Sei sulla pagina 1di 8

MIDAS Information Technology Co.

, Ltd 

■ MEMBER NAME : 1C1(33) 

1. General Information 

(1) Design Code   : Eurocode2:04 

(2) Unit System   : N, mm 

(3) γc : 1.500 

(4) γs : 1.150 

(5) αcc : 0.850 

2. Material 

(1) fck  : 25.00MPa 

(2) fyk  : 400MPa 

3. Section 

(1) Foundation 

ㆍ Depth  : 1,100mm 

ㆍ Cover  : 50.00mm 

(2) Column Section 

ㆍ Shape of Column   : Rectangle 

ㆍ Section  : 600x600mm 

4. Rebar 

(1) Direction Y 

ㆍ Layer 1  : P20@200 (As = 1,571mm²) 

(2) Direction X 

ㆍ Layer 1  : P20@200 (As = 1,571mm²) 

http://www.midasuser.com     

1/8 
MIDAS Information Technology Co., Ltd 

5. Foundation 

(1) Foundation Size 

ㆍ Lx  : 4.000m 

ㆍ Ly  : 4.000m 

ㆍ fe  : 300KPa 

6. Design Forces 

(1) Service Load ( by Load Combinations ) 

NEd,s   MEd,sx  MEd,sy 


No  CHK  Name  Description 
(kN)  (kN∙m)  (kN∙m) 

‐  ‐  cLCB18  3,930  9.746  ‐38.73  SERV :1.0D + 1.0LL ‐ 0.6WY 

1  Yes  cLCB18  3,930  9.746  ‐38.73  SERV :1.0D + 1.0LL ‐ 0.6WY 

2  Yes  cLCB26  3,299  5.507  ‐48.08  SERV :1.0D + 1.0LL + 0.2WY 

3  Yes  cLCB19  3,647  21.18  ‐48.55  SERV :1.0D + 1.0LL + 1.0WX 

4  Yes  cLCB21  3,661  ‐7.249  ‐49.39  SERV :1.0D + 1.0LL ‐ 1.0WX 

5  Yes  cLCB22  3,677  10.72  ‐24.71  SERV :1.0D + 1.0LL ‐ 1.0WY 

6  Yes  cLCB20  3,631  3.212  ‐73.23  SERV :1.0D + 1.0LL + 1.0WY 

(2) Ultimate Load ( by Load Combinations ) 

NEd,u   MEd,ux  MEd,uy 


No  CHK  Name  Description 
(kN)  (kN∙m)  (kN∙m) 

‐  ‐  cLCB7  5,591  14.05  ‐54.20  1.4D + 1.5(1.0LL) ‐ 1.5(0.6)WY 

1  Yes  cLCB7  5,591  14.05  ‐54.20  1.4D + 1.5(1.0LL) ‐ 1.5(0.6)WY 

2  Yes  cLCB11  3,218  1.211  ‐98.28  1.0D + 1.0(0.3)L + 1.0EY 

3  Yes  cLCB10  3,268  70.71  ‐29.78  1.0D + 1.0(0.3)L + 1.0EX 

4  Yes  cLCB12  3,340  ‐58.20  ‐56.67  1.0D + 1.0(0.3)L ‐ 1.0EX 

5  Yes  cLCB13  3,390  11.30  11.82  1.0D + 1.0(0.3)L ‐ 1.0EY 

6  Yes  cLCB5  5,143  4.245  ‐106  1.4D + 1.5(0.7LL) + 1.5WY 

http://www.midasuser.com     

2/8 
MIDAS Information Technology Co., Ltd 

(3) Surcharge Load & Self Weight 

Self Weight  Surface Load  Weight Density  Soil Height 

Considered  ‐  ‐  ‐ 

4,000
2,000 2,000

y
2,000
4,000

Y1
2,000

X1
1,100

7. Check Soil Capacity 

(1) Calculate service soil stress (KPa) 

ㆍ qs,top‐left =276   qs,top‐right =269  

ㆍ qs,bot‐left =274   qs,bot‐right =267 

ㆍ qs,max =276   fe =300 

ㆍ qs,max / fe =0.920   →  O.K 

http://www.midasuser.com     

3/8 
MIDAS Information Technology Co., Ltd 

(2) Calculate ultimate soil stress (KPa) 

ㆍ qu,top‐left =391   qu,top‐right =381  

ㆍ qu,bot‐left =388   qu,bot‐right =378 

ㆍ qu,max =391   qu,min =378 

8. Calculate Moment Effective Depth 

(1) Direction X = 1,040mm (for MEdy) 

(2) Direction Y = 1,020mm (for MEdx) 

9. Check Moment Capacity ( Direction X ) 

(1) Calculate required area of reinforcement 

ㆍ K = MEd / ( bd2 fck) = 0.0189 

ㆍ K' = 0.598δ ‐ 0.18δ2 ‐ 0.21 = 0.208 

ㆍ z = min[ d(0.5+0.5  1‐3.53K ), 0.95d ] = 988mm 

ㆍ (Reference of 0.95d is 'The Concise Eurocode' 2006) 

 MEd 
ㆍ As,req =  f  z  = 1,485mm² 
yd

(2) Calculate limit of reinforcement area 

ㆍ fctm = 0.3 fck 2/3 = 2.565MPa 

 0.26 fctm bd 
ㆍ As min = max[   , 0.0013bd ] = 1,701mm² 
 fyk 

ㆍ As max = 0.04 Ac = 44,000mm² 

(3) Check area of tensile reinforcement 

ㆍ As > As,req  →  O.K 

ㆍ As < As,min  →  N.G 

(4) Calculate moment capacity at the column face 

ㆍ MEdy =510kN∙m   MRdy =540kN∙m 

ㆍ MEdy / MRdy =0.945   →  O.K 

http://www.midasuser.com     

4/8 
MIDAS Information Technology Co., Ltd 

10. Check Moment Capacity ( Direction Y ) 

(1) Calculate required area of reinforcement 

ㆍ K = MEd / ( bd2 fck) = 0.0195 

ㆍ K' = 0.598δ ‐ 0.18δ2 ‐ 0.21 = 0.208 

ㆍ z = min[ d(0.5+0.5  1‐3.53K ), 0.95d ] = 969mm 

ㆍ (Reference of 0.95d is 'The Concise Eurocode' 2006) 

