Sei sulla pagina 1di 9

SLAB DESIGN

DESIGN OF ONE-WAY SLAB

Given: GUIDELINES:
live load: 3.8 kPa fc' = 27.5 mPa 1. Fill-up only colored cells with their corresponding values.
fy = 415 mPa L: 1.2 m slab length
floor finish: 1.1 kPa f = 0.9 cover = 20 mm concrete stress and strain
ceiling finish: 0.24 kPa b1 = 0.85 type of loading
mech. duct allowance: 0.25 kPa conc. unit wt.= 23.5 kN/m3 miscellaneous dead loads
electrical load: 0 kPa rebars diameter and concrete cover
partition load: 0 kPa using 12 mm rebars constants for computing h and Mu.
miscellaneous load: 1 kPa Ad = 113.10 mm2 2. Avoid editing non-colored cells for it may cause unreasonable design.
3. For the design of sections having different moments, just replace tha value of
denominator for Mu for that corresponding section.
Solution: 4. Checking computations using calculator may will not match with the computer's
minimum slab thickness, h computations due to rounding-off numbers. Computer uses complete decimal
L ( 1.2 ) ( 1000 ) numbers and exact values.
h= = = 42.86 mm
28 28
say h = 50 mm

assume effective depth, d


d = h - cover - half of bar diameter
= 50 - 20 - 6
= 24 mm

Dead Loads:
slab self-weight = h x conc. unit wt.= ( 0.05 ) ( 23.5 ) = 1.18 kPa
floor finish = 1.1 kPa
ceiling finish = 0.24 kPa
mech. duct allowance = 0.25 kPa
electrical load = 0 kPa
partition load = 0 kPa
miscellaneous loads = 1 kPa

3.77 kPa
Factored Load:
WUDL= 1.2 (DL) = 1.2 ( 3.77 ) = 4.518 kPa
WULL= 1.6 (LL) = 1.6 ( 3.8 ) = 6.08 kPa
WU = WUDL + WULL = 10.598 kPa

At END 1 :

Wu L 2 ( 10.598 ) ( 1.2 )2
Mu = = = 1.5261 kN-m
10 10

MU 1.526 x 10e6
Rn = = = 2.944 MPa
f b d12 0.90 x 1000 x (24 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 27.5 ) 2 x 2.944


= x 1- 1- = 0.00761
415 0.85 x 27.5

1.4 fc' 1.4 27.5


rmin = or = or
fy 4 fy 415 4 x 415
= 0.00337349 or 0.00315906 Therefore, use 0.00337

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 27.5) 600
= x = 0.02123
415 600 + 415

when rmin < r < rmax


Therefore, use 0.00761 for As

As = r b d
= ( 0.00761 ) ( 1000 ) ( 24 )
= 182.578792 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 619.459 mm
As 182.578792

say S = 610 mm

Smax = 3h = 3 ( 50 ) = 150 mm or 450 mm


Therefore, Smax = 150 mm

S > Smax Therefore S = 150 mm

At MIDSPAN :
Wu L 2 ( 10.598 ) ( 1.2 )2
Mu = = = 0.9538 kN-m
16 16

MU 0.954 x 10e6
Rn = = = 1.840 MPa
fbd 1
2
0.90 x 1000 x (24 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 27.5 ) 2 x 1.840


= x 1- 1- = 0.00462
415 0.85 x 27.5

1.4 fc' 1.4 27.5


rmin = or = or
fy 4 fy 415 4 x 415
= 0.00337349 or 0.00315906 Therefore, use 0.00337

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 27.5) 600
= x = 0.02123
415 600 + 415

when rmin < r < rmax


Therefore, use 0.00462 for As

As = f b d
= ( 0.00462 ) ( 1000 ) ( 24 )
= 110.959533 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 1019.29 mm
As 110.959533

say S = 1010 mm

Smax = 3h = 3 ( 50 ) = 150 mm or 450 mm


Therefore, Smax = 150 mm

S > Smax Therefore S = 150 mm

At END 2 :

Wu L 2 ( 10.598 ) ( 1.2 )2
Mu = = = 1.5261 kN-m
10 10

MU 1.526 x 10e6
Rn = = = 2.944 MPa
f b d12 0.90 x 1000 x (24 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 27.5 ) 2 x 2.944


= x 1- 1- = 0.00761
415 0.85 x 27.5

1.4 fc' 1.4 27.5


rmin = or = or
fy 4 fy 415 4 x 415
= 0.00337349 or 0.00315906 Therefore, use 0.00337

