R410A

ENVIRONMENT FRIENDLY
REFRIGERANT

n
y
Sm

gn
n
g er om l ex

C
S
Hi

ig
dl
art D es i i

F
gh EER vi c
e F r ie
n p ac t Des i ble D es

YORK® PREDATOR® SERIES


SINGLE-PACKAGED ROOFTOPS
6.5 - 10 TON
60 Hertz
R410A
ENVIRONMENT FRIENDLY
REFRIGERANT

YORK® Predator® units are convertible single packages with a common footprint cabinet
Models. All 6-1/2 through 10 ton units have two compressors with independent refrigeration
circuits to provide 2 stages of cooling. These units are designed for light commercial
applications and can be easily installed on a roof curb, slab, or frame.

Features and Benefits


▪ High Efficiency –Efficiencies exceed SASO
legislated minimum levels and provide low operating costs.
▪ – The Predator® incorporates a number
of enhancements which improve serviceability.
-Slid out blower assembly.
-Hinged tool less access panel.
-Slide out and reversible drain pan.
▪ Dual-stage cooling for maximum comfort.
▪ Dual-stage electric heaters for all models
▪ Simplicity® Control board with screw connector for
thermostat wiring.
▪ Full Perimeter Base Rails with forklift slots and rigging
holes.
▪ Micro-Channel “all-aluminum” condensers to provide
improved heat transfer capabilities at reduced charge
volumes.
▪ All models with same footprint for flexible placement.
▪ Belt-drive blower motors in all models can supply
nominal airflow at a minimum of 1.5” ESP.
▪ Flexible Installation-Convertible back and bottom duct
openings. Advanced Simplicity® Controls
▪ System Protection with Freezestat, Hi and Low pressure
switches. The Simplicity® Control System is part of each Predator®
models. It monitors the entire HVAC system continuously. All
alarm and diagnostic data can be set up and transmitted di-
rectly to an onsite PC. Or, can monitor the system over the
Internet. Simplicity® control boards have following features
as standard;
• Single-button programming.
• Five-minute anti-short cycle delay.
• Low Ambient control.
• Programmable fan on and off delays.
• Alarm recall, even after power failures.
• Three-minute minimum compressor run time.
• Built-in low-voltage protection.
• Independent monitoring of all safety switches.
R410A
ENVIRONMENT FRIENDLY
REFRIGERANT

YORK offers several factory installed or field installed equipment options for the Predator roof
top packaged units.

Factory Installed Options


▪ - Predator return air configurations.
units offer a variety of optional factory installed
▪ 2” Pleated MERV 7 or 4” Pleated MERV 13 are
economizers with low leak dampers. The outdoor air
available to meet LEED requirements.
enthalpy sensor enables economizer operation if the
outdoor enthalpy is less than the set point of the ▪ – Available as option for units with
economizer logic module. reciprocating compressor.
▪ - A factory-installed variable
frequency drive (VFD), mounted in the Blower Access ▪ – Available as factory installed option
compartment, is used to control the speed of the indoor or field installed accessory.
blower motor in order to maintain a constant static
pressure in the supply duct. A pressure transducer and ▪ HGBP is must select option on all units
VAV control board are mounted inside the control box. with VAV and optional with constant-volume units.
The drive comes completely wired and pre-programmed
▪ The Condenser Coils are
from the factory.
coated with a phenolic coating for protection against
▪ An optional rust-proof corrosion due to harsh environments.
stainless steel drain pan is available to provide years of
▪ The Condenser
trouble-free operation in corrosive environments.
Coils are coated with an epoxy polymer coating to
▪ - The electric heaters range from 3 kW protect against corrosion.
to 54 kW and are available with single point power supply.
▪ Coating is applied by
▪ - HACR breaker sized to the unit is spray for maximum corrosion protection.
provided factory installed on unit.
▪ Cu/Cu
▪ - Available for both the supply and/or evaporator coil option is available for all models.
Technical Specifications
Component

Nominal Tonnage 6.5 7.5 8.5 10

Gross Capacity MBH (KW) 81 (23.7) 93 (27.3) 107 (31.4) 125 (36.6)
Net capacity MBH (KW) 78 (22.9) 90 (26.4) 102 (29.9) 120 (35.2)
EER 11.7 11.7 11.7 11.7
IEER 12.8 12.8 12.8 12
Nominal CFM 2600 2700 3400 4000
System power HP (KW) 9 (6.7) 10.3 (7.7) 12.1 (9) 13.9 (10.4)
Refrigerant type R-410A

Length inch (mm) 89 (2260.6) 89 (2260.6) 89 (2260.6) 89 (2260.6)


Width inch (mm) 59 (1498.6) 59 (1498.6) 59 (1498.6) 59 (1498.6)
Height inch (mm) 42 (1066.8) 42 (1066.8) 50.75 (1289.1) 50.75 (1289.1)

Type Recip Scroll


Quantity 2 2 2 2
Unit Capacity Steps (%) 50 / 100 50 / 100 50 / 100 50 / 100

Face area ft² (m²) 23.8 (2.2) 23.8 (2.2) 29 (2.7) 29 (2.7)
Rows 1 1 1 1
Fins per inch 23 23 23 23
Tube diameter inch (mm) 1 (25) 1 (25) 1 (25) 1 (25)
Circuitry Type 2-pass Microchannel

Face area ft² (m²) 10.6 (0.99) 10.6 (0.99) 13.2 (1.2) 13.2 (1.2)
Rows 3 3 3 4
Fins per inch 15 15 15 15
Tube diameter inch (mm) 0.375 (9.5) 0.375 (9.5) 0.375 (9.5) 0.375 (9.5)
Circuitry Type Intertwined
Refrigerant control TXV

Quantity of fans 2 2 2 2
Fan diameter inch (mm) 24 (609.6) 24 (609.6) 24 (609.6) 24 (609.6)
Type Prop
Drive type Direct
Quantity of motors 2 2 2 2
Motor HP (KW) 1/3 (0.25) 3/4 (0.56) 3/4 (0.56) 3/4 (0.56)
No. speeds 1 1 1 1
RPM 850 1110 1110 1110
Nominal total CFM 6700 8600 9400 9400

Quantity 1 1 1 1
Fan Size (inch) 12 x 12 12 x 12 15 x 15 15 x 15
Type Centrifugal
Motor HP (KW) 1.5 - 2 (1.1 -1.5 ) 1.5 - 3 (1.1 - 2.2) 2 - 3 (1.5 - 2.2) 2 - 3 (1.5 - 2.2)
RPM 1725 1725 1725 1725
Frame size 56 56 56 56