temperature marked on the pump temperatures.
nameplate depends on the mechanical shaft seal used: • Poor mechanical properties at low temperatures
• Temperature range for Buna - standard): • Resistant to water up to 275 °F [+135 °C]
32 °F to 212 °F [0 °C to +100 °C]. • Resistant to mineral oils and vegetable oils
• Temperature range for Viton • Not resistant to alkaline liquids at high
54 °F to 212 °F [+15 °C to +100 °C]. temperatures.
• Temperature range for EPDM EPDM
54 °F to 275 °F [+15 °C to +135 °C]. EPDM Rubber covers a wider range of liquids up to a
max temperature of 275 °F [135 °C].
Shaft seal • Good mechanical properties.
The materials of the shaft seal types used in KP pumps
have certain characteristics. These characteristics may Pressure
be of importance when choosing the shaft seal for the
pump. Maximum inlet pressure
Inlet pressure + pump pressure must always be lower
than maximum pressure of the pump.
Minimum inlet pressure
The minimum inlet pressure must correspond to the
NPSH curve for the pump.
18
PACO KP, KPV
6
Flow
Operating conditions
Minimum flow rate
The pump must not run against a closed discharge
valve, as this will cause an increase in temperature/
formation of steam in the pump. This may cause shaft
damage, impeller erosion, short life of bearings, stuffing
boxes with packing rings or mechanical seals due to
stress or vibration.
The minimum, continuous flow rate must be at least
25% of the flow rate at best-efficiency point (BEP).
19
PACO KP, KPV
construction code 24
30
(21) + (22)
Dbl Ext Shaft
31 Dbl Wear Rings
Example 29 60123 140001 1852
General configuration (horizontal)
Product code Code no Item
Model code 32 Recirc Lines
Materials of construction 34 (31) + (32)
Motor code 70 250 lb. Flange
71 Dbl Wear Rings
Production code 29 72 (71) + (73)
29: Split case 73 Recirc Lines
90 250 lb. Flange
Model code 60 12 3 91 Dbl Wear Rings
Pump discharge General configuration (Vertical)
20 = 2" Code no Item
30 = 3" 50 Std
40 = 4" 51 Dbl. Wear Rings
50 = 5"
60 = 6" 52 Sleeve Bearing
80 = 8" 80 250 lb. flamge
10 = 10" 81 Dbl. Wear Rings
12 = 12" 82 Sleeve Bearing
14 = 14"
92 250 lb. flamge
Nominal maximum impeller diameter
95 = 9.5" 93 Dbl. Wear Rings
12 = 12" Shaft/Sleeve Metallurgy
13 = 13" 0 = Steel/Bronze
14 = 14" 1 = Steel/S.S.
15 = 15"
19 = 19" 3 = S.S.l/Bronze*
20 = 20" 6 = S.S./S.S. or S.S./no sleeves
24 = 24" 7 = SS/Hard. SS
Impeller design A = 316 SS/Ni Al Bz
Clockwise rotation: X = Special
1, 3, 5, 7, 9
Counter clockwise rotation: Pump Metallurgy
0, 2, 4, 6, 8 1 = Brz. Fitted
2 = Std. All Bronze
Materials of construction 1 4 00 0 1 5 = All Iron
8 = Ductile Iron/Brz. Fitted
Packing or seal
3 = Standard Packing X = Special
1 = Type 21, Single Seal, Ceramic Seat, Buna
2 = Type 21, Single Seal, Tung Crbd Seat, Viton Motor code 1 78 2
6 = Type 21, Single Seal, Ni-Resist Seat, Viton Enclosure
7 = Type 21, Single Seal, Ni-Resist Seat, Buna 1 = ODP
8 = Type 1B, Single Seal, Ni-Resist Seat, Buna 2 = TECF
9 = Type 21, Single Seal, Ni Resist Seat, Viton 3 = explosion proof
A = Type 1, Single Seal, Ceramic Seat, Buna Voltage
B = Type 1, Single Seal, Ni-Resist Seat, Viton 1 phase 3 phase
