INFRARED HEATERS

Similar to the sun, short-wave infrared radiation heats the objects without heating the air.
Once objects (or walls) are penetrated with heat, they can also reradiate and heat other objects.
Infrared radiation heats through fog or wind.
Infrared radiation runs straight, on the contrary hot air flows upwards.

Infrared heaters are an excellent solution for:


^ Heating objects, bodies or walls indoors and outdoors.
^ Drying plaster walls. Infrared heat penetrates the wall and evaporates the humidity of the wall from inside.
On the contrary an airflow heater creates a dry surface which traps the humidity into the wall.
^ Heating objects or limited indoor spaces. On the contrary hot air is quickly disperded in the room.
^ Saving energy, because less energy is required for achieving the same heating effect.

INFRARED HEATERS AIRFLOW HEATERS


HEAT OBJECTS HEAT AIR (AND OBJECTS)

SIDE VIEW

XL 9 or XL 91 AIRFLOW HEATER

TOP VIEW

25
INFRARED OIL FIRED HEATERS
HYBRID CORDLESS DIESEL
OIL

YOUTUBE VIDEO

Ventilation of the room is necessary to prevent a deficiency in oxygen supply.

DC 61 PATENTED
^ It works with a cord and tension (110-240 V) or cordless
with lithium battery (14 V)
^ 14 V only the highest electrical safety
^ Equipped with Master Lithium Battery BAT6
^ On board power adapter valid from 110 V to 220 V AC included
^ Low noise
^ Infrared heating (short wave)
^ No air flow
^ Electronic flame control with photocell
^ Post-ventilation
^ Standard oil level indicator
60 MINUTES 4 HOURS ^ ILME socket for remote thermostat: analog or digital
CHARGE RUN-TIME ^ Suction filter and inlet filter
^ Snorkel
^ Overheat thermostat
^ Anti-tilt switch

OPTIONAL ACCESSORIES:

6Ah Master Master battery Analog thermostat Digital thermostat


lithium battery pack charger TH5 with cable THD with 5 m cable
pack: 3 m - 4150.109 4150.106
4 hours run-time. 10 m - 4150.112
More than 1000
recharges.

SPECIFICATIONS DC 61 T Ambient 20°C 0,5 m 1m 1,5 m


kW 17 DC 61 110°C 50°C 20°C
Heating power Btu/h 58.000
kcal/h 14.600
Fuel consumption kg/h 1,35
Fuel autonomy h 7
Thermostat control analog or digital
Electric power kW 0,2
Power supply V 220-240*
Frequency Hz 50
Rated current A 1
Tank capacity l 11
Product size (l x w x h) mm 560 x 345 x 575
Box size (l x w x h) mm 600 x 380 x 580
Net/gross weight kg 19/21
Pallet pcs 16
* 110 V available

26
INFRARED OIL FIRED HEATERS
XL 61 DIESEL
OIL

Ventilation of the room is necessary to prevent a deficiency in oxygen supply.

XL 61
PATENTED
^ Low noise
^ Infrared heating (short wave)
^ No air flow
^ Electronic flame control with photocell
^ Post-ventilation
^ Standard oil level indicator
^ ILME socket for remote thermostat: analog or digital
^ Suction filter and inlet filter
^ Snorkel
^ Overheat thermostat
^ Anti-tilt switch

XL 61 WITH TROLLEY DISPLAY AND SOCKET FOR


REMOTE THERMOSTAT

OPTIONAL ACCESSORIES:

Trolley Manometer Analog thermostat Digital thermostat


4201.159 4201.187 TH5 with cable THD with 5 m cable
3 m - 4150.109 4150.106
10 m - 4150.112

SPECIFICATIONS XL 61 T Ambient 20°C 0,5 m 1m 1,5 m


kW 17 XL 61 110°C 50°C 20°C
Heating power Btu/h 58.000
kcal/h 14.600
Fuel consumption kg/h 1,35
Fuel autonomy h 7
Thermostat control analog or digital
Electric power kW 0,2
Power supply V 220-240*
Frequency Hz 50
Rated current A 0,85
Tank capacity l 11
Product size (l x w x h) mm 560 x 345 x 575
Box size (l x w x h) mm 600 x 380 x 580
Net/gross weight kg 19/21
Pallet pcs 16
* 110 V available

27
INFRARED OIL FIRED HEATERS
XL 9 SR AND XL 91 DIESEL
OIL

XL 9 XL 91
Ventilation of the room is necessary to prevent a deficiency in oxygen supply.

