Sei sulla pagina 1di 1

NOTES

ROOF: CONCRETE ROOF TILES ON TRUSSES


10mm thick 220mm thick
internal plaster brick wall - TILES ON 38x38mm BATTENS AT 320mm CENTRES MAX
DAMP PROOF MEMBRAINE
10mm thick EMBEDDED AT LEAST 300mm INTO BRICKWORK WITH CONNECTING DEVICES ACCORDING TO
FLOOR FINISH AS ON FLOOR PLAN
skirting to match external plaster TABLE L2, SCHEDULE 1, OF SABS 0400
floor finish -ALL WEB MEMBERS TO BE MINIMUM 38x114mm GRADE 4 WITH EQUAL BAYS SMALLER
30mm SAND CEMENT SCREED D.P.C THAN 1500mm. APPROVED BRACING MUST PREVENT BUCKLING AND KEEP TRUSSES UPRIGHT
85mm SURFACE BED -VALLEY AND HIP RAFTERS TO BE GRADE 6 50x228 SA PINE
25mm SAND BLINDING -LAMINATED TIMBER TO COMPLY WITH SABS 876
-50mm GLASS FIBRE INSULATION TO BE INSTALLED ON CEILING
150mm WELL COMPACTED
CONCRETE ROOF
HARDCORE
-CONCRETE ROOF TO ENGINEER'S DETAIL WITH MINIMUM 50mm THICKNESS
-VERMICULITE SCREED GRADED TO 1:50 FALL TO 100m DIAMETER BILD IN DOWNPIPES

NATURAL GROUND
-WATERPROOFING BY SPECIALIST WITH A TEN YEAR GUARANTEE AS PER SPECIFICATION

FLOORS AND WATERPROOFING


600x230mm CONCRETE STRIP -GROUND FLOOR SLAB=85mm THICK 20mpa CONCRETE PERFECTLY LEVEL AND AT
FOUNDATION FOOTING MINIMUM 150mm ABOVE GROUND LEVEL ON PROPERLY COMPACTED HARDCORE FILL
-25mm THICK SCREED AND FINISHES AS INDICATED
-SUSPENDED CONCRETE FLOOR SLABS TO ENGINEER'S DETAIL AND SPECIFICATIONS
-DPC UNDER ALL WALLS (EXCEPT FREE STANDING), FLOORS AND WINDOW SILLS
AND TO ALL VERTICAL CHANGES IN FLOOR LEVELS
-FLUSHINGS TO ALL PARAPETS AND CHANGES IN ROOF LEVELS

FROM CATCHPIT FITTED WITH GRATING AND SILT TRAP


-PLANTERS TO BE WATERPROOFED AND DRAINAGE INSTALLED

FOUNDATIONS, BRICKWORK & PARTITIONS


110mm INTERNAL BRICK WALL PLASTERED -ALL FOUNDATIONS TO BE 25mpa CONCRETE , AT LEAST 200x700mm. MINIMUM
& PAINTED TO CLIENT'S COLOUR CHOICE 200mm UNDER GROUND TO ENGINEER'S DETAILS AND SPECIFICATIONS
10mm thick -BOUNDARY WALLS' FOUNDATION MUST NOT ENCROACH ON BOUNDARY AND WALLS
internal plaster ARE TO BE PLASTERED AND PAINTED ON THEW INNER WALL
-PARAPET WALLS TO BE ATLEAST 300mmHIGH AND MAXIMUM 500mm WITH BRICKFORCE
IN EVERY COURSE
skirting to match -ALL SCREEN WALLS TO BE AT LEAST 1800mm HIGH ABOVE GROUND LEVEL
-LINTOLS TO BE SUPPORTED MINIMUM 150mm FOR OPENINGS UPTO 4800mm.BRICKFORCE
floor finish
TO BE BUILT IN EVERY COURSE BELOW FLOOR LEVEL AND ABOVE WINDOW LEVEL, EVERY
THIRD COURSE BETWEEN BETWEEN IN CONTINOUS BANDS
-NO TEETHING OR BLOCK BONDING WILL BE ALLOWED UNDER ANY CIRCUMSTANCES
-ANY PARTITION TO BE RODENT PROOF

