INTELLIGENT TEMPERATURE MONITORING AND CONTROL


SYSTEM USING AVR MICROCONTROLLER
Posted on August 2, 2012 by R-B 13 comments   |   

Controlling temperature has been a prime objective in various applications including refrigerators, air
conditioners, air coolers, heaters, industrial temperature conditioning and so on. Temperature
controllers vary in their complexities and algorithms. Some of these use simple control techniques like
simple on-off control while others use complex Proportional Integral Derivative (PID) or fuzzy logic
algorithms. In this project I’m going to discuss about a simple control algorithm and utilize it
intelligently unlike analogue controllers. Here are the features of our controller:

1. Audio-visual setup for setting temperature limits.


2. Fault detection and evasive action.
3. Temperature monitoring and display.
4. Audio-visual warning.
5. System status.
6. Settable time frame.
7. Data retention with internal EEPROM memory.

Intelligent temperature controller

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 1/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

For this design I used an ATMega32L AVR microcontroller with an internal clock frequency of 8MHz, a
4×20 LCD for presenting data visually, a 4-button input interface, a tiny piezo sounder for audible
indications and some LEDs for showing faults and simulating real-life devices like heater and coolers. I
used MikroC for AVR compiler from Mikroelektronika to develop the firmware for this controller.

Hardware

The hardware consists of a four-button interface, four LEDs, a piezo tweeter or sounder, a 4×20 LCD, a
LM35 temperature sensor, an AVR ATMega32L microcontroller and some other passive parts. Two
LEDs connected to PORTD0 and PORTD1 pins simulate on and off operation of relay switches that are
actually present in actual applications to control a heater and an air conditioner. The hardware is
powered by a 5V source preferably with a 5V regulator like 7805. If relays are used then a 12/24V
source will also be needed to power the relays. The AVR micro’s AVREF and AVCC pins should be both
connected to the 5V source. The distance between the LM35 sensor and the AVRs ADC pin must not be
greater than 10-12cm for proper temperature reading. Though I did this project in a prototyping board
made with a strip board, a PCB version is more preferred. Two additional LEDs connected to PD2 and
PD3 indicates the failure or malfunctioning status of the air conditioner and the heater.

Microcontroller and display circuit

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 2/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

Input/Output circuit

Firmware

The entire firmware relies on logical decisions at every step. I wrote the code in a way that the
complete code is divided into understandable small functional blocks or functions. Each of these
functions is doing specific tasks.

Starting from the top of the code, I declared some definitions of port pins, LCD pins and EEPROM
locations. Next I declared global variables and function prototypes.

I’m now going to explain the tasks each functions do. The first function that’s called in the main()
function is the setup_mcu()function. It configures the I/O ports for general tasks, LCD and audio
output pin. It also sets flags “c” and “h” zero. These flags are set whenever the system faces an
alarm. “h” means heater fault flag and “c” means cooler fault flag.  Next to the setup_mcu() function is
the scan_keys() function which simple reads the buttons and a generate specific tone for the key
pressed and return a specific value for that particular key. Thus key press, key debouncing delays and

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 3/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

tone generation accompanied with key press is made universal throughout the entire code.
The  adc_avg() function takes 64 samples of channel 0 of the AVR’s built-in ADC and makes the average
of these samples to reduce noise and ensure accuracy. This function returns an unsigned long value
since 10-bit ADC resolution is used. Following the adc_avg() function is the temperature display
function temp_display(). All it does is simply show the current value of the temperature on the LCD
display. The settings() function is the most important part of the program. When entered this function
has two menus. The first one according to the program is the reset fault service request and the
second allows the user to setup the high and low temperature values along with the number of passes
that will be allowed for the temperature to reach the nominal value. Whenever these values are
exceeded an alarm goes high and a particular temperature control device (heater or cooler) is set.
Thus setting the right values ensure proper system operation and avoid false alarms.
The inc_dec function is used for the menu operations whenever when we need to change a value. It is
called to setup temperature values and pass values. The display_common function is used for
common display purposes as needed in the inc_dec function. Next the compare_temp() routine
compares temperature and shows a message in the LCD if the temperature is within limit or beyond
limit. Another important part of the program is the function called controller_state. It is here the
controller sets on or off the temperature control devices and also generates alarm in the event of any
error. Associated with this routine is the check_fault routine when the conditions for fault are checked.
The read_memory routine reads the stored data for temperature limits and others in the AVR internal
EEPROM. Finally the last three functions of the code are fault_messages() which shows the fault type,
light the specific LED the specific fault and generate a warning tone for all
faults; settings_demanded() calls for settings menu and all_tasks() is the collection of all the tasks done
in the main function.

