Sei sulla pagina 1di 6

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/235987484

High performance liquid chromatography: A short review

Article  in  Journal of Global Pharma Technology · June 2010

CITATIONS READS

9 59,636

4 authors, including:

Rishabha Malviya
Galgotias University
102 PUBLICATIONS   781 CITATIONS   

SEE PROFILE

Some of the authors of this publication are also working on these related projects:

Polymer Modification and Applications View project

extraction of okra mucilage View project

All content following this page was uploaded by Rishabha Malviya on 29 May 2014.

The user has requested enhancement of the downloaded file.


ISSN 0975 – 8542
Journal of Global Pharma Technology
Available Online at www.jgpt.co.in
REVIEW ARTICLE

HIGH PERFORMANCE LIQUID CHROMATOGRAPHY: A SHORT


REVIEW

Malviya R, Bansal V*, Pal O.P. and Sharma P.K.

Department of pharmaceutical technology, Meerut Institute of Engineering and Technology,


Meerut, India
*For correspondence: Email: vipinbansal1986@gmail.com

Abstract: High performance liquid chromatography (HPLC) is an important qualitative and quantitative
technique, generally used for the estimation of pharmaceutical and biological samples. It is the most
versatile, safest, dependable and fastest chromatographic technique for the quality control of drug
components. This article was prepared with an aim to review different aspects of HPLC, such as principle,
types, instrumentation and application.

Keywords: High performance liquid chromatography, instrumentation, elution, applications, mobile phase.

INTRODUCTION miscible combinations of water or organic


liquids (the most common are methanol
High-performance liquid chromatography and acetonitrile). [2, 3] Sepration has been
(or High pressure liquid chromatography, done to vary the mobile phase composition
HPLC) is a specific form of column during the analysis; this is known as
chromatography generally used in gradient elution. [3] The gradient separates
biochemistry and analysis to separate, the analyte mixtures as a function of the
identify, and quantify the active affinity of the analyte for the current
compounds. [1] HPLC mainly utilizes a mobile phase. The choice of solvents,
column that holds packing material additives and gradient depend on the
(stationary phase), a pump that moves the nature of the stationary phase and the
mobile phase(s) through the column, and a analyte.
detector that shows the retention times of
the molecules. Retention time varies TYPES OF HPLC
depending on the interactions between the
stationary phase, the molecules being Types of HPLC generally depend on phase
analyzed, and the solvent(s) used. [2] The system used in the process. [3, 4]
sample to be analyzed is introduced in Following types of HPLC generally used
small volume to the stream of mobile in analysis-
phase and is retarded by specific chemical
or physical interactions with the stationary Normal phase chromatography: Also
phase. The amount of retardation depends known Normal phase HPLC (NP-HPLC),
on the nature of the analyte and this method separates analytes based on
composition of both stationary and mobile polarity. NP-HPLC uses a polar stationary
phase. The time at which a specific analyte phase and a non-polar mobile phase. The
elutes (comes out of the end of the polar analyte interacted with and is
column) is called the retention time. retained by the polar stationary phase.
Common solvents used include any Adsorption strengths increase with
© 2009, JGPT. All Rights Reserved. 22
Bansal V. et al., Journal of Global Pharma Technology. 2010; 2(5): 22-26

increased analyte polarity, and the Proteins bound to a bioaffinity column can
interaction between the polar analyte and be eluted in two ways:
the polar stationary phase increases the • Biospecific elution: inclusion of free
elution time. ligand in elution buffer which
competes with column bound ligand.
Reversed phase chromatography: • Aspecific elution: change in pH, salt,
Reversed phase HPLC (RP-HPLC or RPC) etc. which weakens interaction protein
has a non-polar stationary phase and an with column-bound substrate.
aqueous, moderately polar mobile phase. Because of specificity of the interaction,
RPC operates on the principle of bioaffinity chromatography can result in
hydrophobic interactions, which result very high purification in a single step (10 -
from repulsive forces between a polar 1000-fold).
eluent, the relatively non-polar analyte,
and the non-polar stationary phase. The PARAMETERS
binding of the analyte to the stationary
phase is proportional to the contact surface For the accurate analysis of a compound,
area around the non-polar segment of the there are some parameters which are used
analyte molecule upon association with the as a standard for a particular compound. If
ligand in the aqueous eluent. there is a change occurs in the parameters
the result may be affected greatly. The
Size exclusion chromatography: Size most commonly used parameters are
exclusion chromatography (SEC), also internal diameter, particle size, pore size,
called as gel permeation chromatography pump pressure. For different compounds
or gel filtration chromatography mainly the parameters can be changed according
separates particles on the basis of size. It is to their nature and chemical properties.
also useful for determining the tertiary
structure and quaternary structure of Internal diameter: The internal diameter
proteins and amino acids. This technique is (ID) of an HPLC column is a critical
widely used for the molecular weight aspect that determines quantity of analyte
determination of polysaccharides. that can be loaded onto the column and
also influences sensitivity. Larger columns
Ion exchange chromatography: In Ion- are usually seen in industrial applications
exchange chromatography, retention is such as the purification of a drug product
based on the attraction between solute ions for later use. Low ID columns have
and charged sites bound to the stationary improved sensitivity and lower solvent
phase. Ions of the same charge are consumption at the expense of loading
excluded. This form of chromatography is capacity.
widely used in purifying water, Ligand-
exchange chromatography, Ion-exchange Particle size: Most traditional HPLC is
chromatography of proteins, High-pH performed with the stationary phase
anion-exchange chromatography of attached to the outside of small spherical
carbohydrates and oligosaccharides, etc. silica particles (very small beads). Smaller
[3, 4] particles generally provide more surface
area and better separations, but the
Bio-affinity chromatography: Separation pressure required for optimum linear
based on specific reversible interaction of velocity increases by the inverse of the
proteins with ligands. Ligands are particle diameter squared.
covalently attached to solid support on a
bio-affinity matrix, retains proteins with Pore size: Many stationary phases are
interaction to the column-bound ligands. porous to provide greater surface area.