^ Low noise
XL 9 SR ^ Infrared heating (short wave)
PATENTED ^ No air flow
^ Electronic flame control with photocell
^ Post-ventilation
^ Oil level indicator
^ Optional room thermostat
^ Oil pump filter, suction filter and inlet filter
^ Snorkel (XL 91)
^ Adjustable direction/Tilting
^ Trolley included

XL 91
PATENTED

OPTIONAL ACCESSORIES:

Fuel pre-heater Analog thermostat Digital thermostat Manometer


4031.120 TH5 with cable THD with 5 m cable 4109.435
3 m - 4150.109 4150.106
10 m - 4150.112 (for XL 91 only)

SPECIFICATIONS XL 9 SR XL 91
kW 29 43 29 43
Heating power Btu/h 99.300 146.900 99.300 146.900
kcal/h 25.000 37.000 25.000 37.000
Fuel consumption kg/h 2,3 3,37 2,3 3,37
Fuel autonomy h 21 14 21 14
Thermostat control analog analog or digital
Electric power kW 0,16 0,19
Power supply V 220-240* 220-240*
Frequency Hz 50 50
Rated current A 0,7 0,7
Tank capacity l 60 60
Product size (l x w x h) mm 1070 x 700 x 980 710 x 970 x 990
Box size (l x w x h) mm 1200 x 750 x 1130 1030 x 750 x 1190
Net/gross weight kg 69/85 69/85
Pallet pcs 1 1
* 110 V available

28
INFRARED ELECTRIC HEATERS ELECTRIC

TS 3A
LONG WAVE

HALL 1500 ^ No noise


SHORT WAVE ^ Infrared heating
^ No air flow
^ Instant heat
^ No oxygen consumption
^ No fumes, no dust, no odours, no humidity
^ 100% efficiency
^ Life of the lamps: 5.000 hours
^ Not blinding golden lamps

HALL 3000
SHORT WAVE T Ambient 20°C 0,5 m 1m 1,5 m 2m
TS 3 70°C 45°C 35°C 30°C
HALL 1500 70°C 45°C 35°C 28°C
THALL 3000 85°C 50°C 40°C 30°C

OPTIONAL ACCESSORIES:

Stand for HALL 1500


4012.321

HALL 1500 HALL 3000 TS 3A

SPECIFICATIONS TS 3A HALL 1500 HALL 3000


kW 0,8 - 1,6 - 2,4 1,5 1,5/3,0
Heating power Btu/h 2.700 - 5.500 - 8.200 5.100 5.100-10.200
kcal/h 690 - 1.380 - 2.070 1.290 1.290-2.580
Infrared radiation long wave short wave short wave
Power supply V/Hz 220-240/50 220-240/50 220-240/50
Rated current A 10,5 6,5 13,0
Switch on/off yes yes yes
Insulating class 1 1 1
Lamp ceramic infrared gold gold
Lamp life h no limits 5000 5000
Approximate area m2 8 6 8
Cable HØ7 HØ7 HØ7
Product size (l x w x h) mm 398 x 413 x495 735 x 650 x 1765 590 x 600 x 870
Box size (l x w x h) mm 440 x 390 x 240 540 x 250 x 320 550 x 340 x 640
Net / gross weight kg 7,6/8,2 4,8/5,7 12/13
Units per box pcs 1 1 1
Units per pallet pcs 32 36 12

29
INFRARED ELECTRIC HEATERS ELECTRIC

FACT 20
IP20
2000 W
^ Not blinding lamps (GOLD)
^ No noise
^ Infrared heating
^ No air flow
^ Instant heat
^ No oxygen consumption
^ No fumes, no dust, no odors, no humidity
^ 100% efficiency
^ Short wave light
^ Life of the lamps: 5.000 hours

