Report no. - CEMC/BPI/011018/WW Issued Date-01.10.2018

Name & Address of the Client : M/s Airport Authority of India, B.P.I
Airport, Bhubaneswar, Odisha
Date of Sampling : 27.09.2018
Sample Drawn By : Mahesh
Date of Sample Received : 28.09.2018
Date of Analysis : 28.09.2018 to 01.10.2018
Sample Description : Waste water
Sample Quantity : 1.0 Ltr
Location : STP Inlet Water
Reference No. : CEMC-01102018W

ANALYSIS RESULT

Sl. STP Inlet


Parameter Units Testing Method
No. water
1. pH Value @ 25oC - APHA 4500 H+ B 7.10
2. Total Suspended Solids mg/l APHA 2540 D 168.2
3. B.O.D for 3 days @ 27oC mg/l APHA 5210 B 480
4. C.O.D mg/l APHA 5220 C 1020
5. Ammonical Nitrogen as NH3-N mg/l APHA 4500NH3 B, C 18.2
6. Total Nitrogen as N mg/l APHA 4500 N, B 42.8
7. Faecal Coliform mg/l APHA 9221E 17

Authorized Signatory Seal Laboratory

Notes:
 The result given above related to the tested sample, as received. The customer asked for the above
test only.
 This Test Report shall not be reproduced wholly or in part without prior written consent of the
laboratory.
 The samples received shall be destroyed after two weeks from the date of issue of the Test Report
unless specified otherwise.
 This Test Report shall not be used in any advertising media or as evidence in the court of Law
without prior written consent of the laboratory.

Environmental Studies (EIA & EMP),Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies, RS&
GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey.
st
Regd. Office: 1 Floor, N-5/305, IRC village, Nayapalli, Bhubaneswar-751015, Odisha, India,Mobile: 9861032826
E-mail- cemc_consultancy@yahoo.co.in, cemc122@gmail.com, website: www.cemc.in, Landline: 0674-2360344.
Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101,
E-mail: cemclab@yahoo.in, Mobile: 9937631956, 8895177314
CENTRE FOR ENVOTECH AND
MANAGEMENT CONSULTANCY PVT. LTD.
An ISO 9001-2008 & OHSAS 18001:2007 Certified Company, Empanelled with OCCL, ORSAC and SPCB of Govt. of Odisha
Accredited by NABET, QCI for EIA Studies as ‘A’ Category Consultant Organization. Empanelled with PCCF(Wildlife) &CWLW,Odisha
Enlisted in Construction Industry Development Council (CIDC) established by the Planning Commission (Govt. of India)
CEMC MoEF&CC, Govt. of India, Recognised Environment Laboratory under Environment (Protection) Act, 1986.

Report no. - CEMC/BPI/011018/WW Issued Date-01.10.2018

Name & Address of the Client : M/s Airport Authority of India, B.P.I
Airport, Bhubaneswar, Odisha
Date of Sampling : 27.09.2018
Sample Drawn By : Mahesh
Date of Sample Received : 28.09.2018
Date of Analysis : 28.09.2018 to 01.10.2018
Sample Description : Waste water
Sample Quantity : 1.0 Ltr
Location : STP Outlet Water
Reference No. : CEMC-01102018W

ANALYSIS RESULT
Effluent
Sl. Discharge
Parameter Unit Testing Method Result
No. Standard
(a)
1. pH Value @ 25oC - 6.5-9.0 APHA 4500 H+ B 7.32
2. Total Suspended Solids mg/l <20 APHA 2540 D <5
3. B.O.D for 3 days @ mg/l
<10 APHA 5210 B 3.2
27oC
4. C.O.D mg/l <50 APHA 5220 C 12.4
5. Ammonical Nitrogen as
mg/l <5 APHA 4500NH3 B, C ND
NH3-N
6. Total Nitrogen as N mg/l <10 APHA 4500 N, B 2.2
7. Faecal Coliform MPN/100ml <100 APHA 9221E <1.8
N.B:- ND-Not Detected

Authorized Signatory Seal Laboratory

Notes:
 The result given above related to the tested sample, as received. The customer asked for the above
test only.
 This Test Report shall not be reproduced wholly or in part without prior written consent of the
laboratory.
 The samples received shall be destroyed after two weeks from the date of issue of the Test Report
unless specified otherwise.
 This Test Report shall not be used in any advertising media or as evidence in the court of Law
without prior written consent of the laboratory.

Environmental Studies (EIA & EMP),Monitoring, Forest Diversion Planning, DPR, Wildlife Management Plan, Hazardous & Safety Studies, RS&
GIS, Baseline Survey, Hydrological & Geological Studies, Socio-economic Studies, DGPS & ETS Survey.
st
Regd. Office: 1 Floor, N-5/305, IRC village, Nayapalli, Bhubaneswar-751015, Odisha, India,Mobile: 9861032826
E-mail- cemc_consultancy@yahoo.co.in, cemc122@gmail.com, website: www.cemc.in, Landline: 0674-2360344.
Laboratory At: Plot No. 800/1274, Johal, Pahal, Bhubaneswar-752101,
E-mail: cemclab@yahoo.in, Mobile: 9937631956, 8895177314

Potrebbero piacerti anche