Date: 03-May-2018
Action Plan/
S. Guide Existing
Parameter Possible Causes Consequences Additional
No Word Provisions
Provisions
Flow NO/LESS 1. Condensate I/V -Rate of filing of - Not required -Nil
in economiser T402 is less.
outlet closed or -Receiver level
throttled. increases.
2. LCV 608 in open -
condition.
3. Running
compressor trips
4. LCV 607 in close
condition.
5. Condensate inlet
I/V to T402
6.EFCV activated
7.T402 high
pressure
MORE 1. HT compressor - Filling rate 1.SOP: HT
running and of T402 - SRV is present. condensate
condensate I/V more. should not be
open. - T402 lined to T402
pressure 2. Pressure
Increases high/low alarm
to be provided
in CR
Pressure HIGH 1. Both LCV 607 - Pressure - TRV available
and LCV 608 in build up.
close condition.
2. Condensate inlet
I/V to T402 and LCV
608 closed.