SPECIFICATIONS FACT 20
Heating power kW 2
Light spectrum IR-A
Infrared radiation short wave
Protection IP-20
Switch on/off no
Insulating class I
Power supply V 220-240
Frequency Hz 50-60
Lamp GOLD
Lamp life h 5000
Approximate area m2 12
Wall/ceiling support Included
Dimensions mm 235 x 496 x 313
Weight kg 1,7
Units per box pcs 1
Units per pallet pcs 32

30
INFRARED ELECTRIC HEATERS ELECTRIC

COFFEE 18
IP65
1800 W

^ Not blinding lamps (WHITE YELLOW - COFFEE 18,


RUBIN RED – CHAP 18)
^ No noise
^ Infrared heating
^ No air flow
^ Instant heat
^ No oxygen consumption
CHAP 18 ^ No fumes, no dust, no odors, no humidity
^ 100% efficiency
IP55 ^ Short wave light
1800 W ^ Life of the lamps: 5.000 hours

OPTIONAL ACCESSORIES:

Wall bracket
(COFFEE 18)
4165.786

SPECIFICATIONS COFFEE 18 CHAP 18


Heating power kW 1,8 1,8
Spectrum of light IR-A IR-A
Infrared radiation short wave short wave
Protection IP65 IP55
Switch on/off yes yes
Cable H05 H05
Power supply V 220-240 220-240
Frequency Hz 50-60 50-60
Lamp Quartz and tungsten wire Quartz and tungsten filament
Lamp life h 5000 5000
Approximate area m2 10 10
Dimensions mm 835 x 112 x 83 912 x 150 x 100
Weight kg 1 1,6
Units per box pcs 4 2
Units per pallet pcs 72 30

31
INFRARED ELECTRIC HEATERS ELECTRIC

SOMBRA 8
IP65
800 W
^ Not blinding lamps (RED)
^ No noise
^ Infrared heating
^ No air flow
^ Instant heat
^ No oxygen consumption
^ No fumes, no dust, no odors, no humidity
^ 100% efficiency
^ Short wave light
^ Life of the lamps: 5.000 hours

SPECIFICATIONS SOMBRA 8
Heating power kW 0,8
Spectrum of light IR-A
Infrared radiation short wave
Protection IP65
Switch and plug yes
Cable H05
Power supply V 220-240
Frequency Hz 50-60
Lamp Quartz and tungsten wire
Lamp life h 5000
Approximate area m2 4
Dimensions mm 400 x 132 x 90
Weight kg 0,9
Units per box pcs 2
Units per pallet pcs 64

32
DIRECT GAS FIRED AIR HEATERS
CF 75 SPARK
PROPANE NATURAL
BUTANE GAS

^ Designed for indoor and outdoor


^ Can be placed on the floor or hanged on the ceiling
^ Glavanized steel combustion chamber
^ Reliable twin spark ignition
^ Natural gas or LP gas burner
^ High efficiency heat exchanger
^ Overheat thermostat
^ Closed motor to assure safe, dependable even in harsh
CF 75 SPARK environments
^ Galvanized steel body

INCLUDED:

Diverter Kit to transform


LPG into NATURAL GAS

OPTIONAL ACCESSORIES:

Analog thermostat Digital thermostat THD Kit for oudoor


TH5 with cable with 5 m cable galvanized - 4230.102
3 m - 4150.109 4150.106
10 m - 4150.112 for heaters made
in Jul 2015 or later

Brackets
galvanized - 4230.120

SPECIFICATIONS CF 75 SPARK
kW 75
Heating power Btu/h 64.500
kcal/h 255.900
Air displacement m3/h 2.100
Thermostat control optional
Fuel consumption (LPG) m3/h 2,3
Fuel consumption (NATURAL GAS) m3/h 8,0
Power supply V 220-240
Frequency Hz 50
Electric power kW 0,5
Rated current A 2,8
Product size (l x w x h) mm 782 x 464 x 719
Box size (l x w x h) mm 825 x 515 x 780
Net/gross weight kg 57/61
Pallet pcs 4 Outdoor

