Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
CONTACTRON
Matthias Borutta
Product Marketing
BU INTERFACE
1
CONTACTRON
How to operate a motor ?
coils
contactors versus
depletion layer
electronics
2
CONTACTRON
Motor control with mech. contactors
?
L1 L2 L3
PLC
K1
Contactor
U V W PE
Motor
3
CONTACTRON
Motor control with reversing contactor
L1 L2 L3
K1 K2
U V W PE
4
CONTACTRON
Motor control with Electronic Load Relays ELR
control part L1 L2 L3 load part
supply 24 V DC locking
separation
stabilizing down time
U1 V1 W1
Motor
5
CONTACTRON
The program
7
CONTACTRON
1 phase solid state contactor
Design contactless – wear free
Output Applications
I
50A
ELR 1/50-660
30A
ELR 1/30-660
9
CONTACTRON
3 phase solid state contactor
22,5 - 147,5mm
Output
3 x 2A, 3x9A, 3x16A and 3x37A
R
L
Input
10
CONTACTRON
Solid state contactor
Advantages:
11
CONTACTRON
Solid state contactor
Customer benefits:
12
CONTACTRON
CONTACTRON – “4 in 1” – Hybrid technology
14
CONTACTRON
Mech. reversing contactor circuitry for Cat3
Main circuit
F1
L1
F2
L2
F3
L3
K1
Emergency stop contactor
K2
Emergency stop contactor
M1 PE
15
CONTACTRON
Motor protection relay
18
CONTACTRON
Motor protective circuit-breaker
19
CONTACTRON
Comparison
24 min. 8 min.
70 clamping points 23 clamping points
20
CONTACTRON
Comparison
21
CONTACTRON
“4 in 1” Reversing contactor circuitry for Cat3
L1 L2 L3
K1
T1 T2 T3
M
3~
M1 PE
22
CONTACTRON
CONTACTRON – “4 in 1” – functions and features
„four in one“
24
CONTACTRON
“4 in 1” – functions and features
Voltage 550 V AC
Current 3 x 9 A or 3 x 2 A
26
CONTACTRON
Princip hybrid circuit “4in1
L1 L2 L3
First two relays define the rotation direction for the
K1 K1 K2
motor. (Here not marked)
The currents I1, I2 and I3 are 0.
K2
V1 V2
K3 K3
I2
I1 I3
M
CONTACTRON
Princip hybrid circuit “4in1
L1 L2 L3
After that the relay K1 and K2 close.
K1 K1 K2
K3 K3
I2
I1 I3
M
CONTACTRON
Princip hybrid circuit “4in1
L1 L2 L3
Now both semiconductor V1 and V2 switch on.
K1 K1 K2
K3 K3
I2
I1 I3
M
CONTACTRON
Princip hybrid circuit “4in1
L1 L2 L3
The relay K3 bridge the semiconductor to
K1 K1 K2
reduce the power loss (bypass).
After that the semiconductor „sleep“.
At the switch off the process reverse. K2
I3
M
CONTACTRON
“4 in 1” – approvals
Maritime approvals
GL, Bureau Veritas, Lloyd Reg. of
Shipping, American Bureau of Ship. etc.
ATEX, EX (PTB)
UL and CSA
= + +
ELR „4 in 1“ Reversing contactor Motor protection Emergency stop
combination relay contactor
32
CONTACTRON
“4 in 1”
33
CONTACTRON
34
CONTACTRON
Application Sample
35
CONTACTRON
Application Sample
36
CONTACTRON
Application Sample
37
CONTACTRON
Application Sample
Auxilary drives
Conveyor belts
Swarf conveyors
Filter systems
Oil fume extractor
38
CONTACTRON
customers - applications
39
CONTACTRON
customers - applications
Hoppe
Bordmesstechnik
(ship building)
HEW
(steeple bell machines)
Wincor Nixdorf
(PET-bottle machines)
Witron
(logistics systems)
Test application
Kannegiesser
(laundry machines)
40
CONTACTRON
customers - applications
Siemens
Conveyor systems for airports and hospitals
Distribution/wholesaler
Bürkle
Rexel
RS Components
Sonepar
41
CONTACTRON