Sei sulla pagina 1di 7

Datos experimentales de la práctica 6: Características de la operación de inter

de calor en paralelo y en contracorriente

Wf (L/h) 150 T1 (°C) 55 Ta (°C) 20


Pa
(L/h)
Wc T1 T2 T2' T3 T3'
80 54 43.3 44.1 41.9 38
150 54 47.7 48.4 46.2 40.1
220 54 48.4 48.8 46 45.3
280 54 49.1 49.9 47.8 47.1

Contr
(L/h)
Wc T1 T2 T2' T3 T3'
80 53 48.4 47.6 42.8 39.9
150 53 52.4 52.8 49.4 45.8
220 53 50.2 51 47.6 46.5
280 53 50.9 51.6 49.2 48.7

(L/h) Paralelo (°C)


Wc T1 T22' T33' T4 t1
80 54 43.7 39.95 37.8 22.8
150 54 48.05 43.15 42 22.9
220 54 48.6 45.65 44.3 24.2
280 54 49.5 47.45 46.1 25.8

(L/h) Intercambiador 1
Wc Tprom (°C) Tprom (K) r (g/cm3) r (Kg/L) Cp (J/gmolK)
80 48.85 322 1.0054 1.0054 75.1590
150 51.025 324.175 1.0033 1.0033 75.1397
220 51.3 324.45 1.0031 1.0031 75.1375
280 51.75 324.9 1.0026 1.0026 75.1339

(L/h) Intercambiador 2
Wc Tprom (°C) Tprom (K) r (g/cm3) r (Kg/L) Cp (J/gmolK)
80 41.825 314.975 1.0119 1.0119 75.2409
150 45.6 318.75 1.0084 1.0084 75.1932
220 47.125 320.275 1.0070 1.0070 75.1764
280 48.475 321.625 1.0057 1.0057 75.1626
(L/h) Intercambiador 1
Wc Tprom (°C) Tprom (K) r (g/cm3) r (Kg/L) Cp (J/gmolK)
80 38.875 312.025 1.0147 1.0147 75.2840
150 42.575 315.725 1.0112 1.0112 75.2308
220 44.975 318.125 1.0090 1.0090 75.2005
280 46.775 319.925 1.0073 1.0073 75.1801

(L/h) Contracorriente (°C)


Wc T1 T22' T33' T4 t1
80 53 48 41.35 35.2 25.5
150 53 52.6 47.6 42.6 25.8
220 53 50.6 47.05 43.4 25.8
280 53 51.25 48.95 45.5 25.9
e la operación de intercambiadores
acorriente

Paralelo
°C
T4 t1 t2 t2' t3 t3' t4
37.8 22.8 30.5 31.2 33.5 33.2 34.3
42 22.9 31.4 32.2 35.2 34.5 35.6
44.3 24.2 31.9 32.6 36.9 36.6 38.9
46.1 25.8 34.4 35.4 39.6 39 41.2

Contracorriente
°C
T4 t1 t2 t2' t3 t3' t4
35.2 25.5 29.4 29.2 33.1 32.9 38.4
42.6 25.8 32.7 32.4 37.8 37.3 42.5
43.4 25.8 33.7 33.6 38.5 38.2 42.7
45.5 25.9 34.6 34.4 40.3 39.8 43.7

Paralelo (°C)
t22' t33' t4 t tanque (°C) Ic If
30.85 33.35 34.3 20 16.2 11.5
31.8 34.85 35.6 20 12 12.7
32.25 36.75 38.9 20 9.7 14.7
34.9 39.3 41.2 20 7.9 15.4

1 Wc Int 1 Int 2
Cp(Kcal/Kg°C) Q (Kcal/min) (L/h) Q (Kcal/min) Q (Kcal/min)
1.0522 -14.5281 80 14.5281 5.3298
1.0520 -15.6998 150 15.6998 13.0042
1.0519 -20.8919 220 20.8919 11.4638
1.0519 -22.1477 280 22.1477 10.1244

2
Calor transferido por la corriente caliente en cada intercam
Cp(Kcal/Kg°C) Q (Kcal/min)
25.0000
1.0534 -5.3298
1.0527 -13.0042
20.0000
1.0525 -11.4638
1.0523 -10.1244 Wc
Q (kcal/min)

15.0000
Wc
Wc
10.0000
Wc

5.0000

0.0000
20.0000

Wc

Q (kcal/min)
15.0000
Wc
Wc
1 10.0000
Wc
Cp(Kcal/Kg°C) Q (Kcal/min)
5.0000
1.0540 -3.0658
1.0532 -3.0621
0.0000
1.0528 -5.2583 1 2 3
1.0525 -6.6794 Intercambiador

t22' t33' t4 t tanque (°C) Ic If


29.3 33 38.4 22 17.8 12.9
32.55 37.55 42.5 22 10.4 16.7
33.65 38.35 42.7 22 9.6 16.9
34.5 40.05 43.7 22 7.5 17.8
Nota. Se midió la columna de agua que
curbría los tubos, ya que no fue posible
llenar por completo la coraza.
t tanque (°C) Debe ser la t1 Intercambiador Longitud (cm)
20 1 54
20 2 50
20 3 49.5
20

Wc (L/h) 80 150
t tanque (°C) Longitud T (°C) t (°C) T (°C) t (°C)
22 0 54 20
22 Int. 1 54 43.7 30.85
22 In.t 2 104 39.95 33.35
22 Int. 3 153.5 37.8 34.3

Chart Title
60

50

40
Int 3
30
Q (Kcal/min) QT(Kcal/min)
3.0658 22.9237 20
3.0621 31.7661
5.2583 37.6140 10
6.6794 38.9514
0
0 20 40 60 80 100 120 140 1
e caliente en cada intercambiador

Wc (80L/h)
Wc (150L/h)
Wc (220L/h)
Wc (280L/h)
Wc (80L/h)
Wc (150L/h)
Wc (220L/h)
Wc (280L/h)

2 3
dor
tle

100 120 140 160 180