Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
LU
O
IN
STING S
No. 1
DER PRÜF
TE
TE
CHNIK IN
Test Probes
ICT / FCT
High Current
Cable and Plug Connectors
Assorted Applications
Catalogue 25.3
Competent in your field
Telecommunications
Information Electronics
Consumer Electronics
Automotive
Engineering
As the leading company in testing, INGUN has the largest range of spring-
loaded test probes worldwide. There is no doubt a spring-loaded test pro-
be for your application too. If not, contact us for your customised contac-
ting solution in renowned INGUN quality – Made in Germany.
2
Test Probes and Receptacles
Product
Tip Styles
Information Design and Instruction for Use
Bead Probe
Flying Probe
Fine Pitch
(Low ohm
test probes) Dipole / Four-wire HSS
Robust HSS
Press-in / Screw-in
Switching Probes Quick Exchange System
Four-wire Measurement
Dipole and
PCB Layout
RF Test Probes Plug Connectors
Pneumatic GKS
Pneumatic
Pneumatic Switching
Test Probes Probes
Interface GKS
Accessories
Contact Terminals
(GKS / test fixture) HMS / PCB Support GKS
4
About INGUN
Worldwide in Contact
IBERIA
INGUN SEA
5
Technical Information
www.ingun.com
6
Information
Product
Contents
Technical Information
Product Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Product Information
Fine Pitch
Functional Principles 12 - 13
components and functional units in order to test them. Design and Instructions
for Use 14 - 17
Materials and Environment 18
All relevant information about test probes and receptacles is
FAQ 19
featured and explained on the product information pages.
Stand. GKS
Metric
INGUN offers an unbeatable range of spring-loaded test
probes. Each product number has a defined key, which includes
relevant information about tip style, tip diameter, spring force
short / long
and material.
HSS
Depending on the electronic assembly and the test points to be
contacted, various test probe tip styles are available.
Robust HSS
Dipole HSS
The combination of the optimally selected test probe version
and spring force enables precise, reliable and replicable con-
tacting.
INGUN offers a range of tip styles for test points such as pads,
SKS
vias, pins, posts and plug connectors.
Step Probes
with spring-loaded plungers and recommended working stroke.
GKS ... M
The following points about test probes and receptacles are
described precisely in the design and instructions for use
section: assembly, available types of connection, hitting accura-
rotating GKS
VF / Non-
cy, current load capacity, drilling tolerances, life span and oper-
ating temperature range.
7
7
Technical Information
8
Information
Product
Technical Information
Standard
GKS
Bead Probe
e-type
Flying Probe
DKS
The choice of suitable tip style is one of the most important (oxidised, clean or contaminated by residue from the
Feinraster
factors in choosing the right test probe. Many of the tip sty- soldering process).
les can be used for several applications. A basic classification
can be made with respect to the geometry of the test points, Depending on the DUT and test conditions, it may be
such as pad, via, pin or posts. Furthermore, the test point necessary to try several tips styles and spring forces in
Metr. Stand.
can be differentiated by its size and surface condition order to find an optimal combination.
GKS
PADs
Contacting of flat test points on PCBs: To ensure the penetration of OSP or contaminated surfaces (residue from the sol-
dering process), aggressive, self-cleaning tip styles (e.g., tip style 91: dagger) are recommended. Passive tip styles are used
Kurz/Lang
HSS
for clean surfaces and to avoid puncturing the surface (e.g., tip style 05, bullet-nosed). Note: In order to avoid damaging
multi-layered PCBs, the penetration depth of the tip style in the external layer must be observed (especially when an ag-
gressive tip style is used together with a high spring force).
Dipol/Vierpol
Robust
1 4 5 7 8 9 13 14 15 17 24 33 38 77 89 91 93 97 98 Most commonly used
tip styles
SKS
VIAs Contact point Tip style
Vias can be contacted using the edge of a tip style on the inner surface of the
contaminated
Tip style number
self-cleaning
ring, or with the point of a crown tip style vertically on the surface of the via.
aggressive
GKS ... M
passive
POSTS
clean
PAD
VIA
PIN
Verdreges. GKS
003 x x x x
07 08 17 24 38 77 91 97 98 006 x x x x x
VF
01 x x x x x
02 x x x x
PINs 03 x x x x
An optimally-centred inverse cone tip style is recommended for pins and compo- 04 x x x x x x HF-Kontaktstifte
nent pins. Flat, pointed and tip styles with outer insulation are also possible for 05 x x x
Diplo-GKS
06 x x x x x
these kinds of test points. 07 x x x x x x
08 x x x x x x x
09 x x x x x x
13 x x x
14 x x x x x x x
15 x x x x x
Pneum.
GKS
17 x x x x x x
19 x x x x x x x
003 006 02 03 04 06 09 14 19 24 33 88 24 x x x x x x x
33 x x x x x x
38 x x x x x x
POSTS, screws and bolts 77 x x x x x x
Vielseitige
79 x x x x x
GKS
Self-centering tip styles, similar to those used for pins can be used for these kinds 88 x x x x x x
of test points 89 x x x x x
91 x x x x x x
93 x x x x
97 x x x x x x
Zubehör
98 x x x x x x
9
Tip Styles Overview
Tip Style 01 (self-cleaning 30° needle tip)
Commonly used, moderately aggressive tip for test pads.
10
Informationen
Information
Produkt
Product
Overview of Tip Styles
Standard
With this modified design of the tip style 03 an aggressive contacting contour in the
GKS
centre is created by applying cross grooves. Subsequently, a maximum of contacting
reliability is achieved when contacting component pins and wire-wrap posts.
Bead Probe
(self-cleaning 6-point crown with higher middle point) Tip Style 24
e-type
Universally used for practically all test points.
Flying Probe
(self-cleaning 3-point crown) Tip Style 33
DKS
A modified version of the 4-point self-cleaning crown (tip style 14), manufactured with
ground flanks, which creates a more aggressive tip. Can be used both for component
pins as well as test pads.
Feinraster
(self-cleaning 150° dagger) Tip Style 38
Comparable with tip styles 97 and 98, however with even flatter tip angle, for
contacting open vias and pads.
Metr. Stand.
GKS
(3-edged dagger) Tip Style 77
Universally used for plated open vias. Similar characteristics as tip style 91 (dagger),
however with three contacting edges instead of two. More stable tip, but therefore less
aggressive.
Kurz/Lang
HSS
(self-cleaning hexagonal flat spade) Tip Style 79
Multiblade tip style with self cleaning function.
Dipol/Vierpol
Robust
(self-cleaning 8-point crown) Tip Style 88
Self-cleaning crown with centring feature. Suitable for contaminated
component pins.
SKS
(self-cleaning 3-point crown) Tip Style 89
Recommended for unwashed PC boards. The unique shape of the steel tips ensures that
any contaminating particles migrate away from the contacting zone around the points.
GKS ... M
(self-cleaning dagger) Tip Style 91
Universally used and by far the most popular tip style. Very aggressive thus suitable
Verdreges. GKS
not only for plated open vias but also test pads.
VF
(3 x 22° tri-needle, pressed-in steel points) Tip Style 93
The three very aggressive HSS tips make this tip ideal for contacting unwashed
HF-Kontaktstifte
Diplo-GKS
Designed for plated open vias which are closed with sealing lacquer.
GKS
Comparable with tip style 97, also used for contacting open vias,
GKS
Standard serrated tip with higher-set outer nylon sleeve, designed for
component presence check. The designation “0”denotes nylon material,
the designation 06 denotes the inner tip style (example: 006 230 A).
Werkzeug
11
Technical Information
Functional Principles
Test Probes and Receptacles
spring loaded test probe (GKS) spring loaded test probe (GKS) tip with choice of
and receptacle (KS) plunger tip style
for plug-in connection barrel
(crimping points on side of the KS) spring
Spring-loaded test probes (GKS) normally consist of three The barrel accomodates the plunger and the spring. The
individual components. These components must be manu- actual measurement signal flows via the barrel to the recep-
factured with the level of precision the micro-electronics tacle. To improve the smooth movement, after gold-plating
industry demands. the barrel is treated with a very thin organic
protective layer.
The plunger features the contacting zone and is available
with a wide variety of tip styles. It must provide the smallest The receptacle (KS) enables easy exchange of test probes
possible contact resistance between the test probe and test during maintenance and servicing of the test fixture. The
point to ensure that measurement results are not distorted. exchange can be carried out quickly, and without the need
The most common plunger materials are steel and BeCu - for any wiring work. To enable this, crimp points are applied
both of which are hardened; brass is also used for passive tip to the side of the receptacle. Note: the crimp points only
styles. function properlywhen the receptacle has been inserted in
the assembly hole. This means that test probes can not be
The spring provides the contact pressure required for several mounting in receptacles which are not installed in the probe
hundred thousand working strokes (test cycles). The rated plate.
spring forces stated in the catalogue are reached at the
recommended working stroke and are subject to slight fluc-
tuations dependent on design, manufacturing tolerances,
and operating conditions.
12
Informationen
Produkt
Technical Information
.4
(14 test probes as well as the receptacles) or with the choice of
N
4,0
longer plungers (i.e. L versions for series GKS-050, 075 and
5,0
o z.) 100).
(10.0) .8
N (10
3,0
4,0
(14.4)
.1 o
z.) Collar height and installation height
N (8
5
2,2 oz )
.
3,0 (7.2
(10.8) 2,0N The installation height is the distance between the tip of the
z.)
2,0 1,5N
(5.4 o plunger of the non-activated test probe and the surface of
(7.2) .6 oz.) the probe plate. To regulate the installation height, the test
1,0N (3
1,0 oz.)
probes are normally available with various different collar
0,6N (2.2
(3.6) heights. In addition, spacers which offer further installation
height flexibility are available for some series. Test
0 1,0 2,0 3,0 4,0 5,0 6,0 Stroke in mm
probes with the end designation “00”
(.04) (.08) (.12) (.16) (.20) (.24) (inches) have no collar on the barrel. The
Installation Height
Collar Height
5 (.197)
13
Technical Information
INGUN receptacles
Profil
Profile
14
Information
Product
Technical Information
Standard
GKS
Bead Probe
e-type
Flying Probe
DKS
Wobble and minimum test point size
Feinraster
Due to the necessary play between the plunger and the bar-
rel of a test probe, the tip can be deflected out of the ideal
(i.e. vertical) position. This deflection, the so-called “wobb-
le”, was measured on INGUN test probes using a state-of-
Metr. Stand.
the-art optical measurement device. This machine can, upon
GKS
request, also be used to verify customised test fixtures. To
define the minimum test point size, the various tolerances of
the test fixture were also taken into consideration.
Kurz/Lang
It can generally be said that there is no direct correlation 0,05
HSS
between the wobble and the contacting accuracy of a test (.002)
probe. However, the position of the probe tip at the time of 0,1
actual contacting is especially important. For the subsequent (.004)
Dipol/Vierpol
stroke it is even often an advantage when the wobble is 0,15
Robust
higher, because this then helps to reduce the wear when the (.006)
plunger is pressed down into the barrel. Furthermore, the
likelihood of the test probe bending is reduced, thus prolon-
ging the life-expectancy. [Measurements in mm (inches)]
SKS
The following diagram shows the deflection of the plunger
from the ideal position (i.e. the centre of the assembly hole)
of various test probes. The experimental set-up used a stan-
dard INGUN probe plate, and the test probes were inserted
GKS ... M
into receptacles. The row of experimental tests was carried
out a number of times. Between each measurement the test
probes were activated a few times.
Verdreges. GKS
The result of the investigation offers no information about
VF
other factors, which must also be taken into consideration,
i.e. the tolerances of the PC board and of the test fixture
assembly as well as the uncertainties and errors, which can
HF-Kontaktstifte
Diplo-GKS
15
Technical Information
90,0
Upper limit (maximum permitted temperature)
The following diagram shows
80,0
the evaluation of a test probe
12,0 A of the series GKS-100 with a
70,0 BeCu plunger and 2,0 N spring
11,0 A
force.
10,0 A
Temperature [°C]
60,0
9,0 A
50,0
8,0 A
40,0
7,0 A
5,0 A
30,0
3,0 A
20,0
Measurement with GKS-100 307 090 A 20 00
10,0 (plunger material BeCu, 2N spring)
0,0
20
30
10
20
30
40
50
00
50
00
10
40
50
00
10
20
00
30
40
00
10
20
30
40
50
2:
2:
2:
2:
2:
2:
3:
3:
3:
0:
0:
0:
1:
1:
0:
0:
0:
1:
1:
1:
1:
3:
3:
3:
4:
Time [min]
Current loading
The transferable permanent current of test probes depends The maximum permitted current loading (see “Electrical data”
on the size of the components, the spring force and the of each product) was derived for each series in extensive
plunger material used. In the case of the plunger material, load tests. The test set-up called for the various test probe
the following is applicable: BeCu and brass plungers transfer series and spring forces to be loaded with a certain current,
higher currents then steel plungers. The permitted rated during which the temperature change of the test probe
currents are printed on each individual data sheet. These was measured. The increase of the current was applied in
values are valid at room temperature and for direct current increments of 1 - 2 Amps, but only as long as no temperature
from the stated standard spring force at working stroke. In the increase was registered.
case of alternating currents, the value must be reduced by the
factor 1 .
√2
16
Information
Product
Technical Information
Standard
GKS
Bead Probe
e-type
Flying Probe
DKS
Drilling tolerances
Feinraster
When machining the assembly holes in the probe plate INGUN has avoided including any diagrams and tables of
(KTP) it is necessary to differ between the diameter of the tests carried out under laboratory conditions, because such
drilled hole and the diameter of the actual drill. The sizes results would only give the user a false impression. This
stated in the catalogue refer to the diameter of the drilled being because the previously stated influences are non-cal-
Metr. Stand.
hole. This size can be measured with a standard plug gauge. culable factors, which can have a decisive influence on the
GKS
Depending on the material and the thickness of the probe- life-expectancy of a test probe. Under laboratory conditions
plate, the diameter of the drill should be 0.01– 0.03 mm it is possible for some test probes series to achieve well over
larger. At the same time, other parameters such as drill speed 1 million cycles, but the actual period of usage could well
Kurz/Lang
and feed, and so on, also play an important role. Note: it is be much less because, for example, the strong general wear
HSS
vital to carry out drilling tests before the final drilling of the of the test probe leads especially to wear of the contacting
probe plate. zone-resulting in a drastic increase of the contact resistance
values.
Dipol/Vierpol
The materials FR4/G10 (fibreglass enforced synthetic ma-
Robust
terial) and CEM1/Trolitax (hard-paper impregnated with
resin) have proven to be especially suitable as probe-plate Application temperature range
materials. Especially in the case of small assembly hole
diameters,there is an acute danger of the drilled holes slan- INGUN test probes can be used without any problems be-
ting, which leads to both receptacles and test probes also tween -40°C and +80°C. For lower and higher temperature
SKS
being slanted when inserted, and subsequently impairs the ranges there are many solutions available see “Application
contacting accuracy. In this case, INGUN recommends that Temperature Range” by the various probe series.
the assembly holes in probe plates thicker than > 10 mm are
counter-bored from the underside. Furthermore, drilling the These test probes are normally recognisable with the special
GKS ... M
holes in stages is also advisable. designation “C” (-100°C to +200°C). Certain high-alloyed
(stainless steel) spring steel types are used, which however
have the disadvantage that the transition resistance is up to
Verdreges. GKS
Life expectancy of INGUN test probes factor 10 higher as by standard test probes. Apart from this,
the stability of the resistance is affected (i.e. fluctuations are
VF
To determine the life expectancy of test probes, INGUN possible).
continuously carries out lifecycle tests under laboratory con-
ditions using computer-controlled fully automatic lifecycle In the case of these solutions there is also the danger that
HF-Kontaktstifte
Diplo-GKS
recommended working stroke, axial loading, current loading, This may cause the temperature to exceed the recommen-
GKS
as well as external influences such as contamination and ded operating temperature range and result in damage to
temperature. the test device or test probes.
Zubehör
Werkzeug
17
Technical Information
The choice of the base materials is dependent on the Hard gold, chemical nickel, and rhodium are used to plate test
performance demanded of each individual component. probes, depending on which functional features are required
Brass is sometimes used for passive tip styles and for Hard gold provides the best chemical resistance, has a hard-
machined barrels. The high percentage of copper makes it ness range of 150 - 200 HV, and is especially good against
an ideal electrical conductor. Brass, however, is too soft for oxidation.
aggressive tip styles. Rhodium is extremely resistant to abrasion, has a hardness
Steel is used for practically all aggressive tip styles, and pro- range of 600 - 1000 HV, but it is very brittle. Therefore, this
vides a high degree of hardness and sharpness of the points plating material is not suitable for aggressive tip styles in
and the flanks. This ensures good durability and conjunction with high spring forces. Rhodium is used when
reliable contacting. plunger tips are required to be especially durable.
BeCu (Beryllium Copper) provides a good combination Chemical nickel offers very good chemical resistance, and
and compromise between brass and steel: The high percen- has a hardness range of 400 - 600 HV, which prevents
tage of copper makes it an ideal electrical conductor and the contamination build up on points and edges (the so-called
small percentage of beryllium allows the base material to be “dog-bone” effect). Thus, it makes an excellent durable
hardened (up to 435 HV). This ensures good durability and layer for plungers and is ideal for aggressive tip styles.
optimises the aggressiveness of the plunger tip. Aurun is a gold-alloy plating material which was developed
Nickel silver (NiAg) and bronze are mainly used for recepta- especially for test probes, has very good chemical resistance
cles and the barrels of the test probes. These materials have and a hardness range of 300 - 350 HV. It is used for aggres-
a high tensile strength, which is ideal for the long-term life sive tip styles to test unwashed PC boards.
of test probes. Furthermore, these materials provide elasticity
to the crimps on the receptacles. All plating materials guarantee the best contacting reliability
Spring steel of the highest possible quality is used for the due to their very low, specific resistance values.
manufacturing of the springs. For high and low temperature
ranges, certain high-alloyed spring steels (i.e. stainless steel)
are used.
EG Environmental Legislation
Numerous European Environmental Legislation Acts aim
INGUN REACH RoHS
to ensure a high level of protection of human health and Environment ACPEIP
EU ordinance EU directive
the environment. This legislation is always observed as Compliance
Statement 1907/2006 2011/65/EU
“China-RoHS”
part of the business decisions and actions taken by INGUN
Prüfmittelbau GmbH. Conflict BIOCIDE CLP DMF
Minerals EU directive
EU/528/2012 EG/1272/2008
2009/251/EC
INGUN has prepared official statements for the most impor- Dodd-Frank Act
18
Information
Product
Technical Information
FAQ
Standard
GKS
Frequently Asked Questions
Bead Probe
e-type
Flying Probe
DKS
The term grid describes the distance between two test points on a PCB/DUT, the
Feinraster
distance between two component pins or connectors. Based on the test probe,
the distance is defined as the middle of one mounting hole to the middle of the
next mounting hole on the probe plate. There are internationally recognised grid
distances which manufacturers of PCBs and connectors observe. Because the
Metr. Stand.
definition is based on imperial units rather than metric units, the grid size is given
GKS
in inches. Because the gird size are sometimes very small, the grid dimension
What is a grid?
1/1000 inch is used. 1/1000 inch is also denoted as Mil.
Kurz/Lang
HSS
40 Mil = 1.0 mm
50 Mil = 1.27 mm
75 Mil = 1.91 mm
100 Mil = 2.54 mm
Dipol/Vierpol
Robust
No. As a rule of thumb, the spring force should simultaneously be as low as possible
in order to minimise the stress placed on the device under test (DUT), but also as
Does a high spring force ensure
high as necessary to guarantee a reliable electrical contact. Furthermore, other
reliable contact?
criteria, such as tip style, test environment, etc. must be taken into consideration
SKS
in order to select the correct spring force.
GKS ... M
receptacles are pressed into the assembly borehole up to the collar, which acts
as a stopper to achieve a defined installation height. The press-ring receptacles
What is the difference between can also be installed using the press-ring as a stopper, but with the press-ring
receptacles with press-ring and countersunk in the borehole making the installation height adjustable. The main
Verdreges. GKS
receptacles with a collar? difference between receptacles with and without a press-ring is the production
VF
process. Barrels with press-rings are deep drawn and have a compressed collar,
which has elastic properties. Receptacles without press-rings are produced using
traditional turning methods to hollow out solid material, which means the collar HF-Kontaktstifte
Threaded test probe have the special designation “M” and are screwed into
the receptacle rather than pressed in. These type of receptacles are used in
When should threaded test probes
particularly challenging test conditions, such as installation in a test set-up subject
be used?
Pneum.
in the receptacle.
Knurled receptacles are used especially for assembly boreholes with higher than
Vielseitige
specified tolerances or when non-rotating test probes are used, as they minimise
Why do some receptacles have a
GKS
19
Technical Information
During in-circuit tests (ICT) all components on the PCB are In order to optimally fulfill the contacting requirements, va-
measured. In doing so, defective components are detected rious test probes are available. These differ in terms of instal-
and can be replaced accordingly. lation height, grid size (possible distance between probes),
Function tests (FCT) check the entire intended function of tip style, and type of connection – see following illustration.
a PCB. According to the intended area of use, the environ- The electrical connection is achieved either with a solder cup
ment is replicated and the electrical performance of the PCB or wire-wrap, with or without cable (wireless).
is checked.
FCT
ICT
20
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
ICT/FCT Test Probes
Standard Stroke 24 - 29
Depending on the PCB to be contacted, and the ambient
conditions, INGUN offers a variety of test probes:
Fine Pitch
Long Stroke 30 - 32
Stand. GKS
test fixtures to combine ICT and FCT. Test Probes (GKS) 34 - 40
Metric
Wireless receptacles enable the wireless connection of test
probes using a transfer PCB. INGUN E-TYPE® 42 - 43
Rotating
short / long
Short / robust test probes stand out due to their robust,
Test Probes (DKS) 44 - 46
HSS
compact design.
Bead Probes 48
INGUN E-TYPE® test probes have a higher preload in com-
parison to standard test probes. This initial higher spring force Flying Probes 49
Robust HSS
Dipole HSS
guarantees a secure contact at the same final load (the spring
force is equal to that of the comparable standard test probe at Fine Pitch 52 - 57
working stroke).
Metric Standard 61 - 72
Rotating test probes can provide a reliable alternative if
SKS
contacting problems occur. A rotating movement during the
stroke process scratches the surface to be contacted, thus
insulating layers are securely penetrated.
Step Probes
GKS ... M
Bead test probes are used to contact beads on PCBs.
A variety of tip styles are available depending on the beads.
Fine pitch test probes are used to contact very small test
rotating GKS
VF / Non-
points in small grids. These are sometimes mounted without
receptacles.
Note:
See next page for overview
and comparison table.
Tools
21
21
Technical Information
ICT- FCT
Overview and Comparison of Test Probes
Installation heights
Grid Working Max. Spring forces Shortest
Current with receptacles
Test probe version Series size stroke stroke (N) probe Page
rating (A) (mm) v = variable
(≥ mm) (mm) (mm) (mm)
min max min max v
GKS-040 1 4.3 6.35 2 0.8 - 16 18 v 35.9 24
GKS-050 1.27 4.3 6.35 2–3 1 2 16 18 v 43.2 25
Standard stroke
GKS-075 1.91 4.3 6.35 3–4 0.6 2.8 10.5 23 v 33.1 26
GKS-100 2.54 4.3 6.35 5–8 0.6 4 10.5 25.5 v 33.4 28
GKS-015 1.27 8 10 2–3 1 1.5 21.3 23.3 v 48.5 30
Long stroke GKS-035 1.91 8 10 3–4 1.2 - 14.2 23.7 v 36.8 31
GKS-135 2.54 9.3 11.5 5–8 1.5 3 15.8 21.3 v 38.7 32
KS-040 WL 1 2.5 4 2–3 1 - - 16 v 43.4 33
KS-550 WL 1.27 2.5 4 2–3 1 - - 16 v 43.1 33
Wireless receptacles
KS-075 WL 1.91 2.5 4 2–3 1 - - 16 v 43.1 33
KS-100 WL 2.54 2.5 4 2–3 1 - - 16 v 43.1 33
GKS-550 1.27 4.3 6.35 2–3 1 1.5 - 16 v 34.6 34
GKS-101 1.91 4 5.3 3–4 0.5 1.5 12.5 14 - 27.3 35
GKS-001 1.91 2.4 3 3–4 0.6 1.5 - 8.5 v 17 36
Short / robust test
GKS-002 2.54 2.7 4.1 5–8 1 2.8 - 12.1 v 24.6 37
probes (GKS)
GKS-003 3.18 4.4 6.35 5–8 1.2 3 - 16 v 33.1 38
GKS-004 4.75 4.4 6.35 6–8 1.5 3 - 16.5 v 33.6 39
GKS-005 4.75 4.4 6.35 6–8 2 5 - 16.5 v 27.2 40
E-050 1.27 4.3 6.35 2–3 2 - 16 18 v 43.2 42
E-075 1.91 4.3 6.35 3–4 2 2.8 10.5 20 v 33.1 42
INGUN E-TYPE®
E-100 2.54 4.3 6.35 5–8 2 3 10.5 25.5 v 33.4 43
E-422 2.54 6.4 8 5–8 2.25 3 16.2 24 v 38.4 43
DKS-050 1.27 4.3 6.35 2–3 1.5 2 16 18 v 43.2 44
DKS-075 1.91 4.3 6.35 3–4 1 2 10.5 20 v 33.1 44
Rotating test probe
DKS-100 2.54 4.3 6.35 5–8 1 3 10.5 25.5 v 33.4 44
(DKS)
GKS-725 2.54 4 5 3–4 1.5 - 13.0 16.0 - 30 45
GKS-713 4.5 4 5 5–8 1.5 5 13.2 18.2 - 40 46
GKS-050 1.27 4.3 6.35 2–3 1 2 16 18 v 43.2 48
GKS-075 1.91 4.3 6.35 3–4 0.6 2.8 10.5 23 v 33.1 48
Bead probes GKS-100 2.54 4.3 6.35 5–8 0.6 4 10.5 25.5 v 33.4 48
GKS-135 2.54 9.3 11.5 5–8 1.5 3 15.8 21.3 v 38.7 48
GKS-550 1.27 4.3 6.35 2–3 1 1.5 - 16 v 34.6 48
Flying probe GKS-112 MD 2.54 4 5.3 / 8 5–8 0.6 3 14.7 21.6 - 40 49
GKS-038 0.635 2 2.5 1 0.4 - 4 - - 24 52
GKS-061 0.8 2.5 3.5 2 0.6 - 5.5 - - 36.2 52
GKS-080 1 3 3.8 3 0.8 - 10.5 - - 19.3 53
Fine pitch GKS-081 1 5.5 7.5 3 0.8 - 10.5 16 - 34.6 54
GKS-069 1.27 2.2 2.8 3 0.7 1 6.3 6.7 v 16.5 55
GKS-079 1.27 1 1.2 3 1.3 - 3.2 - - 14.5 56
GKS-181 1.27 5.5 7.5 2–3 0.8 1.5 10.5 16 - 34.9 57
GKS-112 2.54 4 5.3 / 8 5–8 0.6 5 26.3 32.3 v 40.3 61
GKS-912 2.54 4 5 5–8 0.6 5 10.2 26 v 32 62
GKS-422 2.54 6.4 8 5–8 0.8 5 16.2 24 v 38.4 63
GKS-412 2.54 8 9.8 5–8 0.6 5 15 30.8 v 37.8 64
GKS-204 2.54 8 10 5–8 0.8 3 16.2 23.2 - 47.9 65
GKS-102 2.54 4.8 6.5 5–8 1.5 5 12.75 13.75 - 42.5 66
Metric standard
GKS-502 2.54 5.6 7 5 – 15 0.8 5 12.2 13.2 - 39.1 67
GKS-113 4 4 5.3 5–8 0.3 5 10.5 18.5 - 27.3 68
GKS-913 4 2.8 3.5 5–8 0.8 2.5 7.3 9.0 - 15.1 69
GKS-103 4 4.8 6 5–8 0.8 5 12.55 - - 29.3 70
GKS-503 4 5.6 7 5 – 15 1.5 5 13.25 - - 38 71
GKS-854 5.08 4.4 5.5 10 – 12 3 5 10.8 - - 38.5 72
22
Information
Product
Contents
Technical Information
Standard
GKS
(GKS without Collar)
E-TYPE
DKS
Flying Probe
Bead Probe
Standard Stroke
Fine Pitch
GKS-075 26
Depending on the working stroke of the test fixture, or the GKS-100 28
component or test points to be tested, various installation
heights are necessary. These can be achieved by a choice Long Stroke
of combinations of test probes and receptacles. Thus, the
Stand. GKS
optimal working stroke with nominal spring force can be GKS-015 30
Metric
achieved. GKS-035 31
GKS-135 32
Scale
Test 1:1 (mm)
probes come in standard, LH/LP (+ 2.0 mm), and
Wireless Receptacles
short / long
E (+ 5.0 mm) versions, as well as receptacles with various
HSS
collar heights. KS-040 WL 33
100 KS-550 WL 33
Long stroke test probes are used for combined ICT/FCT test KS-075 WL 33
in dual-stage test fixtures. KS-100 WL 33
Robust HSS
Dipole HSS
90
Wireless receptacles are used to transmit signals over a Short/Robust
80 spring-loaded plunger on a transfer PCB. Thus, a cable is Test Probes (GKS)
not required.
GKS-550 34
70 GKS-101 35
SKS
Short / robust test probes stand out due to their robust, GKS-001 36
compact design. This makes them suitable for harsh ICT/ GKS-002 37
60
FCT applications with limited space available, as well as in GKS-003 38
GKS-004 39
Step Probes
larger grid sizes.
GKS ... M
50 GKS-005 40
40
rotating GKS
VF / Non-
30
Scale 1:1 (mm)
20 RF Test Probes
Dipole-GKS
100
10
5
90
0
KS-040 WL
KS-550 WL
KS-075 WL
KS-100 WL
GKS-040
GKS-050
GKS-075
GKS-100
GKS-015
GKS-035
GKS-135
80
PKS
PSK
-10
70
-20
Assorted
GKS
60
-30
50
-40
Accessories
30
-60
Tools
23
20 23
-70
GKS 040 Grid:
≥ 1,00 mm
ICT-/FCT Test Probe ≥ 40 Mil
Installation height with KS: 16,0 / 18,0 mm (.630 / .709) / variable
Recommended stroke: 4,3 mm (.169)
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
GKS-040
ø 0,61 [.024] ø 0,4 [.016]
3 04 ∅ 0,40 A
GKS-040 (.016)
ø 0,61 [.024] ø 0,4 [.016]
6,9 [.272]
35,9 [1.413] 3 05 ∅ 0,40 A
GKS-040
ø 0,61 [.024] ø 0,4 [.016] (.016)
6,9 [.272]
GKS-040 ... LGKS-040
GKS-040 ... LP 35,9 [1.413] ø 0,61 [.024] ø 0,4 [.016] 22
2 ∅ 0,32 A
8,9
(Long version with longer plunger. See “available tip 6,9 [.350]
styles“.) *
[.272] (.013)
GKS-040 ... L GKS-040 37,9 [1.492]
35,9 [1.413]
6,9[.350]
8,9 [.272] 2 38 ∅ 0,40 A
35,9 [1.413] (.016)
ø 0,51 [.020]
GKS-040 ... L ø 0,77 [.030] 37,9 [1.492]
ø 0,82 [.032]
8,9 [.350]
2 97 ∅ 0,40 A
GKS-040 ...øL0,77 [.030]
ø 0,51 [.020] ø 0,82 KS-040 E08
37,9[.032]
[1.492] (.016)
KS-040 E08
7,9 [.311] 8,9 [.350]
33 [1.299] * conical down to ∅ 0,40 mm (.016)
ø 0,51 [.020] ø 0,77 [.030] 37,9 [1.492]
KS-040
ø 0,82 E08
[.032]
7,9 [.311]
ø 0,51 [.020]
33 [1.299] ø 0,77 [.030] ø 0,82 [.032]
KS-040 E08 KS-040
V-30 E08
Available tip styles
7,9 [.311] special version GKS-040...LP
KS-040 E08
Material
33 [1.299] Further versions
Plating
KS-040 E08 V-30
7,9 [.311] Tip style
∅ ∅ (inch)
33 [1.299]
KS-040 E08 V-30 KS-040 E08 V-30
2 97 ∅ 0,40 A
(.016)
KS-040 E08 V-30
Total length 37,9 mm (1.492), special designation"LP"
16 (.630)
18 (.709)
Note:
Electrical Data Operating temperature The receptacle KS-040 is available pre-
Current rating: 2 A Standard: -40° up to +80° C wired with 1 m AWG 30 wire (see
Ri typical: < 20 mW ordering example). Minimal recom-
mended bending radius: 10 mm (.394).
Mounting hole size
in CEM1 und FR4: ∅ 0,79-0,80 mm
(.0311-.0315)
Receptacles: K S – 0 4 0 E 0 8 K S – 0 4 0 E 0 8 V-3 0
Information
Grid:
Product
≥ 1,27 mm
≥ 50 Mil ICT-/FCT Test Probe
Installation height with KS: 16,0 / 18,0 mm (.630 / .709) / variable
Recommended stroke: 4,3 mm (.169)
Standard
GKS
Mounting and functional dimensions Available tip styles
version GKS-050
Material
Further versions
Plating
ø 0,78 [.031] ø 0,5 [.020] ø s. tbl. Tip style
∅ ∅ (inch)
ø 0,78 [.031] ø 0,5 [.020] ø s. tbl.
E-TYPE
GKS-050
DKS
ø 0,78 [.031] ø 0,5 [.020] ø s. tbl.
6,4 [.252] 0,5 [.020] 2 01 ∅ 0,50 A
GKS-050 (.020)
GKS-050 43,2 [1.701] 6,4 [.252] 0,5 [.020]
GKS-050 ... LP 43,2 [1.701] 6,4 [.252] 0,5 [.020]
3 02 ∅ 0,60 A
GKS-050
(Long ... L with longer plunger. See “available
version 43,2 [1.701]
tip styles“.) (.024)
Flying Probe
Bead Probe
8,9 [.350]
GKS-050 ... L
GKS-050 ... L 45,2 [1.780] 8,9 [.350] 3 03 ∅ 0,50 A 0,90 (.035)
8,9 [.350] (.020)
ø 0,54 [.021] ø 0,95 [.037] ø 45,2
1,05 [1.780]
[.041]
45,2 [1.780]
ø 0,54 [.021] ø 0,95 [.037] ø 1,05 [.041] 3 05 ∅ 0,50 A
KS-050 E08
ø 0,54 [.021] ø 0,95 [.037] ø 1,05 [.041] (.020)
7,9 [.311]
KS-050 E08
Fine Pitch
40,6 [1.598] 7,9 [.311] KS-050 E08 3 06 ∅ 0,90 A
40,6 [1.598] 7,9 [.311] (.035)
40,6 [1.598] KS-050 30 E08
0,3 [.012] KS-050 30 E08 3 07 ∅ 0,50 A 0,90 (.035)
KS-050 30 E08 (.020)
0,3 [.012]
Stand. GKS
KS-050 47 E08
0,3 [.012]
Metric
8,7 [.343] 2 14 ∅ 0,50 A
KS-050 47 E08 (.020)
8,7 [.343] 49,3 [1.941] KS-050 47 E08
8,7 [.343] 49,3 [1.941] 19
KS-050 E08 V-30 3 ∅ 0,90
49,3 [1.941] *
(.035)
KS-050 E08 V-30
short / long
KS-050
KS-050 35
E08E08
V-30 22
HSS
2 ** ∅ 0,40 A
KS-050 35 E08 (.016)
ø 0,5 [.020] ø 1,2 [.047] ø 0,89 [.035]
KS-050 35 E08
insulated
ø 0,5 [.020] ø 1,2 [.047] ø 0,89 [.035]
SE-050 for usage 2 31 ∅ 0,50 A
ø 0,5 [.020] insulated
ø 1,2 [.047] ø 0,89 [.035]
with KS-050 35 E08 (.020)
12 [.472]
insulated SE-050 for usage
Robust HSS
with KS-050 35 E08
Dipole HSS
SE-050 for usage
12 [.472] SE-050 V-30 35
forE08
usage 2 38 ∅ 0,50 A
with KS-050
12 [.472] with KS-050 35 E08 (.020)
SE-050 V-30 for usage
with KS-050
SE-050 V-30 35
forE08
usage
with KS-050 35 E08 2 77 ∅ 0,50 A
(.020)
21,3 (.839)
18 (.709)
16 (.630)
(.311)
2 91 ∅ 0,50 A
SKS
variable
(.020)
7,9
∅ 0,50
Collar height and installation height 2 97 (.020)
A
To adjust the installation height, recepta-
cles with a press-ring are used. The recep- * 0,3 mm longer than standard
Step Probes
GKS ... M
** conical down to ∅ 0,50 mm
tacles can be inserted up to the press-ring
(i.e. acting as a collar-stop) or with the
GKS-015 GKS-050...LP
GKS-050 ...L GKS-050...
GKS-050 ...
Available tip styles
press-ring pressed into the mounting hole. (mit
(withKS-050...)
KS-050...) special version GKS-050...LP
Material
Further versions
Plating
rotating GKS
∅ ∅ (inch)
VF / Non-
Working stroke: 4,3 mm (.169) Plunger: BeCu or steel, gold-plated
Maximum stroke: 6,35 mm (.250) Barrel: Bronze, gold-plated ∅ 0,50 A
2 91
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated (.020)
Alternative: 1,0 N (3.6oz); 2,0 N (7.2oz) or stainless steel*** (C)
Receptacle: BeCu, gold-plated Total length 45,2 mm (1.783), special designation"LP" RF Test Probes
Dipole-GKS
3 = BeCu
GKS
Material
Further versions
Plating
GKS-075 Tip style
∅ ∅ (inch)
Ø1,02 (.040) Ø0,64 (.0252)
ø0,8
0 06* A
0,8 ∅ 1,30
6,4 1,3 (.051)
(.252) (.051)
33,1(1.303)
2 01 ∅ 0,64 A
(.025)
GKS-075 … LH 3 02 ∅ 0,90 A
(.035)
(Long version with longer barrel.)
3 03 ∅ 1,20 A
7,7 (.047)
3 05 ∅ 0,64 A
9,7 (.025)
L-Version: by „tip style“ 35,1
291 (1.382)
064 ... longer plungers(.382)
are used,
by all other tip styles longer barrels are used.
3 06 ∅ 1,00 A 1,20 (.047)
(.039)
L-Version:
GKS-075 … byE „tip style“ 291 064 ... longer plungers are used,
by all other tip styles longer barrels are used. 2 07 ∅ 0,64 A
(.025)
7,7
2 07 ∅ 1,00 A 1,20 (.047)
38,1 (1.500) (.303) (.039)
2 09 ∅ 0,64 A
(.025)
3 13 ∅ 0,61 A
(.024)
2 14 ∅ 0,50 A
(.020)
2 14 ∅ 0,64 A
(.025)
ø0,8
ø1
2 17 ∅ 1,20 A
(.047)
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil ICT-/FCT Test Probe
Installation height with KS: 10,5 - 23,0 mm (.413 - .906) / variable
Recommended stroke: 4,3 mm (.169)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Ø 1,32 (.052) Ø 1,47 (.058) Tip style
∅ ∅ (inch)
KS-075 30 G
E-TYPE
7,6 (.300)
DKS
30 (1.181) 3 19 ∅ 1,20 A 1,50 (.059)
(.047)
KS-075 30 E03
24 ∅ 1,30 A
2 (.079) 2 ***
30 (1.181) (.051)
Flying Probe
Bead Probe
KS-075 30 E05 2 25 ∅ 1,20 A 1,30 (.051)
(.047)
2 (.079)
30 (1.181)
2 31 ∅ 0,64 A
Ø 0,91(.036) (.025)
KS-075 35 G
Fine Pitch
0,64 (.025) 7,6 (.300) 2 38 ∅ 0,64 A
(.025)
KS-075 47 G ø1,2
ø1
10 (.394)
40,0 (1.575)
3 55 A
Stand. GKS
2,54
KS-075 47 E03 3,7 ∅ 0,50
Metric
2 (.079) Total length plus 2,4 mm (.020)
40,0 (1.575)
2 77 ∅ 0,64 A
KS-075 47 E05 (.025)
2 (.079)
40,0 (1.575)
2 88 ∅ 1,20 A
short / long
(.047)
HSS
KS-075 47 G 10
10
ø1,15
2 89 ∅ 0,50 A
Ø 0,63 (.025) (.394)
(.020)
KS-075 44 G
10 (.394) 7,6 (.300) 2 91 ∅ 0,64 A
Robust HSS
Dipole HSS
40,0 (1.575) (.025)
2 97 ∅ 0,64 A
(.025)
10,5 / 13 (.413/512)
2 97 ∅ 0,80 A
(.031)
18 (.709)
SKS
16 (.630)
7,6 (.300)
2 98 ∅ 0,64 A
variable
(.025)
Step Probes
To adjust the installation height, recep-ta-
GKS ... M
cles with a press-ring are used. The recepta- Available tip styles
cles can be inserted up to the press-ring (i.e. special version GKS-075...LP
acting as a collar-stop) or with the press-ring
Material
Further versions
Plating
rotating GKS
VF / Non-
(with KS-075...G) (withKS-075...G) (withKS-075
example“ on this page). 47 E03/E05) ∅ 0,64 A
2 91
(.025)
KS-075 ... E05 13,0 mm (.512) / var. 15,0 mm (.591) / var. 18,0 mm (.709)
KS-075 ... G 16,0 mm (.630) / var. 18,0 mm (.709) / var. 21,0 mm (.827)
KS-075 ... G 10 18,0 mm (.709) / var. 20,0 mm (.787) / var. 23,0 mm (.906)
Ordering example
Receptacles with wire-wrap posts: KS–075 47 E03 KS–075 47 E05 K S – 0 7 5 4 7 G
Accessories
Receptacles: K S – 0 7 5 3 0 G K S – 0 7 5 3 5 G
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
GKS-100
Ø1,37 Ø0,9
ø1,8
øs. tbl.
(.054) (.035) 0 06* A
∅ 2,25
0,9
100 (.089)
Ø1,37 25 (.984) 6,4
Ø0,9 2 (.079)
øs. tbl.
ø2,0
(.054) (.252)
(.035)
33,4 (1.315) 0 06*
100 0,5 ∅ 3,23
Ø1,37 Ø0,9 (.127)
-100 ... L Ø1,37 25 (.984) 6,4
Ø0,9 2øs. tbl.
(.079)
(.054) (.035) øs. tbl.
GKS-100 … LH
(.054) (.252)
(.035)
100 2733,4 (1.315)
(1.063) 2 01 ∅ 0,90 A
100 (Long version with longer barrel.)
(.035)
25 (.984)
35,4 (1.394) 6,4 2 (.079)
25 (.984) 6,4
(.252) 2 (.079)
100 ... L 33,4 (1.315) (.252) 3 02 ∅ 1,50 A 0,90 (.035)
-100 ... L 27 33,4 (1.315)
(1.063)
(.059)
25 (.984)
35,4 (1.394) 10,4(.409)
100 ... L
100 ... L 27 35,4 (1.394)
(1.063) 3 03 ∅ 1,50 A
27 (1.063) (.059)
100 ... L
rsion: by „tip style“ 291… 090
GKS-100 LP ... and 307 090
35,4 ... longer
(1.394)
ø1,2 ø1,06
are 10,4
25 (.984)
35,4 (1.394) (.409)
gers are used, by (Long other tip
all version withstyles longer
longer barrels
plunger. used.tip styles“.)
See “available
35,4 (1.394) 2 04 ∅ 1,06 A
100 ... L (.042)
100 ... L
sion:...by
-100 E „tip style“ 291 090 ... and 307 090 ... longer 10,4(.409)
25 (.984)
25 (.984) 10,4(.409)
gers are used, by all other tip styles longer
30 (1.181) barrels are used.
35,4 (1.394)
35,4 (1.394) 2 04 ∅ 1,30 A 1,50 (.059)
sion: by „tip style“ 291 090 ... and 30738,4
(1.512) (.051)
090 ... longer
sion:
100 ...
gers by
are „tip style“
E used, by all291 090
other tip...styles
and 307 090barrels
longer ... longer
are used. (.020)
0,50
gers are used, by all other
GKS-100 … Etip styles longer barrels are used.
30 (1.181) 3 05 ∅ 0,90 A 0,64 (.025)
(.035) 1,30 (.051)
100 ... E 38,4 (1.512)
1,50 (.059)
100 ... E
30 (1.181) 3 06 ∅ 1,30 A
2,00 (.079)
30 (1.181) (.051)
2,50 (.098)
38,4 (1.512) 3,00 (.118)
38,4 (1.512)
3 07 ∅ 0,90 A
(.035)
3 13 ∅ 0,90 A
Wire-wrap Solder Cap GKS-100 GKS-100 ... LH/LP GKS-100 ... E (.035)
KS-100 30 G
KS-100 47 G 16,0 (.630)/var. 18,0 (.709)/var. 21,0 (.827)/var. 2 14 ∅ 1,30 A 1,50 (.059)
KS-100 44 G **** (.051)
KS-100 47 G12 KS-100 30 G12 20,5 (.807)/var. 22,5 (.886)/var. 25,5 (.1004)/var.
3 14 ∅ 1,30 A
**** KS (receptacle) with round post to solder (.051)
Ri typical: < 20 mW (*** < 100 mW) into the mounting hole:
in CEM1: ∅ 1,71 - 1,73 mm (.0673 - .0681) 2 31 ∅ 0,90 A
(.035)
in FR4: ∅ 1,70 - 1,72 mm (.0669 - .0677)
2 33 ∅ 1,06 A
Operating temperature For KS-100 with collar or press-ring as a (.042)
Standard: -40° up to +80° C collar-stop:
***with special designation "C": CEM1 and FR4: ∅ 1,67 - 1,69 mm * 0,9 mm or 0,5 mm longer than Standard
-100° up to +200°C (1,5 N; 2,0 N; 3,0 N) (.0657 - .0665) ** higher middle tip, plus 0,4 mm
C-versions only available for GKS-100 with
total length 33,4 mm (1.315).
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil ICT-/FCT Test Probe
Installation height with KS: 10,5 - 25,5 mm (.413 - 1.004)
Recommended stroke: 4,3 mm (.169)
Standard
GKS
Available tip styles
Receptacles with collar
Material
Further versions
Plating
Ø1,67
Ø
Ø 1,67 Ø
ØØ1,8
1,8 Tip style
(.066)
(.066)
(.066) (.071)
(.071)
(.071) ∅ ∅ (inch)
With
KS-100
KS-100 30
30
wire-wrap posts (vacuum-sealed) With solder connection
E-TYPE
DKS
5,5
5,5 (.217)
(.217)
(.217)
0,6 (.024) ø1,67
32 (1.260)
32 (1.260) ø1,8 ø1,67 ø1,8 2 38 ∅ 0,90 A
(1.260) (.035)
(.066) (.071) (.066) (.071)
KS-100
KS-10047
KS-100 47
47 ø1,42
ø1,02
9,3
(.366)
(.366)
(.366) 9,3
9,3 5,5 KS-100 30
5,5 (.217)
5,5 (.217)
(.217) 5,5
(.366) 36,8
36,8(1.449)
36,8 (1.449)
(1.449)
(1.449) (.217) 32 (1.260) (.217) 3 55 A
Flying Probe
Bead Probe
KS-100
KS-100 47
47 40
40 2,54
44(.157)
(.157) KS-100 30 40 3,7
36,8(1.449)
36,8 (1.449)
(1.449)
(.157) 4 ∅ 0,64
26,9 (1.059) (.157) max. stroke: 4,7 mm (.185) (.025)
KS-100
KS-100 47
47 25
25 2,5(.098)
2,5 (.098) KS-100 30 25
(.098)
36,8 (1.449)
(1.449)
36,8 (1.449) 2,5 2 77 ∅ 0,90 A
26,9 (1.059) (.098) (.035)
Ø
Ø 1,67(.066)
Ø1,67 (.066)
(.066) Ø1,8
Ø
Ø 1,8 KS-100 30 05
Fine Pitch
(.071)
(.071)
(.071) 0,2 2 88 ∅ 1,50 A 1,90 (.070)
27,7 (1.091) (.008)
KS-100
KS-100 47
47 05
05 0,2
0,2 (.059)
37,9 (1.492)
37,9 (1.492)
(1.492) (.008)
(.008)
(.008)
KS-100 30 93*
0,2 2 89 ∅ 0,50 A
27,7 (1.091) (.008) (.020)
KS-100
KS-100 47
47 93*
93* 0,2
0,2
37,9(1.492)
37,9 (1.492)
(1.492) (.008)
(.008)
(.008)
Stand. GKS
2 91 ∅ 0,90 A
Metric
* for use with tip style 93 (.035)
short / long
2 93* A
∅ 1,60
HSS
7,6 (.300) (.063)
30 (1.181)
KS-100 30 G 12 2 97 ∅ 0,90 A
(.035)
12(.472)
30 (1.181)
0,64
Robust HSS
Dipole HSS
2 98 ∅ 0,90 A
(.025) (.035)
KS-100 47 G
10 (.394) 7,6 (.300) * 5 mm longer than standard tip styles
40 (1.575)
Available tip styles
KS-100 47 G 12 special version GKS-100...LP
12(.472)
40 (1.575)
Material
SKS
Further versions
Ø 0,63
Plating
Tip style
(.025) ∅ ∅ (inch)
KS-100 44 G
10 (.394) 7,6 (.300) ∅ 0,90 A
40 (1.575) 3 07
(.035)
Step Probes
GKS ... M
2 91 ∅ 0,90 A
(.035)
Example with GKS-100 (Total length GKS = 33,4 (1.315))
rotating GKS
Note to GKS-100 with tip style 93:
VF / Non-
16
20,5 (.630) 14,5 13
16 (.807) (.571) (.512)
10,5
(.413)
- Installation height with KS-100 30/47: 21,0 mm (.827)
(.630)
- Installation height with KS-100 47 93: 16,0 mm (.630)
INGUN recommend using tip style 93 in combination with the GKS-100 ...E
test probe series RF Test Probes
Dipole-GKS
Note:
KS-100 47 G12
KS-100 47 40
KS-100 47 25
KS-100 47 05
KS-100 47 G
Receptacles: K S – 1 0 0 3 0 G K S – 1 0 0 4 7 G
Tools
Material
Plating
versions
Tip styles
ø 0,78 [.031] ø 0,5 [.020] ∅ ∅ (inch)
GKS-015 3 07 ∅ 0,50 A
ø 0,78 [.031] ø 0,5 [.020]
12,2 [.480] (.020)
48,5 [1.909]
GKS-015 ø 0,78 [.031] ø 0,5 [.020] 2 91 ∅ 0,50 A
(.020)
GKS-015 ... LP 12,2 [.480]
GKS-015… LP
GKS-015 14,2 [.559]
48,5 [1.909]
(Long version with longer plunger. See “available tip styles“.) 12,2 [.480]
50,5 [1.988]
GKS-015 ... LP 48,5 [1.909]
ø 0,54 [.021] ø 0,95 [.037] ø 1,05 [.041] 14,2 [.559] Available tip styles
GKS-015 ... LP special version GKS-015...LP
50,5 [1.988] 14,2 [.559]
KS-050 E08
Material
Further versions
Plating
ø 0,54 [.021] ø 0,95 [.037] ø 1,05 [.041]
50,5 7,9 [.311 ]
[1.988] Tip style
∅ ∅ (inch)
40,6 [1.598]
ø 0,54 [.021] ø 0,95 [.037] ø 1,05 [.041] KS-050 E08
2 91 ∅ 0,50 A
7,9 [.311 ]
KS-050 E08 (.020)
40,6 [1.598] KS-050 30 E08
7,9 [.311 ]
40,6 [1.598]
0,3 [.012]
KS-050 30 E08
KS-050 30
KS-050 47 E08
E08
0,3 [.012]
8,7 [.343]
49,2 [1.937]
0,3 [.012]
21,3 [.839]
KS-050 47 E08
8,7 [.343] KS-050 47
E08E08
V-30
KS-050
49,2 [1.937]
8,7 [.343]
49,2 [1.937] KS-050 E08 V-30
KS-050 35 E08
KS-050 E08 V-30
ø 0,5 [.020] ø 1,2 [.047] ø 0,89 [.035]
insulated KS-050 35 E08
SE-050 for usage
with KS-050 35 E08
12 [.472]ø 0,89 [.035]
ø 1,2 [.047] KS-050 35 E08
ø 0,5 [.020]
insulated GKS-015
ø 0,5 [.020] ø 1,2 [.047] ø 0,89 [.035]
SE-050 for usage
V-30 for usage (with KS-050 ... E08)
insulated12 [.472] with KS-050 35 E08
SE-050 for usage
12 [.472] with KS-050 35 E08 Collar height and installation height
SE-050 V-30 for usage
with KS-050 35 E08 To adjust the installation height, recepta-
SE-050 V-30 for usage cles with a press-ring are used. The recep-
with KS-050 35 E08 tacles can be inserted up to the press-ring
(i.e. acting as a collar-stop) or with the
press-ring being pressed into the mounting
hole.
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil
Installation height with KS: 14,2 - 23,7 mm (.559/ .933) / variable
Recommended stroke: 8,0 mm (.315)
Standard
GKS
Mounting and functional dimensionsø 0,64 [.025]
ø 1,02 [.040] ø s. tbl. Available tip styles
ø
ø 1,02
1,02 [.040]
[.040] ø
ø 0,64
0,64 [.025]
[.025] ø
ø s.
s. tbl.
tbl.
Material
Further versions
Plating
GKS-035 Tip style
GKS-035
GKS-035 ∅ ∅ (inch)
10 [.394] 1,3 [.051]
10
10 [.394]
[.394] 1,3
1,3 [.051]
[.051]
E-TYPE
36,8 [1.449]
DKS
3 06 ∅ 1,15 A
36,8
36,8 [1.449]
[1.449] (.045)
GKS-035 … LH
(Long version with longer barrel.)
GKS-035 .... L 2 07 ∅ 1,15 A
GKS-035
GKS-035 ....
.... L
L (.045)
10,1 [.397] 1,3 [.051]
Flying Probe
Bead Probe
10,1
10,1 [.397]
[.397] 1,3
1,3 [.051]
[.051]
38,8 [1.528] 2 14 ∅ 1,15 A 0,64 (.025)
GKS-035 … LP 38,8
38,8 [1.528]
[1.528] (.045)
(Long version with longer plunger. See “available tip styles“.)
GKS-035 ... LP 2 91 ∅ 0,64 A
GKS-035
GKS-035 ...
... LP
LP 13,4 [.528] (.025)
13,4
13,4 [.528]
[.528]
38,8 [1.528]
Fine Pitch
38,8
38,8 [1.528]
[1.528] Available tip styles
special version GKS-035 ... LP
Material
Further versions
Plating
Ø 1,32 (.052) Ø 1,47 (.058) Tip style
∅ ∅ (inch)
KS-075 30 G
Stand. GKS
7,6 (.300)
Metric
30,2 (1.189) 2 91 ∅ 0,64 A
(.025)
KS-075 30 E03
2 (.079)
30 (1.181)
7,6 [.299]
7,6 [.299]
21,7 [.854]
19,7 [.776]
short / long
[.559 / .657]
KS-075 30 E05
14,2 / 16,7
variable
HSS
2 (.079)
30 (1.181)
Ø 0,91 (.036)
KS-075 35 G
Robust HSS
Dipole HSS
7,6 (.299)
Ø 0,63 (.025)
KS-075 44 G
40,0 (1.575)
GKS-035...LH/LP GKS-035 GKS-035
0,64 (.025) (with KS-075...G) (with KS-075...G) (with KS-075 47
SKS
E03/E05)
KS-075 47 G
9,8(.386) Collar height and installation height
40,0 (1.575)
To adjust the installation height receptacles with a press-ring are
KS-075 47 E03 used.