Here’s the complete mikroC AVR code:

#define setup PINB0_bit


#define up PINB1_bit
#define down PINB2_bit
#define save PINB3_bit

#define heater PORTD0_bit


#define cooler PORTD1_bit
#define Fault_H PORTD2_bit
#define Fault_C PORTD3_bit

#define ee_t_high 0x0


#define ee_t_low 0x4
#define ee_t_delta 0x8
#define ee_pass_times 0xE

sbit LCD_RS at PORTC2_bit;


sbit LCD_EN at PORTC3_bit;
sbit LCD_D4 at PORTC4_bit;
sbit LCD_D5 at PORTC5_bit;
sbit LCD_D6 at PORTC6_bit;
sbit LCD_D7 at PORTC7_bit;

sbit LCD_RS_Direction at DDC2_bit;


sbit LCD_EN_Direction at DDC3_bit;
sbit LCD_D4_Direction at DDC4_bit;
http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 4/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

sbit LCD_D5_Direction at DDC5_bit;


sbit LCD_D6_Direction at DDC6_bit;
sbit LCD_D7_Direction at DDC7_bit;

bit h;
bit c;
float t=0.0;
float temp=0.0;

unsigned long pass=0;


unsigned int t_low=0;
unsigned int t_high=0;
unsigned int t_delta=0;
unsigned char pass_times=0;

void setup_mcu();
unsigned char scan_keys();
unsigned long adc_avg();
void temp_display();
void settings();
signed int inc_dec(signed int variable,signed int max,signed int min,u
void display_common(unsigned char x,unsigned char y,unsigned char conv
void compare_temp();
void controller_state(unsigned short state);
void check_fault(unsigned short stat);
void read_memory();
void fault_messages();
void settings_demanded();
void all_tasks();

void main()
{
setup_mcu();
read_memory();
while(1)
{
all_tasks();
};
}

void setup_mcu()
{
Lcd_Init();
Sound_Init(&PORTD,4);
Lcd_Cmd(_LCD_CLEAR);
Lcd_Cmd(_LCD_CURSOR_OFF);
DDRD=0xFF;
PORTD=0x00;
DDRB=0x00;
c=0;
h=0;
}

unsigned char scan_keys()


{
if(setup)
{
Sound_Play(888,99);
return 1;
}
else if(up)
{
Sound_Play(900,9);
return 2;
}

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 5/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

else if(down)
{
Sound_Play(700,9);
return 3;
}
else if(save)
{
Sound_Play(800,99);
return 4;
}
else
{
return 0;
}
}

unsigned long adc_avg()


{
unsigned char sample=0;
register unsigned int adc=0;
for(sample=0;sample<64;sample++)
{
adc+=((float)ADC_Read(0));
delay_us(20);
}
adc=adc>>6;
return adc;
}

void temp_display()
{
register unsigned long conv=0;
unsigned char ch=0;
t=((adc_avg())*48.9);
temp=(t*0.01);
conv=t;
ch=(conv/1000);
Lcd_Chr(2,1,(48+ch));
ch=((conv/100)%10);
Lcd_Chr_CP((48+ch));
Lcd_Chr_CP(46);
ch=(conv/10)%10;
Lcd_Chr_CP(48+ch);
ch=(conv)%10;
Lcd_Chr_CP(48+ch);
Lcd_Out_CP("'C");
Delay_ms(100);
}

void settings()
{
Lcd_Cmd(_LCD_CLEAR);
read_memory();

if(h||c)
{
lcd_out(1,1,"Reset Alarm? ");
lcd_out(2,1,"Up=Yes Down=No");
do
{
if(scan_keys()==2)
{
c=0;
h=0;
break;