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 27.5) 600
= x = 0.02123
415 600 + 415

when rmin < r < rmax


Therefore, use 0.00761 for As

As = f b d1
= ( 0.00761 ) ( 1000 ) ( 24 )
= 182.578792 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 619.459 mm
As 182.578792

say S = 610 mm

Smax = 3h = 3 ( 50 ) = 150 mm or 450 mm


Therefore, Smax = 150 mm

S > Smax Therefore S = 150 mm


temperature bars :

Ast = 0.0018 bh
= 0.0018 ( 1000 ) ( 50 )
= 90 mm 2

Ad (1000) ( 113.10 ) ( 1000 )


sst = = = 1257 mm
Ast 90

say S = 1250 mm

Smax = 5h = 5 ( 50 ) = 250 mm or 450 mm


Therefore, Smax = 250 mm

S > Smax Therefore S = 250 mm

DESIGN OF TWO-WAY SLAB

Given: RESULTING TABLE


short side A: 2.6 m fc' = 28 mPa
Middle Strip Column Strip
long side B: 3.6 m fy = 420 mPa
f = 0.9 SLAB
f = 0.85 As (mm2) S (mm) As (mm2) S (mm)
LOADS:
live load: 1.9 kPa conc. unit wt.= 23.5 kN/m3
cont. edge 280.000 220 186.667 220
floor finish: 1.1 kPa CA = 0.061 using 12 mm rebars
CADL = short span midspan 280.000 220 186.667 220
ceiling finish: 0.24 kPa 0.036 cover = 20 mm
mech. duct allowance: 0 kPa CALL = 0.049
CB = Ad = 113.10 disc. edge 93.333 220 62.222 220
electrical load: 0.25 kPa 0.036
partition load: 0 kPa CBDL = 0.013
CBLL = cont. edge 240.000 220 160.000 220
miscellaneous load: 1 kPa 0.016

long span midspan 240.000 220 160.000 220


SOLUTION:
disc. edge 80.000 220 53.333 220
2.60
ratio m = = 0.722 > 0.500 Two-way Slab!
3.60
GUIDELINES:
2 ( 2.60 + 3.60 ) (1000) 1. Fill-up only colored cells with their corresponding values.
h= = 68.889 mm slab dimensions
180 concrete stress and strain
say h = 110 mm > hmin = 90 mm ok! 110 type of loading
miscellaneous dead loads
d1 = h - (cover) - (rebar f) = 84 mm rebars diameter and concrete cover
d2 = h - (cover) - (rebar f) - (half of rebar f) = 72 mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
Dead Loads: 3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
slab self-weight = h x conc. unit wt.= ( 0.11 ) ( 23.5 ) = 2.59 kPa beam dimensions.
floor finish = 1.1 kPa 4. Checking computations using calculator may will not match with the computer's
ceiling finish = 0.24 kPa computations due to rounding-off numbers. Computer uses complete decimal
mech. duct allowance = 0 kPa numbers and exact values.
electrical load = 0.25 kPa 5. Having discontinuous edge will depend upon the case of the slab.
partition load = 0 kPa As seen on the table, depends on slab's case.
miscellaneous loads = 1 kPa

5.18 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.2( 5.18 ) = 6.210 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 9.250 kPa

Solving for Moments:


A. Short Span, Middle Strip
at continuous edge
MA = (Wu) (CA) (A2)
= 3.814 kN-m

at midspan
MADL = (WuDL) (CADL) (A2)
= 1.511 kN-m
MALL = (WuLL) (CALL) (A2)
= 1.007 kN-m
MA = MADL + MALL = 2.518 kN-m

B. Long Span, Middle Strip


at continuous edge
MB = (Wu) (CB) (B2)
= 4.316 kN-m

at midspan
MBDL = (WuDL) (CBDL) (B2)
= 1.046 kN-m
MBLL = (WuLL) (CBLL) (B2)
= 0.630 kN-m
MB = MBDL + MBLL = 1.677 kN-m

Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 3.814 x 10e6
Rn = = = 0.601 MPa
f b d12 0.90 x 1000 x (84 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 0.601
= x 1- 1- = 0.00145
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin > r < rmax


Therefore, use 0.00333 for As

f b d1
= ( 0.00333 ) ( 1000 ) ( 84 )
= 280 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 403.929 mm
As 280

say S = 400 mm

Smax = 2h = 2 ( 110 ) = 220 mm or 450 mm


Therefore, Smax = 220 mm

S > Smax Therefore S = 220 mm

at midspan
MA 2.518 x 10e6
Rn = = = 0.397 MPa
f b d12 0.90 x 1000 x (84 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 0.397
= x 1- 1- = 0.00095
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin > r < rmax


