Sei sulla pagina 1di 4

The Future of Power System

Engineering & Operation – Today

Innovation
Automation
Collaboration

The ETAP 11 release represents our continued commitment shared


with clients and business partners to provide the most comprehensive
analytical solutions for the design and operation of power systems now,
New Features
and the energy technologies for tomorrow.
& Capabilities
This automated design and analysis software enables engineers and
managers to significantly increase their productivity by reducing the
amount of design and review man-hours.

As the industry’s market leader, ETAP delivers the future of power systems
engineering and operation - today.
Elements & Database Real-Time
Multi-Dimension Database Transformer Power System Monitoring & Simulation
• Lock & unlock element properties • Open-Delta transformer • Generation reserve monitoring
• 10 States to track equipment conditions • Three 1-phase transformer • Multi-state breaker monitoring & control
• Local SQL server connectivity • MVA rating based on first & second • Large system handling optimization
stage cooling • EPICS interface
Data Manager • Option to display Vector Groups
• View / edit Base & Revision Data Event Playback
differences Uninterruptable Power Supply - UPS • Playback of event views
• View equipment property differences • Parallel UPS connection modeling • Historical alarm database
• Display & filter study data • Option to control input PF
• Graphical management of data • Bypass switch modeling Intelligent Fast Load Shedding
• System islanding generator logic
Data Exchange - DataX Bus Duct • VFD load reduction control
• Bi-directional Excel data exchange • Graphical representation on the • Automatic generation of transient study
• Load Ticket for induction machines One-Line Diagram cases
• GIS handling of 1-phase systems • Bus duct length, construction type,
• PSS/E Raw data import & material Interchange Transaction Scheduling
• ETAP-SPEL interface • Transaction reports
Single Phase Source • Fuel cost schedule reports
Project Merge • 1-phase power grid modeling
• Multi-user management of project merge • 1-phase inverter modeling OPC Unified Architecture - UA Server
• Parallel ETAP project development • Console communication via WAN
• Self contained snapshots of the parent Photovoltaic Array • Thin client application
& branch projects • Performance adjustment coefficients • Secured access control
• Merge Base & Revision Data • Solar farm modeling • Interface to OPC UA & DA clients
• Solar irradiance based on location & time
Theme Manager • AC & DC system analysis Monitoring & Control Templates
• Display color coding based on: • Inverter dynamic modeling & operation • Thin client application for monitoring
- Standard modes & control
- Voltage level • Maximum Peak Power Tracking (MPPT) • Customizable Web-based interfaces
- Area • Extensive Manufacturer/Model library & technology
- Grounding (Solid, Low-Z, • P-V & I-V curves • Human Machine Interface (HMI)
High-Z, Ungrounded) template library
- Earthing (TT, TN, IT, NEC) Wind Turbine Generator - WTG • Web-based customizable HMI:
- Grounding by ground switch • WTG Manufacturer / Model library - SCADA views
• Display faulted buses by symbol or • New WTG & control models for WECC - WPF dashboards
color type 1, 2, 3, & 4 - Trending & forecasting
- Alarms & warnings
Multiple Language Support Variable Frequency Drive - VFD - Control & supervision
• Interface & Help File in four languages • Multi-input connection for 6-24 pulse - Energy consumption monitoring
• Localized output reports: • Sub-system modeling between VFD - Reporting & logging
- English, Spanish, Chinese, & motor - Geographical monitoring view
Japanese, Russian, • Rectifier & inverter control models
Portuguese, & German • Output voltage & frequency control Command & Control
• Frequency dependent modeling of • Remote control - enable & disable
sub-system commands
Induction Machine
• Adjustable speed drive operation • Control inhibition based on system
• PF & EFF at no-load & over-load
• Motor acceleration control schemes operational constraints
conditions
• Bypass switch for soft starter operation • Control inhibition based on switching
• Locked-Rotor current based on NEMA
MG1 Code Letter • Input PF control operations
• Option to calculate Xd” & Xd’ based on
Switching Devices Data Center Power Management
machine time constant
• Safety ground switch • Power panel monitoring
• Integrated operation with Switching • Parallel UPS operation
Libraries Management System • CO2 & energy management system
• Photovoltaic panel library • Supervisory control for real-time • PDU monitoring & control templates
