MultiScan MS 5800 E™ System MultiScan MS 5800 U™ System
Tube Inspection with Tube Inspection with an Internal
Eddy Current Testing (ECT) Rotating Inspection System (IRIS) for
■ Condensers Ferrous and Nonferrous Materials
■ Feedwater heaters
■ Boilers
■ Heat exchangers
■ Feedwater heaters
■ Air conditioners
■ Air coolers
Magnetic field
■ Heat exchangers
The UT beam is reflected by the
tube’s inner and outer walls.
Turbine body
The tube is
flooded
with water.
2 www.olympus-ims.com 3
MultiScan MS 5800 R™ System MultiScan MS 5800 R™ System
Tube Inspection with Tube Inspection with
Remote Field Testing (RFT) Magnetic Flux Leakage (MFL)
■ Boilers ■ Feedwater heaters
■ Feedwater heaters ■ Air coolers
■ Carbon steel heat exchangers ■ Carbon steel heat exchangers
Absolute response
4 www.olympus-ims.com 5
Accessories Complete Heat Exchanger Tubing Inspection Solution
Eddy Current Array Multiplexer MS 5800, MultiView, and TubePro Software: The Ultimate Combination.
• Features acquisition, analysis and reporting.
• Multiple technologies: ECT, RFT, NFT, MFL (all with array capabilities), IRIS.
• Offers advanced user-editable reporting featuring 2-D tube maps and impressive 3-D drawings.
• Has an easy-to-use interface with improved controls.
Example of MS5800 system with 4x 32-channel ECA probes connected through 2 ECA multiplexers.
The array technologies are valuable when high resolution or When used in combination with the MS5800 system and the
imagery is desired. The MultiView™ acquisition and analysis MultiView “C” option, one or two ECA multiplexer units enable
software features improved C-scan functionality for easy setup array technology with ECT, RFT, NFT, or MFL technologies. While E-123
1 1 N 1
1 5 10 15
1 5 10 15 20
and analysis in a virtually unlimited number of layouts. the majority of OmniScan® ECA probes can be connected to the 1 5 10 15 N
5 1 10 15 20 25 5
1 5 10 15 20 25
1 5 10 15 20 25
1 5 10 15 N 20 25 N
ECA multiplexer, Olympus provides the option of configuring the 1 5 10 N 15 20 25 30
10 1 5 10 15 20 25 10
1 5 15 20 25 30
1 5 10 15 20 25
LEGEND KEY
1 5 10 15 20 N 25 30
Tube Testing Array probes to your needs. 1 5 10 15 25
DESCRIPTION SYMBOL QTY
15 1 5 10 15 20 25 30 15 TUBE COUNT 1296(100%)
1 5 10 15 20 25
1 5 10 15 20 25 30 30-39.9% 4(0.31%)
1 5 10 15 20 25
40-49.9% 6(0.46%)
50-59.9% 11(0.85%)
25 1 5 10 15 20 25 25 60-69.9% 6(0.46%)
1 5 10 15 20 25 30
Maximum Number of Individual Sensors 1 5 10 15 20 25
70-79.9% 6(0.46%)
1 5 10 15 20 N 25 30 80-89.9% 7(0.54%)
1 5 10 15 20 25
1 5 10 15 20 30
90%-THRU
HRU
RU
U WA
WALL
WAL
WA 1(0.08%)
1 (0.0
08%)
Part Number Item Number Description 30
1 5 10 15 20 25
30
RSTR-PARTIAL
RST
RS
STR-PARTIA
ST
S TR-P
TR-PARTIAL
R-
R-PARTIA
R --PARTIAL
P
PART
PA
A
ARRT
TIIIA
AL
AL 0(0%)
0(0%
((0%)
%)
1 5 10 15 20 25 30
ECT RFT NFT MFL IRIS 1 5 10 15 20 25
OB
OBS-NO
O
OBS
BS-NO
BS--NO
S-NO
N
NOO DATA
DAT
D
DAAT
ATA 0(0%)
(0%)
1 5 10 15 20 25 30 PL
PLUGGED
P LUGGED
LUGGED
LUGGE
LU
UGG
UGG
G
GGED
GE
GGED
ED 0(0%)
0(
0(0%
0(0%)
(0%
35 1 N 5 10 15 20 25 35
1 5 10 15 20 25 N
1 5 10 15 20 N 25
1 N 10 15 20 25 30
1 5 10 15 20 25 N
1 5 10 15 N 20 25
1 5 10 15 20 25
MUX-PKG-MS U8780060 64 8 64 64 Not supported 1 N 10 N 15 20 25
45 1 5 N 15 20 45
channels (required) 1 5 10 15 20
1 N 10 15
48 1 5 48
MS 5800 Backpack
Each MS5800 system is currently delivered with a backpack
(20ED0074, U8764077), which provides your operational staff MultiView and TubePro
with maximum comfort and protection. The backpack, which The MultiView and TubePro software brochure details the advances in heat exchanger
was developed and tested in the field with the assistance of tubing inspection solutions from Olympus.
several service companies, also provides additional space to carry This document can be downloaded from the Olympus website.
calibration tubes, probes, or adaptors.