Therefore, use 0.00333 for As

As = f b d1
= ( 0.00333 ) ( 1000 ) ( 84 )
= 280 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 403.929 mm
As 280

say S = 400 mm

Smax = 2h = 2 ( 110 ) = 220 mm or 450 mm


Therefore, Smax = 220 mm

S > Smax Therefore S = 220 mm

B. Long Span, Middle Strip


at continuous edge
MB 4.316 x 10e6
Rn = = = 0.925 MPa
fbd 2
2
0.90 x 1000 x (72 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 0.925
= x 1- 1- = 0.00225
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin > r < rmax


Therefore, use 0.00333 for As

As = f b d2
= ( 0.00333 ) ( 1000 ) ( 72 )
= 240 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 471.25 mm
As 240

say S = 470 mm

Smax = 2h = 2 ( 110 ) = 220 mm or 450 mm


Therefore, Smax = 220 mm

S > Smax Therefore S = 220 mm

at midspan
MB 1.677 x 10e6
Rn = = = 0.359 MPa
fbd 2
2
0.90 x 1000 x (72 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 0.359
= x 1- 1- = 0.00086
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin > r < rmax


Therefore, use 0.00333 for As

As = f b d2
= ( 0.00333 ) ( 1000 ) ( 72 )
= 240 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 471.25 mm
As 240

say S = 470 mm

Smax = 2h = 2 ( 110 ) = 220 mm or 450 mm


Therefore, Smax = 220 mm

S > Smax Therefore S = 220 mm


DESIGN OF TWO-WAY SLAB
with INTERPOLATION

Given: RESULTING TABLE


short side A: 2.2 m fc' = 28 mPa
Middle Strip Column Strip
long side B: 3.7 m fy = 420 mPa
f = 0.9 SLAB
f = 0.85 As (mm2) S (mm) As (mm2) S (mm)
LOADS:
live load: 1.9 kPa conc. unit wt. = 23.5 kN/m3
cont. edge 210.838 140 140.558 140
floor finish: 1.1 kPa CA = 0.085 using 12 mm rebars
CADL = short span midspan 146.667 140 97.778 140
ceiling finish: 0.24 kPa 0.05 cover = 20 mm
mech. duct allowance: 0 kPa CALL = 0.063
CB = Ad = 113.10 disc. edge 70.279 140 46.853 140
electrical load: 0.25 kPa 0.015
partition load: 0 kPa CBDL = 0.009
CBLL = cont. edge 139.257 140 92.838 140
miscellaneous load: 1 kPa 0.011
long span midspan 106.667 140 71.111 140
SOLUTION:
disc. edge 46.419 140 30.946 140
2.20
ratio m = = 0.595 > 0.500 Two-way Slab!
3.70
GUIDELINES:
2 ( 2.20 + 3.70 ) (1000) 1. Fill-up only colored cells with their corresponding values.
h= = 65.556 mm slab dimensions
180 concrete stress and strain
say h = 70 mm < hmin = 90 mm use h = 90mm type of loading
miscellaneous dead loads
d1 = h - (cover) - (rebar f) = 44 mm rebars diameter and concrete cover
d2 = h - (cover) - (rebar f) - (half of rebar f) = 32 mm constants from the table of values
2. Avoid editing non-colored cells for it may cause unreasonable design.
Dead Loads: 3. Give the exact dimensions of the slab. Don't forget to subtract the supporting
slab self-weight = h x conc. unit wt.= ( 0.07 ) ( 23.5 ) = 1.65 kPa beam dimensions.
floor finish = 1.1 kPa 4. Checking computations using calculator may will not match with the computer's
ceiling finish = 0.24 kPa computations due to rounding-off numbers. Computer uses complete decimal
mech. duct allowance = 0 kPa numbers and exact values.
electrical load = 0.25 kPa 5. Having discontinuous edge will depend upon the case of the slab.
partition load = 0 kPa As seen on the table, depends on slab's case.
miscellaneous loads = 1 kPa

4.235 kPa
Factored Load:
WUDL = 1.2 (DL) = 1.6( 4.24 ) = 5.082 kPa
WULL = 1.6 (LL) = 1.6 ( 1.9 ) = 3.04 kPa
WU = WUDL + WULL = 8.122 kPa

Solving for Moments:


A. Short Span, Middle Strip
at continuous edge
0.60 0.085
0.595 CA
0.55 0.089

( 0.6 - 0.595 ) 0.085 - CA


=
( 0.6 - 0.55 ) ( 0.085 - 0.089 )
Therefore, CA = 0.08543243
MA = (Wu) (CA) (A2)
= 3.358 kN-m

at midspan
for DL: 0.6 0.05
0.595 CADL
0.55 0.053

( 0.6 - 0.595 ) 0.05 - CADL


=
( 0.6 - 0.55 ) ( 0.05 - 0.053 )
Therefore, CADL = 0.05032432
MADL = (WuDL) (CADL) (A2)
= 1.238 kN-m

for LL: 0.6 0.062


0.595 CALL
0.55 0.067

( 0.6 - 0.595 ) 0.062 - CALL


=
( 0.6 - 0.55 ) ( 0.062 - 0.067 )
Therefore, CALL = 0.06254054
MALL = (WuLL) (CALL) (A2)
= 0.920 kN-m

