Data requistion sheet for Contr. Job No.:
DC UNITERRUPTABLE POWER SUPPLY (DC UPS) MESC No.:
REQUIREMENTS SPECIFIED BY PRINCIPAL
REMARKS
1 Tag Number(s) ………………….……...
2 Nominal rated output ………......… kW DC
3 Required autonomy time 30mins/…….….....hours
4 Rectifier type SMPS / Thyristor / other
5 Battery type required Lead acid: VRLA/vented NiCd:Low maint/vented
6 Language Labels: English/…………... Manuals: English/………..
7 SITE CONDITIONS
8 Site location Temperate / tropical
9 Site max ambient/humidity ………….…...….. / 40 °C …………………..… / 90%
10 Altitude 1000 m/…..……………….
11 Location of DC UPS Unit Conditioned room / ………………………..
12 Location of batteries Battery room / cubicle
13 Cabling distance between UPS unit and battery ..…….….….….……… / 20m
14 Battery room size (length x breadth x height) ………..……..m x ……..………. m x ..…………… m
15 Battery room temperature ……….° C max x ……… °C average x .…… °C min
16 MAINS INPUT
17 Voltage/frequency 110/220/400/ …………...………..……… V 50/60 Hz
18 Supply system and earthing 1/3 phase 3/4 wire TN-S / TN-C / IT
19 Short circuit capacity of mains intake ………….....…….. MVA
20 OUTPUT
21 Voltage 24/48/110/220/ …….……………………. V DC
22 Blocking diodes required yes / no
23 COMMUNICATION
24 Remote SCADA software monitoring required (4.8) yes / no RS485 / Fibre optic Separate quote required
25 Modem for linking to Vendors service centre yes / no Separate quote required
26 GENERAL REQUIREMENTS
27 Cable entry Below / Above
28 Estimated cable sizes AC input ……sq. mm DC output……………..sq. mm
29 TESTING/SERVICE/SPARE PARTS
30 Factory acceptance tests to be witnessed yes / no
31 Service contract required/duration yes/ no ………………….…. years Separate quote requred
32 Type of service contract Maintenance / Breakdown / Full spares
33 Spare parts quotation for 2 years required yes / no Separate quote required
34 SPECIAL REQUIREMENTS AND REMARKS
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
49
50
Made by: Date EQUIPMENT: Rev. letter
Date
Checked by: Date PLANT : Sign.

Appr. by: Date CONSIGNEE : Sheet No. continued on sheet No.

Eng. by : Equipment No.


Principal : Req. No.
PTS 13.90.004-Gen., sheet 1/2, October 2000
Design book No.: page
Data requistion sheet for Contr. Job No.:
DC UNITERRUPTABLE POWER SUPPLY (DC UPS) Continued… MESC No.:
INFORMATION PROVIDED BY VENDOR
RECTIFIER REMARKS
1 Rated ouptut ………….... kW ...………..…. VDC ….……………. A
2 Rated input …….…......... kVA .....….……. A …..……........ VAC
3 Recommended rating of AC input fuse ……………...…… A Type gG
4 Recommended rating of DC output fuse ………………...… A
5 Expected mains input voltage distortion ……………….... % of RMS
6 Rectifier cooling Natural ventilation / fan cooled
7 Output voltage ripple ………………... % of RMS C 10 amps
8 BATTERY
9 Nominal battery capacity …………………. AH Attach calculation
10 Battery design lifetime 10 / 15 / 20 / ……………… years
11 Actual battery autonomy time at rated output 30 / ………………………..…. mins
12 Idc (max) …………………..…...…...... amps
13 Required sizing of battery cables …………………………….. sq. mm
14 Battery switching device ………………..….. A Fused switch/MCCB/MCB
15 No. of air changes per hour required ………………………. / hr
16 PERFORMANCE CHARACTERISTICS REMARKS
17 Efficiency of rectifier 1/1 load ………….% 1/2 load ………………..%
18 Predicted reliability (MTBF) ……………..hours
19 Noise level dB(A) at 1 m ………………….dB (A)
20 DIMENSIONS & WEIGHTS DC UPS UNIT
21 Width x height x PTSth DC UPS unit ………………………..(w x l x d) mm
22 Width x height x PTSth battery ………………………..(w x l x d) mm
23 Weight: DC UPS/battery ………….……. kg/ …..…………… kg
24 GENERAL
25 Country of origin ……………………………..
26 Location of nearest service centre ……………...……………..
27
28 SPECIAL REQUIREMENTS AND REMARKS
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48

Sheet No. continued on sheet No.

Eng. by : Equipment No.


Principal : Req. No.
PTS 13.90.004-Gen., sheet 2/2, October 2000

Potrebbero piacerti anche