GRADUATING

JBC GROUP DESIGNING CORPORATION


NO. BY DATE REVISION
A SKPB 12/10/2017 DESIGN
ANALYSIS TRANSMITTERS
H2S ANALYSIS TRANSMITTER

1 P&ID DRAWING
TAG NO. SEE SHEET 3
2 SEE SHEET 3
3 FUNCTION TRANSMIT
4 BLIND/INDICATE BLIND
5 CASE OUTDOOR WEATHER PROOF
6
7 MOUNTING THREADED
8
9 ENCLOSURE ALUMINUM AL6061
10
GENERAL 11 POWER SUPPLY
12 ST3 XCHEM 24VDC
13
14 BIOGAS 3000 110-230 VAC/50-60HZ
15
16
17
18
19
20 TRANSMITTER OUTPUT x6 ,4-20mA DC
TRANSMITTER 21
22
23 CONTROL MODES N/A
24 N/A
25 ACTION N/A
PROCESS DATA 26 AUTO-MANUAL SWITCH N/A
27 SET POINT ADJUSTMENT N/A
28 MANUAL REGULATOR N/A
29 OUTPUT N/A
30 SERVICE SEE SHEET 3
31
32 MATERIAL ALUMINUM AL6061
33 RATING 0-50PPM
UNIT 34
35 PROCESS CONNECTION EQUIPMENT TAP/IN-LINE
36 ELECTRICAL CONNECTION 1/2" FNPT FITTING
UNIT

37
38
39 ALARM SWITCHES N/A
SWITCH 40
41
42 OPTIONS FLANGE MOUNTING(for ST3)
OPTIONS
43 STAMPED STAINLESS STEEL TAG
44 MFR & MODEL ST3 XChem TOXIC GAS SENSOR
MFR & MODEL
45 GEOTECH BIOGAS 3000
NOTES
SHT 2 OF 3
SPEC NO. REV.
XX.XX.XX A
CONTRACT DATE
XXXX 12/10/2017
REQ./P.O.

BY CHECKED APPR.
SKPB
SERVICE
SEE SHEET 3
PROJ. NO. XXXXX
GRADUATING CLIENT:
UNIT NAME:
JBC GROUP
SEE PAGE 3
DESIGNING CORPORATION LOCATION: BATANGAS PH

H2S GAS TRANSMITTER DATA SH


1.0 GENERAL

1.1 Vendor shall provide protection adequate for shipment and storage of instruments. All openings and exposed p
entering. All flanges and threaded connections shall be protected using wood, steel, or plastic protectors.
.

1.2 Vendor shall clearly state any, and all exceptions in a seperate sections of qoute labelled "Exceptions & Clarificati

1.3 In the event model number given conflicts with other data provided, the model number shall be ignored, and th
making changes.

1.4 Unless noted otherwise all electrical accessories shall be approved for use ina outdoor Class 1 Division 2 Groups

1.5 Vendor data shall be provided in strict accordance with Attachment 1 "Drawing and Data Schedule".

1.6 Vendor shall verify factory calibrationof transmitters to "Calibrate Range"listed. Each Device shall be configured
PAGE: 1 OF 3
SPEC: XX.XX.XX
REV: A
BY: SKPB APP:
DATE: 12/10/2017

TTER DATA SHEET

ts. All openings and exposed parts shall be protected, so as to prevent debris from
el, or plastic protectors.

belled "Exceptions & Clarification".Failureto do so shall imploy vendor has no exceptions .

umber shall be ignored, and the data provided will govern. Notify Sheldon Bool prior to

door Class 1 Division 2 Groups B, C, and D.

d Data Schedule".

ch Device shall be configured with th device tag number,and sevice listed.


GRADUATING
JBC GROUP DESIGNING CORPORATION
NO. BY DATE REVISION
A SKPB 12/10/2017 DESIGN
ANALYSIS TRANSMITTERS
H2S ANALYSIS TRANSMITTERS

REV TAG NO. CALIBRATED RANGE ENGINEERING UNITS SERVICE

AT-201 1-15FT 5METERS DS-T-201 Desulphurization Tank


AT-202 1-15FT 5METERS CP-201A/B Centrifugal Pump To DS-T-201 Desul
NOTES:
1. H2S ALARM
2.GAS ANALYSIS FOR METHANE & H2S (GEOTECH BIOGAS 3000)
SHT 3 OF 3
SPEC NO. REV.
XX.XX.XX A
CONTRACT DATE
XXXX 12/10/2017
REQ./P.O.

BY CHECKED APPR.
SKPB

SERVICE P&ID DWG NOTES

DS-T-201 Desulphurization Tank BG100-PID-102 1


ntrifugal Pump To DS-T-201 Desulphurization Tank BG100-PID-102 2