INSTRUCTION MANUAL –
DTR CATHODIC PROTECTION
D R A
IN3-MAY 13
2
- 2 0
Sheet 3 of 26
A Company
TABLE OF CONTENTS
INTRODUCTION: .................................................................................................................................................................. 3
PIPELINES TO BE PROTECTED: .................................................................................................................................... 3
REFERENCE CP DRAWINGS: ........................................................................................................................................... 4
PIPELINE COATING ............................................................................................................................................................ 4
BILLS OF QUANTITY: ......................................................................................................................................................... 4
HANDLING PROCEDURES FOR EQUIPMENT & MATERIALS ............................................................................ 4
FIELD TEST AND INSPECTION METHODS ................................................................................................................ 5
HEALTH, SAFETY & ENVIRONMENTAL PRECAUTIONS & MITIGATION MEASURES............................. 5
PRELIMINARY WORK ........................................................................................................................................................ 6
CHECK LIST & RECORD OF TEST RESULTS .............................................................................................................. 7
INSTALLATION PROCEDURE ......................................................................................................................................... 7
COMMISSIONING ................................................................................................................................................................. 9
MAINTENANCE MONITORING ....................................................................................................................................... 9
PROTECTION CRITERIA ................................................................................................................................................. 10
APPENDIX A ......................................................................................................................................................................... 11
D R A 2
IN AY 13
23-M
- 2 0
Sheet 4 of 26
A Company
INTRODUCTION:
This document provides the installation and commissioning details for the short isolated buried
pipework in the DTR area, located at the sales gas tie in point , which is part of the Gassi
Touill processing facilities , Algeria which is covered by a separate JGC order – PO 0-5353-
P-2187-001-B.
The Cathodic Protection system provided for the DTR pipework comprises of magnesium
ribbon anodes linearly placed along the pipelines in the same trench as the pipes, and
designed for a 25 year life.
PIPELINES TO BE PROTECTED:
D R A 3
IN AY 13
23-M
- 2 0
Sheet 5 of 26
A Company
REFERENCE CP DRAWINGS:
PIPELINE COATING:
BILLS OF QUANTITY:
D R A 4
IN AY 13
23-M
- 2 0
Sheet 6 of 26
A Company
Field-testing and inspection shall be carried out to ensure proper installation of the
CP equipment and facilities.
All testing and inspection shall be performed by qualified personnel to ensure high
quality system performance.
Inspections shall be carried out at various stages during the course of CP
installation.
General Inspection:
The following inspections shall be performed after each stage of installation works:
A visual inspection of all CP materials and equipment shall be performed to ensure
correct and proper installations in accordance with the project specification, approved
design document and drawings.
Inspections shall be performed to ensure that each CP component, materials,
equipment and facilities have not been damaged during or after each installation
stage. Any discrepancies shall be noted and necessary corrective actions shall be
taken.
All CP cables are to be checked for proper identification, terminal connections and
routing.
D R A 5
IN AY 13
23-M
- 2 0
Sheet 7 of 26
A Company
Installation of the zinc bracelet and chain anodes may involve working at height
and/or from boats as such the works shall be carried out strictly in accordance with
the applicable project work permits for working at height / from boats. Where required
only certified scaffolding, scissor lifts and lifting gear shall be used.
The supervisor shall inspect all Personal Protective Equipment (PPE) to confirm that it
is fit for purpose and appropriate for the task. Damaged or worn out PPE shall NOT
be used and shall be replaced before the works commence. As a minimum PPE shall
be comprised of the following;
Hard hat
Safety Glasses
Ear defenders (if needed)
Overalls
Gloves (of a type appropriate to the task in hand)
Safety boots
The supervisor shall inspect all tools and equipment to ensure that it is fit for purpose,
without damage or modification and is appropriate to the task in hand. Damaged
tools / equipment shall NOT be used and shall be replaced before the works
commence.
Throughout the works the supervisor and work team shall maintain vigilance for any
changing circumstances that could result in an unforeseen hazard, with particular
attention being paid to the activities of other work parties in the area that could
present a hazard.
If in any doubt the supervisor and/or any member of the work team shall stop the
works and ask for guidance from the Permit to Work issuing authority.
