Sei sulla pagina 1di 4

RAWLPLUG EasyFix PRO ver.3.3.

11

Project: Date: 16/10/2018 Page: 1/4


Subject: Organization:
Address: Address:
Designer: Contact:

Checked by: ...................................................................


Notes

Input data

Anchor type and size R-KEXII+R-STUDS-20300-A4-FL


Premium pure epoxy resin for use with metric threaded
rods - steel grade A4-70
Nominal depth (hnom) 240 mm, (hef = 240 mm)
Base material Non-cracked concrete (C35/45) temp. short/long None
Reinforcement Spacing ≥150 or spacing ≥100 with ≤Ø10
Longitudinal edge reinf. With straight edge reinforcement (≥Ø12)
Installation Hammer drilling, Installation conditions: Wet concrete
Lever arm None
Baseplate Baseplate (x = 300, y = 850 mm)
Declared thickness: tfix = 25 mm
Recommended thickness: Not checked
Material: S235 (acc. to EN 10025) fyk=235[MPa], γ=1.10
Rolled section None
Proof According to REDM and RAWLPLUG Technical Data

Design action
Vx [kN] 0.00 Mx [kNm] 0.00
Vy [kN] 270.00 My [kNm] 0.00
N [kN] 0.00 Ms [kNm] 0.00

National regulations, environmental and application conditions must be considered when designing the anchorage.
RAWLPLUG EasyFix PRO ver.3.3.11

Project: Date: 16/10/2018 Page: 2/4


Subject: Organization:
Address: Address:
Designer: Contact:

Resulting anchor forces

Anchor N [kN] V [kN] Vx [kN] Vy [kN]

1 0.000 33.750 0.000 33.750


2 0.000 33.750 0.000 33.750
3 0.000 33.750 0.000 33.750
4 0.000 33.750 0.000 33.750
5 0.000 33.750 0.000 33.750
6 0.000 33.750 0.000 33.750
7 0.000 33.750 0.000 33.750
8 0.000 33.750 0.000 33.750
Max. concrete compressive stress: 0.00 [N/mm²]
N - Tension force
V - Shear force
Vx - Shear force x
Vy - Shear force y

National regulations, environmental and application conditions must be considered when designing the anchorage.
RAWLPLUG EasyFix PRO ver.3.3.11

Project: Date: 16/10/2018 Page: 3/4


Subject: Organization:
Address: Address:
Designer: Contact:

Shear load (according to REDM)

Steel failure Steel failure (with lever


Concrete pry-out failure Concrete edge failure
(without lever arm) arm)
N0Rk,c [kN] 251.91 V0Rk,c [kN] 62.32

k1 10.10 k1 2.40

Ac,N [mm²] 1,007,400.00 Ac,V [mm²] 249,750.00


0 0
A c,N
[mm²] 518,400.00 A c,V
[mm²] 101,250.00

c1 [mm] 150.00

ccr,N [mm] 360.00 Ψα,V 2.50

scr,N [mm] 720.00

Ψs,N 0.83 Ψs,V 1.00

Ψre,N 1.00 Ψre,V 1.00

Ψec,N 1.00 Ψec,V 1.00


eNx [mm] 0.00 eVx [mm] 0.00

eNy [mm] 0.00 eVy [mm] 0.00

k 2.00 Ψh,V 1.00

VRk,s [kN] 86.00 VRk,cp [kN] 807.73 VRk,c [kN] 384.28

γMs 1.56 γMc 1.50 γMc 1.50

VRd,s [kN] 55.13 VRd,cp [kN] 538.49 VRd,c [kN] 256.19

VSd [kN] 33.75 VSd [kN] 270.00 VSd [kN] 135.00

βV1 61.3 βV2 ND βV3 50.2 βV4 52.7

Combined tension and shear loads

βN [%] βV [%] Utilisation [%] = βV

ND 61.3 61.3
Utilisation 61.3% - correct connection

Hints for the calculations and the program

- Responsibility for compliance with current standards lies with the user.
- Calculation method assumes that the shear force is distributed over all anchors. As such the gaps between the anchors
and the fixture element should be filled in, for example, by filling gaps using resin with adequate compressive strength.

National regulations, environmental and application conditions must be considered when designing the anchorage.
RAWLPLUG EasyFix PRO ver.3.3.11

Project: Date: 16/10/2018 Page: 4/4


Subject: Organization:
Address: Address:
Designer: Contact:

Installation data for R-KEXII+R-STUDS-20300-A4-FL

Thread diameter d [mm] 20.0


Hole diameter in substrate d0 [mm] 24
Min. hole depth in substrate h0 [mm] 245
Nominal depth hnom [mm] 240
Min. substrate thickness hmin [mm] 288
Installation torque Tinst [kNm] 0.12
Anchor length L [mm] 300
Fixture thickness tfix [mm] 25
Hole diameter in fixture df [mm] 22
Amount of resin per one mount - [m³] 1
Fill in the gaps between the anchors and the fixture element, for example, using resin with adequate compressive
strength.

National regulations, environmental and application conditions must be considered when designing the anchorage.