Product Range
Quality without Compromise
TAPCON® 240/260

State of the art voltage regulation The device even includes:


• “TAPCONtrol System” software for
Standard delivery in 19'' rack. parameterization and visualization
Also available as option: • Short-term memory for up to 1.000
• Panel mounting values (memory submodule as
• Flush mounting option).
TAPCON® 230 • Installation in ED (Motor-drive) • Measuring transducer (option)
• 1/2 19'' rack (2 regulators per rack possible) • Interfaces with several protocols to
TAPCON ® 230 for flush or projected Protocol IEC 61850 available! the SCADA system
panel mounting With TAPCON® 240/260, you can control • Free programmable in- and outputs
up to 16 transformers in parallel without any
• Excellent reliability and long liftetime extra device. Also the integration of the line
operation circuit breaker is possible. The large LCD with
• Parallel control for up to 8 transformers graphic capabilities makes commissioning
(without additional parallel control device) very easy.
• easy commissioning, supported by the
NORMSET-function
• parameterization and visualization with the
“TAPCONtrol System” software
• Measuring value function: Announcement
of one measuring value in the bottom
display row.
• Manual operation Raise / Lower directly at
the device
• Simple, logical menue guidance

TAPGUARD™ 240

Lowering costs through optimized main- principal fields of application are


tenance and preservation of your operational high- and medium-performance net-
equipment – one of your best strategies for work transformers.
better leverage against the competition! And TAPGUARD™ 240 computes the
with its new and innovated TAPGUARD™ 240, most significant maintenance criteria
MR now offers you an attractive system of the on-load tap-changer. It indi-
solution to help! cates the current status and shows
This device was developed specifically for the time interval until the next
the maintenance and upkeep of OILTAP® on- maintenance is due.
load tap-changers (switching in oil). The
VACUTAP ® VRC 400/550/700 VACUTAP ® VV
and VRE 700
The VACUTAP® VRC type is now a real alter- The on-load tap-changer VACUTAP® V V
native to the OILTAP® M type. It is mainte- operates throughout the world. With its
nance-free up to 150,000 operations for vacuum interrupters it serves for setting the
more or less all network applications. Thus ratio of oil-filled transformers under load.
your transformer life-cycle costs are reduced The VACUTAP® V V is maintenance-free
significantly. The MR vacuum switching up to 150,000 operations for more or less all
technology is proven since the 80ies. No oil network applications. Thus your transformer
A perfect couple: carbonisation and no arcing in the insulating life-cycle costs are reduced significantly.
VACUTAP® VV installed oil means no contact change and an extend-
in transformer ed lifespan of the insulating oil.
In addition, you will benefit from extend-
ed applications for auto- and HVDC trans-
formers as also for regulation at beginning of
the delta winding. Max. rated through-current: 250…600A
Max. rated step voltage: 2,000V
Max. rated through-current: 400…700A Max. rated switching capacity: 700kVA
Max. rated step voltage: 4,000V Highest voltage for
Max. rated switching capacity: 2,800kVA equipment Um: 145kV
Highest voltage for Application: Star point (neutral point)
equipment Um: 300kV for Um = 76kV or randomly selectable
Operating positions: winding position up to Um = 145kV
Without change-over selector: 18 max. Operating positions:
With change-over selector: 35 max. Without change-over selector: 12 max.
With multiple coarse selector: 107 max. With change-over selector: 23 max.
VACUTAP® AVT VACUTAP ® VT VACUTAP® RMV-II

The on-load tap-changer VACUTAP® AVT The on-load tap-changer VACUTAP® VT with Our first reactance on-load tap changer with
with vacuum interrupters and integrated vacuum interrupters serves for setting the vacuum interrupters and the most impressive
motor drive serves as switching element and ratio of dry-type transformers under load. performance history since its introduction in
for setting the ratio of dry-type transformers 1990. Area of application: primarily the
under load. North American continent.

Max. rated through-current: 150A Max. rated through-current: Max. rated through-current: 1,500…2,500A
Max. rated step voltage: 500V (3-phase) 500A Max. rated step voltage: 2,000V
Max. rated switching capacity: 75kVA Max. rated step voltage: 900V Highest voltage for
Highest voltage for Max. rated switching capacity: equipment Um: 69kV
equipment Um: 11,5kV (single-phase) 250kVA Application: At any randomly selectable
Application: Star point (neutral point) Highest voltage for winding position up to = 69kV
or randomly selectable winding position equipment Um: 40,5kV Operating positions:
up to = 11.5kV Application: Random winding position Without change-over selector: 17
Operating positions: (linear) 9 max. Operating positions: (linear) 9 max. With change-over selector: 33
OILTAP® V OILTAP® MS OILTAP® M

An exceptionally compact on-load tap- A 300A on-load tap-changer for tapped The on-load tap-changer allowing the widest
changer for tapped transformers yielding transformers yielding medium output rates. and most comprehensive scope of applica-
small to medium output rates. tions: From transformers yielding medium
output rates to large power transformers,
process transformers subject to the highest
levels of stress, special transformers...

