BL = blocked
BL-BCF= blocked-bcf_fault
BL-BTS= blocked-bts_fault
BL-CF = blocked-cu/fu_fault
BL-CLK= blocked-clock_fault
BL-CU = blocked-cu_fault
BL-DGN= blocked-diagnostic
BL-FLO= blocked-floating
BL-FTY= blocked-faulty
BL-FU = blocked-fu_fault
BL-PWR= blocked-mains_power_fault
BL-RSL= blocked-rsl_fault
BL-RST= blocked-reset
BL-SHD= blocked-shutting_down
BL-SU = blocked-bcsu_reset
BL-SWO= blocked-background_data_switchover
BL-SYS= blocked-system
BL-TRX= blocked-trx_fault
BL-TSL= blocked-timeslot_fault
BL-TST= blocked-testing
BL-USR= blocked-user
BL-WAC= blocked-waiting for autoconfiguration
Check apakah ada status TRX,BTS atau Site dan OMU dalam kondisi tidak WO
?
Jika ya
1. Hanya 1 TRX dalam satu sektor
BL-TRX or BL-SYS;
Check alarm history atau current alarm
- Jika ada masalah dengan HW maka coba reset dengan cara Lock-
unlock TRX ( ZERS:BTS id:TRX id:L/U; )
- Jika problem masih ada coba disable-enable LAPD di TRX tsb.
ZDTC:NAME LAPD:BL/WO;
- Jika not solve report ke engineer area bersangkutan (
coordinator area ) atau all bss biar semua tahu untuk difollow
up nantinya
- Jika hanya ada alarm Fault rate saja bisa saja koneksi kabel di DDF
tidak bagus.
PCM STATISTICS
PERMANENT MEASUREMENT
DISTURBANCES:
NOINSGN 0 0 0 0
FALOST 0 0 0 0
AIS 0 0 0 0
REMOTE 0 0 0 0
0 0 0 0
SLIPS:
POSITIVE NEGATIVE
0 0
8. Jika site off karena ET failure dengan mengetahui dari ZAHO maka coba
reset ET : 1. ZUSC:ET,et number:BL:fcd; buat status block
2. ZUSC:ET,et number:TE:fcd; buat status Test
3. ZUDU:ET,ET NUMBER:::;
4. Check status diagnose sampai mana
ZUDH; jika sudah ada informasi no diagnostic
5. Check hasil diagnostic
ZUDH:ET,NOMER ET::YYYY-MM-DD,:; ATAU CUKUP DENGAN
ZUDH:ET,NOMER ET:::;
9. Dari ZEOL dan ZEEL jika ada masalah berhubungan dengan performansi TRX,
sektor maupun Site.
- Masalah performansi di site
Contoh : 7124, 7125, 7126, 7127-7138, 7508,7511, 7538, 7601, 7604, 7606 dan lihat
detailnya di alarm printout.
- contoh 7743/7745 = mean holding time below threshold artinya call
tidak pernah berhasil diatas 4 detik di timeslot atau channel TRX
tertentu
Coba check via service terminal
ZDDS:; lalu ketik ? apakah indek Radio Resource Monitoring ada ?
Jika belum aktifkan sbb : ZLE:index,E00_BXSX; pilih index yang
belum ada saya buat disini N sebagai index
CONTOH;
1. Untuk bisa execute setelah mengaktifkan service terminal
diataslalu ketik ? dan ketik index diikuti enter.
2. CHECK eaktu pendudukan; ( ditandai dengan OCCU or occupancy
hitungan dalam hexa & nanti deterjemahkan dalam detik / decimal
TC:BTS id dalam hexa,TRX id dalam hexa;
00-MAN>?
G ..... COMPUTER LOG HANDLER (DEF) P ..... BCF PHASE MONITORING (LOA)
M ..... MASS MEMORY HANDLING N ..... RADIO RESOURCE MON (LOA)
00-RRM>TC:4,1
Contoh print out
2007-05-10 11:54:32.13
DX 200 BSC RADIO CHANNEL INFORMATION FOR BTS NUMBER 04
TRX 02 N-TRX REGULAR PCM 01E0 ARFCN 0001 LINK ID 0044 BITRATE 0020
TSL _CONFIG ____ STATE __ STATUS _______ IF-LVL ___ CALL TIME TIME ___ USAGE
FR,HR0 HR1 F0 H0 H1 FR,HR0 HR1
-00 PERM FR WORKING IDLE 00 00000000 CSW
-01 PERM FR WORKING OCCU 00 000000BA CSW
-02 PERM FR WORKING IDLE 00 00000000 CSW
-03 PERM FR WORKING IDLE 00 00000000 CSW Oendudukan dalam
-04 PERM FR WORKING OCCU 00 00000028 CSW hexa , CSW = circuit
-05 PERM FR WORKING IDLE 00 00000000 CSW switch
-06 PERM FR WORKING OCCU 00 00000009 CSW
-07 PERM FR WORKING OCCU 00 00000000 CSW
> Coba check apakah hanya 1 TRX atau 2 TRX dibaseband yang sama
Jika hanya 1 TRX coba reset atau lock-unlock TRX.
Jika alarm masih muncul coba info ke engineer areanya untuk
check HW di site tsb untuk check konfigurasi baik mencocokkan
mapping timeslot di BTS manager dengan BSC via
ZDSB:NAME=T0BCFidTRXid; CHECK lapd name bisa dilihat dari
DTI:::PCM=; dan ZERO:BTS=X,TRX=X:; CHECK TIMESLOT TRX
Jika semua sama coba langkah dibawah
Reset TRX jika masih lakukan dibawah
On site check konfigurasi dan jika ok coba dibawah
Replace HW diTRX maupun baseband.
Jika ada alarm ditrx di baseband yang sama maka perlu ganti
Baseband or lainnya disite.
> 7745 / channel failure
Masalah ini call akan selalu fail bisa dilakukan langkah seperti
7743 diatas
==================================================================
CHECK STATUS DAN ALARM BSC LEVEL PER HOURS
==================================================================
CHECK STATUS OMU ( OPERATION MAINTENANCE UNIT )
ZUSI:OMU;
CHECK ALARM OMU
ZAHO:OMU;
ZAHP:MB,:::;
CHECK SINKRONISASI BSC ( 2M1 = ATER 32, 2M2 = ATER 96, 2M3 = ATER 160, 2M4 = ATER 224 )
ZDRI;
SGSN
YMO:ET,32;
PCM STATISTICS
PERMANENT MEASUREMENT
DISTURBANCES:
0 0 0 0
SLIPS:
POSITIVE NEGATIVE
0 0
CRC PERFORMANCE MONITORING:
TOTAL AVAIL UNAVAIL
TIME TIME TIME
LOCAL END 15:12:25 15:12:25 00:00:00
REMOTE END 15:12:25 15:12:25 00:00:00