See Hydraulic Fracture Data Submission How-To Guide for max field sizes
UWI 16 character Unique Well Identifier for this Drilling event and Completion Event
WELL NAME Well Name
COMPLTN DATE Date the fracture was conducted dd-mon-year
COMPLTN TOP DEPTH (m) Top depth of interval in which fracture stage occurred in mKB
COMPLTN BASE DEPTH (m) Base depth of interval in which fracture stage occurs in mKB
COMPLTN TYPE Completion type - Single, Dual, Multi, Open Hole Barefoot (OHB)
Frac stage number - can have values such as 1, 2, 3, …19, 20 or 1A, 5A, 5B, 5C
FRAC STAGE NUM or 1TOE, 1INJ, 7INJ, or 1DFIT for DFIT/mini-frac or Injection tests for a stage
1st of 4 fields defining frac type - Base fluid can be Fresh Water, Saline Water,
BASE FLUID Oil, Acid, CO2, Propane, Surfactant, Other * see definitions below
2nd of 4 fields defining frac type - Slickwater, Linear, Crosslinked, None - ** see
VISCOSITY GEL TYPE definitions below
3rd of 4 fields defining frac type - Energized, Foam or None *** see definitions
ENERGIZER below
ENERGIZER TYPE 4th of 4 fields defining frac type - CO2, N2, CO2/N2 or None
TD or PBTD in mKB below frac stage 1, or location of last Bridge Plug, sand plug
PLUG BACK TOTAL DEPTH (m) or swell packer in mKB below each additional frac stage
ACID TYPE Type of acid used, character string, must be entered if an acid volume entered
BREAK DOWN PRESSURE (MPa) Formation break down pressure, in MPa
INST SHUT IN PRESSURE (MPa) Instantaneous Shut-in Pressure in MPa
Must enter at least one proppant type, pumped and placed. If fracture was
conducted without proppant, proppant type1 = None, 0t pumped and placed.
Proppant type examples are 100 mesh, 50/140, 40/70, 20/40, 20/40 SB Prime
PROPPANT TYPE1 etc. or None
PROPPANT TYPE1 PUMPED (t) tonnes of proppant pumped for proppant type 1, 0t if no sand
PROPPANT TYPE1 PLACED (t) tonnes of proppant placed for proppant type 1, 0t if no sand
If proppant type 2 is entered, then all type 2 data must be entered. Otherwise
PROPPANT TYPE2 all type 2 fields can be blank
PROPPANT TYPE2 PUMPED (t)
PROPPANT TYPE2 PLACED (t)
If proppant type 3 is entered, then all type 3 data must be entered otherwise
PROPPANT TYPE3 all type 3 fields can be blank
PROPPANT TYPE3 PUMPED (t)
PROPPANT TYPE3 PLACED (t)
If proppant type 4 is entered, then all type 4 data must be entered otherwise
PROPPANT TYPE4 all type 4 fields can be blank
PROPPANT TYPE4 PUMPED (t)
PROPPANT TYPE4 PLACED (t)
DEFINITIONS