33
INDIRECT OIL FIRED AIR HEATERS
STATIONARY DIESEL
OIL

^ Large built-in oil tank with filter


^ Integrated burner with electronic flame control
and photocell cut-off
^ Fan limit thermostat with automic reset
^ Summer-winter switch for ventilation only
BF 35 ^ Centrifugal fan
^ Stainless steel combustion chamber
BF 75 ^ Excellent heat insulation with detachable panels
^ Wide inspection doors for easy cleaning
^ Built in thermostat

SPECIFICATIONS BF 35 BF 75
kW 33,7 71,1
Heating power Btu/h 114.984 242.593
kcal/h 29.000 61.200
Air displacement m3/h 1.900 4.500
Fuel oil oil
Fuel consumption kg/h 2,84 6,00
Electric power kW 0,245 0,590
Power supply V 220-240 220-240
Frequency Hz 50 50
Flue tube Ø mm 120 150
Product size (l x w x h) mm 1050 x 460 x 1600 1220 x 540 x 1700
Box size (l x w x h) mm 1140 x 480 x 1730 1300 x 780 x 2130
Net weight kg 132 173

34
how to choose your heater
ΔT 30 ºC
SUGGESTED SUGGESTED HEATED
INFRARED HEATING AIRFLOW HEATING
HEATED AREA VOLUME

Oil Electric Electric Gas Direct Oil Indirect Oil

kW m2 kW m3 m3 m3 m3

1,5 HALL 2
– 4 B2 – – – 82 38 23 16
kW 1500 kW
2,4 3,3
– TS 3A 6 B3 – – – 135 63 38 27
kW kW
3,3 HALL 5
– 8 B5 – – – 205 96 57 41
kW 3000 kW
20 9
XL 61 – 16 B9 – – – 369 172 103 74
kW kW
43 10
XL 91 – 25 – – B 35 – 410 191 115 82
kW kW
15
B 15 – – – 614 287 172 123
kW
This chart will help you choosing the best heater
for your needs. The selection can be made in two 16
– BLP 17 – – 655 306 183 131
kW
ways: you can either refer to the power required
(kW column) and choose the relevant heaters or 18
B 18 – – – 737 344 206 147
kW
refer to the room dimension (m3 column) and
choose the correct heater according to level of 20
– – B 70 BV 77 819 382 229 164
kW
insulation.
22
B 22 – – – 901 420 252 180
kW
This calculation is intended for a temperature
increase of 30 degrees: for lower or higher increases, 29
– – B 100 – 1188 554 333 238
kW
the result will change in proportion. Example: for a
30
tempe­ra­ture increase of 10 degrees it is required kW
RS 30 – – – 1229 573 344 246
only 1/3 of the power indicated in the chart.
33 BV 110
– BLP 33 – 1351 631 378 270
kW BF 35
40
RS 40 – – – 2393 764 458 327
K=0,5  Well insulated buildings kW
(houses and offices) 44
– – B 150 – 1802 841 505 360
K=1,5  Moderately insulated buildings kW
(garages)
47
K=2,5 Poorly insulated buildings – – – BV 170 1925 898 539 385
kW
(old houses and cellars)
48
K=3,5  Not insulated buildings – – B 180 – 1966 917 550 393
kW
(wood or corrugated metal buildings,
greenhouses) 53
– BLP 53 – – 2170 1013 608 434
kW
65
– – B 230 – 2662 1242 745 532
For a finer calculation you can refer kW
to the following formula: 73
– BLP 73 – BF 75 2990 1395 837 598
kW
V x ΔT x K/860 = kW 75
– – – BV 310 3071 1433 860 614
kW
V is the volume to be heated in m 3
81
– – – BV 290 3317 1548 929 663
ΔT is the difference betwen the existing kW
and desired temperature in ºC 90
– – B 300 – 5160 1720 1032 737
K is the dispersion coefficient kW
(from 0,5 to 3,5) 103
– BLP 103 – – 4218 1968 1181 844
kW
111
– – B 360 – 4546 2121 1273 909
1 kW = 860 kcal/h kW
1 kcal/h = 3,97 Btu/h 134 BV 470
– – – 5488 2561 1537 1098
1 kW = 3412 Btu/h kW BV 500
1 Btu/h = 0,252 kcal/h 220
– – – BV 690 9010 4204 2523 1802
kW