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 6/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

}
if(scan_keys()==3)
{
break;
}
}while(1);
}
Lcd_Cmd(_LCD_CLEAR);
delay_ms(500);

lcd_out(1,1,"Settings Step 1/3 ");


lcd_out(2,1,"High Temp. Limit:");
lcd_out(3,4,"'C");
t_high = inc_dec(t_high,99,0,1,3);
if((t_high>=0)&&(t_high<=99))
{
eeprom_write(ee_t_high,t_high);
Lcd_Cmd(_LCD_CLEAR);
}
delay_ms(500);
lcd_out(1,1,"Settings Step 2/3");
lcd_out(2,1,"Low Temp. Limit:");
lcd_out(3,4,"'C");
t_low=inc_dec(t_low,99,0,1,3);
if(t_low>=0 && t_low<=99)
{
eeprom_write(ee_t_low,t_low);
Lcd_Cmd(_LCD_CLEAR);
}
delay_ms(500);
lcd_out(1,1,"Settings Step 3/3");
lcd_out(2,1,"No. of passes: ");
pass_times=inc_dec(pass_times,99,0,1,3);
if(pass_times>=0 && pass_times<=99)
{
eeprom_write(ee_pass_times,pass_times);
Lcd_Cmd(_LCD_CLEAR);
}
delay_ms(500);
pass_times=(eeprom_read(ee_pass_times));
t_high=(eeprom_read(ee_t_high));
t_low=(eeprom_read(ee_t_low));
t_delta=(((t_high-t_low)/2));
eeprom_write(ee_t_delta,t_delta);
delay_ms(100);
}

signed int inc_dec(signed int variable,signed int max,signed int min,u


{
do
{
display_common(x,y,variable);
if(scan_keys()==2)
{
variable+=1;
}
if(scan_keys()==3)
{
variable-=1;
}
if(variable>max)
{
variable=min;
}
if(variable<min)

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 7/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

{
variable=max;
}
if(scan_keys()==4)
{
return variable;
}
if(scan_keys()==1)
{
return (max+1);
}
}while(1);
}

void display_common(unsigned char x,unsigned char y,unsigned char conv


{
unsigned char t = 0;
t=(convert/10);
Lcd_Chr(y,x,(48+t));
t=(convert%10);
Lcd_Chr(y,(++x),(48+t));
}

void compare_temp()
{
if(temp>=t_high)
{
Lcd_Out(3,1,"High Temperature!");
controller_state(1);
}
if(temp<=t_low)
{
Lcd_Out(3,1,"Low Temperature! ");
controller_state(2);
}
if(((temp<t_high)&&temp>=(t_high-t_delta))||((temp&
{
Lcd_Out(3,1,"Within Limit. ");
controller_state(0);
}
}

void controller_state(unsigned short state)


{
if(state==1)
{
if(c==0)
{
heater=0;
cooler=1;
check_fault(1);
}
}
else if(state==2)
{
if(h==0)
{
heater=1;
cooler=0;
check_fault(2);
}
}
else
{
heater=0;

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 8/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

cooler=0;
}
}

void check_fault(unsigned short stat)


