SCHEDULE OF QUANTITY Estimated Cost:- Rs.

1098540
Name of work:- Installation of tube well 125 mtr. Deep including drilling lowering and Earnest Money:- Rs. 21971
development near pump house Kalehli in Tehsil & Distt. Kullu (HP) Time 6 Months

Sr.No Sub head and item of work Qty Rate Unit Amount
1 Transportation of Rig alongwith allied accessories etc.Complete including erection and Job -
levelling at site through all kinds of roads approaches field etc.in all leads lifts upto site of work
complete in all respect as per the direction of the Engineer-in-Charge
2 Earth work in foundation for digging Tubewell in all kinds of soils including dewatering shoring 5 Cum
struting from GL upto 5 mtrs including disposing excavated soil in all leads and lifted
complete in all respect as per the directions of Engineer-in-Charge. 0.5 mtrs
3 Drilling of bore as per specifaction laid down in IS 2800-1991 (part-I) with upto date
ammedments if any with percasion Rig of combination drilling Rig starting with 950-600 mm
dia MS pipe reduced to 450-400 mm dia MS Pipe cofirming to IS 4270-2001 with upto date
amendments if any in all kind of soil boulders rocks, collapsible strata, saturated soils
artesian conditions including the cost of all consumable, stores, water, fuel, lubricants and
other accessories etc. complete in all resspects as per the directions of the Engineer-in-
charge.
i) Drilling & lowering of MS casing pipes conforming to IS 4270-2001 with upto date
amendments if any of suitiable sizes as mentioned above from 5-30 mtrs. Below ground level
within all leads and lifts.
,5-25 20 Mtr.
25-30 5 Mtr.
ii) Drilling & lowering of MS casing pipes conforming to IS 4270-2001 with upto date
amendments if any of suitiable sizes as mentioned above from 30-60 mtrs. Below ground level
within all leads and lifts.
30-50 20 Mtr.
50-60 10 Mtr.
iii) Drilling & lowering of MS casing pipes conforming to IS 4270-2001 with upto date
amendments if any of suitiable sizes as mentioned above from 6-100 mtrs. Below ground level
within all leads and lifts.
60-100 40 Mtr.
iv) Drilling & lowering of MS casing pipes conforming to IS 4270-2001 with upto date
amendments if any of suitiable sizes as mentioned above from 100-125 mtrs. Below ground
level within all leads and lifts.
100-125 25 Mtr.
4 Collection preservation and display of suitable size sample box with top lid and locking 1 No Each
arrangement till handing over of tube well to the department complete in all the respect as per
direction of the Engineer-in-Charge
4(a) Supply and lowering of IS marked Electric Resistance Welded MS pipe 300 mm dia nominal 45 Mtr
size housing, 8mm thick having out side dia mtrs.323.9mm screwed end socketed confirming
to IS 4270-2001 with up-todate amendments if any about 4 mtrs to 7 mtrs in length welded
without any circumferential joints into bore hole in vertical position including cost of all
scaffolding derricks poles clamps embedded in foundation etc. including cost of all cutting
threading and welding of pipes etc. within all leads and lifts complete in all respects as per the
directions of the engineer-in-Charge.
(b) S/Lowering at site Electrict resistance Welded (ERW) Stainless Steel Cage type "V" Wire 15 MTR
wound screens of size 300 mm & 8mm thick with slot opening 1.0 mm as per IS 8110-2000
with upto date amendments if any and material spefication as per AISI" Americal Iron and
Steel ins type Grade SS-304 in suitable length as per site conditions including the cost of SS
socket 8mm thickness ( Supplied by the Deptt) of the length 140mm conforming to AISI grade
304 , suitable to accommodate screen and ring including jointing screen with blind pipes
compleed in all reapect all scaffoiding derricks, poles clamps embedding in foundation etc.
including cost of all cutting threading and welding of pipes etc. within all leads and lifts
complete in all respects as per the direction of othe Engineer-in- charge Screen will be
continuous trapezoidal wire spirally wound around fabricated cage the wrapping wire having a
"V" shaped (Wedge) profile wire with flat surface on the outside and prooducing expanding
slots on the inside of
var

5 Proving and fixing MS taper/reducer as per length approved by Engineer-in-charge the 1 Each
material of MS taper/reducer shall be equivalent to parent pipe material and shall conform to
chemical composition as per clause 5 2 and mechanical properties as per clause 61 and
table 1 of IS 4270-2001 with upto date amendments if any complete in all respects as per
directions of Engineer-in-Charge.
6(a) Supply and lowering of IS marked Electric Resistance Welded MS pipe 200 mm dia nominal 67 Mtr
size housing, 6.4mm thick having out side dia mtrs.219.10mm screwed end socketed
confirming to IS 4270-2001 with up-todate amendments if any about 4 mtrs to 7 mtrs in length
welded without any circumferential joints into bore hole in vertical position including cost of all
scaffolding derricks poles clamps embedded in foundation etc. including cost of all cutting
threading and welding of pipes etc. within all leads and lifts complete in all respects as per the
directions of the Engineer-in-Charge.
(b) Lowening at site Electric Resistance Welded (ERW) Stainless Steel cage type "V" Wire 8 Mtr
wound screens of size 200 mm 6.30mm thick with slot opening 1.0 mm as per IS 8110-2000
with upto date amendments if any and material spefication as per AISI" Americal Iron and
Steel inst type Grade SS-304 in suitable length as per site conditions inculding the cost SS
socket 8 mm thickness (supplied by the department) of length 140mm conforming to AISI
grade 304 , suitable to accommodate screen and ring including jointing screen with blind pipes
complete in all reapect all scaffoiding derricks, poles clamps embedding in foundation etc.
including cost of all cutting threading and welding of pipes etc. within all leads and lifts
complete in all respects as per the direction of othe Engineer-in- charge Screen will be
continuous trapezoidal wire spirally wound around fabricated cage the wrapping wire having a
"V" shaped (Wedge) profile wire with flat surface on the outside and producing expanding
slots on the inside of various