Step Probes
Designation GKS-035 GKS-035 ... LH/LP
GKS ... M
39,8 (1.567)
KS-075 ... E03 14,2 mm (.559) / var. 16,2 mm (.638) / var.
KS-075 47 E05
KS-075 ... E05 16,7 mm (.657) / var. 18,7 mm (.736) / var.
39,8 (1.567)
KS-075 ... G 19,7 mm (.776) / var. 21,7 mm (.854) / var.
rotating GKS
VF / Non-
KS-075 47 G 10 KS-075 ... G10 21,7 mm (.854) / var. 23,7 mm (.933) / var.
10
(.394)
Mechanical data Materials
Working stroke: 8,0 mm (.315) Plunger: BeCu or steel, gold-plated Note:
Maximum stroke: 10,0 mm (.394) Barrel: Nickel-silver or Bronze, gold-plated Receptacles in the KS-075 series are RF Test Probes
Dipole-GKS
Spring force at work. stroke: 1,2 N (4.3oz) Spring: Steel, gold-plated used for the GKS-035 test probes
Receptacles: Nickel-silver, gold-plated series.
Mounting hole size
Press-ring pressed in mounting hole: Electrical data Operating temperature
∅1,39-1,40 mm (.0547-.0551) Current rating: 3-4A Standard: -40° up to +80° C
Pressring as collar-stop: Ri typical: < 20 mW
in CEM1: ∅ 1,30-1,32 mm (.0512-.0520)
PKS
PSK
3 = BeCu
GKS
Receptacles: K S – 0 7 5 3 0 G K S - 0 7 5 3 5 G
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
3 02 ∅ 0,90 A
(.051)
11,7(.461) 2 (.079)
2 04 ∅ 1,30 A
(.051)
3 06 ∅ 1,30 A
(.051)
3 06 ∅ 1,50 A
(.059)
2 09* ∅ 0,50 N
(.020)
2 14 ∅ 0,50 A
(.020)
2 14 ∅ 1,30 A
(.051)
2 14 ∅ 1,50 A
(.059)
2 25 ∅ 1,30 A
(.051)
2 91 ∅ 0,90 A
Collar height and installation height (.035)
The installation height of the test probe is
21,3 (.839)
(.217)
5,5
Test probe: G K S 1 3 5 2 0 4 1 3 0 A 2 0 0 0
Receptacle: K S – 1 0 0 4 7
Information
Grid:
Product
≥ 1.00 / 1,27 / 1,91 / 2,54 mm
≥ 40 / 50 / 75 / 100 Mil Wireless Receptacles
Installation height with KS: 16,0 mm (.630) / variable Spring Loaded Receptacles
Recommended stroke: 2,5 mm (.098)
Standard
GKS
Mounting and functional dimensions Available tip styles
plunger in receptacle
Wireless receptacles
Material
Further versions
Plating
Tip style
Ø0,51 Ø0,77 Ø0,77 Ø0,82 ∅ ∅ (inch)
E-TYPE
(.020) (.030) (.030) (.032)
DKS
KS-040 WL
3 07 ∅ 0,51 A
4 (.157) 7,9 (.311) (.020)
43.4 (1.709)
Flying Probe
(.041)
Bead Probe
(.020) (.036) (.037)
KS-550 WL
4 (.157) 7,6 (.300)
43.1 (1.697)
Ø1,32 Ø1,47
(.052) (.058)
KS-075 WL
Fine Pitch
Ø1,67 Ø1,85
(.066) (.073)
KS-100 WL
Stand. GKS
Metric
KS-040 WL KS-550 WL KS-075 WL KS-100 WL
with with with with
GKS-040 GKS-550 GKS-075 GKS-100
short / long
HSS
16 (.630)
(.311)
(.300)
7,9
7,6
Robust HSS
Dipole HSS
Mounting hole Sizes
KS-040 WL
with use of press-ring or with use of press-
ring as a collar:
35,5 (1.398)
SKS
in CEM1: ∅ 0,79-0,80 mm (.0311-.0315)
Collar height and installation height in FR4: ∅ 0,79-0,80 mm (.0311-.0315)
To adjust the installation height, recep-
tacles with a press-ring are used. The KS-550 WL
re-ceptacles can be inserted up to the press- with use of press-ring or with use of press-
Step Probes
GKS ... M
ring (i.e. acting as a collar-stop) or with the ring as a collar:
press-ring being pressed into the mounting in CEM1: ∅ 0,96-0,98 mm (.0378 - .0386)
hole. in FR4: ∅ 0,97-0,99 mm (.0382 - .0390)
KS-075 WL
rotating GKS
Mechanical data Materials with use of press-ring in:
VF / Non-
Working stroke: 2,5 mm (.098) Plunger: BeCu, gold-plated CEM1/FR4: ∅1,36-1,40 mm (.0535-.0551)
Maximum stroke: 4,0 mm (.157) Ball: Steel, gold-plated with use of press-ring as a collar in:
Spring force at work.stroke: 1,0 N (3.6oz) Spring: Steel, gold-plated CEM1/FR4: ∅1,31-1,32 mm (.0516-.0520)
Pre-load: 0,6 N (2.2oz) Receptacle: Nickel-silver, gold-plated
Pre-load at KS-040 WL: 0,5 N (1,8oz) KS-100 WL
RF Test Probes
Dipole-GKS
Operating temperature
Recomm. guiding pin hole: with use of press-ring in:
Standard: -40° up to +80° C
KS-040: ∅ 0,81-0,85 mm CEM1/FR4: ∅1,70-1,75 mm (.0669-.0689)
(.032-.033) Electrical data with use of press-ring as a collar:
KS-050 / 075 / 100: ∅ 0,96-0,99 mm Current rating: 2-3A in CEM1: ∅ 1,68-1,69 mm (.0661-.0665)
(.038-.039) Ri typical: < 20 mW in FR4: ∅ 1,69-1,70 mm (.0665-.0669)
PKS
PSK
Receptacle for grid 1,00 mm (40 Mil): K S – 0 4 0 W L Test probes see GKS-040 page 24
Accessories
Receptacle for grid 1,27 mm (50 Mil): K S – 5 5 0 W L Test probes see GKS-550 page 34
Receptacle for grid 1,91 mm (75 Mil): K S – 0 7 5 W L Test probes see GKS-075 page 26/27
Receptacle for grid 2,54 mm (100 Mil): K S – 1 0 0 W L Test probes see GKS-100 page 28/29
Tools
Material
Plating
versions
Tip styles
∅ ∅ (inch)
ø 0,78 [.031] ø 0,5 [.02]
2 01 ∅ 0,50 A
GKS-550 (.020)
6,9 [.272]
34,6 [1.362] 3 02 ∅ 0,60 A
(.024)
KS-550 47 E08
2 14 ∅ 0,50 A
8,6 [.339] (.020)
40,2 [1.583]
22
2 ∅ 0,40 A
*
(.016)
KS-550 E08 V-30
2 31 ∅ 0,50 A
(.020)
KS-550 35 E08
2 38 ∅ 0,50 A
ø 0,5 [.020] ø 1,2 [.047] ø 0,89 [.035] (.020)
insulated
SE-050 for usage 2 77 ∅ 0,50 A
with KS-550 35 E08 (.020)
12
∅ 0,50
2 97 (.020)
A
Operating temperature
Standard: -40° up to +80° C
Test probe G K S 5 5 0 2 9 1 0 5 0 A 1 5 0 0
Plug: S E - 0 5 0 S E - 0 5 0 V-30
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil Test Probe
Installation height with KS: 12,5 / 14,0 mm (.492 / .551)
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
ø 1 [.039] ø 0,5 [.020] ø s. tbl.
∅ ∅ (inch)
E-TYPE
GKS-101
DKS
3 01 ∅ 0,50 A
5,3 [.209] 2 [.079] (.020)
27,3 [1.075]
3 02 ∅ 1,15 A 0,50 (.020)
(.045)
ø 1,32 [.052] ø 1,42 [.056]
Flying Probe
Bead Probe
3 03 ∅ 1,15 A 1,50 (.059)
KS-101 30 (.045)
0,2 [.008]
26 [1.024] 3 04 ∅ 1,15 A
(.045)
0,64 [.025] ø 1,32 [.052]
Fine Pitch
3 05 ∅ 1,15 A
(.045)
KS-101 47
6 [.236]
3 06 ∅ 1,15 A 1,50 (.059)
24 [.945] (.045)
Stand. GKS
ø 1,32 [.052]
Metric
3 07 ∅ 1,30 A
(.051)
KS-101 35
22 [.866] 3 08 ∅ 1,15 A
(.045)
ø 1,32 [.052]
short / long
ø 0,9 [.035] ø 1 [.039] 3 14 ∅ 1,30 A
HSS
(.051)
Robust HSS
Dipole HSS
3 51 A
∅ 0,50
2 mm (.079) shorter (.020)
** higher middle tip plus 0,5 mm
Collar height an installation height
Install. Height
SKS
ceptacle (KS).
Step Probes
GKS ... M
KS-101 xx or
KS-101 xx E13 14,0 mm (.551) KS-101 xx E13
rotating GKS
VF / Non-
Working stroke: 4,0 mm (.157) Plunger: BeCu or steel, gold-plated
Maximum stroke: 5,3 mm (.209) Barrel: Nickel-silver, gold-plated
Spring force at work. stroke: 0,8 N (2.9oz) Spring: Steel, gold-plated
Alternative: 0,5 N (1.8oz); 1,5 N (5.4oz) or stainless steel* (C)
Receptacle: Brass or Nickel-silver, RF Test Probes
Dipole-GKS
gold-plated
Electrical data Mounting hole size
Current rating: 3-4A in CEM1:∅ 1,29 - 1,31 mm (.0508 - .0516)
Ri typical: < 20 mW (* < 100 mW) in FR4: ∅ 1,30 - 1,32 mm (.0512 - .0520)
Operating temperature
Standard: -40° up to +80° C
PKS
PSK
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
Assorted
2 = Steel
3 = BeCu
Accessories
Test probe: G K S 1 0 1 3 0 1 0 5 0 A 0 8 0 0
Receptacles: K S - 1 0 1 4 7 K S - 1 0 1 3 5 K S - 1 0 1 3 0 E 1 3
Plug: S E - 1 0 1
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
Ø1 (.039) ø0,75 (.030)
2 01 ∅ 0,75 A
(.030)
4,7
17 (.669) (.185) 3 02 ∅ 1,50 A
(.059)
ø s.tbl.
3 03 ∅ 1,50 A
(.059)
4 (.157)
3 06 ∅ 1,00 A
17,5 (.689) (.039)
KS - 001 47 G 3 07 ∅ 1,50 A
(.059)
10 (.394) 4 (.157)
27,5 (1.083)
(.335)
8,5
Test probe: G K S 0 0 1 2 1 4 1 5 0 A 1 0 0 0
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil ICT-/FCT Test Probe
Installation height with KS: 12,1 mm (.476)/variable
Recommended stroke: 2,7 mm (.106)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
Ø 1,37 (.054) Ø 1,07 (.042)
E-TYPE
DKS
2 01 ∅ 1,07 A
(.042)
4,1 2 (.079)
24,6 (.970) (.161) 3 03 ∅ 1,91 A
(.075)
Flying Probe
Bead Probe
Ø 1,67 (.066) Ø 1,78 (.070)
2 04 ∅ 1,52 A
(.060)
KS - 002 30 G
3 05 ∅ 0,64 A
6,1 (.240)
1,8 (.025)
24,2 (.953)
Fine Pitch
2 06 ∅ 1,91 A
0,64 (.025) (.075)
2 07 ∅ 1,91 A
KS - 002 47 G (.075)
9,3 (.366) 6,1 (.240)
Stand. GKS
Metric
33,5 (1.319) 2 14 ∅ 1,91 A
(.075)
2 17 ∅ 1,91 A
(.075)
short / long
HSS
Robust HSS
Dipole HSS
SKS
(.476)
12,1
Step Probes
GKS ... M
used. The installation height can be adju-
sted by assembling the collar lower in the
GKS-002
mounting hole.
with KS
rotating GKS
VF / Non-
Mechanical data Materials
Working stroke: 2,7 mm (.106) Plunger: BeCu or steel, gold-plated
Maximum stroke: 4,1 mm (.161) Barrel: Nickel-silver or Bronze, gold-plated
Spring force at work. stroke: 1,0 N (3.6oz) Spring: Steel, gold-plated
Alternative: 1,8 N (6.5oz); 2,8 N (10.1oz) Receptacle: Nickel-silver, gold-plated
RF Test Probes
Dipole-GKS
Ordering example
GKS
Series Tip Tip style Tip diameter Plating Spring force Collar height
material (1/100 mm) A = Gold (dN) (mm)
2 = Steel
3 = BeCu
Accessories
Test probe: G K S 0 0 2 3 0 3 1 9 1 A 1 0 0 0
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
2 01 ∅ 1,27 A
Ø 2,03 Ø 1,27 Ø s. tbl. (.050)
(.080) (.050)
3 02 A
∅ 1,00
1 (.039)
6,4 (.250) 2,0
(.079) 3 02 ∅ 1,27 A
33,1 (1.303)
(.050)
3 03 ∅ 2,54 A
(.100)
Ø 2,36 Ø 2,49
(.093) (.098)
2 04 ∅ 2,54 A
(.100)
3 05 ∅ 1,70 A
(.067)
3 05 ∅ 2,54 A
(.100)
2 06 ∅ 2,54 A
(.100)
3 08 ∅ 2,54 A
(.100)
(.630)
16
Series Tip Tip style Tip Plating Spring force Collar height
Ordering example material diameter A = Gold (dN) (mm)
2 = Steel (1/100 mm)
3 = BeCu
Test probe: G K S 0 0 3 3 0 3 2 5 4 A 2 0 0 0
Information
Grid:
Product
≥ 4,75 mm
≥ 187 Mil ICT-/FCT Test Probe
Installation height with KS: 16,5 mm (.650)/variable
Recommended stroke: 4,4 mm (.173)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
2 01 ∅ 1,52 A
Ø 2,36 Ø 1,52 Ø s. tbl. (.060)
(.093) (.060)
3 02 ∅ 3,96 A
(.156)
Flying Probe
Bead Probe
6,4 (.252) 2,54
2 03 ∅ 3,96 A
33,6 (1.320) (.100) (.156)
2 04 ∅ 1,52 A
Ø 2,69 Ø 2,8
(.060)
(.106) (.110)
Fine Pitch
3 05 ∅ 1,52 A
(.060)
7,6 (.300) KS-004 30 G
30,5 (1.200) 2 06 ∅ 3,96 A
(.156)
Stand. GKS
Metric
3 08 ∅ 3,96 A
(.156)
short / long
HSS
Robust HSS
Dipole HSS
SKS
(.650)
16,5
Step Probes
GKS ... M
by assembling the collar lower in the moun-
ting hole. GKS-004
with KS
rotating GKS
VF / Non-
Working stroke: 4,4 mm (.173) Plunger: Steel, gold-plated
Maximum stroke: 6,35 mm (.250) Barrel: Nickel-silver or Bronze, gold-plated
Spring force at work. stroke: 2,0 N (7.2oz) Spring: Steel, gold-plated
Alternative: 1,5 N (5.4oz); 3,0 N (10.8oz) Receptacle: Nickel-silver, gold-plated RF Test Probes
Dipole-GKS
Series Tip Tip style Tip diameter Plating Spring force Collar height
Ordering example
GKS
Test probe: G K S 0 0 4 2 0 1 1 5 2 A 2 0 0 0
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
s. tbl. 2 01 ∅ 2,03 A
Ø 3,16 Ø 2,03 Ø
(.080)
(.124) (.080)
2 03 ∅ 3,96 A
(.156)
6,4 (.252) 2,54
36,1 (1.420) (.100)
2 06 ∅ 3,96 A
(.156)
Ø 3,56 Ø 3,66
(.140) (.144)
(.650)
16,5
Series Tip Tip style Tip Plating Spring force Collar height
Ordering example material diameter A = Gold (dN) (mm)
2 = Steel (1/100 mm)
Test probe: G K S 0 0 5 2 0 6 3 9 6 A 3 0 0 0
INGUN E-TYPE®
Standard
GKS
Rotating Test Probes
E-TYPE
DKS
Flying Probe
Bead Probe
INGUN E-TYPE®
INGUN E-TYPE® test probes enable the highest contact
security on the PCB/UUT without additional stress. When E-050 42
contacting on the test surface, up to a 100% higher spring E-075 42
Fine Pitch
force is available, which is achieved by the increased spring E-100 43
pre-load of the E-TYPE probes. During the working stroke, E-422 43
however, the E-TYPE probes have the same spring force as
standard test probes. The additional contact energy gained
ensures a contact area between the test probe and the PCB Rotating Test Probes DKS
Stand. GKS
Metric
which is up to 25% larger.
DKS-050 44
DKS-075 44
4,00
Spring force N
DKS-100 44
3,50 GKS-725 45
short / long
3,00 GKS-713 46
HSS
2,50 y
erg
2,00 l En
na
itio
1,50 A dd
Scale 1:1 (mm)
Robust HSS
Dipole HSS
1,00
0,50
100 0,00
0 1 2 3 4 5 mm
Operating Stroke = 4,3
SKS
90
INGUN E-TYPE® probes are supplied in all current grid sizes
(50, 75, 100 Mil), and are compatible with the standard
80 GKS-050/075/100/422 series.
Step Probes
GKS ... M
Rotating test probes are recommended for the secure con-
70
tact of heavily contaminated components, anodised alu-
minium, or similar plated surfaces.
60 During the contacting process, the rotating plunger of the
rotating GKS
VF / Non-
test probe pierces the surface of the PCB reliably penetrating
50 the contact surface.
However, it must be taken into consideration that the main-
tenance rate must be adjusted because of the increased
40
RF Test Probes
Dipole-GKS
amount of particles.
INGUN DKS-050/075/100 are 100% compatible with the
30 standard series GKS-050/075/100.
POS-NR.
POS-NR. BENENNUNG
POS-NR.BENENNUNG
POS-NR.BENENNUNG BESCHREIBUNG
BENENNUNG BESCHREIBUNG MENGE
BESCHREIBUNG MENGE
BESCHREIBUNG MENGE
MENGE
1 1 Milimetereinteilung
Milimetereinteilung
1Katalog
Katalog
Milimetereinteilung
Milimetereinteilung
1Katalog 1 1 1 1
Katalog
10 2 2 E-050 E-050
214 050
214
2Katalog
Katalog
A050
2000
2E-050
Katalog
A 2000
214
E-050
050214
Katalog
A 2000
050 A 2000 1 1 1 1
POS-NR. POS-NR. BENENNUNGBENENNUNG
5 4
5
E-100 E-100
5 E-4225
291 090
4 Katalog
E-422
291
4Katalog
209 080
209
5
A090
2000
E-100
4Katalog
A080
A 2000
291
E-100
090291
Katalog
2208
E-422 A 2208
209
E-422
A 2000
080209
090 A 2000
A 2208
080 A 2208
1
1
1
1
1
1
1
1
POS-NR.
1
POS-NR.
POS-NR.
BENENNUNG BENENNUNG Katalog Katalog
BENENNUNG
1 Millimetereinteilung
1 Millimetereinteilung
Katalog
DKS-050
Millimetereinteilung
Katalog
Katalog
2 207
DKS-050
2 Katalog
1500
090 G207 090 G
1500 Katalog
Katalog
KatalogKatalogKatalog DKS-075 217
DKS-075
120 G217 120 G
2 2 DKS-050
DKS-050
207
2 KatalogDKS-050
090
207G090
207G3 090 G1000
3 Katalog
1000 Katalog
0
1500 1500 Katalog
1500 Katalog
Assorted
3 3 DKS-075
DKS-075
217
3 KatalogDKS-075
120
217G120
217G4 120 GDKS-100 217
DKS-100
4 Katalog
1000
150 G217 150 G
1000 Katalog
1000 1000 Katalog
1000 Katalog
GKS
90
GKS-725 207
GKS-725
130 R 207 130 R
4 4 DKS-100
4 DKS-100
217
1000 Katalog
DKS-100
150
217G150
1000 Katalog
217G
1000 Katalog
5 150 G1507
5 S Katalog
1507 S Katalog
GKS-725
GKS-725
207GKS-725
130
207R130 GKS-713
2076R 130 R 6 207
GKS-713
225 R 207 225 R
5 5 1507
5 S1507
DKS-050
DKS-075
DKS-100
GKS-725
GKS-713
Katalog
S1507
Katalog
S Katalog 3007 Katalog
3007 Katalog
6 GKS-713
GKS-713
207
GKS-713
225
207R225
207R 225 R
E-050
E-075
E-100
E-422
6 6 Katalog
3007 3007 Katalog
3007 Katalog
-10
80
Accessories
-20 Note:
70 See page 22 for overview
and comparison table.
-30
60 Shown without KS - other installation heights available
-40
Tools
41
50 41
INGUN E-TYPE® Grid:
1,27 / 1,91 mm
E-050 / E-075 50 / 75 Mil
Installation height with KS: 16,0 mm (.630) / variable
Recommended stroke: 4,3 mm (.169)
Material
Plating
versions
Tip style
E - 050 ø0,78 (.031) ∅
ø0,5 (.020) ∅ (inch)
2 01 ∅ 0,50 A
6,9 (.272) (.020)
43,2 (1.700)
øs. tbl.
3 07 ∅ 0,50 A 0,90 A
(.020)
6,4 0,5
(.250) (.020) 2 14 ∅ 0,50 A
43,2 (1.700) (.020)
6,4 1,3
∅ 0,50
33,1(1.303) (.250) (.051) 2 97 (.020)
A
Spring Force
Further
Material
Plating
versions
Tip style
2,0 ∅ ∅ (inch)
2,0N
(7.2) E - 050
2,0N
-050
1,0 G KS 2 01 ∅ 0,64 A
(3.6) (.025)
(.025)
,8 N
7 52
S-0
3,0 GK 2 14 ∅ 0,50 A
(10.8) ,0N (.020)
-0 75 2
2,8N G KS
2,0 75 5 2,0 N
E-0 E - 07
(7.2)
2 14 ∅ 0,64 A 1,00 (.039)
1,0 (.025)
(3.6)
24
0 1,0 2,0 3,0 4,0 5,0 6,0 Stroke in m m 2 * A
(.039) (,079) (.118) (.157) (.197) (.236) (inches) ∅ 1,30
(.051)
Test probes: E 0 5 0 2 9 1 0 5 0 A 2 0 0 0
E 0 7 5 2 9 1 0 6 4 A 2 0 0 0
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil
Installation height with KS: 16,0 mm (.630) / variable
ICT-/FCT Test Probe
E-100Kontaktieraufgaben
/ E-422
ICT-/FCT-Kontaktstifte
for difficult contacting
für schwierige
demands
Standard
GKS
Mounting and functional dimensions Available tip styles E-100
Further
Material
Plating
versions
Tip style
E - 100 ∅
ø1,37 (.054) ø0,9 (.035) ∅ (inch)
E-TYPE
DKS
2 01 ∅ 0,90 A
8,4 (.331) (.035)
33,4 (1.315)
øs. tbl.
3 07 ∅ 0,90 A
(.035)
Flying Probe
Bead Probe
6,4 2 (.079)
3 07 ∅ 1,50 A
(.250) (.059)
33,4 (1.315)
2 09 ∅ 0,60 A
ø1,66 (.065) ø2 (.079) ø1,3 (.051) (.024)
Fine Pitch
2 14 ∅ 0,50 A
8 8 (.020)
(.315) (.315)
38,4 (1.512)
ø s.tbl. 2 14 ∅ 1,30 A
E - 422 (.051)
Stand. GKS
24
Metric
2 ∅ 1,30 A
5 8 3 *
(.051)
(.197) (.315) (.118)
38,4 (1.512)
2 38 ∅ 0,90 A
(.035)
Spring Force
Spring Force
short / long
Maximum stroke: 8,0 mm (.315)
2 77 ∅ 0,90 A
in N (oz.)
in N (oz.)
HSS
Operating stroke: 6,4 mm (.250)
(.035)
,0 N
0 03 3,0
N
S-1 22
GK S-4
GK ∅ 0,90 A
3,0 3,0 2 91
(10.8) 2,0N (10.8) ,25N (.035)
422 2
0 3,0N -100 GKS-
E - 10 G KS 2 3,0N
2,0 2,0N 2,0 E - 42
E - 100 2,25N
Robust HSS
(7.2)
Dipole HSS
(7.2) E - 422
2 97 ∅ 0,90 A
1,0 1,0 (.035)
(3.6) (3.6)
SKS
Collar height and installation height, receptacles, electrical
data, operating temperature, mounting hole size and materials: Available tip styles E-422
(.315)
(.197)
Plating
versions
8
Tip style
5
∅ ∅ (inch)
Step Probes
e-type Compatible probe Page
GKS ... M
E-100 GKS-100 28 / 29 2 01 ∅ 1,30 A
(.051)
E-422 GKS-422 63
E - 100 in E - 422 in 3 07 ∅ 1,30 A
KS -100 KS -112 (.051)
rotating GKS
Spring forces at working stroke
VF / Non-
Series Designation Pre-load Force at work. stroke 09 A
2 ** ∅ 0,80
(.011)
E-100 20 1,3 N (4.7 oz) 2,0 N
E-100 30 2,0 N (7.2oz) 3,0 N 2 14 ∅ 1,30 A 2,00 (.079)
(.051)
RF Test Probes
Dipole-GKS
2 91 ∅ 1,30 A
(.051)
Mechanical data E-422
Working stroke: 6,4 mm (.250) ** pressed-in steel point in base plunger made of brass
Maximum stroke: 8,0 mm (.315) *** higher middle tip plus 0,5 mm
Assorted
GKS
Series Tip Tip style Tip diameter Plating Spring force Collar height
Ordering example material (1/100 mm) A = Gold (dN) 00 (E-100)
2 = Steel N = Nickel 05 (E-422) tip-∅ > 1,3 mm
3 = BeCu 08 (E-422) recomm. for
tip-∅ < 1,3 mm
Accessories
Test probes: E 1 0 0 2 9 1 0 9 0 A 3 0 0 0
E 4 2 2 2 1 4 2 0 0 A 3 0 0 5
E 4 2 2 2 9 1 1 3 0 A 3 0 0 8
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
6,9 (.272)
43,2 (1.700)
Material
(.040) Further versions
Plating
Tip style
∅ ∅ (inch)
7,7 (.303)
33,1 (1.303) 3 07 ∅ 0,76 G
(.026)
8,4 (.331)
33,4 (1.315)
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
3 07 ∅ 1,00 G
(.039)
2 17 ∅ 1,50 G
16 (.059)
Test probes: D K S 0 5 0 2 0 7 0 9 0 G 1 5 0 0
D K S 0 7 5 2 1 7 1 2 0 G 2 0 0 0
D K S 1 0 0 2 1 7 1 5 0 G 2 0 0 0
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Rotating Test Probe
Installation height with KS: 13,0 resp. 16,0 mm (.512 / .630)
Recommended stroke: 4,8 resp. 4,0 mm (.189 / .157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 1,37
E-TYPE
ø 1,8 ø1 ø 1,3
DKS
(.054) (.071) (.039) (.051) 2 07 ∅1,30 R
(.051)
GKS-725 207
7,5 6 2 (.079)
(.295) (.236) 2 57* R
∅ 1,00
15,5 (.610) (.039)
Flying Probe
Bead Probe
33 (1.299) *3 mm (.118) shorter
ø 1,8 ø1
(.071) (.039)
GKS-725 257
7,5 5
Fine Pitch
(.295) (.197)
12,5 (.492)
30 (1.181)
Stand. GKS
(.024) (.066) (.071)
Metric
KS-725 47
9,3 0,5
(.366) (.020)
31,8 (1.252)
short / long
HSS
Robust HSS
Dipole HSS
16 (.630)
16 (.630)
13 (.512)
SKS
KS (inch) (inch) (inch)
07 16 mm 4,8 6,0 mm
GKS-725 257
GKS-725 207
Step Probes
57* 13 mm 4,0 5,0 mm
GKS ... M
(.512) (157) (.197)
rotating GKS
Maximum stroke: see table above Barrel: Brass, gold-plated
VF / Non-
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated guarantees a secure fit in the recepta-
Receptacle: Brass, gold-plated cle or probe plate.
Electrical data Mounting hole size The KS-725 47 receptacle can be used
Current rating: 3-4A in material CEM1 and FR4: with the standard GKS-100 test probe
RF Test Probes
Dipole-GKS
Ri typical: < 20 mW with receptacle: ∅ 1,67 mm (.0657) series (see assembly drawing).
without receptacle: ∅ 1,37 mm (.0539)
Operating temperature
Standard: -40° up to +80° C
PKS
PSK
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
Assorted
2 = Steel
Test probe: G K S 7 2 5 2 0 7 1 3 0 R 1 5 0 7 S
Accessories
Receptacle: K S – 7 2 5 4 7
Tools
Material
Further versions
Plating
Tip style
ø 1,3 [.051] ø 2,65 [.104] ø 3,6 [.142] ø 2,25 [.089] ∅ ∅ (inch)
2 06 R 4,00 R
GKS-713 207 ∅ 2,25
2 56 R
* ∅ 2,25
GKS-713 257
2 57 R
6 [.236] * ∅ 2,25
solder connection
ø 2,45 [.096]
ø 1,7 [.067] ø 3 [.118] ø 3 [.118] ø 3,2 [.126]
KS 713 23
0,2 [.008]
23 [.906]
18 [.709]
13 [.512]
7 [.276]
7 [.276]
Operating temperature
Standard: -40° up to +80° C
Test probe: G K S 7 1 3 2 0 6 2 2 5 R 1 5 0 7
Receptacle: K S – 7 1 3 2 3 K S – 7 1 3 3 5
Lamellar plug: S E – 5 0 3
(for plugging onto the end of the plunger)
Bead Probe
Standard
GKS
Flying Probe
E-TYPE
DKS
Flying Probe
Bead Probe
Bead Probe
GKS-050 48
Bead probes are used to contact small solder beads directly GKS-075 48
on PCB tracks or micro-vias (bead probe technology). To
Fine Pitch
GKS-100 48
ensure optimal contact with the various bead geometries, GKS-135 48
configurations, and surfaces, the largest selection of tip GKS-550 48
styles on the market is available from INGUN.
Stand. GKS
Flying Probe
Metric
INGUN bead probe test probes are 100% compatible with
the standard GKS-050/075/100/135 series.
GKS-112 MD 49
short / long
HSS
Scale 1:1 (mm)
Robust HSS
Dipole HSS
100
The tip-style 02 – flat - is The tip-style 60 – fine-serrated The multi-blade tip style 79
90 preferably used for flux-free – is recommended (due to the (star) is recommended for long,
and/or small beads. fine, aggressive points) for narrow, or large beads with
SKS
breaking open the surfaces of solder flux deposits thanks to
80 the beads, which are coated the self-cleaning horizontal
with flux-deposits. cutting edge.
70
Step Probes
GKS ... M
60 Flying test probes are used in flying probe systems.
Maximum precision and contacting accuracy is achieved by
rotating GKS
50 the geometry of the barrel, as well as the specialised bea-
VF / Non-
ding, which enables contacting in 0.15 mm grids.
40 INGUN recommends the GKS-112 MD series for use in the
flying probe system from Scorpion/Acculogic and Digital- RF Test Probes
test.
Dipole-GKS
30
10
PKS
PSK
100
5
POS-NR.
POS-NR. BENENNUNG
BENENNUNG
0 1 1 GKS-112
GKS-112
3005 3005
259 060
259A060 A
MD Katalog
MD Katalog
90
2 2 Milimetereinteilung
Milimetereinteilung
Katalog
Katalog
3 GKS-112
3 1510 GKS-112
201 108
201A108 A
1510
MDL Katalog
MDL Katalog
GKS-112 MDL
GKS-112 MD
Assorted
GKS
-10
80
-20
70
Accessories
Note:
-30 See page 22 for overview
60 and comparison table.
Shown without KS
-40
50
Tools
47
-50 47
40
GKS 050/075/100/135/550 Grid:
≥ 1,27 / 1,91 / 2,54 mm
ICT-/FCT Test Probes ≥ 50 / 75 / 100 Mil
for Bead Probes Contacting Installation height with KS: 16 mm (.630) / variable
Recommended stroke: 4,3 mm (.169)
Material
Material
Plating
6,4 0,5
Plating
Style ∅ (inch) Tip style ∅ (inch)
(.252) (.020)
43,2 (1.700)
3 60 ∅ 0,50 A 3 60 ∅ 0,90 A
6,4 0,5 (.020) Distance between points: 0,25 mm
(.035)
Distance between points: 0,15 mm
(.252) (.020)
34,60 (1.362)
3 79 ∅ 0,50 A
(.020)
GKS-075
Ø1,02 (.040) Ø0,64 Ø s. tbl. Available tip styles GKS-075 Available tip styles GKS-075
(.025)
GKS-075
3 02 ∅ 0,90 A 3 60 ∅ 0,90 A
6,4 1,3 (.035) Distance between points: 0,20 mm
(.035)
(.250) (.051)
33,1(1.303)
3 60 ∅ 0,64 A 3 79 ∅ 0,64 A
Distance between points: 0,20 mm (.025) (.025)
Ø1,37 Ø s. tbl.
GKS-100 (.054) Available tip styles GKS-100 Available tip styles GKS-100
GKS-100
3 02 ∅ 0,90 A 3 60 ∅ 0,90 A
6,4 2 (.079) (.035)
(.035) Distance between points: 0,20 mm
(.250)
33,4 (1.315)
3 02 ∅ 1,50 A 3 79 ∅ 0,64 A
(.060) (.025)
3 60 ∅ 0,64 A 3 79 ∅ 0,90 A
Distance between points: 0,20 mm (.025) (.035)
Test probes: G K S 0 5 0 3 6 0 0 6 0 A 1 5 0 0
G K S 5 5 0 3 6 0 0 6 0 A 1 5 0 0
G K S 0 7 5 3 6 0 0 9 0 A 2 0 0 0
G K S 1 0 0 3 6 0 0 9 0 A 2 0 0 0
G K S 1 3 5 3 6 0 0 9 0 A 2 0 0 0
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Test Probes for Flying Probe
Installation height with KS: 14,7 - 21,6 mm (.579 - .850) Test Systems Scorpion/Acculogic and Digitaltest
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
version GKS-112 ... 05 MD
M1,6 (.063) ø1,65 (.065) (.091) ø2,3 SW1,7 ø1
12°
°
Material
Further versions
22
Plating
(.067) (.039)
Tip style
GKS-112 201 112 A xx05 MD ∅ ∅ (inch)
E-TYPE
4,4 9,5 (.374)
DKS
(.173) 2 01 ∅ 1,12 A
40 (1.575)
(.044)
(.051) ø1,3
Flying Probe
Bead Probe
40 (1.575) (.209) (.165)
Fine Pitch
ø0,63 (.025)
Material
Further versions
Plating
Tip style
Stand. GKS
∅ ∅ (inch)
M1,6 (.063) ø1,65 (.065) (.098) ø2,5 SW2 (.079) ø1
Metric
°
8°
(.039)
22
short / long
(.043)
°
8°
(.039)
17
HSS
2 91 ∅ 1,30 A
11,8 (.465) (.051)
46,9 (1.846)
(.051) ø1,3
3 03 ∅ 1,30 A
GKS-112 291 130 A xx10 MDL (.051)
Robust HSS
Dipole HSS
5,8 4,2 (.165)
45,1 (1.776) (.228)
(.051) ø1,3
SKS
Type Oper. Max. Inst.- Note:
Install. Height
Step Probes
GKS ... M
Recommended screw-in torque:
91...05 MD 4,0 (.157) 5,3 (.209) 14,7 (.579)
Min.: 3 cNm / Max.: 5 cNm
53...05 MD 4,0 (.157) 5,3 (.209) 14,7 (.579)
59...05 MD 4,0 (.157) 8,0 (.315) 18,2 (.717)
Electrical data
Current rating: 5-8A
rotating GKS
VF / Non-
01...10 MDL 4,0 (.157) 8,0 (.315) 19,8 (.780) Ri typical: < 20 mW
51...10 MDL 4,0 (.157) 8,0 (.315) 21,6 (.850) Operating temperature
91...10 MDL 4,0 (.157) 5,8 (.256) 19,8 (.780) Standard: -40° up to +80° C RF Test Probes
03...10 MDL 4,0 (.157) 8,0 (.315) 19,8 (.780)
Dipole-GKS
Test probe: G K S 1 1 2 2 0 1 1 1 2 A 1 5 0 5 M D
Fine Pitch
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Fine Pitch
GKS-038 52
Fine pitch test probes are used for test points positioned
GKS-061 52
close together, which cannot be contacted by standard test
Fine Pitch
GKS-080 53
probes. These test probes can be used either with or without GKS-081 54
a receptacle. GKS-069 55
GKS-079 56
Test
Scaleprobes used with receptacles are changed from top side
1:1 (mm) GKS-181 57
Stand. GKS
Metric
in the usual way, without breaking the electrical connection.
In order to avoid elaborate wiring of the receptacle, use of
100 pre-wired receptacles is preferred.
short / long
Test probes with a plug connection can be used without a
HSS
90 receptacle to enable them to also be used for small grids.
The plug is usually pressed or glued into the plug moun-
80 ting plate. The probes have a floating mount in the probe
plate and are centred and secured by means of a holding
Robust HSS
Dipole HSS
70 guide plate. This type of customising has the following
advantages:
60
- Contacting of very small pads (can be used in grids smaller
that probes with receptacles)
SKS
50 - High contacting accuracy due to low ‘wobble’ of the test
probe in the holding guide plate
40 - Sandwich assembly of test fixture possible
POS-NR. BENENNUNG BESCHREIBUNG
Step Probes
- Larger drilling tolerances permitted in the probe plate
GKS ... M
1 GKS-038 308 028 A
0400 Katalog
30 2 GKS-061 304 035 A
0602 Katalog
3 GKS-080 301 035 A
Scale 1:1 (mm) 0805 Katalog
20 4 GKS-081 354 050 A
rotating GKS
0800 Katalog
VF / Non-
5 GKS-069 201 051 A
1000 Katalog
10 GKS-079 301 050 A
100 POS-NR.
POS-NR.
POS-NR.
111
BENENNUNG
BENENNUNG
BENENNUNG
GKS-038
GKS-038
GKS-038
308
308
308
028
028
028
AAA
BESCHREIBUNG
BESCHREIBUNG
BESCHREIBUNG
6MENGE
MENGE
MENGE
111 1300 Katalog
5 0400
0400
0400
Katalog
Katalog
GKS-061
Katalog
GKS-061
GKS-061
304
304
304
035
035
035
AAA GKS-181 354 080 A
222 0602
0602
0602
Katalog
Katalog
Katalog 7 111
0800 Katalog
RF Test Probes
0 GKS-080
GKS-080
GKS-080
301
301
301
035
035
035
AAA
Dipole-GKS
333 0805
0805
0805
Katalog
Katalog
Katalog 111
90 GKS-081
GKS-081
GKS-081
354
354
354
050
050
050
AAA 8 Millimetereinteilung
444 0800
0800
0800
Katalog
Katalog
Katalog 111
Katalog
GKS-038
GKS-061
GKS-080
GKS-081
GKS-069
GKS-079
GKS-181
555 GKS-069
GKS-069
GKS-069
201
201
201
051
051
051
AAA 111
1000
1000
1000
Katalog
Katalog
Katalog
888 Millimetereinteilung
Millimetereinteilung
Millimetereinteilung 111
Katalog
Katalog
Katalog
-20
70
PKS
PSK
-30
60
-40
Assorted
GKS
50
-50
40
Accessories
-60 Note:
30 See page 22 for overview
Shown without KS - other installation heights available and comparison table.
-70
20
Tools
-80 51
10 51
5
GKS 038 / GKS 061 Grid:
≥ 0,64 mm
Micro-contacting ≥ 25 Mil
Installation height: 4,0 mm (.157)
Recommended stroke: 2,0 mm (.079)
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
3 02 ∅ 0,28 A
GKS 038
(.011)
90°
4 4
(.157) (.157)
24 (.945)
pre-wired version with enamelled copper wire ∅ 0,22 mm: see example below
5
Available tip styles
2 3,5
(.197)
Material
Further versions
Plating
(.079) (.138)
11(.433) 36,2 (1.425) Tip style
∅ ∅ (inch)
SE-061 GKS-061
3 04 ∅ 0,35 A
(.014)
Test probe: G K S 0 3 8 3 0 8 0 2 8 A 0 4 0 0
Test probe: G K S 0 6 1 3 0 4 0 3 5 A 0 6 0 2
Information
Grid:
Product
≥ 1,00 mm
≥ 40 Mil Test probe for Contacting in SMD-Technology
Installation height with KS: 10,5 mm (.413)
Recommended stroke: 3,0 mm (.118)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
without receptacle ∅ ∅ (inch)
E-TYPE
spring-loaded,
DKS
3 01 ∅ 0,35 A
not connected spring-loaded (.014)
with plunger ø 0,3 [.012] ø 0,35 [.014]
ø 0,7 [.028] ø 0,8 [.031] ø s. tbl. 3 02 ∅ 0,80 A
(.031)
Flying Probe
Bead Probe
GKS-080
3 [.118] 5 [.197] 1,5 [.059] 3 03 ∅ 0,80 A
(.031)
3,8 [.150]
22,3 [.878] 3 04 ∅ 0,80 A 0,50 (.020)
(.031)
with receptacle
Fine Pitch
3 05 ∅ 0,80 A
ø 0,7 [.028] ø 0,8 [.031] spring-loaded (.031)
Stand. GKS
3,8 [.150]
Metric
19,3 [0.76]
short / long
KS-080
HSS
0,25 [.010]
16 [.630]
Robust HSS
Dipole HSS
SE-111
5 [.197] 5 [.197]
11 [.433]
10,5 (.413)
5,2 (.205)
(.197)
10,3 (.405)
SKS
Collar height and installation height
5
Step Probes
GKS ... M
Collar height: 05
Installation height: 10,3 mm (.405)
(without receptacle)
without KS with KS
rotating GKS
Mechanical data Materials
VF / Non-
Working stroke: 3,0 mm (.118) Plunger: BeCu, gold-plated Note:
Maximum stroke: 3,8 mm (.150) Barrel: Brass, gold-plated When using receptacles choose probe
Spring force at work. stroke: 0,8 N (2.9oz) Spring: Steel, gold-plated version GKS-080 ... E (version without
Receptacle: Brass, gold-plated solder cup). RF Test Probes
Dipole-GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Special
Assorted
3 = BeCu ( “E”)
Test probe: G K S 0 8 0 3 0 1 0 3 5 A 0 8 0 5
Accessories
Receptacle: K S – 0 8 0
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
without receptacle ø 0,7 [.028] ø 0,82 [.032] ø 0,46 [.018]
3 51 ∅ 0,50 A
GKS-081 ... XX (.020)
(XX=collar height - collar height 7,5 [.295]
see table below)
40,2 [1.583] 3 54 ∅ 0,50 A
(.020)
ø 0,4 [.016] ø 0,7 [.028] ø 0,45 [.018]
2 91 ∅ 0,50 A
SE-081 (.020)
5 [.197] 5 [.197]
11 [.433]
KS-081 35 EXX
(XX=collar height -
0,25 [.010] see table below)
31 [1.22]
SE-081 E
5 [.197] 5 [.197]
11 [.433]
Collar Height
Collar Height
Receptacles: K S – 0 8 1 3 5 E 03 K S – 0 8 1 3 5 E 05 K S – 0 8 1 3 5 E 08
Information
Grid:
Product
≥ 1,27 mm
≥ 50 Mil Short-Stroke Test Probe
Installation height with KS: 6,7 mm (.264) / 6,3 mm (.248)/variable
Recommended stroke: 2,2 mm (.087)
Standard
GKS
Mounting and functional dimensions Available tip styles
Ø0,69 Ø0,51
Material
Further versions
Plating
Øs.tbl. Tip style
(.027) (.020)
∅ ∅ (inch)
E-TYPE
DKS
(.039) 2 01 ∅ 0,51 N 0,51 A (.020)
1 (.020)
3,8
16,5 (.650) (.150) 3 03 ∅ 0,90 A 1,52 (.060)
(.035)
Flying Probe
Bead Probe
Ø0,51
(.020) 2 05 ∅ 0,51 N
(.020)
3 05 ∅ 0,51 A
Ø0,72 Ø0,86 Ø 1 (.020)
(.028) (.034) (.039)
Fine Pitch
3 05 ∅ 0,80 A
KS-069 30 (.031)
5 1,35
(.197) (.053) 3 06 ∅ 0,90 A
16,3 (.642)
(.035)
Ø0,51 Ø0,72
Stand. GKS
Metric
(.020) (.028) 3 07 ∅ 0,90 A
(.035)
KS-069 35
2 14 ∅ 0,90 A
Ø0,94 - 1,02 (.035)
(.037 - .040)
short / long
2 17 ∅ 0,90 A
KS-069 30 G
HSS
(.035)
2,54
(.100)
17,5 (.689)
Robust HSS
Dipole HSS
6,7 (.264)
SKS
Designation Install. height with KS
KS-069 30 6,7 mm (.264)
Step Probes
KS-069 35 6,7 mm (.264)
GKS ... M
with with
KS-069 30 G 6,3 mm (.248)/variable KS-069 XX KS-069 30 G
Note:
Mechanical data Materials Series 069 can only be used with a
rotating GKS
VF / Non-
Working stroke: 2,2 mm (.087) Plunger: BeCu or steel, gold-plated receptacle.
Maximum stroke: 2,8 mm (.110) or chemically nickel-plated
Spring force at work. stroke: 0,7 N (2.5oz) Barrel: Nickel-silver, gold-plated The KS-069 is available pre-wired with
Alternative: 1,0 N (3.6oz) Spring: Steel, gold-plated 1 m wire AWG 26
Receptacle: Brass or Nickel-silver, (see ordering example). Recommended
RF Test Probes
Electrical data
Dipole-GKS
3 = BeCu
Test probe: G K S 0 6 9 3 0 6 0 9 0 A 0 7 0 0
Accessories
Receptacles: K S – 0 6 9 3 0 K S – 0 6 9 3 5 K S – 0 6 9 3 0 G
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 0,7 [.028] ø 0,46 [.018]
3 01 ∅ 0,50 A
(.020)
GKS-079
1,5 [.059]
14,5 [.571]
KS-079 35
0,2 [.008]
16,5 [.650]
KS-079 46
8,2 [.323] 0,2 [.008]
21,2 [.835]
(.067)
3,2 (.126)
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
material (1/100 mm) A = Gold (dN) (mm)
3 = BeCu
Test probe: G K S 0 7 9 3 0 1 0 5 0 A 1 3 0 0
Receptacle: K S – 0 7 9 3 5
Information
Grid:
Product
≥ 1,27 mm
≥ 50 Mil Test Probe for Contacting in SMD-Technology
Installation height: 10,5/13,0/16,0 mm (.413/ .512/ .630)
Recommended stroke: 5,5 mm (.217)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
without receptacle ø 1 [.039] ø 1,1 [.043] ø 0,8 [.031]
∅ ∅ (inch)
E-TYPE
GKS-181 ... XX
DKS
3 05 ∅ 0,80 A
(XX=collar height - (.031)
see table below) collar height 7,5 [.295]
39,8 [1.567] 3 51 ∅ 0,80 A
(.031)
ø 0,7 ø1
Flying Probe
Bead Probe
[.028] [.039] ø 0,75 [.030]
3 54 ∅ 0,80 A
(.031)
SE-111
5 [.197] 5 [.197] 2 91 ∅ 0,80 N
(.031)
11 [.433]
Fine Pitch
ø 1,01 [.040] ø 0,8 [.031]
with receptacle
GKS-181 ... 00
7,5 [.295]
34,9 [1.37]
Stand. GKS
Metric
ø 1,32 [.052] ø 1,42 [.056]
KS-181 35 EXX
(XX=collar height -
see table below)
0,25 [.010]
short / long
31 [1.220]
HSS
ø 0,9 ø 1,32
[.035] [.052] ø 1 [.039]
SE-101
Robust HSS
Dipole HSS
5 [.197] 5 [.197]
11 [.433]
Install. Height
Install. Height
Collar Height
SKS
are available.
Step Probes
GKS ... M
05 13,0 mm (.512)
08 16,0 mm (.630) without KS with KS
rotating GKS
The receptacle can be used from grid
VF / Non-
Maximum stroke: 7,5 mm (.295) or chemically nickel-plated
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Brass, gold-plated size 1,91 mm (75 Mil) upwards.
Alternative: 0,8 N (2.9oz) Spring: Steel, gold-plated
Receptacle: Brass, gold-plated
Electrical data RF Test Probes
Current rating: 2-3A
Dipole-GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
PKS
PSK
Receptacles: K S – 1 8 1 3 5 E 03 K S – 1 8 1 3 5 E 05 K S – 1 8 1 3 5 E 08
Accessories
Standard
GKS
(GKS with Collar)
E-TYPE
DKS
Flying Probe
Bead Probe
Metric Standard
GKS-112 61
Metric standards test probes stand out due to their high
Scale 1:1 (mm) GKS-912 62
degree of stability as well as their robustness and all feature
Fine Pitch
GKS-422 63
a pronounced collar (stop). GKS-412 64
GKS-204 65
100 The collar is available in various heights, depending on the GKS-102 66
series and the receptacle combination allows maximum in- GKS-502 67
Stand. GKS
GKS-113 68
Metric
90 stallation height flexibility.
GKS-913 69
GKS-103 70
In addition to the classic ICT/FCT applications, the metric
80 GKS-503 71
series also covers many specialised applications. Test probes
GKS-854 72
short / long
with continuous plungers can be used for higher currents or
HSS
70 precise measurements due to their low resistance.
Robust HSS
Dipole HSS
Versions with beading in the middle of the barrel are used to
50
contact small pads, because of their low ‘wobble’.
40
SKS
30
Step Probes
GKS ... M
10
100
5
0
rotating GKS
VF / Non-
90
GKS-112
GKS-912
GKS-422
GKS-412
GKS-204
GKS-102
GKS-502
GKS-113
GKS-913
GKS-103
GKS-503
GKS-854
-10
80
RF Test Probes
Dipole-GKS
-20
70
-30
60
Shown without KS - other installation heights available
-40
PKS
PSK
50
-50
40
Assorted
-60
GKS
30
-70
20
Accessories
Note:
-80
10 See page 22 for overview
and comparison table.
5
-90
0
Tools
59
-10 59
KS 112 Grid:
≥ 2,54 mm
Receptacles for GKS-112/412/422/912/HSS-118 ≥ 100 Mil
Receptacles in the KS-112 series are available with different collar heights, making variable
installation heights possible. *The number of variations can be increased by using spacers.,
which may, however, reduce the test probe‘s holding force in the receptacle. In such cases,
test probes with bent ends (end designation”B” = banana-shaped) should be used. The
receptacles KS-112 47... (with wire-wrap post) are sufficiently vacuum-sealed for use in
vacuum fixtures.
E5 0,2 (.008)
E2
Receptacles with solder terminal
Collar height
Order No.: Receptacle Type in mm
(inches)
ø2,2
(.087)
ø2
(.079) Example for use of KS-112 with various collar
KS–112 23 0,2 (.008) heights
26 (1.024)
ø2,2 ø2
(.087) (.079)
KS–112 30 0,2 (.008)
30 (1.181)
ø2,2 ø2
variable
(.087) (.079)
GKS
KS–112 30 E2 2 (.079) KS
2(.079) 30(1.181)
ø2,2 ø2
(.087) (.079)
KS–112 30 E5 5 (.179)
5 (.197)
30 (1.181)
Install. Height
28 (1.102)
11
(.422)
variable
Receptacles with press-ring GKS
ø2,08 ø2 GKS DS
(.082) (.079)
KS–112 30 G8 1 ... 8
8 (.315) (.039... .315)
30(1.181)
ø2,08 ø2
(.082) (.079)
KS–112 47 G8 8
8 (.315) 8,2 (.323)
(.039... .315) * Example of use of a receptacle with and
39 (1.535)
without spacer (restrictions see above)
Vacuum-sealed receptacles with wire-wrap-posts
Mounting hole size
ø 2,2 [.087] ø 2 [.079] 0,64 [.025] for KS with collar:
KS–112 47 0,2
CEM1: ∅ 1,98 - 2,00 mm (.0780 - .0787)
0,2 [.008] 8,2 [.323] (.008) FR4: ∅ 1,99 - 2,01 mm (.0783 - .0791)
36,2 [1.425]
ø 2,2 [.087] ø 2 [.079] 0,64 [.025]
KS–112 47 15 0,2
0,2 [.008] 15,2 [.598] (.008) Material
43,2 [1.701] for KS with collar:
ø 2,2 [.087] ø 2 [.079] 0,64 [.025] Brass or nickel-silver, gold-plated
KS–112 47 E2/E5
2 [.079] / 5 [.197] 8,2[.323] 2/5
(.079 / .197) Mounting hole size
38 [1.496] /41 [1.614]
for KS with press-ring
(press-ring pressed in mounting hole)
* Spacers to vary the installation height
CEM1 and FR4: ∅ 2,03 - 2,05 mm
ø1,7 ø2,2 ø2,2 ø2,2 (.0799 - .0807)
(.067) (.087) (.087) (.087)
Material
1 (.039) 1 2 (.079) 3 (.118) 5 (.197) for KS with press-ring:
Bronze, gold-plated
DS-112-01 DS-112 01 DS–112 02 DS–112 03 DS–112 05
Receptacles: K S – 1 1 2 3 0 K S – 1 1 2 4 7
Spacers: D S – 1 1 2 0 2 D S – 1 1 2 0 5
Insertion tools for all receptacles: S W K S - 1 1 2
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Test Probe
Installation height with KS: 10,5 - 26,3 mm (.413 - 1.035) / variable
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
ø 1,65 ø2 ø1 ø s.tbl. ∅ ∅ (inch)
(.065) (.079) (.039)
E-TYPE
∅ 1,00 R
DKS
2 01 A 0,80 (.031)
(.039)
Flying Probe
40,3 (1.587) with Collar Height 10
Bead Probe
1,00 (.039)
3 02 ∅ 2,00 A
1,50 (.059)
(.079)
1,40 (.055)
Plug 3 03 ∅ 2,00 A
(.079)
1,80 (.071)
VS-112 is used instead of a test probe to prevent receptacles being used
Fine Pitch
unnecesarily during maintenance.
2 04 ∅ 2,00 R 1,30 (.051)
ø 1,66 (.065) (.079) ø2 ø2(.079) (.079)
Stand. GKS
1,00 (.039)
Metric
3 05 ∅ 2,00 A 1,40 (.055)
(.079) 2,30 (.091)
ø1,8
06
0 ** A
Test probes with alternative collar heights ∅ 2,30
0,8
are available to adjust the installation height (.091)
short / long
of the tip (dimension without receptacle).
HSS
3 06 ∅ 2,00 A
(.079)
(.051)
Collar Total length Installation height 1,30 R
(.059)
∅ 2,00 R 1,50 R
height without receptacle 3 06 1,80 R (.071)
(.079 2,50 R (.098)
Install. Height
Robust HSS
02 32,3 mm (1.27) 10,3 mm (.406)
Dipole HSS
R 1,30 A
2 07 ∅ 2,00 (.051)
Collar Height
SKS
2 14 ∅ 1,30 A 1,30 R (.051)
07 37,3 mm (1.47) 15,3 mm (.602) (.051)
Step Probes
GKS ... M
without KS
10 40,3 mm (1.58) 18,3 mm (.720) 3 19 ∅ 1,80 A 2,00 A (.079)
(.071)
rotating GKS
Working stroke: 4,0 mm (.157) Plunger: BeCu or steel, gold-plated,
VF / Non-
Maximum stroke: 5,3 mm (.209) rhodium- or chemically nickel-plated
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Nickel-silver or brass, gold-plated
Alternative: 0,6 N (2.2oz); 0,8 N (2.9oz); Spring: Steel,gold-plated,stainless steel*(C)
2,25 N (8.1oz); 3,0 N (10.8oz); Receptacle: Brass, gold-plated
5,0 N (18.1oz)
RF Test Probes
Dipole-GKS
Operating temperature
Test probes with tip diameter < 1,0 mm Standard: -40° up to +80° C Note to GKS-112 and KS-112:
(.039) have a maximum stroke of 8,0 *with spec. designation"C": -100° up to Receptacles in the KS-112 series are
mm (.315) +200° C (0,8 N ; 1,5 N; 2,25 N; 3,0 N) used for the GKS-112 (page 60) test
Exception: 5,0 N-spring (18.1oz): max. probe series.
stroke is always 5,3 mm (.209). Electrical data
Current rating: 5-8A
PKS
PSK
Note:
Ri typical: < 20 mW (* < 100 mW) Screw-in versions shown on page 125.
