Bangalore
By
Roshan Rakesh Adithiyan Prabu
INTRODUCTION
•Staring at a very huge piece of rock, the architect of this unique hotel saw three
things during his first site visit. Stone. Grass. And Sky.
•The three elements - stone, grass and sky combine to create a feeling that
captures a stylish vibe. Discover it in the lobby. Spot it cascading by the poolside.
Design
Concept:
A Sense of Drama & Discovery!
Created by WOW
Architects/Warner Wong Design,
Singapore
Designed as a flowing land-
scrapper that blends earth to sky
Spaces flow and connect to each
other encouraging exchange and
interaction.
Façade changes color, texture &
tone to express the borderless
potential of its guests
Site Analysis
North Point
• PROVIDED/ INFERENCE:-
• Wi-Fi printer
• Comb binding
• lamination
• Photocopier
• Fax
• Internet access
• 2 PCs
• Night vision cameras
• Two meeting rooms for 8 and 6 people
respectively.
SMELL THE COFFEE AT LATITUDE – THE ALL DAY DINER
OR STEP OUT AND REACH FOR THE SKIES ……. CASCADE
RELAX & ENERGIZE AT CELSIUS – THE POOL
Relax & Energize at Celsius – the pool
• Open 24-hours
• Equipped with Life Fitness circuit training and
cardio machines
• Yoga & Aerobics in an exclusive area adjacent to
the gym
FITNESS ROOM
A WHIFF OF ROMANCE AT
THE PATIO AT TERRACOTTA
MEET AT TANGO, THE BANQUET HALL
BANQUET ROOM
STANDARD:-
PROVIDED/INFERENCE:-
BOILER 50-100-150
SWITCH ROOM/ METER ROOM/ HV 100-150-200
SUBSTATION
ELECTRICAL
• DG:-
1. THEY HAVE USED 750 KVA CAPACITY OF 2 NO.S
2. STANDARD SIZE FOR DG ROOM SHOULD BE 10700MM(L) X
7700MM(W) X 6100MM(H).
3. THEY HAVE ADEQUATE AMOUNT OF SPACE FOR THIS ROOM.
• TRANSFORMER:-
1. THEY HAVE PROVIDED 1000KVA CAPACITY OF TWO NO.S
2. STANDARD SIZE FOR 1000KVA ROOM IS 5M X 5M.
3. THEY HAVE PROVIDED ADEQUATE SPACE FOR TRANSFORMER.
• HT AND LT ROOMS:-
1. STANDARD ROOM SIZE FOR H.T SHOULD BE 4M X 4M.
2. STANDARD LT ROOM SIZE SHOULD BE 4M X 6M.
3. THEY HAVE PROVIDE ADEQUATE SPACE FOR BOTH THESE
ROOMS.
AC PLANT ROOM
• THEY HAVE PROVIDED 3 NO.S OF 250 TR .
• STANDARD ROOM SIZE= (8M X 6M X 3.5M)
• THEY HAVE PROVIDED ADEQUATE SPACE
FOR THIS ROOM.
AHU ROOM
1. STANDARD ROOM SIZE (3.2 X 3.6 M) MIN
2. THEY HAVE PROVIDED ADEQUATE ROOM
SIZE FOR AHU SPACES.
SEPTIC TANK/ STP PLANT
• STANDARDS:-
1. TOTAL CAPACITY OF SEPTIC TANK (C) = (180
X P)+ 2000.
• PROVIDED/INFERENCE:-
1. POPULATION=1100
2. C= (180 X 1100) + 2000 = 200KL.
3. PROVIDED STP PLANT CAPACITY IS 200KL.
4. THEY HAVE FOLLOWED THE STANDARDS.
FIRE SAFETY MEASURES
• STANDARDS:-
1. FOR BUILDING WHICH IS 15M- 30M HIGH FOLLOWING
PROVISIONS SHOULD BE MADE.
HOUSE REEL, WET RISER, DOWN COMER, YARD
HYDRANT, AUTOMATIC SPRINKLER SYSTEM,
MANUALLY OPERATED FIRE ALARM SYSTEM &
AUTOMATIC DETECTION ALARM SYSTEM.
2. FIRE EXITS SHOULD BE PROVIDED AT EVERY 30M
DISTANCES.
3. FIRE CONTROL ROOM SHOULD BE 4M X 4M.
4. UNDERGROUND WATER STORAGE CAPACITY SHOULD
BE 100000 LTRS.
5. FIRE PUMP ROOM SHOULD BE 10M .IN LENGTH MIN.
• PROVIDED/INFERENCE:-
ALL THE ABOVE PROVISIONS ARE MADE IN THIS
HOTEL.
LIFTS
• STANDARDS:-
1. HOTEL SHOULD PROVIDE ATLEAST 2 PASSENGER LIFTS
( MANY MORE CAN BE INCLUDED TO MAXIMIZE GUEST
CONVINIENCE.)
2. MINIMUM 1 NO. OF SERVICE LIFTS SHOULD BE
PROVIDED.
3. THE LIFT LOBBY SHOULD BE 1.5 -2 TIMES THE CAR SIZE.
4. FOR 13 PASSENGER LIFT IT SHOULD BE 2.5 X 1.9.
• PROVIDED/INFERENCE :-
1. THEY HAVE PROVIDED 4 PASSENGER LIFTS AND 4
SERVICE LIFTS.
2. FOR 13 PASSENGER LIFT THEY HAVE PROVIDED 2.5X1.9.
HENCE THEY HAVE FOLLOWED STANDARDS.
FORM ANALYSIS
SENSORY ASPECTS – SPECIAL VIEWS
SPECIAL VIEW