Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Providing and laying Vitrified tiles in different sizes, with water absorption
less than 0.08% and conforming to IS: 15622, of approved brand and
manufacturer in all colours and shade in skirting, riser of steps, laid with
11.56 Sqm
cement based high polymer modified quick set tile adhesive (water
based) conforming to IS: 15477, in average 6 mm thickness, including
grouting of joints (Payment for grouting of joints to be made separately).
Grouting the joints of flooring /skirting, risers of step of vitrified tiles
having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic
11.57 coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin Sqm
per kg), including filling/ grouting and finishing complete as per direction
of Engineer- in-charge.
Toilets Sunken
Providing and laying integral cement based water proofing treatment
23 including preparation of surface as required for treatment of roofs,
balconies, terraces etc consisting of following operations:
Page 1 of 30
Abstract Of Cost
Construction of Administrative/IT/ITES complex adjoining crystal IT Park,Khandwa ro
Name of HVAC,Electrical, lift Plumbing, fire fighting,landscape,STP,BMS, outer development e
work:- property management(Opretaion & maintenance)
Agency:- M/s Kunal Structure (I) Pvt. Ltd.
Agr. Item
Description of Item Unit
No.
c) After two days of proper curing applying a second coat of cement
slurry using 2.75kg/ sqm of cement admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge.
d) Finishing the surface with 20 mm thick jointless cement mortar of mix
1:4 (1 cement :4 sand) admixed with water proofing compound
conforming to IS : 2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of plaster and
finally finishing the surface with trowel with neat cement slurry and
making pattern of 300x300 mm square 3mm deep.
e) The whole terrace so finished shall be flooded with water for a
minimum period of two weeks for curing and for final test. All above
operations to be done in order and as directed and specified by the
Engineer-in-Charge : (with 5 years service guarantee)
With average thickness of 120mm and minimum thickness at khurra as
22.7.1 Sqm
65 mm.
MS Steel works
10 Steel work in built up tubular ( round, square or rectangular hollow tubes
etc.) trusses/frame work etc. including cutting, hoisting, fixing in position
and applying a priming coat of approved steel primer, including welding
and bolted with special shaped washers etc. complete.
Sub Total
Page 2 of 30
Abstract Of Cost
Construction of Administrative/IT/ITES complex adjoining crystal IT Park,Khandwa ro
Name of HVAC,Electrical, lift Plumbing, fire fighting,landscape,STP,BMS, outer development e
work:- property management(Opretaion & maintenance)
Agency:- M/s Kunal Structure (I) Pvt. Ltd.
Agr. Item
Description of Item Unit
No.
Total-
Page 3 of 30
Cost Date 10.08.18.
x adjoining crystal IT Park,Khandwa road Indore i/c all allied works like
dscape,STP,BMS, outer development etc, including 3years integrated
ce)
Page 4 of 30
Cost Date 10.08.18.
x adjoining crystal IT Park,Khandwa road Indore i/c all allied works like
dscape,STP,BMS, outer development etc, including 3years integrated
ce)
(783,653.50)
15,300.00 1 15,300.00
16,120.00 9 145,080.00
1,584,695.00 1 1,584,695.00
10,596,792
Above 14% 1,483,550.87
Page 5 of 30
Cost Date 10.08.18.
x adjoining crystal IT Park,Khandwa road Indore i/c all allied works like
dscape,STP,BMS, outer development etc, including 3years integrated
ce)
12,080,343
Page 6 of 30
Date of measurement : 05.01.2018.
