Inspection Report
Continued
Client: Haifa Industrial Services Co LLC PO No.: 18000026 Page 2 of 3
1.Report Headings: 2.Persons Present 3.Documentation Used /Approval Status 4.Inspection Carried Out 5.HSE Feedback
on the Vendor 6.Results/Conclusions 7.Overall Order Status 8.Next Visit/Exit Call 9.Attachments/Photos
Witnessed Burst Test for the below mentioned cylinders with Achieved Result :-
Burst Standard
Cylinder
Pressure
Capacity Serial No.
Achieved
(Liter)
(Bar)
26.5 A 89977 102.62 BS EN 1442 : 2006
26.5 A 90470 102.12 BS EN 1442 : 2006
26.5 A 90980 101.62 BS EN 1442 : 2006
26.5 A 91483 102.62 BS EN 1442 : 2006
26.5 A 91974 103.62 BS EN 1442 : 2006
26.5 A 92483 103.62 BS EN 1442 : 2006
26.5 83565 100.12 ISO 22991:2008
26.5 84070 103.62 ISO 22991:2008
26.5 84565 102.12 ISO 22991:2008
Mechanical Tests & Burst test pressure value for above all meets the standard requirements -
Found accepted.
Verified & Reviewed calibration certificate of pressure gauge – Found valid.
1.Report Headings: 2.Persons Present 3.Documentation Used /Approval Status 4.Inspection Carried Out 5.HSE Feedback
on the Vendor 6.Results/Conclusions 7.Overall Order Status 8.Next Visit/Exit Call 9.Attachments/Photos
Date
N.A N.A N.A N.A
8.0 NEXT VISIT / EXIT CALL (must give estimated date if no fixed date; include stage/activity details): TBA
- End of Report -