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Special
Assorted
GKS
Test probe: G K S 1 1 2 2 0 4 1 3 0 R 1 5 0 2
Plug: V S – 1 1 2
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
0,60 R (.024)
ø1,66 ø2 ø1,3 ø s.tbl. 2 01 ∅ 1,30 A 0,80 R (.031)
(.065) (.079) (.051) (.051) 1,00 R (.039)
2 5 3 1,80 (.071)
(.079) (.197) (.118) 3 03 ∅ 2,00 A 2,50 (.098)
(.079) 3,50 (.138)
32 (1.260) with Collar Height 02
1,30 (.051)
2 04 ∅ 1,80 A
2,00 R (.079)
(.071)
0,70 (.028)
3 05 ∅ 2,00 A 1,40 (.055)
(.079) 1,50 (.059)
ø1,8
06 A
0 **
∅ 2,30
0,8
(.091)
2 06 ∅ 1,50 R
(.059)
1,40 A (.055)
3 06 ∅ 2,00 A 1,80 A (.071)
(.079) 2,50A (.098)
(.071)
Collar Height
2 33 ∅ 1,30 N
Mechanical data Materials (.051)
Working stroke: 4,0 mm (.157) Plunger: BeCu or steel, gold-plated,
Maximum stroke: 5,0 mm (.197) rhodium- or chemically nickel-plated 2 88 ∅ 2,30 A
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Nickel-silver or brass, gold-plated (.091)
GKS-912 test probes series. *** pressed-in steel tip in base plunger of brass
Electrical data
Current rating: 5-8A
Ri typical: < 20 mW (* < 100 mW)
Test probe: G K S 9 1 2 2 0 4 1 3 0 A 1 5 0 2
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil ICT-/FCT Test Probe
Installation height with KS: 16,2 - 24,0 mm (.638 -.945) / variable
Recommended stroke: 6,4 mm (.252)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
2 01 ∅ 1,30 A 1,30 R (.051)
(.051)
ø 1,66 [.065] ø 2 [.079] ø 1,3 [.051] ø s. tbl.
3 02 ∅ 2,00 A
(.079)
GKS-422 ... 05
Flying Probe
Bead Probe
5 [.197] 8 [.315] 3 [.118] 2 04 ∅ 1,30 A
(.051)
38,4 [1.512]
Fine Pitch
GKS-422 ... 08
ø1,8
06
0 ** A
8 [.315] 8 [.315] 0,8 ∅ 2,30
(.091)
38,4 [1.512]
1,30 (.051)
3 06 ∅ 2,00 A
1,60 (.063)
(.079)
Stand. GKS
Metric
3 07 ∅ 1,30 A
(.051)
0,80
09 A/G (.031)
2 *** ∅ 0,80 N
0,60 (.024)
(.031) A/N
short / long
Collar height and installation height
HSS
0,60 (.024)
2 14 ∅ 1,30 A
Test probes with tip-∅ > 1.3 mm generally (.051)
2,00 (.079)
have a collar height of 5 mm (collar height
05). 2 17 ∅ 1,80 A
A collar height of 8 mm (collar height 08) is (.071)
Robust HSS
recommended to provide more stability for
Dipole HSS
24
test probes with tip-∅ < 1.3 mm. 2 ** ∅ 1,80 A
** (.071)
SKS
2 91 ∅ 1,30 N 1,30
(.051) A/G (.051)
08 16 mm (.630)
(** Tip styles 00x: install. height 16,8 mm (.661)) 2 93 ∅ 1,60 A
(.063)
Step Probes
GKS ... M
** also available as tip style 0 02
*** pressed-in steel tip in base plunger made of brass
**** higher middle tip plus 0,5 mm
rotating GKS
VF / Non-
Mechanical data Materials
Working stroke: 6,4 mm (.252) Plunger: BeCu or steel, gold-plated
Maximum stroke: 8,0 mm (.315) rhodium- or chemically nickel-plated Note:
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Bronze, gold-plated Receptacles in the KS-112 series
RF Test Probes
Alternative: 0,8 N (2.9oz); 2,25 N (8.1oz); Spring: Steel, gold-plated
Dipole-GKS
Receptacle: K S – 1 1 2 4 7
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
2 01 ∅ 1,00 R
ø1,66 ø2 ø1 ø s.tbl. (.039)
(.065) (.079) (.039)
3 03 ∅ 1,80 A 2,00 A (.079)
(.071)
ø1,8
0 03* A
2 9,8 (.386) 3 ∅ 2,30
0,8
(.079) (.118) (.091)
37,8 (1.488) see table Collar Height
2 04 ∅ 1,30 R
(.051)
3 07 ∅ 1,30 R
(.051)
09
2 ** ∅ 0,70 N
(.028)
2 14 ∅ 1,30 A
(.051)
2 17 ∅ 2,00 A
(.079)
2 24 ∅ 2,00 R
(.079)
2 25 ∅ 1,50 R
Collar height and installation height (.059)
2 91 ∅ 1,30 A
Collar Total Installation height (.051)
Series Tip Tip style Tip diameter Plating Spring force Collar height
Ordering example material
0 = Delrin
(1/100 mm) A = Gold
R = Rhodium
(dN) (mm)
2 = Steel N = Nickel
3 = BeCu
Test probe: G K S 4 1 2 2 0 4 1 3 0 A 1 5 0 2
Receptacle: K S – 1 1 2 4 7
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Long-stroke Test Probe for Dual-stage Fixture
Installation height with KS: 16,2/18,2/23,2 mm (.638/ .717/ .913)
Recommended stroke: 8,0 mm (.315)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
2 01 ∅ 1,30 R
ø 1,65 [.065] ø s.tbl. (.051)
GKS-204 3 02 ∅ 1,80 A
3 [.118] 10 [.394] 3 [.118] (.071)
Flying Probe
Bead Probe
47,9 [1.886]
3 03 ∅ 1,80 A
(.071)
ø 2 [.079] ø 2,2 [.087]
2 04 ∅ 1,30 A
KS-204 30 (.051)
0,2 [.008]
Fine Pitch
39 [1.535] 3 05 ∅ 1,30 A
(.051)
Stand. GKS
Metric
2 07 ∅ 1,30 A
8,2 [.323] (.051)
46 [1.811]
2 09* ∅ 0,70 N 0,70 G (.028)
(.028)
short / long
KS-204 47 15
2 14 ∅ 1,30 A
HSS
15,2 [.598] (.051)
53 [2.087]
2 15* ∅ 1,80 A
(.071)
Robust HSS
Dipole HSS
2 24 ∅ 2,00 R
(.079)
Collar height and installation height
Test probes with alternative collar heights 2 91 ∅ 1,30 N 1,30 (.051)
collar height
(.051)
are available to adjust the installation height
10
23 [.906]
collar height
2 93 ∅ 1,60 A
18 [.709]
(.063)
05
SKS
16 [.630]
03
Step Probes
GKS ... M
05 47,9 mm 18,0 mm (.709)
10 47,9 mm 23,0 mm (.906)
rotating GKS
VF / Non-
Mechanical data Materials
Working stroke: 8,0 mm (.315) Plunger: BeCu or steel, gold-plated, Note:
Maximum stroke: 10,0 mm (.394) rhodium- or chemically nickel-plated Screw-in version shown on page 126.
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Nickel-silver or brass, gold-plated RF Test Probes
Dipole-GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
Assorted
2 = Steel R = Rhodium
3 = BeCu N = Nickel
Test probe: G K S 2 0 4 2 0 4 1 3 0 A 1 5 0 3
Accessories
Receptacles: K S – 2 0 4 4 7 K S – 2 0 4 4 7 1 5 K S – 2 0 4 3 0
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
2 01 ∅ 1,00 A
0,64 ø2 ø 2,3 ø1 ø s.tbl.
(.039)
(.025) (.079) (.091) (.039)
KS -102 23 3 05 ∅ 1,40 A
0,25 (.055)
26 (1.024) (.010)
3 06 ∅ 1,40 A
(.055)
2,2 (.087)
height.
Installation height
Collar height
without receptacle
02
12.5 mm (.492)
Tip style 01 to 06 without with
KS KS
02
13.5 mm (.531)
Tip style 50*
1 = Brass P = PVC
2 = Steel
3 = BeCu
Test probe: G K S 1 0 2 1 0 2 1 4 0 A 1 5 0 2 W
Receptacle: K S – 1 0 2 2 3
Spacers: D S – 1 0 2 0 3 D S – 1 0 2 0 6
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Test Probe with Continuous Plunger
Installation height with KS: 12,2 resp. 13,2 mm (.480/ .520)
Recommended stroke: 5,6 mm (.220)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
continuous plunger
E-TYPE
ø 1 [.039] ø 2 [.079] ø 2,3 [.091] ø 1 [.039] ø s.tbl.
DKS
3 02 ∅ 1,40 A
(.055)
GKS-502
3 03 ∅ 1,80 A
7,1 [.280] 2 [.079] 3 [.118] (.071)
Flying Probe
Bead Probe
7 [.276]
39,1 [1.539] 3 04 ∅ 1,40 A
(.055)
Fine Pitch
53
3 ** ∅ 2,50 A
0,25 [.010] (.098)
22 [.866]
56
3 ** ∅ 2,50 A 2,50 R (.098)
(.098)
ø 2 [.079] ø 1,7 [.067]
Stand. GKS
ø 1 [.039] ø 1,2 [.047] ø 2 [.079] ** tip length 4 mm (.157)
Metric
*** tip length 4 mm (.157), special designation"L"
short / long
SE-502
HSS
SE-415 KS
Robust HSS
Dipole HSS
Collar height and installation height
The installation height of the tip (dimension
(.482)
height.
12,25
(.079)
2 (.087)
12,2
SKS
Collar Tip style Install. height
2,2
height with KS
02 02 / 03 / 04 12,2 mm (.4803)
02 33 / 53 / 56 13,2 mm (.5197)
Step Probes
GKS ... M
Mechanical data Materials
rotating GKS
Note:
VF / Non-
Working stroke: 5,6 mm (.220) Plunger: BeCu or steel,
Maximum stroke: 7,0 mm (.276) gold- or rhodium-plated The receptacle can be used from grid
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Brass, gold-plated size 3,50 mm (140 Mil) upwards.
Alternative: 0,8 N (2.9oz); 3,5 N (12.5oz); Spring: Steel, gold-plated or stainless steel*
5,0 N (18.1oz) Receptacle: Brass, gold-plated RF Test Probes
Dipole-GKS
3 = BeCu
Test probe: G K S 5 0 2 3 0 2 1 4 0 A 1 5 0 2
Accessories
Receptacle: K S – 5 0 2 2 3
Material
Further versions
Plating
ø2,7 ø3,2 øø32,65ø1, 8 ø s. 3 tbl.ø1, 8 ø s. tbl. Tip style
ø2,7 ø3, 2 ø2,7 ø3,ø2 2,65 ∅ ∅ (inch)
(.106) (.126)(.104) (.104) (.071)(.118)
(.118) (.071)
(.106) (.126) (.106)ø (.126)
2,65 ø 3 ø1, 8 ø s. tbl.
ø2,7 ø3, 2
(.106) (.126) (.104) (.118) (.071) 2 01 ∅ 1,80 R
(.197) 5 (.197)
(.118) 53 (.118) 2 23 (.079) 2 1(.079) (.079) 2 5, 3(.079) 2 5, 3 3 (.118)
3 (.118) (.071)
(.031)
(.197) 5 (.118) 3 2(.079)
(.079) (.039) 3 (.118) (.209)
(.079) 2 5, 3 (.209) ∅ 1,40 0,80
1,00 (.039)
DS -113 05 DS -113 03
05 DS
DS -113 03 DS
-113 02
DS-113 -113 02
DS-113 01 27,3 (.209) 3 02
(.055)
A 1,80 (.071)
27,3 (1.075) with (1.075)
collar with02collar height 02
height ∅ 2,30
DS -113 05 DS -113 03 DS -113 02 3,00 (.118)
(.091)
27,3 (1.075) with collar height 02 4,00 (.157)
ø3 ø 3,2 ø 3 ø 3,2ø 2, 9 ø 2, 9
(.118) (.126)(.114) (.114)
ø 3 (.118)
ø 3,2(.126) ø 2, 9 2 03 ∅ 3,00 A
(.118)
(.118) (.126) (.114)
0, 2 0, 7
2 7
23 (.906) 23 (.906) (.276) (.276) 3 03 ∅ 2,30 A 4,00 R (.157)
(.008) 7(.008) 25 (.984) 25 (.984) (.091)
KS -113 23 0, 2
KS -1132323(.906) (.276)
(.008) KS -113 3025KS -113
(.984) 30
KS -113 23 1 1 1,80 A (.071)
(.039)
KS
(.039) -113 30 2 04 ∅ 2,30 R
3,00 (.118)
1 (.091)
(.039)
0,80 (.031)
20 (.787) 20 (.787) 3 05 ∅ 2,30 A 1,40 (.055)
20 (.787) 43 (1.693) 43 (1.693) (.091) 3,00 R (.118)
2 07 ∅ 3,00 A
(.118)
Collar height and installation height
The installation height of the tip (dimension 3 07 ∅ 4,20 R
measured with receptacle) is defined by the (.165)
10,5(.413)
2,2(.087)
10,3 (.406)
2 (.079)
collar height.
3 12 ∅ 1,80 A
(.071)
ø2,3
10 18,5 mm (.728) without KS with KS
15
2 ** A
∅ 1,00
Mechanical data Materials Tip 2,5 mm (.0984) longer (.039)
Working stroke: 4,0 mm (.157) Plunger: BeCu or steel, gold-, 1,80 (.071)
Maximum stroke: 5,3 mm (.209) rhodium- or chemically nickel-plated 2 17 ∅ 2,30 R
3,00 A (.118)
(.091)
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Brass, gold-plated
Alternative: 0,3 (1.1oz); 0,6 (2.2oz); Spring: Steel, gold-plated or 3 19 ∅ 4,00 A 3,00 (.118)
1,0 (3.6oz); 2,25 (8.1oz); 3,0 (10.8oz); stainless steel*(C) (.157)
5,0 N (18.1oz) Receptacles: Brass, gold-plated
3 72 ∅ 1,80 A
(.071)
Electrical data Mounting hole size
Current rating: 5-8A for GKS-113 and KS-113:
2 87 N 4,00 (.157)
Ri typical: < 30 mW (*< 100 mW) with receptacle: ∅ 2,98 - 2,99 mm ∅ 2,60
(.102)
(.1173 - .1177)
without receptacle: ∅ 2,65 mm (.1043) 2 88 ∅ 2,30 A
(.091)
Operating temperature
** pressed-on steel Tip in base plunger made of brass
Standard: -40° up to +80° C Note:
*with Spec. Designations "C": -100° up to Screw-in version shown on page 128.
+200° C (1,5 N; 2,25 N; 3,0 N)
Ordering example Series Tip
material
Tip style Tip diameter
(1/100 mm)
Plating
A = Gold
Spring force
(dN)
Collar height
(mm)
Special
designation
2 = Steel R = Rhodium (alternative
3 = BeCu “C”)
Test probe: G K S 1 1 3 3 0 6 2 3 0 R 1 5 0 2
Receptacles: K S – 1 1 3 2 3 K S – 1 1 3 3 0 K S – 1 1 3 4 6
Spacers: D S – 1 1 3 0 2 D S – 1 1 3 0 3 D S – 1 1 3 0 5
Information
Grid:
Product
≥ 4,00 mm
≥ 160 Mil Short-stroke Test Probe: can be soldered
Installation height: 7,3 / 9,0 mm (.287 / .354)
Recommended stroke: 2,8 mm (.110)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
GKS-913 Tip style
∅ ∅ (inch)
ø 2,65 ø3 ø 3,5 ø s. tbl. ø 1,5 ø 2,65 ø3 ø 1,8
E-TYPE
(.104) (.118) (.138) (.059) (.104) (.118) (.071)
DKS
1 02 ∅ 2,30 A 3,50 (.138)
(.091)
Flying Probe
Bead Probe
Type 0 Type 1 3 05 ∅ 2,30 A
(.091)
ø2,3 0,3
ø 2,65 ø 3,5 ø s. tbl. ø 2,65 ø 3 ø 3,5 ø s. tbl. 3 06* A
(.104) (.138) (.104) (.118) (.138) ∅ 1,80
(.071)
Fine Pitch
3,50 R (.138)
2,1 (.083) 3,5 1,6 0,8 (.031) 3 06 ∅ 2,30 A
2,30 R (.091)
2,1 (.083) 3,5 1,6 (.091)
(.138) (.063)
15,1 (.594) (.138) (.063)
15,1 (.594)
Type S Type Z 3 08 ∅ 2,30 R
(.091)
Stand. GKS
Metric
58
3 ** R
ø 2,08 ø3 ø 3,3 ∅ 2,30
Tip length: 3,4 mm (.134) (.091)
(.082) (.118) (.130)
0,2
short / long
13,6 (.535) (.008)
Collar height and installation height
HSS
KS -913 35
for Type 0, S, Z res. 0C, SC, ZC The installation height of the tip is defined
by the collar height.
Robust HSS
Dipole HSS
Collar Tip style Install. height max. stroke
height without KS mm
in mm
Mechanical data Materials
Working stroke: 2,8 mm (.110) Plunger: Brass or BeCu, 02 02/05/ 7,2 (.283) 3,5 (.138)
Maximum stroke: shown on table on the gold- or rhodium-plated 06/08
right Barrel: Brass, gold-plated 02 06 180* 7,2 (.283) 3,2 (.126)
SKS
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated
Alternative: 0,8 N (2.9oz); 2,5 N (9.0oz) or stainless steel **** (C) 02 58** 8,8 (.346) 3,3 (.130)
Receptacle: Brass, gold-plated
Type 1 / 1C
Step Probes
GKS ... M
Operating temperature Mounting hole size Collar Tip style Install. height max. stroke
Standard: -40° up to +80° C in materials CEM1 and FR4: height without KS mm
*** with spec. designation "C": -100° with receptacle: ∅ 2,98 - 2,99 mm in mm
up to +200° C (1,5 N) (.1173 - .1177) 02 02/05/ 7,1 (.280) 3,5 (.138)
without receptacle: ∅ 2,65 mm (.1043) 06/08
rotating GKS
Electrical data
VF / Non-
02 06 180* 7,1 (.280) 3,2 (.126)
Current rating: 5 - 8 A (24 A****)
Ri typical: < 20 mW (***< 100 mW) 02 58** 8,7 (.343) 3,3 (.130)
Note (Type C probes are recommended for soldering): **** For applications up to 24 Amps: RF Test Probes
Version HSS-520 (M), see page 87.
Dipole-GKS
0C End of probe barrel open, danger of solder flux entering the probe
1C End of probe barrel with solder terminal
SC End of probe barrel closed; can be soldered into PCB Note:
ZC End of probe barrel closed; can be soldered into PCB Screw-in version GKS-913 M shown
on page 127.
Warning: Probes should be soldered with great care. Ensure the inside of the barrel is
PKS
PSK
not exposed to high temperatures, because this could destroy the spring.
The KS-913 35 receptacle can only be combined with the probe types 0, S, Z, 0C, SC
and ZC.
Assorted
GKS
Test probe: G K S 9 1 3 3 0 8 2 3 0 R 1 5 0 2 0
Receptacles: K S – 9 1 3 3 5
Tools
Mounting
GKS -103 and functional dimensions Available tip styles
Type "W" 8
(.079) 2 6, 3 4 (.157)
Material
(.315) Further versions
Plating
(.248)
1 37, 3 (1.469)
ø3 ø 3,5 ø 1,8 ø s.tbl.
Tip style
∅ ∅ (inch)
(.039) (.118) (.138) (.071)
GKS
GKS -103
-103 2 01 ∅ 1,80 A
Type "W" 8 (.071)
29, 3 (1.154)
(.079) 2 6, 3 4 (.157)
(.315)
(.248)
37, 3 (1.469)
ø3, 5 (.138) ø3, 9 ø3,05 ø3, 9 1 02 ∅ 2,30 A 4,00 (.157)
soldersolder connection
connection continuous
continuous plunger
plunger (.154) (.120) (.154) (.091)
GKS -103
ø 2,45ø [.096]
2,45 [.096]
KS -103 23 ø 3,5 ø[.138]
3,5 [.138] ø 1,8 ø[.071]
1,8 [.071]
ø 3,05ø [.120]
3,05 [.120] ø 3,9 ø[.154]
3,9 [.154]
* Use of test probe with DS-103 03 and DS-103 05 spacers
only possible with KS-103 23-2 (receptacle with stronger
crimp in upper crimp position).
2 [.079]
2 [.079] 3 [.118]
3 [.118] 5 [.197]
5 [.197]
DS-103 DS-103
05* 05*
DS-103 02 02 DS-103
DS-103 03* 03* DS-103
12,5 (.492)
12,3 (.484)
2,2(.087)
2 (.079)
Operating temperature
Standard: -40° bis +80° C
** with spec. designation "C":
-100° up to +200° C (1,5 N; 3,0 N; 5,0 N)
Test probe: G K S 1 0 3 2 0 1 1 8 0 A 1 5 0 2
Receptacles: K S – 1 0 3 2 3 K S – 1 0 3 2 3 - 2 K S – 1 0 3 3 0
Spacers: D S – 1 0 3 0 2 D S – 1 0 3 0 3 D S – 1 0 3 0 5
Information
Grid:
Product
≥ 4,00 mm
≥ 160 Mil Test Probe with Continuous Plunger
Installation height with KS: 13,2 mm (.520)
Recommended stroke: 5,6 mm (.220)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
2 01 ∅ 1,80 R
ø 2,45 [.096] ø 3,5 [.138] ø 1,8 [.071] (.071)
Flying Probe
Bead Probe
7 [.276] 8 [.315] 2[.079] 7 [.276] 4 [.157] 3 04 ∅ 4,00 R
(.157)
10 [.394] 38 [1.496]
2 05 ∅ 1,80 R
ø 3,5 [.138] ø 3,9 [.154] (.071)
Fine Pitch
R 3,00 R
3 06 ∅ 4,00 (.118)
KS-103 23 (.157)
A
0,25 [.010
2 06 ∅ 1,80 R
22 [.866] (.071)
Stand. GKS
Metric
ø 3,05 [.120] ø 3,9 [.154]
short / long
HSS
DS-103 02 DS-103 03* DS-103 05*
Robust HSS
Dipole HSS
13 (.512)
2 (.079)
SKS
height without receptacles
02 13,0 mm (.512)
Step Probes
GKS ... M
Mechanical data Materials
Note:
Working stroke: 5,6 mm (.220) Plunger: Steel or BeCu,
The receptacle can be used from grid
Maximum stroke: 7,0 mm (.276) gold- or rhodium-plated
size 4,50 mm (180 Mil) upwards.
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Brass, gold-plated
Alternative: 3,0 N (10.8oz), 5,0 N** Spring: Steel, gold-plated
rotating GKS
(18.1oz) or stainless steel**
VF / Non-
Receptacle: Brass, gold-plated
Test probe: G K S 5 0 3 2 0 1 1 8 0 R 1 5 0 2
Receptacles: K S – 1 0 3 2 3 K S – 1 0 0 2 3 - 2
Accessories
Spacers: D S – 1 0 3 0 2 D S – 1 0 3 0 3 D S – 1 0 3 0 5
Lamellar plug: S E – 5 0 3
(for plugging onto the end of the plunger)
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø3,47 ø3,5 ø4 ø2,5 Øs.tbl.
(.137) (.138) (.157) (.098) ∅ 4,00 A
3 06
(.157)
3 19 ∅ 4,00 A
(.157)
(.079) 2 5,5 3 (.118)
38,5 (1.516) (.217)
ø3,96 ø4 ø4,3
(.156) (.157) (.169)
KS-150 30
KS-150 M3
Test probe: G K S 8 5 4 3 1 9 4 0 0 A 3 0 0 2
Receptacles: K S – 1 5 0 3 0 K S – 1 5 0 M 3 - R
High current test probes are used in several industries and from each other in a radial direction. In doing so, the plun-
applications with high currents, such as testing, function ger parts press against the barrel and the transfer resistance
tests, signal transmission, power supply in production, as (Ri) is reduced. This principle allows the transmission of high
well as assembled contact elements. Another field of appli- currents with limited warming. The power loss, which causes
cation is precise measurement, which requires test probes warming, is calculated using the formula Pv=Ri*I².
with very low internal resistance, so-called low-Ohm test
probes. The permitted current load capacity of each test probe can
For secure transmission of high currents, the plungers in be taken from the current rating graphs. The maximum per-
INGUN high current test probes consist of two parts. During mitted ambient temperature at rated current can be found in
the stroke movement the plunger parts are deflected away the current de-rating graphs.
High current, precise measurements Limited installation space / Four-wire Flat connector blades / bolts Harsh ambient conditions
dual-stage fixture measurement
Dipole high
Standard high Standard high Short-stroke Robust high
Grid size / current High current
current test current test and long-stroke current probes
Series (max. probes clamps
probes probes high current test (probes / contact
current) (Kelvin (flat / round)
(press-in) (screw-in) probes terminal)
probes)
≥ 2.54 mm
HSS-118 (20 A) HSS-118 M (20 A) HSS-827 M (20 A) - - -
(≥ 100 Mil)
≥ 4.00 mm
HSS-120 (30 A) HSS-120 M (30 A) HSS-520 / M (30 A) VK-541 (10 A) KK-541 (20 A) -
(≥ 160 Mil)
≥ 5.08 mm HSS-552 M (50 A)
HSS-150 (50 A) HSS-150 M (50 A) - - -
(≥ 200 Mil) HSS-150 H / MH (50 A)
6.0 to 7.5 mm HSS-621 M (75 A) HSS-624 M HKF-617 (40 A)
- - -
(250 to 300 Mil) HSS-623 M (100A) (100 A) HKR-694 (40 A)
12.0 to 35.0 mm HKR-612 M (100 A) HSS-2259 (25 A) to
- - - -
(470 to 1400 Mil) HKR-672 M (200 A) HSS-2532 (400 A)
79 / 81 / 83 /
Page(s) 78 / 80 / 82 86 - 89 92 - 93 94 - 98 99
84 - 85
74
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
High Current Test Probes
(Low Ohm Test Probes)
Depending on the application and the related test demands,
Standard high current
INGUN offers various high current test probes (HSS):
Fine Pitch
test probes
(press-in/screw-in 78 - 85
Standard HSS are unrivalled HSS probes with an optimal
ratio of rated current load of 20 to 100 Amps in a compact Short-stroke
design. Both press-in versions and screw-in versions are high current test probes
Stand. GKS
available. 86 - 88
Metric
Short-stroke HSS and long-stroke HSS are used in appli- Long-stroke
high current test probes 89
cations where limited test space is available, or contacting
short / long
which requires a long stroke (e.g. dual-stage contacting). International standard
HSS
test probes 90
International standard probes are high current test probes
without a collar. The installation height of these probes is Dipole high current
adjusted using the receptacle. test probes 92 - 93
Robust HSS
Dipole HSS
Dipole high current probes (Kelvin probes) four-wire High current clamps
measurements can be performed to precisely define re- (flat/round) 94 - 98
sistance. In doing so, the voltage (V) on the inner conductor
Robust high current
and the current (A) on the outer conductor are measured.
SKS
test probes
(probe/contact terminal) 99
High current clamps (round/flat) are used to contact flat
connector blades and round posts, such as those found
in plug connectors. PCBs and threaded bolts can also be
Step Probes
GKS ... M
contacted.
Four-wire clamps are suitable for performing four-wire
measurements.
rotating GKS
VF / Non-
Robust high current probes are used wherever challenging
atmospheric conditions, side force or vibrations can occur.
These robust probes are also suitable as a permanently
assembled contact element in machinery. RF Test Probes
Dipole-GKS
Note:
See next page for overview
and comparison table.
Tools
75
75
Technical Information
Installation
Spring height with Min.
Grid Working Max. Current Compatible
High current probe (HSS) forces (N) receptacle probe
Series size stroke stroke rating test probes Page
version (KS) (mm) length
(≥ mm) (mm) (mm) (A) (GKS)
(mm)
min max min max
HSS-118 2.54 4 5.3 / 8 20 1.5 3 10.5 18.5 32.3 GKS-112 78
HSS-118 M 2.54 4 5.3 / 8 20 1.5 3 10.5 - 35.3 GKS-112 M 79
HSS-120 4 4 5.3 30 1.5 3 10.5 18.5 27.3 GKS-113 80
Standard high current HSS-120 M 4 4 5.3 30 1.5 3 10.5 - 28.3 GKS-113 M 81
test probes
(press-in/screw-in) HSS-150 5.08 4.4 5.5 50 3 10 10.8 - 38.5 GKS-854 82
HSS-150 M 5.08 4.4 5.5 50 3 10 10.8 - 43.1 GKS-854 M 83
HSS-621 M 6.35 4.4 5.5 75 5 10 10.8 - 43.1 - 84
HSS-623 M 7.6 4.4 5.5 100 7 15 10.8 - 52.1 - 85
HSS-827 M 2.54 3.5 4.5 20 1.5 2.5 8.7 - 19.5 GKS-427 M 86
Short-stroke high
HSS-520 (M) 4 2.8 3.5 30 1.5 - 7.3 7.4 15.1 GKS-913/M 87
current test probes
HSS-552 M 5.08 2 2.5 50 2 - 7.5 - 17.1 - 88
Long-stroke high HSS-150 H
5.08 7.4 8.5 50 3 10 13.8 - 46.1 - 89
current test probes (MH)
International standard
HSS-005 4.75 4.4 6.35 40 3 5 8.9 - 36.1 GKS-005 90
test probes
Dipole high current HSS-624 M 7.6 4.4 5.5 100 9 - 10.8 - 61.8 - 92
test probes / 4-wire clamp VK-541 3.5 3.5 6.5 10 - - 19.1 - 53.5 - 93
HKF-617 5.5 4.4 5.5 20/40 10 27.9 57.9 - 94
KK-541 3.5 3.5 6.5 20 - - 16.35 16.55 34.35 - 95
High current clamps 35/35/100
HKR-612 M 10-12.5 4.4 5.5 10 20 29.5 - 57 - 96
(flat / round)
HKR-672 M 18-22 4 5.5 200 20 - 33.5 34.7 72.7 - 97
HKR-694 5.5 4.4 5.5 15 10 26.2 56.2 - 98
HSS-2259 12 7 9.5 25 10 - 37.5 - 57.5 - 99
HSS-2513 16 7 10.5 35 12 - 52.5 - 79.5 - 99
Robust high current
test probes HSS-2516 20 7 12 100 17 - 54.2 - 81.2 - 99
(probe / contact terminal) HSS-2526 30 7 11 200 58 - 53 - 90 - 99
HSS-2532 35 7 11 400 116 - 53 - 114 - 99
Further technical information: Note: The measurements for the charts were conducted
The permitted current rating for each test probe can be using test probes with tip style 06 (serrated) and spring
taken from the current rating charts. The maximum per- force 1.5 N. Using other tip styles with smaller contact
mitted ambient temperature at nominal current can be surfaces reduces the nominal current rating. Furthermore,
read from the current de-rating charts. spring forces < 1.5 N are not recommended for high cur-
rent applications.
Example: HSS-150
76
Information
Product
Scale 1:1 (mm) Contents
Technical Information
Standard HSS
100
Standard
GKS
90
Short-stroke and Long-stroke HSS
80
International Standard Probes
E-TYPE
DKS
70
Flying Probe
60
Bead Probe
Standard High Current
50 Test Probes
Standard high current test probes are unrivalled, variable (press-in/screw-in)
Fine Pitch
HSS-118 78
current load of 20 to 100 Amps in a compact design. HSS-118 M 79
These probes are available with a wide range of tip styles HSS-120 80
30 and in a variety of diameters. In addition, a choice of spring
HSS-120 M 81
forces and various collar heights can be ordered to vary the HSS-150 82
Stand. GKS
20 installation height. HSS-150 M 83
Metric
HSS-621 M 84
Scale 1:1 (mm) HSS-623 M 85
10
5 Short-stroke High
short / long
0 Current Test Probes
HSS
100
HSS-118 M
HSS-120 M
HSS-150 M
HSS-621 M
HSS-623 M
HSS-118
HSS-120
HSS-150
HSS-827 M 86
-10 Scale 1:1 (mm) HSS-520 (M) 87
90
HSS-552 M 88
Robust HSS
Dipole HSS
-20
80 Long-stroke High
100 Current Test Probes
-30
70
90 HSS-150 H (MH) 89
SKS
-40
60 Shown without KS - other installation heights available International Standard
80 Test Probes
-50
50 Short-stroke high current test probes are ideally suited to
HSS-005 90
Step Probes
GKS ... M
70 applications with limited test space available. As with the
-60 standard probes, various mounting options are available.
40
60
-70 Long-stroke high current test probes are suitable for con-
30
rotating GKS
tacting situations which require a long stroke, e.g. dual-
VF / Non-
50
stage contacting.
-80
20
40 International standard probes are high current test probes
-90 without a collar. The installation height of these probes is
RF Test Probes
Dipole-GKS
10
30 adjusted using the receptacle.
5
0
20
Scale 1:1 (mm)
-10
PKS
PSK
10
5
-20
100 POS-NR.
POS-NR.
POS-NR.
POS-NR.
POS-NR.
BENENNUNG
BENENNUNG
BENENNUNG
BENENNUNG
BENENNUNG
0 11 1 Milimetereinteilung
Milimetereinteilung
Milimetereinteilung
1 Milimetereinteilung
Milimetereinteilung
HSS-150 MH
1
Katalog
Katalog
Katalog
Katalog
Katalog
HSS-827 M
HSS-552 M
22 2 HSS-827
HSS-827
HSS-827
HSS-827
302
302200
302
HSS-827
200S200
302
S1502
1502
S200
302
1502
S200
1502
S 1502
HSS-520
HSS-005
M2 M2Katalog
MKatalog
Katalog
M Katalog
M Katalog
HSS-520
HSS-520
33 3 1502
3 HSS-520
HSS-520
306
306230
306
HSS-520
230A230
306
A A 230
306A230 A
S3SKatalog
Assorted
15021502 Katalog
1502
S Katalog
1502
S Katalog
S Katalog
-30
90
GKS
HSS-552
HSS-552
44 4 2003
4 HSS-552
HSS-552
306
306400
306
HSS-552
400
4MKatalog A
400
306
A A400
306A400 A
20032003
M 2003
Katalog
M Katalog
2003
M Katalog
M Katalog
-10 55 5 HSS-150
HSS-150
5 HSS-150
5MHHSS-150
302
302400
302
HSS-150
400A400
302
A A 400
302A400 A
5002
50025002
MH 5002
Katalog
MH
Katalog
Katalog
5002
MH Katalog
MH Katalog
66 6 HSS-005
HSS-005
6
5000
5000
HSS-005
6
5000
HSS-005
306
306396
Katalog
306
Katalog
5000
HSS-005
396A
Katalog
5000
396
306
A A
Katalog
396
306A396 A
Katalog
-40
80
-20
Accessories
-50
70 Note:
-30
See page 76 for overview
Shown without KS - other installation heights available
-60
60 and comparison table.
-40
Tools
-70
50 77
-50 77
HSS 118 Grid:
≥ 2,54 mm
High Current Probe up to 20 A ≥ 100 Mil
Plug-in Test Probe Installation height with KS: 10,5 resp. 18,5 mm (.413/ .728)
Recommended stroke: 4,0 mm (.157)
Material
Further versions
Plating
ø 1 [.039] Tip style
∅ ∅ (inch)
ø 1,66 [.065] ø 2 [.079] ø s.tbl.
3 02 ∅ 1,00 A
HSS-118 (.039)
2 [.079] 3 [.118]
5,3 [.209] 3 03 A
∅ 2,00
(.079)
32,3 [1.272] (see table collar height)
KS-112 23
3 05 ∅ 1,00 A
(.039)
0,2 [.008]
1:1
26 [1.024]
3 05* S
∅ 2,00
ø 2 [.079] ø 2,2 [.087] (.079)
1,30 (.051)
KS-112 30 1,60 (.063)
3 06 ∅ 2,00
A 1,80 (.071)
2,50 (.098)
0,2 [.008] (.079) 3,50 (.138)
30 [1.181]
2 14 ∅ 1,30 A
ø 2 [.079] ø 2,2 [.087] (.051)
KS-112 30 E2
3 17 ∅ 1,75 A 2,00 (.079)
2 [.079] (.069)
30 [1.181]
ø 2 [.079] 3 19 A
ø 2,2 [.087] ∅ 2,00
(.079)
KS-112 30 E5
53 S
3 **
5 [.197] ∅ 2,00
30 [1.181] (.079)
Total length (mm) 32,3 32,3 34,3 35,3 36,3 37,3 38,3 39,3 40,3
Installation height
10,3 11,3 12,3 13,3 14,3 15,3 16,3 17,3 18,3
without receptacle (mm)
Test probe: H S S 1 1 8 3 0 6 2 0 0 A 1 5 0 2
Receptacles: K S – 1 1 2 2 3 K S – 1 1 2 3 0 K S – 1 1 2 3 0 E2 /E5
HSS 118 M
Information
Grid:
Product
≥ 2,54 mm
25,5 2 5,3 3 ≥ 100 Mil High Current Probe up to 20 A
35,8 height with KS: 10,5 mm (.413)
Installation Screw-in Test Probe
ø1,9 ø2
Recommended ø2,2stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
6 8 0,2
Material
35 Further versions
Plating
ø 1 [.039] Tip style
SW 1,7 [.067]
∅ ∅ (inch)
M1,6 [.063] ø 1,65 [.065] ø 2,3 [.091] ø s.tbl.
E-TYPE
DKS
3 02 ∅ 1,00 A
(.039)
HSS-118 ... M
ø1,95 ø2 ø2,05
2 [.079] 3 [.118] 3 03 ∅ 2,00 A
5,3 [.209] (.079)
Flying Probe
Bead Probe
35,8 [1.409]
5 10 0,2 3 05 ∅ 0,80 A 0,65 (.026)
33 ø 2 [.079] ø 2,2 [.087] 5 (.031)
0,6
KS-112 30 M-T 3 05 ∅ 1,00 A
(.039)
0,2 [.008]
Fine Pitch
8,2
35 [1.378] 1:1 05
3 ** S
37,2 ∅ 2,00
(.079)
KS-112 30 M **** (.051)
1,30
1,60 (.063)
3 06 A 1,80 (.070)
∅ 2,00 2,50
Stand. GKS
(.098)
KS-112 30 M-R (.079) 3,50
Metric
(.138)
0,2 [.008]
2 14 A
33 [1.299] ∅ 1,30
(.051)
ø 2,05 [.081]
ø 2 [.079] ø 2,2 [.087]
short / long
3 17 A 2,00 (.079)
∅ 1,75
HSS
(.069)
KS-112 30 M-R-Z ****
0,2 [.008] 3 19
∅ 2,00
A
35 [1.378] (.079)
Robust HSS
Dipole HSS
0,6 [.024] ø 2 [.079] ø 2,2 [.087] 53
3 *** S
∅ 2,00
(.079)
KS-112 46 M
8,2 [.323] 0,2 [.008] ** pressed-on silver head
** pressed-on silver head; tip length 3,5 mm (.138),
37,2 [1.465]
installation height plus 0,5 mm (.020)
SKS
**** axially positioned through-hole for leakage test. Attention:
when not assembled correctly, then solder can flow inside the receptacle.
Step Probes
Compatible GKS Electrical data Mechanical data
GKS ... M
GKS-112 M (assembled in same receptacle) Current rating (at room temp.): max. 20 A Working stroke: 4,0 mm (.157)
with spring force > 1,5 N and BeCu plunger Maximum stroke: 5,3 mm (.209)
Materials (*** spring force < 1,5 N not recommended for tip styles with diameter < 1 mm (.039)
Plunger: BeCu or steel, gold-plated for high current applications) Maximum stroke: 8,0 mm (.315)
Barrel: Brass, silver-plated Ri typical: < 10 mW Spring force at work. stroke: 1,5 N (5.4oz)
rotating GKS
VF / Non-
Spring: Stainless steel, gold-plated Current Rating Alternative: 0,8 N (2.9oz)***;
Receptacle: Brass, gold-plated T [°C] HSS-118 306 200 A 1502 M 2,25 N (8.1oz); 3,0 N (10.8oz)
100
80
Operating temperature 60
Spring Force Chart
Standard: -100° up to +200° C
RF Test Probes
Dipole-GKS
40 Spring Force
20 [N] Maximum
(Room Temperature 21 °C) Stroke
6,0
Mounting hole size 0
0 4 8 12 16 20 24
Working Stroke
20
in CEM1 and FR4: ∅ 2,00 - 2,02 mm
1,0
16
(.0787 - .0795) 12 0,0
0,0 1,0 2,0 3,0 4,0 5,0
8
4 Stroke [mm]
Recommended screw-in torque 0
Min. 3 cNm / Max. 5 cNm 0 20 40 60 80 100 120 140 160 180 200
Assorted
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm)
2 = Steel S = Silver
3 = BeCu
Accessories
Test probe: H S S 1 1 8 3 0 6 2 0 0 A 1 5 0 2 M
HSS 120
23
Grid:
ø2,9
≥ 4,00 mm
High Current Probe up to 30 A ≥ 160 Mil
Plug-in Test Probe Installation height with KS: 10,5 / 13,5 / 18,5 mm (.413 / .531 / .728)
7 Recommended stroke: 4,0 mm (.157)
25
1
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
20 Tip style
∅ ∅ (inch)
43
20 (.787) 3 19 A
∅ 3,00
43 (1.693) (.118)
2 51* ∅ 2,30 A
(.091)
53
3 *** ∅ 3,00 S
(.118)
3 55* ∅ 3,00 A
(.118)
(.1173 - .1177) 24
1,0
18 0,0
12 0,0 1,0 2,0 3,0 4,0 5,0
6 Stroke [mm]
0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
Test probe: H S S 1 2 0 3 0 6 3 0 0 A 1 5 0 2
Receptacles: K S – 1 1 3 3 0 K S – 1 1 3 2 3 K S – 1 1 3 4 6
Information
Grid:
Product
≥ 4,00 mm
≥ 160 Mil High Current Probe up to 30 A
Installation height with KS: 10,5 mm (.413) Screw-in Test Probe
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
SW 3
E-TYPE
M2 ø 2,65 ø 3,6 ø 1,8 ø s.Tb.
DKS
3 02 ∅ 2,30 A 4,00 (.157)
M2 ø2,65 ø3,6 SW3 ø1,8 øs.tbl. (.091)
GKS-113 ... M (.079) (.104) (.142) (.118) (.071)
HSS-120
HSS-120...
MM HSS -120 ... M 3 03 A
2 5,3 3 ∅ 3,00
Flying Probe
(.118)
Bead Probe
18 (.709)
28,3 2 5,3 3 (.118)
(.209)
∅ 1,40 A
ø 328,3 (1.114)
ø 3,2 3 05
5 (.055)
ø3 ø3,2
(.118) KS-113 30 M2-T
(.126) 3 05 A 3,00 (.118)
1:1 ∅ 2,30
(.091)
0,2 KS-113 30 M2-T KS-113 30 M2-T
Fine Pitch
7 27 8 0,2 05
3 *** S
∅ 3,00
(.276) 27 (1.063) (.315) (.118)
KS-113 30 M2 ***
3,00 (.118)
3 06 A 4,00
∅ 2,30 (.157)
KS 113 30 M2 *****
KS-113 30 M2 ***** (.091)
ø3 ø 3,05
Stand. GKS
Metric
ø3 Ø3,05
(.118) (.120)KS-113 30 M2-R 3 17 A
∅ 3,00
(.118)
KS-113 30 M2-R KS-113 30 M2-R
3 19 A
∅ 3,00
short / long
(.118)
KS-113 30 M2-R-S ****
HSS
51
2 ** ∅ 2,30 A
(.091)
(with additional crimp for self-restriction)
53
***** axially positioned through-hole for leakage test. 3 ** S
** ∅ 3,00
Attention: when not assembled correctly, then solder can flow inside the receptacle. (.118)
Robust HSS
Dipole HSS
55 A
3 **
∅ 3,00
(.118)
** tip length 5 mm (.197) -
installation height with collar height 02: 12,5 mm (.492)
*** pressed-on silver tip
**** pressed-on silver tip, tip length 3,5 mm (.138)
SKS
installation height plus 0,5 mm (.020)
Step Probes
GKS ... M
Materials Electrical data Mechanical data
Plunger: BeCu or steel, gold-plated Current rating (at room temp.): max. 30 A Working stroke: 4,0 mm (.157)
Barrel: Brass, silver-plated with spring force > 1,5 N and BeCu plunger Maximum stroke: 5,3 mm (.209)
Spring: Stainless steel, gold-plated (*spring force < 1,5 N not recommended for Spring force at work. stroke: 1,5 N (5.4oz)
Receptacle: Brass, gold-plated high-current applications) Alternative: 1,0 N* (3.6oz); 2,25 N (8.1oz);
Ri typical: < 10 mW 3,0 N (10.8oz)
rotating GKS
VF / Non-
Current Rating
Operating temperature T [°C] HSS-120 306 300 A 3002 M
Standard: -100° up to +200° C 100
80 Spring Force Chart
Spring Force RF Test Probes
60
Mounting hole size
Dipole-GKS
[N] Maximum
40 Stroke
for KS-113 30 M2 / M2-T 20
6,0
Working Stroke
5,0
in CEM1: ∅ 2,98 - 3,00 mm (.1173 - .1183) 0
(Room Temperature 21 °C)
4,0
in FR4: ∅ 2,99 - 3,01 mm (.1177 - .1185) 0 6 12 18 24 30 36
Current [A]
3N
3,0
for KS-113 30 M2-R / M2-R-S 2.25 N
Current Derating 2,0
in CEM1 and FR4: ∅ 3,00 - 3,02 mm Current [A] HSS-120 306 300 A 3002 M
1.5 N
1,0
(.1181 - .1189) 36
PKS
PSK
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm)
2 = Steel S = Silver
Accessories
3 = BeCu
Test probe: H S S 1 2 0 3 0 6 3 0 0 A 1 5 0 2 M
Receptacles: K S - 1 1 3 3 0 M 2 / M 2 -T K S - 1 1 3 3 0 M 2 -R / M 2 -R - S
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
HSS-150 3 03 A
∅ 4,00
(.157)
2 [.079] 3 [.118]
5,5 [.217]
3 05* S
38,5 [1.516] ∅ 4,00
(.157)
ø 4 [.157] ø 4,3 [.169]
3 06 A 3,00 (.118)
∅ 4,00
1:1 (.157)
KS-150 30
0,3 [.012] 3 17 A
∅ 3,00
40 [1.575] (.118)
3 19 A
M3 [.118] ø 4 [.157] ø 4,05 [.159] ø 4,3 [.169] ∅ 4,00
(.157)
40 [1.575]
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
material (1/100 mm) A = Gold (dN) (mm)
3 = BeCu S = Silver
Test probe: H S S 1 5 0 3 0 6 4 0 0 A 3 0 0 2
Receptacles: K S – 1 5 0 3 0 K S – 1 5 0 M3 - R
Information
Grid:
Product
≥ 5,08 mm
≥ 200 Mil High Current Probe up to 50 A
Installation height with KS: 10,8 mm (.425) Screw-in Test Probe
Recommended stroke: 4,4 mm (.173)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 2,5 [.098]
E-TYPE
SW 3,5 [.138]
DKS
3 02 ∅ 4,00 A
M3 [.118] ø 3,5 [.138] ø 4 [.157] ø s.tbl.
(.157)
HSS-150 ... M 3 03 A
Flying Probe
∅ 4,00
Bead Probe
(.157)
2 [.079] 3 [.118]
5,5 [.217]
3 05* S
43,1 [1.697] ∅ 4,00
(.157)
ø 4 [.157] ø 4,3 [.169]
Fine Pitch
3 06 A 3,00 (.118)
∅ 4,00
(.157)
KS-150 30 M3
1:1
0,3 [.012] 3 17 A
∅ 3,00
43 [1.693] (.118)
Stand. GKS
Metric
ø 4,05 [.159]
3 19 A
∅ 4,00
(.157)
KS-150 30 M3-R
* pressed-in silver stud
short / long
M3 [.118] ø 4 [.157] ø 4,05 [.159] ø 4,3 [.169]
HSS
KS-150 M3 M3-R
Robust HSS
Dipole HSS
44 [1.732]
SKS
Compatible GKS Electrical data Mechanical data
GKS-854 M (assembled in same receptacle) Current rating (at room temp.): max. 50 A Working stroke: 4,4 mm (.173)
Step Probes
(for short loads up to 80 A) Maximum stroke: 5,5 mm (.217)
GKS ... M
Ri typical: < 10 mW Spring force at work. stroke: 3,0 N (10.8oz)
Materials Alternative: 5,0 N (18.1oz);
Plunger: BeCu, gold-plated or silver stud 10 N (36oz) (“99” in order number)
Barrel: Brass, silver-plated Current Rating
T [°C]
Spring: Stainless steel, gold-plated HSS-150 306 400 A 3002 M
rotating GKS
100
Receptacle: Brass, gold-plated
VF / Non-
80
60
Spring Force Chart
40 Spring Force
Operating temperature 20 [N] Maximum
0 10 20 30 40 50 60 10 N
RF Test Probes
10,0
Dipole-GKS
Current [A]
Mounting hole size 8,0
20 Stroke [mm]
10
Recommended screw-in torque 0
0 20 40 60 80 100 120 140 160 180 200
Min. 10 cNm / Max. 20 cNm Surrounding Temperature [°C]
Assorted
GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm)
3 = BeCu S = Silver
Accessories
Test probe: H S S 1 5 0 3 0 6 4 0 0 A 3 0 0 2 M
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
3 05* ∅ 4,00 S
(.157)
SW5
M5 ø5 ø 5,6 ø 3,3 ø 4 3 06 A
∅ 5,00
(.197) (.197) (.220) (.130) (.157) (.197)
HSS-621 ... M * pressed-in silver stud
4 2 5,5 3
(.157) (.079) (.217) (.118)
43,1 (1.697)
Lötmulde
Solder Cup
KS-621 30 M5-R
0,3
44 (1.732) (.012)
HSS-621 M in KS-621: 40 cNm Current [A] HSS-621 306 500 A 5002 M 4,0
90
Cable at KS-621: 2 Nm 75
2,0
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm)
3 = BeCu S = Silver
Test probe: H S S 6 2 1 3 0 6 5 0 0 A 5 0 0 2 M
Receptacles: K S – 6 2 1 M 4 M 5 - R K S – 6 2 1 30 M 5 - R
Information
Grid:
Product
≥ 7,60 mm
≥ 300 Mil High Current Probe up to 100 A
Installation height with KS: 10,8 mm (.425) Screw-in Test Probe
Recommended stroke: 4,4 mm (.173)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
SW 6 3 05* ∅ 6,00 S
(.236) (.236)
Flying Probe
(.236)
Bead Probe
HSS-623 ... M
* pressed-in silver stud
8 2 5,5 3
(.315) (.079) (.217) (.118)
52,1 (2.051)
Fine Pitch
(.197) (.256) (.258) (.272)
KS-623 M4 M5-R
12 0,3
(.472) 58 (2.283) (.012)
Stand. GKS
1:1
Metric
Lötmulde
Solder Cup
KS-623 30 M5-R
0,3
58 (2.283) (.012)
short / long
HSS
Robust HSS
Dipole HSS
SKS
Materials Electrical data Mechanical data
Plunger: BeCu, gold-plated or silver stud Current rating (at room temp.): max. 100 A Working stroke: 4,4 mm (.173)
Step Probes
Barrel: Brass, silver-plated Ri typical: < 5 mW Maximum stroke: 5,5 mm (.217)
GKS ... M
Spring: Stainless steel Spring force at work. stroke: 7,0 N (25.2oz)
Receptacle: Brass, gold-plated Alternative: 10,0 N (36oz); 15,0 N (54oz)
Current Rating
T [°C] HSS-623 306 600 A 7002 M
100
Operating temperature
rotating GKS
VF / Non-
80
Standard: -100° up to +200° C 60 Spring Force Chart
40 Spring Force
[N] Maximum
Mounting hole size 20
(Room Temperature 21 °C) 20,0
Stroke
0 Working Stroke
for KS-623 xx M5-R 0 20 40 60 80 100 120 16,0 15 N
in CEM1 and FR4: Ø 6,50 - 6,52 mm
RF Test Probes
Current [A]
Dipole-GKS
40
20
0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
Assorted
GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm)
3 = BeCu S = Silver
Accessories
Test probe: H S S 6 2 3 3 0 6 6 0 0 A 7 0 0 2 M
Receptacles: K S – 6 2 3 M 5 M 5 - R K S – 6 2 3 30 M 5 - R
Tools
Material
Further versions
Plating
Tip style
M1,6 ø1,65 SW1,7 øs.Tb. ∅ ∅ (inch)
02
3 * ∅ 2,00 S
M1,6 ø1,65 SW1,7 ø1 øs.tbl. (.079)
11 2
(.063) 4,5(.065) 2
(.067) (.039)
HSS-827 ...
MM 19,5 3 06 A
∅ 2,00
(.079)
11 (.433) 2 4,5 2
* pressed-in silver stud
(.079) (.177) (.079) 1:1
19,5 (.768)
ø1,95 ø2 ø2,05 ø2,2
ø2 ø2,05 ø2,2
0,2
(.079) (.081) (.087)
16,5
KS-427 30 M-R
0,2
16,5 (.650) (.008)
in CEM1 and FR4: ∅ 2,00 - 2,02 mm Current [A] HSS-827 306 200 A 1502 M 2,0 1.5 N
24
(.0787 - .0795) 20
1,0
16 0,0
12 0,0 1,0 2,0 3,0 4,0
8 Stroke [mm]
Recommended screw-in torque 4
Min. 3 cNm / Max. 5 cNm 0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
3 = BeCu S = Silver
Test probe: H S S 8 2 7 3 0 6 2 0 0 A 1 5 0 2 M
K S – 4 2 7 3 0 M - R
Receptacle:
Information
Grid:
Product
≥ 4,0 mm
≥ 160 Mil High Current Probe up to 30 A
Installation height with KS: 7,4 mm (.291) Short-stroke Test Probes to Plug in and Screw in
Recommended stroke: 2,8 mm
ø2,65 ø 3(.110)
ø3,5 ø s. tbl. ø 1,5 ø2,65 ø3 ø1,8
(.104) (.118) (.138) (.059) (.104) (.118) (.071)
Standard
GKS
Mounting and functional dimensions Available tip styles
(.031) 0,8 (.079) 2 3,5 1,6
Material
(.083) 2,1 3,5 1,6 (.138) Further versions
Plating
(.063)Tip style
15,1 (.594)
HSS-520 (.138) (.063) ∅ ∅ (inch)
15,1(.594) 19,2(.756)
E-TYPE
ø 3 Type
ø1,8 0 Type 1
DKS
ø2,65 ø3 ø3,5 ø s. tbl. ø 1,5 ø2,65 3 06 ∅ 2,30 A 3,50 (.138)
(.104) (.118) (.138) (.059) (.104) (.118) (.071)
ø 2,65 ø3,5 ø s.tbl. ø 2,65 ø 3 ø3,5 ø s.tbl. (.091)
(.104) (.138) (.104) (.118) (.138)
Flying Probe
(.083) 2,1 3,5 1,6 (.031) 0,8
Bead Probe
(.138) (.063)
15,1 (.594) (.083) 2,1 3,5 1,6 1:1
(.138) (.063) (.138) (.083) 2,1 3,5 1,6
15,1(.594) 19,2(.756) (.063)
15,1(.594)
15,1(.594) (.138) (.063)
Type 0 Type 1 Type S Note:
Type Z
ø 2,65 ø3,5 ø s.tbl. ø 2,65 ø 3 ø3,5 ø s.tbl. Typ Version
ø2,08 ø3 ø 3,3
(.104) (.138) (.104) (.118) (.138) (.082) (.118) (.130)
0 End of Probe Barrel open; with
reduced collar Ø 3 mm
Fine Pitch
1 End of Probe Barrel with solder
(.083) 2,1 3,5 1,6
(.031) 0,8 0,2 terminal
M2 ø2,65 SW3 ø 3,2 ø s.tbl. 13,6 (.535)
(.083) 2,1 3,5 1,6 (.008)
15,1(.594)
(.138) (.063) (.079) (.104) (.118) (.126) M End of Probe Barrel with thread
15,1 (.594) (.138) (.063) KS-913 35
M2 for KS-913 35 M (-R)
Type S HSS-520 ... M Z
Type S End of Probe Barrel closed; can
Stand. GKS
ø 3,3 2 3,5 1,6 be soldered into PCB
Metric
ø2,08 ø3 (.079)
(.082) (.118) (.130) 17,1 (.673) (.138) (.063) Z End of Probe Barrel closed; can
HSS-520 ... M
be soldered into PCB;
M2 ø2,65 SW3 ø 3,2 ø s.tbl. Ø0,2
2 ø3 ø 3,3 with reduced collar Ø 3 mm
(.079) (.104)
13,6 (.535)
(.118) (.126) (.008)
(.079) (.118) (.130)
short / long
KS-913 35
HSS-520 ... M
HSS
KS-913 35 M Warning: Soldering the Probes de-
(.079) 2 3,5 1,6 0,2 (.008) mands great care. High temperatures
17,1 (.673) (.138) (.063)
13,6 (.535) must not reach the inside of the barrel,
because this could destroy the spring.