C = Type 1, Single Seal, Tung Cbrd Seat, Viton HP
115/230 V 200 V 230/460 V
D = Type 1, Singel Seal, Ni Resist Seat, Buna 1/3 21 23 24
E = Type 1, Single Seal, Ceramic Seat, Buna 1/2 29 31 32
F = Type 1, Single Seal, Si Cbrd Seat, EPDM 3/4 35 37 38
ID of packing or seal 1 41 43 44
2 = 1" 1-1/2 47 49 50
3 = 1-1/4" 2 53 55 56
E = 1-1/2" 3 59 61 62
5 65 67 68
4 = 1-3/4" 7-1/2 71 73 74
5 = 2-1/4" 10 76 77 78
6 = 2-3/4" 15 -- 81 82
7 = 3" 20 -- 84 85
K = 3-1/2" 25 -- 01 87
V = 4" 30 -- 02 88
General configuration (horizontal) 40 -- 03 89
50 -- 04 90
Code no Item 60 -- 05 91
00 Std. 75 -- 06 92
01 Dbl- wear rings 100 -- 07 93
125 -- -- 94
02 Oil lube brgs 150 -- -- 95
03 (01) + (02) 200 -- -- 96
04 (01) + (05) 250 -- -- 97
300 -- -- 98
05 Recirc lines RPM
20 Dbl Ext Shaft 1 = 3500
21 Dbl Wear Rings 2 = 1750
3 = 1150
22 Recirc Lines
20
PACO KP, KPV
7
7. Curve charts and technical data
180
50 160
140
40 NPSH
120 [ft] [m]
30 100 100 30
80 80
20 20
60 60 The NPSH curve
40 40
is an average
10 10 curve for all
NPSH
20 20 variants shown.
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
140 70
100
The eta curves
120 60 show the efficiency
80 /6.75 /7.5 /8.125 /8.75 /9.5 of the pumps shown
100 50
60 80 40
/9.5
The power curves
60 30 indicate pump input
40 /8.75
power [P2] for the
40 /8.125 20
pumps shown
20 /7.5
20 /6.75 10
0 0 0
TM05 5009 3212
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
21
7 PACO KP, KPV
The guidelines below apply to the curves shown in the Requested tests are performed according to Hydraulic
performance charts. Institute. Performance tests are only completed when
• Tolerances according to: Hydraulic Institute. ordered with the pump.
• The curves show pump performance with different
impeller diameters at the nominal speed. Witness test
• The bold part of the curves show the
When the pumps are being tested it is possible for the
recommended operating range.
customer to witness the testing procedure according to
• Do not operate the pump along the thin parts of the Hydraulic Institute.
curves. If your duty point lies here, you should
If the customer wants to witness the pump test this
select a smaller or larger pump type.
request must be submitted with the order.
• Do not use the pumps at minimum flows below 0.1 x
Qmax stated on the pump name plate because of the
risk of overheating of the pump.
• The curves apply to the pumping of airless water at
a temperature of 77 °F [+20 °C] and a kinematic
viscosity of 1 cSt [1 mm2/s].
• ETA: The lines show values of the hydraulic
efficiency of the pump for the different impeller
diameters.
• NPSH: The curves show average values measured
under the same conditions as the performance
curves.
When sizing the pump, add a safety margin of at
least 1.6 ft [0.5 m].
• In case of other densities than 62.3 lb/ft3 [1000 kg/
m3] the discharge pressure is proportional to the
density.
• When pumping liquids with a specific gravity higher
than 1.0, motors with correspondingly higher
outputs must be used.
Calculation of total head
The total pump head consists of the height difference
between the measuring points + the differential head +
the dynamic head.