{
if(stat==1)
{
pass++;
if((temp>=t_high)&&(pass==(pass_times*10)))
{
Fault_C=1;
c=1;
heater=0;
cooler=0;
pass=0;
}
if((temp<=(t_high-t_delta))&&(pass==(pass_times*1
{
heater=0;
cooler=0;
c=0;
pass=0;
}
}
if(stat==2)
{
pass++;
if((temp<=t_low)&&(pass==(pass_times*10)))
{
Fault_H=1;
h=1;
heater=0;
cooler=0;
pass=0;
}
if((temp>(t_low+t_delta))&&(pass==(pass_times*10)
{
heater=0;
cooler=0;
h=0;
pass=0;
}
}
delay_ms(100);
}

void read_memory()
{
pass_times=(eeprom_read(ee_pass_times));
delay_ms(30);
t_high=(eeprom_read(ee_t_high));
delay_ms(30);
t_low=(eeprom_read(ee_t_low));
delay_ms(30);
if(pass_times>99)
{
eeprom_write(ee_pass_times, 45);
delay_ms(30);
pass_times=(eeprom_read(ee_pass_times));
delay_ms(30);
}
if(t_high>99)
{
eeprom_write(ee_t_high, 40);

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 9/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

delay_ms(30);
t_high=(eeprom_read(ee_t_high));
delay_ms(30);
}
if(t_low>99)
{
eeprom_write(ee_t_low, 20);
delay_ms(30);
t_low=(eeprom_read(ee_t_low));
delay_ms(30);
}
t_delta=(((t_high-t_low)/2));
eeprom_write(ee_t_delta,t_delta);
delay_ms(30);
}

void fault_messages()
{
if((h==0) && (c==0))
{
Lcd_Out(4,1,"System Okay. ");
Fault_C=0;
Fault_H=0;
}
if((h==1) || (c==1))
{
Sound_Play(550,150);
if((h==1) && (c==0))
{
Lcd_Out(4,1,"Alarm! Heater Fault.");
delay_ms(600);
}
else if((h==0) && (c==1))
{
Lcd_Out(4,1,"Alarm! Cooler Fault.");
delay_ms(600);
}
else if((h==1) && (c==1))
{
Lcd_Out(4,1,"System Failed. ");
delay_ms(600);
}
}
}

void settings_demanded()
{
if(scan_keys()==1)
{
delay_ms(9);
while(scan_keys()==1);
settings();
};
}

void all_tasks()
{
Lcd_Out(1,1,"Active Temperature: ");
temp_display();
fault_messages();
settings_demanded();
compare_temp();
}

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 10/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

Download source and HEX files 

Operation

The system works as described here. Upon start-up the system sets up the required internal hardware
of the AVR micro and then read the EEPROM memory. If the EEPROM locations contain garbage values
then they are set with default values otherwise the previously stored values are read. After reading the
EEPROM, the system starts to monitor temperature and waits for actions if any temperature limit is
exceeded. The system at this point shows current temperature and system status. If the user wishes to
set parameters then he/she has to press the setup button and enter the settings menu. In the settings
menu there are three settings and these are high and low temperature limits and the number of
passes the system will make prior to issuing a fault message. If, for example, the high temperature
limit is set to 40?C, the low temperature limit is set to 20?C and the number of system passes is set to
45, and the current temperature gradually rises to 41?C from 30?C, the system will trip high
temperature alarm and start the cooler. The LCD display will show high temperature alarm. Now if the
temperature starts to decline and reach a value in between (40?C – (40?C -20?C)/2) =30?C [i.e t_delta]
and 20?C within the 45 system passes then the cooler is turned off and no fault message is generated.
The system resumes to normal state. If the temperature didn’t decline to the range mentioned as
above then it is assumed that the cooler is either faulty or some other thing is causing too much heat
generation which is exceeding the cooler’s capacity. Thus a fault warning is issued for the cooler and it
is shut down until the fault has been cleared. In this way both the hardware and the cooler is
protected from damage. The same scenario happens during the low temperature alarm. If both the
cooler and the heater fail then the system goes in a complete halt state until reset or given attention.

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 11/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 12/13
07/11/2018 Intelligent temperature monitoring and control system using AVR microcontroller - Embedded Lab

http://embedded-lab.com/blog/intelligent-temperature-monitoring-and-control-system-using-avr-microcontroller/ 13/13

Potrebbero piacerti anche