 MEd 
ㆍ As,req =  f  z  = 1,502mm² 
yd

(2) Calculate limit of reinforcement area 

ㆍ fctm = 0.3 fck 2/3 = 2.565MPa 

 0.26 fctm bd 
ㆍ As min = max[   , 0.0013bd ] = 1,734mm² 
 fyk 

ㆍ As max = 0.04 Ac = 44,000mm² 

(3) Check area of tensile reinforcement 

ㆍ As > As,req  →  O.K 

ㆍ As < As,min  →  N.G 

(4) Calculate moment capacity at the column face 

ㆍ MEdx =506kN∙m   MRdx =529kN∙m 

ㆍ MEdx / MRdx =0.956   →  O.K 

11. Calculate Shear Effective Depth 

(1) Direction X = 1,040mm (for VEdx) 

(2) Direction Y = 1,020mm (for VEdy) 

http://www.midasuser.com     

5/8 
MIDAS Information Technology Co., Ltd 

12. Calculate one‐way shear (Direction X) 

(1) Calculate ratio of shear capacity 

ㆍ k = min [ 1 +  200/d , 2.0] = 1.439 

ㆍ ρl = min[ Asl / bw d, 0.02 ] = 0.00151 

ㆍ CRd,c = 0.18 / γc = 0.120 

ㆍ VRdx1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 1,118kN 

ㆍ VRdx2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 1,256kN 

ㆍ VRdx = max[ VRdx1 , VRdx2 ] = 1,256kN 

ㆍ VEdx = 956kN 

ㆍ VEdx / VRdx =0.761   →  O.K 

13. Check One‐Way Shear ( Direction Y ) 

(1) Calculate ratio of shear capacity 

ㆍ k = min [ 1 +  200/d , 2.0] = 1.443 

ㆍ ρl = min[ Asl / bw d, 0.02 ] = 0.00154 

ㆍ CRd,c = 0.18 / γc = 0.120 

ㆍ VRdy1 = [CRd,c k (100 ρl fck ) 1/3 + k1 σcp ] bw d = 1,107kN 

ㆍ VRdy2 = [0.035 k3/2 fck 1/2 + k1 σcp ] bw d = 1,237kN 

ㆍ VRdy = max[ VRdy1 , VRdy2 ] = 1,237kN 

ㆍ VEdy = 979kN 

ㆍ VEdy / VRdy =0.791   →  O.K 

http://www.midasuser.com     

6/8 
MIDAS Information Technology Co., Ltd 

14. Check Two‐Way Shear 

(1) Calculate Shear at Face of Column 

ㆍ U = 2,400mm 

ㆍ a = (ex / by) 2 

ㆍ b = (ey / bx) 2 

ㆍ β = 1+1.8   a+b  = 1.027 

 β NEd 
ㆍ νEd =   U d    = 2.556MPa 

ㆍ fcd = αcc fck / γc  = 14.17MPa 

ㆍ νRd,max = 0.5ν fcd = 3.825MPa 

ㆍ νEd / νRdMax =0.668   →  O.K 

(2) Calculate Shear at Distance‐2d 

ㆍ U = 0.000mm 

ㆍ β = 1+1.8   a+b  = 1.448 

ㆍ νEd = β VEd,red / Ud = 0.000MPa 

ㆍ k = min [ 1 +  200/d, 2.0] = 1.441 

ㆍ ρl = min[  ρly ρlz  , 0.02 ] = 0.00153 

ㆍ νRd,1 = CRd,c k (100 ρl fck) 1/3 + k1 σcp = 0.270 MPa 

ㆍ νRd,2 = 0.035 k3/2 fck 1/2 + k1 σcp = 0.303 MPa 

ㆍ νRd = max[ νRd,1 , νRd,2 ] = 0.303 MPa 

ㆍ νEd / νRd =0.000   →  O.K 

(3) Calculate Shear at Distance‐d 

ㆍ U = 8,872mm 

ㆍ β = 1.010 

ㆍ νEd = β VEd,red / Ud  = 0.418MPa 

ㆍ νRd,1 = CRd,c k (100 ρl fck) 1/3 x (2d/a) = 0.540 MPa 

ㆍ νRd,2 = 0.035 k3/2 fck 1/2 x (2d/a) = 0.605 MPa 

ㆍ νRd = max[ νRd,1 , νRd,2 ] = 0.605 MPa 

ㆍ νEd / νRd =0.690   →  O.K 

http://www.midasuser.com     

7/8 
MIDAS Information Technology Co., Ltd 

15. Check Rebar 

(1) X Direction 

ㆍ As,min =1,701mm²   As,max =44,000mm² 

ㆍ As = 1,571 (P20@200) > As,req = 1,485mm²   →  O.K 

ㆍ sx = 200mm < sMax. = 400mm   →  O.K  

(2) Y Direction 

ㆍ As,min =1,734mm²   As,max =44,000mm² 

ㆍ As = 1,571 (P20@200) > As,req = 1,502mm²   →  O.K 

ㆍ sy = 200mm < sMax. = 400mm   →  O.K  

http://www.midasuser.com     