22
PACO KP, KPV
7
KP 2095-1/2 [2-pole]
340
100
320
/8.125
300
90
280
80 /7.5
260
240
70
220
/6.75
60 200
180
50 160
140
40 NPSH
120 [ft] [m]
30 100 100 30
80 80
20 20
60 60
40 40
10 10
20 NPSH 20
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
140 70
100
120 60
80 /7.5 /8.125 /8.75 /9.5
/6.75
100 50
60 80 40
/9.5
60 30
40 /8.75
40 /8.125 20
20 /7.5
20 /6.75 10
0 0 0
TM05 5009 3212
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
23
7 PACO KP, KPV
KP 3095-7/8 [2-pole]
Curve charts and technical data
H H
[m] [ft]
420 /9.5 KP 3095-7/8
400 60 Hz, n = 3550 rpm
120
380
110 360
/8.75
340
100
320
300 /8
90
280
80 260
240 /7.25
70
220
60 200 /6.5
180
50 160
140
40 NPSH
120 [ft] [m]
30 100 100 30
80 80
20 20
60 60
40 40
10 10
20 NPSH 20
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
160 80
100 140 70
/9.5
120 /8.75 60
/9.5
80 /6.5 /7.25 /8
100 50
/8.75
60 80 40
/8
60 30
40
/7.25
40 20
/6.5
20
20 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1000Q [US GPM]
TM05 5010 3212
24
PACO KP, KPV
7
KP 4012-1/2 [2-pole]
90 300
/8.4
280
80 260
240
70 /7.5
220
60 200
180 /6.5
50 160
NPSH
140 [ft] [m]
40
120 120
30 100 100 30
80 80
20 20
60 60
40 40
10 NPSH 10
20 20
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
320 80
200 280 70
/9.4 /10.3
/8.4
240 /7.5 60
160 /6.5
200 50
/10.3
120 160 40
120 /9.4 30
80
80 /8.4 20
40 /7.5
40 /6.5 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
25
7 PACO KP, KPV
KP 4012-7/8 [2-pole]
Curve charts and technical data
H H
[m] [ft]
120
400 KP 4012-7/8
/9.4
380 60 Hz, n = 3550 rpm
110 360
340 /8.8
100
320
300 /8.2
90
280
80 260 /7.6
240
70
220 /7.0
60 200
180
50 160
NPSH
140
40 [ft] [m]
120 120
30 100 100 30
80 80
20 20
60 60
40 40
10 NPSH 10
20 20
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
400 80
250 350 70
300 /9.4 60
200 /8.8
250 /8.2 50
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000Q [US GPM]
26
PACO KP, KPV
7
KP 2095-1/2 [4-pole]
90
/8.75
25
80
/8.125
70
20
/7.5
60
/6.75
15 50
40
NPSH
10
[ft] [m]
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
14 70
10
12 60
8 /6.75 /7.5 /8.125 /8.75 /9.5
10 50
6 /9.5
8 40
/8.75
6 30
4
/8.125
4 20
/7.5
2
2 /6.75 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 Q [US GPM]
TM05 5013 3912
0 10 20 30 40 50 60 Q [m³/h]
27
7 PACO KP, KPV
KP 2013-5/6 [4-pole]
Curve charts and technical data
H H
[m] [ft]
KP 2013-5/6
200 60 Hz, n = 1780 rpm
60
/13
180
50 /12
160
140 /11
40
120
/10
30 100
/9
80
NPSH
20 [ft] [m]
60 30
8
40 20 6
10
4
20 10
NPSH
2
0 0 0 0
0 40 80 120 160 200 240 280 320 360 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
60 60
40
50 /13 50
/12
30 /11
40 /10 40
/9
30 30
20
/13
20 /12 20
/11
10
/10
10 /9 10
0 0 0
0 40 80 120 160 200 240 280 320 360 Q [US GPM]
TM05 5014 3912
0 20 40 60 80 Q [m³/h]
28
PACO KP, KPV
7
KP 3095-7/8 [4-pole]
90
/8.75
25
80
/8
70
20
60 /7.25
15 50 /6.5
40
NPSH
10
[ft] [m]
30 15
4
20 10 3
5
NPSH 2
10 5
1
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
32 80
20 28 70
/9.5
24 /8.75 60
/7.25 /8
16 /6.5
20 50
12 16 /9.5 40
12 /8.75 30
8
/8
8 20
4 /7.25
4 /6.5 10
0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]
TM05 5015 3912
29
7 PACO KP, KPV
KP 3014-7/8 [4-pole]
Curve charts and technical data
H H
[m] [ft]
70
/14.0
KP 3014-7/8
220 60 Hz, n = 1780 rpm
200
60
/13.0
180
50 /12.0
160
140 /11.0
40
120
/10.0
