Sei sulla pagina 1di 11

SPECIFICATION AND SCHEDULE OF QUANTITIES

SL DESCRIPTION QTY UNIT RATE AMOUNT


5 BRICK WORK

NOTE : Unless otherwise specified, rates applied


for all items will include the following :-

All scaffolding, ladders, platforms, staging


1 and plant required in the execution of the
work.

Hacking or roughening of concrete or


2 other surface in contact with masonry for
bondage.

3 Raking out joints to specified depth either


for plastering or jointing.

4 Levelling up and preparing top of


masonry for damp proof course.

5 Building in hold fasts and such other


inserts.

6 Keeping the work well wetted for two


weeks.

7 Providing through bond stones 2m apart


in each course in stone masonry.

8 Work at all heights and depths unless


otherwise specified.

9 Curing with water for a minimum period


of 10 days

Solid block masonry using pre cast solid


blocks (Factory made) of size
40x20x20cm or nearest available size
5.1 confirming to IS 2185 part I of 1979 for
super structure above floor two level up
to floor V level thickness 20cm and above
in: CM 1:6 (1 cement : 6 coarse sand) etc
complete
Observed Data
5.1.a Ground Floor 24.83
5.1.b First Floor 55.13
5.1.c Second Floor 55.13
5.1.d Third Floor 55.13
5.1.e Fourth Floor 55.13
5.1.f Fifth Floor 55.13
5.1.g Sixth Floor 22.48
5.1.h Terrace Floor 18.76
5.1.i Lift Room 8.47

Total 350.20 CUM 6400.00 2241288.192

Solid block masonry using pre cast solid


blocks (Factory made) of size
40x20x10cm or nearest available size
5.2 confirming to IS 2185 part I of 1979 for
super structure above floor two level upto
floor five level with thickness 15cm in: CM
1:6 (1 cement : 6 coarse sand) etc
complete
Observed Data
5.2.a Ground Floor 5.38
5.2.b First Floor 14.98
5.2.c Second Floor 14.98
5.2.d Third Floor 14.98
5.2.e Fourth Floor 14.98
5.2.f Fifth Floor 14.98
5.2.g Sixth Floor 6.11
5.2.h Terrace Floor 15.23

Total 101.61 CUM 7000.00 711273.5

WOOD/ALUMINIUM WORK

NOTE : Unless otherwise specified, rates applied


for all items will include the following :-

Hold fasts of flat iron 300x40x5mm size


welded or screwed to the frame
1 embedded in concrete 1:3:6,
250x100/150mm, 200x150mm in the
support walls, 6nos. of holdfasts for doors
and 4nos. for windows.

First class well seasoned anjili wood or


equivalent country wood will be used for
2
all works. Documentary proof of factory
seasoning of wood brought to site to be
produced when called for.

3 Shall include the cost of the following


fittings for doors and windows.

a) 3/4 nos. of MS oxidised hinges of 150 /


75mm size for each door shutter /
windows.
Shall include only fixing charges of hasp
4 and staples, bath room latches, nylon
bush, door stopper, tower bolt, handles,
magnetic door catch, magic eye, pad
lock, aldrops, hook and eye, aldrops, door
closures etc., fixtures supplied by client

5 Sizes mentioned are finished sizes.

6 Work at all heights.

Providing and fixing 37 mm thick factory


made PVC Door shutter, styles and rails
made of PVC hollow extruded printed and
laminated section having overall
6
dimension 115 mm x 37 mm with wall
thickness 2 mm (± 0.2 mm) with inbuilt
beading on one side, the styles and rails
mitred cut and joint at corners by
inserting 2 nos PVC profile reinforcement
of size 75 mm x 200 mm long with cross
section size of 28 mm x 30 mm having
wall thickness 2 mm (± 0.2 mm).

Styles, rails and reinforcements to be


fusion welded together. Only hinge side
vertical style to be reinforced with PVC
profile reinforcement in full length.
Printed and laminated PVC lock rail of size
110 mm x 37 mm having wall thickness 2
mm (± 0.2 mm) to be welded horizontally
with the vertical styles after inserting

PVC profile reinforcement as in styles


and rails, providing with PVC snap fit
beading, panels of 100 x 20 mm printed
& laminated and inserting 2 nos 6 mm dia
bright steel rod horizontally with both
sidethreaded and tightened with check
nuts and washers complete, all asper
manufacturer's specification and direction
of engineer-in-charge.