t $PNQMFUF)FBU
&YDIBOHFS
5VCJOH*OTQFDUJ Tube Inspection Probe Catalog
PO4PMVUJPO
t "DRVJTJUJPO
"O
BMZTJT
BOE
3FQPSUJOH
t "EWBODFE6TFS
MS 5800 Footswitch &EJUBCMF
3FQPSUJOH The Tube Inspection Probe Catalog features eddy current, magnetic flux leakage,
t .VMUJQMF5FDIOP
MPHZ TUBE INSPECTION
t &BTZUP6TF*OU
FSGBDF Probe
es and Accessories
The optional MS5800 Footswitch (TA-FSW-001, U8770248) remote field, near field, and IRIS ultrasonic probes and accessories, in addition to
provides productivity gains to individuals or two-person crews 920-239A-EN
related ordering information. This document can be downloaded from the Olympus
when recording data. With its field-proven, rugged design, it website.
enables the operator to remotely perform the majority of common
operations by programming several useful and configurable
functionalities in the MultiView software, without the need to
directly access the computer.
t &EEZ$VSSFOU
t &EEZ$VSSFOU"SSBZ
t 3FNPUF'JFME
t /FBS'JFME
t .BHOFUJD'MVY-FBL
BHF
t *3*46MUSBTPVOE
t "DDFTTPSJFT
920-149C-EN
66 www.olympus-ims.com 77
MultiScan MS 5800 Specifications
General Output voltage: Probe balancing:
20 Vp-p per generator (2 outputs) True electronic probe balancing
Power: 120 VAC or 220 VAC ±10%, automatic
selection, 48 Hz to 63 Hz Output current: 1 A (peak) Output voltage:
Real-time alarms: Eight independent alarms (raw 20 Vp-p per generator (2 outputs)
Size (excluding handle):
45 cm × 30 cm × 22 cm channels only) Output current: 1 A (peak)
(17.7 in. × 11.8 in. × 8.7 in.) Encoders: Analog output:
Weight: Maximum weight with all modules Two quadrature encoders and digital inputs X and Y components of the first input
installed: 12.8 kg (28.2 lbs) Remote Field Testing, Near Field, Real-time alarms: Eight independent alarms
Environment: –20°C to 45°C (-4 °F–117 °F) for (raw channels only)
and Magnetic Flux Leakage
ambient operation; –20°C to 70°C (-4 °F -158 °F) Encoders:
Probe inputs:
storage; 95% relative humidity, noncondensing Two quadrature encoders or digital inputs
Four independent inputs for RFT/NFT
Computer interface: Four independent inputs for MFL Ultrasonic IRIS Testing
100Base-T Fast Ethernet
RFT/NFT channels: Number of pulsers/receivers: One channel in
Eddy Current Testing 16 simultaneously pulse-echo mode
Probe inputs: Four independent differential (4 inputs x 4 frequencies);
System bandwidth: 0.5 MHz to 25 MHz
inputs, and up to 64 multiplexed inputs (16 time 64 in multiplexed mode for NFT (4 inputs x 16
time slots) and eight for RFT (4 inputs x 2 time Sampling rate: 8-bit, 100 MHz
slots) with MUX-PKG-MS (U8780060)
slots) Transducer frequencies: 1 MHz to 20 MHz
ECT channels:
16 simultaneously (4 inputs x 4 frequencies); 256 MFL channels: Pulse repetition rate: Up to 20 kHz
in super-multiplexed mode (with 16 time slots) Four simultaneously Dynamic gain (linear amplifier):
64 in multiplexed mode (4 inputs x 16 time slots) 70 dB, 1 dB steps
Number of frequencies:
Up to eight frequencies Number of frequencies: A-scan length: 32 to 8,092 points
Up to four frequencies (RFT only)
Frequency range: Pulse voltage: 50 V to 300 V, 1 V steps
Adjustable from 20 Hz to 6 MHz Frequency range:
Adjustable from 20 Hz to 250 kHz High-pass filter:
Acquisition rate: 40 kHz per channel (in None, 2 MHz, 5 MHz, 10 MHz
conventional mode); 14 kHz divided by the Acquisition rate:
40 kHz per channel (in conventional mode); Data-acquisition synchronization:
number of time slots (in multiplexed mode) Time, continuous, position, or external
14 kHz divided by the number of time slots (in
Supported probes: The universal connector multiplexed mode) Encoders:
supports all standard differential and absolute Two quadrature encoders and digital inputs
bobbin, impedance, transmit-receive, and Supported probes: Supports any differential
and absolute probes with a single exciter, dual (requires MultiView 6.1 or higher)
rotating probes.
exciters, dual pickup, near field, and magnetic
(Adaptor cable might be required.)
flux leakage.
Probe balancing: True electronic probe
(Adaptor cable might be required.)
balancing. A separate external reference probe is
not required for absolute channels.
3415, rue Pierre-Ardouin, Québec (Québec) G1P 0B3, Tel.: (1) 418-872-1155
For inquiries - contact 1109 78 Ave, Edmonton (Alberta) T6P 1L8
www.olympus-ims.com/contact-us
MS_5800_EN_201803 • Printed in the USA • P/N: 920-107-EN Rev. E