Sei sulla pagina 1di 24

Elevator Drive

Varispeed L7
Induction・PM Motor Vector Drive
200V class 3.7~55kW
400V class 3.7~55kW

Yaskawa

YASKAWA Page1
IM/PM Drive Capability IM (V/f)
IM (PG Less)
No pole sensor required. The Initial Magnetization Estimation L7
function detects the position of the magnetic pole when the IM (PG)
power is turned on. So, you do not have to reposition the PM IPM
magnetic pole after replacing the encoder. (No-
(No-pole sensor)
SPM
(No-
(No-pole sensor)

● Induction motor Machine-


● PM motor
room
machine-room

Gearモータ IPM motor


motor Control
sheave 制御盤
cabinet Control
cabinet
drive

Elevator
Counter
Counter weight
Elevator

weight

ground ground

buffer
buffer

under underg
groun round
YASKAWA d
Page2
Motor Construction

【 Construction Comparison between IPM Motor and Induction Motor 】

STATOR STATOR ROTOR STATOR


WINDING

SECONDARY
CONDUCTOR

PERMANENT
ROTOR
MAGNET STATOR
WINDING

IPM Motor Induction Motor

YASKAWA Page3
IPMM....Interior Permanent Magnet Motor
- High Efficiency
- Compact and light weight

Stator Windings Stator Windings

Point Flux

Magnetic
Torque Torque
&
Reluctance Torque

Rotor Rotor
Magnetic Torque Reluctance Torque

YASKAWA Page4
Functions and Performance for Riding Comfort
The Varispeed L7 has enhanced functions to assure a smooth, quiet, and
safe ride and it has a high efficiency for energy savings.

■ Zero servo and Starting torque compensation (load sensor is required)realize smooth start-up。
■ S-curve operation realizes smooth acceleration and deceleration。
■ Advance control suppresses torque vibration。

Without advance control With advance control

Motor speed
Torque reference

■ The alarm detection prevents an elevator from moving unexpectedly in case of


incorrect parameter settings, incorrect wiring, or motor failure.
■ The backup battery ensures safe elevator travel in case of power loss.
(An optional battery unit(Note)ensures the 48/96 VDC input.) * under develpment

YASKAWA Page5
Power Cycles
IGBT life time is above 3 million cycles under following operation condition

150%

100%
8kHz switching
0% 50% duty cycle
2s
12s

24s

YASKAWA Page6
Over-Load limit curves
Drive Over-load (OL2) is derated by following three curves

YASKAWA Page7
■ One motor MC instead of two while keeping compliance to the
EN81-1:1998 • The hardware baseblock function using the
terminals BB and BB1 must be used to enable
/disable the Inverter.
• If the elevator safety chain is opened, the Inverter
output must be cut. This means that the baseblock
signals at the terminals BB and BB1 must be
opened, e.g. via an interposing relay.
• The baseblock monitor function must be
programmed for one of the multi-function outputs
(H2-xx = 46/47). The regarding multi-function
contact must be implemented in the magnetic
contactor supervision circuit of the controller in
order to prevent a restart in case of an Inverter
baseblock or motor magnetic contactor malfunction.
• All magnetic contactors must be conform to the
EN81-1:1998.

One Magnetic
Contactor

YASKAWA Page8
Safety Function
■ Over-acceleration detection
Over-acceleration detection function blocks abnormal operation, and helps to
improve the safe operation of the elevator system

Acceleration
Abnormal acceleration

S3-16 Over-acceleration
detection level
Normal acceleration

t
Abnormal speed
speed

speed

Normal speed
t

signal
Over-acceleration
signal

YASKAWA Page9
■ Magnetic Pole Position Detection
<Principle> <Position detection method>
Motor impedance saliency can be detected by High frequency voltage is injected, and resulting high
injecting a high frequency voltage to a motor frequency current is detected through a Band-pass-
which is different from the operating frequency. Filter (BPF). Flux-Oriented_Controller (FOC) algorithm is
used for motor control.
L7B uses the motor saliency information to
detect the position of the magnetic pole.

30
e*
Vdinj
25
Impedance

fh =10 0 Current PWM


20 iγe*δ Control T(θˆ) VSI Motor
fh =2 0 0
fh =3 0 0
15 fh =4 0 0 iγe δ LPF T −1 (θˆ)
fh =5 0 0
Zh 10
fh =6 0 0
m
i dq i sdq
−1
[Ω] fh =7 0 0
BPF T (θˆ − 45 ) o
5
Sensor less θˆ
0
FOC
-90 -45 0 45 90
Pole Position qr[°]

Impedance Characteristics (Example) Control block diagram


(Injection voltage 30V,
30V,fh:
fh:Injection frequency Hz)

YASKAWA Page10
■ Excessive speed deviation detection level

YASKAWA Page11
Enhanced Braking
Braking functions as standard for models of 18.5kW or less.

