MICROPROCESSOR BASED

FIRE PUMP CONTROLLERS


An Introduction to NAFFCO
National Fire Fighting and Manufacturing FZCO (NAFFCO) CCTV, ambulances, extendable mobile hospitals, platform vehicles,
is amongst the world’s largest manufacturers and full solution rescue vehicles, fire trucks, and most advanced Airport Rescue &
providers of Fire Fighting equipment, fire protection systems, fire Fire Fighting (ARFF) vehicle.
alarm, security systems and safety engineering under one roof.
Taking into consideration the increasing market demand for sever-
Dedicated to the science of fire fighting, NAFFCO was established al products and services, NAFFCO expands its venture in the pas-
with a vision to be the world’s most recognized fire Protection sive fire protection, CCTV, fire alarm, and security systems. Some
Company through quality and development to save lives and of the recent expansions include the launching of new manufactur-
properties. Headquartered in Dubai, UAE, NAFFCO has spanned ing divisions for fire - rated doors and HDPE pipes and fittings.
the globe by serving over 108 countries worldwide.
NAFFCO is associated with the globally renowned international
The numerous projects executed by NAFFCO in both the private companies in the fire protection industry such as Esser, Secu-
and government sectors throughout the globe are classic examples tron, Megalights, Evax, Fike, Central, Shield, Mueller, Giacomini, RB
of its professional competency. These projects include residential Pumps, Bombas, Ideal Pumps, Joslyn Pumps, Peerless Pumps and
buildings, commercial edifices (e.g. schools, hospitals, malls, sports more.
stadiums, etc.), industrial manufacturing plants, power generation
stations, and oil and gas facilities. As a provider of total fire protec- The company is well known for its very strong engineering team
tion systems, NAFFCO undertakes turnkey projects from design, that ensures that their innovative designs are based on the stand-
supply, installation, testing and commissioning of various systems ards of the National Fire Protection Association (NFPA). It also has
like fire detection, fire alarm, fire suppression, and fire fighting sys- an equally competent and dedicated maintenance team that pro-
tems which our customers find it very convenient to have all their vides a 24/7 service to ensure the efficiency of the fire protection
system requirements under one roof provided by NAFFCO. systems for its clients. NAFFCO offers annual and semi - annual
maintenance contracts. Moreover, we also provide after - sales ser-
NAFFCO has been consistently maintaining ISO 9001 Quality Man- vice, spare parts and training.
agement System certified by UL, BV and LPCB. The company
also has got certified for ISO 14001 Environmental Management In recognition to the success of its business growth, NAFFCO has
systems and BS OHSAS 18001 for Occupational safety by UL DQS. been awarded with the prestigious Mohammed Bin Rashid Al Mak-
toum Business Award for excellence in exports in 2005 and for
NAFFCO implemented top notch ERP “Oracle” Systems by adopt- excellence in manufacturing in 2006 and 2010. Furthermore, NAF-
ing best business practices to enhance efficiency and transparency FCO received the Dubai Quality Appreciation in 2008 which bears
by controlling key operations with continuous improvement. witness to its constant focus towards business excellence and the
quality of services it provides.
The company’s reputation for quality and reliability is globally ac-
claimed. Its innovative fire protection and fire fighting products are NAFFCO’s mission is to empower customer to secure life, property
certified by international bodies like LPCB, BSI, SAI Global, UL and and business by delivering high quality and innovative fire protec-
FM. Its product range includes different kinds of fire extinguishers, tion solutions and knowledge using world class manufacturing pro-
custom - made fire cabinets, heavy - duty fire hoses and reels, high cesses through best engineering practice and expand it worldwide.
capacity powerful fire pumps, mobile fire fighting systems includ-
ing CAF systems, fire - rated doors, fire detection & alarm systems,

2 www.naffco.com
UL LISTED ELECTRIC MOTOR
MICROPROCESSOR BASED CONTROLLER
MODEL NFY-SDM1 REDUCED VOLTAGE/
STAR – DELTA (OPEN TRANSITION)
MODEL NFY-DOM1 DIRECT ON LINE
NAFFCO Electric Motor Controllers for fire pumps are listed Power ratings vary from 40 to 400 horsepower, 230 /
by Underwriters Laboratories (UL file number EX15064), 380 / 415 VAC, 50/60 Hz.
in accordance with UL218 (Standard for Fire Pump Con-
troller), UL508a (Standard for Industrial Control Panel), Only high quality UL listed or UL recognized compo-
NFPA20 (National Fire Protection Association Pamphlet nents are used in these panels to guarantee the best
20- Standard for Centrifugal Fire Pumps), NFPA70 (Na- possible reliability. Also high quality UL listed enclo-
tional Electric Code) and NEMA. sures are used.