35
How to choose your tube

FLEX TUBE

black and black and black and


white
yellow yellow yellow

adaptor flex tube flex tube flex tube flex tube flex tube
for flex tube diameter length length length length

HEATER mm inches 3.0 m 7.6 m 15 m 7.6 m


BV 77 1 WAY 4032.950 305 12 4515.550 4515.553 4515.588

1 WAY 4031.909 407 16 4031.401 4515.589


BV 110
2 WAYS 4033.230 305 12 4515.550 4515.553 4515.588

1 WAY 4031.909 407 16 4031.401 4515.589


BV 170
2 WAYS 4033.230 305 12 4515.550 4515.553 4515.588

1 WAY 4031.910 610 24 4031.038 4515.587


BV 290
2 WAYS 4033.229 407 16 4031.401 4515.589

1 WAY 4033.976 407 16 4031.401 4515.551 4515.589


BV 500
2 WAYS not required 305 12 4515.550 4515.553 4515.588

1 WAY not required 450 18 4515.554


BV 310 1 WAY
4 WAYS 4514.789 230 9 4515.557

1 WAY 4514.097 610 24 4031.038 4515.587

BV 470 4 WAYS 2 WAYS 4514.096 407 16 4031.401 4515.589

4 WAYS not required 305 12 4515.550 4515.553 4515.588

1 WAY 4514.093 710 28 4515.556

BV 690 4 WAYS 2 WAYS 4514.080 508 16 4515.552 4515.590

4 WAYS not required 330 12 4515.558

1 WAY not required 305 12 4515.550 4515.553 4515.588


B 18 EPR
2 WAYS 4511.808 230 9 4515.557

1 WAY not required 407 16 4031.401 4515.551 4515.589


B 30 EPR
2 WAYS 4511.807 305 12 4515.550 4515.553 4515.588

RS 30 1 WAY 4210.180 508 16 4515.552 4515.590

RS 40 1 WAY 4210.180 508 16 4515.552 4515.590

PERFORATED TUBE

adaptor perforated tube perforated tube tube hanger


for perforated tube diameter length for perforated tube

HEATER mm sold per meter


BV 310 1 WAY 1 WAY 4517.719 509 4514.593 4517.716

BV 470 1 WAY 1 WAY 4517.720 611 4514.594 4517.717

BV 690 1 WAY 1 WAY 4517.721 713 4517.617 4517.718

36
HEATING SOLUTIONS FOR:
AGRICULTURE, construction, events,
workshops & garages, industry & warehouses

AGRICULTURE

construction

events

workshops
& garages

industry
& WAREHOUSES

37
REMOTE CLIMATE CONTROL
INTELLIGENT MONITORING
With MASTER IMCS you follow from remote what the heaters and the dehumidifiers are doing.

IMCS is an innovative system for the remote control


of the climate in the room via GSM.

It allows:
MONITORING: RCC monitors the function of dehumidifiers
or heaters installed in a room

RECORDING: RCC records the level of humidity or


temperature in the room, giving a secure
documentation about the job done

REDUCING
COSTS: RCC reduces operating costs because there
is no need to visit the room and, once the
level of humidity or temperature is achieved,
the equipment can be stopped by remote With the computer or a tablet you can access to the cloud and read
or automatically. in a DASHBOARD the following information:

^ temperature
^ humidity
^ running time
^ energy consumption

HOW IMCS WORKS

THE CLOUD

IMS
[sensor of humdity
and temperature]

IMS
[sensor]
COMPUTER
LAPTOP
SMARTPHONE
IMS
[sensor] IMC
[GSMunit]

The IMS SENSORS measure the temperature and the humidity


in the room and send the information to the IMC, the GSM
COMMUNICATION UNIT.

The IMC sends the information to the Cloud.