Braking Resistor

P B
3-phase
Power supply MCCB
MC B1 B2
R R/L1 U/T1
S S/L2 V/T2 IM
T T/L3 W/T3
Motor

YASKAWA Page12
Input terminal logic can switch
Input terminal logic can switch between sink or source.

■ Sink Type ■ Source Type ■ Sink (Source) Type


【0V Commom 】 【+24V Common】 【External+24V DC】
NPN setting PNP setting ETX setting

S10 S10
S10

S11 S11
S11

S12 S12
S12

SC SC
SC

外部
+24V

jumper

Connection is possible to the various PLC output module.


YASKAWA Page13
Auto Tuning
① Rotational Auto-tuning
② Stationary Auto-Tuning new

③ Line-to-line resistance Auto tuning new



M M M
L7 L7 L7

During auto-tuning, Perform auto-tuning after Improve control performance


motor should not be motor is connected ★ Motor cable lead length is long
to load ★ Motor and inverter size is different
connected to load

High Accuracy even with Stationary Auto-tuning

YASKAWA Page14
4. Feature
4-1. Common
⑥ Easy Operation
★ The LCD panel digital operator optional that supports 7 languages.
★ Easy to setup with the quick program mode

A1-02 Control method sel. d1-17 Jog frequency ref. F1-01 PG constant
b1-01 Reference selection E1-01 Input voltage setting H4-02 Analog monitor gain
b1-02 Operation method sel. E1-03 V/f pattern selection (Terminal FM)
b1-03 Stopping method sel. E1-04 Max.output H4-05 Analog monitor gain
c1-01 Acceleration time 1 frequency (Terminal AM)
FWD REV SEQ REF ALARM E1-05 Max. voltage L1-01 Motor protection
REMOTE c1-02 Deceleration time 1
E1-06 Base frequency selection
c6-02 Carrier frequency
E1-09 Min.output freq. L3-04 Stall prevention
-QUICK- d1-01 Frequency ref. 1 E1-13 Base voltage selection during
d1-02 Frequency ref. 2
Control method selection d1-03 Frequency ref. 3
E2-01
E2-04
Motor rated current
No. of motor pole
accel

d1-04 Frequency ref. 4


A1-02= 0 *0*
E2-11 Motor rated capacity

V/f control
*0*

YASKAWA Page15
4. Feature
4-1. Common
⑥ Easy Operation
★ Constants can be easily up/down loaded using the copy function as standard.

★ The verify mode enables you to check all changed constants.

FWD REV SEQ REF ALARM


REMOTE
-ADV-
Copy function selection
o3-01=0 *0*
Normal operation
*0*

YASKAWA Page16
4. Feature
4-1. Common
⑥ Easy Operation (Drive Wizard 100TM)
Support tool using PC is also available. All constants of each inverter can be
managed by PC.

Read

Copy

Verify

YASKAWA Page17
4. Feature
4-1. Common
⑦ Global Standards

UL/cUL CE marking

C
U
® US
Certified under
UL/cUL and CE
Marking as
standard.(pending)

LISTED

■ Various Power Supply

Three-phase 200V series (200 to 240V)


Three-phase 400V series (380 to 460V)
YASKAWA Page18
4. Feature
4-1. Common
⑧ Supporting Global Field Networks
All models are fully compliant with RS-422/485(MEMOBUS/Modbus protocol) standards. The networks are
available by using communications option card. Now you can connect to hosts and PLC, implement centralized
management of production equipment and reduce wiring easily.

MEMOBUS(As standard)
DeviceNet
Field Networks

Profibus-DP
InterBus-S *
CC-Link
CANopen *
ControlNet *
LONWORKS *: Under development

Option card
for communication

YASKAWA Page19
Specification
■ 200V Class
Voltage class 200V Class
CIMR-L7B □□□□ 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055
Rated Motor rating kW 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55
Rated Output Capacity kVA 7 10 14 20 27 33 40 54 67 76 98
Output

Current A 17.5 25 33 49 64 80 96 130 160 183 224


Maximum voltage Three-phase 200/208/220/230/240V
Maximum frequency 120Hz
Voltage/frequency Three-phase 200/208/220/230/240V 50/60Hz
Input current A 21 25 40 52 68 96 115 156 176 220 269
Input

Allowable Voltage Regulation ±10%, -15%


Allowable Frequency Regulation ±5%
Harmonics

DC reactor Option -
Harmonic
reduction
12-phase rectifier N/A

■ 400V Class
Voltage class 400V Class
CIMR-L7B □□□□ 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055
Rated Motor rating kW 3.7 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55
Rated Output Capacity kVA 7 9 12 15 22 28 34 40 54 67 80 106
Output