Also approved by FM approvals (Factory Mutual), in ac- This controller is completely wired, assembled, pro-
cordance with FM standard 1321 / 1323 (Standard for Fire grammed and tested at the factory before shipment,
Pump Controller). and ready for immediate installation.

STANDARD FEATURES
• 230 / 380 / 415 VAC, 50/60 Hz main 3 phase system
power.
• Voltage Surge Protector.
• Main disconnecting switch with rotary handle sized for
disconnecting motor horsepower and voltage.
• Circuit breaker with shunt trip coil and rotary handle.
• Rated motor contactors.
• Emergency run mechanism to mechanically close motor
contactor contacts to start motor in case of emergency
cases.
• Manual start and stop push buttons.
• 20x4 LCD display showing all system parameters and
variables.
• User friendly software enable user to program all related
parameters like timers, pressure, inputs, outputs … etc.
• Showing 3 phase line voltages.
• Showing 3 phase line motor currents.
• Showing real value of discharge pressure.
• Showing motor running hours.
• Showing ambient temperature.
• Starting delay timer (programmable) for sequence multi-
ple pumps starting.
• Automatic or manual shutdown after automatic start (se-
lectable).
• Automatic shutdown mode enabled/disabled indicator.
• Power ON/Healthy indicator.
• Automatic mode indicator.
• Manual mode indicator.

www.naffco.com 3
STANDARD FEATURES
• Motor Run indicator/free contact. • Remote start on alarm / indicator / free contact (pro-
• Phase Loss/Failure alarm / indicator / free contact. grammable).
• Phase sequence error alarm/indicator / free contact. • Manual local start on alarm/ indicator / free contact
• System error alarm / indicator / free contact. (programmable).
• Fail to start alarm / indicator. • Fail while run alarm / indicator / free contact (pro-
• System error alarm / indicator. grammable).
• Pump lockout indicator / free contact. • Emergency start on alarm / indicator / free contact
• Push button for alarm silence (programmable).
• (only for additional alarms). • Test on alarm/ indicator / free contact (programma-
• Motor locked rotor trip at 600% of FLA, after program- ble).
mable time delay. • 10 additional programmable indicators (LED’s).
• Programmable automatic test, which can be pro- • 10 additional programmable auxiliary digital inputs.
grammed to start at any desired day, hour and minute • 7 additional programmable output relays (free con-
• in the week. tacts).
• Manual test push button. • Pressure transducer with analog voltage output.
• Motor overload alarm/ indicator / free contact (program- • Data logging system for pressure and events.
mable). • USB port for saving recorded pressure and events
• Over voltage alarm/indicator / free contact (program- on USB memory, and can be viewed with MS
mable). • word and Excel.
• Under voltage alarm/ indicator / free contact (program- • Electrically actuated built in discharge solenoid valve.
mable). • Electrical alarm bell.
• Low discharge pressure alarm / indicator / free contact • UL listed enclosure.
(programmable).
• Deluge valve on alarm / indicator / free contact (pro-
grammable).

Fig (1)

MOTOR STARTING CHARACTERISTICS: DOL AND STAR-DELTA

4 www.naffco.com
SEQUENCE OF OPERATION AUTOMATIC MODE
This controller is working under both automatic and • In this mode, if pressure goes down till the cut-in pres-
manual modes with manual or automatic shut down sure point then motor will start automatically.
(automatic shut down is possible only after automatic • If the N/C contact of the deluge valve is opened, this
start). will cause the pump to start automatically exactly as if
the pressure goes down to starting pressure.
MANUAL MODE • In case of multiple pumps, it may be necessary to de-
• In this mode, there will be no effect of pressure sensor lay the starting of each motor to prevent simultane-
and deluge valve. ous starting of all motors. Sequential starting can be
• Manual start of motor can be done by pressing start P.B. adjusted by a programmable timer. User has to
• Manual start can also be done by pushing emer- specify if the pump is connected as single/parallel
gency start mechanical handle. with other pumps, or if the pump is connected in
• This handle provides direct on line continuous starting series with other pumps (programmable). In the
• In this mode motor can be stopped only manually by first case (single or parallel), system may delay start-
pressing Stop P.B. ing in automatic mode only, but starting in manual
• All alarm signals are operational in this mode. mode will not be delayed. In the second case (se-
ries), system may delay starting in automatic mode
and in manual mode, and this is to avoid dry running
of pump (see table 1) Notice that in case no time delay
is required before starting (for example when pump is
single), then time delay can be programmed to zero.