7 Pdg.and fixing MS cetralized guides at suitable specing for each tube well as per IS 226- 5 Each
1991 with up-to-date amendments, if any within all leads and lifts 1x4 nos.completed in all
respects as per the directions of the Engineer-in-charge
8 Spplying lowering and fixing in position IS marked mild steel bail plug of 200mm/300mm 1 Each
diameters with "U"hooks as per IS 2800-1991 with up to date amendements, if any within all
leads and lifts complete in all respects as per deriction of the Engineer-in-Charge

9 Pdg.and fixing in position threaded iron cap with locking arrngements of apporoved design to 1 Each
prevent foreign matter from getting into bore hole as required with in all leads and
lifts,complete in all respects as per directions of the Engineer-in-Charge.
10 Supplying and packing of gravel, consisting of hard quartz or other suitable material with in 125 Mtr
average pecific gravity of onot less than 2.5, not containing more than 2% by weight of thin flat
of elangated pieces, shalll be of sub rounded to rounded grains with minimum angular
features of size 2-3.35 mm shall be free from impurities such as shafe, shale, mica felspar
clay, sand, dirt loam, baematte and organic materiial as per IS 4097- 1967 with upto date
amendments, if any, around intake of tubewell with minimum thickness of shroud around
screen generally 100mm to the entire depth of the bore as per 2800(Part-I) 1991 with upto
date amendments, if any, within all leads and lifts complete in all respects as per the direction
of the Engineer-in-Charge.
11 Extration of all sizes blind/casing pipes with machine starting from the bottom of the bore hole
within all leads and lifts, complete in all respects as per direction of the Engineer-in- Charge
as follows
(a) In contact with Soil 125 Mtr
(b) Frely hanging 165 Mtr
12 Development of tubewell by back washing method with air compressor of minimum 750 CFM 30 P/hour
capacity pumping pipe of 200mm size and air line of minimum 65 mm size or with other
suitable method till the well is throughly developed as per clause 4.2 of IS 11189-1985 with
upto date amendments if any complete in all respects as per direction of the Engineer-in-
Charge.
13 Development of tubewell by continuous over pumping method with VT pump/Submerssible 20 P/hour
pumps of suitiable capacity not less than double the discharge established by the compressor
method/ design discharge untill the well is sand free as per IS-11189-1985 uptodate
amendments if any, complete in all respects as per directions of the Engineer- in-Charge. The
draw down and discharge to be established by running the VT/ Submerssib le pump
contineously for 8 hours in presence of officer not less than the rank of Assistant Engineer.

14 Testing the verticialy of the tubewell as per clause 4-3 of IS 2800 (Part-II) 1979 with upto Job Job
date amendments, if any, using plumb or plunger 6 mm smaller in dia within the inside
diameter of the well casing. The results of the vertiicality test shall be recorded on proforma
shown in Appendix A of IS 2800 (Part-II) 1979 with uptodate amendments, if any, as
appended with the tender documents and handed over complete in all respect as per
directions of the Engineer-in- Charge.
15 Dismentalling of Rig or other allied accessories after completion of job within all leads and Job Job
lifts, complete in all respects as per the directions of the Engineer-in - Charge.

16 Construction of barbed, wired enclosure of minimum of size 2.5x2.5m to safe guard the bore 4 Each
of tubewell with angle iron of size 40x40x6mm 1.5 mtrs in height, ambeeded in concrete block
of 30x30x30 cm in all leads and lifts complete in all resspects as per the directions of the
Engineer-in- Charge.
17 Handing over of the tube well in complete shape as per appendex "B" of clause 7 of IS 2800 Job Job
(Part- II)- 1979 with upto date amendments if any as appended with the tender documents, in
laminated form in triplicate compelte in all respect as per the directions of the Engineer- in-
Charge.

Terms and conditions :-


1. Work should be done as per PWD /IPH specifications
2. Nothing shall be paid for rejected work/ materials
3. Drilling of Tube well shall be as per specification laid down in IS 2800 -1991 (part-I) with
percusion or condition)
4. MS pipe shall be confirming ot IS 4270- 1997 in all kinds of soil Executive Engineer
5 The contractor will be responsible for watch and ward of materials at site. Irrig.and PH Division,
No.II Kullu at Bhuntar.

Potrebbero piacerti anche