© 2009, JGPT. All Rights Reserved. 23


Bansal V. et al., Journal of Global Pharma Technology. 2010; 2(5): 22-26

Small pores provide greater surface area calculated automatically by the computer
while larger pore size has better kinetics linked to the display.
especially for larger analytes. Pore size
defines an ability of the analyte molecules APPLICATION
to penetrate inside the particle and interact
with its inner surface. This is especially The information that can be obtained using
important because the ratio of the outer HPLC includes identification,
particle surface to its inner one is about quantification, and resolution of a
1:1000. The surface molecular interaction compound. Preparative HPLC refers to the
mainly occurs on the inner particle surface. process of isolation and purification of
compounds. This differs from analytical
Pump pressure: Pumps vary in pressure HPLC, where the focus is to obtain
capacity, but their performance is information about the sample compound.
measured on their ability to yield a
consistent and reproducible flow rate. Chemical Separations It is based on the
Modern HPLC systems have been fact that certain compounds have different
improved to work at much higher migration rates given a particular column
pressures, and therefore be able to use and mobile phase, the extent or degree of
much smaller particle sizes in the columns separation is mostly determined by the
(< 2 micrometres). choice of stationary phase and mobile
phase.
INSTRUMENTATION
Purification: Purification is defined as the
Injection of the sample: Septum injectors process of separating or extracting the
are available; using which sample solution target compound from a mixture of
is injected. Sample can be injected when compounds or contaminants. Each
the mobile phase is flowing or it is compound showed a characteristic peak
stopped. A new advanced rotary valve and under certain chromatographic conditions.
loop injector can be used to produce The migration of the compounds and
reproducible results. contaminants through the column need to
differ enough so that the pure desired
The detector: There are several ways of compound can be collected or extracted
detecting when a substance has passed without incurring any other undesired
through the column. Generally UV compound.
spectroscopy is attached, which detect the
specific compounds. Many organic Identification Generally assay of
compounds absorb UV light of various compounds are carried using HPLC. The
wavelengths. The amount of light parameters of this assay should be such
absorbed will depend on the amount of a that a clean peak of the known sample is
particular compound that is passing observed from the chromatograph. The
through the beam at the time. identifying peak should have a reasonable
retention time and should be well
Interpreting the output from the separated from extraneous peaks at the
detector: The output is recorded as a detection levels which the assay will be
series of peaks, each one representing a performed.
compound in the mixture passing through
the detector and absorbing UV light. The Other applications of HPLC: Other
area under the peak is proportional to the applications of HPLC includes
amount of substance, which is passed
through detector, and this area can be

© 2009, JGPT. All Rights Reserved. 24


Bansal V. et al., Journal of Global Pharma Technology. 2010; 2(5): 22-26

Pharmaceutical applications [5-8] CONCLUSION


• Tablet dissolution study of
armaceutical dosages form. It can be concluded from the entire review
• Shelf-life determinations of that HPLC is a versatile, reproducible
parmaceutical products chromatographic technique for the
• Identification of active ingredients of estimation of drug products. It has wide
dosage forms applications in different fields in term of
• Pharmaceutical quality control quantitative and qualitative estimation of
active molecules.
Environmental applications [9-12]
• Detection of phenolic compounds in REFERENCES
Drinking Water
1. Martin M., Guiochon, G. Effects of
• Identification of diphenhydramine in high pressures in liquid
sedimented samples chromatography. J. Chromatogr. A,
• Bio-monitoring of pollutant 2005; (1-2)7: 16-38.