www.naffco.com 5
TIME DELAY BEFORE STARTING THE FIRE PUMP

REASON OF STARTING SINGLE PUMP OR PARALLEL PUMPS SERIES JUMPS

Drop in pressure With delay With delay

Deluge valve With delay With delay

Remote start No delay With delay

Manual start No delay With delay

Table (1)

• If remote start switch was momentarily actuated, • Two ways of shutdown are possible in this mode (op-
motor will start directly and automatically, and it will erator have to select one of them by software):
not stop unless operator presses stop push button on
the panel’s door. In this mode (remote start mode) there 1. Manual shutdown: After automatic start, motor can
will be no effect of deluge valve signal and low pressure be stopped in this mode only by pressing manual
stop push button. If the pump was on demand (low
signal. pressure or deluge valve active), and in auto mode,
• Motor automatic start by pressure sensor and deluge then pump cannot be stop manually, unless it is not on
valve can be disabled by pump lockout contact (exter- demand any more.
nal contact) which can be connected with controller (this 2. Automatic shutdown: After automatic start, control-
ler will keep motor running for a period (pro-gramma-
option can be used in case of having a stand-by pump, ble). After that, if the pump was not any more on
where it is not desired both pumps to start automatically demand, then controller will automatically shutdown
at the same time). the motor. If within this period, the pump became not
on demand, operator can shut it down manually by
pressing manual stop push button.

METHODS OF STOPPING THE FIRE PUMP

REASON OF STARTING AUTOMATIC STOP MANUAL STOP

YES - selectabl
Drop in pressure YES - selectable
(After running hold time)
YES - selectable
Deluge valve YES - selectable
(After running hold time)
Remote start NO YES
Manual start NO YES

Table (2)

• All alarm signals are operational in auto mode. • Manual test is operational in auto mode only, and it
• Automatic weekly test is only operational at auto can be applied by pressing test ON/OFF push button.
mode and can be enabled or disabled (operator selec- Test can be terminated by pressing Test ON/OFF push
tion). If enabled, then user has to program the delay time button again.
before starting the test. Also to program the day,
hour and minute where the weekly automatic test is
desired to start. Test can be terminated by pressing Test
ON/OFF push button.

6 www.naffco.com
FUNCTIONALITY
• During operation of the system, controller will be • If the controller closed contactors to start the motor
reading voltages, currents, pressure, and sensing many (due auto or manual start), but the motor didn’t start
input signals. These reading can be monitored on the after some delay (programmable time delay), then
LCD display. controller will give alarm (fail to start alarm). Control-
• If controller detected loss of one phase or more, then it ler will sense if motor started or not by sensing the
will give an alarm and will prevent the motor from start- motor current.
ing, but if the loss of phase happened while the motor • If the controller closed contactors to start the motor
was running, then controller will give alarm butwill not (due auto or manual start), but the motor didn’t start
stop the motor. after some delay (programmable time delay), be-
• If controller detected phase reversal, it will give alarm cause of LOCKED ROTOR, then controller will ac-
and will not start the motor. tivate the shunt trip coil of the MCCB and shut it
• Controller will detect over voltage, under voltage and down. Controller will sense if motor is in locked rotor
overload (over current), and will give alarms showing situation or not by sensing the motor current.
these errors.

