Sei sulla pagina 1di 49

ZXSDR B8200 L200

LTE Baseband Resource Unit


Maintenance Guide

Version 2.00

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION

Copyright © 2010 ZTE CORPORATION.

The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of
this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO-
RATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.

All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION
or of their respective owners.

This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are dis-
claimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-in-
fringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the
information contained herein.

ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject
matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,
the user of this document shall not acquire any license to the subject matter herein.

ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.

Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.

The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History

Revision No. Revision Date Revision Reason


R1.0 20100731 First Edition

Serial Number: SJ-20100705093724-004


Table of Contents

Preface.............................................................. I
Overview ...........................................................1
Maintenance Category..................................................... 1
Common Maintenance Methods ........................................ 1
Precautions.................................................................... 3
Maintenance Information ..................................5
Basic Maintenance Information Record .............................. 5
Version Information Collection Table.................................. 6
Routine Maintenance.........................................7
Routine Maintenance Information Definition ....................... 7
Routine Maintenance Items.............................................. 8
Routine Maintenance Schedule ......................................... 8
Daily Maintenance Items ................................................. 9
Monthly Maintenance Items ............................................. 9
Quarterly Maintenance Items ..........................................10
Semiannual Maintenance Items .......................................11
Annual Maintenance Items..............................................12
Maintenance Record Table............................... 15
Daily Maintenance Record ...............................................15
Monthly Maintenance Record ...........................................16
Quarterly Maintenance Record.........................................17
Semiannual Maintenance Record......................................19
Annual Maintenance Record ............................................19
Sudden Fault Handling Record .........................................20
Module Replacement Record............................................21
Cable Replacement Record..............................................22
Replacing Boards............................................. 23
Replacing CC Board .......................................................23
Replacing FS Board ........................................................24
Replacing BPL Board ......................................................25
Replacing SA Board........................................................26

Confidential and Proprietary Information of ZTE CORPORATION I


ZXSDR B8200 L200 Maintenance Guide

Replacing FAN Module ....................................................27


Replacing PM Module......................................................27
Replacing Cables ............................................. 29
Replacing S1/X2 Gigabit Ethernet Cable............................29
Replacing S1/X2 Electric Ethernet Cable ...........................31
Replacing SA Cable ........................................................31
Replacing Dry Contact Cable ...........................................34
Replacing GPS receiving Antenna Cable ............................36
Replacing NetNumen/LMT Cable ......................................36
Replacing Fiber Cable .....................................................37
Figures ............................................................ 39
Tables ............................................................. 41
Glossary .......................................................... 43

II Confidential and Proprietary Information of ZTE CORPORATION


Preface

Purpose At first, thank you for choosing ZXSDR B8200 L200 of ZTE Corpo-
ration!
ZXSDR B8200 L200 is a LTE FDD baseband resource unit. It is
based on LTE unified platform of SDR, adopts the MicroTCA archi-
tecture, and supports the 2U baseband unit.
ZXSDR B8200 L200 adopts distributed base station mode and thus
save operation/maintenance cost and equipment room expense.
When ZXSDR B8200 L200 working together with the correspond-
ing eRRU, they perform the whole function of eNodeB.
eNodeB implements such functions as radio resource manage-
ment, data stream IP header compression and encryption, attach
progress selection, user plane data routing, data scheduling and
transmission, and mobility management.
The purpose of this manual is to let the carrier master the system
maintenance of ZXSDR B8200 L200.
Intended This document is intended for:
Audience
� Maintenance engineer
� Operation engineer
Prerequisite Skill To use this document effectively, users should have a general un-
and Knowledge derstanding of wireless telecommunications technology. Familiar-
ity with LTE wireless network and its related components is helpful.
What is in This This manual contains the following chapters:
Manual

Chapter Summary

Chapter 1 Overview Describes the common maintenance


categories, maintenance principles, and
analysis methods, and precautions during
the routine maintenance

Chapter 2 Maintenance Describes the collection forms of the


Information general maintenance information and
version information

Chapter 3 Routine Describes the basic content of the routine


Maintenance maintenance of the equipment, and lists
the routine maintenance items of different
periods under different conditions

Chapter 4 Maintenance Describes the maintenance record for the


Record Table service personnel to refer to

Chapter 5 Replacing Describes how to replace the boards


Boards

Chapter 6 Replacing Describes how to replace the engineering


Cables cables

Confidential and Proprietary Information of ZTE CORPORATION I


ZXSDR B8200 L200 Maintenance Guide

This page is intentionally blank.

II Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1

Overview

Table of Contents
Maintenance Category......................................................... 1
Common Maintenance Methods ............................................ 1
Precautions........................................................................ 3

Maintenance Category
According to the daily maintenance, the maintenance can be clas-
sified into four categories that are routine maintenance, notice
processing, alarm processing, and common problem processing.
Routine Routine maintenance is the periodical maintenance. It is to check
Maintenance the equipment running state periodically. The problem detected
during the check should be handled in time. Thus, the hidden
problem can be discovered and prevented, and the problem can
be discovered and handled promptly.
Notice Processing Notice processing is to analyze various notices during the system
running, judge whether anomaly exists, and handle accordingly.
Alarm Processing Alarm processing is to analyze various alarms during the system
running, judge whether the system runs normally, and handle ac-
cordingly.
Common Problem Common problem processing is to analyze and handle the detected
Processing problem.

Common Maintenance
Methods
This topic describes the most common maintenance methods.
During the actual equipment maintenance, you need to combine
various methods.
Fault Symptom Generally, the wireless network equipment consists of several
Analysis equipment entities. The symptom varies with the fault that occurs
on different entity. When you discover a fault or receive a fault
report, you can analyze the fault symptom, judge the fault on
which equipment entity causes this symptom. Thus, you can
focus on checking the faulty equipment entity.

Confidential and Proprietary Information of ZTE CORPORATION 1


ZXSDR B8200 L200 Maintenance Guide

In the case of a sudden fault, it is especially important to analyze


the fault symptom. Only after analyzing the fault symptom care-
fully, you can locate the faulty equipment entity precisely. Thus,
you can avoid performing incorrect operation on the equipment
that runs normally, and shorten the time to rectify the fault.
Alarm and Log The eNodeB system can record errors that occur during the
Analysis equipment running and important running parameters. The errors
and important running parameters are mainly recorded in the log
record file (including the operation log and system log) and the
alarm database of NetNumen server.
The functions of alarm management are: checking the running
states of the eNodeB system, NetNumen server node and data-
base, and external power, collecting the fault and anomaly infor-
mation generated during the running, and presenting the infor-
mation in the form of text, figure, voice, and light. Thus, you can
learn the information in time and handle accordingly to ensure the
normal and reliable running of the eNodeB system.
In addition, the alarm information is recorded in the database for
later reference and analysis. You can check the operation log and
system log through the log management system. The log can be
filtered according to your filtering criteria and displayed in the time
sequence order or in the inverted time sequence order. Thus, you
can conveniently check useful log information.
The alarm and log analysis helps to analyze the cause of the fault
and detect the hidden problem of the system.
Signaling Tracing The signaling tracing tool provided by the system helps to analyze
Analysis and locate the fault effectively. According to the signaling trac-
ing, you can learn whether the signaling flow is correct, whether
all messages in the signaling flow are correct, and whether all pa-
rameters in the message are correct. Through the analysis, you
can find the cause of the fault.
Instrument Instrument and meter test is one of the most common methods
and Meter Test used to locate faults. Through the instrument and meter test, you
Analysis can test the system running indexes and environment indexes,
compare the test results with the indexes in the normal state, and
analyze the cause of the difference.
Comparison and Replace the part that may be faulty with a normal part. If the fault
Replacement is rectified after the replacement, the fault is located.
This method is simple and practical. In addition, you can com-
pare whether the states, parameter and log files, and parameter
settings of the same parts are the same. You can implement the
modification test to rectify the fault during the safe time.

Warning:
Perform this method during the safe time (00:00–04:00 in non-
holidays is recommended). Avoid the operation during the peak
service hours and holidays.