All packaging materials, off-cuts and other waste materials shall be collected and
disposed of in accordance with the on-site project waste management policy.
The above applies to all installation procedures.
PRELIMINARY WORK:
Prior to commencing installation, the following should be completed to the satisfaction
of the Client/Engineer/Main Contractor:
Check site for any hazards or obstructions that could delay installation and/or damage
anodes.
Remove all metallic waste / debris from the surface where anode installation is to be
carried out.
All materials shall be checked as received to ensure good condition, and laid aside in
a safe place until required.
D R A 6
IN AY 13
23-M
- 2 0
Sheet 8 of 26
A Company
Check list has been provided (see relevant test sheet in Appendix A) to facilitate the
recording and preservation of installation records and test results.
INSTALLATION PROCEDURE:
1) Big Fink Test Posts (7No), one each required at each of the isolation flanges
Each test post will be provided with a conduit that will be cast on a concrete surround
to allow for self-standing.
The location of the test post wrt the pipe is based upon site considerations; however it
is preferred to locate the test post close to the isolation flange and within 2-3 metres
from the pipe, if possible, however in a safe area.
The following cables will be traced to the conduit and be terminated inside the test
post:
Note that the magnesium anode cable and the cable from the
‘protected’/underground end of the pipe are linked together.
Likewise one of the two coupon cables are also linked to the protected section
of the pipe.
D R A 7
IN AY 13
23-M
- 2 0
Sheet 9 of 26
A Company
The reference electrode is soaked in a bucket of water for 15 minutes and the potential
difference against a portable (similar type) electrode is recorded.
This is then ready for installation. The reference electrode is to be located within 200-
300mm from the ‘protected’ pipe close to the isolation flange.
3) Coupon installation
The coupon must be again located close to the protected end of the pipe, within
300mm and close to the isolation flange. It is important to note that the coupon ‘steel’
face must face the pipe.
The magnesium is made available in coils. The ribbon anode is to be laid alongside
the pipe and on one side of the pipe. The anode will be located around 250mm from
the pipe and at a depth of 100mm below the invert land of the pipe.
The steel core within the magnesium ribbon must be exposed to make a cable
connection as well as extension to the magnesium ribbon. Refer drawings provided for
details.
5) Cable connection
Cable connection to the pipe will be thermite welded. Thermite weld will be
encapsulated using a
Cable connection to the magnesium anode will be made by connecting the
exposed core to the cable , using split bolt and bitumastic tape/ two part epoxy
putty encapsulation
Cable connection between magnesium anode lengths will be done likewise.
D R A 8
IN AY 13
23-M
- 2 0
Sheet 10 of 26
A Company
COMMISSIONING:
1) To start with, the anode is not connected to the pipe ( within test post)
2) Natural potentials are recorded at all of the 7 test post locations, using the permanent
reference electrode that is in place
3) Integrity of isolation to be checked at all the 7 locations using a standard DVM and
checking resistance across the isolation.
4) The anode is then connected to the pipe and the pipe to one of the coupon cable
7) Disconnect the coupon cable at the test post and record instant potentials.
MAINTENANCE MONITORING:
1) Record pipe to soil potentials at every test post after one month.
2) Record coupon to soil potentials at every test post after one month of commissioning
3) Record coupon OFF potentials at every test post after one month
D R A 9
IN AY 13
23-M
- 2 0
Sheet 11 of 26
A Company
PROTECTION CRITERIA:
D R A 10
IN AY 13
23-M
- 2 0
Sheet 12 of 26
A Company
APPENDIX A
D R A 11
IN AY 13
23-M
- 2 0
Sheet 13 of 26
A Company
D R A 12
IN AY 13
23-M
- 2 0
Sheet 14 of 26
FRENCH TRANSLATION
D R A
N
I 23-MA Y - 2 013
Sheet 15 of 26
Page 1 de 12
A Company
MANUEL D’INSTRUCTIONS –
PROTECTION CATHODIQUE DTR
D R A .
