Sei sulla pagina 1di 2

1. Loss that occurs in magnetic core of a transformer is copper loss. iron loss. stray loss.

dielectric loss.
2. . A Circuit of zero lagging power factor behaves as: a) An inductive circuit b) A capacitive
circuit c) R-L circuit d) R-C circuit
3. Which among the following happens in a low power factor? a. Large kVA rating of the
equipment. b. Greater conductor size. c. Reduced handling capacity of the system. d. All of the
above.
4. What is the main disadvantage of phase advancers? a. Cannot be used for motors below 200
H.P b. Produces noise. c. Can be used where synchronous motor is un admissible. d. None of
these
5. Q6. The most suitable location for the power factor improvement device is a. Near the
electrical appliance which is responsible for the poor power factor. b. At the sending end. c. At
the receiving end in case of transmission lines. d. Both (a) and (c).
6. Under what condition is D.C supply applied safely to the primary of a transformer? We can
connect directly to DC. No condition required We can’t connect to DC Supply A High resistance
should be connect in series with primary, but circuit will be useless. The above statement is wron
7. When the power factor in the transmission line is leading, which device is employed at
substation to reduce the power factor: a) CVT b) Reactor c) Synchronous condenser d) None of
the above
8. In a Transformer , The primary flux is always _________ the secondary ( flux). Greater then
Smaller then Equal Equal in both step up and Step down Transformer
9. Breaking capacity of a circuit breaker is usually expressed in terms of(A) Amperes(B) Volts(C)
MW (D) MVA
10. The fuse current in amperes is related with fuse wire diameter D as(A) I ∞ I/D(B) I ∞ D(C) I ∞
D3/2 (D) I ∞ D2.
11. For motor circuit breakers, the time of closing the cycle is(A) 0.001 sec(B) 0.01 sec(C) 0.10
sec(D) 0.003 sec.
12. In modem EHV circuit breakers, the operating time between instant of receiving trip signal
and final contact separation is, of the order of(A) 0.001 sec(B) 0.015 sec(C) 0.003 sec (D) 0.03
sec.
13. The normal frequency rms voltage that appears across the breaker poles after final arc
extinction has occurred, is(A) recovery voltage(B) re striking voltage(C) supply voltage (D) peak
voltage.
14. For motor circuit breakers, the time of closing the cycle is(A) 0.001 sec(B) 0.01 sec(C) 0.10
sec (D) 0.003 sec. Fuse protection is used for current ratings up to(A) 10 A(B) 20 A(C) 50 A (D)
100 A
15. The number of cycles in which a high speed circuit breaker can complete its operation is (A)
3 to 8(B) 10 to 18(C) 20 to 30 (D) 40 to 50.
16. In a circuit breaker the current which exists at the instant of contact separation is known as
(A) re striking current (B) surge current (C) breaking current (D) recovery current.
17. Breaking capacity of a circuit breaker is usually expressed in terms of (A) Amperes (B) Volts
(C) MW (D) MVA.
18. For a high speed circuit breaker the total clearing time is nearly(A) 1 to 2 cycles(B) 5 to 10
cycles(C) 10 to 15 cycles (D) Less than 50 cycles
19. The most common method of cooling employed in power transformer is:a) Oil naturalb)
Natural coolingc) Air cooling d) Air-blast cooling
20. The value of flux in the emf equation of a transformer is (a) rms (b) Average
(c) Maximum (d) Integral wave cycle
21. In Three Phase Transformer, The load Current is 139.1A, and Secondary Voltage is 415V.
The Rating of the Transformer would be __________ (a).50kVA (b).57.72kVA (c).100kVA
(d)173kVA
22. The friction losses in Real Transformers are _________? 0% 5% 25% 50%
23. Power factor = actual /apparent power
24. If a conductor is passing through a metallic case with ground potential which kind of
protection is provided.
25. TO reduce cost we must Increase KVA
26. KVAR is equal to
27. Power factor of Alternator
28. Power factor of transformer
29. KVA numerical
30. Transformer numerical (2)
31. CB numerical 2
32. Sound of transformer
33. CB without resistance
34. The modern circuit breakers have the operation completed in how many cycles.
35. Which winding will have smaller cross sectional area?
36. Admittance is ?
37. The Resitance between primary and secondry of transformer should be Infinite
38. The voltage at no load Leads the Current by 90 degree
39. Voltage lags behind the current when load is connected to the transformer by what degrees?
40. Laminations are done to reduce the eddy current losses
41. One question related to iron losses.

Potrebbero piacerti anche