Ø2 ø3 ø 3,3
Robust HSS
Dipole HSS
Ø2 ø3 Ø3,05 ø 3,3 The Receptacle KS-913 35 can only
(.079) (.118) (.130)
(.079) (.118) (.120) (.130) 1:1 be combined with the Probe Types 0,
KS-913 35 M KS-913 35 M-R
S and Z.
0,2 (.008) The Receptacle KS-913 35 M can only
0,2 (.008)
13,6 (.535) be combined with the Probe Type M.
13,6 (.535)
SKS
Ø2 ø3 Ø3,05 ø 3,3
(.079) (.118) (.120) (.130)
Step Probes
GKS ... M
0,2 (.008)
GKS 913 M (screw-in version) Ri typical: < 20 mW Maximum stroke: 3,5 mm (.138)
13,6 (.535) Spring force at work. stroke: 1,5 N (5.4oz)
Materials Current Derating
Plunger: BeCu, gold-plated Current [A] HSS-520 306 230 A 1502 S
Barrel: Brass, gold-plated 36
30
Spring: Stainless steel, gold-plated
rotating GKS
VF / Non-
24
Receptacle: Brass, gold-plated 18
12 Spring Force Chart
6 Spring Force
0 [N] Maximum
Operating temperature 0 20 40 60 80 100 120 140 160 180 200 6,0
Stroke
Standard: -100° up to +200° C Surrounding Temperature [°C] Working Stroke RF Test Probes
5,0
Dipole-GKS
4,0
Mounting hole size 3,0
for KS-913 35 and KS-913 35 M Current Derating
Current [A] 2,0
HSS-520 306 230 A 1502 S 1.5 N
in CEM1 and FR4: ∅ 2,98 - 2,99 mm 36 1,0
(.1173 - .1177) 30
0,0
for KS-913 35 M-R 24
18
0,0 1,0 2,0 3,0
in CEM1 and FR4: ∅ 3,00 - 3,02 mm Stroke [mm]
PKS
PSK
12
(.1181 - .1189) 6
0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
Assorted
GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm) 1, 0, S, M, Z
3 = BeCu
Accessories
Test probe: H S S 5 2 0 3 0 6 2 3 0 A 1 5 0 2 M
Receptacles: K S – 9 1 3 3 5 K S – 9 1 3 3 5 M K S – 9 1 3 3 5 M - R
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
M3 x 0,25 ø 3,5 ø4 SW3,5 ø4
(.118 x .010) (.138) (.157) (.138) (.157)
3 02 A
∅ 4,00
(.157)
Ø3 ø 3,96 ø 4 ø 4,3
(.118) (.156) (.157) (.169)
KS-552 35 M
0,3
8,5 (.012)
(.335)
14,5
(.571)
Test probe: H S S 5 5 2 3 0 6 4 0 0 A 2 0 0 3 M
Receptacle: K S - 5 5 2 3 5 M
Information
Grid:
Product
≥ 5,08 mm
≥ 200 Mil High Current Probe up to 50 A
Installation height with KS: 13,8 mm (.543) Long-stroke Test Probes to Plug in and Screw in
Recommended stroke: 7,4 mm (.291)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
ø 2,5 [.098] ∅ ∅ (inch)
ø 3,5 [.138] ø 4 [.157] ø s.tbl.
E-TYPE
DKS
3 02 ∅ 4,00 A
HSS-150 ... H (.157)
2 [.079] 3 [.118]
8,5 [.335] 3 05* S
∅ 4,00
Flying Probe
Bead Probe
41,5 [1.634] (.157)
Fine Pitch
(.157)
40 [1.575]
Total length 46,1 mm (1.815), special designation “MH“
M3 [.118] ø 4 [.157] ø 4,05 [.159] ø 4,3 [.169]
* pressed-in silver stud
KS-150 M3-R
Stand. GKS
1:1
Metric
8 [.315] 0,3 [.012]
40 [1.575]
short / long
HSS
HSS-150 ... MH
2 [.079] 3 [.118]
8,5 [.335]
Robust HSS
Dipole HSS
46,1 [1.815]
KS-150 30 M3
0,3 [.012]
SKS
43 [1.693]
ø 4,05 [.159]
Step Probes
GKS ... M
M3 [.118] ø 4 [.157] ø 4,05 [.159] ø 4,3 [.169]
KS-150 M3 M3-R
rotating GKS
VF / Non-
44 [1.732]
Spring: Stainless steel Spring force at work. stroke: 3,0 N (10.8oz) (.1570 - .1571)
Receptacle: Brass, gold-plated Alternative: 5,0 N (18.1oz); for KS-150 30 M3
10 N (36oz) ("99" in order number) in CEM1 and FR4: ∅ 3,99 mm (.1571)
(.1575 - .1583)
Recommended screw-in torque
Min. 10 cNm / Max. 20 cNm
Assorted
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
GKS
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
5,9 7,6
33,3 3 06 ∅ 3,96 A
ø 3,16 ø 2,03 ø s. tbl. (.160)
(.124) (.080)
HSS-005 3 13 A
∅ 2,03
6,4 2,5 (.080)
ø 3,56 ø 3,7
(.140) (.146)
KS-005 30 G
5,9 7,6 1:1
(.232) 33,3 (1.311) (.299)
Ordering example Series Tip Tip style tip diameter Plating Spring force Collar height
material (1/100 mm) A = Gold (dN) (mm)
3 = BeCu
Test probe: H S S 0 0 5 3 0 6 3 9 6 A 3 0 0 0
Receptacle: K S – 0 0 5 3 0 G
Dipole HSS
Standard
GKS
High Current Clamps
Robust
Scale 1:2 (mm) HSS
E-TYPE
DKS
200
Flying Probe
Bead Probe
Dipol High Current Probes
180 Four-wire Clamp
Dipole high current probes (Kelvin probes) are used to per-
HSS-624 M 92
160 form four-wire measurements directly on the contact surface.
Fine Pitch
VK-541 93
In doing so, the voltage on the inner conductor and the cur-
140 rent on the outer conductor are measured. This High Current Clamp
enables precise resistance measurement on accumulators or (flat/round)
flat connector blades (the resistance of the measurement
Stand. GKS
120 cable is not part of the measurement). HKF-617 94
Metric
KK-541 95
100 Dipole high current probes either have a coaxial design with HKR-612 M 96
HKR-672 M 97
central inner conductor, or are four-wire clamps with galvanic
HKR-694 98
short / long
80 insulted spring clips.
HSS
Robust High Current
Probes
60
(probe/contact terminal)
Scale 1:2 (mm)
Robust HSS
Dipole HSS
40 HSS-2259 99
HSS-2513 99
HSS-2516 99
20 HSS-2526 99
200
10 HSS-2532 99
SKS
0
180
HKR-612 M
HKR-672 M
HSS-624 M
HSS-2259
HKR-694
HKF-617
KT-2259
VK-541
KK-541
-20
160
Step Probes
GKS ... M
-40
140
-60
120 Shown without KS
rotating GKS
VF / Non-
-80
100
-100 The high current clamp series HKR and HKF enable secure,
80
RF Test Probes
Dipole-GKS
-80
Tools
91
91
HSS 624 M Grid:
≥ 7,60 mm
Dipole Probe up to 100 A ≥ 300 Mil
Installation height with KS: 10,8 mm (.425)
Recommended stroke: 4,4 mm (.173)
SW6 SW6
(.236)
ø1,5 ø0,7 M5
ø1,5 ø0,7 ø5,8M5 ø6,4 ø5,8ø6 ø6,4 ø3,8 ø6
(.059) (.028) (.197) (.228) (.252) (.149) (.236)
SW6
* (.236)
ø1,5 * ø0,7 M5 ø5,8 ø6,4 ø6
(.059) 8 (.028) (.197)8 2 2
5,5(.228)3 (.252) 5,5 3
(.236)
17,7 17,7 (.315) (.079) (.217) (.118)
(.697)
61,8 61,8 (2.433)
2
HSS-624 ... M * Inner conductor8tip style 06, not exchangeable 5,5 3
ø1,7 ø1,7 17,7 (.315) (.079) (.217) (.118)
bohrung M5Lötbohrung ø6,5
M5 (.697) ø6,5 ø6,9
61,8 (2.433) ø6,9
Soldering (.197) (.256) (.272)
Hole .067
ø1,7
Lötbohrung M5 ø6,5 ø6,9
3,55 3,55
Soldering (.197) 0,3
(.256) 0,3
(.272)
(.140) (.012)
12,55 Hole .067 12,55 KS-624 M5 M5-RF
(.494)
58,55 58,55 (2.305)
3,55 0,3
(.140) (.012) Note:
12,55
(.494) 58,55 (2.305) 1:1 The new screw-in dipole probe
HSS-624 M is a market-driven deve-
lopment for simultaneously transfer-
ring high currents and carrying out a
voltage measurement directly on the
contact pads (4 pole measurement).
Cable at KS-624: 2 Nm 40
20
0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
3 = BeCu S = Silver
Information
Grid:
Product
≥ 3,50 mm
≥ 140 Mil Four-wire Clamp up to 10 A
Installation height with KS: 19,1 mm (.752)
Recommended stroke: 5,0 mm (.197)
Standard
GKS
Mounting and functional dimensions
E-TYPE
DKS
VK-541
7,6 [.299] 18,9 [.744]
2,8 [.110] 53,5 [2.106]
Flying Probe
Bead Probe
2,3 [.091]
Fine Pitch
0,5 - 0,8*
inner conductor [.020 -.031] *
Stand. GKS
Metric
ø 1,7 [.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
Note:
KS-465 M2,5-F The VK-541 is a four-wire version
4,2 [.165] 0,2 [.008] of the original KK-541 contact
short / long
38,1 [1.500] clamp. In addition to the reliable
HSS
ø 3,05 [.120]
contacting of flat connectors on the
outer surface, the VK-541 enables a
KS-465 M2,5-F-R four-wire measurement. Hence, the
voltage can be measured directly on
Robust HSS
Dipole HSS
the contacting area thus determining
the resistance.
SKS
tions i.e. vibrations, contamination,
1:1 and longer testing cycles.
Step Probes
Spring clip: BeCu, gold-plated Current rating (at room temp.) Min. length 3,5 mm (.138)
GKS ... M
Barrel: Brass, gold-plated - outer conductor: max. 10 A Thickness flat connector*: 0,5 - 0,8 mm
Receptacle: Brass, gold-plated - inner conductor: max. 1 A (.020 - .031)
Ri typical outer conductor: < 5 mW
Ri typical inner conductor: < 10 mW
rotating GKS
VF / Non-
Operating temperature Current Rating Mechanical data
T [°C] VK-541 T0510 1410 M 3S05 A
Standard: -100° up to +200° C 100 Min. immersion depth**: 3,5 mm (.138)
80 Max. immersion depth**: 6,5 mm (.256)
60
Mounting hole size 40 RF Test Probes
for KS-465 M2,5-F
Dipole-GKS
20
(Room Temperature 21 °C)
in CEM1 and FR4: ∅ 2,98 - 2,99 mm 0
0 5 10 15 20
(.1173 - .1177) Current [A]
for KS-465 M2,5 F-R: ∅ 3.00 - 3,02 mm
(.1181 - .1189) Current Derating
Current [A] VK-541 T0510 1410 M 3S05 A
15
Recommended Screw-in torque
PKS
PSK
10
VK-541 in KS-465: 3 cNm
5
0
0 20 40 60 80 100 120 140 160 180 200
Assorted
Ordering example
Accessories
Four-wire clamp: V K 5 4 1 T 0 5 1 0 1 4 1 0 M 3 S 0 5 A
4,6 [.181]
Current Derating
Current [A] HKF-617
50
HKF-617 063xx
40
30
HKF-617 032xx
20
10
0
0 20 40 60 80 100 120 140
Surrounding Temperature [°C]
Receptacle: K S - 6 1 7 3 5 - R
Information
Grid:
Product
≥ 3,50 mm
≥ 140 Mil Contact Clamp up to 20 A
Installation height with KS: 16,6 mm (.654) Clamp to Press-in and Screw-in
Recommended stroke: 5,0 mm (.197)
Standard
GKS
Mounting and functional dimensions
KK-541 to screw-in
E-TYPE
M2 [.079] ø 2,65 [.104] ø 4 [.157] 3,2 [.126] 2,2 [.087]
DKS
2,8 [.110] 3 [.118] 16,35 [.644]
Flying Probe
Bead Probe
34,35 [1.352]
KK-541 ... M2 3S05 A 2,3 [.091]
Fine Pitch
ø 3,05 [.120]
ø 3 [.118] ø 3,2 [.126]
1:1
KS-113 30 M2-R-S
Stand. GKS
Metric
0,2 [.008]
27 [1.063]
KK-541 to press-in
short / long
ø 2,2 [.087] solder cup ø 2,65 [.104]
HSS
5 [.197] Note:
Robust HSS
Dipole HSS
36,35 [1.431] The contact clamp KK-541 offers
KK-541 ... 30 3S05 A reliable contacting of flat connectors
0,5 - 0,8 *
[.020 - .031] * on the outer surface.
Even under harsh testing conditions
with flat connector
with vibrations, contamination,
1:1 and longer test cycles, the KK-541
SKS
6,5 (3,5) ** proves to be most suitable due to its
[.256] ([.138]) ** double spring clip design.
Step Probes
GKS ... M
Materials Electrical data Flat connector to be contacted
Spring clip: BeCu, gold-plated Current rating (at room temp.): max. 20 A Min. length: 3,5 mm (.138)
Barrel: Brass, gold-plated Ri typical: < 5 mW Thickness flat connector*: 0,5 - 0,8 mm
Receptacle: Brass, gold-plated (.020 - .031)
rotating GKS
VF / Non-
Current Rating
Operating temperature T [°C] KK-541 400 FC 1410 M2 3S05 A Mechanical data
Standard: -100° up to +200° C 100 Min. immersion depth**: 3,5 mm (.138)
80 Max. immersion depth**: 6,5 mm (.256)
60 Working stroke: 5,0 mm (.197)
Mounting hole size 40
for KS-113 30 M2-R-S
RF Test Probes
Dipole-GKS
20
(Room Temperature 21 °C)
in CEM1 and FR4: 3,00 - 3,02 mm
∅ 0
(.1181 - .1189) 0 10 20 30 40
Current [A]
for KK-541 to press-in: ∅ 2,64 mm (.1043) Current Derating
Current [A] KK-541 400 FC 1410 M2 3S05 A
25
20
PKS
PSK
15
10
Recommended tightening torque 5
KK-541 in KS-113: 10 cNm 0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
Assorted
GKS
Ordering example
Accessories
Receptacle: K S - 1 1 3 3 0 M 2 - R - S
Tools
contacting area
HKR-612 300 100 S 10003 M ø 6 0,2
(for 3 mm tip diameter) insulation part [.236 .008]*
ø 7 [.276] SW 8 [.315] ø 9,05 [.356]
M8 x 0,75
M3 [.118] [.315] x [.030] ø 6,4 [.252] ø 9 [.354] ø 9,6 [.378]
Information
Grid:
Product
≥ 18,00 mm
≥ 700 Mil High Current Clamps
Installation height with KS: 33,5 mm (.1.319) - 34,7 mm (1.366) for Round Post-∅ 8,0/10,0/12,0 mm
Recommended stroke: 4,0 mm (.157) respect. 4,4 mm (.173)
Standard
GKS
Mounting and functional dimensions
E-TYPE
DKS
ø 14,4 [.567] SW 14 [.551] ø 16 [.630] ø 16,05 [.632]
13 [.512] **
Flying Probe
KS-672 D08 M10-R
Bead Probe
Example of contacting with HKR-672 ... M, ∅ 12 mm
34,2 [1.346] 15 [.591] 0,5 [.020]
58,7 [2.311] 58 [2.283]
72,7 [2.862]
Note:
Fine Pitch
HKR-672 1000 130 S 20004 M
(for 10 mm tip diameter) The high current clamps HKR-672 M
enable the reliable contacting of
ø 16,4 [.646] SW 16 [.630] ø 18 [.709] ø 18,05 [.711]
M12 [.472] ø 19 [.748]
round posts and threads. When
M12 [.472] ø 15 [.591]
contacting, the contact lamellas are
Stand. GKS
pressed on the bolt without scrat-
Metric
KS-672 D10 M12-R ching it. The high current clamps are
especially recommended for round
34,2 [1.346] 15 [.591] 0,5 [.020]
contacts with contact protection,
58,7 [2.311] 58 [2.283]
which cannot be contacted from the
short / long
72,7 [2.862]
top.
HSS
HKR-672 1200 130 S 20004 M The HKR-672 M are also ideal for
(for 12 mm tip diameter)
harsh testing conditions with vibra-
ø 17,4 [.685] SW 17 [.669] ø 19 [748] ø 19,05 [.750] tions, contamination and longer
Robust HSS
testing cycles because of its robust
Dipole HSS
M12 [.472] ø 16 [.630] M12 [.472] ø 21 [.827]
design.
SKS
57,5 [2.264] 58 [2.283] round post-∅ and immersion depth
71,5 [2.815]
(round post lengths) upon request.
Step Probes
Plunger: BeCu, silver-plated Current rating (at room temp.): max. 200 A Min. immersion depth bolt: ** 13 mm (.512)
GKS ... M
Barrel: Brass, silver-plated Round post-Ø: * 8,0 mm ± 0,3 mm
Spring: Stainless steel (.315 ± .012)
Receptacle: Brass, silver-plated Current Rating 10,0 mm ± 0,3 mm
T [°C] HKR-672 (.394 ± .012)
Operating temperature 100 Ø8 12,0 mm ± 0,3 mm
rotating GKS
VF / Non-
Standard: -100° up to +200° C 80 Ø 10
(.472 ± .012)
60 Ø 12
Mounting hole size 40 Mechanical data
in CEM1 and FR4 20
(Room Temperature 21 °C)
Min. immersion depth bolt: ** 13,0 mm
for KS-672 D08 M10-R: ∅ 16,00 - 16,02 mm 0
0 40 80 120 160 200 240
(.512)
(.6299 - .6307) Working stroke
RF Test Probes
Current [A]
Dipole-GKS
for KS-672 D10 M12-R: ∅ 18,00 - 18,02 mm Current Derating HKR-672 800: 4,0 mm (.157)
(.7087 - .7094) Current [A] HKR-672 HKR-672 1000: 4,0 mm (.157)
Ø 12
for KS-672 D12 M12-R: ∅ 19,00 - 19,02 mm 240 HKR-672 1200: 4,4 mm (.173)
200 Ø 10
(.7480 - .7488) 160 Max. working stroke: 5,5 mm (.217)
Ø8
Recommended tightening torque 120 Spring force at work. stroke: 20 N (72oz)
80
HKR-672 M in KS-672: 2 Nm 40
PKS
PSK
Cable at HKR-672 M: 2 Nm 0
0 20 40 60 80 100 120 140 160 180 200
Surrounding Temperature [°C]
Receptacles: K S - 6 7 2 D 0 8 M 1 0 - R K S - 6 7 2 D 1 0 M 1 2 - R
K S - 6 7 2 D 1 2 M 1 2 - R
Tools
ø 4 [.157]
4,5 [.177] ø 3,5 [.138] ø 2,5 [.098] ø 6,8 [.268]
HKR-694
working stroke
56,2 [2.213]
4*
4,4
←
immersion depth
ø 4,75 [.187] insulation
SW 5 [.197] part
ø 4,7 [.185] ø 6 [.234]
8
KS-617 35-R
0,5 [.020]
50 [1.969]
Note:
The high current clamp HKR-694
was developed for plug connectors
with 4 mm nominal diameter which
are arranged in a small grid size.
Grid size of 5,5 mm is possible due
to the combination of lamellae and
slim base body.
Receptacle: K S - 6 1 7 3 5 - R
Information
Product
High Current Probe from 25 up to 400 A
Installation heights: see drawings below Reinforced / Robust HSS
Recommended stroke: 7,0 mm (.276)
Standard
GKS
Mounting and functional dimensions
ø6,5
ø4,9
(.256)
Electrical data
(.193) Current Rating
Max. current rating: 25 A
E-TYPE
SW7 ø9 M5
DKS
M5 ø9 SW7 ø4 T [°C] HSS-2259
(.275) (.354)
(.197) (.354) (.276)
ø4,9
(.157) ø6,5 (.197)
Ri typical: < 1 mW 80
(.256)
(.193) 60
SW7 ø9 M5
M5
(.197)
ø9
(.354)
SW7
(.276)
ø4,9
ø4 ø6,5
(.157) ø6,5(.275) (.354)
(.256) (.197)
Mechanical data 40
(.193)
20 (.787)
M5 ø9
28 (1.102) 9,5
ø4,9
SW7 (.374) ø4
27 (1.063)
SW7
(.256) ø9 M5 Working stroke: 7,0 mm (.276) 20
(.193)
(.197) (.354)57,5 (2.264)
(.276) (.157) SW7 (.275) 42 (1.654)
(.354) (.197) Maximum stroke: 9,5 mm (.374)
Flying Probe
ø9 M5
Bead Probe
M5 ø9 SW7 ø4 (Room Temperature 21 °C)
(.275) (.354) 0
(.197)
20 (.787) (.354)
HSS-2259 (test (.276) 9,5
probe)
28 (1.102) ø4,9(.157)
ø6,5
KT-2259 27 (contact
(.256)
(1.063)
(.197)
terminal) Spring force at work. stroke: 10 N (36oz) 0 5 10 15 20 25 30
(.193)
M5 ø957,5 (2.264)
SW7
(.374)ø7 (.276) SW7 42ø9(1.654) M5
ø4 Recommended tightening torque: 3 Nm Current [A]
27 (1.063)
20 (.787)
(.197) (.354) SW10 9,5 ø6
28 (1.102)
(.276) (.157) SW10(.275) (.354) (.197)
20 (.787) (.394) (.374)
28 (1.102)
57,5 (2.264) 9,5 (.236) 27 (1.063)
(.394) 42 (1.654)
ø12 ø13 (.374)ø7 (.276)ø9
M6 57,5 (2.264)
(.472) (.512)
ø12,9 42 ø11
(1.654) M6
Electrical data
(.236) SW10 ø6(.354) SW10 (.508) (.433) (.236) Current Rating
20 (.787) (.394) 9,5ø7(.236)
28 (1.102) 27 (1.063)
(.276) (.394) Max. current rating: 35 A T [°C]
Fine Pitch
HSS-2513
M6 ø12 ø13
57,5 (2.264)
SW10
(.374) ø9 SW10
ø7ø6(.276) ø12,942 (1.654) ø11 M6 Ri typical: < 1 mW 80
(.236) (.472) (.512)
(.394) (.354) (.394)
(.508) (.433) (.236)
27(1.063) SW10 10,5 (.236)
42 (1.654) ø6 8SW10 (.315) 60
M6 ø12 ø13
(.394) (.413)(.236)
79,5 (3.130)
(.472) (.512)
ø9 (.394)
ø12,9
42 (1.654)
ø11 M6 Mechanical data
(.236) ø12 (.354)
ø7 (.276) (.508) (.433) (.236) 40
M6
(.236) (.472)
ø13
(.512)
ø9
SW10 10,5 ø6(.354) 8SW10
ø12,9
(.508)
ø11
(.433)
69 (2.717)
M6
(.236)
Working stroke: 7,0 mm (.276)
27(1.063) 42 (1.654) (.315) 20
(.394) (.413)(.236) (.394) Maximum stroke: 10,5 mm (.413) 0
(Room Temperature 21 °C)
79,5 (3.130) 42 (1.654) ø11
M6 ø12 ø13 ø9 ø12,9 M6 Spring force at work. stroke: 12 N (43.2oz)
Stand. GKS
27(1.063) 42 (1.654) 10,5 8 (.315) 0 5 10 15 20 25 30 35 40
(.236) (.472) (.512) ø9 (.354)
(.354) (.508) (.433)
69 (2.717) (.236)
Metric
27(1.063) 42 (1.654)
79,5 (3.130)
SW12
(.413)
10,5
ø6
8 (.315)
SW12 42 (1.654) Recommended tightening torque: 4 Nm Current [A]
short / long
(.236) (.591) (.630) (.433) (.630)
(.472) (.551) (.236)
(.472)
SW12 (.236)
ø6 SW12 T [°C] HSS-2516
27 (1.063) 42,2 (1.661) 12 9 (.354)
M6 ø15 ø16 ø11 ø16 ø14 M6 Ri typical: < 1 mW
HSS
(.472) (.472) (.236) (.472) 80
(.236) (.591) (.630) ø9 (.433)
(.354)
ø11 (.630)
ø16 (.551) (.236)
M6 81,2 ø16
ø15 (3.197) 42 (1.654) ø14 M6
60
(.236)
27 (1.063)
(.591) (.630)
42,2
SW12
(1.661) 12
(.433) SW12
ø6
9
(.630)
(.354)69 (2.717)
(.551) (.236) Mechanical data
(.472) (.236) (.472) 40
M6 ø15
81,2 ø16(3.197)
(.472) ø11 ø1642 (1.654) ø14 M6 Working stroke: 7,0 mm (.276)
20
27 (1.063) (.591)
(.236) (1.661)
42,2 (.630) 12 (.433) 9 (.630)
(.472)
(.354)
69 (2.717)
(.551) (.236) Maximum stroke: 12 mm (.472) (Room Temperature 21 °C)
27 (1.063) 42,2 (1.661) 12 9 (.354) 0
81,2 (3.197)
SW20 ø16 42 (1.654) Spring force at work. stroke: 17 N (61.2oz)
Robust HSS
Dipole HSS
0 20 40 60 80 100
(.787) (.472)(.630)
ø25 81,2ø26 (3.197)
3x ø6
(1.654)
ø2042 69 (2.717) M8 Recommended tightening torque: 4 Nm Current [A]
M8
27 (1.063) (1.024)
(.984) 42,2 (1.661) 12 3x(.236) 9 (.787) (.354)69 (2.717) (.315)
HSS-2516
(.315)
(test probe)
SW20
(.472)
ø16KT-2516 (contact terminal)
(.787)
81,2 (3.197) (.630) 42 (1.654)
ø25 ø26 3x ø6 ø20 M8
M8 (.984) (1.024)SW20 ø16
3x(.236) (.787) 69 (2.717) (.315)
(.787) (.630)
(.315) ø25 ø26SW20 ø16
3x ø6 ø20 M8 Electrical data
M827 (.984) (.787) (.630) Current Rating
ø25 (1.024)(2.047)
52ø26 11 3x(.236) (.787) 8,5 28 (.315)
(1.063)
(.315)
M8 (.984) 90(1.024) (.433)
3x ø6 ø20
(.335) (1.102)
M8 Max. current rating: 200 A T [°C] HSS-2526
3x(.236) (.787) 75 (2.953) (.315)
SKS
(3.543)
(.315)
SW20
(.787)
ø16
(.630)
Ri typical: < 1 mW 80
27 ø25 52ø26 (2.047) 11 3x ø6 ø20 8,5 28 M8 60
(1.063)
M8 (.984) (1.024)
90 (3.543)
(.433) 3x(.236) (.787) (.335)
75 (2.953)
(1.102)(.315) Mechanical data 40
(.315)27 52 (2.047)ø25,911 8,5 28
(1.063) (1.020)
(.433) (.335) (1.102)
Working stroke: 7,0 mm (.276) 20
27 (2.047)
9052(3.543) 11 3x ø8 ø328,5 75 (2.953) 28 M14
(1.063)
M14
ø32
(1.260) (.433)3x(.315) (1.260) (.335)
ø32
(1.102) Maximum stroke: 11 mm (.433) (Room Temperature 21 °C)
Step Probes
(3.543) (1.260) (.551) 0
GKS ... M
90
(.551) ø25,9 75 (2.953)
Spring force at work. stroke: 58 N (208.8oz) 0 50 100 150 200
27 52 (2.047) (1.020)11
ø328,5(contact 28 M14
Recommended tightening torque: 11 Nm Current [A]
HSS-2526
(1.063)
(test probe)
ø32 3xKT-2526
ø8
(.335)
ø32terminal)
(1.102)
M14 (.433)3x(.315) (1.260)
(1.260)ø25,9 (1.260) (.551)
90 (3.543) 75 (2.953)
(.551) (1.020)
ø32 ø25,9 3x ø8 ø32 ø32 M14
M14
51 (2.010) (1.020)
(1.260) 3x(.315) ø32
(1.260) (1.260) (.551)
ø32(2.047) 11 3x ø8
52 52 (2.047) ø32 M14
(.551)
M14 (1.260) (.433) 3x(.315) (1.260) (1.260)
(3.996) (.551)
(.551)
114 (4.488) ø25,9 101,5
Electrical data
rotating GKS
(1.020) Current Rating
VF / Non-
51 (2.010)
M14
ø32(2.047) 11 3x ø8
52 ø3252 (2.047) ø32 M14 Max. current rating: 400 A T [°C] HSS-2532
(1.260) (.433) 3x(.315) (1.260) (1.260) (.551)
(.551) 114 (4.488)
51 (2.010) 52 (2.047) 11
101,5 (3.996) Ri typical: < 1 mW 80
52 (2.047)
60
51 (2.010) 52 (2.047)(.433)
114 (4.488) 11 52 (2.047)
101,5 (3.996)
(.433) Mechanical data 40
114 (4.488) 101,5 (3.996)
Working stroke: 7,0 mm (.276) 20
51 (2.010) 52 (2.047) 11 52 (2.047)
Maximum stroke: 11 mm (.433)
RF Test Probes
(Room Temperature 21 °C)
Dipole-GKS
(.433) 0
114 (4.488) 101,5 (3.996)
Spring force at work. stroke: 116 N (417.6oz) 0 100 200 300 400
Current [A]
HSS-2532 (test probe) KT-2532 (contact terminal) Recommended tightening torque: 59 Nm
The high current test probes
HSS-2259 to HSS-2532 are designed
Materials Operating temperature for applications with high permanent
PKS
PSK
Plunger: Brass, silver-plated Standard: +1° up to +80° C currents. Their robust construction
silver plating on the contact surface makes them equally suitable for harsh
Barrel: Brass, silver-plated
environmental and possible side loads.
Spring: Stainless steel
Assorted
GKS
Ordering example
Accessories
Test probe: H S S - 2 2 5 9 H S S - 2 5 1 3 H S S - 2 5 1 6 H S S - 2 5 2 6 H S S - 2 5 3 2
Contact terminal: K T - 2 2 5 9 K T - 2 5 1 3 K T - 2 5 1 6 K T - 2 5 2 6 K T - 2 5 3 2
Tools
Switching Probes
Switching probes are suitable for many various applications: Press-in and screw-in versions are available, depending
not only can they be used for component detection tests on installation requirements. These are also available as
and switches for closed/open checks, but also as a signal quick-exchange systems in most series. Screw-in versions
trigger for process control. Furthermore, in combination with are especially suitable for applications with vibrations or
other test probes (e.g., push-back probes), position determi- unwanted side forces or axial forces. This prevents the test
nation of contact terminals in plug housings is possible. probe moving out of the receptacle.
In most cases, INGUN switching probes are so-called “clos- The electrical connection is made either by directly soldering
ers”, and are normally opened (NO). That means that the on the receptacle (KS) and switching probe (SKS), using a
electric circuit is closed when the plunger is activated, plug, or a quick-exchange receptacle.
allowing the plunger to be pushed further beyond the
switching point. The rated current applied can only be
transmitted in the closed state.
Component detection test, load free detec- PCB presence check, Plug detection test in module &
tion with plastic tips fixture open/close check locking clip detection test at plug
4.0 mm to 10.0 mm
Type of ≥ 1.91 mm ≥ 2.54 mm ≥ 3.50 mm
Type of receptacle (160 Mil to 400
installion (≥ 75 Mil) (≥ 100 Mil) (≥ 140 Mil)
Mil)
SKS-415 2
Pressed SKS-100 SKS-419
Standard KS SKS-075 SKS-415 E
into SKS-215 € SKS-429
SKS-425
receptacle
Quick-exchange KS - SKS-215 E SKS-415 02 E -
SKS-465 MF
Standard KS - SKS-215 M SKS-435 M
Screwed SKS-465 SF
into SKS-463 MF
receptacle Quick-exchange KS - SKS-215 MF SKS-465 MF SKS-115 M
SKS-465 SF
Page(s) 103 104 - 105 / 109 106 - 107 / 110 - 112 108 / 113 - 114
100
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Switching Probes
Fine Pitch
SKS-075 103
these probes act as a closer and are normally open (NO). SKS-100 104
However, there are also openers, which are opened when SKS-215 (E*) 105
the switching circuit is activated. These switches are nor- SKS-415 (E*) 106
mally closed (NC). SKS-425 107
Stand. GKS
The switching probes vary in terms of the following SKS-419 108
Metric
features: dimensions (grid size and length), switch path, SKS-429 108
working stroke, installation method (press-in or screw-in),
Screw-in Probes
and available tip styles.
short / long
With insulating plastic tip styles, voltage-free checks can
SKS-215 M/MF* 109
HSS
be performed on components (here the signal is not sent SKS-465 MF* 110
through to the connection). SKS-463 MF* 111
SKS-465 SF* 112
To regulate the installation height, various receptacle collar SKS-115 M* 113
Robust HSS
Dipole HSS
heights are available. Similarly, screw-in versions vary the SKS-435 M 114
Scale 1:2 (mm)
installation height by means of a thread and allow the position
of the switch point to be precisely set. The switching probes Pneumatic PSK
are held in place by the crimp points on the receptacle.
PSK-350 M 173
200
SKS
Switching probes are installed either by pressing or screw-
180 ing them into the receptacle, for which both standard
* SKS with quick exchange system
receptacles and quick-exchange systems are available.
Step Probes
GKS ... M
160 The latter enables the switching probes to be changed
quickly without new wiring. This results in reduced main-
140 tenance and less down time, and thus the costs associated
with those. The wiring is done by the test equipment manufac-
rotating GKS
VF / Non-
120 turer only, thus preventing wiring errors during maintenance.
The quick-exchange receptacles are also available with a knurl
to ensure they are held securely in the bore hole over time.
100 RF Test Probes
Dipole-GKS
40
Scale 1:2 (mm)
20
Assorted
10
GKS
200 POS-NR.
POS-NR.
POS-NR.
POS-NR.
BENENNUNG
BENENNUNG
BENENNUNG
BENENNUNG BESCHREIBUNG
BESCHREIBUNG
BESCHREIBUNG
BESCHREIBUNG
MENGE
MENGE
MENGE
MENGE
0 1 1 Millimetereinteilung
Millimetereinteilung
1Katalog Millimetereinteilung
1KatalogMillimetereinteilung 1 1 1 1
Katalog Katalog
2 2 2SKS-075
SKS-075
SKS-075
306306
A22000
130
SKS-075
130
306
A A 130
306
A 130 A 1 1 1 1
SKS-465 MF
SKS-463 MF
2000
2000 Katalog
A Katalog
A2000
Katalog
A Katalog
SKS-465 SF
PSK-350 M
SKS-215 M
SKS-115 M
SKS-435 M
3 3 SKS-100
SKS-100
32000 SKS-100
306306
100
SKS-100
100
306
A A 100
306
A 100 A
A32000
2000 Katalog
A Katalog
A2000
Katalog
A Katalog 1 1 1 1
SKS-075
SKS-100
SKS-215
SKS-415
SKS-425
SKS-419
SKS-429
4 4 SKS-215
SKS-215
41502 SKS-215
002002
180
SKS-215
180
002
A A 180
002
A 180 A
E4Katalog
1502 1502
E Katalog
E1502
Katalog
E Katalog 1 1 1 1
180 5 5 5SKS-415
SKS-415
2302
SKS-415
302302
E5Katalog
2302 2302
300
SKS-415
300
302
E Katalog
A A
E2302
300
Katalog
302
A 300 A
E Katalog 1 1 1 1
-20 6 6 SKS-425
SKS-425
62502 SKS-425
002002
E6Katalog
2502 2502
300
SKS-425
300
002
E Katalog
A A
E2502
300
Katalog
002
A 300 A
E Katalog 1 1 1 1 POS-NR.
1
POS-NR.
POS-NR.
BENENNUNG
POS-NR.
BENENNUNG
POS-NR.
BENENNUNG
POS-NR.
BENENNUNG
1 Milimetereinteilung
BENENNUNG
1Milimetereinteilung
BENENNUNG
1Milimetereinteilung
1Milimetereinteilung
Milimetereinteilung
1 Milimetereinteilung
POS-NR. BENENNUNG BESCHREIBUNG MENGE
Accessories
Katalog
Katalog Katalog KatalogKatalog Katalog
7 7 7SKS-419
SKS-419
6508
6508 7SKS-419
005005
Katalog
6508
300
SKS-419
Katalog
300
005
A A
Katalog
300
005
A 300 A
6508 Katalog 1 1 1 1 Millimetereinteilung
2 SKS-215
2 1502 SKS-215
2M 3022SKS-215
180
302A180SKS-215
302
A 180
SKS-215
302
A 180SKS-215
302
A 180302
A 180 A 1 1
1502
Katalog
M1502 M21502
Katalog 2Katalog
Katalog
M1502 M 1502
Katalog
M Katalog Katalog
8 8 8SKS-429
SKS-429
8SKS-429
005005
500
SKS-429
500
005
A A 500
005
A 500 A 1 1 1 1 SKS-465
SKS-465
3063SKS-465
230
306A230SKS-465
306
A 230
SKS-465 PSK-350 204 130 R
8008
8008
Katalog
8008
Katalog
Katalog
8008 Katalog 3 3 2002 3MF
2002Katalog
MF 2002 32002
Katalog
MF 3306
Katalog
MF
A 230
2002
SKS-465
Katalog
306
MF2002
A 230306
Katalog
A 230 A
MF Katalog
2 0602 M-6 Katalog 1
4 SKS-463
SKS-463
3064SKS-463
230
306A230SKS-463
306
A 230
SKS-463
306
A 230SKS-463
306
A 230306
A 230 A
Note:
4 4 4 4
160
2202 MF
2202Katalog
MF 2202
Katalog
MF 2202
Katalog
MF2202
Katalog
MF2202
Katalog
MF Katalog
5 SKS-465
SKS-465
5 2002 5SF 302 SKS-465
300
302A300SKS-465
302
A 300
SKS-465
302
A 300SKS-465
302
A 300 302
A 300 A
2002 SF52002
Katalog SF52002
Katalog 5Katalog
Katalog
SF2002 SF 2002
Katalog
SF Katalog
-40 6 SKS-115
SKS-115
6 1502 6M 306 SKS-115
200
306A200SKS-115
306
A 200
SKS-115
306
A 200SKS-115
306
A 200 306
A 200 A
M61502 M61502 6Katalog
101
120 101
-80
Technical Information
Switching Probes
Overview and Comparison
Installation
Max. Spring forces
Grid Working Switch height with Shortest
SKS probe stro- Current at working
Series size stroke path receptacle probe Page
version ke rating (A) stroke (N)
(≥ mm) (mm) (mm) (mm) (mm)
(mm)
min max min max
SKS-075 1.91 4 5 2.6 1 2 - 9,1 - 30 103
SKS-100 2.54 5 6 4 3 2 - 16,4 19,1 43,4 104
SKS-215 (E*) 2.54 4 5 1.5 3 0,8 3 10,2 - 44,6 105
Press-in
SKS-415 (E*) 3.5 4 5.2 1.7 5 2,3 - 10,4 24,9 42,3 106
probes
SKS-425 3.5 6.4 8 2.4 5 2,5 - 13,2 - 57,9 107
SKS-419 7.5 11.2 14 2 5 5,2 - 27,4 - 73,8 108
SKS-429 10 12.8 16 2 5 6,4 - 27,4 - 80,8 108
SKS-215 M/MF* 2.54 4 5 1.5 3 0,8 3 10,2 20 46,5 109
SKS-465 MF* 3.5 4.2 5.2 1.7 3 2 9 10,4 26,7 44,8 110
Screw-in SKS-463 MF* 3.5 4 5 1.7 3 2,2 10,4 26,7 44,8 111
probes SKS-465 SF* 3.5 4.2 4.5 1.7 3 2 9 10,4 26,7 44,8 112
SKS-115 M* 4 4 5 1.7 3 1,5 3 9,2 - 25,2 113
SKS-435 M 4.5 7 8 6 3 15,6 26,9 20,8 - 83,9 114
Pneumatic PSK PSK-350 M 3.5 6 10 6 1–2 0,6 - 5,7 - 36,2 173
* SKS with quick exchange system
Advantages
– One-time wiring of the receptacle at the time
of customising the test fixture or unit
– Insertion of the SKS from above
(test fixture need not be opened)
– Reduction of the maintenance costs
– No wiring faults as a result of maintenance
+ + +
_ _ _
102
SKS 075
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil Switching Probe
Installation height with KS: 9,1 mm (.279) / variable Closing version (NO)
Recommended stroke: 2,6 mm (.102)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
ø 0,38 [.015] ø 1 [.039] ø 0,64 [.025] ø s.tbl.
DKS
solder connection 3 02 A
∅ 0,80
(.031)
SKS-075
2,5 [.098] 5,2 [.205] 1,3 [.051] 3 06 A
∅ 1,30
30 [1.181] (.051)
Flying Probe
Bead Probe
ø 1,32 [.052] ø 1,45 [.057]
KS-075 35 K
1,5 [.059]
Fine Pitch
19,5 [.768]
Stand. GKS
Metric
short / long
HSS
9,1 [.358]
Robust HSS
Dipole HSS
Collar height and installation height
To adjust the installation height receptacles
SKS
with a press-ring are used. The receptacles
can be inserted up to the press-ring or with the
press-ring pressed into the mounting hole.
Step Probes
GKS ... M
SKS-075 in
KS-075 35 K
rotating GKS
VF / Non-
Maximum stroke: 5,0 mm (.197) Spring: Steel, gold-plated points of the receptacle.
Receptacle: Nickel-silver, gold-plated
Contact terminal: Brass, gold-plated
Spring force at switch. point: 1,1 N (3.6oz) Insulator: Peek
Spring force at work. stroke: 2,0 N (7.2oz)
RF Test Probes
Dipole-GKS
Ordering example
GKS
Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold at working (mm)
3 = BeCu stroke (dN)
Accessories
Test probe: S K S 0 7 5 3 0 6 1 3 0 A 2 0 0 0 A
Receptacle: K S – 0 7 5 3 5 K
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
solder connection
ø 0,35 ø 0,5 ø 0,8 ø 1,37 ø 0,85 øs. tbl. ∅ 1,30 A
0 02
(.014) (.020) (.031) (.054) (.033) (.051)
solder connection
ø 1,37 (.054) (.033) ø 0,85 ø 1 ø 0,73 3 52 ∅ 0,73 A
(.039) (.029) (.029)
0,3 (.012)
9,8 (.386) 25 (.984) 6,1 5,3
(.240) (.209)
46,1 (1.815)
SKS-100 352 073 A 2000 A
19,1 (.752)
16,4(.646)
7,6
16,4
(.299)
30 (1.181)
KS-100 35 G
Test probe: S K S 1 0 0 3 0 6 1 0 0 A 2 0 0 0 A
Receptacle: K S – 1 0 0 3 5 G
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Switching Probe
Installation height with KS: 10,2 mm (.402) Closing version (NO)
Switch path: 1,5 mm (.059)
solder or plug connection (SE-215) ø 2 [.079]
Standard
ø 0,7 [.028] ø 1,65 [.065] ø 1 [.039] ø s.tbl.
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
SKS-215
5,5 [.217] switching path 1,5
solder or plug connection (SE-215)
2 [.079] 5 [.197]
ø 2 [.079]
3 [.118] Tip style
∅ ∅ (inch)
44,6 [1.756]
ø 0,7 [.028] ø 1,65 [.065] ø 1 [.039] ø s.tbl.
E-TYPE
DKS
ø 1,2 [.047] ø 2 [.079] ø 2 [.079] ø 2 [.079] ø 2,2 [.087] 0 02 ∅ 1,80 A
(.071)
Flying Probe
Bead Probe
13 [.512] 27,2 [1.071]
ø 1,2 [.047] ø 2 [.079] ø 2 [.079] ø 2 [.079] ø 2,2 [.087]
SE-215 for KS-215 3 03 ∅ 1,80 A
usage with SKS-215 (.071)
Fine Pitch
SE-215 for
ø 0,5 [.020] KS-215
3 05 ∅ 1,00 A
usage with SKS-215 (.039)
1,50 (.059)
SKS-215 ... 6,5
E [.256] 3 06 ∅ 1,80 N 2,00 (.079)
switching path 1,5 (.071) 2,30 (.091)
solder and plug connection (SE-415)
Stand. GKS
45,6 [1.795]
ø 0,5 [.020]
Metric
3 19 ∅ 1,80 A
ø 0,4 [.016] ø 1,2 [.047] ø 1,4 [.055] ø 2 [.079] ø 2,2 [.087]
(.071)
short / long
12,5 [.492] 27,2 [1.071]
ø 2 [.079] ø 2,2 [.087]
Collar height and installation height
HSS
ø 0,4 [.016] ø 1,2 [.047] ø 1,4 [.055]
SE-415 for KS-215
The installation height of the tip (dimensi-
usage with SKS-215 ... E on without KS) is determined by the collar
height.
2,5 [.098] solder and7,5 [.295]
plug connection 0,2 [.008]
ø 12,5
0,5 [.020]
[.492] 27,2 [1.071] Collar height Installation height
Robust HSS
Dipole HSS
SE-415 for KS-215 without receptacle
usage with SKS-215 ... E 02 10,0 mm (.394)
6,5 [.256] switching path 1,5
solder and plug connection
Quick-exchange system for SKS-21545,6 ... [1.795]
E
ø 0,5 [.020]
ø 0,4 [.016] ø 1,2 [.047] ø 2 [.079] ø 2,2 [.087] Warning:
Do not solder the cable to the crimp
SKS
points of the receptacle.
6,5 [.256] switching path 1,5
2,5 [.098] 45,6 [1.795] 0,2 [.008] The KS-215 S receptacle enables easy
10,2 (.402)
Step Probes
43 [1.692]
GKS ... M
2,2 (.087)
rotating GKS
VF / Non-
KS-215 S for with KS
usage with SKS-215 ... E
shown on page 109.
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
GKS
Test probe: S K S 2 1 5 3 0 2 1 8 0 A 3 0 0 2
Receptacle: K S – 2 1 5 K S – 2 1 5 S
Lamellar plug: S E – 2 1 5 S E – 4 1 5
Tools
Material
plug connection Further versions
Plating
plug connection
plug connection ø 3ø [.118]
3 [.118] ø 1,8 [.071]
ø 1,8 [.071] Tip style
ø 0,5
ø 0,5 ø 3 [.118] ø 1,8 [.071] ∅ ∅ (inch)
ø 0,5
[.020]
[.020] ø 2,65 [.104]
ø 2,65 [.104] ø s.tbl.
ø s.tbl.
[.020] ø 2,65 [.104] ø s.tbl.
5,00 (.197)
SKS-415 ... ...
SKS-415 22 0 02 A 2,30
SKS-415 ... 2 (.091)
∅ 3,00
5,55,5
[.217]
[.217] 2 [.079]
2 [.079] 3 [.118]
3 [.118] (.118)
5,5 [.217] 2 [.079] 3 [.118]
switching
switching path 1,71,7
path [.067]
[.067] 5,25,2
[.205]
[.205]
switching path 1,7 [.067] 5,2 [.205] 3 02 ∅ 1,80 A
42,3
42,3[1.665]
[1.665] (.071)
42,3 [1.665]
ø 3ø [.118]
3 [.118] ø 3,2 [.126]
ø 3,2 [.126]
ø 0,4 [.016]
ø 0,4 [.016] ø 1,2 [.047]
ø 1,2 [.047] ø 1,4 [.055]
ø 1,4 [.055] ø 3 [.118] ø 3,2 [.126]
ø 0,4 [.016] ø 1,2 [.047] ø 1,4 [.055] 3 02 ∅ 3,00 A
(.118)
2,52,5
[,098]
[,098] 7,57,5
[.295]
[.295] 0,20,2
[.008]
[.008] 3 03 ∅ 2,30 A
2,5 [,098] 7,5 [.295] 0,2 [.008]
12,5 [.492] 2323
[.906] (.091)
12,5 [.492] [.906]
12,5 [.492] 23 [.906]
SE-415
SE-415 forfor
SKS-415...2
SKS-415...2 KS-113
KS-1132323 ø2,3 0,4
SE-415 for SKS-415...2 KS-113 23
plug connection
plug connection 3 06 ∅ 1,00 A
plug connection (.039)
ø 1ø [.039]
1 [.039]
ø 1 [.039]
SKS-415 ... ...
SKS-415 EE
SKS-415 ... E
3 06 ∅ 1,05 A
6,56,5
[.256]
[.256] 4,6 (.040)
6,5 [.256]
43,3 [1.705]
43,3 [1.705]
43,3 [1.705]
ø 1ø [.039] 3 06 ∅ 2,30 A 4,00 (.157)
ø 1,7 [.067]
ø 1,7 [.067] 1 [.039]
ø 1,7 [.067] ø 1 [.039] (.091)
ø 1,2 [.047]
ø 1,2 [.047] ø 2ø [.079]
2 [.079] ø 2ø [.079]
2 [.079] ø 3ø [.118]
3 [.118] ø 3,2 [.126]
ø 3,2 [.126]
ø 1,2 [.047] ø 2 [.079] ø 2 [.079] ø 3 [.118] ø 3,2 [.126]
3 19 ∅ 2,30 A
(.091)
3 [.118]
3 [.118] 2,42,4
[.094]
[.094] 0,20,2
[.008]
3 [.118] 2,4 [.094] [.008]
0,2 [.008] 3 53* ∅ 2,30 A
10,2 [.402]
10,2 [.402] 9,49,4
[.370]
[.370] 2323
[.906]
[.906]
10,2 [.402] 9,4 [.370] 23 [.906] (.091)
SE-415 KSKS
SE-415 SE-502
SE-502 KS-113
KS-1132323
SE-415 KS SE-502 KS-113 23
forfor
SKS-415...E
SKS-415...E ø2,3 0,4
for SKS-415...E
Quick-exchange
Quick-exchange system
system with
with plug connection
plug connection 3 56* ∅ 1,00 A
Quick-exchange system with plug connection (.039)
SKS-415
SKS-415 EE ø 1ø [.039]
1 [.039]
SKS-415 E ø 1 [.039]
(only Collar
(only height
Collar 02)02)
height
(only Collar height 02)
3 56* ∅ 1,80 A
6,56,5
[.256]
[.256] (.071)
6,5 [.256]
43,3 [1.705]
43,3 [1.705]
43,3 [1.705]
3 56* ∅ 2,30 A
ø 1,2 [.047]
ø 1,2 [.047] ø 1,7 [.067]
ø 1,7 [.067] ø 3ø [.118]
3 [.118] ø 3,2 [.126]
ø 3,2 [.126] (.091)
ø 1,2 [.047] ø 1,7 [.067] ø 3 [.118] ø 3,2 [.126]
KS-415
KS-415SS * Tip length 9,5 mm (.374)
KS-415 S Total length 6,5 mm (.256) longer than standard tip styles
forfor
SKS-415 ... ...
SKS-415 0202
EE
for SKS-415 ... 02 E
4,64,6
[.181]
[.181] 0,20,2
[.008]
[.008]
4,6 [.181] 0,2 [.008]
39,6 [1.559]
39,6 [1.559]
39,6 [1.559] Mounting hole size
with receptacle: ∅ 2,98 - 2,99 mm
10,4 (.409)
Test probe: S K S 4 1 5 3 0 6 2 3 0 A 2 3 0 2 2
Receptacle: K S – 1 1 3 2 3 K S – 4 1 5 S
Lamellar plugs: S E – 4 1 5 S E – 5 0 2 S E – 4 1 5 K S
Information
Grid:
Product
connection for plug SE-415 ≥ 3,50 mm
ø 0,5 ≥ 140 Mil ø 1,8 [.071] Switching Probe with Long Stroke
Installation
[.020] height with KS: 13,2
ø 2,65 mmø(.520)
[.104] 3 [.118] ø s.tbl. Closing version (NO)
Switch path: 2,4 mm (.094)
Standard
SKS-425 ... B
GKS
Mounting and functional dimensions Available tip styles
5,6 [.220] switching path 2,4 [.094] 2 [.079] 8 [.315] 3 [.118]
57,9 [2.279]
Material
Further versions
Plating
Tip style
connection for plug SE-415 ∅ ∅ (inch)
E-TYPE
DKS
[.020] ø 1 [.039] ø 2,65 [.104] ø 3 [.118] ø s.tbl. 0 02 ∅ 3,00 A 5,00 (.197)
(.118)
plug connection
SKS-425 ... E
SKS-425 ø 3 [.118] ø 1,8 [.071]
ø 0,5... B
3 04 ∅ 2,30 A
[.020] ø 2,65 [.104] ø s.tbl.
(.091)
Flying Probe
5,6 [.220] 5,6 [.220]
switching path 2,4 [.094] 2 [.079] 8 [.315] 3 [.118]
Bead Probe
57,9 [2.279]
SKS-415 ... 2 57,9 [2.279] 3 06 ∅ 2,30 A 4,00 (.157)
SE-415 for usage connection
connection
with for plugfor
SKS-425 ...plug
B SE-415
SE-415 SE-502 for usage with SKS-425 ... E (.091)
5,5 [.217] 2 [.079] 3 [.118] ø 1,8 [.071]
plug 0,5 øø1,4
øconnection 0,5 ø1 ø 3 [.118] ø 1,8 [.071]
ø0,4 ø1,2
switching path 1,7 [.067]
ø2
5,2 [.205] ø 3,2 [.126]
(.016) (.047) [.020] [.020]
ø 1 [.039] (.055) ø 2,65 ø 2,65
[.104]
(.039) [.104]
ø 3 ø
[.118]
(.079) 3 [.118] ø s.tbl.ø s.tbl.
42,3 [1.665]
KS-113 23
Fine Pitch
SKS-425
SKS-425 SKS-425
...