Forensics [13-15] 2. Liu Y., Lee M.L. Ultrahigh pressure


• Quantification of the drug in biological liquid chromatography using elevated
temperature. Journal of
samples. Chromatography. 2006; 1104 (1-2):
• Identification of anabolic steroids in 198–202.
serum, urine, sweat, and hair
• Forensic analysis of textile dyes. 3. Abidi,S.L. High-performance liquid
• Determination of cocaine and chromatography of phosphatidic acids
and related polar lipids. J. Chromatogr.
metabolites in blood 1991; 587: 193-203.
Clinical [16-19] 4. Hearn M.T.W. Ion-pair
• Quantification of ions in human urine chromatography on normal and
Analysis of antibiotics in blood reversed-phase systems. Adv.
plasma. Chromatogr. 1980; 18: 59–100.
• Estimation of bilirubin and bilivirdin in 5. Bergh J. J., Breytenbach, J. C.
blood plasma in case of hepatic Stability-indicating High-performance
disorders. Liquid- chromatographic Analysis of
• Detection of endogenous Trimethoprim in Pharmaceuticals. J.
neuropeptides in extracellular fluids of Chromatogr. 1987; 387: 528-531.
brain.
6. Stubbs C., Kanfer, I. Stability-indi-
cating High-performance Liquid-
FoodandFlavor [20] chromato- graphic Assay of
• Ensuring the quality of soft drink and Erythromycin Estolate in
drinking water. Pharmaceutical Dosage Forms. Int. J.
• Analysis of beer. Pharm. 1990; 3(2): 113-119.
• Sugar analysis in fruit juices. 7. MacNeil L., Rice J. J., Muhammad N.
• Analysis of polycyclic compounds in Lauback R. G. Stability-indicating
vegetables. Liquid-chromatographic Determination
• Trace analysis of military high of Cefapirin, Desacetylcefapirin and
explosives in agricultural crops. Cefapirin Lactone in Sodium Cefapirin
Bulk and Injectable Formulations. J.
Chromatogr. 1986; 361: 285-290.

8. Bounine J. P., Tardif B., Beltran P.


Mazzo D. J. High-performance Liquid-

© 2009, JGPT. All Rights Reserved. 25


Bansal V. et al., Journal of Global Pharma Technology. 2010; 2(5): 22-26

chromatographic Stability-indicating tissue. Antimicrob. Agents Chemother.


Determination of Zopiclone in Tablets. 1986; 30: 31-233.
J. Chromatogr. 1994; 677(1): 87-93.
15. Haginaka J., Yasuda H., Uno T.,
9. Lauback R. G., Rice J. J., Bleiberg B., Nkagawa T. Alkaline degradation and
Muhammad N., Hanna, S. A. 1984. determination by high-performance by
Specific High-performance Liquid- high-performance liquid
chromato- graphic Determination of chromatography. Chem. Pharm. Bull.
Ampicillin in Bulks, Injectables, 1984; 32: 2752-2758
Capsules and Oral Suspensions by
Reversed-phase Ion-pair 16. Fredj G., Paillet Aussel M. F., Brouard
Chromatography. J. Liq. Chromatogr. A., Barreteau H., Divine C., Micaud
1984; 7(6): 1243-1265. M. Determination of sulbactam in
biological fluids by high-performance
10. Wiklund A E., Dag B., Brita S. liquid chromatography. J. Chromatogr.
Toxicity evaluation by using intact 1986; 383: 218-222.
sediments and sediment extracts.
Marine Pollution Bulletin (2005); 17. Rodenas V., Garcia M.S., Sanchez-
50(6): 660-667. Pedreno C., Albero M.I. Flow-
injection spectrophotometric
11. Kwok Y. C., Hsieh D. P. H., Wong P. determination of frusemide or
K. Toxicity identification evaluation sulphathiazole in pharmaceuticals. J.
(TIE) of pore water of contaminated Pharm. Biomed. Anal. 1997; 15: 1687-
marine sediments collected from Hong 1693.
Kong waters. Marine Pollution
Bulletin. 2005; 51(8-12): 1085-1091. 18. Shah A.J., Adlard M.W., Stride J.D. A
sensitive assay for clavulanic acid and
12. Hongxia Yu., Jing C., Cui Y., Shang sulbactam in biological fluids by high-
H., Ding Z., Jin H. Application of performance liquid chromatography
toxicity identification evaluation and precolumn derivatization. J.
procedures on wastewaters and sludge Pharm. Biomed. Anal. 1990; 5: 437-
from a municipal sewage treatment 443.
works with industrial inputs.
Ecotoxicology and Environmental 19. Abidi S.L. High-performance liquid
Safety. 2004; 57(3): 426-430. chromatography of phosphatidic acids
and related polar lipids. J.Chromatogr.
13. Ayerton J. Assay of ceftazidime in 1991; 587: 193-203.
biological fluids using high-pressure
liquid chromatography. J. Antimicrob. 20. Christie W.W., Gill S., Nordbäck J.,
Chemother. 1981; 8: 227-231. Itabashi Y., Sanda S., Slabas A.R. New
procedures for rapid screening of leaf
14. Bowden R.E., Madsen P.O. High- lipid components from Arabidopsis.
pressure liquid chromatographic assay Phytochemical Anal. 1998; 9: 53-57.
of sulbactam in plasma, urine and

© 2009, JGPT. All Rights Reserved. 26

View publication stats

Potrebbero piacerti anche