Sei sulla pagina 1di 4

Fanuc-3 RS232

Fanuc-3
Parameter Value Comments
0014
0069 4800 Baud rate
TV CHECK0 0: Off; 1: On
Punch code 0 0:ISO; 1:EIA

Fanuc 6 and 9 series RS232


Fanuc 6 and 9 series Baud rateParameter
Parameter Value Comments 50 00010000
311 00011000Baud rate 2400 100 00010001
340 2 110 00010010
341 2 150 00010011
TV CHECK 0 0: Off; 1: On 200 00010100
Punch code 0 0:ISO; 1:EIA 300 00010101
Input unit 0 RS232C 600 00010110
Input device 1 1 1200 00010111
2400 00011000
Input device 2 1 4800 00011001
9600 00011010

Fanuc 0M RS232
Fanuc 0M CNC Port 1 Port 2
Parameter(M5) (M74)
On the SETTINGS 0002 1xxxxxx1no effect
screen, set the 0050 no effect 1xxxxxx1
following: 0038 01xxxxxxxx01xxxx
TVON =0 9-Baud
ISO = 1 0552 rate: no effect
I/O = 0 (port 1), I/O = 2 2400
(port 2)
PWE = 1 0253 no effect 10
TAPEF = 0
X means can be 0 or 1
Fanuc- 0i-M/0i-T RS232 communication
Fanuc 0i-M/0i-T
Parameter Value Comments
0000 00000010
0020 0
0100 00100000
0101 10000001
0102 0
Baud rate
5=150
6=300
7=600
0103 11
8=1200
9=2400
10=4800
11=9600
TV CHECK 0 0: Off; 1: On
Punch code 0 0:ISO; 1:EIA
Input device 0 RS232C

Fanuc RS232-10/11/12/15
Fanuc 10/11/12/15
Parameter Value Comments
5001 1
5002 2
5003 3
5110 4
5111 2
5112 9 Baud rate 2400
5120 4
5121 2
5122 9 Baud rate 2400
5130 4
5131 2
Baud rate
5=150
Enter 5-11 6=300
in parameter 7=600
5132
depending on 8=1200
baudrate 9=2400
10=4800
11=9600
TV CHECK 0 0:Off; 1:On
Punch code 0 0:ISO; 1:EIA
Input device 1 RS232
Output device 1 RS232
Fanuc-16/18/21 (M,T,I series)
To change parameters- Press the offset settings hardkey, then press settings softkey.
To turn on PWE. To get to parameters press system hard key then the parameter
softkey

Fanuc 16/18/21(M,T,I series)


Parameter Value Comments
0000 00000010
0020 0
0100 0
0101 10000001
0102 0
Baud rate
5=150
6=300
7=600
0103 11
8=1200
9=2400
10=4800
11=9600
TV CHECK0 0: Off; 1: On
Punch code 0 0:ISO; 1:EIA
Input device 0 RS232
Communications standard non handshaking cable
For more wiring diagrams check out the RS232 cable wiring pinout

6 = Data Set Ready


7 = Signal Ground
8 = Carrier Detect
20 = Error (Data Terminal Ready)
25 = Power

Baudrate-Feet
2400-400ft
4800-200ft
9600-100ft
19200- 50ft
38400-25ft
57600-16ft
115200-8ft

Fanuc ISO Protocol communication settings: (E,7,X)

The standard protocol for Fanuc controls is 4800 or 9600 Baud, Even parity, 7 data
bits and either 1 or 2 stop bits (XON/XOFF, PUNCH ON/OFF). This is standard
setting that will work in most conditions. Depending on environment and cable type
and distance to DNC if used.

Potrebbero piacerti anche