30 100
80
NPSH
20
[ft] [m]
60 60
15
40 40
10 10
20 20
5
NPSH
0 0 0 0
0 100 200 300 400 500 600 700 800 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
60 /14.0 70
/11.0 /12.0 /13.0
40 /10.0
/14.0
50 60
30 40 /13.0 50
30 /12.0 40
20
/11.0
20 30
/10.0
10
10 20
0 0 10
TM05 5016 3212
0 100 200 300 400 500 600 700 800 Q [US GPM]
TM05 5016 3912
30
PACO KP, KPV
7
KP 4012-1/2 [4-pole]
100 /9.9
30
90
25
80
/8.7
70
20
60
/7.6
15 50 NPSH
[ft] [m]
40 /6.5 40 12
10 10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 100 200 300 400 500 600 700 800 900 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
40 80
25 35 70
/11.0
30 /8.7 /9.9 60
20 /7.6
25 /11.0 50
/6.5
15 20 40
/9.9
15 30
10
/8.7
10 20
5 /7.6
5 10
/6.5
0 0 0
TM05 5017 3212
0 100 200 300 400 500 600 700 800 900 Q [US GPM]
TM05 5017 3912
31
7 PACO KP, KPV
KP 4012-7/8 [4-pole]
Curve charts and technical data
H H
[m] [ft]
160
/12.0 KP 4012-7/8
60 Hz, n = 1780 rpm
150
45
140
40 130 /10.8
120
35
110
/9.5
30 100
90
25
80
/8.3
70
20
60
/7.0
15 50 NPSH
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
80 80
/12.0
50 70 70
/10.8
/9.5
60 60
40 /8.3
50 50
/7.0 /12.0
30 40 40
/10.8
30 30
20
20 /9.5 20
10 /8.3
10 10
/7.0
0 0 0
TM05 5018 3212
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
TM05 5018 3912
32
PACO KP, KPV
7
KP 4015-9/0 [4-pole]
80 260
/14.0
240
70
220
60 200
/12.5
180
50
160
/11.0
140
40
120
/9.5
30 100
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 20
5
NPSH
0 0 0 0
0 200 400 600 800 1000 1200 1400 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
160 80
60 /12.5 30
40
40 /11.0 20
20 /9.5
20 10
0 0 0
TM05 5019 3212
33
7 PACO KP, KPV
KP 5012-7/8 [4-pole]
Curve charts and technical data
H H
[m] [ft]
KP 5012-7/8
180 60 Hz, n = 1780 rpm
50 /12.0
160
140
40 /10.75
120
/9.5
30 100
NPSH
[ft] [m]
80 40 12
/8.25
20
60 30
/7.0
8
40 20
10
4
20 10
NPSH
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
P2 Eff
[kW] [%]
90 90
80 80
70 /12.0 70
/9.5 /10.75
60 /9.5 60
/7.0 /12.0
50 50
40 40
/10.75
30 30
/9.5
20 20
/9.5
10 10
/7.0
0 0
TM05 5020 3212
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
TM05 5020 3912
34
PACO KP, KPV
7
KP 5015-9/0 [4-pole]
240
70
220
/13.5
60 200
180
50 /12.0
160
140
40
/10.5
120
30 100
/9.0
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 20
NPSH 5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
320 80
/12.0 /13.5 /15.0
200 280 /10.5 70
240 /9.0 60
160
200 50
120 30
80
/13.5
80 20
/12.0
40
40 /10.5 10
/9.0
0 0 0
TM05 5021 3212
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
TM05 5021 3912
35
7 PACO KP, KPV
KP 6012-3/4 [4-pole]
Curve charts and technical data
H H
[m] [ft]
170 KP 6012-3/4
/12.0
50 60 Hz, n = 1780 rpm
160
150
45
140
/10.75
40 130
120
35
110
/9.5
30 100
90
25 /8.25
80
70
20
60 /7.0
50 NPSH
15
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
4
10 NPSH 10
2
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
280 90
200
240 80
160 /12.0
200 /10.75 70
120 50
80 /7.0
/12.0
80 40
/10.75
40
40 /9.5 30
/8.25
/7.0
0 0 20
TM05 5023 3212
36
PACO KP, KPV
7
KP 6015-3/4 [4-pole]
180
50 /12.0
160
140
40 /10.5
120
30 100
/9.0
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 20
NPSH 5
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
320 90
200 280 80
/12.0 /13.5 /15.0
240 /10.5 70
/9.0
160
200 /15.0 60
120 160 50
/13.5