Current A 8.5 11 14 18 27 34 41 48 65 80 96 128


Maximum voltage Three-phase 380/400/415/440/460/480V
Maximum frequency 120Hz
Voltage/frequency Three-phase 380/400/415/440/460/480V 50/60Hz
Input current A 10.2 13.2 17 22 32 41 49 58 78 96 115 154
Input

Allowable Voltage Regulation ±10%, -15%


Allowable Frequency Regulation ±5%
Harmonics

DC reactor Option -
Harmonic
reduction
12-phase rectifier N/A

YASKAWA Page20
YASKAWA Page21
YASKAWA Page22
MC Upper Level Controller MC
(Run permission command) (Run permission input)

K01

K2

Safety
chain
DC reactor Braking resistor unit
K1 (option) (option)
U X

(+1) (+2) (-) B1 B2


motor
MCCB MC U
L1 R/L1 U/T1
3-phase power
380~480V L2 CIMR-L7B43P7 V
S/L2 V/T2 IM/PM
50/60 Hz
W
L3 T/L3 W/T3

Input voltage for control power


P0 PG-X2
200 V Class: 250 to 300VDC *8 (Option card)
N0
400 V Class: 500 to 600VDC0V TA1
1 12V
2 0V
S1 3
Forward run/stop 4 A+
5 A-
6 B+ PG
Reverse run/stop S2 7 B-
8 Z+
9 Z-
10
Nominal speed S3 *1
TA3
Inspection Run S4
Multi-function
contact inputs Intermediate speed S5 TA2
1
(Factory setting)
2 A pulse Pulse monitor output
Leveling speed S6 3
RS-422 Level

4 B pulse Wiring distance: d : 30 m max.


Not used S7
5
Hardware
baseblock 1 *9 Zpulse
24V BB 6

Hardware
7
SG
baseblock 2 BB
+24V 8mA

SC 24V

*5
CN5(NPN setting)
E(G) Shield wire
connection terminal

Frequency setting
adjustment
*3 Frequency setting MA
External +V MA Fault contact output
power +15V, 20 mA 250 VAC, 10 mA min. 1 A max.
frequency Frequency 3 2kΩ MB 30 VAC, 10 mA min. 1 A max.
setter 2 0~+10V
reference
2kΩ A1 Master speed Min. load
1 reference
MC 5 VDC,10 mA
0~10V(20kΩ) MC
AC *6
0V M1
Terminating M2 Multi-function contact output 1
resistance
Factory setting:
R+ Brake release command
Multi-function contact output
M3 250 VAC, 10 mA min. 1 A max.
MEMOBUS R- Multi-function contact output 2 30 VAC, 10 mA min. 1 A max.
communications M4 Min. load
RS-485/422
S+ Factory setting: 5 VDC,10 mA
Magnetic contactor control

S- M5
Multi-function contact output 3
M6
Factory setting:
Inverter operation ready

Communication and 2CN


Control Cards
(For Option)

YASKAWA Page23
Drive Dimension
■ Open Chassis (IP00)

■ Open Chassis (IP00)


Motor Dimmensions mm Mass Caloric Values (Losses) Cooling
Voltage Capacity CIMR-L7B □
W H D W1 H1 H2 D1 T1 d kg External Internal Total type
kW
3.7 23P7 112 74 186
140 280 177 126 266 7 59 5 M5 4
5.5 25P5 164 84 248
7.5 27P5 6 219 113 332
200 300 197 186 285 8 65.5
11 2011 7 374 170 544
15 2015 429 183 612
200V 240 350 207 216 335 78 2.3 M6 11
18.5 2018 501 211 712 Fan
(3ph) 7.5
22 2022 250 400 195 385 21 586 274 860
258 100
30 2030 275 450 220 435 24 865 352 1217
200V/400V Class 0.4~18.5kW Drives 37 2037 298 100 57 1015 411 1426
375 600 250 575
45 2045 328 12.5 3.2 - 63 1266 505 1771
130
55 2055 450 725 348 325 700 86 1588 619 2207
3.7 43P7 80 68 148
4.0 44P0 140 280 177 126 266 7 59 5 M5 4 91 70 161
5.5 45P5 127 82 209
7.5 47P5 193 114 307
200 300 197 186 285 8 65.5 6
11 4011 252 158 410
400V 15 4015 326 172 498
240 350 207 216 335 78 10 Fan
(3ph) 18.5 4018 426 208 634
22 4022 2.3 M6 466 259 725
275 450 258 220 435 100 21
30 4030 7.5 678 317 995
* *
* 37 4037 784 360 1144
* In case of 200V Class 37~55kW,(10) 45 4045 325 550 283 260 535 105 36 901 415 1316
200V/400V Class 22~55kW Drives 55 4055 1203 495 1698

YASKAWA Page24