PVC DOOR

Ground floor

First Floor

Second floor
Third Floor

Total RO SQM 1,600.00

Providing wood work in frames of doors,


windows, clerestory windows and other
7 frames, wrought framed and fixed in
position with hold fast lugs or with dash
fasteners of required dia & length ( hold
fast lugs ordash fastener shall be paid for
separately).
C.P.W.D spec DSR code Clause 9.1.2
75558.6

Providing and fixing panelled or panelled


and glazed shutters for doors, windows
and clerestory windows, including ISI
marked M.S. pressed butt hinges bright
finished of required size with necessary
screws, excluding panelling which will be
paid for separately, all complete as per
direction of Engineer-in-charge.
C.P.W.D spec DSR code Clause 9.5.2.2
1581
FOR FRAME & SHUTTER
DOORS

7.1 First quality Teak wood door & shutter


with approved design and specification
Main Door ( 120 cm x 225cm )
Ground Floor 2.00
First Floor 1.00
Second Floor 1.00
Third Floor 1.00
Fourth Floor 1.00
Fifth Floor 1.00
Sixth Floor 0.00
Terrace Floor 0.00
Lift Floor 0.00

Total 7.00 Nos 35000.00 245000


Main Door ( 110 cm x 225 cm )
Ground Floor 0.00
First Floor 4.00
Second Floor 4.00
Third Floor 4.00
Fourth Floor 4.00
Fifth Floor 4.00
Sixth Floor 2.00
Terrace Floor 0.00
Lift Floor 0.00
Total 22.00 Nos 34000.00 748000

First quality compressed wood door &


7.2 shutter with approved design and
specification
Door ( 100 cm x 225 cm )
Ground Floor 0.00
First Floor 0.00
Second Floor 0.00
Third Floor 0.00
Fourth Floor 0.00
Fifth Floor 0.00
Sixth Floor 0.00
Terrace Floor 1.00
Lift Floor 0.00

Total 1.00 Nos 22000.00 22000

Door 1 ( 90 cm x 225 cm )
Ground Floor 3.00
First Floor 13.00
Second Floor 13.00
Third Floor 13.00
Fourth Floor 13.00
Fifth Floor 13.00
Sixth Floor 5.00
Terrace Floor 0.00
Lift Floor 1.00

Total 74.00 Nos 20000.00 1480000


Door 2 ( 75 cm x 225 cm )
Ground Floor 1.00
First Floor 8.00
Second Floor 8.00
Third Floor 8.00
Fourth Floor 8.00
Fifth Floor 8.00
Sixth Floor 4.00
Terrace Floor 0.00
Lift Floor 1.00

Total 46.00 Nos 18000.00 828000


Fire Door ( 120 cm x 225 cm )
Ground Floor 1.00
First Floor 1.00
Second Floor 1.00
Third Floor 1.00
Fourth Floor 1.00
Fifth Floor 1.00
Sixth Floor 1.00
Terrace Floor 1.00
Lift Floor 0.00
Total 8.00 Nos 14290.00 114320

SD ( 150 cm x 225 cm )
Ground Floor 1.00
First Floor 1.00
Second Floor 1.00
Third Floor 1.00
Fourth Floor 1.00
Fifth Floor 1.00
Sixth Floor 1.00
Terrace Floor 1.00
Lift Floor 0.00

Total 8.00 Nos 17850.00 142800


SD ( 240 cm x 225 cm )
Ground Floor 1.00
First Floor 1.00
Second Floor 1.00
Third Floor 1.00
Fourth Floor 1.00
Fifth Floor 1.00
Sixth Floor 1.00
Terrace Floor 1.00
Lift Floor 0.00

Total 8.00 Nos 28600.00 228800

Providing and fixing aluminium work for


doors, windows, ventilatorsand partitions
with extruded built up standard tubular
8 sections/appropriate Z sections and other
sections of approved makeconforming to
IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size,
including necessary filling up the gaps
atjunctions, i.e. at top, bottom and sides
with required EPDM rubber/neoprene
gasket etc.