120 40
80 /12.0
80 30
/10.5
40
40 /9.0 20
0 0 10
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
TM05 5024 3912
37
7 PACO KP, KPV
KP 6019-7/8 [4-pole]
Curve charts and technical data
H H
[m] [ft]
140 KP 6019-7/8
440 60 Hz, n = 1780 rpm
/19.0
400
120
/18.0
360
/17.0
100
320
/16.0
280
80
/15.0
240
60 200
NPSH
[ft] [m]
160 80
40 20
120 60
15
80 40
20 10
40 20
5
NPSH
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
400 80
150 /16.0 30
100
/15.0
100 20
50
50 10
0 0 0
0 400 800 1200 1600 2000 2400 2800 Q [US GPM]
38
PACO KP, KPV
7
KP 6020-3/4 [4-pole]
360
/17.0
100
320
/15.5
280
80
240 /14.0
60 200
160
NPSH
[ft] [m]
40
120 60
15
80 40
20 NPSH 10
40 20
5
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
800 80
500 700 70
/20.0
/17.0 /18.5
600 /15.5 60
/14.0
400
500 /20.0 50
300 /17.0 30
200
/15.5
200 20
/14.0
100
100 10
0 0 0
TM05 5026 3212
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
TM05 5026 3912
39
7 PACO KP, KPV
KP 8012-5/6 [4-pole]
Curve charts and technical data
H H
[m] [ft]
170 KP 8012-5/6
50 /12.0 60 Hz, n = 1780 rpm
160
150
45
140
/10.8
40 130
120
35
110
/9.5
30 100
90
25 /8.25
80
70
20
60
/7.0
50
NPSH
15
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
NPSH 4
10 10
2
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
90
120 160 /12.0 80
/10.8
100 140 70
/9.5
/8.25
120 /12.0 60
80 /7.0
100 50
/10.8
60 80 40
60 30
40 /9.5
40 /8.25 20
20
20 /7.0 10
0 0 0
TM05 5027 3212
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
TM05 5027 3912
40
PACO KP, KPV
7
KP 8015-3/4 [4-pole]
180
50 /12.0
160
140
40 /10.5
120
30 100 /9.0
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 NPSH 20
5
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
450 90
300 400 80
/13.5 /15.0
250 350 /12.0 70
/10.5
300 /15.0 60
200 /9.0
250 50
/13.5
150 200 40
150 /12.0 30
100
100 /10.5 20
50
50 /9.0 10
0 0 0
TM05 5028 3212
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Q [US GPM]
TM05 5028 3912
41
7 PACO KP, KPV
KP 8020-5/6 [4-pole]
Curve charts and technical data
H H
[m] [ft]
440
/19.25 KP 8020-5/6
130
420 60 Hz, n = 1780 rpm
400
120
380
/17.94
110 360
340
100
320 /16.62
90 300
280
/15.31
80 260
240
70 /14.0
220
60 200
180
50 160
140
40
120
NPSH
30 100 [ft] [m]
80 80
20 20
60 60
15
40 40
10 10
20 NPSH 20 5
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
1800 90
1200 1600 80
/19.25
/16.62 /17.94
1000 1400 /15.31 70
/14.0
1200 60
800
1000 50
600 800 40
/19.25
600 /17.94 30
400
/16.62
400 20
/15.31
200 /14.0
200 10
0 0 0
TM05 5029 3212
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
TM05 5029 3912
42
PACO KP, KPV
7
KP 1012-1/2 [4-pole]
150
45
140
/11.07
40 130
120
35
110 /10.15
30 100
/9.23
90
25
80
/8.3
70
20
60
15 50
40
NPSH
[ft] [m]
10
30 60
15
20 40
5 10
10 NPSH 20 5
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
360 90
240 320 80
200 280 70
/10.15 /11.07 /12.0
/9.23
240 60
160
200 /8.3 50
0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 Q [US GPM]
TM05 5030 3912
43
7 PACO KP, KPV
KP 1015-3/4 [4-pole]
Curve charts and technical data
H H
[m] [ft]
280
KP 1015-3/4
60 Hz, n = 1780 rpm
/15.37
80 260
240
70
/14.18
220
200
60
/13.0
180
50
160 /12.0
140
40 /11.0
120
30 100
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 NPSH 20
5
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
/15.37
700 /14.18 70
500 /13.0