2 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 1 Overview

Precautions
During the daily maintenance, pay attention to the following pre-
cautions:
1. Ensure that the equipment room is of normal temperature,
clean, dirt-proof and moisture-proof. Prevent the rodent from
entering the equipment room.
2. Ensure that the primary power supply of the system is sta-
ble and reliable. Check the grounding and lightning protection
grounding of the system regularly. Especially before thunder-
storm season and after thunderstorm, check the lightning pro-
tection system and ensure that the facilities are normal.
3. Set up a sophisticated maintenance system to normalize the
daily work of the service personnel. Produce a detailed duty
log. Record the daily running status, version, data update, up-
grade, and problem handling of the system in details to help the
problem analysis and handling. Produce a hand-over record to
clarify the responsibility.
4. Prohibit playing games and surfing the Internet on the PC ter-
minal. Prohibit installing, running and copying any software
that is not related with the system on the PC terminal. Prohibit
misusing the PC terminal.
5. Set the NetNumen password according to the user levels, man-
age it strictly, change it regularly, and keep it open only to the
service personnel.
6. The service personnel should receive the induction training to
learn certain equipment and network knowledge. Perform the
maintenance operation according to the description in the re-
lated equipment manual. Wear the antistatic wrist strap be-
fore touching the equipment to prevent the accident due to
the man-made factor.
7. Do not blindly reset the equipment, load data or change data.
Especially do not change the EMS database data at random.
Back up the data before changing the data. After changing the
data, confirm that the equipment runs normally in a certain
period of time (generally a week) before deleting the backup
data. Record the change in time when changing the data.
8. Prepare the following common instruments and meters: flat-
head screwdriver, cross screwdriver, signaling analyzer, net-
work cable pliers, multimeter, AC power for maintenance, tele-
phone line, and network cable. Test the meters regularly to
ensure the accuracy.
9. Check the spare parts and accessories regularly to ensure that
they are in stock and complete. Prevent them from being af-
fected with damp and going mouldy. Store the spare parts and
accessories and the replaced parts and accessories separately,
and label them. Replenish the common spare parts and acces-
sories in time when they are used up.
10. Store the software and documentation that may be used during
the maintenance in the specified place. Thus, you can easily
obtain them when necessary.

Confidential and Proprietary Information of ZTE CORPORATION 3


ZXSDR B8200 L200 Maintenance Guide

11. Lighting in the equipment room should meet the maintenance


requirement. Repair the broken light in time to prevent the
lighting dead angle.
12. Handle the detected problem in time. In the case of the prob-
lem that cannot be handled, contact the local ZTE branch office.
13. Place the contact with the local ZTE branch office in an obvi-
ous place and inform all the service personnel to ensure timely
contact when necessary. Update the contact list regularly.

Danger:
Checking and adjusting the power should be performed by profes-
sionals. Otherwise, casualty and equipment failure may occur.

Warning:
Before changing and synchronizing data, obtain consent of the
person in charge. Otherwise, changing data at random may cause
catastrophic failure.

4 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 2

Maintenance Information

Table of Contents
Basic Maintenance Information Record .................................. 5
Version Information Collection Table...................................... 6

Basic Maintenance
Information Record
Table 1 lists the equipment information to be collected during the
ZXSDR B8200 L200 maintenance.

TABLE 1 BASIC MAINTENANCE INFORMATION RECORD

Basic Maintenance Information Record

ZXSDR North lati-


B8200 L200 tude
name

ZXSDR East longi-


B8200 L200 tude
type

ZXSDR Altitude
B8200 L200
No.

ZXSDR
B8200 L200
ID (OMC
configura-
tion)

City/County Telephone of
the equip-
ment room

Position of
the equip-
ment room

Adopted
daisy chain
mode (de-
scribe the
link struc-
ture)

Confidential and Proprietary Information of ZTE CORPORATION 5


ZXSDR B8200 L200 Maintenance Guide

Version Information
Collection Table
Collect and record the ZXSDR B8200 L200 version information to
help the ZXSDR B8200 L200 maintenance. Table 2 lists the ZXSDR
B8200 L200 version information to be collected.

TABLE 2 ZXSDR B8200 L200 VERSION INFORMATION

Module Version

CC version

BPL version

SA version

FA version

PM version

Remarks:

6 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3

Routine Maintenance

Table of Contents
Routine Maintenance Information Definition ........................... 7
Routine Maintenance Items.................................................. 8
Routine Maintenance Schedule ............................................. 8
Daily Maintenance Items ..................................................... 9
Monthly Maintenance Items ................................................. 9
Quarterly Maintenance Items ..............................................10
Semiannual Maintenance Items ...........................................11
Annual Maintenance Items..................................................12

Routine Maintenance
Information Definition
Routine maintenance means to implement preventive check on the
equipment regularly. This guarantees the stable running of the
equipment for a long period.
Routine maintenance mainly includes the following two aspects:
� Check and test the running status, functions, major perfor-
mance indicators, and hardware completeness of the ZXSDR
B8200 L200 equipment regularly and in a planned way. The
check and test must be done according to the technical speci-
fications and technical requirements of the equipment parts.
� Regular check and cleaning. Check the hardware of the ZXSDR
B8200 L200 and its attachment equipment. If any problem is
detected, make adjustment, correction, or replacement imme-
diately to ensure the hardware completeness. Regularly main-
tain and clean the part that is highly dustproof or vulnerable.
Regularly clean the major parts of other peripheral equipment
to ensure the normal running.
Make reasonable periodical table for the periodical check and main-
tenance work according to the actual condition, and conform with
the specified maintenance period to implement the work.