Item No. Description of Item No Length Width Height Quantity Unit
Providing and laying integral cement based water proofing treatment including
23 preparation of surface as required for treatment of roofs, balconies, terraces etc
consisting of following operations:
a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with
water proofing compound conforming to IS. 2645 and approved by Engineer-in-
charge over the RCC slab including adjoining walls upto 300mm height including
cleaning the surface before treatment.
b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size
with 50% of cement mortar 1:5 (1 cement : 5 sand) admixed with water proofing
compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm
thick layer of cement mortar of mix 1:5 (1 cement
:5 sand ) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and treating similarly the adjoining
walls upto 300 mm height including rounding of junctions of walls and slabs
c) After two days of proper curing applying a second coat of cement slurry using
2.75kg/ sqm of cement admixed with water proofing compound conforming to IS :
2645 and approved by Engineer-in-charge.
d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1
cement :4 sand) admixed with water proofing compound conforming to IS : 2645 and
approved by Engineer-in-charge including laying glass fibre cloth of approved quality
in top layer of plaster and finally finishing the surface with trowel with neat cement
slurry and making pattern of 300x300 mm square 3mm deep.
e) The whole terrace so finished shall be flooded with water for a minimum period of
two weeks for curing and for final test. All above operations to be done in order and
as directed and specified by the Engineer-in-Charge : (with 5 years service
guarantee)
22.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm.
Podium Floor, (Toilet Sunken filling)
9
Angle 50x50x5 @3.8 kg per meter 42 0.85
Angle 50x50x5 @3.8 kg per meter 56 0.60
Checkered Plate
Checkered Plate 14 0.85 0.25 0.010
Sub Total
Stair5 at podium
Angle 65x65x5 @4.9 kg per meter 2 5.05
Post Pipe 150X150X4 2 1.90
Horizontal Pipe 150X150X4 1 1.75
MS Plate 1 0.15 0.25 0.008
Bolt 12mm 20
Angle 50x50x5 @3.8 kg per meter 31 1.77
Angle 50x50x5 @3.8 kg per meter 28 0.60
Checkered Plate 1 2.07 1.77 0.010
Checkered Plate 8 1.77 0.25 0.010
Sub Total
Catwalk (4.5mx0.8m)
MS Plate (200x500) 6 0.10 0.01
Anchor bar 8mm @0.395 kg per meter 12 0.80
MS bracket Angle 75x75x5 @5.7 kg per meter 6 0.80
bracing 1 Angle 75x75x5 @5.7 kg per meter 6 0.59
bracing 2 Angle 75x75x5 @5.7 kg per meter 6 0.89
Flat 50x5 @1.96 kg per meter 45 0.80
Angle 75x75x5 4 4.50
Sub Total