38
REMOTE CLIMATE CONTROL
INTELLIGENT MONITORING

MASTER Remote Climate DASHBOARD

^ Administration of any number of damage cases


^ Geographical position available and route making
^ QR codes to scan IMC and get information
or scan more sensors
^ Alarm administration and Alarm receivers
^ Turn dehumidifiers and heaters on/off
^ All data in real time

IMC (GSMunit) IMS (sensor)

SPECIFICATION
IMR (On/Off Unit)
IMC (GSM unit)
Capacity Up to 32 sensors per system
Power 230 V
Product size (l x w x h) 17 cm x 16 cm x 9 cm
Transmitting GSM-signal present
IMS (sensor)
Power 3 pcs alkaline AAA
Transmitting wireless 433 mhz
Size sensor (l x w x h) 8.5 cm x 6.5 cm x 6.5 cm
Size probe (l x Ø) 4 cm x 1,4 cm
Accuracy probe +/- 1.8 %RH with long term stability
Temperature range probe - 40 ºC – + 90 ºC
Humidity range probe 0 - 100 %RH (not in water)

COMPONENTS

IMS: the wireless climate sensor IMS measures temperature and humidity in the room and speaks with the IMC unit.

IMC: this unit collects the data from several IMS units (up to 32 sensors) and sends them via GSM to the cloud.

IMR: this can be connected between the power plug and the heater or dehumidifier and allows to remote or automatically
turn on/off the heater or dehumidifier.

MASTER IMCS start package includes: 1 unit IMC and 3 units IMS.

39
WHY I CHOOSE MASTER DEHUMIDIFIERS?

SAVE TIME REDUCE


THE INVESTMENT COSTS
MASTER dehumidifiers speed
up many renovation and You can choose the capacity
construction works you need

CHOOSE USE THE SAME


THE BEST SOLUTION DEHUMIDIFIER
MASTER dehumidifiers’ offer is
IN DIFFERENT PLACES
adjusted to many different applications
such as industry, construction and also MASTER dehumidifiers are portable
office or house

STAY IN HEALTHY REDUCE


ENVIRONMENT OPERATING COSTS
MASTER dehumidifiers prevent MASTER dehumidifiers are
mould and bacteria development energy saving

PROTECT PROTECT YOUR


THE ENVIRONMENT PROPERTY
MASTER dehumidifiers MASTER dehumidifiers prevent damages
use eco-friendly refrigerant caused by moisture in buildings and keep
goods that are stored there dry

SAVE
MONEY
Dehumidification process is much more
efficient and cheaper than traditional
methods where you need to heat up
and ventilate the room

40
INDEX
CAPACITY: BEST FOR: PAGE

PROFESSIONAL Highly efficient machines designated to operate 27 - 80 Construction 44


CONDENSATION in harsh work conditions. The best for industry l/24h Industry
DEHUMIDIFIERS and construction. Warehouse
- construction Agriculture
Restoration works
Rental

PROFESSIONAL Mobile machines that are used in all types of 20 - 72 Restoration works 45-47
CONDENSATION rooms. Application of this type of condensation l/24h Public spaces
DEHUMIDIFIERS dehumidifiers will speed up a lot of finishing and House
- all purpose redecoration works. Agriculture
Rental

PROFESSIONAL Condensation dehumidifiers with a big air flow for 166 - 220 Construction 48-49
CONDENSATION fast and effective dehumidification. Supplied with l/24h Industry
DEHUMIDIFIERS a powerful and quiet centrifugal fan, big air filter Warehouse
- industrial and three phase compressor secured by phase Agriculture
protection. The best for industry. Meat processing
Food processing

CONDENSATION They remove humidity from rooms, prevent mould 10 - 45 Agriculture 50-51
DEHUMIDIFIERS and bacteria development. An active filter prevents l/24h Restoration works
- house unpleasant odours. Air dehumidifiers are widely Public spaces
- workplace used in apartments, garages, cellars, libraries, House
- hotels drying rooms, bathrooms, and others. Hotels
Ski resorts

ADSORPTIVE DESICCANT A dehumidifier which operates without refrigerant. 18,75 - 25,7 Industry 52
DEHUMIDIFIERS It has almost consistent rate of water extraction at l/24h Agriculture
INDUSTRIAL all temperatures and is more efficient than compres- Restoration works
sor based dehumidifiers when used at low tempera- Public spaces
tures below down to -10ºC.