/12.0
600 60
400 /11.0
500 50
300 /15.37
400 40
300 /14.18 30
200
200 /13.0 20
100 /12.0
100 /11.0 10
0 0 0
TM05 5031 3212
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
TM05 5031 3912
44
PACO KP, KPV
7
KP 1020-3/4 [4-pole]
400
120
/18.25
360
100 /16.75
320
280
/15.4 NPSH
80 [ft] [m]
240 120
/14.0 35
60 200 100 30
160 80 25
40 20
120 60
15
80 40
20 10
NPSH
40 20
5
0 0 0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
1600 90
1000 1400 80
/18.25 /19.6
/15.4 /16.75
1200 70
800 /14.0
1000 /19.6 60
600 800 50
/18.25
600 /16.75 40
400
/15.4
400 30
/14.0
200
200 20
0 0 10
TM05 5032 3212
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Q [US GPM]
TM05 5032 3912
45
7 PACO KP, KPV
KP 1024-3/4 [4-pole]
Curve charts and technical data
H H
[m] [ft]
750
/24.8 KP 1024-3/4
220 60 Hz, n = 1780 rpm
700
200 650
/23.0
600
180
550
160 /21.0
500
140
450
/19.0
120 400
350 /17.0
100
300
80
250 NPSH
[ft] [m]
60 200 80
20
150 60
40 15
100 40
10
20
50 NPSH 20
5
0 0 0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
3600 90
2400 3200 80
2000 2800 70
/23.0 /24.8
/19.0 /21.0
2400 /17.0 60
1600
2000 /24.8 50
1200 1600 40
/23.0
1200 30
800 /21.0
800 /19.0 20
400 /17.0
400 10
0 0 0
TM05 5033 3212
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]
TM05 5033 3912
46
PACO KP, KPV
7
KP 1415-1/2 [4-pole]
/14.75
240
70
220
/13.75
60 200
/13.0
180
50 /12.0
160
140
40
120
30 100 NPSH
[ft] [m]
80 80
20 20
60 60
15
40 40
NPSH
10 10
20 20
5
0 0 0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
700 70
500 /14.75 /15.6
600 /12.0 /13.0 /13.75 60
400
500 50
300 400 40
/15.6
/14.75
300 30
200 /13.75
/13.0
200 /12.0 20
100
100 10
0 0 0
TM05 5034 3212
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 Q [US GPM]
TM05 5034 3912
47
7 PACO KP, KPV
KP 6019-7/8 [6-pole]
Curve charts and technical data
H H
[m] [ft]
190 KP 6019-7/8
/19.0
55 180 60 Hz, n = 1180 rpm
170
/18.0
50
160
150 /17.0
45
140
40 /16.0
130
120
35 /15.0
110
30 100
90
25 80
70
20
60
NPSH
15 50
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
160 80
100 140 70
/18.0 /19.0
/15.0 /16.0 /17.0
120 60
80
100 50
60 80 /19.0 40
/18.0
60 /17.0 30
40
/16.0
40 20
/15.0
20
20 10
0 0 0
TM05 5035 3212
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
TM05 5035 3912
48
PACO KP, KPV
7
KP 6020-3/4 [6-pole]
200
60
/18.5
180
50
160
/17.0
140
40 /15.5
120
/14.0
30 100
80
NPSH
20
[ft] [m]
60 30
8
40 20 6
10
NPSH 4
20 10
2
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
P2 P2 Eff
kW] [hp] [%]
320 80
00 280 70
/20.0
/17.0 /18.5
240 /15.5 60
/14.0
60
200 50
20 160 40
/20.0
120 /18.5 30
80
80 /17.0 20
/15.5
40 /14.0
40 10
0 0 0
TM05 5036 3212
TM05 5036 3912
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
49
7 PACO KP, KPV
KP 8015-3/4 [6-pole]
Curve charts and technical data
H H
[m] [ft]
KP 8015-3/4
120
60 Hz, n = 1180 rpm
35 /15.0
110
100
30
/13.5
90
25
80
70 /12.0
20
60
/10.5
15 50 NPSH
[ft] [m]
/9.0
40 20 6
10
30 15
4
20 10
5
2
NPSH
10 5
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
180 90
120 160 80
/13.5 /15.0
100 140 /12.0 70
/10.5
120 60
80 /9.0
100 50
/15.0
60 80 40
60 /13.5 30
40
40 /12.0 20
20 /10.5
20 /9.0 10
0 0 0
TM05 5037 3212
0 400 800 1200 1600 2000 2400 2800 3200 3600 Q [US GPM]
TM05 5037 3912
50
PACO KP, KPV
7
KP 8020-5/6 [6-pole]
180
50 /17.94
160
140 /16.62
40
120 /15.31
100 /14.0
30
80