Aluminium sections shall be smooth,


rustfree, straight, mitred and jointed
mechanically wherever requiredincluding
cleat angle, Aluminium snap beading for
glazing / paneling,C.P. brass / stainless
steel screws, all complete as per
architecturaldrawings and the directions
of Engineer-in-charge. (Glazing,
panelingand dash fasteners to be paid for
separately)
C.P.W.D spec DSR code Clause21.3.1
FOR FRAME & SHUTTER
WINDOWS ( Aluminium Works)
Ground Floor 5.58
First Floor 32.93
Second Floor 31.85
Third Floor 31.85
Fourth Floor 31.13
Fifth Floor 31.13
Sixth Floor 24.29
Terrace Floor 0.00
Lift Floor 0.00

Total 188.74 SQM 4560.00 860665.8

Providing and fixing bright finished brass


9 tower bolts (barrel type) with necessary
screws etc. complete : 250x10 mm
C.P.W.D spec DSR code Clause 9.74.1
TOWER BOLTS
9.a Ground Floor 6.00
9.b First Floor 54.00
9.c Second Floor 54.00
9.d Third Floor 54.00
9.e Fourth Floor 54.00
9.f Fifth Floor 54.00
9.g Sixth Floor 18.00
9.h Terrace Floor 4.00
9.i Lift Floor 2.00

Total 300.00 NOS 410.00 123000

Providing and fixing aluminium handles,


ISI marked, anodised (anodic coating not
10
less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour or
shade, with necessary screws etc.
complete
C.P.W.D spec DSR code Clause 9.100.1
HANDLES
10.a Ground Floor 6.00
10.b First Floor 54.00
10.c Second Floor 54.00
10.d Third Floor 54.00
10.e Fourth Floor 54.00
10.f Fifth Floor 54.00
10.g Sixth Floor 18.00
10.h Terrace Floor 4.00
10.i Lift Floor 2.00

Total 300.00 NOS 180.000 54000


Providing and fixing aluminium work for
doors, windows, ventilatorsand partitions
with extruded built up standard tubular
11 sections/appropriate Z sections and other
sections of approved makeconforming to
IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size,
including necessary filling up the gaps
atjunctions, i.e. at top, bottom and sides
with required EPDM rubber/neoprene
gasket etc.

Aluminium sections shall be smooth,


rustfree, straight, mitred and jointed
mechanically wherever requiredincluding
cleat angle, Aluminium snap beading for
glazing / paneling,C.P. brass / stainless
steel screws, all complete as per
architecturaldrawings and the directions
of Engineer-in-charge. (Glazing,
panelingand dash fasteners to be paid for
separately)
C.P.W.D spec DSR code Clause21.3.1
ALUMINIUM VENTILATORS
11.a Ground Floor 0.00
11.b First Floor 1.08
11.c Second Floor 1.08
11.d Third Floor 1.08
11.e Fourth Floor 1.08
11.f Fifth Floor 1.08
11.g Sixth Floor 1.06

Total 6.46 SQM ### 29457.6

Supplying and fixing rolling shutters of


approved make, made of required size
M.S. laths, interlocked together through
12 their entire length andjointed together at
the end by end locks, mounted on
specially designedpipe shaft with
brackets, side guides and arrangements
for inside andoutside locking with push
and pull operationcompleteIncluding
thecost of providing

and fixing necessary 27.5


cmlongwirespringsmanufactured from
high tensile steel wire of adequate
engthconforming to IS: 4454 - part 1 and
M.S. top cover of required thicknessfor
rolling shutters.
80x1.25 mm M.S laths with 1.25 mm
thick top cover

ROLLING SHUTTER

Basement floor RO

Total RO SQM

PLASTERING

NOTE :

1 Hacking or scarifying concrete surface to


be plastered or rendered.

2 Preparation of surfaces by raking out


joints, wetting the surface etc.

Providing grooves at the junction of


3
masonry and concrete members
wherever different materials are
connected and also wherever necessary.