• Wind turbine generator library switching operation
• GFI / RCD library
• Cable library with neutral, grounding /
protective (PE) conductors
• New Verified & Validated library data
Analysis Modules
Protective Device Coordination - Star Cable System Load Flow
• Automatic detection of protection zones • Cable Library with neutral, grounding / • Auto-Run load flow based on
• Automatic selection of coordination paths protective conductor (PE) system changes
• Protection & coordination zone viewer • Add auxiliary neutral & PE conductors • New toolbar to change & display
• Combine / Integrate multiple device curves to cables result units
• Ground & Neutral conductors • Damage curve for neutral & PE conductors • Report voltage in %, kV, V
damage curves • Report Power in MVA, kVA
• Cumulative Transformer Inrush current Cable Ampacity & Sizing - IEEE/NEC • Isolated 1-phase source modeling
• Enhanced Plot Options • IEEE 399, NFPA 70 (NEC), ICEA P54
• Cable sizing based on maximum or Unbalanced Load Flow
AC Arc Flash Analysis average phase operating current • Report voltage & power in multi-units
• Primary protective device identified • Reports in Crystal Reports & Excel • Open-Delta transformer modeling
• Current Limiting Fuse (CLF) modeling • Grounding conductor selection • Center-Tap transformer modeling
based on: • Cable ampacity & sizing for U/G • Three 1-phase transformer modeling
- IEEE 1584 equations • Isolated sub-systems with Voltage-Control
(Class L & RK1) Cable Ampacity & Sizing - IEC/BS source modeling
- Peak let-through curves • BS 7671, IEC 60364-5-52, • Isolated 1-phase source & system
- TCC Curve method IEC 60364-4-43 modeling
• LV transformer arc flash limit based on • Model Forms: BS & user-definable
impedance, voltage & current • Cable sizing based on harmonic effect Motor Acceleration
• Incident Energy plots for Ia & Ibf • Typical overcurrent device curves • VFD frequency control motor starting
• Enhanced display of results on the • Cable sizing based on maximum or • User-defined frequency and Volt/Hz as
one-line diagram average operating current functions of time
• Reports in Crystal Reports & Excel • Simulate voltage-boost effect at low
DC Arc Flash Analysis frequency during starting
• Maximum power method Protective Conductor Sizing - IEC/BS • Motor acceleration with VFD &
• Stokes & Oppenlander method • BS 7671, IEC 60364-5-54 soft starter
• Paukert method • PE thermal requirements & sizing
• Determine incident energy • Calculated or user-defined fault current & Harmonics
• Assess arc flash protection boundary fault clearing time • VFD harmonic modeling
• Customize arc flash labels • Reports in Crystal Reports & Excel • Calculate & report I*TB (Balanced)
• DC arc flash Result Analyzer • Consider leakage current & I*TR (Residual)
• UPS AC input & output modeling for
User-Defined Dynamic Model - UDM Electric Shock Calculation - IEC/BS harmonic orders
• Graphical model builder • BS 7671, IEC 60364-4-41, EN 50122 • PV Array modeling for harmonic orders
• Library of pre-defined UDM models to • TN-C, TN-S, TN-C-S, TT, & IT
create more complex models Earthing Types Transient Stability
• Compile & test directly from the • Electric shock requirements • Lumped Load UDM
UDM builder • Loop impedance & current calculation • New built-in IEEE standard exciters:
• Control element toolbars including transfer • Touch voltage calculation & evaluation - AC2A, AC7B, DC4B, ST1A, ST2A
blocks, input ports, output ports, etc. • Consider resistance to Ground / Earth • VFD dynamic modeling:
• Automatic UDM links to components • GFCI / RCCB protection - Rectifier, DC link, & inverter models
• Import & Export to Simulink® models • Reports in Crystal Reports & Excel - Voltage & frequency control models
• Create & edit models for Exciter, Governor, - Frequency control acceleration
Power System Stabilizer, & Lumped Load & operation
• UPS parallel operation modeling
Underground Raceway System • PV Array source modeling
• Intelligent rule-based alignment • Inverter source modeling
& spacing tools
• Automatic conduit distribution & spacing
• Uniform & non-uniform conduit
arrangements
• Utilize custom, NEC, or standard IEEE
rule-based spacing
• Wizard for creating raceways

New Features & Capabilities


© September 2011 Operation Technology, Inc.
etap.com
T 800.477.ETAP
T 949.900.1000

Operation Technology, Inc. B4-E11-0911-3

© 2011 Operation Technology, Inc. All rights reserved. Certain names and/or logos used
in this document may constitute trademarks, service marks, or trade names of Operation
Technology, Inc. Other brand and product names are trademarks of their respective holders.

Potrebbero piacerti anche