With an 2 years experience in the field of Relay Testing and Commissioning of power
system products. I look forward for an opportunity to display my skills in the field of Relay testing
& commissioning, Execution of projects related to power systems.

Academic Profile.
2012-BE(Electrical and Electronics Engineering) PET engineering college Vallioor,(Afflicted to
Anna University Chennai)—7.3 CGPA

Skill Set.
Having an experience and knowledge in the field of Relay testing and Commissioning GIS & AIS
Substation. Power system Generation, Transmission& Distribution.

Responsibilities:
 Testing of Numerical relays Siemens (7SJ80,6MD86,7SS525, 7VK61, 7UT63,7SD61 ,
7SS52) ,MICOM (P444,C262) and Electro mechanical relays Ex JVS Relays.

 Testing and Commissioing of Auto transformer,Reactor,AVR with differential & REF


protection.

 STABLITY Test checking of Bus Bar,ICT and Reactor.

 Testing of CT,CVT,LA,WT,CB ,Isolator , Earthswitch and Switchgear equibment upto


765kV level.

 Testing the Local &Electical operation of Circuit Breaker,Isolator and Earthswitch.

 Scheme checking of HT ,LT control and Relay Panel wiring circuits,interface from yard
equibment to Control & Relay Panel with interlocks for transformer,Bus coupler & Line
bays.

 FO cable laying with the preparation of schedule in Star and Ring networks.

 For ABB make PLCC panel Analog and Digital protection end to end signal testing and
LMU ,HF cable connection testing.

 ABB make Speech Panel end to end testing.

 Testing of 220V and 48V Battery Charging and Discharging & Battery charger change
over scheme testing source 1 to 2.and 6kVA inverter commissioning.

 Commissioing of Fire fighting Jockey pump-1&2,Diesel Engine,Motor driven Pump ,


Smoke & Heat detection,Deluge & Fire system.
 DG set commissioning and auto operation verification to when power failure.DC light
change over scheme checking.

 Siemens make PSD commissioning in 400kV and 765kV in Transformer and reactor Bays.

 Troble shooting of all Electrical circuits,Control and Protection circuits.

 Modification of the cable schedule & Scheme wiring circuit as per customer and System
Requirements.

 Submission of As-build cable schedule,scheme drawing & Test reports.

 IED Configuration through IEC61850 configurator for Siemens,Alstom, and ABB relays.

 Siemens PAS Substation Automation System with integration of IEC-61850, IEC-60870-5-


104, IEC-60870-5-101, Soft PLC, SNMP, SNTP, Modbus protocol etc. Communication
establishment as per the architecture with all manufacturer IEDs (Protection and BCU),
SIEMENS RTUs, AI Units, RTCC AVR, ODS, DGA, FOS ,Ethernet Switches, Disturbance
Recorders & Energy meters.

 IEC 60870-5-104 & 101 Configurations

 HMI Configuration in Substation Automation System

 Testing and Commissioning of SCADA System

 SIMATIC WinCC - Substation Automation System with creation of dynamic graphic of


SLDs, configuration of Alarm & Events, Daily Reports & Trends configuration, Tag
management, Print layout designer for Report, Trends, Alarm & Events & System
Architectures with NMS.

Soft ware skills


 Digsi 4 (Version 4.91)
 Digsi 5 (Version 7.50)
 Sicam PAS UI Configuration (Version 8.08)
 WINCC Explorer (Version 7.03)
 SICAM230 (Version 6.50)
 Tool Box -II(Version 5.2)
 MICOM S1 AGILE(Version 1.3.1).
 Test Universe (Version 3.10)
 IEC Browser.
 PSD Control.
 SIGRA(Version 4.59).
KITS Handled.

 Omicron CMC 256,256+ Secondary Injection kit.

 Omicron CT Analyser.

 Omicron CPC100 with 2000A booster.

 Scope Timing and DCRM kit.

 Megger 6000 Primary injection kit.

 Insulation Resistance tester-Megger,KYRITSU,Fluke,Analog megger.

PRESENT EXPERIENCE

Company : ROMI TECHNOLOGY PVT LTD


Designation : Relay Testing and commissioning Engineer
Duration : From January-2017 To Till Now

Project Details:

Project Title : 765/400kV PGCIL ,WARORA


Job Responsibilities : Relay Testing and commissioning engineer.
Site Location : 765/400kV PGCIL Sub Station ,WARORA.

Project Title : 220/33kV GIS Reliance IT park,Mumbai


Job Responsibilities : Relay Testing and SCADA commissioning
Site Location : Reliance IT park , Mumbai.

PREVIOUS EXPERIENCE-I

Company : A-STAR TESTING AND INSPECTION PVT LTD


Designation : Site Supervisor
Duration : From February-2016 To December-2016
Job Responsibilities : Quality Control& Documentation
Site Location : Reliance Industries Ltd, Jam Nagar ,Gujarat.
PREVIOUS EXPERIENCE-II

Company : SEA-HUB INSPECTION AND SERVICES


Designation : Site Coordinator
Duration : From MAY-2015 To FEBRUARY-2016
Job Responsibilities : Quality Control & Documentation
PREVIOUS EXPERIENCE-III
Company : VINAYAGA CONSTRUCTIONS
Military Engineer Services
INS Kattabommam(Naval Base)
Designation : SUB-STATION OPERATER
Duration : From OCTOBER-2012 To APRIL-2015

Job Responsibilities : Substation Operating and Maintenance

Academic Project

Project Title: “Diode-Clamped three level inverter based battery/super capacitor direct
integration scheme for Renewable Energy Systems”

Achievements
 Secured 20 GATE Score during the year 2012.
 Secured Certificate in three days “National Franchisee Training Program” conducted by
Transmission and Distribution Training Institute, TANGENGO Madurai.
 Secured Certificate in “72hours-Pre-Placement Training Program” conducted by
VolTech HR Services Private Limited, Chennai.
Personal Details.
Father’s Name : Mr.S.Vaigundaraj
Mother’s Name : Mrs.V.Bavani
Date of Birth : 25.06.1991
Gender : Male
Marital Status : Single
Nationality : Indian
Languages Known : English, Hindi and Tamil
PASSPORT DETAILS.
Passport no : L6882130
Date of Expiry : 20/01/2024
Place of Issue : Madurai
Declaration
I hereby declare that all the information furnished above is true to the best of my
knowledge and belief.

SIGNATURE

(V.SATHISKUMAR)

Potrebbero piacerti anche