E B[.047]... B ø 3,2 [.126]
ø 0,4 [.016] ø...1,2 ø 1,47,5 (.295)
[.055] ø 3(.098)
[.118]2,5
0,2 [.008]
12,5 (.492) 9,5 (.374)
5,6 [.220] 5,6 [.220] switching
switching path
path 2,4 2,4 [.094]
[.094] 2 [.079]2 [.079] 8 [.315]8 [.315] 3 [.118]3 [.118]
23 [.906]
5,6 [.220]
SE-415 for use with 57,9
57,9[2.279]
57,9 [2.279]
[2.279]
2,5 [,098] 7,5 [.295]
SKS-425 ... B 0,2 [.008]
12,5 [.492] 23 [.906]
Stand. GKS
plug connection
plug connectionKS-113 23
Metric
SE-415 for SKS-415...2 ø 3 [.118] ø 3,2 [.126]
ø 1 [.039]
ø 1 [.039]
plug connection
ø 1 [.039] KS-113 23
SKS-425 SKS-425
... E ... E
SKS-415 ... E
0,2 [.008]
short / long
6,5 [.256] 5,6 [.220]5,6 [.220] 23 [.906]
57,9 [2.279]
57,9 [2.279]
HSS
43,3 [1.705]
Robust HSS
Dipole HSS
KS-113KS-113
23 23
3 [.118] 2,4 [.094] 0,2 [.008] 0,2 [.008]
0,2 [.008]
10,2 [.402] 9,4 [.370] 23 [.906]
23 [.906]
23 [.906]
SE-415 KS SE-502 KS-113 23
for SKS-415...E
13,2 (.520)
SKS-425 ... E
15 E ø 1 [.039] The installation height of the tip (dimensi-
SKS
ollar height 02)
on without KS) is determined by the collar
ø2,7 ø3,2
6,5 [.256] ø2,7 ø3,2 height.
(.106) (.126) (.106) (.126)
43,3 [1.705]
Collar Installation height
Step Probes
GKS ... M
[.047] ø21,7 [.067] 1 ø 3 [.118] ø 3,2 [.126]
2 (.079) 3 (.118) 5 (.197) height without receptacle
(.079) (.039)
DS-113-01 DS-113 02 DS-113 03KS-415 S DS-113 05 with KS 02 13,0 mm (.512)
for SKS-415 ... 02 E
4,6 [.181] 0,2 [.008]
39,6 [1.559]
Mechanical data Materials
rotating GKS
VF / Non-
Switch path: 2,4 mm (.094) + 0,2 (.008) Plunger: BeCu, gold-plated Note:
Recomm. working stroke: 6,4 mm (.252) (or gold-plated with insulator cap) The receptacle can be used from grid
Maximum stroke: 8,0 mm (.315) Barrel: Brass, gold-plated size 4,5 mm (180 Mil) upward.
Spring force at switch.point: 0,9 N (3.2oz) Spring: Steel, gold-plated
Spring force at working stroke: 2,5 N Receptacle: Brass, gold-plated
RF Test Probes
Dipole-GKS
Test probe: S K S 4 2 5 3 0 4 2 3 0 A 2 5 0 2 B
Receptacle: K S – 1 1 3 2 3
Accessories
Spacers: D S – 1 1 3 0 2 D S – 1 1 3 0 3 D S – 1 1 3 0 5
Lamellar plugs: S E – 4 1 5 S E – 5 0 2
Tools
Delrin
15,7 2 7 8 8 16,1 3 35
SKS-429 switching
0,276 path2 0,3150,315
0,6180,079 0,118
0,634 0,197
0,118
2 0,079
7 8 3 5
15,70,079 80,8 path2 0,315 8
0,276 16,1
0,118 3Delrin
0,197
switching
SKS-429 0,618 3,181 0,315 0,634 0,118
0,079 Delrin
SKS-429 15,7 80,8 8 16,1 3
switching
3,181path2
0,618 0,315 0,634 0,118
15,7 0,079 8 16,1 3
switching 8
80,8 path2 8,5
0,618 0,315 0,634 0,118
0,315
0,079
3,181 0,335
80,8 8 8,5
3,181
0,315 0,335
KS-429 23
8 7,7 8,5
0,3
KS-429 23 57 0,315 0,303 0,335
8 0,012
8,5
2,244
0,315 7,7 0,335
0,3
57 0,303
KS-429 23 2,244 SKS 419 0,012 SKS 429
Mechanical
KS-429 23 data Mechanical
7,7
0,3
data
Switch path: 2,0 mm (.079) 57 + 0,2 (.008) 0,303
Switch path: 2,0 mm (.079) + 0,2 (.008)
0,012
2,244 7,7
Working Stroke: 11,0
57
mm (.433) Working
0,303 0,3 stroke: 12,8 mm (.504)
Maximum stroke: 14,0 mm (.551) Maximum
2,244
0,012 stroke: 16,0 mm (.630)
Spring force at switch.point: 2,6 N (9.4oz) Spring force at switch.point: 2,9N (10.5oz)
Spring force 80% stroke: 5,2 N (18.8oz) Spring force 80% stroke: 6,4 N (23.2oz)
Spring force max. stroke: 6,5 N (26.0oz) Spring force max. stroke: 8,0 N (31.0oz)
Electrical data Electrical data
Current rating: 5 A Current rating: 5A
(see page 100) (see page 100)
Materials Materials
Plunger: BeCu, gold-plated Plunger: BeCu, gold-plated
with insulator cap (Delrin) with insulator cap (Delrin)
Barrel: Brass, gold-plated Barrel: Brass, gold-plated
Spring: Steel, gold-plated Spring: Steel, gold-plated
Receptacle: Brass, gold-plated Receptacle: Brass, gold-plated
Test probe: S K S 4 1 9 0 0 5 3 0 0 A 6 5 0 8
Test probe: S K S 4 2 9 0 0 5 5 0 0 A 8 0 0 8
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Screw-in Switching Probe
Installation height with KS: 10,2 - 20,0 mm (.402 - .787) Closing version (NO)
Switch path: 1,5 mm (.059)
Standard
GKS
SKS-215 ... M ø 1,65 [.065]
ø 0,4 ø 0,7 ø 0,45
ø 0,51
ø[.020]
0,51
ø 1,65 [.065]
solder and plug connection SW 1,7 [.067]
SW 1,7 [.067]
ø 1 [.039]
ø 1 [.039] Available tip styles
solder
ø 0,7 and plug connection ø 2,3 [.091] ø s.tbl.
ø 0,4
[.016] ø 0,7
[.028] ø[.018]
0,45 [.020] ø 2,3 [.091] ø s.tbl.
Material
ø 0,7
[.028] M1,6 [.063] Further versions
Plating
[.016] [.028] [.018] [.028] M1,6 [.063] Tip style
∅ ∅ (inch)
5
2,5 switching path 2 3
E-TYPE
5
[.197]
DKS
2,5
[.099] switching path
1,5 [.059] 2
[.079] 3
[.118] 0 02
[.197] ∅ 1,80 A
11 [.433] [.099] 1,5 [.059] [.079] [.118]
11 [.433] 5 [.197] (.071)
SE-081 46,5[1.832] 5 [.197]
SE-081 46,5[1.832] 3 02 ∅ 1,80 A 1,00 (.039)
SKS-215 ... M ø 2 [.079] ø 2,2 [.087]
SKS-215 ... M ø 2 [.079] ø 2,2 [.087] (.071)
Flying Probe
Bead Probe
3 03 ∅ 1,80 A
0,2 [.008] (.071)
29,5 [1.161] 0,2 [.008]
KS-215 M1,6 29,5 [1.161] 3 05 A 0,80 (.030)
5 ∅ 0,64
KS-215 M1,6 ø 2 [.079] ø 2,2 [.087] (.025)
ø 2 [.079] ø 2,2 [.087]
Fine Pitch
3 05 ∅ 1,00 A
(.039)
5 [.197]
29,5 [1.161]5 [.197] 1,50A (.059)
29,5 [1.161] 3 06 ∅ 1,80 N 2,00A (.079)
KS-215 M1,6 E05 (.071) 2,30A (.091)
KS-215 M1,6 E05
Quick-exchange system 3 19 ∅ 1,80 A
plug connection
Stand. GKS
SW 1,7 [.067] ø 1 [.039]
SKS-215 ... MF plug connection (.071)
Metric
SW 1,7 [.067] ø 1 [.039]
ø 0,45 [.018] M1,6 [.063] ø 1,65 [.065] ø 2,3 [.091] ø s.tbl.
ø 0,45 [.018] M1,6 [.063] ø 1,65 [.065] ø 2,3 [.091] ø s.tbl.
short / long
[.254] 1,5 [.059] [.079] [.118]
5 [.197]
HSS
50,5 [1.988] 5 [.197] Collar height and installation height
SKS-215 ... MF 50,5 [1.988] Crimps in the receptacle prevent the test
- 20,0
- 20,0
- 610)
ø 1,4
- 787)
[.055] ø 1,8 [.071] ø 2 [.079] ø 2,2 [.087] on heights can be variably achieved with
- 15,5
- 610)
(.197)
(.402)
5 5(.197)
different receptacles.
(.402
10,2
(.402)
15,2
(.598
Robust HSS
Dipole HSS
2 (.079)
(.402
10,2
10,2
10,2
SKS
with
KS-215 M1,6M1,6
KS-215 -E05
E05 (-F/-F-R)
S
ø 1,4KS-215 M1,6-F-R (with knurl)
KS-215 M1,6 E05 - S
ø 1,4
[.055] ø 1,8 [.071] ø 2 [.079] ø 2,2 [.087]
[.055] ø 1,8 [.071] ø 2 [.079] ø 2,2 [.087]
Note:
Step Probes
5 [.197] SKS-215 ... M is screwed into
GKS ... M
42,9 [1.687] 5 [.197]
42,9 [1.687] KS-215 ... M using specialised tools
KS-215 M1,6 E05-F
KS-215 M1,6 E05-F ø 2,05 [.081] (shown on page 196).
ø 2,05 [.081]
Recommended screw-in torque:
Min.: 3 cNm / Max.: 5 cNm
KS-215 M1,6 E05-F-R (with knurl)
rotating GKS
KS-215 M1,6 E05-F-R (with knurl)
VF / Non-
Quick-exchange receptacles:
Mechanical data Materials Receptacles with end designation
Switch path: 1,5 mm (.059) Plunger: BeCu, gold- or nickel-plated “-F” are quick-exchange receptacles.
± 0,2 mm (.008) (or gold-plated with insulator cap) The two wires are soldered to the out-
Working stroke: 4,0 mm (.160) Barrel: Brass, gold-plated side surface of the receptacle and the
RF Test Probes
Dipole-GKS
Maximum stroke: 5,0 mm (.197) Spring: Steel, gold-plated central terminal point after assembling
Force at switching point: 0,23 N (.8 oz); Receptacle: Brass, gold-plated the receptacle in the mounting hole.
0,45 N (1.6 oz); 0,9 N (3.2 oz) Isolated part:Peek The switching probe can now be in-
Force at working stroke: 0,80 N (2.9 oz); serted or changed without any further
1,50 N (5.4 oz); 3,0 N (10.7 oz) Mounting hole size soldering work.
KS without knurl
Electrical data
in CEM1: ∅ 1,97 - 1,99 mm (.0776 - .0783) The quick-exchange system “F” is not
PKS
PSK
Current rating: 3A
in FR4: ∅ 1,98 - 2,00 mm (.0780 - .0787) compatible with the previous versi-
(see page 100)
KS with knurl on “S”, which is still available upon
Operating temperature in CEM1 and FR4: request.
Standard: -40° up to +80° C ∅ 2,00 - 2,02 mm (.0787 - .0795)
Assorted
Ordering example
GKS
Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold at working (mm) (alternative
0 = Delrin N = Nickel stroke (dN) “MF“)
3 = BeCu
Accessories
Test probe: S K S 2 1 5 3 0 2 1 8 0 A 3 0 0 2 M
Plug: S E - 0 8 1
Tools
Material
ø 0,7 [.028] ø 3,2 [.126] ø s. tbl. Further versions
Plating
M 2,5 [.098] ø 2,65 [.104] Tip style
∅ ∅ (inch)
solder and plug connection SW 2,6 [.102] ø 1,8
ø 0,7 [.028] M2,5 ø 2,65 [.104] ø 3,2 [.126] [.071] ø s.tbl. 5,00 (.197)
[.098] 0 02 ∅ 3,00 A 2,30 (.091)
7 [.276] 2 [.079] 3 [.118] (.118)
SKS-463 ... MF
switching path 1,7 [.067] 5,2 [.205]
7,6 [.299] 2 [.079] 3 [.118] 3 02 ∅ 1,80 A
switching path 1,744,8 [1.764]
[.067] 5,2 [.205] (.070)
ø 1,2 ø 2 ø2 ø3 ø 3,2
44,8 [1.764]
ø 3 [.118] ø 3,2 [.126] M2,5 [.098] ø 3 [.118] [.126]
ø[.047]
1,2 ø[.079]
2 ø [.079]
2 ø 3,2 3 02 ∅ 3,00 A
[.047] [.079] [.079] ø 3 [.118] ø 3,2 [.126] M2,5 [.098] [.118] [.126] (.118)
3 03 A
3 [.118] 9 [.354] 5 [.197] 0,2 [.008] ∅ 2,30
3 [.118] 139 [.512]
[.354] 5 [.197] 0,2[.835]
[.008] (.091)
21,2 [.835] 21,2
13for
SE 215 [.512] 21,2 [.835] 21,2 [.835]
ø2,3 0,4
SE 215 for
usage with SKS-465 ... MF KS-465 M2,5 E05 KS-465 M2,5 3 06 ∅ 1,00
A
usage with SKS-463 ... MF KS-465 M2,5 E05 KS-465 M2,5 (.039)
Quick-exchange system
øø1,7
1,7 3 06 ∅ 1,05 A
[.067]
[.067] ø ø2,2
2,2[.087]
[.087] ø 3 ø[.118]
3 [.118] ø 3,2ø[.126]
3,2 [.126] 4,6 (.041)
Quick-exchange receptacles:
20,0
(.598- -.795)
15,2 -- 20,2
Crimps in the receptacle prevent the test probe from Receptacles with end designation
(.413- -.606)
.610)
15,5
10,5 -- 15,4
(.197)
10,5
Receptacle Install. heights Install. height side surface of the receptacle and the
5
2,2
designation with tips with tips 53/56 central terminal point after assembling
02/03/06/19 the receptacle in the mounting hole.
The switching probe can now be in-
KS-465 M2,5 10,4 - 15,4 mm 16,9 - 21,9 mm with with serted or changed without any further
(-F/-F-R) (.413 - .610) (.669 - .866) KS-465 M2,5
with KS-465 M2,5 E05 soldering work.
KS-465
KS-465 M2,5
M2,5-F(-F/-F-R)KS-465 M2,5 E05-F
KS-465 M2,5 E05 15,2 - 20,2 mm 21,7 - 26,7 mm
with
(-F/-F-R) (.598 - .787) (.854 - 1.043) KS-465 M2,5 E05 (-F/-F-R)
The quick-exchange system “F” is not
compatible with the previous versi-
Mechanical data Materials on “S”, which is still available upon
Switch path: 1,7 mm (.067) ± 0,3 mm (.012) Plunger: BeCu, gold-plated request.
Recomm. work. stroke: 4,2 mm (.165) with or without insulator cap
Maximum stroke: 5,2 mm (.205) Barrel: Brass, gold-plated
Force at 0,7 N (2.5oz); Spring: Stainless steel Note:
1,8 N (6.5oz); 4,5 N (15oz) Receptacle: Brass, gold-plated Probes with tip diameter < 3,0 are
Force at work. stroke: 2,0 N (7.2oz); Insulated part: Peek screwed into KS-465...M using tools,
3,5 N (12.7oz); 9,0 N (32.5oz) see page 198. SKS-465 ... MF test
probes with tip diameter > 3,0 mm
Electrical data Mounting hole size are screwed in using specialised tools
Current rating: 3A KS without knurl ∅ 2,98 - 2,99 mm (upon request).
(see page 100) in CEM1 and FR4: (.117 - .118) Recommended screw-in torque:
Operating temperature KS with knurl ∅ 3,00 - 3,02 mm Min.: 3 cNm / Max.: 5 cNm
Standard: -40° up to +80° C in CEM1 and FR4: (.118 - .119)
Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold at working (mm)
Ordering example 0 = Delrin stroke (dN)
3 = BeCu
Test probe: S K S 4 6 5 3 0 6 2 3 0 A 2 0 0 2 M F
Receptacles: K S - 4 6 5 M 2 , 5 (-F / -F - R) K S - 4 6 5 M 2 , 5 E 0 5 (-F / -F - R)
Lamellar plug:
S E - 2 1 5
110 All specifications are subject to change without prior notification
SKS 463 MF
Information
Grid:
Product
≥ 3,50 mm
≥ 140 Mil Screw-in Switching Probe
Installation height with KS: 10,4 - 26,7 mm (.409 - 1.051) Opening version (NC)
Switch path: 1,7 mm (.067)
Standard
GKS
Mounting and functional dimensions Available tip styles
solder and plug connection SW 2,6 [.102] ø 1,8
Material
Further versions
ø 0,7 [.028] M2,5 2,65 [.104] SW ø2,6
3,2 [.126] [.071] ø s.tbl.
Plating
solder and plugøconnection [.102] ø 1,8 Tip style
[.098] ∅
ø 0,7 [.028] ø 3,2 [.126] [.071] ø s.tbl. ∅ (inch)
M2,5 ø 2,65 [.104]
SKS-463 ... MF [.098]
E-TYPE
DKS
SKS-463 ... MF 7,6 [.299] 2 [.079] 3 [.118] 0 02 ∅ 2,30 A 3,00 (.118)
(.091)
switching path 1,7 [.067]
7,6 [.299] 5,2 [.205]
2 [.079] 3 [.118]
44,8 [1.764] 5,2 [.205]
switching path 1,7 [.067]
ø3 ø 3,2 3 02 ∅ 2,30 A 3,00 (.118)
ø 1,2 ø 2 ø2 44,8 [1.764]
M2,5 [.098] (.091)
ø[.047]
1,2 ø[.079]
2 ø[.079]
2
ø 3 [.118] ø 3,2 [.126] ø 3[.118]ø 3,2[.126]
Flying Probe
Bead Probe
[.047] [.079] [.079] ø 3 [.118] ø 3,2 [.126] M2,5 [.098] [.118] [.126]
3 03 ∅ 2,30 A
(.091)
3 [.118] 9 [.354] 5 [.197] 0,2 [.008]
3 [.118] 139[.512]
[.354] 5 [.197]
21,2 [.835] 0,2 [.008]
21,2 [.835] 3 06 ∅ 2,30 A
13for[.512] (.091)
SE 215 21,2 [.835] 21,2 [.835]
usage
SE with SKS-463 ... MF
215 for KS-465 M2,5 E05 KS-465 M2,5
Fine Pitch
usage with SKS-463 ... MF KS-465 M2,5 E05 KS-465 M2,5 3 56* ∅ 2,30 A
Quick-exchange
ø 1,7 system (.091)
ø[.067]
1,7 ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
* tip length 9,5 mm (.374)
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126] total length 6,5 mm (.256) longer than standard
KS-465 M2,5-F
KS-465 M2,5-F
Stand. GKS
Metric
4,2 [.165] 0,2 [.008]
4,2 [.165] 0,2 [.008]
38,1 [1.500]
38,1 [1.500]
ø 3,05 [.120]
ø 3,05 [.120]
KS-465 M2,5-F-R
KS-465
(withM2,5-F-R
short / long
knurl)
ø 1,7 (with knurl)
HSS
ø 1,7
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
Robust HSS
Dipole HSS
4,2[.165]
4,2 [.165] 5 [.197]
5 [.197]
38,1
38,1 [1.500]
[1.500]
ø 3,05
ø 3,05 [.120]
[.120]
KS-465
KS-465 M2,5M2,5 E05-F-R
E05-F-R
(with
(with knurl)
knurl)
SKS
Collar height and Installation height
.787)
20,0
(.598- -.795)
15,2 -- 20,2
10,4
(.409
Step Probes
GKS ... M
(.197)
10,5
rotating GKS
KS-465 M2,5
with KS-465 M2,5 E05
VF / Non-
KS-465 M2,5 15,2 - 20,2 mm 21,7 - 26,7 mm KS-465
KS-465 M2,5
M2,5-F(-F/-F-R)KS-465 M2,5 E05-F side surface of the receptacle and the
E05 (-F/-F-R) (.598 - .795) (.854 - 1.051)
with central terminal point after assembling
KS-465 M2,5 E05 (-F/-F-R)
the receptacle in the mounting hole.
Mechanical data Materials The switching probe can now be in-
Switch path: 1,7 mm (.067) ± 0,2 mm (.008) Plunger: BeCu, gold-plated serted or changed without any further
RF Test Probes
Dipole-GKS
Recomm. work. stroke: 4,0 mm (.157) with or without insulator cap soldering work.
Maximum stroke: 5,0 mm (.197) Barrel: Brass, gold-plated
Force at switching point: 0,93 N (3.35oz); Spring: Stainless steel The quick-exchange system “F” is not
(.026) Receptacle: Brass, gold-plated compatible with the previous versi-
Force at work. stroke: 2,2 N (7.91oz); (.087) Insulated part: Peek on “S”, which is still available upon
request.
Electrical data Mounting hole size
PKS
PSK
Current rating: 3A
KS without knurl ∅ 2,98 - 2,99 mm
(see page 100) in CEM1 and FR4: (.117 - .118) Recommended screw-in torque:
Operating temperature KS with knurl ∅ 3,00 - 3,02 mm Min.: 3 cNm / Max.: 5 cNm
Standard: -40° up to +80° C in CEM1 and FR4: (.118 - .119)
Assorted
Series Tip Tip style Tip diameter Plating Spring force Collar height Type
GKS
Test probe: S K S 4 6 3 3 0 6 2 3 0 A 2 2 0 2 M F
Lamellar plug: S E - 2 1 5
Tools
Material
Further versions
Plating
Tip style for
ø 0,7 [.028] ø 2,65 SW 2,6 [.102] [.089] ø s.tbl. SKS-465 302 / 352 ... S
∅ ∅ (inch)
M2,5 [.098] [.104] ø 3,2 [.126] 0,8 x 2
solder and plug connection ø 2,26
ø 0,7 [.028] ø 2,65 SW 2,6 [.102] [.089] ø s.tbl.[.031] x [.079] ∅ 3,00 A 3,50 (.138)
SKS-465 ... SF for screw-in tool 3 02 4,00 (.157)
M2,5 [.098] [.104] 0,8 x 2 (.118)
switching path 1,7 2 5,4
[.031] x [.079]
SKS-465 ... SF 7 [.276] [.067] [.079] [.213] 2,8 [.110] 5,00 (.197)
for screw-in tool
3 02 ∅ 4,50 A 5,50 (.217)
switching path44,8
1,7 [1.764] 2 5,4 (.177) 5,90 (.232)
7 [.276] [.067] [.079] [.213] ø2,8
s.tbl.
[.110]
44,8 [1.764]
3 52* ∅ 3,00 A 3,50 (.138)
ø s.tbl. (.118)
SKS-465 002 ... SF
Material
Further versions
Plating
Tip style for
3 [.118] 9 [.354] 5 [.197] 0,2 [.008] SKS-465 002 ... S with insulated tip
∅ ∅ (inch)
13 [.512] 21,2 [.835] 21,2 [.835]
SE 215 for 9 [.354]
3 [.118] 5 [.197] 0,2 [.008]
∅ 3,00 A 3,50 (.138)
13 SKS-463
[.512] ... SF 0 02
usage with KS-46521,2
M2,5 E05
[.835] KS-465 M2,5
21,2 [.835] (.118)
4,00 (.157)
SE 215 for
ø 1,7
Quick-exchange KS-465 M2,5 E05 KS-465 M2,5
ø system
usage with SKS-463 ... SF 5,00 (.197)
[.067] 2,2 [.087] ø 3 [.118] ø 3,2 [.126] 0 02 ∅ 4,50 A
5,90 (.232)
(.177)
ø 1,7
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
KS-465 M2,5-F
4,2 [.165] 0,2 [.008] KS-465 M2,5-F
38,1 [1.500]
[0,598 - 0,795]
4,2 [.165] 0,2 [.008]
15,2 - 20,2
ø 3,05 [.120]
[0,409 - 0,606]
10,4 - 15,4
38,1 [1.500]
0,409
ø 3,05 [.120]
0,087
10,4
KS-465 M2,5-F-R
2,2
0,197
(with knurl)
5
ø 1,7 KS-465 M2,5-F-R
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126] (with knurl)
ø 1,7
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
KS-465 M2,5 E05-F
with
4,2 [.165] 5 [.197] KS-465 M2,5 E05-F KS-465 M2,5 (-F/-F-R)
with
38,1 [1.500] KS-465 M2,5 E05 (-F/-F-R)
4,2 [.165] 5 [.197]
ø 3,05 [.120]
38,1 [1.500] Collar height and installation height
ø 3,05 [.120] Crimps in the receptacle prevent the test
KS-465 M2,5 E05-F-R
(with knurl) probe from rotating. Different installation
KS-465 M2,5 E05-F-R heights can be variably achieved with diffe-
(with knurl)
rent receptacles.
Receptacle designation Installation heights with Installation height with Quick-exchange receptacles:
tip style 02 tip style 52 Receptacles with end designation
KS-465 M2,5 (-F/-F-R) 10,4 - 15,4 mm (.409-.606) 16,9 - 21,9 mm (.665-.862) “-F” are quick-exchange receptacles.
The two wires are soldered to the out-
KS-465 M2,5 E05 (-F/-F-R) 15,2 - 20,2 mm (.598-.795) 21,7 - 26,7 mm (.854-1.051)
side surface of the receptacle and the
Mechanical data Materials central terminal point after assembling
Switch path:1,7 mm (.067) ± 0,3 mm (.012) Plunger: BeCu or brass, gold-plated the receptacle in the mounting hole.
Recomm. work. stroke: 4,2 mm (.165) Barrel: Brass, gold-plated The switching probe can now be in-
Maximum stroke: 4,5 mm (.177) Spring: Steel, gold-plated or stainless steel serted or changed without any further
Force at switching point: 0,7 N (2.5oz); Receptacle: Brass, gold-plated soldering work.
1,8 N (6.5oz); 4,5 N (15oz) Isolated part: Peek
Force at work. stroke: 2,0 N (7.2oz); The quick-exchange system “F” is not
3,5 N (12.7oz); 9,0 N (32.5oz) compatible with the previous versi-
on “S”, which is still available upon
Electrical data Mounting hole size request.
Current rating: 3A KS without knurl ∅ 2,98 - 2,99 mm
(see page 100) in CEM1 and FR4: (.117 - .118)
Operating temperature KS with knurl ∅ 3,00 - 3,02 mm Recommended screw-in torque:
Standard: -40° up to +80° C in CEM1 and FR4: (.118 - .119) Min.: 3 cNm / Max.: 5 cNm
Test probe: S K S 4 6 5 3 0 2 4 5 0 A 2 0 0 2 SF
Lamella plug: S E - 2 1 5
112 All specifications are subject to change without prior notification
SKS 115 M
Information
Grid:
Product
≥ 4,00 mm
≥ 157 Mil Screw-in Short Switching Probe
Installation height with KS: 9,2 mm (.362) Closing version (NO)
Switch path: 1,7 mm (.067)
Standard
GKS
Mounting and functional dimensions Available tip styles
further
Material
Standard
Plating
versions
Tip-style
∅ ∅ (inch)
SW 2,6 [.102]
E-TYPE
plug connection ø 3,5 [.138] ø 1,8 [.071]
DKS
0 02 A 3,0 A
ø 0,7 [.028] M3 [.118] ø s.tbl. ∅ 2,00
ø 2,46 [.097]
3 02 A
SKS-115 M ∅ 1,00
Flying Probe
Bead Probe
3,15 [.124] 6,8 [.268] 3 02 A 3,0 A
2,2 [.086] ∅ 2,00
25,15 [.990]
3 06 A
ø 2,98 [.117] ∅ 1,00
Fine Pitch
ø 1,7 [.067] ø 2,2 [.087] ø 3,5 [.138] ø 3,7 [.146]
3 06 A 3,0 A
∅ 2,00
KS-115 M3 F
Stand. GKS
7 [.276]
Metric
23,7 [.933]
ø 3,57 [.141]
KS-115 M3 F-R
short / long
(with knurl)
HSS
Robust HSS
Dipole HSS
SKS
Step Probes
GKS ... M
rotating GKS
VF / Non-
Mechanical data Materials
Switch path: 1,7 mm (.067) + 0,2 (.008) Plunger: BeCu, gold-plated Quick-exchange receptacles:
Recomm. work. stroke: 4,0 mm (.157) (or gold-plated with insulator cap) The two wires are soldered to the out-
Maximum stroke: 5,0 mm (.197) Barrel: Brass, gold-plated side surface of the receptacle and the
Spring force at switch.point: 0,5 N (1.8oz) Spring: Steel, gold-plated central terminal point after assembling
RF Test Probes
Dipole-GKS
0,7 N (2.5oz); 1,3 N (4.7oz) Receptacle: Brass, gold-plated the receptacle in the mounting hole.
Spring force at work.stroke: 1,5 N (5.4oz) Isolated part: Peek The switching probe can now be in-
2,0 N (7.2oz); 3,0 N (10.79oz) serted or changed without any further
soldering work.
Electrical data Mounting hole size
Current rating: 3A KS without knurl ∅ 3,48 - 3,49 mm
(see page 100) in CEM1 and FR4: (.137 - .137)
PKS
PSK
Test probe: S K S 1 1 5 3 0 6 1 0 0 A 1 5 0 2 M
Receptacles: K S – 1 1 5 M 3 F K S – 1 1 5 M 3 F - R
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
solder connection
M2,5 x 0.25 ø3 (.118) SW3 (.118) Ø2,9 1 02 ∅ 2,90 A
Ø1 Ø2,15 (.114)
(.098 x .010) Ø3,75 (.148) (.114)
(.039) (.085)
2,5 (.098)
6,5
(.226) 20,5 (.807)
83,9 (3.303)
5,5 15 0,3
(.217) (.591) (.012)
43 (1.693)
KS-435 M2,5
Test probe: S K S 4 3 5 1 0 2 2 9 0 A 1 3 5 M
Receptacle: K S - 4 3 5 M2.5
Screw-in test probes are often used to contact cable har- The cable harness has to pass various tests before it is fitted,
nesses and plug connectors. They remain securely positioned these include: connection test, position test, push-back test,
in the receptacle even under challenging test conditions with and function test.
vibrations or axial force. Screw-in test probes with thread
have the designation ‘M’ at the end of the part number. A further area of application for screw-in probes is the con-
tacting of plug connectors on various electronic devices, such
Cable harnesses are the central connection elements between car radios, control units, PCs, smart devices, and many more.
various components in the automobile industry and mechanical
engineering and supply these with either power or signals.
To guarantee uninterrupted operation, high demands are
placed on the cable harness as well as the plug connector used.
116
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Screw-in Test Probes
Many press-in test probes offered by INGUN are also avail-
Screw-in test probes 120 - 134
able as a screw-in version. Thus, a secure hold during
Fine Pitch
testing is guaranteed. Screw-in probes are especially recom- Step probes 135 - 140
mended for applications with possible vibrations or un-
wanted side forces and axial forces. Push-back probes 142 - 145
Stand. GKS
Step probes are inserted in the plug housings to test the Non-rotating
Metric
correct position of the contact terminals (contact sheets). test probes 146 - 151
Contact will only occur when the pin of the step probe is (93 - 95)
correctly positioned. INGUN offers a wide variety of step
short / long
probes with tip dimensions, stop collar (disk) dimensions,
HSS
and pin length.
Robust HSS
Dipole HSS
in the correct position, and cannot be pushed back. For this
test, push-back probes with a spring force of up to 34 N are
used.
SKS
contacted in one position, non-rotating probes are used.
These probes are already aligned in the correct position
during assembly.
Step Probes
GKS ... M
rotating GKS
VF / Non-
RF Test Probes
Dipole-GKS
Note:
See High Current Probes chap-
PKS
PSK
Note:
See next page for overview
and comparison table.
Tools
117
117
Technical Information
Grid Installation
Working Max. Spring forces Shortest
size Current height with re-
Test probe version Series stroke stroke (N) probe Page
(≥ mm) rating (A) ceptacle (mm)
(mm) (mm) (mm)
min. max. min. max.
GKS-087 M 1.27 4 5 2–3 0.5 0.8 7.2 8.2 28 120
GKS-050 M 1.27 4.3 6.35 2–3 1 2 10.5 12.5 47.3 121
GKS-075 M 1.91 4.3 6.35 3–4 0.6 2.8 10.5 - 35.9 122
GKS-427 M 2.54 3.5 4.5 5–8 0.8 2.5 8.7 - 19.5 123
GKS-899 M 2.54 3.5 4.4 3–5 0.7 3 12.8 - 27.9 124
GKS-112 M 2.54 4 5.3 / 8 5–8 0.6 5 10.5 19 35.8 125
GKS-204 M 2.54 8 10 5–8 0.8 3 16 23 47.9 126
Screw-in test
GKS-913 M 4 2.8 3.5 5–8 0.8 2.5 7.3 8.9 17.1 127
probes
GKS-113 M 4 4 5.3 5–8 0.3 5 10.5 - 28.3 128
GKS-103 M 4 4.8 6 5–8 0.8 5 12.55 - 32 129
GKS-503 M 4 5.6 7 5 – 15 1.5 5 13.25 - 38 130
GKS-500 M 4.5 5.6 7 5 – 15 1.5 5 13.25 - 38 131
GKS-854 M 5.08 4.4 5.5 10 – 12 3 5 10.8 - 43.1 132
GKS-212 M 2.54 12 14.5 2–3 3 - 25.2 - 67.5 133
GKS-313 M 4.5 12 14.3 3–5 1.5 3 19.5 25 57.3 134
T-899 M 2.54 3.5 4.4 3–5 0.7 3 12 14.8 27.1 135
T-112 M 2.54 4 5 5–8 0.6 5 9.2 12.7 34.5 136
T-912 M 2.54 4 5 5–8 1.5 5 8.9 13.7 34.2 137
Step probes
T-113 M 4 4 5 5–8 0.3 5 9.5 14.3 27.3 138
T-888 M 4 4 5 5–8 1.5 3 9.5 14.3 27.3 139
T-785 M 4.5 4 5.3 16 10 14.3 15.3 52.1 140
VF 25 2.54 5 6 5 10 15 40.5 - 69.5 142
VF 3 3 5 5.5 8 5 15 40.5 46.5 69.7 143
Push-back probes
VF 4 5 5.5 7 8 15 25 40.5 46.5 69.5 144
VF 5 5 9.5 12 10 15 34 36.7 - 96 145
GKS-710 2.54 4 5 5–8 1.5 5 13.2 18.2 35.1 146
GKS-746 M 2.54 4 4.4 5–8 1.5 3 10.5 - 40.2 147
GKS-747 M 4.5 4 5 8 1.5 3 16.2 20.2 36 148
GKS-803 M 4.5 6.4 8 5 – 15 1.5 5 18.3 - 48 149
Non-rotating test GKS-714 5.08 4 / 6 5 / 7 8 – 10 1.5 5 15 22.2 29.8 150
probes GKS-098 5.08 4 5 8 – 10 1.5 5 15.75 - 28.5 150
GKS-098 M 5.08 4 5 8 – 10 1.5 3 15.3 - 40 151
VK-541 3.5 3.5 6.5 10 - - 19.1 - 53.5 93
HKF-617 5.5 4.4 5.5 20/40 10 27.9 57.9 94
KK-541 3.5 3.5 6.5 20 - - 16.35 16.55 34.35 95
118
Information
Product
Contents
Technical Information
Standard
GKS
Step Probes
E-TYPE
DKS
Flying Probe
Bead Probe
Screw-in Test Probes
Many press-in test probes offered by INGUN are also avail- GKS-087 M 120
GKS-050 M 121
able as a screw-in version. Thus, a secure hold during
Fine Pitch
GKS-075 M 122
testing is guaranteed. GKS-427 M 123
GKS-899 M 124
Screw-in probes are especially recommended for applica- GKS-112 M 125
tions with possible vibrations or unwanted side forces and GKS-204 M 126
Stand. GKS
axial forces (loosening of probe is avoided). GKS-913 M 127
Metric
GKS-113 M 128
The test probes are screwed into the receptacle using the GKS-103 M 129
appropriate tools. The required screw-in torque is achieved GKS-503 M 130
Scale 1:1 (mm) GKS-500 M 131
short / long
by the spanner flat on the barrel.
GKS-854 M 132
HSS
GKS-212 M 133
The electrical connection is made via the receptacle using a GKS-313 M 134
100 solder cup or wire-wrap. Receptacles also sometimes feature
an axial bore hole for leakage tests, or are designed to be Step Probes
Robust HSS
Dipole HSS
90 vacuum sealed.
T-899 M 135
Step probes are inserted in the plug housings to test the T-112 M 136
80 T-912 M 137
correct position of the contact terminals (contact sheets).
T-113 M 138
Contact will only occur when the pin of the step probe is
T-888 M 139
SKS
70 correctly positioned. INGUN offers a wide variety of step
T-785 M 140
probes with tip dimensions, stop collar (disk) dimensions and
60 pin length.
Step Probes
GKS ... M
The step probes are screwed into the receptacle using the
50
spanner flat on the barrel, or a positive-locking connection
on the tip of the plunger.
40
rotating GKS
VF / Non-
30
POS-NR. BENENNUNG
1 Milimetereinteilung
Katalog
2 GKS-050 305 050 A
1503 M Katalog
GKS-075 M
GKS-427 M
GKS-899 M
GKS-112 M
GKS-113 M
GKS-103 M
GKS-212 M
POS-NR.
POS-NR.
POS-NR.
BENENNUNG
BENENNUNG
BENENNUNG
GKS-113 303 230 A
PKS
PSK
7 Milimetereinteilung
Milimetereinteilung
Milimetereinteilung
T-899 M
T-113 M
T-785 M
1502 M Katalog 1 1
Katalog 1
KatalogKatalog
-20
Assorted
70
GKS
-30
60
Accessories
-40
50 Note:
Shown without KS - other installation heights available See page 118 for overview
-50 and comparison table.
40
-60
Tools
30 119
119
GKS 087 M Grid:
≥ 1,27 mm
Screw-in Test Probe ≥ 50 Mil
Installation height with KS: 7,2 / 8,2 mm (.283 / .323)
Recommended stroke: 4,0 mm (.157)
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
5 (.197)
3 03 ∅ 0,90 A
7 (.276)
28 (1.102) (.035)
5 (.197) 1
8 (.315) (.039)
29 (1.142)
GKS-087 303 090 A xx 02 M
ø 0,5
(.0197)
5 (.197)
28 (1.102) 7 (.276)
Receptacles
ø 0,8 ø 0,97 ø1 ø 1,15
(.031) (.038) (.039) (.045)
6 0,2 (.008)
(.236) 27 (1.063)
KS -087 M 0.7 H
8,2
Operating temperature
Standard: -40° up to +80° C
Test probe: G K S 0 8 7 3 0 5 0 5 0 A 0 5 0 2 M
Receptacles: K S – 0 8 7 M 0 ,7 H K S – 0 8 7 4 7 M 0,7
Information
Grid:
Product
≥ 1,27 mm
≥ 50 Mil Screw-in Test Probe
Installation height with KS: 10,5 / 12,5 mm (.413 - .492)
Recommended stroke: 4,3 mm (.169)
Standard
GKS
Mounting and functional dimensions Available tip styles
version GKS-050 ... M
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
SW 0,9 [.035] ø 0,5 [.020]
E-TYPE
DKS
M0,7 [.028] ø 0,79 [.031] ø 1,15 [.045] ø s.tbl. 2 01 ∅ 0,50 A
(.020)
GKS-050 ... M
2,9 [.114] 0,55 [.022] 3 02 ∅ 0,60 A
(.023)
Flying Probe
Bead Probe
6,35 [.250]
47,3 [1.862] ∅ 0,50 A
3 03 0,90 (.035)
(.020)
Fine Pitch
49,3 [1.941]
3 06 ∅ 0,90 A
(.035)
ø 0,5 [.020]
ø 0,81 [.032] ø 1 [.039] ø 1,15 [.045] 3 07 ∅ 0,50 A 0,90 (.035)
(.020)
Stand. GKS
KS-050 35 M
Metric
0,5 [.020] 2 14 ∅ 0,50 A
(.020)
43,5 [1.713]
19 ∅ 0,90
3 *
(.035)
short / long
22
HSS
2 ** ∅ 0,40 A
(.020)
2 31 ∅ 0,50 A
(.020)
Robust HSS
Dipole HSS
2 38 ∅ 0,50 A
(.020)
Collar height and installation height
12,5 (.492)
10,5 (.413)
SKS
(.020)
Step Probes
GKS ... M
03 ML 12,5 mm (.492) ** conical down to ∅ 0,50 mm
GKS-050 ...ML GKS-050 ...M
(with KS-050...)
Available tip styles
special version GKS-050 ... ML
Material
Further versions
Mechanical data Materials
Plating
Tip style
rotating GKS
VF / Non-
Working stroke: 4,3 mm (.169) Plunger: BeCu or steel, gold-plated ∅ ∅ (inch)
Maximum stroke: 6,35 mm (.250) Barrel: Brass, gold-plated
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated 2 91 ∅ 0,50 A
(.020)
Alternative: 1,0 N (3.6oz); 2,0 N (7.2oz) or stainless steel** (MC)
Receptacle: Brass, gold-plated Total length 49,3 mm (1.941), special designation“ML“ RF Test Probes
Dipole-GKS
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 0,64 [.025]
ø0,8
M1 [.039] ø 1 [.039] ø 1,4 [.055] SW 1 [.039] ø s.tbl.
0 06* A
∅ 1,30
0,8
(.051)
GKS-075 ... M
2,2 [.087] 1,3 [.051] 2 01 ∅ 0,64 A
6,4 [.252] (.025)
1,00 (.039)
2 07 ∅ 0,64 A
1,20 (.047)
(.025)
2 09 ∅ 0,64 A
(.025)
3 13 ∅ 0,61 A
(.024)
0,64 (.025)
2 14 ∅ 0,50 A 0,80 (.031)
(.020) 1,00 (.039)
2 17 ∅ 1,20 A
(.413)
10,5
(.047)
2 31 ∅ 0,64 A
Mechanical data Materials (.025)
Working stroke: 4,3 mm (.169) Plunger: BeCu or steel, gold-plated
Maximum stroke: 6,35 mm (.250) Barrel: Brass, gold-plated 2 77 ∅ 0,64 A
Spring force at work. stroke: 2,0 N (7.2oz) Spring: Steel, gold-plated or stainless steel (.025)
Operating temperature * Tip height: 2,8 mm (.110), total length GKS 1,5 mm
Standard: -40° up to +80° C Recommended screw-in torque: (.059) longer than standard
**with spec. desig."MC": Min.: 0,5 cNm / Max.: 1 cNm Further tip styles see GKS-075, shown on page 26/27
*** higher middle tip plus 0,2 mm
-100° up to +200°C (2,0 N; 2,8 N)
Test probe: G K S 0 7 5 2 0 1 0 6 4 A 1 5 0 2 M
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Screw-in Test Probe
Installation height with KS: 8,7 mm (.343)
Recommended stroke: 3,5 mm (.138)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
M1,6 ø1,65 SW1,7 ø1 2 01 ∅ 1,00 A
øs.tbl.
(.039)
(.063) (.065) (.067) (.039)
Flying Probe
Bead Probe
2 4,5 2 (.079) 3 05 ∅ 0,64 A 0,80 A
(.079) (.177) 4 (.025)
19,5 (.768)
3 05 ∅ 1,00 A
(.039)
Fine Pitch
ø1,95 ø2 ø2,05 ø2,2 3 06 ∅ 2,00 A 1,30 A
(.077) (.079) (.081) (.087) (.079)
KS-427 30 M-R
3 13 ∅ 1,00 A
(.039)
(.008) 0,2
Stand. GKS
16,5 (.650)
Metric
3 17 ∅ 2,00 A
(.079)
short / long
HSS
Robust HSS
Dipole HSS
SKS
Step Probes
GKS ... M
Mechanical data Materials
Working stroke: 3,5 mm (.138) Plunger: BeCu or steel, gold-plated Recommended screw-in torque:
rotating GKS
VF / Non-
Maximum stroke: 4,5 mm (.177) Barrel: Brass, gold-plated Min.: 3 cNm / Max.: 5 cNm
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Stainless steel (*MC) or steel,
Alternative: 0,8 N (7.2oz); 2,5 N (9.0oz) gold-plated
Receptacle: Brass, gold-plated RF Test Probes
Dipole-GKS
Operating temperature
Standard: -40° up to +80° C
PKS
PSK
Ordering example
GKS
Series Tip Tip style Tip diameter Plating Spring force Collar height Type
material (1/100 mm) A = Gold (dN) (mm) alternative
2 = Steel “MC”
3 = BeCu
Accessories
Test probe: G K S 4 2 7 3 0 6 2 0 0 A 1 5 0 2 M
Receptacle. K S – 4 2 7 3 0 M-R
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
3,4 (.134)
24,5 (.965)
KS-899 30 M-R **
Operating temperature
Standard: -40° up to +80° C
2 = Steel
3 = BeCu
Test probe: G K S 8 9 9 3 0 6 1 3 0 A 1 5 0 2 M
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Screw-in Test Probe
Installation height with KS: 10,5/13,5/19,0 mm (.413/535/.748)
Recommended stroke: 4,0 / 6,4 mm (.157/.252)
Standard
ø 2,3 [.091]
GKS
SW 1,7 [.067] ø 1 [.039] Available tip styles
M1,6 [.063] ø 1,65 [.065] ø s.tbl.
Material
Further versions
Plating
Tip style
GKS-112 ... 02 M ∅ ∅ (inch)
5,3
E-TYPE
∅ 1,00 R
DKS
2 [.079] [.209] 3 [.118] 2 01 A 0,80 (.031)
35,8 [1.409] (.039)
02
GKS-112 ... 05 M 3 ** ∅ 0,64 A
5,3 ** 3 (.025)
4,4 [.173] [.209] 3 [.118]
Flying Probe
Bead Probe
38,8 [1.528] 3 02 ∅ 0,64 A
5 (.025)
GKS-112 ... 10 M
3 02 ∅ 0,80 A
10,5 [.413] 8,3 [.327] (.031)
44,3 [1.744] (.039)
1,00
3 02 ∅ 2,00 A
1,50
ø 2 [.079] ø 2,2 [.087] (.059)
Fine Pitch
(.079)
1,40 (.055)
KS-112 30 M-T 3 03 ∅ 2,00 A
1,80 (.071)
(.079)
0,2 [.008]
35 [1.378] 2 04 ∅ 2,00 R 1,30 (.051)
(.079)
Stand. GKS
KS-112 30 M *****
Metric
05
3 ** ∅ 0,63 A
ø 2,05
2,7 (.025)
ø 2 [.079] [.081] ø 2,2 [.087] 05
3 ** ∅ 0,64 A
** 3 (.025)
KS-112 30 M-R-Z *****
short / long
0,2 [.008] 3 05 ∅ 0,64 A 0,80 (.031)
5
HSS
(.025)
35 [1.378]
1,00 (.039)
3 05 ∅ 2,00 A 1,40 (.055)
KS-112 30 M-R (.079) 2,30 (.091)
0,2 [.008]
0,748
19
ø1,8
0,531
13,5
Robust HSS
33 [1.299]
Dipole HSS
0 06* A
0,413
10,5
0,8 ∅ 2,30
0,6 [.024] ø 2 [.079] ø 2,2 [.087] (.091)
KS-112 46 M 3 06 ∅ 2,00 A
(.079)
8,2 [.323] 0,2 [.008] 1,30 (.051)
37,2 [1.465] 1,50 (.059)
3 06 ∅ 2,00 R
1,80 (.071)
(.079)
SKS
***** axially positioned through-hole for leakage test. Attention: 2,50 (.098)
when not assembled correctly, then solder can flow inside the receptacle. GKS-112 GKS-112 GKS-112
R 1,30 A
E02 M E05 M E10 M 2 07 ∅ 2,00
A
(.051)
Plug VS-112 M is used instead of a test probe (.079)
to prevent receptacles being used unnecesarily during
maintenance. Collar height Install. height with KS 09
2 *** ∅ 0,60 N
Step Probes
GKS ... M
(.024)
VS-112 M
02 10,5 mm (.413)
M1,6 (.063) ø1,65 (.065) (.091) ø2,3 SW1,7 2 14 ∅ 1,30 A 1,30 R (.051)
(.067) 05 13,5 mm (.531) (.051)
rotating GKS
Mechanical data Materials
VF / Non-
Working stroke: 4,0 mm (.157) Plunger: BeCu or steel, gold-, 3 19 ∅ 1,80 A 2,00 (.079)
(.071)
Maximum stroke: 5,3 mm (.209) rhodium or chemically nickel-plated
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Brass, gold-plated * also available as tip style 0 02 and 0 03
Alternative: 0,6 (2.1oz); 0,8 (2.9oz); 2,25 Spring: Steel, gold-plated or stainless steel (MC) Installation height plus 0,8 mm (.031)
(8.1oz); 3,0 (10.8oz); 5,0 N (18.1oz) Receptacle: Brass, gold-plated
RF Test Probes
** plunger with defined wobble, spec. designation... MT
Dipole-GKS
Test probes with tip diameter < 1,0 mm Mounting hole size **** tip style with special designation "M-30"
(.039) have a maximum stroke of 8,0 for KS-112 xx M and KS-112 xx M-T
mm (.315) in CEM1 and FR4: ∅ 1,98 -1,99 mm Collar height and installation height
Exception: 5,0 N-spring (18.1oz): max. (.0780 - .0783) The installation height of the tip (measured
stroke is always 5,3 mm (.209) for KS-112 xx M-R / M-R-Z with the receptacle) is determined by the
collar height. The test probe can only be
PKS
PSK
3 = BeCu
Test probe: G K S 1 1 2 2 0 4 1 3 0 R 1 5 0 2 M 30
Plug: V S 1 1 2 M
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
2 06 ∅ 1,80 R
(.071)
2 07 ∅ 1,30 A
(.051)
2 14 ∅ 1,30 A
(.051)
2 15* ∅ 1,80 A
(.071)
2 24 ∅ 2,00 R
(.079)
Operating temperature
Standard: -40° up to +80° C
Test probe: G K S 2 0 4 2 0 4 1 3 0 A 1 5 1 0 M
Receptacle: K S – 2 0 4 3 0 M
Information
Grid:
Product
≥ 4,00 mm
≥ 160 Mil Short-stroke Screw-in Test Probe
Installation height: 7,3 / 8,9 mm (.287 / .350)
Recommended stroke: 2,8 mm (.110)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
M2 ø2,65 SW3 ø 3 ø s.tbl.
E-TYPE
(.079) (.104) (.118) (.118)
DKS
1 02 ∅ 2,30 A 3,50 (.138)
(.091)
GKS-913 ... M
(.079) 2 3,5 1,6 3 03 ∅ 2,30 A
(.138) (.063) (.091)
17,1 (.673)
Flying Probe
Bead Probe
3 05 ∅ 2,30 A
(.091)
Ø2 ø3 ø 3,3
(.079) (.118) (.130) ø2,3 0,3
3 06* A
KS-913 35 M ∅ 1,80
(.071)
Fine Pitch
0,2 (.008) (.138)
3,50 R
3 06 ∅ 2,30 A
2,30 R
13,6 (.535) (.091)
(.091)
3 08 ∅ 2,30 R
Ø2 ø3 Ø3,05 ø 3,3 (.091)
Stand. GKS
(.079) (.118) (.120) (.130)
Metric
KS-913 35 M-R 58
3 ** R
∅ 2,30
(.008) Tip length 3,4 mm (.134) (.091)
0,2
13,6 (.535) * see table collar height and installation height
short / long
** see table collar height and installation height
HSS
Robust HSS
Dipole HSS
Collar height and installation height
The installation height of the tip is determined by the
collar height.
SKS
Collar Tip style Install. height max. stroke
height without KS
Step Probes
GKS ... M
02 06 180* 7,1 mm (.280) 3,2 mm (.126)
02 58** 8,7 mm (.343) 3,3 mm (.130)
rotating GKS
Working stroke: 2,8 mm (.110) Plunger: Brass or BeCu,
VF / Non-
Maximum stroke: see table gold- or rhodium-plated see HSS-520 (M) shown on page 87
Spring force at work. stroke: 1,5 N (5.4oz) Barrel: Brass, gold-plated
Alternative: 0,8 N (2.9oz); 2,5 N (9.0oz) Spring: Steel, gold-plated Recommended screw-in torque:
or stainless steel*** (C) Min.: 5 cNm / Max.: 10 cNm
Receptacle: Brass, gold-plated
RF Test Probes
Dipole-GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
GKS
Test probe: G K S 9 1 3 3 0 8 2 3 0 R 1 5 0 2 M
Receptacle: K S – 9 1 3 3 5 M K S – 9 1 3 3 5 M - R
Tools
Material
Further versions
Plating
Tip style
SW 3 [.118] ∅ ∅ (inch)
ø 3,6 [.142] ø 1,8 [.071]
2 01 ∅ 1,80 R
M 2 [.079] ø 2,65 [.104] ø s.tbl. (.071)
0,80 (.031)
∅ 1,40
1,00 (.039)
GKS-113 ... M 3 02
(.055)
A 1,80 (.071)
∅ 2,30
3,00 (.118)
(.091) 4,00
2 [.079] 3 [.118] (.157)
5,3 [.209]
2 03 ∅ 3,00 A
28,3 [1.114] (.118)
KS-113 30 M2-T
1,80 A (.071)
2 04 ∅ 2,30 R
3,00 (.118)
(.091)
0,2 [.008]
27 [1.063] 0,80 (.031)
3 05 ∅ 2,30 A 1,40 (.055)
(.091) 3,00 R (.118)
KS-113 30 M2 ***
3 55 R
∅ 3,00
Tip 4 mm (.157) longer (.118)
ø 3 [.118] ø 3,05 [.120] 1,60 (.063)
2,30 (.091)
3 06 ∅ 3,00 A
4,00 (.157)
(.118) 8,00 (.315)
KS-113 30 M2-R
2,50 (.098)
3,00 (.118)
3 06 ∅ 2,30 R 3,50 (.138)
(.091) 4,00 (.157)
6,00 (.236)
KS-113 30 M2-R-S ****
2 07 ∅ 3,00 A
(.118)
*** axially positioned through-hole for leakage test.
Attention: when not assembled correctly, solder can flow inside the receptacle. 3 07 ∅ 4,20 R
(.165)
**** Additional crimping points for self locking
3 12 ∅ 1,80 A
(.071)
Test probe: G K S 1 1 3 3 0 6 2 3 0 R 1 5 0 2 M
Information
Grid:
Product
≥ 4,00 mm
≥ 160 Mil Universal Test Probe with High Stability
Installation height with KS: 12,5 mm (.492)
Recommended stroke: 4,8 mm (.189)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
(.098) (.118) (.118) 2 01 ∅ 1,80 A
(.071)
GKS-103 ... M
(.079) 2 6,3 4 (.157) 1 02 ∅ 2,30 A 4,00 (.157)
(.248) (.091)
32,3 (1.272)
Flying Probe
Bead Probe
M2,5 ø3,5 ø3,9 2 02 A
(.098) (.138) (.154) ∅ 6,50
(.256)
KS-500 M2,5
0,25 1 03 ∅ 2,30 A 4,00 (.157)
(.091)
20,7(.815) (.010)
Fine Pitch
ø3,5 ø3,9 2 04 ∅ 2,30 A 4,00 (.157)
(.091)
(.138) (.154)
KS-103 30 M2,5
KS-103 30 M2,5-S ** 1 05 ∅ 2,30 A 4,00 (.157)
(.091)
0,25
Stand. GKS
Metric
30,5 (1.201) (.010) 4,00 (.157)
2 06 A 6,50 (.256)
∅ 2,30
9,00 (.354)
(.091)
short / long
HSS
Robust HSS
Dipole HSS
Collar height and installation height
The installation height of the tip is deter-
SKS
mined by the collar height.