For 1 Square Meter 4.5 0.80 3.60
10
Cut Covering
Angle 130X130X8mm @15.9kg/m 2 1.80
Angle 130X130X8mm @15.9kg/m 5 1.18
Anchor Bolt 10mm 24
Checkered Plate 1 1.80 1.44 0.008
Sub Total
DG Room Shade
MS Plate 14 0.30 0.20 0.008
Bolt 12mm 56
ISMC 250 @30.6 kg/m 4 12.65
ISMC 100 @9.56 kg/m 3 12.40
Sub Total
MS Platform
Plumbing Shaft 1
MS Plate (20x500) 5 0.10 0.01
Anchor bar 8mm 10 0.80
MS bracket Angle 75x75x5 3 0.90
Flat 50x5 9 0.80
ISMB 250 1 3.30
Sub Total
Plumbing Shaft 2
MS Plate (20x500) 5 0.10 0.01
Anchor bar 8mm 10 0.80
MS bracket Angle 75x75x5 3 0.90
Flat 50x5 9 0.80
ISMB 250 1 3.35
Sub Total
Plumbing Shaft 3
11
MS Plate (20x500) 5 0.10 0.01
Anchor bar 8mm 10 0.80
MS bracket Angle 75x75x5 3 0.90
Flat 50x5 9 0.80
ISMB 250 1 4.15
Sub Total
Total
Net Payble Qt
12
Unit wt. Quantity Unit
4.900 26.46 kg
7850 2.36 kg
0.15 3.30 kg
3.800 101.08 kg
3.800 63.84 kg
7850 55.93 kg
7850 111.86 kg
Sub Total 364.83 kg
4.900 31.85 kg
7850 0.00 kg
0.15 3.90 kg
3.800 90.44 kg
3.800 63.84 kg
7850 63.39 kg
7850 100.09 kg
Sub Total 353.51 kg
4.900 44.59 kg
7850 1.41 kg
7850 2.83 kg
0.15 5.10 kg
3.800 135.66 kg
3.800 127.68 kg
7850 0.00 kg
7850 233.54 kg
Sub Total 550.81 kg
4.900 44.59 kg
7850 2.36 kg
7850 2.83 kg
0.15 5.10 kg
13
3.800 135.66 kg
3.800 127.68 kg
7850 0.00 kg
7850 233.54 kg
Sub Total 551.75 kg
4.900 49.49 kg
18.01 68.44 kg
18.01 31.52 kg
7850 2.36 kg
0.15 3.00 kg
3.80 208.51 kg
3.80 63.84 kg
7850 287.62 kg
7850 277.89 kg
Sub Total 992.65 kg
7850 47.10 kg
0.395 3.79 kg
5.700 27.36 kg
5.700 20.11 kg
5.700 30.57 kg
1.960 70.56 kg
5.700 102.60 kg
Sub Total 302.10 kg
83.92 kg
83.92 5545.15 kg
83.92 3980.96 kg
83.92 3550.64 kg
83.92 3560.04 kg
83.92 2282.51 kg
83.92 2282.51 kg
Sub Total 21285.71 kg
14
15.90 57.24 kg
15.90 93.81 kg
0.125 3.00 kg
7850 162.78 kg
Sub Total 316.83 kg
7850 52.75 kg
0.70 39.20 kg
37.30 1887.38 kg
104.00 3868.80 kg
5.30 134.62 kg
5.30 3.18 kg
5.30 2.12 kg
182.02 Kg
7850 3.77 Kg
542.59 Kg
728.38 Kg
25.28 Kg
25.28
50.56 Kg
7850 39.25 kg
0.395 3.16 kg
5.70 15.39 kg
1.96 14.11 kg
37.30 123.09 kg
195.00 kg
7850 39.25 kg
0.395 3.16 kg
5.70 15.39 kg
1.96 14.11 kg
37.30 124.96 kg
196.87 kg
15
7850 39.25 kg
0.395 3.16 kg
5.70 15.39 kg
1.96 14.11 kg
37.30 154.80 kg
226.71 kg
4.900 26.46 kg
7850 2.36 kg
0.15 3.30 kg
3.800 101.08 kg
3.800 63.84 kg
7850 55.93 kg
7850 111.86 kg
Sub Total 364.83 kg
4.900 31.85 kg
7850 0.00 kg
0.15 3.90 kg
3.800 90.44 kg
3.800 63.84 kg
7850 63.39 kg
7850 100.09 kg
Sub Total 353.51 kg
4.900 44.59 kg
7850 1.41 kg
7850 2.83 kg
0.15 5.10 kg
3.800 135.66 kg
3.800 127.68 kg
7850 0.00 kg
7850 233.54 kg
Sub Total 550.81 kg
Total 33372.88 kg
16
Date of measurement : 18.2.2018.