MA = MADL + MALL = 2.158 kN-m

B. Long Span, Middle Strip


at continuous edge
0.60 0.015
0.595 CB
0.55 0.011

( 0.6 - 0.595 ) 0.015 - CB


=
( 0.6 - 0.55 ) ( 0.015 - 0.011 )
Therefore, CB = 0.01456757
MB = (Wu) (CB) (B2)
= 1.620 kN-m

at midspan
for DL: 0.6 0.009
0.595 CBDL
0.55 0.007

( 0.6 - 0.595 ) 0.009 - CBDL


=
( 0.6 - 0.55 ) ( 0.009 - 0.007 )
Therefore, CBDL = 0.00878378
MBDL = (WuDL) (CBDL) (B2)
= 0.611 kN-m

for LL: 0.6 0.011


0.595 CBLL
0.55 0.009

( 0.6 - 0.595 ) 0.011 - CBLL


=
( 0.6 - 0.55 ) ( 0.011 - 0.009 )
Therefore, CBLL = 0.01078378
MBLL = (WuLL) (CBLL) (B2)
= 0.449 kN-m

MB = MBDL + MBLL = 1.060 kN-m

Strength Design:
A. Short Span, Middle Strip
at continuous edge
MA 3.358 x 10e6
Rn = = = 1.927 MPa
f b d12 0.90 x 1000 x (44 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 1.927
= x 1- 1- = 0.00479
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin < r < rmax


Therefore, use 0.00479 for As

As = f b d1
= ( 0.00479 ) ( 1000 ) ( 44 )
= 210.837672 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 536.432 mm
As 210.837672

say S = 530 mm

Smax= 2h = 2 ( 70 ) = 140 mm or 450 mm


Therefore, Smax = 140 mm

S > Smax Therefore S = 140 mm

at midspan
MA 2.158 x 10e6
Rn = = = 1.239 MPa
fbd 1
2
0.90 x 1000 x (44 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 1.239
= x 1- 1- = 0.00303
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
0 600 + 420

when rmin > r < rmax


Therefore, use 0.00333 for As

As = f b d1
= ( 0.00333 ) ( 1000 ) ( 44 )
= 146.666667 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 771.136 mm
As 146.666667

say S = 770 mm

Smax = 2h = 2 ( 70 ) = 140 mm or 450 mm


Therefore, Smax = 140 mm

S > Smax Therefore S = 140 mm

B. Long Span, Middle Strip


at continuous edge
MB 1.620 x 10e6
Rn = = = 1.758 MPa
f b d22 0.90 x 1000 x (32 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 1.758
= x 1- 1- = 0.00435
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin < r < rmax


Therefore, use 0.00435 for As

As = f b d2
= ( 0.00435 ) ( 1000 ) ( 32 )
= 139.256778 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 812.169 mm
As 139.256778

say S = 810 mm

Smax= 2h = 2 ( 70 ) = 140 mm or 450 mm


Therefore, Smax = 140 mm

S > Smax Therefore S = 140 mm

at midspan
MB 1.060 x 10e6
Rn = = = 1.150 MPa
fbd 2
2
0.90 x 1000 x (32 )2

0.85 fc' 2 Rn
r = x 1- 1-
fy 0.85 fc'

(0.85)( 28 ) 2 x 1.150
= x 1- 1- = 0.00281
420 0.85 x 28.0

1.4 fc' 1.4 28


rmin = or = or
fy 4 fy 420 4 x 420
= 0.00333333 or 0.0031497 Therefore, use 0.00333

(0.75)(0.85) f1 fc' 600


rmax = x
fy 600 + fy
(0.75)(0.85)( 0.85) ( 28) 600
= x = 0.02125
420 600 + 420

when rmin > r < rmax


Therefore, use 0.00333 for As

As = f b d2
= ( 0.00333 ) ( 1000 ) ( 32 )
= 106.666667 mm2

using 12 mm bars
Ad (1000) ( 113.10) (1000)
S= = = 1060.31 mm
As 106.666667
say S = 1060 mm

Smax= 2h = 2 ( 70 ) = 140 mm or 450 mm


Therefore, Smax = 140 mm

S > Smax Therefore S = 140 mm