Step Probes
GKS ... M
02 12,3 mm (.484)
rotating GKS
The receptacle can be used from grid
VF / Non-
Maximum stroke: 6,0 mm (.236) Barrel: Brass, gold-plated
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated size 4,50 mm (177 Mil) upwards.
Alternative: 0,8 N (2.9oz); 3,0 N (10.8oz), or stainless steel* (C)
5,0 N (18.1oz) Receptacle: Brass, gold-plated ** KS-103 30 M2,5-S:
The test probes is secured in the recep- RF Test Probes
Electrical data Mounting hole size tacle by means of a crimp.
Dipole-GKS
1 = Brass “MC”
GKS
2 = Steel
Test probe: G K S 1 0 3 2 0 1 1 8 0 A 1 5 0 2 M
Accessories
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
2 01 ∅ 1,80 R
(.071)
ø 1,4 Continuous Plunger
(.055) M2,5 ø3 SW3 øs. tbl.
3 03 ∅ 4,00 A
(.098) (.118) (.118) (.157)
3 04 ∅ 4,00 R
5 20 (.787) 2 7 4 (.157)
(.157)
(.197) (.079) (.276)
38 (1.496)
2 05 ∅ 1,80 R
M2,5 ø3,5 ø3,9 (.071)
(.098) (.138) (.154)
R 3,00 R
3 06 ∅ 4,00
A
(.118)
KS-500 M2,5 (.157)
0,25
20,7(.815) (.010) 2 06 ∅ 1,80 R
(.071)
13 (.512)
2 (.079)
Test probe: G K S 5 0 3 2 0 1 1 8 0 R 1 5 0 2 M
Receptacles: K S – 5 0 0 M 2 .5
Lamellar plug: S E – 5 0 3
(for plugging onto the end of the plunger)
Information
Grid:
Product
≥ 4,50 mm
≥ 177 Mil Screw-in Test Probe with Continuous Plunger
Installation height with KS: 13,2 mm (.520)
Recommended stroke: 5,6 mm (.220)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
4,00
DKS
3 06 ∅ 3,00 A A
(.118)
(.157)
continous plunger
1,4 M 2,5 3 3,5 1,8
0,055 0,098 0,118 0,138 0,071 s.tbl.
Flying Probe
Bead Probe
5 2 7,5 3,5
0,197 0,079 0,295 0,138
38
1,496
Fine Pitch
M 2,5 3,5 3,9
0,098 0,138 0,154
Stand. GKS
Metric
0,25
20,7 0,01
0,815
short / long
HSS
Robust HSS
Dipole HSS
Collar height and installation height
The installation height of the tip is always
13,0 mm (.551). The test probe can only be
used with a receptacle.
SKS
Collar height Installation height
without KS
02 13,0 mm (.512)
Step Probes
GKS ... M
Mechanical data Materials
Recommended screw-in torque:
Working stroke: 5,6 mm (.220) Plunger: BeCu, gold-plated
Min.: 10 cNm / Max.: 20 cNm
Maximum stroke: 7,0 mm (.276) Barrel: Brass, gold-plated
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated
Alternative: 3,0 N (10.8oz); 5,0 N (18.1oz) Receptacle: Brass, gold-plated
rotating GKS
VF / Non-
Electrical data Mounting hole size
Current rating in CEM1 and FR4: ∅ 3,48 - 3,49 mm
Connection to plunger: 12 - 15 A (.1370 - .1374)
RF Test Probes
Dipole-GKS
3 = BeCu
Assorted
GKS
Test probe: G K S 5 0 0 3 0 6 3 0 0 A 1 5 0 2 M
Receptacle: K S – 5 0 0 M 2,5
Accessories
Tools
Material
Further versions
Plating
Tip style
M3 [.118] ø 3,5 [.138] ø 4 [.157] ø s.tbl. ∅ ∅ (inch)
3 19 ∅ 4,00 A
GKS-854 ... M (.157)
KS-150 30 M3
0,3 [.012]
43 [1.693]
ø 4,05 [.159]
KS-150 30 M3-R
KS-150 M3 M3-R
Test probe: G K S 8 5 4 3 1 9 4 0 0 A 3 0 0 2 M
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Screw-in Test Probe
Installation height with KS: 25,2 mm (.992)
Recommended stroke: 12,0 mm (.472)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
M1,6 ø1,65 ø2 SW1,7 ø1,3 øs.tbl. 3 06 ∅ 2,00 A
(.079)
(.063) (.065) (.079) (.067) (.051)
Flying Probe
(.295) (.571) (.118)
Bead Probe
67,5 (2.657)
ø2 ø2,2
(.079) (.087)
KS-212 30 M
0,2
Fine Pitch
50 (1.969 (.008)
Stand. GKS
Metric
short / long
HSS
Robust HSS
Dipole HSS
Collar height and installation height
The installation height of the tip (measured
with the receptacle) is determined by the
collar height. The test probe can only be
used with a receptacle.
SKS
Collar height Installation height
without KS
Step Probes
07 25 mm (.984)
GKS ... M
Mechanical data Materials
Recommended screw-in torque:
Working stroke: 12 mm (.472) Plunger: BeCu, gold-plated
Min.: 3 cNm / Max.: 5 cNm
Maximum stroke: 14,5 mm (.571) Barrel: Brass, gold-plated
rotating GKS
VF / Non-
Spring force at work. stroke: 3 N (10.8oz) Spring: Steel, gold-plated
Receptacle: Brass, gold-plated
Ri typical: < 20 mW
Operating temperature
Standard: -40° up to +80° C
PKS
PSK
3 = BeCu
Test probe: G K S 2 1 2 3 0 7 2 0 0 A 3 0 0 7 M
Accessories
Receptacle: K S – 2 1 2 3 0 M
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
3 06 ∅ 3,00 A
38 (1.496) 14,8 (.118)
2 8
(.079) (.583) (.315)
62,8 3 17 ∅ 2,00 R
(2.472) (.079)
GKS-313 302 100 A xx02 M
ø s. tbl.
ø3 ø 3,2
(.118) (.126)
8 0,2
(.315) (.008)
47,5
(1.870)
KS-313 30 M2
Test probe: G K S 3 1 3 3 0 2 1 0 0 A 3 0 0 2 M
Receptacle: K S – 3 1 3 3 0 M2
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Screw-in Step Probes
Installation height with KS: see table
Recommended stroke: 3,5 mm (.138)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
øC ∅ ∅ (inch)
M1,4 ø1,37 ø1,9 SW1,4
øA
E-TYPE
(.055) (.054) (.075) (.055)
DKS
3 02 ∅ s. table A
18,5 (.728) F B 3 05 A
∅ s. table
D
Flying Probe
Bead Probe
05
3 G A
* ∅ s. table
Fine Pitch
KS-899 30 M-R-T
3,4 (.134)
24,5 (.965)
Stand. GKS
KS-899 30 M-R **
Metric
** axially positioned through-hole for leakage test. Attention: when not
assembled correctly, then solder can flow inside the receptacle.
øA
short / long
B
øC
HSS
E
Robust HSS
Dipole HSS
Collar height and installation height
Installation height shown in table below.
The test probe can only be used with a
receptacle.
A B C D E F
SKS
Part No. Tip-Ø Tip length Disk-Ø Total length Install.height Disk height Working Max. * Tools
mm mm mm mm with KS without KS stroke stroke (insertion bits)
mm mm mm mm
T-899 302 065 210 150 A 1502 M 0,65 (.026) 2,1 (.083) 1,5 (.059) 28,0 (1.102) 12,9 (.508) 7,4 (.291) 3,5 (.138) 4,4 (.173) BIT-GKS-899 M-B
T-899 305 065 280 150 A 1502 M 0,65 (.026) 2,8 (.110) 1,5 (.059) 28,7 (1.130) 13,6 (.535) 7,4 (.291) 3,5 (.138) 4,4 (.173) BIT-GKS-899 M-B
Step Probes
GKS ... M
T-899 305 065 400 150 A 1502 M 0,65 (.026) 4,0 (.158) 1,5 (.059) 29,9 (1.177) 14,8 (.583) 7,4 (.291) 3,5 (.138) 4,4 (.173) BIT-GKS-899 M-B
T-899 305 070 400 150 A 1502 M 0,70 (.028) 4,0 (.158) 1,5 (.059) 29,9 (1.177) 14,8 (.583) 7,4 (.291) 3,5 (.138) 4,4 (.173) BIT-GKS-899 M-B
T-899 305 065 270 150 A 1502 MG 0,65 (.026) 2,7 (.106) 1,5 (.059) 27,1 (1.067) 12,0 (.472) 5,9 (.232) 2,0 (.079) 2,75 (.110) BIT-GKS-899 M-B
T-899 305 065 340 150 A 1502 MG 0,65 (.026) 3,4 (.134) 1,5 (.059) 27,8 (1.095) 12,7 (.500) 5,9 (.232) 2,0 (.079) 2,75 (.110) BIT-GKS-899 M-B
rotating GKS
VF / Non-
Mechanical data Materials
Working stroke: 3,5 mm (.138) Plunger: Steel or BeCu, gold-plated Recommended screw-in torque:*
Maximum stroke: 4,4 mm (.173) Barrel: Brass, gold-plated Min.: 2 cNm / Max.: 3 cNm
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated
RF Test Probes
Dipole-GKS
Ordering example Series Tip Tip style Tip-Ø Tip length Disk-Ø Plating Spring force Collar Special
Assorted
materials (1/100 mm) (1/100 mm) (1/100 mm) A = Gold (dN) height designation
GKS
Test probe: T 8 9 9 3 0 2 0 6 5 2 1 0 1 5 0 A 1 5 0 2 M
Accessories
B
C
E
A
[0,067]
Available tip styles T-112 M
B
M 1,6 1,65 2,3 1 C C
0,063 0,065 0,091 SW0,039
1,7 A
Material
Further versions
Plating
E
[0,067] Tip style
T-112 M M 1,6 1,65 2,3 1 C
A ∅ ∅ (inch)
B
0,063 25,50,065 0,091 0,039
7,5 B A C
1,004 D 0,295
SW 1,7 3 02 A
T-112 M T-112 M
E
[0,067] ∅ s. tbl.
M 1,6 25,5 1,65 2,3 7,5
1 BC
0,063 1,004
0,065 D 0,091 0,295
0,039 A T-112 / 912 M
with KS-112 ... M 3 05 A
T-112 M 1,3 C ∅ s. tbl.
M 1,6 1,65 2,3 0,051 T-112 / 912 M
25,5 7,5 B
0,063 0,065 0,091 A with KS-112 ... M 05
1,004 0,295
D 1,3 3 G A
C *
T-912 MT-912 M M 1,6 1,65 2,3 0,051 ∅ s. tbl.
0,063 25,50,065 0,091 7,5 B A
1,004 0,295 T-112 / 912 M * Special designation “G” at end of part number
D with KS-112 ... M
T-912 M
1,3
25,5 7,5 BC
M 1,6 1,65 2,3 0,051
1,004 0,295
Mechanical 0,063
data 0,065 D Materials
0,091 A
Available tip styles T-912 M
Working stroke: 4,0 mm (.157) Plunger: BeCu, gold-plated
T-912 M
Maximum stroke: 25,5 5,0 mm (.197) Barrel: Brass, gold-plated
Material
Further versions
Plating
7,5 B Tip style
Spring force at work.1,004
stroke: D 1,5 N (5.4oz)
0,295 Spring: Steel, gold-plated ∅ ∅ (inch)
Alternative: 0,6 N (2.1oz); 0,8 N (2.9oz); or stainless steel (MC on request)
2,25 N (8.1oz); 3,0 N (10.8oz); 3 02 A
5,0 N (18.1oz) ∅ s. tbl.
Note:
Operating temperature The T-112 M / T-912 M is screwed into
3 05 A
Standard: -40° up to +80° C KS-112 M, see page 125. ∅ s. tbl.
Electrical data
Current rating: 5-8A Recommended screw-in torque:*
Ri typical: < 20 mW Min.: 3 cNm / Max.: 5 cNm
A B C D E * Tool
Part number Tip-Ø Tip length Disk-Ø Total length Install. height (insertion bits)
mm (inch) mm (inch) mm (inch) mm (inch) with KS mm (inch)
T-912 302 050 150 210 A 1502 M 0,5 (.020) 1,5 (.059) 2,1 (.083) 34,5 (1.358) 9,2 (.362) BIT-T-912 M
T-112 302 065 300 100 A 1502 M 0,65 (.026) 3,0 (.118) 1,0 (.039) 36,0 (1.417) 10,7 (.421) BIT-GKS-112 M-B
T-912 302 070 150 210 A 1502 M 0,7 (.028) 1,5 (.059) 2,1 (.083) 34,5 (1.358) 9,2 (.362) BIT-T-912 M
T-112 302 070 200 180 A 1502 M 0,7 (.028) 2,0 (.079) 1,8 (.071) 35,0 (1.378) 9,7 (.382) BIT-GKS-112 M-B
T-912 302 070 200 210 A 1502 M 0,7 (.028) 2,0 (.079) 2,1 (.083) 35,0 (1.378) 9,7 (.382) BIT-T-912 M
T-112 302 080 320 180 A 1502 M 0,8 (.031) 3,2 (.126) 1,8 (.071) 36,2 (1.425) 10,9 (.429) BIT-GKS-112 M-B
T-912 302 080 320 210 A 1502 M 0,8 (.031) 3,2 (.126) 2,1 (.083) 36,2 (1.425) 10,9 (.429) BIT-T-912 M
T-912 302 100 170 250 A 1502 M 1,0 (.039) 1,7 (.067) 2,5 (.098) 34,7 (1.366) 9,4 (.370) BIT-T-912 M
T-912 302 100 180 250 A 1502 M 1,0 (.039) 1,8 (.071) 2,5 (.098) 34,8 (1.370) 9,5 (.374) BIT-T-912 M
T-912 302 100 200 210 A 1502 M 1,0 (.039) 2,0 (.079) 2,1 (.083) 35,0 (1.378) 9,7 (.382) BIT-T-912 M
T-912 302 100 200 250 A 1502 M 1,0 (.039) 2,0 (.079) 2,5 (.098) 35,0 (1.378) 9,7 (.382) BIT-T-912 M
T-112 302 100 250 180 A 1502 M 1,0 (.039) 2,5 (.098) 1,8 (.071) 35,5 (1.398) 10,2 (.402) BIT-GKS-112 M-B
T-912 302 100 250 210 A 1502 M 1,0 (.039) 2,5 (.098) 2,1 (.083) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
T-112 302 100 300 180 A 1502 M 1,0 (.039) 3,0 (.118) 1,8 (.071) 36,0 (1.417) 10,7 (.421) BIT-GKS-112 M-B
T-912 302 100 300 210 A 1502 M 1,0 (.039) 3,0 (.118) 2,1 (.083) 36,0 (1.417) 10,7 (.421) BIT-T-912 M
T-912 302 100 300 250 A 1502 M 1,0 (.039) 3,0 (.118) 2,5 (.098) 36,0 (1.417) 10,7 (.421) BIT-T-912 M
T-112 302 100 320 200 A 1502 M 1,0 (.039) 3,2 (.126) 2,0 (.079) 36,2 (1.425) 10,9 (.429) BIT-GKS-112 M-B
T-112 302 100 330 230 A 1502 M 1,0 (.039) 3,3 (.130) 2,3 (.091) 36,3 (1.429) 11,0 (.433) BIT-GKS-112 M
T-912 302 100 330 230 A 1502 M 1,0 (.039) 3,3 (.130) 2,3 (.091) 36,3 (1.429) 11,0 (.433) BIT-T-912 M
T-112 302 100 350 250 A 1502 M 1,0 (.039) 3,5 (.138) 2,5 (.098) 36,5 (1.437) 11,2 (.441) BIT-GKS-112 M
T-912 302 100 350 250 A 1502 M 1,0 (.039) 3,5 (.138) 2,5 (.098) 36,5 (1.437) 11,2 (.441) BIT-T-912 M
T-112 302 102 318 245 A 1502 M 1,02 (.039) 3,18 (.126) 2,45 (.098) 36,18 (1.425) 10,88 (.429) BIT-GKS-112 M
T-912 302 120 120 250 A 1502 M 1,2 (.047) 1,2 (.047) 2,5 (.098) 34,2 (1.347) 8,9 (.350) BIT-T-912 M
T-112 302 120 200 190 A 1502 M 1,2 (.047) 2,0 (.079) 1,9 (.075) 35,0 (1.378) 9,7 (.382) BIT-GKS-112 M-B
T-912 302 120 200 210 A 1502 M 1,2 (.047) 2,0 (.079) 2,1 (.083) 35,0 (1.378) 9,7 (.392) BIT-T-912 M
T-912 302 130 210 250 A 1502 M 1,3 (.051) 2,1 (.083) 2,5 (.098) 35,1 (1.382) 9,8 (.386) BIT-T-912 M
T-112 302 130 300 250 A 1502 M 1,3 (.051) 3,0 (.118) 2,5 (.098) 36,0 (1.417) 10,7 (.421) BIT-GKS-112 M
T-912 302 130 300 250 A 1502 M 1,3 (.051) 3,0 (.118) 2,5 (.098) 36,0 (1.417) 10,7 (.421) BIT-T-912 M
T-912 302 140 160 350 A 1502 M 1,4 (.055) 1,6 (.063) 3,5 (.138) 34,6 (1.362) 9,3 (.366) BIT-T-912 M
T-912 302 150 200 350 A 1502 M 1,5 (.059) 2,0 (.079) 3,5 (.138) 35,0 (1.378) 9,7 (.382) BIT-T-912 M
Information
Product
Further versions available upon request
Standard
GKS
A B C D E
Part number Tip-Ø Tip length Disk-Ø Total length Install. height with * Tool
mm (inch) mm (inch) mm (inch) mm (inch) KS mm (inch) (insertion bit)
T-112 302 150 250 300 A 1502 M 1,5 (.059) 2,5 (.098) 3,0 (.118) 35,5 (1.398) 10,2 (.402) BIT-GKS-112 M
T-912 302 150 250 350 A 1502 M 1,5 (.059) 2,5 (.098) 3,5 (.135) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
E-TYPE
DKS
T-112 305 064 150 150 A 1502 M 0,64 (.024) 1,5 (.059) 1,5 (.059) 34,5 (1.358) 9,2 (.362) BIT-GKS-112 M-B
T-112 305 064 250 150 A 1502 M 0,64 (.024) 2,5 (.098) 1,5 (.059) 35,5 (1.398) 10,2 (.402) BIT-GKS-112 M-B
T-912 305 064 250 250 A 1502 M 0,64 (.024) 2,5 (.098) 2,5 (.098) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
T-112 305 064 300 150 A 1502 M 0,64 (.024) 3,0 (.118) 1,5 (.059) 36,0 (1.417) 10,7 (.421) BIT-GKS-112 M-B
Flying Probe
Bead Probe
T-112 305 064 460 180 A 1502 M 0,64 (.024) 4,6 (.181) 1,8 (.071) 37,6 (1.480) 12,3 (.484) BIT-GKS-112 M-B
T-112 305 065 200 180 A 1502 M 0,65 (.026) 2,0 (.079) 1,8 (.071) 35,0 (1.378) 9,7 (.382) BIT-GKS-112 M-B
T-912 305 065 200 210 A 1502 M 0,65 (.026) 2,0 (.079) 2,1 (.083) 35 (1.378) 9,7 (.382) BIT-T-912 M
T-912 305 065 230 250 A 1502 M 0,65 (.026) 2,3 (.091) 2,5 (.098) 35,3 (1.390) 10,0 (.394) BIT-T-912 M
T-112 305 065 250 180 A 1502 M 0,65 (.026) 2,5 (.098) 1,8 (.071) 35,5 (1.398) 10,2 (.402) BIT-GKS-112 M-B
Fine Pitch
T-912 305 065 250 210 A 1502 M 0,65 (.026) 2,5 (.098) 2,1 (.083) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
T-112 305 065 270 150 A 1502 M 0,65 (.026) 2,7 (.106) 1,5 (.059) 35,7 (1.406) 10,4 (.409) BIT-GKS-112 M-B
T-112 305 065 270 150 A 1502 MG 0,65 (.026) 2,7 (.106) 1,5 (.059) 35,7 (1.406) 10,4 (.409) BIT-GKS-112 M-B
T-912 305 065 300 210 A 1502 M 0,65 (.026) 3,0 (.118) 2,1 (.083) 36,0 (1.417) 10,7 (.421) BIT-T-912 M
T-112 305 065 340 180 A 1502 M 0,65 (.026) 3,4 (.134) 1,8 (.071) 36,4 (1.433) 11,1 (.437) BIT-GKS-112 M-B
Stand. GKS
Metric
T-912 305 065 340 210 A 1502 M 0,65 (.026) 3,4 (.134) 2,1 (.083) 36,4 (1.433) 11,1 (.437) BIT-T-912 M
T-112 305 065 340 300 A 1502 M 0,65 (.026) 3,4 (.134) 3,0 (.118) 36,4 (1.433) 11,1 (.437) BIT-GKS -112 M
T-912 305 065 340 300 A 1502 M 0,65 (.026) 3,4 (.134) 3,0 (.118) 36,4 (1.433) 11,1 (.437) BIT-T-912 M
T-112 305 065 360 180 A 1502 M 0,65 (.026) 3,6 (.142) 1,8 (.071) 36,6 (1.457) 11,3 (.445) BIT-GKS-112 M-B
short / long
T-912 305 065 360 210 A 1502 M 0,65 (.026) 3,6 (.142) 2,1 (.083) 36,6 (1.457) 11,3 (.445) BIT-T-912 M
HSS
T-112 305 065 430 150 A 1502 M 0,65 (.026) 4,3 (.169) 1,5 (.059) 37,3 (1.479) 12,0 (.472) BIT-GKS-112 M-B
T-112 305 065 500 150 A 1502 M 0,65 (.026) 5,0 (.197) 1,5 (.059) 38,0 (1.496) 12,7 (.500) BIT-GKS-112 M-B
T-912 305 080 200 250 A 1502 M 0,8 (.032) 2,0 (.079) 2,5 (.098) 35,0 (1.378) 9,7 (.382) BIT-T-912 M
T-912 305 080 230 250 A 1502 M 0,8 (.032) 2,3 (.091) 2,5 (.098) 35,3 (1.390) 10,0 (.394) BIT-T-912 M
Robust HSS
Dipole HSS
T-112 305 080 280 180 A 1502 M 0,8 (.032) 2,8 (.110) 1,8 (.071) 35,8 (1.409) 10,5 (.413) BIT-GKS-112 M-B
T-112 305 080 280 195 A 1502 M 0,8 (.032) 2,8 (.110) 1,95 (.079) 35,8 (1.409) 10,5 (.413) BIT-GKS-112 M-B
T-912 305 080 280 210 A 1502 M 0,8 (.032) 2,8 (.110) 2,1 (.083) 35,8 (1.409) 10,5 (.413) BIT-T-912 M
T-112 305 080 280 250 A 1502 M 0,8 (.032) 2,8 (.110) 2,5 (.098) 35,8 (1.409) 10,5 (.413) BIT-GKS-112 M
T-912 305 080 280 250 A 1502 M 0,8 (.032) 2,8 (.110) 2,5 (.098) 35,8 (1.409) 10,5 (.413) BIT-T-912 M
T-112 305 080 320 230 A 1502 M 0,8 (.032) 3,2 (.126) 2,3 (.091) 36,2 (1.425) 10,9 (.429) BIT-GKS-112 M
SKS
T-912 305 080 320 230 A 1502 M 0,8 (.032) 3,2 (.126) 2,3 (.091) 36,2 (1.425) 10,9 (.429) BIT-T-912 M
T-112 305 080 320 350 A 1502 M 0,8 (.032) 3,2 (.126) 3,5 (.138) 36,2 (1.425) 10,9 (.429) BIT-GKS-112 M
T-912 305 080 320 350 A 1502 M 0,8 (.032) 3,2 (.126) 3,5 (.138) 36,2 (1.425) 10,9 (.429) BIT-T-912 M
Step Probes
T-112 305 080 400 180 A 1502 M 0,8 (.032) 4,0 (.158) 1,8 (.071) 37,0 (1.457) 11,7 (.461) BIT-GKS-112 M-B
GKS ... M
T-912 305 080 400 210 A 1502 M 0,8 (.032) 4,0 (.158) 2,1 (.083) 37,0 (1.457) 11,7 (.461) BIT-T-912 M
T-112 305 080 400 250 A 1502 M 0,8 (.032) 4,0 (.158) 2,5 (.098) 37,0 (1.457) 11,7 (.461) BIT-GKS-112 M
T-912 305 080 400 250 A 1502 M 0,8 (.032) 4,0 (.158) 2,5 (.098) 37,0 (1.457) 11,7 (.461) BIT-T-912 M
T-112 305 080 460 250 A 1502 M 0,8 (.032) 4,6 (.181) 2,5 (.098) 37,6 (1.480) 12,3 (.484) BIT-GKS-112 M
rotating GKS
VF / Non-
T-912 305 080 460 250 A 1502 M 0,8 (.032) 4,6 (.181) 2,5 (.098) 37,6 (1.480) 12,3 (.484) BIT-T-912 M
T-912 305 080 530 280 A 1502 M 0,8 (.032) 5,3 (.209) 2,8 (.110) 38,3 (1.508) 13,0 (.512) BIT-T-912 M
T-112 305 100 200 180 A 1502 M 1,0 (.039) 2,0 (.079) 1,8 (.071) 35,0 (1.378) 9,7 (.382) BIT-GKS-112 M-B
T-912 305 100 200 210 A 1502 M 1,0 (.039) 2,0 (.079) 2,1 (.083) 35,0 (1.378) 9,7 (.382) BIT-T-912 M
T-912 305 100 250 300 A 1502 M 1,0 (.039) 2,5 (.098) 3,0 (.118) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
RF Test Probes
Dipole-GKS
T-912 305 100 260 210 A 1502 M 1,0 (.039) 2,6 (.102) 2,1 (.083) 35,6 (1.402) 10,3 (.406) BIT-T-912 M
T-912 305 100 260 230 A 1502 M 1,0 (.039) 2,6 (.102) 2,3 (.091) 35,6 (1.402) 10,3 (.406) BIT-T-912 M
T-112 305 100 260 250 A 1502 M 1,0 (.039) 2,6 (.102) 2,5 (.098) 35,6 (1.402) 10,3 (.406) BIT-GKS-112 M
T-912 305 100 260 250 A 1502 M 1,0 (.039) 2,6 (.102) 2,5 (.098) 35,6 (1.402) 10,3 (.406) BIT-T-912 M
T-912 305 100 350 250 A 1502 M 1,0 (.039) 3,5 (.138) 2,5 (.098) 36,5 (1.402) 11,2 (.441) BIT-T-912 M
PKS
PSK
T-112 305 100 420 180 A 1502 M 1,0 (.039) 4,2 (.165) 1,8 (.071) 37,2 (1.465) 11,9 (.496) BIT-GKS-112 M-B
T-912 305 100 420 210 A 1502 M 1,0 (.039) 4,2 (.165) 2,1 (.083) 37,2 (1.465) 11,9 (.496) BIT-T-912 M
T-112 305 100 490 180 A 1502 M 1,0 (.039) 4,9 (.193) 1,8 (.071) 37,9 (1.492) 12,6 (.496) BIT-GKS-112 M-B
T-912 305 100 490 210 A 1502 M 1,0 (.039) 4,9 (.193) 2,1 (.083) 37,9 (1.492) 12,6 (.496) BIT-T-912 M
T-912 305 100 600 250 A 1502 M 1,0 (.039) 6,0 (.236) 2,5 (.098) 39,0 (1.535) 13,7 (.539) BIT-T-912 M
Assorted
GKS
T-912 305 120 220 250 A 1502 M 1,2 (.047) 2,2 (.087) 2,5 (.098) 35,2 (1.386) 9,9 (.390) BIT-T-912 M
T-912 305 120 250 250A 1502 M 1,2 (.047) 2,5 (.098) 2,5 (.098) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
T-912 305 140 160 320 A 1502 M 1,4 (.055) 1,6 (.063) 3,2 (.126) 34,6 (1.362) 9,3 (.366) BIT-T-912 M
T-912 305 140 350 250 A 1502 M 1,4 (.055) 3,5 (.138) 2,5 (.098) 36,5 (1.437) 11,2 (.441) BIT-T-912 M
Accessories
T-912 305 140 350 280 A 1502 M 1,4 (.055) 3,5 (.138) 2,8 (.110) 36,5 (1.437) 11,2 (.441) BIT-T-912 M
T-912 305 150 250 300 A 1502 M 1,5 (.059) 2,5 (.098) 3,0 (.118) 35,5 (1.398) 10,2 (.402) BIT-T-912 M
Tools
B
[0,118] C
C
T-113 M M2 2,65 3,6 SW 3 1,8
Material
Further versions
Plating
A
E
0,079 0,104 0,142 [0,118]
0,071 A
B
Tip style
M2 18
2,65 3,6 8,31,8 BC
C ∅ ∅ (inch)
0,079 0,709
0,104 0,142 0,327
0,071 A A
T-113 M
B
D
E
C
18 8,3 B 3 02 A
T-113 M T-113 M
0,709 0,327
E
D ∅ s. tbl.
18 8,3 B
0,709 0,327
D
3 05 A
Material
T-888 M 0,709 0,327 Further versions
Plating
D T-113 M / T-888 M Tip style
18 8,3 B with KS-113...M2 ∅ ∅ (inch)
T-888 M
Mechanical data 0,709 D
0,327 Materials
02
Working stroke: 18 4,0 mm8,3
(.158)B Plunger: BeCu, gold-plated 3 *
A
0,709 0,327 ∅ s. tbl.
Maximum stroke: D 5,0 mm (.197) Barrel: Brass, gold-plated
Spring forces at work. str.: 1,5 N (5,4oz) Spring: Steel, gold-plated
02
altern. T-113 M: 0,3 N (1.1oz); or stainless steel (MC on request) 3 ** A
0,6 N (2.2oz); 1,0 N (3.6 oz); 2,25 N ∅ s. tbl.
(8.1oz); 3,0 N (10.8oz); 5,0 N (18.1oz)
altern. T-888 M: 3,0 N (10.8oz) Note: 3 05 A
∅ s. tbl.
The T-113 M / T-888 M is screwed into
Electrical data KS-113 M, see page 128. * ∅ A ≤ 2,5 mm
Current rating: 5-8A ** ∅ A ≥ 3,5 mm (screw-in only with tool BIT-T-912 M )
Ri typical: < 30 mW *** See table below
A B C D E
Part number Tip-Ø Tip length Disk-Ø Total length Install. height with *** Tool
mm (inch) mm (inch) mm (inch) mm (inch) KS mm (inch) (insertion bit)
T-113 302 100 300 350 A 1502 M 1,0 (.039) 3,0 (.118) 3,5 (.138) 29,3 (1.154) 11,5 (.453) BIT-GKS-113 M
T-888 302 100 300 350 A 1502 M 1,0 (.039) 3,0 (.118) 3,5 (.138) 29,3 (1.154) 11,5 (.453) BIT-T-888 M-3
T-113 302 130 270 470 A 1502 M 1,3 (.051) 2,7 (.106) 4,7 (.185) 29,0 (1.142) 11,2 (.441) BIT-T-113 M
T-888 302 130 270 470 A 1502 M 1,3 (.051) 2,7 (.106) 4,7 (.185) 29,0 (1.142) 11,2 (.441) BIT-T-888 M
T-888 302 130 300 470 A 1502 M 1,3 (.051) 3,0 (.118) 4,7 (.185) 29,3 (1.154) 11,5 (.453) BIT-T-888 M
T-113 302 130 360 470 A 1502 M 1,3 (.051) 3,6 (.142) 4,7 (.185) 29,9 (1.177) 12,1 (.476) BIT-T-113 M
T-888 302 130 360 470 A 1502 M 1,3 (.051) 3,6 (.142) 4,7 (.185) 29,9 (1.177) 12,1 (.476) BIT-T-888 M
T-113 302 130 530 470 A 1502 M 1,3 (.051) 5,3 (.209) 4,7 (.185) 31,6 (1.244) 13,8 (.543) BIT-T-113 M
T-888 302 130 530 470 A 1502 M 1,3 (.051) 5,3 (.209) 4,7 (.185) 31,5 (1.240) 13,7 (.539) BIT-T-888 M
T-113 302 130 580 470 A 1502 M 1,3 (.051) 5,8 (.228) 4,7 (.185) 32,1 (1.264) 14,3 (.563) BIT-T-113 M
T-888 302 130 580 470 A 1502 M 1,3 (.051) 5,8 (.228) 4,7 (.185) 32,0 (1.260) 14,2 (.559) BIT-T-888 M
T-113 302 140 100 350 A 1502 M 1,4 (.055) 1,0 (.039) 3,5 (.138) 27,3 (1.074) 9,5 (.374) BIT-GKS-113 M
T-888 302 140 100 350 A 1502 M 1,4 (.055) 1,0 (.039) 3,5 (.138) 27,3 (1.074) 9,5 (.374) BIT-T-888 M
T-113 302 140 170 350 A 1502 M 1,4 (.055) 1,7 (.067) 3,5 (.138) 28,0 (1.102) 10,2 (.402) BIT-GKS-113 M
T-888 302 140 170 350 A 1502 M 1,4 (.055) 1,7 (.067) 3,5 (.138) 28,0 (1.102) 10,2 (.402) BIT-T-888 M
T-113 302 140 200 350 A 1502 M 1,4 (.055) 2,0 (.079) 3,5 (.138) 28,3 (1.114) 10,5 (.413) BIT-GKS-113 M
T-888 302 140 200 350 A 1502 M 1,4 (.055) 2,0 (.079) 3,5 (.138) 28,3 (1.114) 10,5 (.413) BIT-T-888 M-3
T-113 302 140 240 350 A 1502 M 1,4 (.055) 2,4 (.095) 3,5 (.138) 28,7 (1.130) 10,9 (.429) BIT-GKS-113 M
T-888 302 140 240 350 A 1502 M 1,4 (.055) 2,4 (.095) 3,5 (.138) 28,7 (1.130) 10,9 (.429) BIT-T-888 M
T-113 302 140 300 350 A 1502 M 1,4 (.055) 3,0 (.118) 3,5 (.138) 29,3 (1.154) 11,5 (.453) BIT-GKS-113 M
T-888 302 140 300 350 A 1502 M 1,4 (.055) 3,0 (.118) 3,5 (.138) 29,3 (1.154) 11,5 (.453) BIT-T-888 M
T-113 302 140 320 250 A 1502 M 1,4 (.055) 3,2 (.126) 2,5 (.098) 29,5 (1.161) 11,7 (.461) BIT-GKS-113 M-B
T-113 302 170 220 300 A 1502 M 1,7 (.067) 2,2 (.087) 3,0 (.118) 28,5 (1.122) 10,7 (.421) BIT-GKS-113 M-B
T-113 302 170 220 350 A 1502 M 1,7 (.067) 2,2 (.087) 3,5 (.138) 28,5 (1.122) 10,7 (.421) BIT-GKS-113 M
T-888 302 170 220 350 A 1502 M 1,7 (.067) 2,2 (.087) 3,5 (.138) 28,5 (1.122) 10,7 (.421) BIT-T-888 M
T-888 302 180 140 450 A 1502 M 1,8 (.071) 1,4 (.055) 4,5 (.177) 27,7 (1.091) 9,9 (.390) BIT-T-888 M
T-113 302 180 150 450 A 1502 M 1,8 (.071) 1,5 (.059) 4,5 (.177) 27,8 (1.095) 10,0 (.394) BIT-T-113 M
T-888 302 180 150 450 A 1502 M 1,8 (.071) 1,5 (.059) 4,5 (.177) 27,8 (1.095) 10,0 (.394) BIT-T-888 M
T-113 302 180 160 350 A 1502 M 1,8 (.071) 1,6 (.063) 3,5 (.138) 27,9 (1.098) 10,1 (.398) BIT-GKS-113 M
T-888 302 180 160 350 A 1502 M 1,8 (.071) 1,6 (.063) 3,5 (.138) 27,9 (1.098) 10,1 (.398) BIT-T-888 M-3
T-888 302 180 200 470 A 1502 M 1,8 (.071) 2,0 (.079) 4,7 (.185) 28,3 (1.114) 10,5 (.413) BIT-T-888 M
T-888 302 180 220 350 A 1502 M 1,8 (.071) 2,2 (.087) 3,5 (.138) 28,5 (1.122) 10,7 (.421) BIT-T-888 M-3
Information
Product
Further versions available upon request
Screw-in Step Probes
Standard
GKS
A B C D E
Part number Tip-Ø Tip length Disk-Ø Total length Install. height *** Tool
mm (inch) mm (inch) mm (inch) mm (inch) with KS mm (inch) (insertion bit)
T-888 302 180 420 470 A 1502 M 1,8 (.071) 4,2 (.165) 4,7 (.185) 30,5 (1.201) 12,7 (.500) BIT-T-888 M
T-888 302 180 500 470 A 1502 M 1,8 (.071) 5,0 (.197) 4,7 (.185) 31,3 (1.232) 13,5 (.532) BIT-T-888 M
E-TYPE
DKS
T-113 302 180 580 470 A 1502 M 1,8 (.071) 5,8 (.228) 4,7 (.185) 32,1 (1.264) 14,3 (.563) BIT-T-113 M
T-888 302 180 580 470 A 1502 M 1,8 (.071) 5,8 (.228) 4,7 (.185) 32,1 (1.264) 14,3 (.563) BIT-T-888 M
T-888 302 220 180 350 A 1502 M 2,2 (.087) 1,8 (.071) 3,5 (.138) 28,1 (1.106) 10,3 (.406) BIT-T-888 M-3
Flying Probe
T-888 302 220 200 350 A 1502 M 2,2 (.087) 2,0 (.079) 3,5 (.138) 28,3 (1.114) 10,5 (.413) BIT-T-888 M-3
Bead Probe
T-113 302 230 180 350 A 1502 M 2,3 (.091) 1,8 (.071) 3,5 (.138) 28,1 (1.106) 10,3 (.406) BIT-GKS-113 M
T-113 302 230 200 350 A 1502 M 2,3 (.091) 2,0 (.079) 3,5 (.138) 28,3 (1.114) 10,5 (.413) BIT-GKS-113 M
T-888 302 250 120 470 A 1502 M 2,5 (.098) 1,2 (.048) 4,7 (.185) 27,5 (1.083) 9,7 (.382) BIT-T-888 M
T-888 302 250 200 470 A 1502 M 2,5 (.098) 2,0 (.079) 4,7 (.185) 28,3 (1.114) 10,5 (.413) BIT-T-888 M
Fine Pitch
T-888 302 250 220 470 A 1502 M 2,5 (.098) 2,2 (.087) 4,7 (.185) 28,5 (1.122) 10,7 (.421) BIT-T-888 M
T-888 302 250 300 470 A 1502 M 2,5 (.098) 3,0 (.118) 4,7 (.185) 29,3 (1.154) 11,5 (.453) BIT-T-888 M
T-888 302 370 350 500 A 1502 M 3,7 (.146) 3,5 (.138) 5,0 (.197) 29,8 (1.173) 12,0 (.472) BIT-T-912 M
T-888 302 370 550 500 A 1502 M 3,7 (.146) 5,5 (.217) 5,0 (.197) 31,8 (1.252) 14,0 (.551) BIT-T-912 M
Stand. GKS
Metric
T-888 302 400 100 500 A 1502 M 4,0 (.158) 1,0 (.039) 5,0 (.197) 27,3 (1.075) 9,5 (.374) BIT-T-912 M
T-888 302 400 130 500 A 1502 M 4,0 (.158) 1,3 (.051) 5,0 (.197) 27,6 (1.087) 9,8 (.386) BIT-T-912 M
T-888 302 400 170 500 A 1502 M 4,0 (.158) 1,7 (.067) 5,0 (.197) 28,0 (1.102) 10,2 (.402) BIT-T-912 M
T-113 302 400 200 500 A 1502 M 4,0 (.158) 2,0 (.079) 5,0 (.197) 28,3 (1.114) 10,5 (.413) BIT-T-113 M
short / long
T-888 302 400 200 500 A 1502 M 4,0 (.158) 2,0 (.079) 5,0 (.197) 28,3 (1.114) 10,5 (.413) BIT-T-912 M
HSS
T-113 305 080 150 300 A 1502 M 0,8 (.032) 1,5 (.059) 3,0 (.118) 27,8 (1.095) 10,0 (.394) BIT-GKS-113 M-B
T-888 305 080 150 300 A 1502 M 0,8 (.032) 1,5 (.059) 3,0 (.118) 27,8 (1.095) 10,0 (.394) BIT-T-888 M-3
T-113 305 080 250 300 A 1502 M 0,8 (.032) 2,5 (.098) 3,0 (.118) 28,8 (1.134) 11,0 (.433) BIT-GKS-113 M-B
Robust HSS
Dipole HSS
T-888 305 080 250 300 A 1502 M 0,8 (.032) 2,5 (.098) 3,0 (.118) 28,8 (1.134) 11,0 (.433) BIT-T-888 M-3
T-113 305 080 280 300 A 1502 M 0,8 (.032) 2,8 (.110) 3,0 (.118) 29,1 (1.146) 11,3 (.445) BIT-GKS-113 M-B
T-888 305 080 280 300 A 1502 M 0,8 (.032) 2,8 (.110) 3,0 (.118) 29,1 (1.146) 11,3 (.445) BIT-T-888 M-3
T-113 305 080 300 300 A 1502 M 0,8 (.032) 3,0 (.118) 3,0 (.118) 29,3 (1.154) 11,5 (.445) BIT-GKS-113 M-B
T-888 305 080 300 300 A 1502 M 0,8 (.032) 3,0 (.118) 3,0 (.118) 29,3 (1.154) 11,5 (.445) BIT-T-888 M-3
SKS
T-113 305 100 280 350 A 1502 M 1,0 (.039) 2,8 (.110) 3,5 (.138) 29,1 (1.146) 11,3 (.445) BIT-GKS-113 M
T-888 305 100 280 350 A 1502 M 1,0 (.039) 2,8 (.110) 3,5 (.138) 29,1 (1.146) 11,3 (.445) BIT-T-888 M-3
T-113 305 100 400 350 A 1502 M 1,0 (.039) 4,0 (.158) 3,5 (.138) 30,3 (1.193) 12,5 (.492) BIT-GKS-113 M
Step Probes
GKS ... M
T-888 305 100 400 350 A 1502 M 1,0 (.039) 4,0 (.158) 3,5 (.138) 30,3 (1.193) 12,5 (.492) BIT-T-888 M-3
T-113 305 140 100 350 A 1502 M 1,4 (.055) 1,0 (.039) 3,5 (.138) 27,3 (1.075) 9,5 (.374) BIT-GKS-113 M
T-888 305 140 100 350 A 1502 M 1,4 (.055) 1,0 (.039) 3,5 (.138) 27,3 (1.075) 9,5 (.374) BIT-T-888 M-3
T-113 305 140 170 320 A 1502 M 1,4 (.055) 1,7 (.067) 3,2 (.126) 28,0 (1.102) 10,2 (.402) BIT-GKS-113 M
rotating GKS
VF / Non-
T-888 305 140 170 320 A 1502 M 1,4 (.055) 1,7 (.067) 3,2 (.126) 28,0 (1.102) 10,2 (.402) BIT-T-888 M-3
T-888 305 140 200 350 A 1502 M 1,4 (.055) 2,0 (.079) 3,5 (.138) 28,3 (1.114) 10,5 (.413) BIT-T-888 M-3
T-113 305 140 240 350 A 1502 M 1,4 (.055) 2,4 (.095) 3,5 (.138) 28,7 (1.130) 10,9 (.429) BIT-GKS-113 M
T-888 305 140 240 350 A 1502 M 1,4 (.055) 2,4 (.095) 3,5 (.138) 28,7 (1.130) 10,9 (.429) BIT-T-888 M-3 RF Test Probes
Dipole-GKS
T-888 305 140 270 350 A 1502 M 1,4 (.055) 2,7 (.106) 3,5 (.138) 29,0 (1.142) 11,2 (.441) BIT-T-888 M-3
T-113 305 140 320 350 A 1502 M 1,4 (.055) 3,2 (.126) 3,5 (.138) 29,5 (1.161) 10,7 (.421) BIT-GKS-113 M
T-888 305 140 320 350 A 1502 M 1,4 (.055) 3,2 (.126) 3,5 (.138) 29,5 (1.161) 11,7 (.461) BIT-T-888 M-3
T-113 305 140 330 350 A 1502 M 1,4 (.055) 3,3 (.130) 3,5 (.138) 29,6 (1.165) 11,8 (.465) BIT-GKS-113 M
T-888 305 140 330 350 A 1502 M 1,4 (.055) 3,3 (.130) 3,5 (.138) 29,6 (1.165) 11,8 (.465) BIT-T-888 M-3
PKS
PSK
T-113 305 140 400 350 A 1502 M 1,4 (.055) 4,0 (.158) 3,5 (.138) 30,3 (1.193) 12,5 (.492) BIT-GKS-113 M
T-888 305 140 400 350 A 1502 M 1,4 (.055) 4,0 (.158) 3,5 (.138) 30,3 (1.193) 12,5 (.492) BIT-T-888 M-3
T-113 305 150 400 350 A 1502 M 1,5 (.059) 4,0 (.158) 3,5 (.138) 30,3 (1.193) 12,5 (.492) BIT-GKS-113 M
T-888 305 150 400 350 A 1502 M 1,5 (.059) 4,0 (.158) 3,5 (.138) 30,3 (1.193) 12,5 (.492) BIT-T-888 M-3
Assorted
GKS
T-113 305 170 220 330 A 1502 M 1,7 (.067) 2,2 (.087) 3,3 (.130) 28,5 (1.120) 10,7 (.421) BIT-GKS-113 M
T-888 305 170 220 330 A 1502 M 1,7 (.067) 2,2 (.087) 3,3 (.130) 28,5 (1.120) 10,7 (.421) BIT-T-888 M-3
T-113 305 180 140 400 A 1502 M 1,8 (.071) 1,4 (.055) 4,0 (.158) 27,7 (1.091) 9,9 (.390) BIT-GKS-113 M
Accessories
T-888 305 180 140 400 A 1502 M 1,8 (.071) 1,4 (.055) 4,0 (.158) 27,7 (1.091) 9,9 (.390) BIT-T-888 M-3
T-113 305 180 300 400 A 1502 M 1,8 (.071) 3,0 (.118) 4,0 (.158) 29,3 (1.154) 11,5 (.453) BIT-GKS-113 M
T-888 305 180 300 400 A 1502 M 1,8 (.071) 3,0 (.118) 4,0 (.158) 29,3 (1.154) 11,5 (.453) BIT-T-888 M-3
Tools
IN
D
NTE
Material
Further versions
Plating
E
PAT
Tip style
IN
·
∅ ∅ (inch)
GUN
Ordering example
Test probe (opening 2,1 to 2,4 mm): T 7 8 5 3 6 7 2 0 0 7 0 0 4 0 0 A 9 9 0 2 M
Test probe (opening 2,7 to 3,0 mm): T 7 8 5 3 6 7 2 6 0 6 0 0 4 0 0 A 9 9 0 2 M
Test probe (opening 3,1 to 3,4 mm): T 7 8 5 3 6 7 3 0 0 6 0 0 5 0 0 A 9 9 0 2 M
Receptacle: K S - 3 1 3 3 0 M2
Standard
GKS
Non-rotating Test Probes
E-TYPE
DKS
Flying Probe
Bead Probe
Push-back Probes
Fine Pitch
VF 4 144
in the correct position and cannot be pushed back. For this VF 5 145
test, push-back probes with a spring force of up to 34 N are
used. Non-rotating Probes
Stand. GKS
Push-back probes are usually installed in test modules in GKS-710 146
Metric
cable test benches. The probes are designed with a conti- GKS-746 M 147
nuous plunger. During the test, the push-back probe is GKS-747 M 148
GKS-803 M 149
pressed against the contact sheet. If the contact sheet stays
GKS-714 150
inScale 1:1 (mm)
short / long
the correct position, the plunger makes a downwards
GKS-098 150
HSS
stroke movement. This achieves contact with the test probe GKS-098 M 151
or switching probe which is installed below which can, in VK-541 93
100 turn, confirm the correct position of the contact sheet. HKF-617 94
KK-541 95
Robust HSS
Dipole HSS
90 In combination with switching probes featuring plastic tip
styles, voltage-free tests are possible.
SKS
70 Only this enables tests be performed without damaging the
plug connector components.
60 During assembly, these probes are mounted in the correct
position. Non-rotating test probes are designed to have
Step Probes
GKS ... M
forcibly-guided plungers, which make rotation impossible.
50
40
rotating GKS
Scale 1:1 (mm)
VF / Non-
30
100
20
RF Test Probes
Dipole-GKS
90
10
5 POS-NR. BENENNUNG
80
Millimetereinteilung
POS-NR. BENENNUNG
1 Katalog
GKS-710 220 100 A
Millimetereinteilung
2
0
1507 Katalog
1 Katalog 3 GKS-746 320 150 050 A
1502 M Katalog
GKS-746 M
GKS-747 M
GKS-803 M
GKS-098 M
PKS
PSK
GKS-714
70
3002 M Katalog
VF 25
VF 4
VF 5
4 Katalog
5 VF5-320 180 A 096 34
60 Katalog
-20
Assorted
GKS
50
-30
40
Accessories
-40
Note:
30 See page 118 for overview
-50 and comparison table.
20
Shown without KS - other installation heights available
-60
Tools
141
141
10
VF 25 Grid:
≥ 2,54 mm
Push-back Probe ≥ 100 Mil
Installation height with KS: 40,5 mm (1.594)
Recommended stroke: 5,0 mm (.197)
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 0,9 [.035] gold = 10 N (36 oz.) ø 2,1 [.083] ø 2,2 [.087] s.tbl. 2 03 ∅ 2,20 A
(.087)
VF 25
2,5
29 A
7,5 [.295] 0,9 [.035] 4,5 [.177] 10 [.394] 0,5 [.020] 2 * 0,8 258
38 [1.496]
1,9
69,5 [2.736] 29 A
2 * 0,3 193
silver = 15 N (54 oz.)
VF 25
ø 1,95 [.077]
ø 2,1 [.083]
FH-VF 25
7 [.276]
40,5 (1.594)
Note:*
The flat surface on the plunger tip is
aligned with the flat surface on the
rear of the plunger.
Assembly Notice:**
The patented design allows the test
probe (consisting of plunger and
spring) to be easily exchanged when
necessary, as follows:
Installation height
Installation height: 40,5 mm (1.594) • press the plunger into the recep-
tacle until it reaches its limit
• turn the plunger 90°
Mechanical data Materials • release the plunger
Working stroke: 5,0 mm (.197) Plunger: Steel, gold-plated
Maximum stroke: 6,0 mm (.236) Spring: Steel, gold-plated In order to stabilise the test probe and
Spring force at work. stroke: 10 N (36oz); Receptacle: Bronze, gold-plated to avoid damage to the receptacle
15 N (54oz) during mounting and dismounting, we
Interchangeable stroke: > 6,0 mm (.236) recommend that either an additional
guide plate be inserted underneath, or
Electrical data Mounting hole size that the guide bush FH-VF 25 be atta-
Current rating: 5 A in CEM1 and FR4: ∅ 2,00 mm (.0787) ched to the end of the recepatcle after
Ri typical: < 50 mW mounting, and subsequently soldered
to secure it.
Operating temperature
Standard: -40° up to +80° C
Test probe: V F 2 5 2 2 9 1 9 3 A 1 5 0
Receptacle: K S - V F 2 5
Guide bush:** F H - V F 2 5
Information
Grid:
Product
≥ 3,00 mm
≥ 120 Mil Push-back Probe
Install. height with KS: 40,5/44,5/46,5 mm (1.595/1.752/1.831)
Recommended stroke: 5,0 mm (.197)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
1,50 (.059)
DKS
SW 0,6 [.024] M2 [.079] ø 2,6 [.102] SW 2,2 [.087] ø 1 [.039] ø s.tbl. 2 02 A 1,80 (.071)
∅ 2,30 3,00 (.118)
(.091)
VF 3
7 [.276] 16,3 [.642] 6,3 [.248] 2,20 (.087)
2 03 A 3,00 (.118)
Flying Probe
Bead Probe
5,8 [.228] 12,7 [.500] ∅ 1,90
(.075)
69,7 [2.744]
Fine Pitch
2,70 (.106)
2 06 A 3,00 (.118)
16,3 [.642] C ∅ 2,00
B (.079)
7 [.276] 5,8 [.228] E
VF 3 220 ...
øA
F 20
(see table) 2 * A
see
B C table
ø 2,5 [.098] ø 2,7 [.106]
Stand. GKS
Metric
KS-VF 3
5,7 [.224]
34 [1.339]
short / long
HSS
Robust HSS
Dipole HSS
A B C D E F
D (s. tbl.)
Part No. Tip-Ø Width of Length of Installation Tip height Total length
mm spade in spade in height with in mm mm (inch)
(inch) mm mm (inch) KS in mm (inch)
(inch) (inch)
SKS
VF3 220 250 080 A 405 xx 2,5 (.098) 0,8 (.031) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
VF3 220 250 050 A 405 xx 2,5 (.098) 0,5 (.020) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
VF3 220 250 150 A 405 xx 2,5 (.098) 1,5 (.059) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
VF3 220 190 050 A 405 xx 1,9 (.075) 0,5 (.020) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
Step Probes
GKS ... M
VF3 220 190 050 A 465 xx 1,9 (.075) 0,5 (.020) 12,0 (.472) 46,5 (1.831) 18,7 (.736) 75,7 (2.980)
VF3 220 190 080 A 405 xx 1,9 (.075) 0,8 (.031) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
VF3 220 400 060 A 445 xx 4,0 (.160) 0,6 (.024) 10,0 (.394) 44,5 (1.752) 16,7 (.657) 73,7 (2.902)
VF3 220 220 120 A 405 xx 2,2 (.087) 1,2 (.047) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
rotating GKS
VF / Non-
VF3 220 270 080 A 405 xx 2,7 (.106) 0,8 (.031) 6,0 (.236) 40,5 (1.594) 12,7 (.500) 69,7 (2.744)
VF3 220 250 080 A 465 xx 2,5 (.098) 0,8 (.031) 12,0 (.472) 46,5 (1.831) 18,7 (.736) 75,7 (2.980) Installation height
Installation height with KS: see table
Mechanical data Materials
RF Test Probes
Note:*
Dipole-GKS
Ri typical: < 30 mW
Operating temperature
Standard: -40° up to +80° C
Assorted
Ordering example Series Tip Tip style Tip diameter Spade width Plating Installation Spring
GKS
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 1,3 [.051] ø 3 [.118]
SW 0,8 [.031] M2,5 x 0,35 [.098 x .0138] ø 3,6 [.141] SW 2,5 [.098] ø 1,36 [.054] ø s.tbl. 2 02 ∅ 1,80 A 2,00 (.079)
(.071)
VF 4
2 02 ∅ 2,30 A
(.091)
6,9 [.272] 5,8 [.228] 12,5 [.492]
16,5 [.650]
2 03 ∅ 3,00 A 4,00 (.157)
69,5 [2.736] (.118)
øA
20 see A
2 *
B C table
B 6,9 [.272] C
2,5
21 0,80 A
2
Ø
5,8 [.228] E * 0,8 6
VF 4 220 ... (.031)
(see table) 16,5 [.650]
Ø 2,2
23 1,60 A
F 2 * 6
1,6 (.063)
KS-VF 4
5,7 [.224]
34 [1.339]
D (see tbl.)
