1) UNIFORM GRAVITY LOADS (psf): _______________
OVER 10'-0" TO 14'-0" 1 HSS5X3X3/16 600S162-54
S101 E
LOCATION DEAD LOAD
OVERHEAD DOORS SEE FRAMING PLANS
FOLDING PARTITION WALL: 12 psf
* USE TABLE UNLESS NOTED OTHERWISE
C. MATERIALS ** 2- CONT STUDS MINIMUM AT ALL DOOR OPENINGS.
5
1) STRUCTURAL STEEL: _______________
W SHAPES ASTM A992, Fy = 50 ksi S101
VERIFY IN FIELD
S101 FIELD VERIFY BEAM DOES NOT @16" (TYP)
3) PRIMARY STEEL SHAPES INDICATED ON THE DRAWINGS ARE DESIGNATED PER THE STEEL STUD
MANUFACTURERS ASSOCIATION (SSMA) TERMINOLOGY. INTERFERE WITH EXISTING DUCTS WHERE SHOWN
OPTIONAL
30' - 0"
PRIOR TO STEEL DETAILING
(914)
EXAMPLE OF TERMINOLOGY: 600S162-54 (50)
W12X50
VS SCREWS MATCH STUD T200-54
600 = DEPTH X 1/100 INCHES I.E. 6"
S = SHAPE I.E. C-STUD OR JOIST SHAPE WITH FLANGE EDGE RETURNS W/O SPLICES TOP & BOT
162 = FLANGE WIDTH X 1/100 INCHES I.E. 15/8" SECTION B-B SECTION A-A
54 = MINIMUM STEEL THICKNESS IN MILS (1/1000 INCHES) I.E. 0.054"
MINIMUM STEEL YIELD STRENGTH I.E. 50 KSI 4
_______________
4) ALL COLD FORMED STEEL SHAPES AND ACCESSORIES SHALL BE GALVANIZED - G60 COATING. S101
5) THE DESIGN INTENT FOR THESE ELEMENTS IS THAT THEY BE ATTACHED TO EACH OTHER AND TO
THE STRUCTURE TO BEHAVE AS A SYSTEM. INSTALL ACCESSORY ITEMS SUCH AS ANGLES, CLIPS, CFS STUD OPENING SCHED
10 9
STIFFENERS, STRAPS, ETC, DESIGNED AND RECOMMENDED BY THE MANUFACTURER, TO PROVIDE 1/8" = 1'-0"
4
_______________
1/
4X
A COMPLETE, STABLE SYSTEM - ALL ACCESSORIES MAY NOT BE INDICATED ON THE DRAWINGS. S101
4X
6) INSTALL SUPPLEMENTARY FRAMING, BLOCKING, ETC TO SUPPORT FIXTURES AND OTHER ITEMS
SS
PROVIDED BY OTHER TRADES.
H
7) FASTEN ELEMENTS AND ACCESSORIES BY WELDING OR SELF DRILLING SCREWS (#10 MINIMUM). 1/4
INSTALL SCREWS AT 1/2" MINIMUM EDGE DISTANCE AND AT 3/4" MINIMUM SPACING. C PL3/8X
8) PROVIDE HEADERS FOR ALL OPENINGS PER SCHEDULE. 6
_______________ CAP PL1/4 AT
1 1/2"
9) INSTALL HORIZONTAL BRIDGING IN STUD WALLS AT 4.5 FEET AND INTERMEDIATE JOIST BRIDGING S101 TOP OF COL
AT MIDSPAN OR 10 FOOT MAXIMUM SPACING.
3 SPA 3"
EXISTING W16X31 BELOW, VERIFY IN FIELD
HSS4X4 POST MUST CENTERED OVER THE WEB
@ 3"
OF THE EXISTING W16X31 BEAM (+/-1/4")
1 1/2"
W BEAM,
1 STRUCT SECOND FLOOR L3X3X3/16 1 3/4"
SEE PLAN
S101 1/8" = 1'-0" 3/4"Ø T/C BOLTS W/ HARDENED
WASHERS, SEE SCHEDULE FOR
1/2"
5 1/4" MAX 14 GA ANGLE W/ #8 NUMBER OF BOLTS
(13) SCREWS AS SHOWN
EQ EQ
W BEAM, HSS COL, SEE BEAM # OF
SEE PLAN 20 GA STUDS ES @ 16" PLAN SIZE BOLTS
OC. PROVIDE VERTICAL
SLIP CONNECTION AT W8/W10 2
HANGER ROOF DECK REV. FECHA DESCRIPCION
W12/W14 3
RODS
W16 4 APROBADO
W18 5
W21 6
COLUMN OVER CFS WALL TYPICAL BLOCKING Structural Framing Plan and DE
3 W BEAM-W COL CONN DETAIL 4 BEAM CONNECTION 6 ATTACHMENT TO HSS POST 7 AND STRAPPING DETAIL 11 MTL STUD TO DECK Details
S101 1 1/2" = 1'-0" S101 1 1/2" = 1'-0" S101 1 1/2" = 1'-0" S101 3/4" = 1'-0" FECHA ESCALA
S101 1" = 1'-0"
2016.09 As indicated