RATING

RATED SHORT CIRCUIT


POWER RATED VOLTAGE FREQUENCY ENCLOSED SIZE
CONTENT CURRENT
(HP) (VAC) (Hz) (mm)
(A) (kA)

40 380 - 415 50 or 60 66 100kA 1100(L) x 750(W) x 300(D)

50 380 - 415 50 or 60 83 100kA 1100(L) x 750(W) x 300(D)

60 380 - 415 50 or 60 103 100kA 1100(L) x 750(W) x 300(D)

75 380 - 415 50 or 60 128 100kA 1200(L) x 800(W) x 300(D)

100 380 - 415 50 or 60 165 100kA 1200(L) x 800(W) x 300(D)

125 380 - 415 50 or 60 208 100kA 1200(L) x 800(W) x 300(D)

150 380 - 415 50 or 60 240 100kA 1500(L) x 800(W) x 350(D)

200 380 - 415 50 or 60 320 100kA 1500(L) x 800(W) x 350(D)

250 380 - 415 50 or 60 403 50kA 1500(L) x 800(W) x 350(D)

300 380 - 415 50 or 60 482 50kA 1500(L) x 800(W) x 350(D)

350 380 - 415 50 or 60 560 50kA 1700(L) x 950(W) x 400(D)

400 380 - 415 50 or 60 636 50kA 1700(L) x 950(W) x 400(D)

Table (3)

www.naffco.com 7
UL LISTED DIESEL ENGINE
MICROPROCESSOR BASED CONTROLLER
MODEL NFY-DM1
NAFFCO Fire Diesel Engine Controller are listed by Un- volts DC operating voltage, 110 / 220 volts AC input
derwriters Laboratories (UL file number EX15064), in voltage, 50/60 Hz. These controllers are compatible
accordance with UL218 (Standard for Fire Pump Con- with most types of fire fighting diesel engines.
troller), UL508a (Standard for Industrial Control Panel),
NFPA20 (National Fire Protection Association Pamphlet Only high quality UL listed or UL recognized compo-
20 – Standard for Centrifugal Fire Pumps), NFPA70 (Na- nents are used in these panels to guarantee the best
tional Electric Code) and NEMA. possible reliability. Also high quality UL listed enclo-
sures are used.This controller is completely wired, as-
Also approved by FM approvals (Factory Mutual), in sembled and tested at the factory before shipment,
accordance with FM standard 1321 / 1323 (Standard for and ready for immediate installation.
Fire Pump Controller). Power ratings suitable for 12/24

STANDARD FEATURES
• System error alarm / indicator.
• AC power healthy indicator.
• DC power healthy indicator / free contact.
• Speed switch error or failed while running alarm /
indicator.
• Automatic shutdown enabled/disabled indicator.
• Low discharge pressure alarm / indicator / freecon-
tact (programmable).
• Deluge valve on alarm / indicator / free
contact(programmable).
• Remote start on alarm / indicator / free
contact(programmable).
• 10 additional programmable indicators.
• 11 additional programmable digital inputs.
• 8 additional programmable output relays (free con-
tacts).
• Common alarm free contact.
• Electrical alarm bell.
• Push button for alarm silence (only for additional
alarms).
• Pressure transducer with analog voltage output.
• Data logging system for pressure and events.
• USB port for saving recorded pressure and events
on USB memory, and can be viewed with MS word
and Excel.
• Electrically actuated built in discharge solenoid valve.
• UL listed enclosure.
• 220 / 110 VAC main line system power.
• 12 / 24 VDC system control voltage.
• Automatic / Manual / OFF mode (selectable).
• Two 12 / 24 VDC, 10 Amps smart automatic micropro-
cessor battery chargers.
• Protection circuit breakers before and after battery-
chargers.
• 20x4 LCD display showing all system parameters and
variables.
• User friendly software enable user to program allrelat-
ed parameters like timers, pressure, inputs,outputs …
etc.
• Showing battery 1 and 2 voltages.
• Showing battery 1 and 2 charging currents.
• Showing real value of discharge pressure.
• Showing engine running hours.

8 www.naffco.com
STANDARD FEATURES
• Showing ambient temperature. • Engine run indicator / free contact.
• Automatic cranking from two different batteries. • Test running indicator / free contact.
• Two push buttons for manual cranking from two dif- • Automatic mode indicator / free contact.
ferent batteries. • Manual mode indicator.
• Manual stop push button. • Battery Charger1 error indicator.
• Programmable automatic weekly test, which can • Battery Charger2 error indicator.
be programmed to start at any desired day, hour • Battery1 failure alarm / indicator.
and minute in a week. • Battery2 failure alarm / indicator.
• Manual test push button. • Low oil pressure alarm / indicator.
• Starting delay timer (programmable) for sequence • High water temperature alarm / indicator.
multiple pumps starting. • Over speed shut down alarm / indicator.
• Automatic or manual shutdown after automatic start • Engine failed to start alarm / indicator.
(selectable). • Cranking coil 1 failure alarm / indicator.
• Compatible with fuel solenoid engines and stopped • Cranking coil 2 failure alarm / indicator.
solenoid engines.

