Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
largest aggregate; Sandblast - using the same texturing motions • Dryvit finishes shall not be used
applied in a thickness of that are used with other plaster below grade when applied as the
1.2 mm (3/64 in) – approximately materials, such as a skip trowel finish for an EIF System.
1 1/2 times the largest finish. The thickness of any • Dryvit finishes are not intended
aggregate). The textures are Freestyle finish texture shall not for direct-applied, vertical
achieved by uniform hand exceed 6.4 mm (1/4 in). applications over exterior type
motion and/or type of tool used. gypsum based sheathing board,
Maintain wet edge for uniformity Clean Up - Clean tools with water foam plastic insulation or other
of color and texture. while the finishes are still wet. type insulation board.
• Sandpebble or Sandpebble • Dryvit finishes shall not be
Fine: roughly apply an even coat Maintenance - All Dryvit products returned into any sealant joint.
of finish to a thickness slightly are designed to require minimal Instead, a coat of Dryvit Color
thicker than the largest maintenance. However, as with all Prime or Dryvit Demandit®
aggregate size. Then pull building products, depending on should be applied over the base
across the rough application location, some cleaning may be coat in the joint.
coat using a horizontal trowel required. See Dryvit publication • Minimize exposure of materials
motion and develop a uniform DS152 on cleaning and recoating. to temperatures over 32 °C
thickness no greater than the (90 °F).
largest aggregate of the material. Storage • Finishes exposed to
The textures are achieved by Finishes must be stored at a temperatures over 43 °C
uniform hand motion and/or type minimum of 4 °C (40 °F) and a (110 °F) for even short periods
of tool used. Maintain wet edge maximum of 38 °C (100 °F) in may exhibit skinning, increased
for uniformity of color and tightly sealed containers out of viscosity, and should be
texture. direct sunlight. inspected prior to use
• Freestyle: using a stainless
steel trowel, apply a coat of the Cautions and Limitations Technical and Field Services
Freestyle slightly thicker than • Dryvit finishes must not be used Available on request.
1.6 mm (1/16 in). The texture is on exposed exterior horizontal
either pulled out of this base or surfaces. Minimum slope is
achieved by adding more 6 in 12 which is 27°. Maximum
Freestyle finish to the base layer length of slope is 305 mm (12 in).
2
DPR Finishes DS416
Dryvit Systems, Inc. Information contained in this product sheet conforms to the
P.O. Box 1014 standard detail recommendations and specifications for the
One Energy Way installation of Dryvit Systems, Inc. products as of the date of
W. Warwick, RI 02893 publication of this document and is presented in good faith.
(800) 556-7752 Dryvit Systems, Inc. assumes no liability, expressed or
www.dryvit.com implied, as to the architecture, engineering or workmanship of
any project. To ensure that you are using the latest, most
complete information, contact Dryvit Systems, Inc.