.40(Tip) .

40(Tip)
.40 .40
.40 .40

LOSA LOSA .20 LOSA LOSA .20 ESPECIFICACIONES TECNICAS


CUADRO DE COLUMNAS
TIPO C-1
PISO

2Ø3/4"
.40 1Ø5/8"

DETALLE DE
COLUMNAS .35
1º, 2º,3º, PISO
ESC. 1/20
2Ø3/4"

1Ø5/8"
3.00 3.00
ACERO 4 Ø 3/4" 2 Ø 5/8"

Ø 3/8": 1@0.05, 6@0.10,


ESTRIBAJE 3@0.15, Rto.@0.20

LOSA LOSA .20 LOSA LOSA .20

VP .20 VP .20
LONGITUD DE TRASLAPE PARA COLUMNAS Y VIGAS DE CONFINAMIENTO (NORMA E-070)
.60
TRASLAPES
Lt
db (cm)

Le
85
Ø 3/4"

Ø 5/8" 75

Ø 1/2" 60

Ø 3/8" 45

3.60 3.60 12 mm 55

Ø5/8" Ø5/8"

Le

Ø3/4" Ø3/4"

.60

LOSA LOSA .20 LOSA LOSA .20

VP .20
UNIONES TIPICAS DE VIGAS
CON COLUMNAS (INTERMEDIO)
ESC. 1/25

ESTRIBOS ADICIONALES
Ø3/8"@.20

3.80

NPT : +0.15
NFP : +0.10
NTN : ±0.00 .15

.60

PROPIETARIO: FIRMA
INGENIEROS CONSTRUCTORES DEL FUTURO S,A,C
Ø(a) Ø(b)
.60 PROYECTO:
CONSTRUCCIÓN CASA VECINAL Nº 4 CONDE DE LEMOS
N.F.C = 1.20 m

E-01
SOLADO PLANO:

DETALLES CIMENTACCION - COLUMNAS


PROFESIONAL RESPONSABLE:

ING. LEONEL CORTEZ MEZA CIP. N° XXXXX


ESPECIALIDAD: ESCALA: DIBUJO: FECHA:

ESTRUCTURAS NOVIEMBRE 2018