SEQUENCE OF OPERATION OFF MODE


This controller is working under three modes; automatic, • In this mode starting diesel engine is not possible in
off (reset) and manual mode, with manual or auto- any case.
matic shut down (automatic shut down is possible • Automatic test and manual test are not operational.
only after automatic start). • Alarm bell is not enabled in this mode, but alarm indi-
cators are enabled.
• This mode also is used to shutdown the engine.
MANUAL MODE
• In this mode, there will be no effect of pressure sensor,
deluge valve or remote start. AUTOMATIC MODE
• Manual direct cranking can be actuated by pressing on • In this mode, if pressure goes down till the cut-in
battery 1 manual cranking P.B, or on battery 2 manual pressure point then diesel engine will start automati-
cranking P.B, or by pressing on both (start from both bat- cally.
teries in parallel). • If the N/C contact of the deluge valve was opened, this
• Shutting down engine can only be done by pressing man- will cause the pump to start automatically exactly as if
ual stop Push Button. the pressure goes down to starting pressure.
• Failed to start alarm signal are not operational in this • In case of multiple pumps, it may be necessary to de-
mode, and all other alarm signals are operational. lay the starting of each engine to prevent simultane-
• Over speed alarm is functional in this mode, and will stop ous starting of all engines. Sequential starting can be
the pump directly and automatically and actuate alarm, adjusted by a programmable timer (1 – 99 seconds).
and controller will not start engine again unless operator User has to specify whether the pump is connected as
resets the over speed relay at diesel engine, and then single/parallel with other pumps, or if the pump is con-
resets the Over Speed Alarm by pressing reset PB of the nected in series with other pumps (programmable). In
controller. the first case (single or parallel), system will apply time
• Low oil pressure and high water temperature errors will delay before automatic start (by water pressure or
not stop the diesel engine, but only will give alarm, and deluge valve), but starting by remote start will not be
alarm will remain until operator resets it by pressing reset delayed. In the second case (series), system will apply
PB. time delay before automatic start (by water pressure
or deluge valve), and also before starting by remote
start, and this is to avoid dry running of pump (see ta-
ble 4).

TIME DELAY BEFORE STARTING THE FIRE PUMP

REASON OF STARTING SINGLE PUMP OR PARALLEL PUMPS SERIES PUMPS

Drop in pressure With delay With delay

Deluge valve With delay With delay

Remote start No delay With delay

www.naffco.com 9
• If remote start switch was momentarily actuated, troller (this option can be used in case of having a
the diesel engine will start directly and automatically, stand-by pump, where it is not desired both pumps
and it will not stop unless operator presses stop push to start automatically at the same time).
button on the panel’s door. In this mode (remote • Automatic starting for the diesel engine will be done
start mode) there will be no effect of the low oil pres- by automatic cranking from battery 1, and if failed
sure alarm, high water temperature alarm, and also will from battery 2, with certain cranking and rest
be no effect of deluge valve signal and low pressure period (period is programmable). Controller will try
signal. to crank engine up to six times, but if engine did
• Engine automatic start by pressure sensor and del- not start after these six attempts, “Failed To
uge valve can be disabled by pump lockout contact Start Alarm” will be activated, as shown in fig (2):
(external contact) which can be connected with con-

Figure (2)

• If remote start switch was momentarily actuated, troller (this option can be used in case of having a
the diesel engine will start directly and automatically, stand-by pump, where it is not desired both pumps
and it will not stop unless operator presses stop push to start automatically at the same time).
button on the panel’s door. In this mode (remote • Automatic starting for the diesel engine will be done
start mode) there will be no effect of the low oil pres- by automatic cranking from battery 1, and if failed
sure alarm, high water temperature alarm, and also will from battery 2, with certain cranking and rest
be no effect of deluge valve signal and low pressure period (period is programmable). Controller will try
signal. to crank engine up to six times, but if engine did
• Engine automatic start by pressure sensor and del- not start after these six attempts, “Failed To
uge valve can be disabled by pump lockout contact Start Alarm” will be activated, as shown in fig (2):
(external contact) which can be connected with con-