STAIRS AND BALUSTRADES


-STAIRS TO BE 750mm MIN WIDTH, TREADS 300mm , RISERS 170mm WITH 6mm MAX DEVIATION
-1000mm HIGH BALUSTRADES TO ALL STAIRS AND BALCONIES
-MAX 3000mm VERTICAL RISE PER FLIGHT , WINDERS WHERE SHOWN ,TO BE AT LEAST 250mm
WIDE, 450mm FROM THE NARROW END AND ANGLE BETWEEN THE RISERS TO BE CONSTANT
-MINIMUM HEADROOM TO BE 2100mm MEASURED FROM PICHLINE
-GLASS BALUSTRADES (IF SHOWN ) TO BE SAFETY GLASS

GLAZING

GLAZED EARTHENWARE
DISHED GULLEY CAST
IN CONCRETE ngl CLEANING EYE ngl -BATHROOM WINDOWS TO BE FROSTED GLASS
-ALL GLAZING ON DOORS TO BE SATETY GLASS

350 min
-ALL GLAZED AREA LESS THAN 300MM ABOVE FFL TO BE COVERED WITH SATETY GLASS

AREA SCHEDULE
pipe laid NEW FLOOR AREA =
to min 1:
40 fall
SITE PLAN AREA =

SITE COVERAGE = %

INVERT LEVEL=+450 mm.


IF LESS ENCASE IN CONC

DOORS & WINDOWS SCHEDULE


SEE SCHEDULE DRAWINGS OF DOORS AND WINDOWS

CONCRETE ROOF TRUSSES


DO NOT SCALE THE DRAWINGS
ROOF NOTES
CONCRETE ROOF TILES TO MANUFACTURE'S SPECIFICATIONS

AT 345 C/C MAXIMUM WITH '410 SISALATION' TO MANURACTURE'S


ON 114x38mm S.A PINE RAFTERS
AT 760mm C/C MAX WITH 152x38mm S.A PINE TIE BEAM
114x38mm ROOF TRUSSES
AT 760mm C/C MAX WITH 114x38mm S.A PINE WALL PLATE
ALL WEB MEMBERS TO BE 114x38mm S.A PINE GRADE SIX

50 'ISOTHERM' MINERAL WOOL INSULATION

38x38mm PINE BATTERNS


AT 345 C/C MAXIMUM
ROOF NOTES

38x38mm S.A PINE BATTERNS AT 345 C/C MAXIMUM 152x32mm TIE BEAM
ON 114x38mm S.A PINE RAFTERS AT 760mm C/C MAX (CEILING JOIST)
WITH 152x38mm S.A PINE TIE BEAM AT 50x38mmTILTING BATTERN
760mm C/C MAX WITH 114x38mm S.A PINE WALL PLATE
CONCRETE ROOF TILES
ALL WEB MEMBERS TO BE 114x38mm 38x38mm S.A BRANDERINGS
S.A PINE TO BE GRADE SIX

trusses by specialist BRICK CORBELLING 6.4mm THICK BY 900MM WIDE


CORNICE TO CLIENT CHOICE
GYPSUM CEILING BOARD FIXED
6.4mm gypsum ceiling board 6.4mm gypsum ceiling board / EQUALLY APPROAVED
ON 38x38mm BRANDERING
SPACED AT 450x900mm c/c FIXED
plaster & paint
ON 52x152mm CEILING JOIST \
plaster & paint TIE BEAM
plaster & paint INTO BRICKWORK

& PAINTED INTERIOR & EXTERIOR 10mm THICK EXTERNAL 10mm THICK INTERNAL
30mm THICK SCREED LAYED ON dpc dpc FFL dpc dpc
PLASTER PLASTER
FFL FFL
85mm THICK CONC SURFACE BED

150mm WELL COMPACTED HARDCORE 600x230mm 600x230mm


600x230mm concrete footing concrete footing 600x230mm
UNDERNEATH THE SURFACE BED concrete footing concrete footing

Potrebbero piacerti anche