A B C D E F
Part No. Tip-Ø Width of Length of Installation Tip height Total length
mm spade in spade in height with in mm mm (inch)
(inch) mm mm (inch) KS in mm (inch)
(inch) (inch)
VF4 220 220 130 A 405 15 2,2 (.087) 1,3 (.051) 6,0 (.236) 40,5 (1.594) 12,5 (.492) 69,5 (2.736)
VF4 220 250 080 A 405 15 2,5 (.098) 0,8 (.031) 12,0 (.472) 46,5 (1.831) 18,5 (.728) 75,5 (2.972)
Installation height
VF4 220 300 160 A 405 15 3,0 (.118) 1,6 (.063) 6,0 (.236) 40,5 (1.594) 12,5 (.492) 69,5 (2.736)
Installation height with KS: see table
Information
Grid:
Product
≥ 5,08 mm
≥ 200 Mil Push-back Probe
Installation height with KS: 36,7 mm (1.445)
Recommended stroke: 5,0 / 9,5 mm (.197/ .374)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
SW
SW33[.118]
[.118]
E-TYPE
2,3
DKS
3 20 1,40 A
øø1,8
1,8[.070]
[.070] M3,5
M3,5[.138]
[.138] øø44[.157]
[.157] øø4,6
4,6[.181]
[.181] øø2,3
2,3[.090]
[.090] s.s.tbl.
tbl. 1,4 12 (.055)
2,8
VF
VF55 3 20* 1,50* A
1,5 12 (.059)
Flying Probe
18,3
18,3[.720]
[.720] 14,7
14,7[.579]
[.579] 10
10[.394]
[.394] 12
12[.472]
[.472]
Bead Probe
2,3
96
96[3.780]
[3.780] 3 20 1,60 A
1,6 12 (.063)
2,3
3 20 1,80 A
1,8 12 (.071)
øø4,6
4,6[.181]
[.181] øø4,4
4,4[.173]
[.173] øø4,35
4,35[.171]
[.171]
Fine Pitch
KS-VF
KS-VF55030
030
16,5
16,5[.650]
[.650]
30
30[1.181]
[1.181]
Stand. GKS
Metric
short / long
36,7 [1.445]
HSS
Robust HSS
Dipole HSS
The VF 5 is mounted in the KS-VF5 030
which is pressed into a second plate to
min. 43,8 [1.724]
SKS
VF5-320 150 A 096 with 15 N and 20
N = 10,0 mm (.394)
Note:
Step Probes
The flat surface on the plunger tip is
GKS ... M
aligned with the flat surface on the
rear of the plunger.
Mechanical data
Spring force at Pre-load Working stroke Maximum stroke
work. stroke in mm (inch) in mm (inch) Note:
To identify the spring force, the flat
rotating GKS
VF / Non-
15 N (54oz) 2,7 N (10oz) 9,5 (.374) 10* (.394)/12 (.472) areas for the spanner are marked with
20 N (72oz) 3,6 N (13oz) 9,5 (.374) 10* (.394)/12 (.472) notches:
Ordering example Series Tip Tip style Spade width Plating Total length Spring force
Assorted
GKS
Test probe: V F 5 3 2 0 1 5 0 A 0 9 6 2 0
Receptacle: K S - V F 5 0 3 0
Tools
Material
Plating
Tip styles Install.
Width of height
spade Plating (without
KS)
ø 1,72 [.068] ø 1,3 [.051]
Ø2
15,1 mm
ø 1,65 [.065] ø 2,2 [.087] ø s.tbl. 2 20 1,00 A
(.594)
1 3 (.039)
Ø2
7 [.276] 3 [.118] 2 20 0,50 R 0,40 R 18,1 mm
* 6 A (.713)
0,5 (.020)
5,1 [.201]
35,1 [1.382]
15,1 mm
Ø2
2 21 0,50 A 1,30 A (.594)
3 (.020)
ø 1,68 [.066] ø 1,3 [.051] 0,5
7 [.276] 3 [.118]
5,1 [.201] ∅ 1,30 R 13,1 mm
2 23 (.516)
1,3 (.051)
35,1 [1.382]
Ø
ø 2 [.079] ø 2,2 [.087] 15,1 mm
2
2 26 2,00 A
(.594)
2 2,5 (.079)
KS-712 30
(only usable with * 3 mm longer than standard tip styles
0,2 [.008] GKS-710 ... S)
30 [1.181]
(.236) 6 [.236]
3 [.118]
(.591) 3 (.118)
6
[.713]
18
15
7 [.276]
(.276)
(.276)
7
without KS
Test probe: G K S 7 1 0 2 2 0 1 0 0 R 1 5 0 7
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Screw-in Non-Rotating Test Probe with Continuous Plunger
Installation height with KS: 10,5 mm (.413)
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
ø 1,65 [.065] SW 1,7 [.067] ø 1 [.039]
DKS
3 05 ∅ 0,64 A
ø 0,8 [.031] M 1,6 [.063] ø 2,3 [.091] ø s.tbl. 0,46 [.018] 5 (.025)
SW 0,46 [.018]
3 14 ∅ 2,00 A
GKS-746 ... M (.078)
Flying Probe
Bead Probe
2 [.079] 3,8 [.150]
ø1,1
4,5 [.177] 3 20 ∅ 0,45 A
0,45 1,2 3,8 (.017)
40,2 [1.583]
ø1,5
ø 1,3 [.051] ø 2 [.079] ø 2,2 [.087] 3 20 A
∅ 0,50
0,5 1,2 3,8
(.020)
Fine Pitch
KS-746 23 M
ø2
3 20 A
∅ 0,80
5 [.197] 0,2 [.008] 0,8 1,2 3,8
(.031)
40,7 [1.602]
ø1,5
3 20 A
ø 2,05 [.081] 1,2 3,8 ∅ 1,00
1
(.039)
Stand. GKS
Metric
KS-746 23 M-R
short / long
HSS
Robust HSS
Dipole HSS
(.413)
10,5
SKS
Collar height and installation height
The installation height of the test probe
is determined by the collar height of the
receptacle.
Step Probes
GKS ... M
Collar height Installation height
with KS
Note:
02 10,5 mm (.413) When screwing the test probe into
the receptacle, the plunger is secured
rotating GKS
VF / Non-
against rotation. The flat surface at the
end of the plunger fits into the slot at
Mechanical data Materials the end of the receptacle.
Working stroke: 4,0 mm (.157) Plunger: Steel or BeCu, gold-plated
Maximum stroke: 4,4 mm (.173) Barrel: Brass, gold-plated The assembled unit is then vacuum-
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated
RF Test Probes
sealed and can therefore be used for
Dipole-GKS
Series Tip Tip style Tip diameter Spade width Plating Spring Collar Type
Ordering example
GKS
Test probe: G K S 7 4 6 3 2 0 1 5 0 0 5 0 A 1 5 0 2 M
Receptacle: K S - 7 4 6 2 3 M
Material
Plating
with KS
Tip style
Collar Install.
height height
Continuous Plunger
ø 1,3 (.051) ø 2,5 M3 x 0,35 SW 2,6 ø 2,1
ø2,9
ø 2,9 20,2
SW 0,7 (.028) (.098) (.118 x .0138) (.102) (.083) (.114) 3 29 A 02 (.795)
0,8 6
298
ø4
16,2
3 29 A 02 (.638)
25 2 7 6 0,8 3
(.984) (.079) (.276) (.236) 408
40
GKS-747 329 298 A xx02 M (1.575) ø4
(.157)
25 2 6 3
(.984) (.079) (.236) (.118)
36
GKS-747 329 408 A xx02 M (1.417)
ø 1,3 ø3 ø 3,4
(.051) (.118) (.134)
KS-747 23 M
5 5,2
(.197)
37 (1.457) (.205)
ø 3,05
(.120)
KS-747 23 M-R
(.795)
20,2
(.638)
16,2
3 = BeCu
Test probe: G K S 7 4 7 3 2 9 2 9 8 A 1 5 0 2 M
Receptacle: K S - 7 4 7 2 3 M K S - 7 4 7 2 3 M-R
Information
Grid:
Product
≥ 4,50 mm
≥ 177 Mil Screw-in Test Probe with Continuous Plunger
Installation height with KS: 18,3 mm (.720)
Recommended stroke: 6,4 mm (.252)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
Continuous Plunger 1 02 A
0,8 ø2,5 208
SW 0,95 (.037) M2,5 ø3 ø 3,75 SW 3 ø s. tbl.
ø 1,44 (.057) (.098) (.118) (.148) (.122) 1 02 A
1,6 ø2,5
216
Flying Probe
GKS-803 ... M
Bead Probe
3 02 A
10 (.394) 2 8 (.315) 8 (.315) ∅ 2,30
(.091)
48 (1.890) (.079)
3 06 A
∅ 3,00
(.118)
Fine Pitch
1 ø 3,5 ø 3,75
(.039) (.138) (.148)
KS-803 M2,5
Stand. GKS
0,3
Metric
3,5 (.012)
(.138)
26,5 (1.043)
short / long
HSS
Robust HSS
Dipole HSS
SKS
Collar height and Installation height
Step Probes
GKS ... M
The installation height of the tip is deter- Note:
mined by the collar height. When screwing the test probe into
the receptacle the plunger is secured
Collar height Installation height against rotation. The flat section at the
with KS end of the plunger moves into the slit
at the end of the receptacle.
rotating GKS
02 18,3 mm (.720)
VF / Non-
Mechanical data Materials Note:
Working stroke: 6,4 mm (.252) Plunger: BeCu, gold-plated Plunger tip with flat section: the flat
Maximum stroke: 8,0 mm (.315) Plunger head: BeCu or brass, gold-plated section of the plunger tip is set at 90°
Spring force at work. stroke: 1,5 N (5.4oz); Barrel: Brass, gold-plated to the flat section at the end of the
RF Test Probes
Dipole-GKS
Ordering example
Assorted
Series Tip Tip style Tip diameter Plating Spring force Collar height Type
GKS
Test probe: G K S 8 0 3 3 0 6 3 0 0 A 1 5 0 2 M
Receptacle: K S - 8 0 3 M 2.5
Tools
Material
Plating
tional Dim.
ø 2,65 [.104] ø 3,7 [.146] s.tbl. Tip style
Collar Install.
height height
5
18,8
2 20 R 07 (.740)
7,5 [.295] 0,4 4,5
GKS-714 220 504 ... 504
7 [.276] 11,8 [.465]
33,8 [1.331]
15,8
5
s.tbl. 2 20 R 07 (.622)
1 3
510
ø6
14,8
4,5 [.177] 2 36 R 07 (.583)
GKS-714 220 510 ...
7 [.276] 8,8 [.346] 3 2
630
30,8 [1.213]
s.tbl.
Available tip styles
GKS-714 ... 10
Install. and Func-
Material
Plating
tional Dim.
2 [.079] Tip style
Collar Install.
GKS-714 236 630 ... height height
7 [.276] 7,8 [.307]
29,8 [1.173] 2 22 ∅ 4,00 A 10 22,0
5 (.157)
(.866)
4
GKS-714 ... 10
22,0
continuous plunger ø 2 [.079] 2 23 ∅ 2,00 A 10 (.866)
2 (.079)
ø 1,3 [.051] ø 2,65 [.104] ø 3 [.118] ø s.tbl.
22,0
2 23 ∅ 4,00 A 10 (.866)
4 5 (.157)
Plating
tional Dim.
GKS-098 ... 07 ø 2,25 [.089] Tip style
Collar Install.
ø 3 [.118] ø 3,5 [.138] s. tbl. height height
3
15,5
3 29 R 07 (.610)
0,7 3,5 ∅ 3,00
(.118)
6,5 [.256]
7 [.276] 8,6 [.339]
28,6 [1.126]
Test probe: G K S 7 1 4 2 2 0 5 0 4 R 1 5 0 7
Test probe: G K S 0 9 8 3 2 9 3 0 0 R 1 5 0 7
Lamellar plug for type 714 E10: S E - 5 0 3 (cannot be used with KS)
Information
Grid:
Product
≥ 5,08 mm
≥ 200 Mil Screw-in Non-Rotating Test Probe with Continuous Plunger
Installation height: 15,3 mm (.602)
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
Continuous Plunger
DKS
ø3
M2,5 ø3 (.118) SW3 ø 1,8 3 29 A
(.098) (.118) (.071) ø 3 x 0,7 0,7
(.118 x.028) 300 070
Flying Probe
Bead Probe
3,5 (.138)
Fine Pitch
ø 3,48 ø 3,5 ø 3,8
Stand. GKS
(.137) (.138) (.150)
Metric
KS-098 M2,5
0,25 (.010)
23,7 (.930)
short / long
HSS
Robust HSS
Dipole HSS
15,3
(.602)
SKS
Installation height with KS
Install. height “ML”: 15,3 mm (.602) Note:
Further versions available upon
Step Probes
GKS ... M
request.
GKS-098 ... ML
in KS-098 M2,5 Note:
When screwing the test probe into the
Mechanical data Materials receptacle, the plunger will be secured
rotating GKS
VF / Non-
Working stroke: 4,0 mm (.157) Plunger: BeCu, gold-plated against rotation. The flat surface at the
Maximum stroke: 5,0 mm (.197) Barrel: Brass, gold-plated end of the plunger fits into the slot at
Spring force at work. stroke: 1,5 N (5.4oz); Spring: Steel, gold-plated the end of the receptacle.
3,0 N (10.8oz) Receptacle: Brass, gold-plated
The flat surface on the plunger tip is
RF Test Probes
Dipole-GKS
Electrical data Mounting hole size aligned with the flat surface on the
Current rating: 10 A in CEM1 and FR4: ∅ 3,48 - 3,49 mm rear of the plunger.
Ri typical: < 30 mW (.1370 - .1374)
Recommended screw-in torque:
Operating temperature Min.: 10 cNm / Max.: 20 cNm
Standard: -40° up to +80° C
PKS
PSK
Test probe: G K S 0 9 8 3 2 9 3 0 0 0 7 0 A 1 5 0 2 ML
Receptacle: K S - 0 9 8 M2.5
Accessories
Tools
Dipole test probes and RF test probes are used in various Plug connectors are used to connect a variety of RF com-
industries: They enable precise, accurately repeatable measure- ponents, such as cables and PCB modules. In the automotive
ment of resistance as well as RF performance. industry, plug connectors such as FAKRA or HSD connectors
are used to transmit audio and video signals. U.FL connec-
Using dipole test probes, 4-wire measurements to accu- tors are used in radio modules, among others.
rately determine resistances can be performed. In doing so,
the voltage is measured using the inner conductor and the Mini switches are used to test RF signals which are supplied
current is measured using the outer conductor. by chip antennas or PCB antennas.
RF test probes are used to contact plug connectors, mini PCB test points alow RF signals to be contacted directly on
switches and PCB test points. These are used in the to the PC board. Depending on the nature of the PC board
following way: and application, this is carried out in various ways.
Dipole measurement
PCB layout, switch and plug connector contacting
(Kelvin contact)
152
Information
Product
Contents
Technical Information
Standard
GKS
Scale 1:1 (mm)
E-TYPE
DKS
100
Flying Probe
Bead Probe
90 Dipole GKS
DPS-215 M 156
80 The dipole test probes developed by INGUN are highly DPS-465 M 157
suitable for performing 4-wire measurements thanks to their
Fine Pitch
coaxial design. This allows the voltage to be measured Dipole HFS
70
directly on the contact surface and the resistance to be
determined. Furthermore, it is also possible to perform HFS-010 158
60 connection tests on coaxial plug connectors. HFS-110 159
Stand. GKS
Metric
50 Depending on the application, variable grid sizes, tip styles
and dimensions are available.
Dipole test probes are installed using a receptacle. The con-
40 Standard HFS
short / long
nection is made using either a connector or by soldering on
HSS
the receptacle. HFS-810 (M)
30
HFS-840 (M)
HFS-860 (M)
20 HFS-865
Robust HSS
Dipole HSS
Scale 1:1 (mm)
Short HFS
10
5 HFS-410 (M)
100 HFS-440 (M)
0
DPS-215 M
DPS-465 M
HFS-010
HFS-110
POS-NR. BENENNUNG
SKS
1 Millimetereinteilung
Katalog
90
2 DPS-215 304 027 A
2006 M Katalog
DPS-465 306 100 A
Flange HFS
-10
3 4006 M Katalog
4 HFS-010 354 050 A
2006 A Katalog
HFS-110 306 115 A
5 3006 A Katalog
HFS-409
80 HFS-821
Step Probes
GKS ... M
-20
HFS-822
70 HFS-823
-30 HFS-852
HFS-856
60
rotating GKS
HFS-864
VF / Non-
-40
Shown without KS - other installation heights available
50
-50
To optimally fulfill the requirements in radio frequency Plug Connectors RF Test Probes
Dipole-GKS
-80
0
GKS
-10
Accessories
-20 Note:
See next page for overview
-30 and comparison table
Tools
-40 153
153
Technical Information
Image
1.0/2.3 x x x x
7/16 HFS-864
BMA x x x x
BNC x x x x
F HFS-409
FAKRA x x x x
FME x x x x
GT13 x x x x
GT16 x x x x
HDMI PS-HDMI
HSD x
IEC HFS-409
MBX x x x x x
MCX x x x x x
MM5829 x
MMBX x x x x x
MMCX x x x x
MMPX x
Plug connectors
MX-series x
N x x x
PC3.5 x
P-SMP x
QMA x
RJ-series PS-RJ
R-SMA x
R-TNC x x x x
SMA x x x x x x
SMB x x x x
SMC x x x x
SMP x x x x x
SMP-L x
SMP-MAX x
SMPX x
SSMP x
TAE PS-TAE
U.FL x x x x x x x x
USB-series x PS-USB
W.-FL x x
W.-FL2 x x
X.FL x x
MM8030, MM8130, MM8430 x x x x
switches
MS-156, MS-180 x x x
RF
All RF test probes available from INGUN are listed in the table above. The optimal test solution can be selected based on the
test point (plug connection, RF switch or PCB layout) and the frequency required.
154
The new RF-Probes Catalogue
Optimal test solutions for your challenging analog and digital RF applications.
tions
lu
o
in
sting s
No. 1
der PrüF
te
Te
chnik in
RF-Probes
Plug connector, Miniature Switch
and PcB contacting
Besides general mechanical and electrical
data, INGUN provides scattering parameter
graphs for several product types.
catalogue 5.1
DPS-215 M Grid:
≥ 2,54 mm
Coaxial Dipole Probe ≥ 100 Mil
Installation height with KS: 10,2 mm (.402)
Recommended stroke: 4,0 mm (.157)
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
DPS-215 ... M
Material
Further versions
Plating
Tip style
ø 0,27 [.011] ∅ ∅ (inch)
3 06 A
∅ 2,00
(. 079)
KS-215 M1,6
0,2 [.008]
29,5 [1.161]
KS-215 M1,6-F
0,2 [.008]
42,9 [1.689]
10,4
10,2
9,75
KS-215 M1,6-F-R
(with knurl)
DPS-215...06 M
with KS-215 M1,6 F
Test probe: D P S 2 1 5 3 0 4 0 2 7 A 2 0 0 6 M
Receptacles: K S – 2 1 5 M 1 ,6 K S – 2 1 5 M 1 ,6 - F
K S – 2 1 5 M 1 ,6 - F - R
Information
Grid:
Product
≥ 3,50 mm
≥ 140 Mil Coaxial Dipole Probe
Installation height with KS: 10,4 mm (.395)
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
inner conductor
SW 2,6 [.102]
Material
Further versions
Plating
ø 0,7 [.028] M2,5 [.098] ø 2,65 [.104] ø 3,2 [.126] ø 2,26 [.089] Tip-styles
∅ ∅∅ (inch)
E-TYPE
DKS
3 02 ∅ 0,50 A
(.020)
7 [.276] 2 [.079] 8,2 [.323]
44,8 [1.764] 3 06 ∅ 1,00 A
ø s.tbl. ø 1,7 [.067] (.039)
Flying Probe
Bead Probe
3 51 ∅ 0,50 A
(.020)
ø3 ø 3,2 3 54 ∅ 1,00 A
ø 1,2 ø 2 ø2 (.039)
[.047] [.079] [.079] ø 3 [.118] ø 3,2 [.126] M2,5 [.098] [.118] [.126]
Fine Pitch
Available tip styles
3 [.118] 9 [.354] 5 [.197] 0,2 [.008] outer conductor
13 [.512]
Material
Further versions
21,2 [.835] 21,2 [.835]
Plating
Tip-styles
SE 215 for
Stand. GKS
∅ ∅ (inch)
Metric
usage with DPS-465 M KS-465 M2,5 E05 KS-465 M2,5
ø 1,7 3 02 A
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126] ∅ 2,26
(.089)
short / long
KS-465 M2,5-F
3 06 A
HSS
∅ 2,26
4,2 [.165] 0,2 [.008] (.089)
38,1 [1.500]
ø 3,05 [.120]
Robust HSS
Dipole HSS
KS-465 M2,5-F-R
10,4
10,2
9,75
9,8
(with knurl)
ø 1,7
[.067] ø 2,2 [.087] ø 3 [.118] ø 3,2 [.126]
SKS
4,2 [.165] 5 [.197]
38,1 [1.500]
ø 3,05 [.120]
Step Probes
GKS ... M
KS-465 M2,5 E05-F-R
(with knurl) DPS-465...02 M
with KS-465 M2,5
rotating GKS
Note:
VF / Non-
Working stroke: 4,0 mm (.157) Plunger: BeCu, gold-plated
Maximum stroke: 5,0 mm (.197) Barrel: Brass, gold-plated Recommended screw-in torque:
Spring force at working stroke Spring: Steel, gold-plated Min.: 3 cNm / Max.: 5 cNm.
- outer conductor: 3,0 N (10.7oz) Receptacle: Brass, gold-plated
- inner conductor: 1,0 N (3.6oz) Insulation: PTFE Note:
RF Test Probes
Dipole-GKS
Ordering example Series Tip Tip style Tip diameter Plating Spring force Outer plunger Type
Assorted
3 = BeCu 02)
D P S 4 6 5 3 5 1 0 5 0 A 4 0 0 6 M
Accessories
Test probe:
Receptacles: K S – 4 6 5 M 2 ,5 K S – 4 6 5 M 2 ,5 - F
K S – 4 6 5 M 2 ,5 - F - R
Tools
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
Connection for SE-K11527-50010 MG 075
ø2 ø2,2 ø1,66 ø1,1(.043) ∅ 0,50 A
3 51
(.079) (.087) (.065) ø0,46 (.020)
(.018)
3 54 ∅ 0,50 A
(.020)
9,5
39 (1.535)
(.374)
Lieferbare Kopfformen
40 (1.575)
HFS-010...06 A Available tip styles
ø2,5 ø2,8 outer plunger
(.098) (.110)
02
0,25
26 (1.024) (.010)
KS-010 23
06
10,2
9,75
9,8
HFS-010
with KS-010 23
Operating temperature
Standard: -40 up to +80 °C
3 = BeCu 06)
Test probe: H F S 0 1 0 3 5 1 0 5 0 A 2 0 0 2 A
Receptacle: K S – 0 1 0 2 3
Plug with RF coaxial cable, pre-wired, S E – K 1 1 5 2 7 - 5 0 0 1 0 M G 0 7 5
length 0,75 m (custom length on request):
Information
Grid:
Product
≥ 4,50 mm
≥ 177 Mil Coaxial Dipole Probe/RF-Test Probe, 50 Ω, 700 MHz
Installation height with KS: 9,8 mm (.386)
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
inner conductor
Material
HFS-110......A
A Further versions
Plating
HFS-110 Tip style
with Plug
with Plug Connection
Connection for
for ø3,5 ø3,65 ø2,6 ø1,9(.075)
(.075) ∅ ∅ (inch)
ø3,5 ø3,65 ø2,6 ø1,9
SE-RG178-50110 MG MG 075
075
E-TYPE
SE-RG178-50110 (.138) (.144) (.102)
(.138) (.144) (.102) øø s.tbl.
s.tbl.
DKS
3 01 ∅ 0,50 A
(.020)
(.079)
(.079) 22 7,5(.295)
7,5 (.295) 3 02 ∅ 0,50 A
35 (1.378)
(1.378) (.020)
Flying Probe
35
Bead Probe
Type A
Type A ø3
ø3 3 03 ∅ 1,15 A
(.118)
(.118) (.045)
3 04 ∅ 1,15 A
(.045)
Fine Pitch
27 (1.063)
27 (1.063)
3 05 ∅ 1,15 A
SE-RG178-50110 MG
SE-RG178-50110 MG 075
075 (.045)
3 06 ∅ 1,15 A
(.045)
Stand. GKS
HFS-110...
HFS-110 ...B
B
Metric
with Solder
with Solder Connection
Connection 3 07 ∅ 1,00 A
Solder Connection
Solder Connection 22 (.039)
Solder Connection
Connection 11 ø3,5
ø3,5 ø3,65
ø3,65 ø2,6
ø2,6 øø s.tbl.
s.tbl.
Solder
(.138)
(.138) (.144)
(.144) (.102)
(.102) 3 08 ∅ 1,15 A
(.045)
short / long
HSS
2,5 (.098)
(.098) (.079)
(.079) 22 7,5(.295)
7,5 (.295)
2,5
34,5(1.358)
34,5 (1.358) Available tip styles
outer plunger
10,4
10,2
9,75
9,8
Type B
Type B ø4
ø4 ø4,3
ø4,3
(.158) (.169)
Robust HSS
(.158) (.169)
Dipole HSS
02
KS-110 23
KS-110 23
88 0,3
0,3 06
23,3(.917)
(.917) (.315)
(.315) (.012)
(.012)
23,3
SKS
HFS-110 ...A
Lieferbare Kopfformen
with KS-110 23
Step Probes
Mechanical data Materials
GKS ... M
Working stroke: 4,0 mm (.157) Plunger: BeCu, gold-plated Note:
Maximum stroke: 5,0 mm (.197) Barrel: Brass, gold-plated The inner conductor is fixed in the
Spring force at working stroke Spring: Steel, gold-plated probe, and therefore cannot be
- outer conductor: 3,0 N (10.8oz) Receptacle: Brass, gold-plated changed.
- inner conductor: 1,5 N (5.4oz) Insulation: Teflon
rotating GKS
VF / Non-
Electrical data Mounting hole size
Frequency range: up to 700 MHz with receptacle: ∅ 3,98 - 3,99 mm
Current rating: 3A (.1567 - .1571)
Ri typical: < 20 mW without receptacle: ∅ 3,50 mm (.1378) RF Test Probes
Dipole-GKS
Operating temperature
Standard: -40° up to +80 °C
PKS
PSK
conductor
Test probe: H F S 1 1 0 3 0 4 1 1 5 A 3 0 0 2 A
Accessories
Receptacle: K S – 1 1 0 2 3
Plug for HFS-110 ... A with RF coaxial cable pre-
wired, length 0,75 m (custom length on request): S E – R G 1 7 8 - 5 0 1 1 0 M G 0 7 5
Tools
Pneumatic test probes (PKS) are used in all industries and barrel) and the plunger extends when pressure is applied.
a multitude of applications. These include individual contac- PKS can be operated in groups or individually, allowing indi-
ting of single test points, activation of switches, contacting vidual test sequences to be created. A wide range of acces-
of difficult-to-access test points, or creation of interface sories are available for doing so.
blocks.
The installation and electrical connection of PKS is made
A big advantage is that individual contact points can be using either a standard receptacle, or a quick-exchange
contacted without the need for a complete test fixture. The receptacle.
pneumatic test probes rest in the home position (plunger in
Side contacting /
contacting difficult-to-reach positions
Button activation
160
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Pneumatic Test Probes
Pneumatic test probes are operated by pressurised air. In the Press-in Probes
resting position the plunger is inside the barrel and is moved
Fine Pitch
PKS-171 163
outwards when pressurised air is applied. The spring inside PKS-200 164
returns the plunger back to the home position after the PKS-220 165
pressurised air is removed. PKS-299 166
PKS-300 167
Stand. GKS
1.
1. Compressed airKolben
Druckluft 0 bar, 0 bar,eingefahren,
plunger at home position
Grundstellung
PKS-399 168
Metric
3
2 4
1 5
0 6
PKS-420 169
Scale 1:1 (mm)
Screw-in Probes
short / long
2.
2. Compressed airKolben
Druckluft 6 bar, 6 bar,ausgefahren,
plunger extended at working position
Arbeitsstellung
3
PKS-171 M 170
HSS
2 4
1 5
0 6
Robust HSS
Dipole HSS
using either a standard receptacle, or a quick-exchange
80 receptacle. When using a quick-exchange receptacle, the Pneumatic
cable is either soldered or clipped directly onto the recep- Switching Probes
70 tacle, and the pressurised air hose is connected to the tail PSK-350 M 173
end of the receptacle. This is a real advantage in terms of
SKS
maintenance, as probes can be exchanged without the need
60
for rewiring, or replacing the hose connection. Our pneumatic test
probes are designed Accessories PKS 174 - 175
50 The available contact force of pneumatic test probes
Step Probes
as incomplete ma-
GKS ... M
behaves in completely the opposite way from that of chines and meet the
40 spring-loaded test probes. This means that the further the stipulations of the
plunger is moved outwards, the lower the contact force be- Machine Directive
comes (spring force of the recoil spring works against this). 2006/42/EG.
rotating GKS
30
VF / Non-
20
RF Test Probes
Scale 1:1 (mm)
Dipole-GKS
10
5
0
100
PKS-171 M
PKS-355 M
PKS-388 M
PSK-350 M
PKS-171
PKS-200
PKS-220
PKS-299
PKS-300
PKS-399
PKS-420
-10
PKS
PSK
90
POS-NR.
-20 1 M
K
80 2 P
0
Assorted
-30
GKS
70
-40 Note:
60
See next page for overview
Accessories
-60
40
Tools
-70 161
30 161
Technical Information
Possible installation
Contact heights with recpetacle
Pneumatic Grid Working Max. Min.
Max. rated force - wor- (KS) (mm)
test probe Series size stroke stroke length PKS Page
current (A) king stroke
version (≥ mm) (mm) (mm) home (mm)
(N) extended
position
PKS-171 1.91 6 10 1–2 0.3 5.8 11.8 40 163
PKS-200 2.54 6 10 1–2 0.6 5.9 11.9 40/42.7 164
PKS-220 2.54 6 10 2–3 0.8 5.9 11.9 40/42.7 165
Press-in
PKS-299 3.5 12 / 12.3 20 / 20.3 3 / 10 1.7 5.9 (5.6) 17.9 54.1 / 54.4 166
probes
PKS-300 3.5 6 10 3 / 10 1.1 / 1.5 5.9 11.9 40/42.7 167
PKS-399 4.5 12 / 12.2 20 / 20.2 3 / 10 3.7 / 4.2 5.9 (5.7) 17.9 54.2 / 55 168
PKS-420 4.5 6 10 3 / 10 3.7 / 4.2 5.9 11.9 42.7 169
PKS-171 M 2.54 6 10 1–2 0.3 5.8 11.8 32.5 170
Screw-in
PKS-355 M 3.5 6 10 1–2 0.6 5.7 11.7 29.8 171
probes
PKS-388 M 4.5 12 20 3 / 10 1.7 6.1 18.1 43.1 172
Pneumatic
switching PSK-350 M 3.5 6 10 1–2 0.6 5.7 11.7 36.2 173
probe
Accessories
Accessories - - - - - - - - 174/175
PKS
162
PKS 171
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil Pneumatic Test Probes
Installation height with KS: 5,8 mm (.228)
Recommended stroke: 6,0 mm (.236)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
(.622)
DKS
15,8
2 04* ∅ 1,00 A
ø1,7 øs.tbl. (.039)
Connection for Hose NW 1 ø1,5
(.228)
(.059) (.067)
5,8
2 14* ∅ 0,50 A
(.020)
Flying Probe
Bead Probe
7 5,5
(.276) (.217) 3 19 ∅ 1,50 A
40 (1.575)
(.059)
PKS-171 Type A ø1,8 ø2,0 PKS-171 ...A
(.071) (.079) in
KS-171 2 91* ∅ 1,00 A
KS-171 (.039)
11 0,3
Fine Pitch
* Diameter of collar: 1,3 mm (.051)
(.433) (.012)
27,5 (1.083)
Stand. GKS
Metric
PKS-171
Contact Force
short / long
F[N] (Ounces)
HSS
Disp. Range (±20%)
Robust HSS
Dipole HSS
0,3 (1.1)
0,23 (.8)
0,24 (.9)
Stroke [mm]
(inch)
1 2 3 4 5 6 7 8 9 10
(.039)(.079)(.118)(.157)(.197)(.236)(.276)(.315)(.354)(.394)
Operating Max. Stroke
SKS
Stroke
Step Probes
GKS ... M
Mechanical data Materials
rotating GKS
Warning:
VF / Non-
Switch. path/work. stroke: 6,0 mm (.236) Plunger: Steel, gold-plated
Maximum stroke: 10,0 mm (.394) Barrel: Brass, gold-plated Do not solder the cable to the crimp
Cont. force at work.stroke: 0,3 N (1.1oz) Restoring spring: Steel, gold-plated points of the receptacle.
Operating medium: Compressed air Receptacle: Brass, gold-plated
(filtered, oil-free) O-rings: Perbunan Note:
RF Test Probes
Dipole-GKS
Operating pressure: 6 bar (86 psi) The assembly in grid size 1,91 mm (75
Mil) is only possible up to a double
Electrical data Mounting hole size row, and then only without use of
Current rating: 1-2A with receptacle KS-171: receptacles.
Ri typical: < 30 mW ∅ 1,79 - 1,80 mm (.0705 - .0709)
without receptacle: ∅ 1,49 mm (.0587) Note:
PKS
PSK
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type
GKS
Test probe: P K S 1 7 1 2 0 4 1 0 0 A 0 3 0 2 A
Receptacle: K S – 1 7 1
Tools
Material
Further versions
Plating
Connection for Hose NW 1 ø2 ø2,2 øs.tbl. Tip style
(.079) (.087) ∅ ∅ (inch)
01 ∅ 1,50 R
2 ***
7 5,5 (.059)
(.276) (.217)
40 (1.575)
04
PKS-200 Type A 2 ** ∅ 1,30 R
ø2,4 ø2,6 ** (.051)
(.094) (.102)
06
2 ** ∅ 1,00 A
(.039)
10,6 0,4
(.417) (.016) 33
27,5 (1.083) 2 ** ∅ 1,30 A
** (.051)
KS-200
91
2 ∅ 1,00 A
Connection for Hose NW 1 *
(.039)
Connection KL-300 ø2 ø2,2
(.079) (.087) Collar diameter:
* = 1,20 mm (.047) ** = 1,30 mm (.051)
*** = 1,50 mm (.059) **** 1,80 mm (.071)
9,7 5,5
(.382) (.217)
42,7 (1.681)
PKS-200 Type B
3 (.118)
KL-300 8
(.315)
PKS-200
Contact Force
F[N] (Ounces)
Test probe: P K S 2 0 0 2 0 1 1 5 0 R 0 6 0 2 A
Receptacle: K S – 2 0 0
Information
Grid:
Product
≥ 2,54 mm
≥ 100 Mil Pneumatic Test Probes
Installation height with KS: 5,9 mm (.232)
Recommended stroke: 6,0 mm (.236)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Connection for Hose NW 1 ø2,3 øs.tbl. Further versions
Plating
ø2,2
(.087) (.091) Tip style
∅ ∅ (inch)
E-TYPE
01
DKS
7 5,5 2 ** ∅ 1,50 R
(.276) (.217) (.059)
40 (1.575)
PKS-220 Type A
ø3 ø3,2 3 03 ∅ 2,00 R
(.118) (.126) (.079)
Flying Probe
Bead Probe
04
2 ∅ 1,30 R
*
10,6 0,4 (.051)
(.417) (.016)
27,5 (1.083)
05
2 *** ∅ 1,00 A
KS-220 (.039)
Fine Pitch
Connection for Hose NW 1
2 06 ∅ 2,50 A
Connection KL-300 ø2,2 ø2,3 (.098)
(.087) (.091)
3 06 ∅ 2,00 R
(.079)
9,7 5,5
Stand. GKS
(.382) (.217)
Metric
42,7 (1.681) 2 07 ∅ 2,00 R
(.079)
PKS-220 Type B
91
2 ** ∅ 1,00 N
** (.039)
short / long
Collar diameter:
HSS
3 (.118)
* = 2,00 mm (.079) ** = 1,50 mm (.059)
KL-300 8
*** = 1,30 mm (.051) **** 1,20 mm (.047)
(.315)
PKS-220
Robust HSS
Dipole HSS
Contact Force
F[N] (Ounces)
1,5 (5.4)
Disp. Range (±20%)
1,2 (4.3)
0,96 (3.5)
1,0 (3.6)
SKS
0,8 (2.8)
Stroke [mm]
(inch)
Step Probes
GKS ... M
2 4 6 8 10
(.079) (.157) (.236) (.315) (.394)
Warning:
Operating Max. Stroke
Stroke Do not solder the cable to the crimp
points of the receptacle.
rotating GKS
Mechanical data Materials
VF / Non-
Working stroke: 6,0 mm (.236) Plunger: Steel or BeCu, Note:
Maximum stroke: 10,0 mm (.394) rhodium- or gold-plated The assembly in grid size 2,54 mm
Cont. force at work.stroke: 0,8 N (2.9oz) Barrel: Brass, gold-plated (100 Mil) is only possible up to a dou-
Operating medium: Compressed air Restoring spring: Steel, gold-plated ble row, and then only without use of
(filtered, oil-free) Receptacle: Brass, gold-plated receptacles and KL-300. The receptacle RF Test Probes
Dipole-GKS
Operating pressure: 6 bar (86 psi) O-rings: Perbunan and KL-300 can be used from grid size
3,5 mm (140 Mil) upwards.
Electrical data Mounting hole size
Current data: 2-3A with receptacle: ∅ 2,98 - 2,99 mm
Note:
Ri typical: < 30 mW (.1173 - .1177)
Pneumatic accessories and general
without receptacle: ∅ 2,20 mm (.0866)
Operating temperature instructions shown on page 174.
PKS
PSK
Standard: 0° up to +80 °C
3 = BeCu
Test probe: P K S 2 2 0 2 0 1 1 5 0 R 0 8 0 2 A
Accessories
Receptacle: K S – 2 2 0
Clip connection with solder terminal K L – 3 0 0
for Series 220:
Tools
Material
Further versions
Plating
Tip style
Connection for Hose NW 1 ø3 ø3,2 øs.tbl. ∅ ∅ (inch)
(.118) (.126)
Connection KL-300
01 ∅ 2,00 R
2 **
(.079)
PKS-299 Type B 04
2 ** ∅ 1,30 R 2,00 (.079)
ø3,4 ø3,6 (.051)
(.134) (.142)
15*
2 ∅ 2,00 A
(.079)
Material
Further versions
Plating
3 (.118) Tip style
KL-300 8 ∅ ∅ (inch)
(.315)
01 ∅ 1,50 R
2 ***
(.059)
PKS-299
04
Contact Force 2 *** ∅ 1,50 R
F[N] (Ounces) (.059)
Test probe: P K S 2 9 9 2 0 1 2 0 0 R 1 7 0 2 B
Receptacle: K S – 2 9 9
Information
Grid:
Product
≥ 3,50 mm
≥ 140 Mil Pneumatic Test Probes
Installation height with KS: 5,9 mm (.232)
Recommended stroke: 6,0 mm (.236)
Standard
GKS
Mounting and functional dimensions Available tip styles
Connection for Hose NW 1 ø3 ø3,2 øs.tbl.
Material
Further versions
Plating
(.118) (.126) Tip style
∅ ∅ (inch)
E-TYPE
01
DKS
2 ∅ 2,00 R
7 5,5 (.079)
(.276) (.217)
40 (1.575)
04
PKS-300 Type A 2 ** ∅ 1,30 R 2,00 (.079)
(.051)
ø3,4 ø3,6
Flying Probe
Bead Probe
(.134) (.142)
05
2 ∅ 2,50 R 1,30 (.051)
KS-300 (.098) **
10,6 0,4
06 2,50 (.098)
(.417) (.016) 2 ** ∅ 1,30 A
3,50 (.138)
27,5 (1.083) (.051)
Fine Pitch
Connection for Hose NW 1 15
2 ∅ 2,00 A
*
(.079)
Connection KL-300 ø3 ø3,2
(.118) (.126)
33
2 ** ∅ 1,30 A
(.051)
Stand. GKS
91
Metric
9,7 5,5 2 ** ∅ 1,30 A
(.382) 3 (.118) (.051)
(.217)
42,7 (1.681)
KL-300 8
(.315) * pressed-in HM-tip, installation height 6,5 mm (.256)
** Collar diameter: 2,0 mm (.079)
PKS-300 Type B
short / long
HSS
PKS-300
Contact Force
F[N] (Ounces) Disp. Range (±20%)
2,0 (7.2)
1,9 (6.9) 1,8 (6.5)
Robust HSS
Dipole HSS
1,5 (5.4)
1,25 (4.5)
1,2 (4.3)
1,0 (3.6)
Warning:
0,5 (1.8) Do not solder the cable to the crimp
SKS
points of the receptacle.
Stroke [mm]
(inch)
1 2 3 4 5 6 7 8 9 10
(.079) (.157) (.236) (.315) (.394) Note:
For high current applications up to 10
Step Probes
Operating Max. Stroke
GKS ... M
Stroke A, order with special designation”AH”
(terminal “A”) resp. “BH” (terminal
Mechanical data Materials “B”).
Working stroke: 6,0 mm (.236) Plunger: Steel, rhodium- or gold-plated
Maximum stroke: 10,0 mm (.394) Barrel: Brass, gold-plated
Contact force at work.stroke: 1,1 N (4.0oz) Restoring spring: Steel, gold-plated Note:
rotating GKS
VF / Non-
or 1,5 N (5.4oz) Receptacle: Brass, gold-plated The receptacle can be used from grid
Operating medium: Compressed air O-rings: Perbunan size 4,00 mm (160 Mil) upwards.
(filtered, oil-free)
Operating pressure: 6 bar (86 psi) Note:
Pneumatic accessories and general
RF Test Probes
Dipole-GKS
Test probe: P K S 3 0 0 2 0 1 2 0 0 R 1 1 0 2 A
Receptacle: K S – 3 0 0
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
Connection for Hose NW 1
ø4 ø4,2 øs.tbl. 01 ∅ 2,00 R
Connection KL-300 2
(.157) (.165) (.079)
3 02 ∅ 2,50 A
(.098)
9,7 / 10,5 5,5
(.382 / .413) (.217)
54,4 / 55,2 04
2 ** ∅ 1,30 R 2,00 (.079)
(2.142 / 2.173) (.051)
PKS-399 Type 1: with Connection for Hose NW 1
PKS-399 Type 2: with Connection for Hose NW2 (lengths see 2nd value) 2 15* ∅ 2,00 A
(.079)
3 (.118)
0,4 Available tip styles
39,2 (1.543) (.016)
KL-300 8 special versions without collar
(.315) KS-399
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
01 ∅ 1,50 R
PKS-399 2 ***
Contact Force (.059)
F[N] (Ounces)
04
Disp. Range (±20%) 2 *** ∅ 1,50 R
6,0 (21.7)
Note: (.059)
2,0 (7.2)
The plungers of PKS-399
5,0 (18.1)
with tip styles without a 05
3 *** ∅ 1,30 A
4,2 (15.2) collar sit 0.2 mm deeper in (.051)
1,3 (4.7)
the barrel in the home posi-
3,0 (10.8) 1,4 (5.0) *** shaft diameter: 1,50 mm (.059)
tion. This affects the total
2,0 (7.2) length (Type 1: 54.2 mm;
1,0 (3.6) Type 2: 55 mm), the instal-
Stroke [mm] lation height (5.7 mm), the **** Note:
2 4 6 8 10 12 14 16 18 20
(inch)
working stroke (12.2 mm), Tip 01, 15 F = 3,7 N (13.4oz)
(.079) (.236) (.394) (.551) (.709)
and the maximum stroke Tip 02, 04, 05 F = 4,2 N (15.2oz)
Operating Max. Stroke
Stroke (20. 2 mm).
Warning:
Mechanical data Materials Do not solder the cable to the crimp
Working stroke: 12,0 mm (.472) Plunger: Steel or BeCu, points of the receptacle.
Maximum stroke: 20,0 mm (.787) rhodium- or gold-plated
Cont. force at work.stroke: 3,7 N (13.4oz) Barrel: Brass, gold-plated Note:
or 4,2 N (15.2oz)**** Restoring spring: Steel, gold-plated For high current applications up to 10
Operating medium: Compressed air Receptacle: Brass, gold-plated A,order with special designation”1H”
(filtered, oil-free) O-rings: Perbunan (terminal “1”) resp. “2H” (terminal
Operating pressure: 6 bar (86 psi) “2”).
Test probe: P K S 3 9 9 2 0 1 2 0 0 R 3 7 0 2 1
Receptacle: K S – 3 9 9
Information
Grid:
Product
≥ 4,50 mm
≥ 177 Mil Pneumatic Test Probes
Installation height with KS: 5,9 mm (.232)
Recommended stroke: 6,0 mm (.236)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
Connection for Hose NW 1 ∅ ∅ (inch)
E-TYPE
01
DKS
Connection KL-300 ∅ 2,00 R
ø4 ø4,2 2
(.157) (.165) øs.tbl. (.079)
04 ∅ 1,30 R 2,00
2 ** (.079)
(.051)
Flying Probe
Bead Probe
9,7 / 10,5 5,5
1,30
(.382 / .413) (.217) 2 05 ∅ 2,50 R
**
(.051)
42,7 / 43,5 (.098)
(1.681 / 1.713)
06 2,50 (.098)
PKS-420 Type 1: with Connection for Hose NW 1 2 ** ∅ 1,30 A
3,50 (.138)
(.051)
PKS-420 Type 2: with Connection for Hose NW2 (lengths see 2nd value)
Fine Pitch
15
2 ∅ 2,00 A
ø4,5 *
ø4,7 (.079)
(.177) (.185)
33
2 ** ∅ 1,30 A
(.051)
3 (.118)
Stand. GKS
0,4 91
Metric
KL-300 8 2 ** ∅ 1,30 A
27,5 (1.083) (.016) (.051)
KS-420 (.315)
short / long
Disp. Range (±20%)
HSS
5,0 (18.1) 4,8 (17.3)
4,0 (14.5)
3,7 (13.4)
Robust HSS
Dipole HSS
2,0 (7.2)
1,0 (3.6)
Warning:
Stroke [mm]
(inch) Do not solder the cable to the crimp
1 2
(.079)
3 4
(.157)
5 6
(.236)
7 8
(.315)
9 10
(.394) points of the receptacle.
SKS
Operating Max. Stroke
Stroke
Note:
For high current applications up to 10
Mechanical data Materials A, order with special designation”1H”
Working stroke: 6,0 mm (.236) Plunger: Steel, rhodium- or gold-plated
Step Probes
(terminal “1”) resp. “2H” (terminal
GKS ... M
Maximum stroke: 10,0 mm (.394) Barrel: Brass, gold-plated “2”).
Cont. force at work.stroke: 3,7 N (13.4oz) Restoring spring: Steel, gold-plated
or 4,2 N (15.2oz)*** Receptacle: Brass, gold-plated
Operating medium: Compressed air O-rings: Perbunan Note:
(filtered, oil-free) The receptacle can used from grid size
rotating GKS
5,08 mm (200 Mil) upwards.
VF / Non-
Operating pressure: 6 bar (86 psi)
Test probe: P K S 4 2 0 2 0 6 1 3 0 A 4 2 0 2 1
Receptacle: K S – 4 2 0
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
2 14* ∅ 0,50 A
(.020)
1,5 (.276) 5,3
32,5 (1.280) (.209)
3 19 ∅ 1,50 A
PKS-171 ... M (.059)
PKS-171
Contact Force
F[N] (Ounces)
(.622)
15,8
0,4 (1.4) 0,36 (1.3)
(.228)
5,8
0,3 (1.1)
0,23 (.8)
0,24 (.9)
Stroke [mm]
(inch)
1 2 3 4 5 6 7 8 9 10
(.039)(.079)(.118)(.157)(.197)(.236)(.276)(.315)(.354)(.394) PKS-171 ... M
in
Operating Max. Stroke KS-171 AM
Stroke
Operating temperature
Standard: 0° up to +80 °C
Test probe: P K S 1 7 1 2 0 4 1 0 0 A 0 3 0 2 M
Receptacle: K S – 1 7 1 A M
Information
Grid:
Product
≥ 3,5 mm
≥ 140 Mil Screw-in Pneumatic Test Probes
Installation height with KS: 5,7 mm (.224)
Recommended stroke: 6,0 mm (.236)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
Ø2 M2,5 x 0.35 ø3,2 2,2 (.087) ∅ ∅ (inch)
(.079) (.098 x .014) (.126) x 2,6 (.102)
E-TYPE
01
DKS
2 *** ∅ 1,50 R
(.059)
5,2 (.205)
29,8 (1.173) 04
2 ** ∅ 1,30 R
PKS-355 ... M ** (.051)
Flying Probe
Bead Probe
Connection for Hose NW 1 06
2 ** ∅ 1,00 A
Connection KL-300 ø3 ø3,2 (.039)
(.118) (.126)
33
2 ** ∅ 1,30 A
** (.051)
Fine Pitch
0,2 (.008)
9,7 (.382) 11 (.433) 91
2 ∅ 1,00 A
*
(.039)
38,2 (1.504)
KS-355 M - B collar diameter:
* = 1,20 mm (.047) ** = 1,30 mm (.051)
Assembly PKS-355 M with quick-exchange system KS-355 M-B *** = 1,50 mm (.059) **** = 1,80 mm (.071)
Stand. GKS
Metric
5,7 (.224)
43,7 (1.720)
short / long
3 (.118)
HSS
KL-300 8
max. stroke 10 (.315)
(.394)
15,7
(.618)
Contact Force
Robust HSS
Dipole HSS
F[N] (Ounces)
SKS
0,5 (1.8)
0,48 0,35 (1.3)
(1.7)
Stroke [mm]
2 4 6 8 10 (inch)
Step Probes
GKS ... M
(.079) (.157) (.236) (.315) (.394)
Note:
Operating Max.
Stroke Stroke Electrical and pneumatic connections
are performed at the time of customi-
sing only. The exchangeable unit PKS-
Mechanical data Materials 355 M is screwed into the pre- wired,
Working stroke: 6,0 mm (.236) Plunger: Steel, rhodium- or gold-plated pneumatically connected KS-355 M-B
rotating GKS
VF / Non-
Maximum stroke: 10,0 mm (.394) Barrel: Brass, gold-plated receptacle. The test probe can be chan-
Cont. force at work.stroke: 0,6 N (2.2oz) Restoring spring: Steel, gold-plated ged from above. The test fixture must
Operating medium: Compressed air Receptacle: Brass, gold-plated not be opened. The wiring and pneu-
(filtered, oil-free) O-rings: Perbunan matic connections are not affected.
Operating pressure: 6 bar (86 psi)
RF Test Probes
Dipole-GKS
Operating temperature
Recommended screw-in torque:
PKS
PSK
Standard: 0° up to +80 °C
Min.: 10 cNm / Max.: 20 cNm
2 = Steel R = Rhodium
GKS
Test probe: P K S 3 5 5 2 0 1 1 5 0 R 0 6 0 2 M
Accessories
Receptacle: K S – 3 5 5 M-B
Material
Further versions
Plating
(.118) (.138) (.165) (.118) Tip style
∅ ∅ (inch)
01 ∅ 2,00 R
2 **
5,4 (.213) (.079)
43,1 (1.697)
PKS-388 ... M 3 02 ∅ 2,50 A
(.098)
Connection for Hose NW 1
Connection KL-300 ø4 ø4,3 04
2 ** ∅ 1,30 R 2,00 (.079)
(.157) (.169)
(.051)
15*
2 ** ∅ 2,00 A
0,4 (.016) (.079)
9,7 (.382) 11 (.433)
50,7 (1.996) * pressed-in HM-tip,
KS-388 M - 1 installation height with KS: 7,1 mm (.280)
** collar diameter: 2,0 mm (.0799)
Assembly PKS-388 M with quick-exchange system KS-388 M-1 Available tip styles
special versions without collar
Material
Further versions
Plating
(.118) Tip style
6,1 (.240) 3
56,4 (2.220) ∅ ∅ (inch)
KL-300 8
(.315)
01 ∅ 1,50 R
2 ***
max. stroke 20 (.059)
(.787)
26,1 (1.028)
04
2 *** ∅ 1,50 R
(.059)
Contact Force
F[N] (Ounces) 05
3 *** ∅ 1,30 A
Disp. Range (±20%) (.051)
0,5 (1.8)
Note:
Stroke [mm] Electrical and pneumatic connections
(inch)
2 4 6 8 10 12 14 16 18 20 are performed at the time of customi-
(.079) (.236) (.394) (.551) (.709) sing only. The exchangeable unit PKS-
Operating Max. Stroke 355 M is screwed into the pre-wired,
Stroke pneumatically connected KS-355 M-B
receptacle. The test probe can be chan-
Mechanical data Materials ged from above. The test fixture must
Working stroke: 12,0 mm (.472) Plunger: Steel or BeCu, not be opened. The wiring and pneu-
Maximum stroke: 20,0 mm (.787) rhodium- or gold-plated matic connections are not affected.
Cont. force at work. stroke: 1,7 N (6.1oz) Barrel: Brass, gold-plated
Operating medium: Compressed air Restoring spring: Steel, gold-plated Pneumatic accessories and general
(filtered, oil-free) Receptacle: Brass, gold-plated instructions shown on page 174.
Operating pressure: 6 bar (86 psi) O-rings: Perbunan
Note - PKS-388 M and KS-388 M-1:
Electrical data Mounting hole size PKS-388 M are screwed into KS-388
Current rating: 2 - 3 A in CEM1 and FR4: ∅ 4,00 - 4,02 mm M-1 using specialised tools (shown on
10 A (Type “MH”, see note) (.1575 - .1583) page 196).
Ri typical: < 30 mW
Recommended screw-in torque:
Operating temperature Min.: 10 cNm / Max.: 20 cNm
Standard: 0° up to +80 °C
Test probe: P K S 3 8 8 2 0 1 2 0 0 R 1 7 0 2 M
Receptacle: K S – 3 8 8 M-1
Information
Grid:
Product
≥ 3,5 mm
≥ 140 Mil Screw-in Pneumatic Switching Probes (opener)
Installation height with KS: 5,7 mm (.224)
Switch path: 6,0 mm (.236)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
Ø0,45 Ø2 MF 2,5 x 0,35 (.098) ø3,2 2,2 (.087)
(.018) (.079) (.014) (.126) x 2,6 (.102)
E-TYPE
01
DKS
2 *** ∅ 1,50 R
(.059)
Flying Probe
Bead Probe
(.260)
PSK-350 ... M - 6 04
2 ** ∅ 1,30 R
Connection for Hose NW 1 ** (.051)
Fine Pitch
33
2 ** ∅ 1,30 A
** (.051)
Connection for 2nd wire 0,2 (.008)
9,7 (.382) 11 (.433)
38,2 (1.504) 91
2 ∅ 1,00 A
*
KS-350 M - 6 - B (.039)
Stand. GKS
Collar diameter:
Metric
Assembly PSK-350 M with quick-exchange system KS-350 M-6-B * = 1,20 mm (.047) ** = 1,30 mm (.051)
*** = 1,50 mm (.059) **** = 1,80 mm (.071)
short / long
(.315)
HSS
max. stroke 10
(.394)
15,7
(.618)
Functionality:
Robust HSS
Dipole HSS
The pneumatic switching probe
Contact Force
F[N] (Ounces)
PSK 350 is designed as an “opener”.
There is an electric contact between
the pneumatic probe and the terminal
Disp. Range (±20%) of the receptacle in the home position.
1,0 (3.6)
After 6 mm (.236) stroke this connec-
0,72 (2.6)
tion is interrupted.