10 www.naffco.com
METHODS OF STOPPING THE FIRE PUMP

REASON OF STARTING AUTOMATIC STOP MANUAL STOP

YES - selectable
Drop in pressure With delay
(After running hold time)
YES - selectable
Deluge valve With delay
(After running hold time)

Remote start NO YES

Remote start NO YES

• If one of the batteries was dead or disconnected, the alarms was activated, and alarm will remain until op-
controller will automatically crank all six attempts from erator resets it by pressing reset PB.
the healthy battery and ignore the dead battery. • In this mode (auto), operator can’t start the diesel
• Two ways of shutdown are possible in this mode (opera- engine by the manual cranking push buttons.
tor have to select one of them by software): • Over speed alarm is functional in this mode, and will
stop the pump directly and automatically and actu-
1. Manual shutdown: After automatic start, engine can ate alarm, and controller will not start engine again
be stopped in this mode only by pressing manual
stop push button, but engine can’t be stopped if unless operator resets the over speed relay at
the pump was still on demand (pressure still low or diesel engine, and then resets the Over Speed
deluge valve still active), unless user put the switch on Alarm by pressing reset PB of the controller.
OFF position. • All alarm signals are operational in auto mode.
2. Automatic shutdown: After automatic start, controller
will keep engine running for a period varies from 1 to 120 • Automatic weekly test is only operational at auto
minutes (programmable). After that, if the pump was mode and can be enabled or disabled (operator
not any more on demand, then controller will auto- selection). If enabled, then user has to program the
matically shutdown the engine. If within this period, delay time before starting the test. Also to pro-
the pump became not on demand, operator can shut it gram the day, hour and minute where the weekly
down manually by pressing manual stop push button.
automatic test is desired to start. Test can be termi-
• When the engine is running because the pump be- nated by pressing Test ON/OFF push button.
ing on demand (due to low pressure or activation • Manual test is operational in auto mode only, and it
of deluge valve or remote start), it will not stop if there can be applied by pressing test ON/OFF push but-
was high water temperature alarm, or low oil pressure ton. Test can be terminated by pressing Test ON/
alarm, but if it was running and the reason of starting OFF push button again.
has gone then it will directly stop if any of these two

Compatibility with fuel solenoids engines and with


stopper solEnoids engines
NFY-DM1 controller can be connected with engines solenoid for some seconds (programmable), and
that can be stopped by stopper solenoid or by fuel by deactivating the fuel solenoid. After this time
solenoid, and it works as the following: delay, engine should be completely stopped. After
• In OFF mode, controller will directly stop the engine that controller will activate back the fuel solenoid to
by activating the stopper solenoid for some seconds keep engine ready for running again.
(programmable), and by deactivating the fuel sole- • In Automatic mode, controller will not activate any
noid. After this time delay, engine should be complete- solenoid if pump was not on demand, but when
ly stopped. pump becomes on demand (engine to run), con-
• In Manual mode, controller will be always activating troller will activate fuel solenoid to allow engine
fuel solenoid to keep engine ready for running. If the to crank and run. And after running, if engine has
engine was running in this mode and then manually got to stop, then controller will do the same stop-
stopped, then (same as OFF mode), controller will ping sequence as in OFF mode above.
directly stop the engine by activating the stopper

RATINGS

LINE VOLTAGE DC VOLTAGE ENCLOSURE SIZE


(VAC) (VDC) (MM)

220/110 12/24 900(H) x 600(W) x 300(D)

Figure (6)

www.naffco.com 11
UL LISTED JOCKEY PUMP CONTROLLER
MODEL NFY-JSD1 REDUCED VOLTAGE/
STAR – DELTA (OPEN TRANSITION)
MODEL NFY-JDO1 DIRECT ON LINE

