Sei sulla pagina 1di 1

8 7 6 5 4 3 2 1

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF


PROMETHEUS ENERGY COMPANY ANY REPRODUCTION IN PART OR IN WHOLE WITHOUT
THE WRITTEN PERMISSION OF PROMETHEUS ENERGY COMPANY IS PROHIBITED.

MODULE 30
REFRIGERATION
MODULE 30 COMPRESSOR
EXPANDER/COMPRESSOR SKID 1, TRAIN 1
SYSTEM SKID 2,TRAIN 1 PD-207
D PD-205 N Make Up D
PD-207A
PD-205A PD-207B
PD-207C

Vent / Boil Off Gas

MODULE 40
LIQUEFACTION
TRAIN 1
PD-206

MODULE 70
LNG STORAGE MODULE 70
MODULE 10 MODULE 20
PD-210 LNG PUMP &
PIPE LINE GAS METERING Reception & Purification
PD-210A TRUCK LOADING
4 Inch Carbon Steel SKID Pressure Control PD-202
C PD-201 PD-203 PD-210B C
PD-210C PD-211

3 X 15,600 Gallons 300 GPM

ZEUS GAS METERING SKID

Start Up Fuel MODULE 90


& Fuel Mixing
Makeup Fuel MODULE 90
Skid
FLARE SYSTEM MODULE 45
PD-212A
PD-213 LIQUEFACTION
TRAIN 2
A PD-216

NO FLOW EXPECTED TO FLARE

Module 90
NG GENERATOR 1

1,200 kW MODULE 35
MODULE 35 REFRIGERATION MODULE 60
EXPANDER COMPRESSOR NITROGEN
/ SYSTEM SKID 1, N Make Up GENERATOR
B COMPRESSOR TRAIN 2 B
PD-208
SYSTEM SKID 2, PD-217 PD-209
TRAIN 2 PD-217A PD-209A
PD-215 PD-217B PD-218
MODULE 50 PD-215A PD-217C
MODULE 90
NG GENERATOR 2 Power Distribution

1,200 kW 2,900 kW
4,1960 V
49-80V

MODULE 90
DIESEL
GENERATOR 3

500 kW

Power Plant - Flesan


UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
CAD GENERATED DRAWING

INTERPRET DIMENSIONS AND TOLERANCES PER


DO NOT MANUALLY UPDATE OKRA ENERGY
ASME Y14.5-1994
A A
TITLE
THIRD ANGLE PROJECTION
REVISIONS DO NOT SCALE DRAWING
NOTES: COLAN 30K LNG FACILITY & PLANT
1. RED LINES ARE FUEL GAS LINES. REV. DESCRIPTION DRAWN BY PROCESS MECH EIC MAN DATE BLOCK PROCESS FLOW DIAGRAM
2. LIGHT BLUE LINES ARE NITROGEN LINES FOR REFRIGERATION. A DRAFT DFG 10-MAR-18
DRAWN: DATE:
3. ORANGE LINES ARE VENT/BLOW-OFF GAS FROM THE FLASH VESSEL 40-2302. 0
THE PLANT WILL BE OPERATED FROM TO MINIMIZE GAS IN THIS STREAM. 1
DFG 10 MAR 18 SIZE DWG NO. REV.
4. DASHED GREY LINES ARE POWER LINES TO MODULE 50.
5. DURING NORMAL OPERATION GENERATOR #1 & #2 WILL BE RUNNING. CHECKED: DATE: D PID-XXXX-XXX-XXX 0
GENERATOR #3 WILL BE USED FOR START-UP & TRANSIENT LOADS ONLY. XXXX 00 XXX 00 SCALE SHEET
NTS 1 OF 1

8 7 6 5 4 3 2 1