Sei sulla pagina 1di 11

Value Unit Check

Grade of Concrete 25 N/mm^2


Grade of Steel 410 N/mm^2
Φ value 15 degree
Cohesion value= 2.5 t/m^2
Unit Weight of Soil= 1.5 t/m^3
Depth of foundation (Assuming) 2m
Type of base of column Circle
Ultimate Net Bearing Capacity= 23.79 t/m^2
Load on the column 21.815 kn
2.22 t
Moment acting on the column along X-X direction 0.313 kn m
0.032 t m
Moment acting on the column along Y-Y direction 0.288 kn m
0.029 t m
Considering Area of footing 2.4 sq m
Length= 0.8 m
Breadth= 3m
Maximum Load on the soil 9.12 t/m^2 OK
Assuming 10% extra load for the column
Total load 10.03 t/m^2 OK
Moment acting on the footing along X-X 0.17 t m
Moment acting on the footing along Y-Y 6.06 t m
Depth of Footing 41.91 mm
Considering depth of footing 250 mm
Main Steel Dia (mm) 12 mm
Distribution Steel dia (mm) 10 mm
Clear Cover (mm) 50 mm
Effective depth of footing(mm) 184 mm
Reinforcement (mm^2) 994 mm^2
Spacing= 114 mm
Distribution Steel @ 0.12% 220.8 mm^2
Spacing= 250 mm
Check for Shear OK
Y

0.80

1.322

0.356 3.00

1.322

0.222 0.222
X
Value Unit Check
Grade of Concrete 25 N/mm^2
Grade of Steel 500 N/mm^2
Φ value 30 degree
Φ value to be taken 21.05 degree
Cohesion value= 1.8 t/m^2
Unit Weight of Soil= 1.8 t/m^3
Depth of foundation (Assuming) 2m
Ultimate Net Bearing Capacity= 44.51 t/m^2
Load on the column 162.523 kn
Load due to backfilling 317.844
122.42 t
Moment acting on the column along X-X direction 137.082 kn m
34.934 t m
Moment acting on the column along Y-Y direction 45.81 kn m
11.674 t m
Considering Area of footing 9 sq m
Length= 3m
Breadth= 3m
Maximum Load on the soil 25.82 t/m^2 OK
Assuming 10% extra load for the column
Total load 28.40 t/m^2 OK
Moment acting on the footing 16.13 t m
Depth of Footing 68.38 mm
Considering depth of footing 500 mm
Main Steel Dia (mm) 16 mm
Distribution Steel dia (mm) 16 mm
Clear Cover (mm) 50 mm
Effective depth of footing(mm) 426 mm
Reinforcement (mm^2) 892 mm^2
Spacing of main steel= 225 mm
Distribution Steel @ 0.12% 511.2 mm^2
Spacing of distribution steel= 250 mm
Check for One way Shear OK
Check for Two way Shear OK

6.6 1.5
6.6 2.5
6.6 2
Φ Nc Nq Nϒ
0 5.14 1 0
5 6.49 1.57 0.45
10 8.35 2.47 1.22
15 10.98 3.94 2.65
20 14.83 6.4 5.39
25 20.72 10.66 10.88 1.175
30 30.14 18.4 22.4
35 46.12 33.3 48.03
40 75.31 64.2 109.41
0.65
45 138.88 134.88 271.76
50 266.89 319.07 762.89

0.3849001795 0.3674219 21.051724


1.175
Minimum Depth of Foo0.1273148 m

9.3 9.81 91.233 1.175

9
1.21
7.79

0.75
0.325
0.425
1.2

4.4 43.164 47.553 4.8474006 6.6 1.3615545


2.64 25.8984
3.3 32.373
Y

3.00

0.65

3.00 X

7.70 t m
1.175

8.736
16.6 t

28.42 t-m
DESIGN OF ISOLATED FOOTING OF TOLL PLAZA CANOPY A

Material Constant
Grade of Concrete 25 N/mm^2
Grade of Steel 415 N/mm^2
Load factor 1.5
Column Details
Length=(Larger Dimension of Column) 0.5 m
Breadth=(Smaller Dimension of Column) 0.5 m 1.250
Forces Details
Load on the column 6.60 t
Moment acting on the column along X-X direction 9.30 tm
0.5
Moment acting on the column along Y-Y direction 0.10 tm
Footing Details
Length= 3 m
Breadth= 3 m
Depth= 0.5 m 1.250
Cover to main Reinforcement 0.05 m
Diameter of Reinforcement in Footing 16 mm
Soil Details
Unit Weight of Soil= 1.8 t/m^3 1.250
Depth of foundation (Assuming) 1.5 m
Φ value 20 degree
Cohesion value= 1.8 t/m^2
Design Forces
Axial Load 9.90 t
Self Weight of Footing 12.42 t
Soil Backfilling 24.30 t
Total Load 46.62 t

Pressure calculation
Φ value to be taken(If Local shear Failure Occured) 13.64 degree
Ultimate Net Bearing Capacity= 15.64 t/m^2
Pmax=(P/A)+(Mxx/Zxx)+(Myy/Zyy) 8.31 t
SAFE
Pmin=(P/A)-(Mxx/Zxx)-(Myy/Zyy) 3.09 t 0.5
TENSION NOT CREATED
Moment at Critical Section Along Length
Moment= 6.50 t-m 3.09 t m
Mu= 87.92 t-m
Area of Steel= 421.39 mm²
Req. area of steel= 511.20 mm²
Required 16φ @ 393.31 mm
Providing 16φ @ 200 mm
Area of steel Provided= 1005.31 mm²
Moment at Critical Section Along Width
Moment= 6.50 t-m
Mu= 87.92 t-m
Area of Steel= 421.39 mm²
Req. area of steel= 511.20 mm²
Required 16φ @ 237.13 mm
Providing 16φ @ 200 mm 1.250
Area of steel Provided= 1005.31 mm²
Check for One way Shear Along Length
Critical Section is at "d" from the face of the column
0.5
Shear force at the critical section= 6.85 t
Actual Shear Stress= 0.24 N/mm^2
Percentage of Steel= 0.24
Design Shear Strength of Concrete= 0.29 N/mm^2
SAFE 1.250
Check for One way Shear Along Width
Critical Section is at "d" from the face of the column
Shear force at the critical section= 6.85
Actual Shear Stress= 0.24 1.250
Percentage of Steel= 0.24
Design Shear Strength of Concrete= 0.29
SAFE
Check for Two way Shear
Critical Section is at "d/2" from the face of the column
Shear force at the critical section= 67.69 t
Critical perimeter 3.70 m
Actual Shear Stress= 0.64
Allowable Shear Stress= 1.25 N/mm^2
SAFE
Check for Overturning along Length
Restoring Moment= 14.85 t-m
Applied Moment= 0.10 t-m
SAFE
LL PLAZA CANOPY AT COOCHBEHAR
Y

3.00

0.5

3.00 X

1.250

0.7 t

0.5

8.31 t-m
3.00

0.5 0.426

3.00

1.250

Potrebbero piacerti anche