4 Providing drip moulds as size mentioned


wherever necessary.( 40 x 15 )

7 Washing floors, cleaning glass and


levelling premises clean and tidy.

5 Curing with water for a minimum period


of 14 days.

Finishing of chasing/grooving etc., done


6 by other agencies using necessary
expanded metal plaster mesh.

7 Necessary scaffolding, ladder, platform


etc., for any height and depth.
Work at all heights and depths.

Rate to include providing Arpitha or


8 equivalent make expanded metal plaster
mesh of required width for Masonry and
RCC joints

12 mm cement plaster finished with a


13 floating coat of neat cement of mix:1:4 (1
cement: 4 fine sand)
C.P.W.D spec DSR code Clause13.7.2
13.1 External plastering
13.1.a Ground Floor 190.86
13.1.b First Floor 303.14
13.1.c Second Floor 303.14
13.1.d Third Floor 303.14
13.1.e Fourth Floor 303.14
13.1.f Fifth Floor 303.14
13.1.g Sixth Floor 130.31
13.1.h Terrace Floor 390.30
13.1.i Lift Floor 126.30
Total 2353.49 SQM 333.000 783711.504
13.2 Internal plastering
13.2.a Ground Floor 214.56
13.2.b First Floor 983.07
13.2.c Second Floor 983.07
13.2.d Third Floor 983.07
13.2.e Fourth Floor 983.07
13.2.f Fifth Floor 983.07
13.2.g Sixth Floor 154.69
13.2.h Terrace Floor 57.65
13.2.i Lift Floor 46.50
Total 5388.77 SQM 280.000 1508856.02

Cement plaster 1:3 (1 cement: 3 coarse


14 sand) finished with a floating coat of neat
cement.
C.P.W.D spec DSR code Clause 13.9.1
Ceiling plastering
14.a Ground Floor 349.92
14.b First Floor 323.83
14.c Second Floor 323.83
14.d Third Floor 323.83
14.e Fourth Floor 323.83
14.f Fifth Floor 323.83
14.g Sixth Floor 115.19
14.h Terrace Floor 51.46
14.i Lift Floor 19.78
Total 2155.50 SQM 280.000 603541.12
Compund Wall
12 mm cement plaster finished with a
15 floating coat of neat cement of mix:1:4 (1
cement: 4 fine sand)
C.P.W.D spec DSR code Clause13.7.2

15.a Outside 264.28

Total 264.28 SQM 333.000 88005.24

15.b Inside 264.28

Total 264.28 SQM 280.000 73998.4

Cement plaster 1:3 (1 cement: 3 coarse


16 sand) finished with a floating coat of neat
cement.
C.P.W.D spec DSR code Clause 13.9.1
Top Surface 26.43

Total 26.43 SQM 280.000 7399.84

17 STEEL WORK

Providing and fixing hand rail bottom and


top for staircases/ balcony with bottom
17.1 made of M.S Round tube as per detailed
drawing (M.S tube (medium): 40 mm
nominal bore ) and top rail as specified
below:
C.P.W.D spec DSR code Clause10.26.1
17.1.a Ground Floor 64.58
17.1.b First Floor 85.38
17.1.c Second Floor 85.38
17.1.d Third Floor 85.38
17.1.e Fourth Floor 85.38
17.1.f Fifth Floor 85.38
17.1.g Sixth Floor 24.00

Total 5103.23 KGS 110.000 561355.1064

Providing and fixing M.S. grills of required


pattern in frames of ventilator setc. with
17.2 M.S. flats, square or round bars etc.
including priming coat with approved
steel primer all complete. (20 kg Per
Sqm )
C.P.W.D spec DSR code Clause 9.48.2
17.2.a Ground Floor 193.50
17.2.b First Floor 2394.95
17.2.c Second Floor 2394.95
17.2.d Third Floor 2394.95
17.2.e Fourth Floor 2394.95
17.2.f Fifth Floor 2394.95
17.2.g Sixth Floor 102.36
17.2.h Terrace Floor 90.00
17.2.i Lift Floor 40.50

Total 12401.11 KGS 155.000 1922172.05

Potrebbero piacerti anche