Max. rated through-current:


(3-phase) 350…600A
(single-phase) 350…1,500A
Max. rated step voltage: 3,300V
Max. rated switching capacity:
(single-phase) 3,500kVA
Max. rated through-current: 200…350A Max. rated through-current: 300A Highest voltage for
Max. rated step voltage: 1,500V Max. rated step voltage: 3,300V equipment Um: 300kV
Max. rated switching capacity: 525kVA Max. rated switching capacity: 1,000 kVA Application up to 600A (3-phase):
Highest voltage for Highest voltage for Star point (neutral point) (Um = 245kV)
equipment Um: 123kV equipment Um: 245kV Application up to 1,500A (single-phase):
Application of the 3-phase design: Star point Application: Star point (neutral point) At any randomly selectable winding position
(neutral point) or randomly selectable winding Single-phase design at any randomly up to Um = 300 kV
position selectable winding position Operating positions:
Operating positions: Operating positions: Without change-over selector: 18 max.
Without change-over selector: 14 max. Without change-over selector: 14 max. With change-over selector: 35 max.
With change-over selector: 27 max. With change-over selector: 27 max. With multiple coarse selector: 107 max.
OILTAP® RM OILTAP® R OILTAP® G

The OILTAP® RM on-load tap-changer is The on-load tap-changer for the highest The on-load tap-changer for power trans-
composed of the R diverter switch and the voltages and transformer output rates. formers with highest capacities.
M tap selector.

Max. rated through-current: Max. rated through-current:


(3-phase) 600A (3-phase) 1,200A Max. rated through-
(single-phase) 600…1,500A (single-phase) 3,000A current: (3-phase) 1,600A
Max. rated step voltage: 4,000V Max. rated step voltage: 4,000V (single-phase) 1,600…3,000A
Max. rated switching capacity: Max. rated switching capacity: Max. rated step voltage: 5,000V
(single-phase) 4,280kVA (single-phase) 6,000kVA Max. rated switching
Highest voltage for Highest voltage for capacity: (single-phase) 6,500kVA
equipment Um: 300kV equipment Um: 362kV Highest voltage for
Application up to 600A (3-phase): Application up to 1,200 A (3-phase): equipment Um: 362kV
Star point (neutral point) (Um = 245 kV) Star point (neutral point) (Um = 245kV) Application up to 1,600A: Star point
Application up to 1,500A (single-phase): Application up to 3.600 A (single-phase): (neutral point) (Um = 245kV)
At any randomly selectable winding position At any randomly selectable winding Application up to 3,000A: At any randomly
(Um = 300kV) position (Um = 362kV) selectable winding position (Um = 362kV)
Operating positions: Operating positions: Operating positions:
Without change-over selector: 18 max. Without change-over selector: 18 max. Without change-over selector: 18 max.
With change-over selector: 35 max. With change-over selector: 35 max. With change-over selector: 35 max.
DEETAP® U

Off-circuit tap-changers (OCTC) are used for


voltage adjustment in oil-immersed trans-
formers. In contrast to on-load tap-changers,
off-circuit tap-changers require setting of
the desired winding tap while the trans-
former is deenergized.

2)

Oil Filter Unit OF100 Motor Drive ED

• paper filter design to clean the The motor drive type ED is used exclusively 3)
switching oil for operating on-load tap-changers and off-
• 2 pump unit designs available circuit tap-changers in regulating transform-
• combination filter design to clean ers as well as for operating plunger-core
and dry the switching oil earth-fault neutralizers.
• 2 designs for controlling the 1) 4)
pump unit: The ED motor drive
– control integrated into separate • has a transparent and modular design
control cabinet (swing frame)
– control integrated into the ED • is innovative: variants with electronic con- 1) Mechanical Filling Level Indicators
motor drive trol in connection with tap changer moni- 2) Mechanical Pointer Thermometers
toring (TM100) or voltage regulator 3) Sensors/Transmitters
TAPCON® 240 inside Indicators/Converters
• incorporates decades of experience 4) Pressure Relief Devices
• is available in two protective housing sizes
with the same arrangement of attachment
points
– alluminum cast
– IP 66
© Maschinenfabrik Reinhausen GmbH Phone (+49) 9 41/40 90-0
www.reinhausen.com Falkensteinstrasse 8 Fax (+49) 9 41/40 90-600
93059 Regensburg, Germany E-Mail sales@reinhausen.com

Please note: The data in our publications may differ from the data of devices delivered.
We reserve the right to make changes without notice.