New Freezer Ice Maker Fill Tube on French Door Models
R F120 8
05.30.12
CONDITION Water in the freezer ice maker tube may freeze. This may be caused or intensified by several condi-
tions, including low fresh food temperature setting, air leak around the air duct, or geometry of the fill
tube. Note that this condition is not related to that addressed in RF1102.
SOLUTION Replace freezer ice maker fill tube with kit 5303918600. This kit contains an improved fill tube. When
the new fill tube is installed, the connecting water line must be shortened by 2-2.5” to prevent kinking.
Foam pad needs to be placed on the tube only if similar pad was present on the original tube in the unit.
Also, investigate sealing of the air duct to the liner. Air leak in this area can contribute to freezing
of the fill tube. Use kit 5303918479 if needed to improve seal.
See RF1102 for additional instruction for select models equipped with single water valve.
CLAIM FILING This is NOT a policy service flash. Claims related to this repair should be filed normally and will ONLY
be covered during the warranty time period.