A :-
17
Verticle pipe 5
5
5
Horizontal pipe 2
2
8
10
B :-
Verticle pipe 6
6
3
6
6
Horizontal pipe 2
18
17
2
17
17
2
C :-
Verticle pipe 11
1
9
2
1
2
4
4
Horizontal pipe 1
13
13
3
10
1
10
7
2
1
2
7
2
10
D :-
Verticle pipe 2
2
5
18
Horizontal pipe 2
17
2
20
TOTAL
Ms Tubular Pipe Section (80x40x4mm) @
1565.72 6.71
6.71kg/Meter
6 MS Railing
Stilt Floor
MS Pipe 49.5X49.5X2.9mm @4.07 kg/m 64.0 0.65
MS Pipe 49.5X49.5X2.9mm @4.07 kg/m 36.0 1.10
TOTAL
Podium
MS Pipe 49.5X49.5X2.9mm @4.07 kg/m 11.0 1.10
MS Pipe 49.5X49.5X2.9mm @4.07 kg/m 20.0 0.65
TOTAL
North Elevation fabricatoin for ACP
7
Verticle pipe 8
44
40
Bracing @ 1m c/c 29 0.6
20 0.6
19 0.6
19
D/H Quantity Unit
1.00 236.00 m
7.01 4963.08 kg
TOTAL 4963.08 Kg
51.1 Meter
3957.695 Kg
39.95
15.25
al 55.20 Meter
4275.24 Kg
6.400 39.81
9.066 8.25
5.512 44.10
50.00
6.400 125.95
9.066 49.32
5.512 286.62
150.00
al 754.05 Meter
754.05 1508.10 kg
20
3.9 19.5
4.8 24
11.37 56.85
13.95 27.9
8.05 16.1
1.98 15.84
1.93 19.3
179.49 Meter
4.35 26.1
16.15 96.9
22.65 67.95
15.15 90.9
4.9 29.4
22.69 45.38
1.78 32.04
1.97 33.49
9.75 19.5
1.98 33.66
1.98 33.66
9.94 19.88
528.86 Meter
15.15 166.65
3.8 3.8
11.4 102.6
4.9 9.8
2.68 2.68
3.9 7.8
8.1 32.4
12.38 49.52
17 17
1.94 25.22
2 26
1 3
1.96 19.6
17.15 17.15
1.94 19.4
2.05 14.35
2.95 5.9
34.12 34.12
4.21 8.42
1.7 11.9
4.21 8.42
1.7 17
602.73 Meter
15.17 30.34
4.92 9.84
22.7 113.5
21
10 20
2 34
3.48 6.96
2 40
254.64 Meter
10505.98 Kg
4.07 169.31 kg
4.07 161.17 kg
TOTAL 330.48 kg
4.07 49.25 kg
4.07 52.91 kg
4.07 4.48 kg
4.07 6.19 kg
TOTAL 112.82 kg
28.73 229.84
19.55 860.20
19.30 772.00
17.40
12.00
11.40
1902.84
7744.559 Kg
Total 33397.96 kg
22
Date of measurement : 16.2.2018.
Item No. Description of Item No Length Width Height Quantity Unit
Providing and laying Vitrified tiles in floor with different sizes, with water absorption
less than 0.08% and conforming to IS:15622 , of approved brand and manufacturer in
all colours and shade, laid with cement based high polymer modified quick set tile
11.55
adhesive (water based) conforming to IS : 15477, in average 6 mm thickness,
including grouting of joints (Payment for grouting of joints to be made separately).
Stair Case-1
Stilt Floor 1 6.8 6.80
Podium Floor 1 1.00
Set-1 1 6.3 6.30
Set-2 1 6.3 6.30
1st Floor 1 8.75 8.75
2nd Floor 1 8.75 8.75
3rd Floor 1 8.75 8.75
4th Floor 1 8.75 8.75
5th Floor 1 8.75 8.75
6th Floor 1 8.75 8.75
7th Floor 1 8.75 8.75
8th Floor 1 8.75 8.75
Stair Case-2 0.00
Stilt Floor 1 6.8 6.80
Podium Floor 0.00
Set-1 1 6.3 6.30
Set-2 1 6.3 6.30
1st Floor 1 8.75 8.75
2nd Floor 1 8.75 8.75
3rd Floor 1 8.75 8.75
4th Floor 1 8.75 8.75
5th Floor 1 8.75 8.75
6th Floor 1 8.75 8.75
7th Floor 1 8.75 8.75
8th Floor 1 8.75 8.75
Stair Case-3 0.00
Stilt Floor 1 6.6 6.60
Podium Floor 0.00
Set-1 1 6.05 6.05
Set-2 1 6.05 6.05
1st Floor 1 8.6 8.60
2nd Floor 1 8.6 8.60
3rd Floor 1 8.6 8.60
4th Floor 1 8.6 8.60
5th Floor 1 8.6 8.60
6th Floor 1 8.6 8.60
7th Floor 1 8.6 8.60
8th Floor 1 8.6 8.60
Total 267.30
At 5.5 Kg per RM 352.6 5.5 1939.30
Net payble Qty Total 1939.30
Unit Rate Qty Amount