Confidential and Proprietary Information of ZTE CORPORATION 7


ZXSDR B8200 L200 Maintenance Guide

Note:
The ZXSDR B8200 L200 is an unattended equipment. Its realtime
running status can be observed on the OMC side. The OMC service
personnel are responsible to implement the daily maintenance of
the ZXSDR B8200 L200.

Routine Maintenance Items


Routine maintenance consists of various regular check and main-
tenance tasks. This guarantees that the equipment runs in the
best state to meet the service requirement of the subscribers and
prevents potential failure.
Routine maintenance of the equipment includes but is not limited
to the following items:
1. Checking the working environment of the equipment
2. Collecting performance statistics of the equipment
3. Maintaining the alarm system
4. Backing up data
5. Checking spare parts
6. Maintaining the board
7. Checking the log
8. Checking the grounding and lightening protection systems
9. Checking the running status of the power module
10. Checking the antenna feeder system
11. Preparing for holidays

Routine Maintenance
Schedule
According to different maintenance periods, routine maintenance
can be categorized into periodical maintenance and casual main-
tenance.
The periods of periodical maintenance are daily, monthly, quar-
terly, semiannual, and annual. The items of casual maintenance
are determined according to the actual condition of the faulty
equipment.
The specific items, operation guide, and reference standard of the
periodical maintenance vary with the period. The actual condition

8 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 Routine Maintenance

and service of each carrier vary. Therefore, determine a proper


period of routine maintenance according to the actual condition.

Daily Maintenance Items


Table 3 lists the daily maintenance items of the ZXSDR B8200
L200.

TABLE 3 DAILY MAINTENANCE ITEMS

Maintenance Sub-item Description


Item

Checking the Alarm processing Check all alarms from the time
alarm and of last check to the current
notice time on the EMS terminal and
categorize and process the
alarms according to the alarm
level

Notice processing Analyze the notice that appears


frequently. Ignore the common
notice

Troubleshoot- Handling common Handle the common troubles in


ing troubles the alarms such as transmission
failure and board failure

Handling the Analyze and handle the network


subscriber quality problem reported by
complaints subscribers

Monthly Maintenance Items


Table 4 lists the monthly maintenance items of the ZXSDR B8200
L200.

TABLE 4 MONTHLY MAINTENANCE ITEMS

Mainte- Description
nance Item

Checking the Check the temperature and humidity of the equipment


temperature and equipment room. Check the temperature in the
and humidity alarm management system of the OMC. Measure the
humidity with a hygrometer

Checking the Check the running status of the module in the alarm
running sta- management system of the OMC. As for the faulty mod-
tus of the ule, check through the diagnostic test system
module

Confidential and Proprietary Information of ZTE CORPORATION 9


ZXSDR B8200 L200 Maintenance Guide

Mainte- Description
nance Item

Checking the Implement the test by using a terminal on the ZXSDR


voice serv- B8200 L200 site. Observe the service. Survey the serv-
ice and data ice condition of each sector. Check whether disconnec-
service tion, interruption, and throughput abnormality exist

Checking the Check the power supply of the ZXSDR B8200 L200
running sta-
tus of the
power mod-
ule

Checking the
grounding
and lighten- Check the working status of the grounding and lighten-
ing protec- ing protection systems and check whether connections
tion system are reliable

Other remarks:

Quarterly Maintenance Items


Table 5 lists the quarterly maintenance items of the ZXSDR B8200
L200.

TABLE 5 QUARTERLY MAINTENANCE ITEMS

Maintenance Item Description

Checking the running status of Check the running status of the mod-
the ZXSDR B8200 L200 mod- ule in the alarm management system
ule of the OMC. As for the faulty module,
check through the diagnostic test sys-
tem

Checking the voice service and Implement the test by using a termi-
data service nal on the ZXSDR B8200 L200 site.
Observe the service. Survey the serv-
ice condition of each sector. Check
whether disconnection, interruption,
and throughput abnormality exist

Checking the running status of Check the power voltage of the ZXSDR
the power module B8200 L200

Checking the grounding and Check the working status of the


lightening protection systems grounding and lightening protection
systems and check whether connec-
tions are reliable