IN AY 13
23-M
- 2 0
Sheet 16 of 26
Page 2 de 12
A Company
INTRODUCTION : .................................................................................................................. 3
CANALISATIONS A PROTEGER : ........................................................................................ 3
RÉFÉRENCES PLANS PC : ................................................................................................... 3
REVÊTEMENT DE CANALISATION : .................................................................................... 3
DEVIS QUANTITATIFS : ........................................................................................................ 4
PROCÉDURES DE MANIPULATION DE L'ÉQUIPEMENT ET DES MATÉRIAUX : .............. 4
ESSAIS DE CHANTIER ET MÉTHODES D’INSPECTION : ................................................... 4
Instrument et équipement d'essai de chantier : .................................................................. 5
Inspection Générales : .......................................................................................................... 5
SANTÉ, SÉCURITÉ ET PRÉCAUTIONS ENVIRONNEMENTALES - MESURES DE
CORRECTION : ...................................................................................................................... 5
TRAVAIL PRÉLIMINAIRE : .................................................................................................... 6
PROCÉDURE D'INSTALLATION : ......................................................................................... 7
Les démarches suivantes décrivent la procédure d'installation par étape des divers
composants/matériaux de PC fournis : ............................................................................... 7
CONTROLE D’ENTRETIEN ................................................................................................... 9
CRITÈRES DE PROTECTION : ............................................................................................ 10
APPENDICE A...................................................................................................................... 11
D R A
IN3-MAY 13
2
- 2 0
Sheet 17 of 26
Page 3 de 12
A Company
INTRODUCTION :
Ce document fournit les détails d'installation et de mise en service pour la canalisation
enterrée d'isolement courte dans le secteur DTR, située au point de raccordement de
gazoduc de vente, qui fait partie des installations de traitement de Gassi Touil, Algérie ;
celles-ci sont couvertes par une commande distincte de JGC – PO 0-5353-P-2187-001-B.
Le système de Protection Cathodique (PC) fourni pour les canalisations DTR se compose
d’anodes de ruban de magnésium linéairement placées le long des canalisations dans le
même fossé que les conduites, et destiné à une vie de 25 ans.
CANALISATIONS A PROTEGER :
RÉFÉRENCES PLANS PC :
REVÊTEMENT DE CANALISATION :
D R A
IN3-MAY 13
2
- 2 0
Sheet 18 of 26
Page 4 de 12
A Company
DEVIS QUANTITATIFS :
Emballage et Expédition
Une protection appropriée sera assurée pour empêcher des dommages
mécaniques et une corrosion atmosphérique en transit et au site de travail.
L'équipement et le matériel seront complètement exempts d'eau, sec et seront
emballés pour empêcher tous dégâts pendant le levage, le transit ou le
déchargement.
Conservation et Stockage
L'équipement et les matériaux seront protégés pour résister au transit maritime
ou aérien, et à une période prolongée de stockage au site de travail.
L'équipement sera protégé pour sauvegarder contre tout environnement
défavorable, tel que l'humidité, la pluie, la poussière, la saleté, la boue de
sable, le sel, l'air et l'eau de mer.
Des essais de chantier et des inspections seront effectués pour assurer l'installation
correcte de l'équipement de PC et leurs aménagements.
Tous les essais et inspections seront réalisés par un personnel qualifié pour
s’assurer d’une performance du système de haute qualité.
Des inspections seront effectuées à diverses étapes pendant l'installation de PC.
D R A
IN3-MAY 13
2
- 2 0
Sheet 19 of 26
Page 5 de 12
A Company
Inspection Générales :
Les inspections suivantes seront effectuées après chaque étape de travaux
d’installation :
Une inspection visuelle de tous les matériaux et équipements de PC sera effectuée
pour assurer des installations correctes et appropriées selon les spécifications de
projet, le document de conception approuvé et les plans.
Des inspections seront effectuées pour s'assurer que chaque composant, matériaux,
équipements et installations de PC n'ont pas été endommagés pendant ou après
chaque étape d'installation. Toute anomalie sera notée et les rectifications
nécessaires seront prises.
Tous les câbles de PC doivent être examinés pour s’assurer de l'identification
correcte, les connexions aux bornes et le cheminement.