SKS
0,6 (2.2)
0,5 (1.8)
0,48 0,35 (1.3)
(1.7) Note:
Stroke [mm]
Electrical and pneumatic connections
are performed at the time of customi-
Step Probes
GKS ... M
1 2 3 4 5 6 7 8 9 10 (inch)
(.079) (.157) (.236) (.315) (.394) sing only. The exchangeable unit PKS-
Operating Max. 355 M is screwed into the pre-wired,
Stroke
Stroke pneumatically connected KS-355 M-B
receptacle. The test probe can be chan-
Mechanical data Materials ged from above. The test fixture must
rotating GKS
VF / Non-
Switch. path/work. stroke: 6,0 mm (.236) Plunger: Steel, rhodium- or gold-plated not be opened. The wiring and pneu-
Maximum stroke: 10,0 mm (.394) Barrel: Brass, gold-plated matic connections are not affected.
Cont. force at work.stroke: 0,6 N (2.2oz) Restoring spring: Steel, gold-plated
Operating medium: Compressed air Receptacle: Brass, gold-plated Pneumatic accessories and general
(filtered, oil-free) O-rings: Perbunan instructions shown on page 174). RF Test Probes
Operating pressure: 6 bar (86 psi) Insulation: Peek
Dipole-GKS
2 = Steel R = Rhodium
GKS
3 = CuBe
Example of set-up
and layout: KTP KTP
ST-PZ-010
PS-300-1
PZ-010
PKS
ST-PZ-M5
General notes:
A compressed air hose with a standard width of 1 mm (NW1) or The electrical connection is established by first soldering the wire to
2 mm (NW2) is required to connect pneumatic probes. A range the KL-300 clip, then fixing the clip onto the end of the pneumatic
of adapters (see table below) are offered to establish air feed lines test probe. (Refer to marked positions in the drawings on the pre-
from commercially available compressed air hose NW3 or from vious data sheets).
compressed air distributors with threaded terminals M5. To avoid damage to the ends of the hose, only the recommeded
specialised cutter tool SS-101 should be used
The hose NW1 should only be used for short distances. The larger The various connections plates are controlled using micro-valves.
diameter of 3 mm guarantees good operating pressure. Instead of a micro-valve, a sealing plate (DP-1) can be used to seal
the air outlet holes.
Sealing plate for conn. plate DP-1 2 - Terminal for hose NW 3 VR-200-3
5 2 Dummy plug for distributor ST-PZ-M5
Silencer M3 28574 - 1 Terminal for hose NW 3 VR-300-3
Silencer M5 3981 - 1 Silencer 3981
Information
Product
Standard
GKS
Single Connection Plate (ASP-1) Multi Connection Plate (ASP-2...-10)
MV12/MV24
E-TYPE
DKS
32 (1.260)
ASP-5
27,2 (1.071)
4xM5
21,2 (.835)
MV12/MV24
5 (.197)
A A R P
ASP-1
13
Flying Probe
Bead Probe
(.315) 8
A R
(.512)
3xM3
3
9,5
(.374) 25
19 (.984)
Fine Pitch
(.748)
21,5 (.846)
9,3
25 (.984)
Manual operation
(.512)
(.610)
(.366) 9,3
(.366)
Stand. GKS
Metric
5
(.197)
13
15,5
2 x ø3,5
(.138)
short / long
13 (.512) 3 (.118) (.102) (.413) (.335)
HSS
L2
24,8 (.976) L1
Robust HSS
Dipole HSS
Table of Dimensions for Multi Connection Plate
Number
Valves L1 L2
Ten-fold distributors (PZ-010) T-piece (PT-300-M5) 33,5 (1.319) 27,5 (1.083)
2
SKS
3 44,0 (1.732) 38,0 (1.496)
(.315)
8
Step Probes
GKS ... M
(.472)
7 86,0 (3.386) 80,0 (3.150)
M5
13 8 96,0 (3.780) 90,5 (3.563)
(.512)
9 107,0 (4.213) 101,0 (3.976)
(.551)
M5
G1/8
14
rotating GKS
(.276)
VF / Non-
7
RF Test Probes
Dipole-GKS
(.472)
ø3,6
12
12
10,0 SW13
12
Assorted
G1/8
12
GKS
NW3
10,2 12,5 14,5
21,6
VR-200-2 (.402) VR-300-2 (.492) RD-300-1-2 (.571) VR-PZ-3 (.850)
M5
NW4 G1/8
Spring-loaded test probes can be used directly in assem- Solderable GKS are soldered directly into PC boards without
blies or on PC boards in addition to classic test purposes. the need for receptacles. These probes can be used in similar
Therefore, INGUN probes can be used for a wide variety applications as the short stroke probes, for example, current
of test applications. transfer within an assembly
176
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Assorted Test Probes
Fine Pitch
current of electronic devices and enable a quick assembly GKS-961 179
exchange during maintenance. GKS-761 M 180
GKS-967/967 M 181
Thereby the test probes have a variety of advantages GKS-970 182
Stand. GKS
• Height and tolerance compensation GKS-364 183
Metric
• Compensation of unevenness and parallelism errors GKS-365 184
• Can withstand impacts and vibrations GKS-366 184
• Minimal installation space required
short / long
• High conductivity
Solderable Test Probes
HSS
• Excellent chemical resistance
• Outstanding durability GKS-941 185
GKS-064 185
The short stroke probes can also be installed with a recep- GKS-986 185
Robust HSS
Dipole HSS
tacle to enable easy exchange. Due to the extremely short
design, exchange
Scale 1:1 (mm) solutions for probes installed directly on
the PC board can also be realised without difficulty.
SKS
100
Solderable GKS are soldered directly into PC boards without
the need for receptacles. Care should be taken to ensure the
90 test probe does not overheat during the soldering process, in
Step Probes
GKS ... M
order to avoid damage to the spring.
80 Note: The GKS-967…G probe can also be soldered directly
into PC boards without a receptacle. This is made possible
70 by its closed barrel, which ensures solder cannot penetrate
the probe.
rotating GKS
VF / Non-
60 For quick, reliable assembly of PC boards, it is
possible to pack the test probes in assembly belts.
50 This enables the automatic feeding of parts in the
RF Test Probes
Dipole-GKS
20
Scale 1:1 (mm)
10
Assorted
GKS-761 M
GKS-961
GKS-967
GKS-970
GKS-364
GKS-365
GKS-366
GKS-941
GKS-064
GKS-968
GKS
5
100
0
90 Note:
Accessories
-10
See next page for overview
80 and comparison table.
-20
70 Shown without KS
-30
Tools
177
177
60
-40
Technical Information
178
GKS 961
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil Short-stroke and Charging Test Probes
Installation height with KS: 3,0 mm (.118)
Recommended stroke: 1,0 mm (.039)
Standard
GKS
Mounting and functional dimensions Available tip styles
Further
Material
Plating
versions
Tip style
∅ ∅ (inch)
E-TYPE
DKS
3 05 ∅ 0,50 A
(.020)
Flying Probe
Bead Probe
(.020)
2,3 (.091)
(.008) 0,2
2,8 (.110)
(.287) 7 (.276)
Fine Pitch
GKS-961
Stand. GKS
2,3 (.091)
Metric
2 (.008) 0,2
2,8 (.110)
(.079)
7,3 (.287) 7 (.276)
KS-961 35 GKS-961
short / long
HSS
Robust HSS
Dipole HSS
SKS
Step Probes
GKS ... M
rotating GKS
Mechanical data Materials
VF / Non-
Working stroke: 1,0 mm (.039) Plunger: BeCu, gold-plated
Maximum stroke: 1,3 mm (.051) Barrel: Brass, gold-plated
Spring force at work. stroke: 0,6 N (2.2oz) Spring: Stainless steel, gold-plated
Receptacle: Brass, gold-plated RF Test Probes
Dipole-GKS
Operating temperature
Standard: -100° up to +200° C
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
Assorted
2 = Steel
3 = BeCu
Test probe: G K S 9 6 1 3 0 5 0 5 0 A 0 6 0 1
Accessories
Receptacles: K S - 9 6 1 3 5
Tools
Material
Plating
versions
Tip style
∅ ∅ (inch)
ø 0,8 (.031)
1,3 (.051)
2,6 (.102)
GKS-761 ... M 5,3
(.209)
(.110)
2,8
ø2 ø 2,05 ø 2,3
(.079) (.081) (.091)
(.047) ø1,2
2 0,2
(.079) (.008)
6 (.236)
KS-761 60 35 M-R
GKS-761 ... M in
KS-761 60 35 M-R
Operating temperature
Standard: -40° up to +80° C
Test probe: G K S 7 6 1 3 0 5 0 8 0 A 1 0 0 1 M
Receptacle: K S – 7 6 1 6 0 3 5 M - R
Information
Grid:
Product
≥ 3,00 mm
≥ 120 Mil Short-stroke and Charging Test Probes
Installation height with KS: 2,8 / 3,1 / 4,3 mm (.110/.122/.169)
Recommended stroke: 1,0 mm (.039)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
ø 2,5 [.098] ø 2,5 [.098] ø 2,5 [.098] ø 1,3 [.051]
E-TYPE
DKS
3 02 ∅ 1,30 A
ø 2 [.079] ø 1,3 [.051] ø 2 [.079] ø 1,3 [.051] ø 2 [.079]
(.051)
3 03 ∅ 1,30 A
(.051)
Flying Probe
Bead Probe
2,1 [.083] 2,1 [.083] 3,7 [.146] 3 04 ∅ 1,30 A
(.051)
2,6 [.102] 2,6 [.102] 4,2 [.165]
5,1 [.201] 5,3 [.209] 6,7 [.263]
3 05 ∅ 1,30 A
GKS-967 GKS-967 ... G GKS-967 215 (.051)
Fine Pitch
ø 2,3 ø 2,5 ø 2,3 ø 2,5 ø 0,63 ø 2,3 3 06 ∅ 1,30 A
[.091] [.098] [.091] [.098] [.025] [.091] (.051)
2 15* ∅ 1,30 A
(.051)
Stand. GKS
* Installation height: 4,2 mm (.165)
Metric
0,2 [.008] 0,2 [.008] 2 [.079]
2,5 [.098] 5 [.197] 7 [.276]
KS-967 70
(.102)
2,6
KS-967 25 KS-967 50
M 2,5 x 0,25 GKS-967 without KS
short / long
ø 2,95 [.116]
[.098 x .010] SW 3 [.118]
HSS
ø 2 [.079] ø 2,75 [.108] ø 3,5 [.138] ø 1,3 [.051]
(.122)
Robust HSS
3,1
Dipole HSS
2,3 [.091] 0,2 [.008] 2,1 [.083]
SKS
KS-967 60 35 M-R
Step Probes
GKS ... M
Mechanical data Mounting hole size GKS 967
Working stroke: 1,0 mm (.039) in CEM1 and FR4 Recommended screw-in torque:
Maximum stroke: 1,2 mm (.047) with receptacle: 2,28 - 2,29 mm
∅
Min.: 3 cNm / Max.: 5 cNm
Spring force at work. stroke: 2,0 N (7.2oz) (.0898 - .0902)
rotating GKS
VF / Non-
Alternative: 1,0 N (3.6oz) without receptacle: ∅ 2,00 mm (.0787)
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Type “C”,
Assorted
1 = Brass “MC”
3 = BeCu
Test probe: G K S 9 6 7 3 0 4 1 3 0 A 2 0 0 1
Accessories
Receptacles: K S – 9 6 7 2 5 K S – 9 6 7 5 0 K S – 9 6 7 7 0
Tools
Material
Plating
versions
2 2,5 1,3 Tip style
0,079 0,098 0,051 ∅ ∅ (inch)
2 2,5 1,3
2 2,5
0,079 0,098 1,3 0,051
0,079 0,098 0,051 3 05 ∅ 1,30 A
(.051)
0,106
0,083
2,7
0,0830,106
2,7
0,106
8,2 2,7
2,7
0,106
0,106
2,7
0,3230,106
8,2
8,2 0,323
0,323
2 2,5 1,3
0,079 0,098 0,051
2 2,5 1,3
2 2,5 0,079 0,098 1,3 0,051
0,079 0,098 0,051
GKS-970 ... K
4,6 without KS
GKS-970
0,181
4,6
4,6 5,2 0,181
0,1810,205
5,2
10,7 5,2
0,205
0,421
0,205
10,7
10,7
2,3 0,421
2,5 2,3 2,5
0,421
0,091 0,098 0,091 0,098
2,3 2,5 2,3 2,5
2,3 0,0912,5 0,098 2,3 2,5
0,091 0,098
0,091 0,098 0,091 0,098
0,2 0,2
KS-967 25 KS-967 50 0,008
0,008
0,2 0,2
2,50,2 5 0,2 0,008
0,008
0,098
0,008 0,197 0,008
2,5 5
2,5 0,098 5 0,197
0,098 0,197
Operating temperature
Standard: -40° up to +80° C
*with special designation “C”:
-100° up to +200° C (1,0 N; 2,0 N)
Test probe: G K S 9 7 0 3 0 5 1 3 0 A 2 0 0 1
Receptacles: K S – 9 6 7 2 5 K S – 9 6 7 5 0
Information
Grid:
Product
≥ 6,50 mm
≥ 260 Mil Test Probe with Continuous Plunger
Installation height with KS: 7,0 mm (.276)
Recommended stroke: 4,0 mm (.157)
Standard
GKS
Mounting and functional dimensions Available tip styles
Material
Further versions
Plating
Tip style
∅ ∅ (inch)
E-TYPE
DKS
2 01* ∅ 4,00 N
ø 2,45 [.096]
Solder ContinuousPlunger ø 3,5 [.138] ø 1,8 [.071]
(.157)
Connection øø1,3
1,4 [.055] ø5 ø 3 [.118] ø6 ø s.tbl.
ø 1,7Solder
[.067] ø 3ContinuousPlunger
[.118]
ø 2,45 ø 3
ø4
(.051) (.197) (.236) (.157)
Connection ø1,3 ø5 ø6 ø4 2 04
∅ 4,00
N
(.096) (.118)
ø 2,45 ø 3 (.197) (.236) (.157)
Flying Probe
(.051) (.157)
Bead Probe
SE-503
(.096) (.118) GKS-503
2 05 N
∅ 4,00
7(.276)
7 [.276] 8
8 [.315] 2[.079] (.197) 7 [.276] 4 [.157] (.157)
(.315) 1 5
(.039)
7(.276) 108 (.394) 29 (1.142)
10 [.394] 38 [1.496]
(.315) GKS-364 (.039) 1 5 (.197) 2 06 N
10 (.394) SE-503 29 (1.142) ∅ 4,00
(.157)
Fine Pitch
ø5,6GKS-364 ø6 ø5,6
SE-503
(.220)
ø5,6 ø6
ø 3,5 [.138] ø 3,9 [.154]
ø6
(.220) (.236) (.236) * Angle of tip 60°
ø5,6 ø6 (.220) (.236)
(.220) (.236)
KS-103 23
Stand. GKS
0,25 [.010
1 (.039)
Metric
1 22 (.866) 1
(.039) 1 (.039)
22 [.866](.866)
22 (.866) 22 (.866) 23
RKS-364 22 (.039)
RKS-364 23 (not-plated) ø6 ø5,6
KS-364 23 (plated) ø6
RKS-364 23
(.236) (.220) (.236)
ø6 ø5,6 ø6 [.120]
ø 3,05 ø 3,9 [.154]
short / long
(.236) (.220) (.236)
5,7
HSS
(.224)
5,7
(.224)
3 1 1 (.039)
(.118) (.039) 12,5 (.492)
3 1 2 [.079] 1 3(.039)
[.118] 5 [.197]
DS-364 03 DS-364
12,5 01
Robust HSS
(.492)
Dipole HSS
(.118) (.039) KS -364 125
DS-364 03 DS-364 DS-103
01 02 DS-103 05*
KS -364 125 DS-103 03*
SKS
Mechanical data Materials
Working stroke: 4,0 mm (.157) Plunger: Steel, nickel-plated
Maximum stroke: 5,0 mm (.197) Barrel: Brass, gold-plated
Step Probes
GKS ... M
Spring force at work. stroke: 1,5 N (5.4oz) Spring: Steel, gold-plated
Alternative: 0,6 N (2.2oz); 3,0 N (10.8oz), or stainless steel**
8,0 N (28.9oz) Receptacles:
RKS-364 23: Brass, not plated
KS-364 125/KS-364 23: Brass, gold-plated
rotating GKS
VF / Non-
Electrical data Mounting hole size
Current rating, conn. to plunger: 15-20 A with receptacle: 5,59 - 5,60 mm
∅
Current rating, connection to KS: 5 - 8 A (.2201 - .2205)
Ri typical, connection to plunger: < 10 mW without receptacle: ∅ 5,00 mm (.1969)
Ri typical, connection to KS: < 30 mW RF Test Probes
(** < 100 mW)
Dipole-GKS
Operating temperature
Standard: -40° up to +80° C
**with 1,5 and 3,0 N-spring:
-100° up to +200° C
PKS
PSK
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height
material (1/100 mm) N = Nickel (dN) (mm)
2 = Steel
Assorted
GKS
Test probe: G K S 3 6 4 2 0 4 4 0 0 N 1 5 0 1
Receptacles: R K S – 3 6 4 2 3 K S – 3 6 4 2 3 K S – 3 6 4 12 5
Accessories
Lamellar plug: S E – 5 0 3
(for plugging onto the end of the plunger)
Tools
Material
Further versions
Plating
ø4,97 ø6 ø4
ø6 ø4
Tip style
∅ ∅ (inch)
(.196) (.236) (.157)
GKS-365
2 04 ∅ 4,00 N
GKS-365 (.157)
(.039) 1 5 (.197)
15 (.591)
(.039) 1 5ø5,6 (.197) 1 05 A
ø6 ø5,6 ø6 ø6 ∅ 4,00
(.236) (.220) (.236)
(.220) (.236) 15 (.591) (.157)
ø5,6 ø6
ø6 ø5,6 ø6 ø5,6 ø5,6 ø6 ø6
5,7 (.236) (.220) (.236) (.220) (.220) (.236)(.236) (.220) (.236)
(.224) 2 06 A
∅ 4,00
Ø 5,7 3 1 1 (.039) 1 (.039) (.157)
(.224) (.118) (.039) 12,5 (.492) 22 (.866)
1 1 13
DS-364 03 3 DS-364 1
01 KS-365 125 1 (.039)
RKS-365 23
1 (.039)
22 (.866) (.039) 1 * ∅ 4,00
N
22 (.866) (.039)
(.118) (.039) 12,5 (.492) 22 (.866)
(.157)
DS-364 03 DS-364 01 KS-365 125 RKS-365
RKS 23 (not-plated)
-365 23 KS-365 23 (plated)
13S
1 ** ∅ 4,00
A
(.157)
ø5 ø6
GKS 366
ø3,95
(.197) (.236) (.156)
ø5 ø6 ø3,95
(.197) (.236) (.156)
Available tip styles GKS 366
GKS-366
Material
GKS-366 Further versions
Plating
Tip style
∅ ∅ (inch)
(.039) 1 (.039) 1
10 (.394) 10 (.394)
31 (1.220) 31 (1.220)
ø5,6 ø6 1 05 ∅ 4,00 N
ø6 ø5,6 ø6 ø5,6 ø5,6 ø5,6 ø6 ø6ø5,6
ø6 ø6 (.220) (.236)
ø6 (.220) (.236)
(.236) (.220) (.236)
(.236) (.220) (.236) (.220)
(.236) (.220) (.236) (.157)
5,7
(.224)
Ø 5,7
3 05 A
(.224)
3 1 1 (.039) 1 (.039) ∅ 4,00
12,5 (.492) 22 (.866) 1 1 (.157)
(.118) (.039)
1 22(.039) 1 (.039)
3 1 (.866) (.039) 22 (.866) (.039)
(.118) DS-364
DS-364 03 (.039)
01 KS-364 125 12,5 (.492) RKS-364 23 22 (.866)
56
KS-366 23 (plated) 3 * A
DS-364
DS-36403
03 DS-364 01
DS-364 01 KS-364 125 RKS-366 23 (not-plated)
RKS-364 23 ∅ 4,00
(.157)
Ordering example Series Tip Tip style Tip diameter Plating Spring force Collar height Special
material (1/100 mm) A = Gold (dN) (mm) designation
1 = Brass N = Nickel “S“
2 = Steel
3 = CuBe
Test probe: G K S 3 6 5 1 0 5 4 0 0 A 1 5 0 1
Test probe: G K S 3 6 6 1 0 5 4 0 0 N 1 5 0 1
Information
Grid:
Product
≥ 1,91 mm
≥ 75 Mil Solderable Test Probes
Installation height without KS: 17,4 mm (.685)
Recommended stroke: 3,2 mm (.126)
Standard
GKS 941
GKS
Available tip styles
Material
Further versions
Plating
ø0,5 (.020) ø1,5 (.059) ø0,5 (.020) Tip style
∅ ∅ (inch)
GKS-941 Type 1
E-TYPE
DKS
2,5 5,2 (.204) 3 01 ∅ 0,50 R
(.020)
(.098) 20 (.787)
ø1,0 (.039) 3 05 ∅ 0,50 A
(.020)
GKS-941 Type L
Flying Probe
Bead Probe
2,5
(.098)
Grid:
GKS 064 ≥ 2,54 mm
Fine Pitch
≥ 100 Mil
Installation height without KS: 12,3 mm (.484)
Recommended stroke: 1,4 mm (.055)
ø1,0 (.039) Ø1,37 (.054) (.076) Ø1,93
Available tip styles
Stand. GKS
Metric
GKS-064 Type L
Material
Further versions
Plating
2,5 (.106) Tip style
2,7
∅ ∅ (inch)
(.098)
14,8 (.583)
3 05 ∅ 1,93 A
short / long
(.076)
HSS
Grid:
GKS 986 ≥ 2,54 mm
≥ 100 Mil
Installation height without KS: 19,0 mm (.748)
Robust HSS
Dipole HSS
Recommended stroke: 3,0 mm (.118)
(.079) Ø2 Ø2,3 (.091) Ø2 (.079) Ø1,3
(.051) Available tip styles
Material
Further versions
Plating
GKS-986 Tip style
∅ ∅ (inch)
SKS
2,5 (.098) 5 (.197)
21,5 (.846) 1 05 ∅ 1,30 A
(.051)
Step Probes
GKS ... M
Mechanical data GKS 941 GKS 064 GKS 986
Working stroke: 3,2 mm (.126) 1,4 mm (.055) 3,0 mm (.118) Other solderable test probes:
Maximum stroke: 4,0 mm (.157) 1,7 mm (.067) 5,0 mm (.197) see GKS-913, others also available.
Spring force at work. stroke: 0,8 N (2.9oz)* 0,4 N (1.4oz) 1,0 N (3.6oz)*
Alternative: 1,7 N (6.1oz); 0,2 N (0.7oz);
rotating GKS
Warning:
VF / Non-
3,5 N (12.6oz) 0,6 N (2.2oz) Probes should be soldered with great
care. Ensure the inside of the barrel
Electrical data GKS 941 GKS 064 GKS 986 is not exposed to high temperatures,
Current rating: 5 - 8 A 5 - 8 A 5-8A because this could destroy the spring.
Ri typical: <100 mW <100 mW <100 mW
RF Test Probes
Dipole-GKS
3 = BeCu
GKS
Test probe: G K S 9 8 6 1 0 5 1 3 0 A 1 0 0 1
Tools
Accessories
Test Probe/Test Fixture
In addition to the classic range of test probes for the testing Stroke measurement probes are used to determine the
of PC boards and components, further test probes are avail- working stroke of a test probe when contacting a DUT. This
able as test accessories: can be helpful when selecting the optimal test probe, or
solving contact issues which may arise.
Interface GKS and contact terminals are used in interface PCB support pins provide a spring-loaded base when inser-
blocks to reliably transfer signals in internal, external, and ting the PCB in the test fixture or inline test device, especially
customised interfaces. in test set-ups without a PCB support plate.
Working
stroke
Design of signal transfer positions Testing of test probe or DUT working stroke Probes to support PCB in test fixture
186
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Accessories
Fine Pitch
and customised interfaces. GKS-945 190
In order to realise the optimal transfer, several varied GKS GKS-946 190
and contact terminals with a variety of tip styles, installation GKS-938 190
heights, and connection options are available. GKS-100 357 150 ... 190
Stand. GKS
Scale 1:1 (mm) GKS-100 307 150 ... 190
Metric
GKS-100 306 229 ... 190
Stroke measurement probes are used to define the working
Contact Terminals 191
stroke of a test probe when contacting a DUT. This can be
100 helpful when selecting the optimal test probe, or solving
short / long
contact issues which may arise. Stroke Measurement Probes
HSS
90 In order to determine the stroke, the stroke measurement
probes (HMS) are inserted in a receptacle mounted in the HMS-075 192
test fixture. When the fixture is closed (with the DUT in HMS-100 192
80 place) the HMS is activated and remains in the new position. HMS-422 192
Robust HSS
Dipole HSS
Then the performed stroke can be determined (by measu-
PCB Support Pins
70 ring the difference between the starting position and the end
position). The HMS plunger can be returned to the home
GKS-416 193
60 position manually after the measurement is complete.
GKS-504 193
SKS
GKS-102 193
PCB support pins provide a spring-loaded base when inser- GKS-414 193
50
ting the PCB in the test fixture or inline test device, especially
in test set-ups without a PCB support plate.
Step Probes
40
GKS ... M
30
rotating GKS
VF / Non-
20
10
100
5
RF Test Probes
Dipole-GKS
0
90
HMS-100
HMS-422
GKS-945
GKS-100
GKS-416
GKS-102
KT-158
KT-279
-10
80
-20
PKS
PSK
70
-30
60
Assorted
GKS
-40
50 Shown without KS - other installation heights available
-50
40
Accessories
-60 Note:
30 See next page for overview
and comparison table.
-70
20
Tools
187
-80 187
10
Technical Information
Accessories
Overview and Comparison
Installation
Grid Working Max. Spring forces Shortest
Test probe Current height with
Series size stroke stroke (N)
verison rating (A) receptacle (mm) probe Page
(≥ mm) (mm) (mm) (mm)
min. max. min. max.
GKS-945 2.54 2.1 3.2 5 1.1 1.3 3.7 4.3 21.7 190
GKS-946 2.54 3.2 3.9 5 1.2 - 4.4 - 22.4 190
Interface GKS-938 2.54 3.6 4.3 5 1.5 - 6.8 - 24.8 190
test probes
GKS-100 357 150 … 2.54 3 4 5 1.2 - 13.6 - 31 190
and contact
terminals GKS-100 307 150 … 2.54 4.3 6.35 5 1 3 16 - 33.4 190
GKS-100 306 229 … 5.08 4.3 6.35 5 1 3 16 - 33.4 190
Contact terminals - - - - - - - - - 191
HMS-075 1.91 4.3 6.35 - - - 7.7 - 25.4 192
Stroke
measurement HMS-100 2.54 4.3 6.35 - - - 8.4 - 25 192
probes HMS-422 2.54 6.4 8 - - - 16 - 38.4 192
GKS-416 4 9.2 11.5 - 5 - 18.2 20 55 193
188
189
Test Probes for Interfaces
from INGUN, GenRad, Pylon, R & S, Teststation, Teradyne
and Keysight (Agilent/HP 3070)
Material
Further versions
Plating
(.054) (.042)
GKS-945 301 106 A 1300 Tip style
∅ ∅ (inch)
21,7 (.854) 3,2 (.126)
GKS-945 357 106 A 1100 ∅ 1,06 A
3 01
3,8 (.150) (.042)
22,3 (.878)
24,8 (.976)
(.169) 4,3 2 (.079) GKS-938
Material
Further versions
Plating
ø 1,37 ø 0,9 Tip style
(.054) (.035) ∅ ∅ (inch)
GKS -100 357 150 ...
(.157) 4 2 (.079)
31 (1.220)
3 07 ∅ 1,80 A
(.071)
GKS -100 307 150 ...
for Teradyne 800 / 1800 (.252) 6,4 2 (.079)
33,4 (1.315)
GKS-100
GKS -100 306 229 ...
6,9 1,5 (.059)
Material
for HP 3070 (.272) Further versions
Plating
33,4 (1.315) Tip style
∅ ∅ (inch)
Receptacles ø 1,67 ø 1,8
(.066) (.071)
3 57 ∅ 1,50 A
KS-945 47 for (.059)
0,2
GKS-945
(.008)
GKS-946 37,6 (1.480)
GKS-938 GKS-100
0,64 Ø 1,67 ø 1,85 (.073) for Teradyne 800/1800 Interface
(.066)
(.025)
Material
Further versions
Plating
KS-100 47 G for Tip style
GKS-100 7,6 (.300) ∅ ∅ (inch)
10 (.394) 25 (.984)
40 (1.575)
3 07 ∅ 1,50 A
(.059)
Mechanical data
Type Working Max. Spring force at Installation height
stroke stroke working stroke with KS GKS-100
mm (inches) mm (inches) N (oz) mm (inches) for Agilent/HP 3070 Interface
Material
Further versions
Plating
945 301 2,1 (.083) 3,2 (.126) 1,3 N (4.7oz) 3,7 (.146) * Tip style
∅ ∅ (inch)
945 357 2,6 (.102) 3,2 (.126) 1,1 N (4.0oz) 4,3 (.169) *
946 301 3,2 (.126) 3,9 (.154) 1,2 N (4.3oz) 4,4 (.173) *
ø3,1
3 06 A
938 307 3,6 (.142) 4,3 (.169) 1,5 N (5.4oz) 6,8 (.268) *
∅ 2,29
100 357 3,0 (.118) 4,0 (157) 1,2 (Ord.-No.=10) 13,6 (.535) / variable ** (.090)
100 ... 4,3 (.169) 6,35 (.250) 1,0/2,0/2,25/3,0 16,0 (.630) / variable **
*with KS-945 47 ** with KS-100 47 G *** Services:
Mounting hole size *** Materials Customised contact blocks drilled
for KS-945 47: Plunger: BeCu , gold-plated according to customer demands (and
- in CEM1 using collar ∅ 1,68 - 1,69 mm Barrel: Nickel-silver or Bronze, gold-plated which match certain INGUN receptac-
(.0661 - .0665) Spring: Steel, gold-plated les) are available from INGUN.
for KS-100 47 G:
- press-ring inserted Collar height and installation height Note:
in CEM1:∅ 1,71 - 1,73 mm (.0673 - .0681) The installation height is variable, depen- To order test probes with bent bar-
in FR4: ∅ 1,70 - 1,72 mm (.0669 - .0677) ding on position of the press-ring. rel end, use special designation “B”
(banana-shaped).
Electrical data Operating temperature Contacting terminals for various inter-
Current rating: 4-5A Standard: -40° up to +80 °C faces available upon request.
Ri typical: 20 mW
Test probe: G K S 9 4 5 3 0 1 1 0 6 A 1 3 0 0
Information
Product
Grid: for Interfaces and Transfer Fields
≥ 2,54 mm
≥ 100 Mil
Standard
GKS
Contact terminals with collar height: Contact terminals with collar height: Other contact terminals:
3 mm (.118) 2 mm (.079)
E-TYPE
DKS
KT-254 W-E03 (wire-wrap) KT-254 W-E02 (wire-wrap) KT-254 W3 E12 (wire-wrap)
22 (.866)
For assembly in INGUN ZSK Transfer Field
23 (.906)
14 (.551)
(ZSK = Top-side Contacting Unit)
15 (.591)
3 2 (.079) 32 (1.260)
(.118) 24 (.945) 45
Flying Probe
º
Bead Probe
12 (.472)
3 (.118)
0,6 ø1,9 8 ø2,03 ø2,15 0,6 ø1,9 8 ø2,03 ø2,15
(.025) (.078) (.080) (.085) (.025) (.078) (.080) (.085)
KT-254 W3 E03 (wire-wrap) KT-254 W3 E02 (wire-wrap) 0,6 ø1,98 ø2,0 3 ø2,15 ø1
22 (.866) (.024) (.078) (.080) (.085) (.039)
23 (.906)
Fine Pitch
15 (.591) 45 14 (.551) 45 KT-158 02 (Order No. 9408)
º (.118) º
3 3
(.118) 2 (.079)
Contacting Terminal for GenRad Interface
12,9 4,1 0,8
(.508) (.161) (.031)
Stand. GKS
(.025) (.078) (.080) (.085) (.039) (.025) (.078) (.080) (.085) (.039)
(.024) (.053) (.060) (.071)
Metric
KT-254 L-E03 (Solder) KT-254 L-E02 (Solder)
KT-158 (Order No. 3650)
18 (.709) 17 (.669)
4 13 (.512) Contacting Terminal for Zehntel Interface
4 12 (.472)
(.157) 3 13 4 0, 8
(.157) 2 (.079)
(.118) (.512) (.157) (.031)
short / long
HSS
ø1,1 (.043)
ø0,8 ø1,9 8 ø2,03 ø2,15 ø0,8 ø1,98 ø2,03 ø2,15 0,6 ø1,35 ø1,52 ø1,8
(.031) (.078) (.080) (.085) (.031) (.078) (.080) (.085) (.024) (.053) (.060) (.071)
Robust HSS
Dipole HSS
18 (.709) 17 (.669)
4 13 (.512) 45º 4 12 (.472) 45
(.157) (.157)
º ø0,6 (.042)
(.024)
3 (.118) 3 0,6 ø1,35 ø1,52 ø1,8
(.118) 2 (.079)
(.024) (.053) (.060) (.071)
SKS
(.031) (.085) (.039)
(.118) 3 (.157) 4 3 (.118)
KT-120 L3 E02 - 30 (Solder) KT-254 L3 E02 - 30 (Solder Connection)
High-current Contact Terminal
17 (.669)
20 (.787) 45º
4,6 12 (.472) 45
7.5 2.5 º ø1,5 ø2,45 ø2,6 ø4
Step Probes
(.181) (.118) 3
GKS ... M
(.295) (.098) (.059) (.096) (.102) (.157)
2 (.079)
3 1 (.039)
(.118)
ø2,9 5 ø2,98 ø3,05 ø3,5 ø1
ø1,4 ø1,9 8 ø2,0 3 ø2,15 ø1
KT-279 102 300
(.116) (.117) (.120) (.138) (.039)
(.055) (.078) (.080) (.085) (.039) (to solder in)
ø1 ø3
rotating GKS
KT-150 L3 E03 - M3
VF / Non-
(.039) (.118)
High-current Contact Terminal KT-254 W-PL (wire-wrap)
22 (.866) 45º 22 (.866) KT-112 143 215 E02 (replaceable,
8
3 14 (.551) will be used with KS-112)
(.118)
(.315) (.079) 2 19 (.748) 45
º
(.118) 3
RF Test Probes
Dipole-GKS
2 (.079)
Mounting hole size * Collar height and install. height for KT-254
for KT-254: The installation height of the contact ter- * Services:
PKS
PSK
in CEM1 und FR4 ∅ 1,98 - 1,99 mm minals is determined by the collar height.
Customised contact blocks drilled ac-
(.0780-.0783) cording to customer demands (which
for KT-158: match certain INGUN receptacles) are
in CEM1 and FR4 ∅ 1,38 - 1,40 mm Electrical data available from INGUN.
(.0543 - .0551) Ri typical: < 5 mW
Assorted
GKS
for KT-586:
in CEM1 and FR4 ∅ 2,55 - 2,57 mm
(.1004-.1012) Materials
for KT-120: Contact terminals: Brass , gold-plated
in CEM1 and FR4 ∅ 3,00 - 3,02 mm KT-586: Brass, rhodium-plated
Accessories
(.1181 - .1189)
for KT-150:
in CEM1 and FR4 ∅ 4,00 - 4,02 mm
(.1575 - .1583)
Tools
H M S 1 0 0 3 0 2 1 5 0 A
H M S 4 2 2 3 0 6 2 0 0 A
Information
Product
for Fixture Customising
Standard
GKS
PCB support probe GKS-416 Mechanical data
Working stroke: 9,2 mm (.362)
Maximum stroke: 11,5 mm (.453)
Spring force at work.stroke: 5,0 N (18.1oz)
ø 2,65 (.104) ø 3 (.118) Ø 1,6 (.063) ø 3 (.118)
E-TYPE
DKS
Materials
Plunger: BeCu , gold-plated
2 or 4 (.079 or .157) 4, 5 (.177) Barrel: Brass, gold-plated
Spring: Steel, gold-plated
Flying Probe
18 or 20 (.709 or .787)
Bead Probe
55 (2.165) Tip: Delrin
Receptacle: KS-113 23
Fine Pitch
GKS for install. height 18,0 mm (.709): G K S 4 1 6 0 0 2 3 0 0 A 5 0 0 2
Stand. GKS
PCB support probe GKS-102 Mechanical data
Metric
Working stroke: 4,8 mm (.189)
Maximum stroke: 6,5 mm (.256)
0,64 ø2 ø 2,3 ø1 Ø 4 Spring force at work. stroke: 1,5 N (5.4oz)
(.025) (.079) (.091) (.039) (.157) Alternative: 3,0 N (10.8oz); 5,0 N (18.1oz)
short / long
Materials
HSS
8
Plunger: Steel , gold-plated
2 (.079) 7,5 4 (.157) Barrel: Brass, gold-plated
(.315)
43,5 (1.713) (.295) Spring: Steel, gold-plated
Tip: PVC
Receptacle: KS-102 23
Robust HSS
Dipole HSS
Mounting hole size
Ordering example see GKS-102 (page 66)
GKS for install. height 13,5 mm (.531): G K S 1 0 2 2 5 0 4 0 0 P 3 0 0 2 W
SKS
Test probe GKS-504 Mechanical data
With continuous plunger, for the activation Working stroke: 11,2 mm (.441)
of micro switches Maximum stroke: 14 mm (.551)
Spring force at work. stroke: 0,5 N (1.8oz)
Step Probes
Alternative: 3,0 N (10.8oz); 5,0 N (18.1oz)
GKS ... M
ø 1,4 (.055) ø 2,65 (.104) ø 3 (.118) ø 1,8 (.071)
Materials
Plunger: BeCu , nickel-plated
Barrel: Steel, gold-plated or stainless steel
rotating GKS
VF / Non-
7 4 or 10 (.157 or .394) Spring: Brass, gold-plated
(.276) 18 or 24 (.709 or .945) Receptacle: KS-113 23
56 (2.205)
Mounting hole size
see GKS-113 (page 68)
RF Test Probes
Dipole-GKS
Ordering example
GKS for install. height 18,0 mm (.709): G K S 5 0 4 3 0 5 1 8 0 N 0 5 0 4
Ordering example
GKS for install. height 15,8 mm (.622): G K S 4 1 4 2 0 2 5 0 0 A 1 5 0 2
Tools
Tools
To press in receptacles and spring-loaded test probes
(GKS)
INGUN tools make an important Receptacles are pressed into the probe plate, either up to the
contribution to secure, precise collar stop or by pressing the press-ring to allow for variable
testing. Only with optimally installed adjustment of the installation height. Depending on their de-
receptacles and test probes, can reliable sign, spring-loaded test probes are pressed into or screwed
testing be guaranteed. Depending on the into the receptacle using a suitable tool. There are optimally
receptacle and test probe to be installed, matched bit inserts, according to tip style and diameter of
various tools and bits are available. the probe.
KS with fixed depth (stop) KS with variable depths Remove KS Install GKS in KS Install and remove GKS in KS (head-
(press-ring) Ø > plunger shaft-Ø)
194
Information
Product
Contents
Technical Information
Standard
GKS
E-TYPE
DKS
Flying Probe
Bead Probe
Tools
KS installation and
removal
Fine Pitch
SW-KS-xxx 196
SW-GKS 196
SW-KS-xxx-G 196
AW-KS-Set-ICT / CABLE 196
Stand. GKS
Metric
GKS installation and
removal
short / long
SW-GKS-xxx 196
HSS
SW-GKS 196
SW-ZW-GKS-xxx 196
Robust HSS
Dipole HSS
GKS screw-in and
unscrew
SKS
BIT-GKS-xxx M-B 197 - 198
BIT-T-xxx M 197 - 198
Step Probes
GKS ... M
rotating GKS
VF / Non-
RF Test Probes
Dipole-GKS
Torque screwdriver Bit insert for barrel with spanner flat Bit insert for interlocking
connection
DW-x-S BIT-GKS M
BIT-T-xxx M
PKS
PSK
drivers are available in 1, BIT-GKS- xxx M-B are for GKS with head-Ø ≤ spanner flat an interlocking
3.5 and 20 cNm versions. width on probe. Especially for installing GKS with limited connection.
pitch distance (small grid).
Adjustable Torque screw
Accessories
195
195
Insertion and
Extraction Tools
Insertion and
Insertion Tool for
Series ExtractionTool for Insertion Tool for KS
GKS
GKS, Tip-Ø > Shaft-Ø
SW-KS-xxx G [4]: Variably
GKS-001 SW-GKS adjustable insertion tool,
GKS-002 SW-GKS SW-ZW-GKS-100 SW-KS 100 / SW-KS-100 G [4] SW-GKS: Universal for receptacle with press-
GKS-003 SW-GKS SW-KS-102 insertion tool for GKS ring (* can be purchased
GKS-004 SW-GKS individually)
GKS-005 SW-GKS
GKS-015 SW-GKS-081 [1] SW-KS-050 G [4]
GKS-035 SW-ZW-GKS-075 SW-KS-101 / SW-KS-075 G [4]
GKS-040 SW-KS-040 / SW-KS-040 G [4]
XXX-050 SW-GKS-081 [1] SW-KS-050 G [4]
GKS-069 SW-GKS-187 B SW-KS-080 G-SW-KS-xxx G
SW - H (Handle)
XXX-075 SW-ZW-GKS-075 SW-KS-101 / SW-KS-075 G [4] (Handle)
GKS-080 SW-ZW-GKS-080 SW-KS-080
GKS-081 SW-GKS-081 [1] SW-KS-080
GKS-098 SW-GKS SW-KS-103
XXX-100 SW-GKS-100 B [1] SW-ZW-GKS-100 SW-KS 100 / SW-KS-100 G [4]
GKS-101 SW-ZW-GKS-101 SW-KS-101 H-SW-KS-xxx *
(Tube)
GKS-102 SW-ZW-GKS-112 SW-KS-102
E - SW GKS
GKS-103 SW-ZW-GKS-103 SW-KS-103
(Bit)
GKS-112 SW-ZW-GKS-112 SW-KS-112 D-SW-KS-xxx N *
GKS-113 SW-ZW-GKS-103 SW-KS-113 (Bit)
GKS-135 SW-GKS-100 B [1] SW-ZW-GKS-100 SW-KS 100 / SW-KS-100 G [4]
GKS-181 SW-GKS-181 [1] ZW-GKS-912 SW-KS-181 Fig.1
Fig.2
GKS-204 SW-GKS-912 A [2] / 912 B [3] ZW-GKS-912 SW-KS-112 AW-KS-Set-ICT / AW-KS-Set-CABLE:
GKS-412 SW-ZW-GKS-112 SW-KS-112 Extraction tool for KS
XXX-422 SW-GKS-912 A [2] / 912 B [3] ZW-GKS-912 SW-KS-112
GKS-502 SW-ZW-GKS-112 SW-KS-102
GKS-503 SW-ZW-GKS-103 SW-KS-103
GKS-550 SW-GKS-181 [1] SW-KS-050 G [4]
GKS-710 ZW-GKS-912 SW-KS-112
GKS-713 SW-GKS SW-KS-113
GKS-714 SW-GKS SW-KS-113
GKS-725 SW-ZW-GKS-100 SW-KS-100
GKS-912 SW-GKS-912 A [2] / 912 B [3] ZW-GKS-912 SW-KS-112
GKS-913 SW-ZW-GKS-103 SW-KS-113
GKS-961 SW-GKS-961
GKS-967 SW-GKS SW-KS-102
HSS-118 SW-ZW-GKS-112 SW-KS-112
HSS-120 SW-ZW-GKS-103 SW-KS-113
HSS-150 SW-GKS
PKS-200/220 SW-GKS SW-KS-102
PKS-300/299 SW-GKS SW-KS-103
SKS-075 SW-ZW-GKS-075 SW-KS-075 G [4] E-AW-KS-xxx
Insert
SKS-100 SW-ZW-GKS-100 SW-KS-100 G [4]
SKS-215 SW-ZW-GKS-112 SW-KS-112 The set for extraction of receptacles contains the bits
SKS-415/425 SW-ZW-GKS-103 SW-KS-113 E-AW-KS-xxx for the series, e.g. E-AW-KS-040 for KS-040.
SKS-419/429 SW-SKS-419-429-300
SKS-419/429 SW-SKS-419-429-500 AW-KS-Set-ICT AW-KS-Set-CABLE
[1]
Insertion tool for plunger with continuous shaft [2]
universal use E-AW-KS-040 E-AW-KS-075
[3]
for tip style “09“ [4]
free adjustable [5]
extraction tool
E-AW-KS-xxx
E-AW-KS-050 E-AW-KS-100
Bits
E-AW-KS-075 E-AW-KS-112
E-AW-KS-100 E-AW-KS-113
Ordering example
Insertion and extraction tools for GKS 112: SW–ZW-GKS-112
Information
Product
with BIT tools
47,8 (1.882)
Standard
GKS
øB øA
47,8 (1.882) 48,2 (1.898)
E-TYPE
DW - S (handle without ratchet)
DKS
C
63 (2.480)
48,2 (1.898) 80 (3.150)
Bit tool
Flying Probe
Bead Probe
DW - 1 - S
DW - 3 - S Application example:
BIT-GKS-113 M with test probe GKS 113 M
Fine Pitch
111 (4.370)
DW - 5 - S
Stand. GKS
DW - 20 (pre-set)
Metric
183 (7.205) at DW-20-120 DW - 5 - 40
111 (4.370) DW - 20 - 120
short / long
(freely adjustable) DW-20 with BIT-GKS-113 M
HSS
Plunger Recommend
ØA ØB C Torque key Insertion tools
Series tip-Ø Bit-tool screw-in torque
for receptacles
(Disk-Ø)
Robust HSS
Dipole HSS
(mm) pre-set freely adjustable min. max.
DPS-215 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
DPS-465 M ≤ 2.5 mm BIT-SKS-465 M-B 4 4 - DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
GKS-050 M ≤ 1.1 mm BIT-GKS-050 M-B 1.5 5 30 DW-1-S - - 0.5 cNm 1 cNm SW-KS-080
GKS-075 M ≤ 1.1 mm BIT-GKS-075 M-B 2.3 5 30 DW-1-S - - 0.5 cNm 1 cNm SW-KS-075 G
SKS
GKS-075 M ≤ 1.5 mm BIT-GKS-075 M 2.3 5 30 DW-1-S - - 0.5 cNm 1 cNm SW-KS-075 G
GKS-087 M ≤ 1.1 mm BIT-GKS-050 M-B 1.5 5 30 DW-1-S - - 0.5 cNm 1 cNm SW-KS-050 G
GKS-098 M ≤ 3.1 mm BIT-GKS-503 M-B 4.2 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
GKS-103 M ≤ 3.1 mm BIT-GKS-503 M-B 4.2 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
Step Probes
GKS ... M
GKS-103 M ≤ 4.1 mm BIT-GKS-503 M 5.5 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
GKS-112 MD ≤ 2.0 mm BIT-GKS-112 M-B-FP 2.8 5 30 DW-5-S DW-5-40 3 cNm 5 cNm SW-KS-112
GKS-112 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
GKS-112 M ≤ 3.5 mm BIT-GKS-112 M 4.3 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
GKS-113 M ≤ 3.0 mm BIT-GKS-113 M-B 4.3 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
rotating GKS
VF / Non-
GKS-113 M ≤ 4.2 mm BIT-GKS-113 M 5.3 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
GKS-113 M ≤ 8.0 mm BIT-GKS-113 M-800 10 6 40 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
GKS-204 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
GKS-212 M ≤ 2.0 mm BIT-GKS-212 M 2.7 6 26 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-GKS
RF Test Probes
Dipole-GKS
GKS-313 M ≤ 3.0 mm BIT-GKS-113 M-B 4.8 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
GKS-427 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
GKS-500 M Slot 0.5 BIT-GKS-500 M 3.5 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
GKS-503 M ≤ 3.1 mm BIT-GKS-503 M-B 4.2 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
GKS-503 M ≤ 4.1 mm BIT-GKS-503 M 5.5 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
≤ 2.0 mm
PKS
PSK
GKS-803 M ≤ 4.1 mm BIT-GKS-503 M 5.5 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
GKS
GKS-854 M ≤ 4.0 mm BIT-HSS-150 M 5.5 6 28 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
GKS-899 M ≤ 1.5 mm BIT-GKS-899 M-B 2.4 5 30 DW-3-S - - 2 cNm 3 cNm SW-KS-100
GKS-899 M ≤ 2.0 mm BIT-GKS-899 M 2.8 6 27 DW-3-S - - 2 cNm 3 cNm SW-KS-100
GKS-913 M ≤ 3.0 mm BIT-GKS-913 M-B 4.8 4.8 - DW-5-S DW-5-40 - 5 cNm 10 cNm SW-KS-113
Accessories
Recommend
Plunger tip- ØA ØB C Torque key Insertion tools for
Series Bit-tool screw-in torque
Ø (Disk-Ø) receptacles
(mm) pre-set freely adjustable min. max.
HKR-612 M 3/4 mm BIT-HKR-612 SW8 10 6 - - - DW-20-120 50 cNm -
HKR-612 M 6 mm BIT-HKR-612 SW10 12.5 6 - - - DW-20-120 60 cNm -
HKR-672 M 8/10/12 mm Stecknuss. 14/16/17 - - - - - - 2 Nm -
HKR-694 M 4 mm BIT-HKR-617 400 F - - - - - - - - SW-KS-617
HSS-118 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
HSS-118 M ≤ 3.5 mm BIT-GKS-112 M 4.3 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
HSS-120 M ≤ 3.0 mm BIT-GKS-113 M-B 4.8 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
HSS-120 M ≤ 4.2 mm BIT-GKS-113 M 5.3 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
HSS-150 M ≤ 3.0 mm BIT-HSS-150 M-300 5.5 6 28 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
HSS-150 M ≤ 4.0 mm BIT-HSS-150 M 5.5 6 28 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
HSS-520 M ≤ 3.0 mm BIT-GKS-913 M-B 4.8 4.8 - DW-5-S DW-5-40 - 5 cNm 10 cNm SW-KS-113
HSS-520 M ≤ 3.6 mm BIT-GKS-913 M 5.3 6 27 DW-5-S DW-5-40 - 5 cNm 10 cNm SW-KS-113
HSS-552 M ≤ 4.0 mm BIT-HSS-150 M 5.5 6 28 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
HSS-621 M ≤ 5.0 mm BIT-HSS-621M-500 6.4 6 30 - DW-5-40 DW-20-120 40 cNm -
HSS-623 M ≤ 6.0 mm BIT-HSS-623M-600 7.6 6 30 - DW-5-40 DW-20-120 40 cNm -
HSS-624 M ≤ 6.0 mm BIT-HSS-623M-600 7.6 6 30 - DW-5-40 DW-20-120 40 cNm -
HSS-827 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
KK-541 M - BIT-KK-541 M 5 6 25 DW-5-S DW-5-40 - 5 cNm SW-KS-113
PKS-171 M ≤ 1.6 mm BIT-PKS-171 M-B 2.7 6 26 DW-3-S - - 2 cNm 3 cNm SW-KS-100
PKS-355 M ≤ 2.5 mm BIT-SKS-465 M-B 3.8 4 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
PKS-388 M ≤ 3.7 mm BIT-PKS-388 M-B 4.8 6 30 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-GKS
PSK-350 M ≤ 2.5 mm BIT-SKS-465 M-B 3.8 4 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
SKS-115 M ≤ 3.0 mm BIT-SKS-465 M 4 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
SKS-215 M/MF ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
SKS-215 M/MF ≤ 3.5 mm BIT-GKS-112 M 4.3 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
SKS-435 M ≤ 3.1 mm BIT-GKS-503 M-B 4.2 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
SKS-435 M ≤ 4.1 mm BIT-GKS-503 M 5.5 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-103
SKS-463 MF ≤ 2.5 mm BIT-SKS-465 M-B 3.8 4 - DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
SKS-463 MF ≤ 3.0 mm BIT-SKS-465 M 4 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
SKS-465 MF ≤ 2.5 mm BIT-SKS-465 M-B 3.8 4 - DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
SKS-465 MF ≤ 3.0 mm BIT-SKS-465 M 4 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
SKS-465 MF ≤ 5.0 mm BIT-SKS-465 M-500 6 6 - DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
SKS-465 SF Schlitz 0.8 BIT-SKS-465 S 3 6 28 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-113
T-112 M ≤ 2.0 mm BIT-GKS-112 M-B 2.7 5 30 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
T-112 M ≤ 3.5 mm BIT-GKS-112 M 4.3 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
T-113 M ≤ 3.0 mm BIT-GKS-113 M-B 4.8 4.8 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-113 M ≤ 4.2 mm BIT-GKS-113 M 5.3 6 27 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-113 M ≤ 5.0 mm BIT-T-113 M 6 6 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-785 M ≤ 5.0 mm BIT-T-113 M 6 6 - DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-888 M 3.0 - 4.0 mm BIT-T-888 M-3 3.5 6 23 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-888 M 4.0 - 4.7 mm BIT-T-888 M 5 6 23 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-888 M 5.0 mm BIT-T-912 M 2.6 6 23 DW-20 DW-5-40 DW-20-120 10 cNm 20 cNm SW-KS-113
T-899 M ≤ 1.5 mm BIT-GKS-899 M-B 2.4 5 30 DW-3-S - - 2 cNm 3 cNm SW-KS-100
T-912 M 2.0 - 3.5 mm BIT-T-912 M 2.6 6 23 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-KS-112
VF-3 ≤ 2.1 mm BIT-VF3 M-B 3.3 5 29 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-GKS
VF-3 ≤ 3.0 mm BIT-VF3 M 4 6 27 DW-5-S DW-5-40 - 3 cNm 5 cNm SW-GKS
VF-4 ≤ 2.5 mm BIT-VF4 M-B 4 4 - DW-5-40 - 5 cNm 10 cNm SW-KS-103
VF-4 ≤ 4.0 mm BIT-VF4 M 4 6 27 DW-5-40 - 5 cNm 10 cNm SW-KS-103
VF-5 ≤ 3.0 mm BIT-GKS-113 M-B 5.3 6 27 DW-20 DW-5-40 DW-20-120 5 cNm 20 cNm -
VK-541 M - BIT-KK-541 M 5 6 25 DW-5-S DW-5-40 - 5 cNm -
Note: due to the outer diameter of the insert bit, in some cases the minimum grid size of a probe series cannot be adhered to, or the insert bit in question cannot be used at all.
* Ltotal = 47 mm
Ordering example
Bit-tool for screw-in probe: B I T - G K S - 1 1 2 M-B
Torque keys pre-set: D W - 1 - S D W - 3 - S D W - 5 - S D W - 2 0
Torque keys freely adjustable: D W - 5 - 4 0 D W - 2 0 - 1 2 0
199
M-PR-0036: 03/18 EN-25.3
Headquarters Europe Asia The addresses of our
INGUN Germany Austria China international agencies
Benelux Hong Kong can be found under
Subsidiaries Bosnia-Herzegovina India www.ingun.com
INGUN Benelux Croatia Israel
INGUN China Czech Republic Japan
INGUN India Denmark Korea
INGUN Korea Estonia Malaysia
INGUN Mexico Finland Taiwan
INGUN España France Thailand
INGUN Switzerland Germany Vietnam
INGUN South East Asia Hungary
INGUN Türkiye Italy Africa
INGUN UK Norway South Afirca
INGUN USA Poland Tunisia
Portugal
Romania Australia
Serbia Australia
Slovenia New Zealand
Slovakia
INGUN Prüfmittelbau GmbH
Spain America Max-Stromeyer-Straße 162
Sweden Argentinia
78467 Konstanz
Switzerland Brazil
Germany
Turkey Canada
Phone +49 7531 8105-0
United Kingdom Mexico
Customer Hotline +49 7531 8105-888
USA
Fax +49 7531 8105-65
info@ingun.com
www.ingun.com