NPSH
20
[ft] [m]
60 30
8
40 20 6
10
4
20 10
NPSH 2
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
400 90
250 350 80
/19.25
/16.62 /17.94
300 /15.31 70
200 /14.0
250 60
0 0 10
TM05 5038 3212
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
TM05 5038 3912
51
7 PACO KP, KPV
KP 1012-1/2 [6-pole]
Curve charts and technical data
H H
[m] [ft]
75
KP 1012-1/2
22 60 Hz, n = 1180 rpm
/12.0
70
20 65
60 /11.07
18
55
16
50
/10.15
14
45
/9.23
12 40
35
10 /8.3
30 NPSH
[ft] [m]
8
25 25
7
6 20 20 6
5
15 15
4 4
10 10 3
NPSH
2 2
5 5
1
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
90 90
60 80 80
30 /10.15 30
20
20 /9.23 20
10 /8.3
10 10
0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Q [US GPM]
TM05 5039 3912
52
PACO KP, KPV
7
KP 1015-3/4 [6-pole]
100 /14.0
30
90
25 /13.0
80
70 /12.0
20
60 /11.0
15 50
40
NPSH
[ft] [m]
10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
360 90
240 320 80
/15.37
280 /14.0 70
200 /13.0
/12.0
240 60
160 /11.0
200 50
120 160 40
120 /15.37 30
80
/14.0
80 20
40 /13.0
40 /12.0 10
/11.0
0 0 0
TM05 5040 3212
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
TM05 5040 3912
53
7 PACO KP, KPV
KP 1020-3/4 [6-pole]
Curve charts and technical data
H H
[m] [ft]
KP 1020-3/4
200 60 Hz, n = 1180 rpm
60 /19.6
180
/18.25
50
160
140 /16.75
40
120 /15.4
30 100 /14.0
80
NPSH
20
[ft] [m]
60 60
15
40 40
10 10
20 20
5
NPSH
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
400 90
250 350 80
/18.25 /19.6
/15.4 /16.75
300 70
/19.6
200 /14.0
250 60
/18.25
150 200 50
/16.75
150 40
100 /15.4
100 /14.0 30
50
50 20
0 0 10
TM05 5041 3212
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
TM05 5041 3912
54
PACO KP, KPV
7
KP 1024-3/4 [6-pole]
300
90
/23.0
280
80 260
240
/21.0
70
220
60 200
/19.0
180
50
160
/17.0
140
40
120
30 100
80
NPSH
[ft] [m]
20
60 30
8
40 20 6
10
4
20 NPSH 10
2
0 0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
500 700 70
/23.0 /24.8
/19.0 /21.0
600 /17.0 /24.8 60
400
500 50
/23.0
300 400 40
/21.0
300 30
200
/19.0
200 20
100 /17.0
100 10
0 0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 Q [US GPM]
TM05 5042 3912
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m³/h]
55
7 PACO KP, KPV
KP 1220-5/6 [6-pole]
Curve charts and technical data
H H
[m] [ft]
70 KP 1220-5/6
220 60 Hz, n = 1180 rpm
/20.0
200
60
180
/18.25
50
160
140 /16.5
40
120
/14.75
30 100
/13.0
80
NPSH
20
[ft] [m]
60 60
15
40 40
10 10
20 NPSH 20
5
0 0 0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
500 700 70
/16.5 /18.25 /20.0
600 /14.75 60
/13.0
400
500 50
300 /20.0
400 40
300 /18.25 30
200
200 /16.5 20
100 /14.75
100 /13.0 10
0 0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]
TM05 5043 3912
56
PACO KP, KPV
7
KP 1415-1/2 [6-pole]
100
30
/13.75
90
25 /13.0
80
/12.0
70
20
60
15 50
40
NPSH
[ft] [m]
10
30 60
15
20 40
5 10
10 NPSH 20
5
0 0 0 0
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
P2 P2 Eff
[kW] [hp] [%]
200 90
140
180 80
120 160 70
/12.0 /14.75 /15.6
/13.0
140 /13.75 60
100
120 50
80 /15.6
100 40
/14.75
60 80 /13.75 30
/13.0
60 20
40 /12.0
40 10
20
20 0
TM05 5044 3212
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
TM05 5044 3912
57
8 PACO KP, KPV
Dimensional sketch
58
PACO KP, KPV
8
Dimensional sketch
59
© Copyright Grundfos Holding A/S
The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.
98432075 0413