NAFFCO Jockey Pump Controllers for fire pumps are recognized components are used in these panels to
listed by Underwriters Laboratories (UL file number guarantee the best possible reliability. Also high qual-
E309408), in accordance with UL508a (Standard for ity UL listed enclosures are used.
Industrial Control Panel), NFPA70 (National Electric
Code) and NEMA. The controller is completely wired, assembled and
tested at the factory before shipment, and ready for
Power ratings vary from 1.5 to 40 horsepower, 380 to immediate installation.
415 volts, 50 or 60 Hz. Only high quality UL listed or UL

STANDARD FEATURES
• Main disconnected switch with rotary handle, sized for
disconnecting motor horsepower and voltage.
• Motor Starter rated to motor’s horse power, with ther-
mal and short circuit protection.
• Rated motor contactors.
• Circuit breaker for protection of control circuit.
• Selector switch for Hand—Off—Automatic operation.
• Star—Delta starting timer. ( in Model NFY-JSD1 )
• Power ON/Healthy indicator/free contact.
• Pump Run indicator/free contact.
• Pump Trip indicator/free contact.
• Adjustable pressure switch.
• UL listed enclosure.

SEQUENCE OF OPERATION
This controller is working under three modes automatic
off and manual mode.

OFF (RESET) MODE


In this mode, the controller is considered to be off and
can’t start the Jockey pump.

AUTOMATIC START
In this mode, controller will start the Jockey pump
automatically and directly at low pressure detection by
the pressure switch, and will stop the pump automati-
cally and directly when the pressure goes up again.

MANUAL START
In this mode, controller will start the Jockey pump
directly, and will not stop until selector switch is
switched off or in Auto mode.

12 www.naffco.com
RATING

RATED SHORT CIRCUIT


POWER RATED VOLTAGE FREQUENCY ENCLOSED SIZE
CONTENT CURRENT
(HP) (VAC) (Hz) (mm)
(A) (kA)

1.5 380 - 415 50 or 60 3.3 5 500(H) x 400(W) x 250(D)

2 380 - 415 50 or 60 4.3 5 500(H) x 400(W) x 250(D)

3 380 - 415 50 or 60 6.1 5 500(H) x 400(W) x 250(D)

5 380 - 415 50 or 60 9.7 5 500(H) x 400(W) x 250(D)

7.5 380 - 415 50 or 60 14 5 500(H) x 400(W) x 250(D)

10 380 - 415 50 or 60 18 5 500(H) x 400(W) x 250(D)

15 380 - 415 50 or 60 27 5 500(H) x 400(W) x 250(D)

20 380 - 415 50 or 60 34 5 500(H) x 400(W) x 250(D)

25 380 - 415 50 or 60 44 5 600(H) x 500(W) x 250(D)

30 380 - 415 50 or 60 51 5 600(H) x 500(W) x 250(D)

40 380 - 415 50 or 60 66 5 600(H) x 500(W) x 250(D)

Table (7)

www.naffco.com 13
MANAGEMENT
SYSTEMS

ASSESSED TO ISO 9001:2008

QUALITY SYSTEM
NAFFCO FZCO is certified to ISO 9001 Quality system by UL DQS Inc, Loss Prevention Certification
Board UK & Bureau Veritas. Our manufacturing processes are based on a quality system that ensures
the use of raw material conforming to relevant International Standards. Our in process production is
monitored by work standards & quality plans conforming to relevant International Standards enabling
us to deliver quality products.

APPROVALS
NAFFCO has been maintaining ISO 9001 Quality Management system certified by UL, LPCB & BV.
Further we have achieved ISO14001 for Environmental Management & BS OHSAS 18001 for
occupational safety by UL management systems. We have also achieved product certifications from
UL, FM, LPCB, BSI, CE & SAI Global on wide range of products which include Fire Extinguishers, Fire
Hose Reels, Centrifugal Fire Pumps, Diesel Engine for driving Fire Pumps, Fire doors and Fire Fighting
Equipment. UL has authorized NAFFCO as service center for certifying signal and fire alarm equipment.

ENGINEERING CAPABILITIES
NAFFCO is backed by a team of professionals who are well qualified and specialized in their respective
field viz. - Design, Development, Production and Project Implementation. Our investment in applied
research and development program concentrates on innovations which meets customer needs.

PRODUCT RANGE

CAT.NO.NF/MBFPC/10/13

Your most reliable partner in supplying


state-of-the-art products and providing
high quality services based on
International Standards