D R A
IN3-MAY 13
2
- 2 0
Sheet 20 of 26
Page 6 de 12
A Company
Casque de protection
Lunettes de Sécurité
Protège-oreilles (si nécessaire)
Bleus de travail
Gants (de type convenant à la tâche en main)
Bottes de sécurité
Le contremaitre inspectera tous les outils et équipements pour s'assurer qu'ils sont
adaptés au besoin, sans dommages ou modifications et conviennent à la tâche en
main. Des outils/équipements endommagés ne seront PAS utilisés et seront
remplacés avant le début des travaux.
Pendant la durée des travaux, le contremaitre et l'équipe de travail seront vigilants à
toutes circonstances changeantes qui pourraient avoir comme conséquence un
risque imprévu, en payant particulièrement attention aux activités d'autres équipes de
travail dans le secteur qui pourraient présenter un risque
Au moindre doute le contremaitre et/ou n'importe quel membre de l'équipe de travail
arrêteront les travaux et demanderont conseil auprès des autorités émettrices de
Permis-de-travail.
Tous les matériaux d'emballage, chutes et autres déchets seront rassemblés et
débarrassés selon la politique de gestion des déchets de projet sur place.
Les conditions ci-dessus s'appliquent à toutes les procédures d'installation.
TRAVAIL PRÉLIMINAIRE :
Avant de commencer l’installation, les points suivants seront completés à la
satisfaction du client/de l’ingénieur/de l’entrepreneur principal :
Examiner le site pour déceler tous risques ou obstructions qui pourraient retarder
l’installation et/ou endommager les anodes.
Retirer tous les déchets/débris métalliques de la surface où l'installation d'anodes doit
être effectuée.
Tous les matériaux seront vérifiés comme reçu pour assurer leur bonne condition, et
mis de côté dans un endroit sûr jusqu'à leur emploi.
D R A
IN3-MAY 13
2
- 2 0
Sheet 21 of 26
Page 7 de 12
A Company
Une liste de contrôle est fournie (voir le bordereau de contrôle approprié - appendice
A) pour faciliter l'enregistrement et la conservation des rapports d'installation et des
résultats d'essai.
PROCÉDURE D'INSTALLATION :
Les démarches suivantes décrivent la procédure d'installation par étape des divers
composants/matériaux de PC fournis :
1) Boitiers de mesure Big Fink (7Nos), une à chacune des brides d’isolement.
Chaque boîtier de mesure, équipé d’un conduit, sera encastré dans une base de béton
lui permettant d’être auto-porteur.
L'emplacement du boîtier de mesure par rapport à la canalisation est basé sur des
considérations de site ; cependant on préfèrera localiser le boîtier de mesure près de
la bride d’isolement et à moins de 2 ou 3 mètres de la canalisation, si possible, mais
néanmoins dans un secteur sûr.
Les câbles suivants seront menés vers le conduit et seront terminés à l'intérieur du
boîtier de mesure :
D R A
IN3-MAY 13
2
- 2 0
Sheet 22 of 26
Page 8 de 12
A Company
3) Installation du Coupon
L’anode ruban de magnésium est livrée sur bobine. L’anode ruban doit être placée le
long de et d’un côté de la canalisation. L'anode sera placée à une distance de 250mm
de la canalisation et à une profondeur de 100mm au-dessous de radier de la
canalisation.
L’âme en acier du ruban de magnésium doit être exposée pour faire un raccord de
câble ainsi qu'une extension sur le ruban de magnésium. Voir les plans pour plus de
détails.
5) Connexion de câbles
D R A
IN3-MAY 13
2
- 2 0
Sheet 23 of 26
Page 9 de 12
A Company
MISE EN SERVICE :
CONTROLE D’ENTRETIEN :
D R A
IN3-MAY 13
2
- 2 0
Sheet 24 of 26
Page 10 de 12
A Company
CRITÈRES DE PROTECTION:
Un des critères suivants doit être satisfait (selon la directive NACE 0169 la plus
récente) :
D R A
IN3-MAY 13
2
- 2 0
Sheet 25 of 26
Page 11 de 12
A Company
APPENDICE A
D R A
IN3-MAY 13
2
- 2 0
Sheet 26 of 26
Page 12 de 12