CHART How to choose your dehumidfier. 53

Remote Climate The innovative system for the remote control of 38-39
Control the climate using GSM. It monitors the function
of heaters or dehumidifiers installed in a room.

41
SOLUTIONS FOR:
CONSTRUCTION, PRODUCTION AND LOGISTICS, AGRICULTURE

HOUSE
All ADSORPTIVE
CONSTRUCTION INDUSTRIAL WORKPLACE
APPLICATION purpose
HOTELS
DESICCANT

CONSTRUCTION

MOISTURE
REMOVAL
IN NEW HOUSES

DRYING DURING
CONSTRUCTION

WATER
REMOVAL
AFTER PAINTING

PRODUCTION & LOGISTIC

PREVENTING
MOULD GROWTH
IN WAREHOUSES

KEEPING
HUMIDITY LEVEL
DURING
TECHNOLOGICAL
PROCESSES

PREVENTING
CONDENSATION
AND CORROSION

AGRICULTURE

DRYING
LIVESTOCK
FACILITIES
AFTER CLEANING

STORAGE
FACILITIES
DESICCATION

DRYING MEAT

42
SOLUTIONS FOR:
RESTORATION WORKS, PUBLIC SPACES, HOUSES

HOUSE
All ADSORPTIVE
CONSTRUCTION INDUSTRIAL WORKPLACE
APPLICATION purpose
HOTELS
DESICCANT

RESTORATION WORKS

WATER
DAMAGE
RESTORATION

DRYING
FLOODED
PREMISES

DRYING AFTER
FIRE FIGHTING
INTERVENTION

PUBLIC SPACES

DRYING SHOPS,
OFFICES

DECREASE
HUMIDITY
IN CLOAKROOMS,
SKI RESORTS

KEEPING
HUMIDITY LEVEL
IN LIBRARIES,
MUSEUMS, ARCHIVE

PROTECTING
ELECTRONIC
EQUIPMENT
FROM HUMIDITY

HOUSES

DRYING
GARAGES,
CELLARS

DRYING
IN LAUNDRIES

43
PROFESSIONAL CONDENSATION DEHUMIDIFIERS
construction

^^ Long lasting steel casing


DH 26 ^^ High efficiency
^^ Hour counter
^^ Large water tank with automatic shut-off when full
^^ Possibility of continuous operation (24 h/day)
^^ Possibility to connect a hose to remove condensed water
^^ Tank full indicator
^^ Air filter
^^ Automatic fast defrosting by hot gases
^^ Restarts automatically after a power failure
^^ Large wheels and handle
^^ Built-in hygrostat

DH 44
DH 62 Wide spaces between Compact foam air filter Manual control
DH 92 evaporator tubes enables work in very resistant to hard
prevent clogging. dusty spaces. condition.

SPECIFICATIONS DH 26 DH 44 DH 62 DH 92
Capacity (30°C/80% RH) l/24h 27 41 52 80
Capacity (20°C/60% RH) l/24h 12 17 20 32
For rooms of approx. m3 405 615 780 1200
For restoration after flood m3 162 246 312 480
Air displacement m3/h 350 480 480 1000
Operating range:
temperature °C 0,5-35 3-35 3-35 3-35
humidity % 35-99 35-99 35-99 35-99
Refrigerant R410A R410A R410A R410A
Power consumption W 620 780 990 1.600
Power supply v 220-240 220-240 220-240 220-240
Frequency Hz 50 50 50 50
Noise dB(A) 46 53 53 50
Compressor rotary rotary rotary rotary
Tank capacity l 8 11 11 11
Product size (l x w x h) mm 450 x 470 x 890 600 x 580 x 850 600 x 580 x 850 580 x 600 x 1035
Box size (l x w x h) mm 430 x 400 x 730 590 x 580 x 830 590 x 580 x 850 590 x 580 x 1020
Net/gross weight kg 30/33 43/47 47/51 66/70
Pallet pcs 8 4 4 2
Dual voltage no available available no

