Installation Manual
Rev. 1.1
April 2010
Release Info
ATRONIC OXYGEN™ Cabinet
Installation Manual
Rev. 1.1
Copyright Notice:
© 2010, ATRONIC. All rights reserved.
No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval
system, or translated into any human or computer language, in any form or by any means, electronic,
mechanical, magnetic, manual, or otherwise, or disclosed to third parties without the express written
permission obtained from a properly authorized official of ATRONIC.
DISCLAIMER
ATRONIC makes no representation or warranties, express or implied, with respect to this publication,
or any product of ATRONIC, including but not limited to warranties of merchantability or fitness for any
particular purpose. ATRONIC reserves the right to make changes, enhancements, revisions and altera-
tions of any kind to this publication or the product(s) it covers without obligation to notify any person,
institution or organization of such changes, enhancements, revisions and alterations.
TRADEMARKS
This document may contain trademarks of ATRONIC. All other brand and product names are trademarks
or registered trademarks of their respective companies.
2. Safety Instructions..................................................................................................... 7
2.1 Safety Instructions - Electrical.................................................................... 7
2.2 Safety Instructions - Mechanical............................................................... 8
2.3 Safety Instructions - Other........................................................................... 8
2.4 Environmental.................................................................................................. 8
3. Technical Data.............................................................................................................. 9
3.1 Specifications................................................................................................... 9
3.2 Dimensions.....................................................................................................10
3.3 Minimum Clearance.....................................................................................10
3.4 Footprint / Drill Pattern...............................................................................11
3.5 Ergonomics.....................................................................................................12
4. Machine Components............................................................................................13
4.1 Cabinet Closed...............................................................................................13
4.2 Main Door Opened.......................................................................................14
4.3 Belly Door Opened.......................................................................................15
4.4 Logic Box..........................................................................................................16
5. Machine Installation...............................................................................................18
5.1 Inspect the Machines..................................................................................19
5.2 Machine Mounting.......................................................................................20
5.3 Install Top Light or Topper.........................................................................21
5.4 Replace Shipping Locks..............................................................................22
5.5 Prepare Coin Acceptor (MC-62)...............................................................22
5.6 Check Cables and Connectors..................................................................22
5.7 Check Game Cards........................................................................................22
5.8 Install Operator Specific Components..................................................23
5.9 Connect to Floor Network.........................................................................24
5.9.1 CRYSTAL.net™.................................................................................24
5.9.2 CRYSTAL WEB™...............................................................................24
5.9.3 Non ATRONIC SMIBs.....................................................................24
5.9.4 System Connectors Pinout........................................................25
7. Technical Support.....................................................................................................28
Floor Personnel
Further we address floor personnel that is allowed to open the
machine‘s main door for maintenance purposes.
Please read the contained safety instructions before you open
the main door.
• Software Manual
Manual diversity™ Software (D.3.x.x STD)
• Operating Manual
Manual OXYGEN™ - Operating (D.3.x.x STD)
• Spare Parts
Manual OXYGEN™ - Parts Catalogue
If this manual did not came on this CD-ROM, please ask ATRONIC
Technical Service for a free copy of the latest revision.
* to gain access an active Gamebook account is necessary.
Use the specified fuses only. If the specified fuses easily blow
out, please consult ATRONIC Technical Services.
2.4 Environmental
Adhere to the environmental specifications stated in section
3. Technical Data (next page).
Weight: 97 kg (coin-less)
104 kg (coin-on)
Electrical Specification
Required Voltage: 100V to 240V AC
50Hz / 60Hz
Use earthed power outlet rated min. 8A / 115V, 4A / 230V.
Power Consumption
Idle Mode: 1,9A / 115V, 0,8A / 230V
Payout Mode: 2,4A / 115V, 1,2A / 230V
Max. Power: 450 Watt
(without internal power outlets)
Power Supply
Secondary Voltage: +24V / 5A; +12V / 17A;
- 12V / 0,5A; +5V / 20A;
+3.3V / 7A
3.2 Dimensions
1520 (mm)
1390
510 348
560 492
613 590
67 REAR OF CABINET
37
67,5
57
Ø 12 mm (4x)
228,5
271,5 (mm)
CABLE DROP
Ø 64mm
296,5
336,5
COIN DROP
Ø 80mm
DRILL PATTERN
OXYGEN™ CABINET
67
297
ATRONIC 302,5
STANDARD
BASE (720mm) 510
(720)*
Examples:
Height of available base is 24” / 60 cm --> use chair height 75 cm
Height of available base is 18” / 45 cm --> use chair height 60 cm
Height of available chair is 65 cm --> use 18” / 45 cm bases
Topper
Top Box
Coin Bowl
Top Box
Logic Box
Logic Box Lock
Card Slot Cover
Peripheral Board
Bill Acceptor
Coin In Bill In
/ Ticket Outlet
Figure shows logic box with the card slot cover removed
Peripheral Board
Connectors
LAN Port 1
LAN Port 2 (not used)
Power Supply
Connector
Review the list below and perform as needed. Explanations are Note: Depending on machine con-
located on the following pages and in additional manuals. figuration or jurisdictional require-
ments, additional tasks may have to
Inspect machines for transport damage. Any transport be carried out before the machine can
damage should be noted and witnessed by the freight be put into operation (e.g. acceptance
forwarder. The manufacturer accepts no responsibility for inspection, logic box sealing, etc.).
transport damage.
5.2 Machine Mounting
67 REAR OF CABINET
37
67,5
57
Ø 12 mm (4x)
228,5
271,5 (mm)
CABLE DROP
296,5
336,5
The drill pattern and the recommended minimum clear-
ance to the adjacent machines are provided in section 3.4 COIN DROP
Ø 80mm
DRILL PATTERN
67
297
ATRONIC 302,5
STANDARD
1. Open the main door and press the top box release up-
wards to open the top box door.
3. (a) Mount the top light and connect the top light signal
and the top light earthing cable.
(b) Mount the topper and connect the topper signal and
the topper earthing cable.
Make sure that the Platform Smart Card (1), the Game Smart
Card (2) and the Game CF Card (3) are seated correctly, prior to
initial power up. The cards may loose connection during trans-
portation.
(3)
(2)
The accounting system connection (SAS channel 1) is split into two connectors P220 and P221.
The connections for SAS channels 2 and 3 come as a D-Sub 9 male connector (serial connector).
1 NC 1 NC
2 COM 4 / RS232 RxD 2 COM 1 / RS232 RxD
3 COM 4 / RS232 TxD 3 COM 1 / RS232 TxD
4 +5V 4 +5V
5 Ground 5 Ground
6 NC 6 NC
7 +12V 7 +12V
8 NC 8 NC
9 NC 9 NC
1. Make sure that the power cable has not been damaged
during transport.
4. With the main door open, turn the power switch to the
“ON” position. The power up cycle will take some minutes,
because the machine checks the installed hardware, the
circuits boards firmware and security relevant circuits.
To enter the Service Menu turn the Audit Key with the
main door open.
5. Test Communication
Close the main door to switch to operation mode and test
the communication to the accounting system.
If technical assistance is required during normal business hours, please contact your local technical ser-
vices representative at one of the numbers below.
If technical assistance is required outside of normal business hours, please contact the ATRONIC Techni-
cal Hotline number below.