44
PROFESSIONAL CONDENSATION DEHUMIDIFIERS
ALL PURPOSE, RENTAL

^ Easy to open for cleaning


^ Can be cleaned with water jet
^ Stackable
^ Possibility to have, at the same time, on board water pump
and on board water tank
PATENTED
DHP 65 ^ On board humidistat
^ Room humidistat socket
^ Heavy duty, rotomoulded casing
^ High efficiency
^ Hour counter
^ Large water tank with automatic shut-off when full
^ Possibility of continuous operation (24 h/day)
^ Possibility to connect a hose to remove condensed water
^ Tank full indicator
^ Air filter
^ Automatic fast defrosting by hot gases
^ Restarts automatically after a power failure
^ Large wheels and handle
Hour counter On board humidity control

OPTIONAL ACCESSORIES:

Water pump
Max. forcing height - 4m
4140.029

SPECIFICATIONS DHP 65
Capacity (30°C/80% RH) l/24h 56
Capacity (20°C/60% RH) l/24h 22
For rooms of approx. m3 840
For restoration after flood m3 336 Heavy duty, rotomoulded casing
Air displacement m3/h 500
Operating range:
temperature °C 3-35
humidity % 38-99
Refrigerant R410A
Power consumption W 780
Power supply V 220-240
Frequency Hz 50
Noise dB(A) 53
Compressor rotary
Tank capacity l 10,5
Product size (l x w x h) mm 570 x 530 x 700
Box size (l x w x h) mm 730 x 580 x 840
Net/gross weight kg 45/50 Easy to open for cleaning Stackable
Pallet pcs 4
Dual voltage available

45
PROFESSIONAL CONDENSATION DEHUMIDIFIERS
ALL PURPOSE, COMPACT

DH 732
^^ High efficiency
^^ Durable casing
^^ Simple operation
^^ Built-in hygrostat
^^ Possibility of continous operation (24 h/day)
^^ Water tank with automatic shut-off when full
^^ Possibility to connect a hose to remove condensed water
^^ Air filter
^^ DH 732 are stackable

DH 721

Light and compact casing

SPECIFICATIONS DH 721 DH 732


Capacity (30°C/80% RH) l/24h 20 30
Capacity (20°C/60% RH) l/24h 7 10,8
For rooms of approx. m3 390 450
For restoration after flood m3 156 180
Air displacement m3/h 240 160
Operating range:
temperature °C 5-35 5-32
humidity % 35-90 35-90
Refrigerant R134a R410A
Power consumption W 490 680
Power supply v 220-240 220-240
Frequency Hz 50 50
Noise dB(A) 42 42
Compressor piston rotary
Tank capacity l 4,7 6,5
Product size (l x w x h) mm 335 x 305 x 580 358 x 338 x 550
Box size (l x w x h) mm 380 x 350 x 640 402 x 387 x 592
Net/gross weight kg 19/21 19,5/21
Pallet pcs 18 18

46
PROFESSIONAL CONDENSATION DEHUMIDIFIERS
ALL PURPOSE

DH 752 ^^ Automatic fast defrosting by hot gases


^^ High efficiency
^^ Durable casing
^^ Simple operation
^^ Built-in hygrostat
^^ Possibility of continuous operation (24 h/day)
^^ Water tank with automatic shut-off when full
^^ Possibility to connect a hose to remove condensed water
^^ Hour counter
^^ Air filter

DH 772

OPTIONAL ACCESSORIES:

Water pump for DH 752 and DH 772


Max. forcing height - 4m
4512.409

SPECIFICATIONS DH 752 DH 772


Capacity (30°C/80% RH) l/24h 47,2 72
Capacity (20°C/60% RH) l/24h 20,3 49
For rooms of approx. m3 701 1080
For restoration after flood m3 280 432
Air displacement m3/h 350 850
Operating range:
temperature °C 5-35 5-32
humidity % 20-90 35-90
Refrigerant R410A R407C
Power consumption W 900 1790
Power supply v 220-240 220-240
Frequency Hz 50 50
Noise dB(A) 52 60
Compressor rotary rotary
Tank capacity l 5,7 15
Product size (l x w x h) mm 580 x 422 x 820 586 x 436 x 1110
Box size (l x w x h) mm 610 x 405 x 660 730 x 530 x 1170
Net/gross weight kg 30/36 59/64
Pallet pcs 12 2

47