10 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 Routine Maintenance

Maintenance Item Description

Checking the standing wave Check whether SWR alarm is gener-


ratio (SWR) of the antenna ated. Measure the SWR of each an-
feeder tenna feeder. Pay special attention
to connecting the feeder reliably after
measuring the SWR

Measuring the ground resist- Measure the ground resistance with


ance and checking the ground- a ground resistance tester, and check
ing wire whether the resistance is qualified

Check whether the connector of each


grounding wire is in loose contact or
aged

Checking the connector of the Check whether the surface is in good


antenna feeder and the water condition. Unfold the insulating tape
resistance, and grounding con- when necessary. Pay attention to fold-
nection of the lightening pro- ing the insulating tape again after the
tection grounding kit check

Checking whether the antenna Check whether the antenna is beyond


is firm and checking the pitch the scope requirement of the network
angle and directional angle of plan due to the wind. Use the span-
the directional antenna ner and angle meter to adjust the an-
tenna. Be careful not to overexert on
screwing the nut by the spanner

Checking the lightening protec- Check whether the connection of the


tion lightening protection ground wire is
reliable, and check the rust resistance
of the connection

Other remarks:

Semiannual Maintenance
Items
Table 6 lists the semiannual maintenance items of the ZXSDR
B8200 L200.

Confidential and Proprietary Information of ZTE CORPORATION 11


ZXSDR B8200 L200 Maintenance Guide

TABLE 6 SEMIANNUAL MAINTENANCE ITEMS

Maintenance Item Description Remarks

Checking the Check the working Implement an


lightening protection ground of the additional check
grounding equipment. Check before and after
the protective ground nature disaster such
of the equipment as typhoon and
room. Check the thunderstorm
grounding trunk line
of the eNodeB. Check
the construction
lightening protection
ground. Test all the
ground resistances

Annual Maintenance Items


Table 7 lists the annual maintenance items of the ZXSDR B8200
L200.

TABLE 7 ANNUAL MAINTENANCE ITEMS

Maintenance Item Description

Checking the cleanness and Clean the surface of the cabinet with a
airtightness of the cabinet vacuum cleaner or towel. Pay special
attention not to touch the switch or
power by mistake. After opening the
cabinet, check whether there is water
in the cabinet and whether the upper
and lower covers of the cabinet are
airtight

Checking the temperature and Check the temperature in the alarm


humidity management system of the OMC.
Measure the humidity with a hygrom-
eter

Checking the running status of Check the running status of the mod-
the module ule in the alarm management system
of the OMC. As for the faulty module,
check through the diagnostic test sys-
tem

Checking the voice service and Implement the test by using a termi-
data service nal on the ZXSDR B8200 L200 site.
Observe the service. Survey the serv-
ice condition of each sector. Check
whether disconnection, interruption,
and throughput abnormality exist

Checking the running status of Check the power voltage of the ZXSDR
the power module B8200 L200

12 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 3 Routine Maintenance

Maintenance Item Description

Checking the grounding and Check the working status of the


lightening protection systems grounding and lightening protection
systems. Check whether the con-
nection is reliable and whether the
discharge arrester is burnt

Checking the SWR of the an- Check whether SWR alarm is gener-
tenna feeder ated. Measure the SWR of each an-
tenna feeder. Pay special attention to
connecting the antenna feeder reliably
after measuring the SWR

Measuring the ground resist- Measure the ground resistance with


ance and checking the ground- a ground resistance tester, and check
ing wire whether the resistance is qualified

Check whether the connector of each


ground wire is in loose contact or aged

Checking the connector of the Check whether the surface is in good


antenna feeder and the water condition. Unfold the insulating tape
resistance, and grounding con- when necessary. Pay attention to fold-
nection of the lightening pro- ing the insulating tape again after the
tection grounding kit check

Checking whether the antenna Check whether the antenna is beyond


is firm and checking the pitch the scope requirement of the network
angle and directional angle of plan due to the wind. Use the span-
the directional antenna ner and angle meter to adjust the an-
tenna. Be careful not to overexert on
screwing the nut by the spanner

Checking the lightening protec- Check whether the connection of the


tion lightening protection ground wire is
reliable, and check the rust resistance
of the connection point

Other remarks:

Confidential and Proprietary Information of ZTE CORPORATION 13


ZXSDR B8200 L200 Maintenance Guide

This page is intentionally blank.

14 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4

Maintenance Record
Table

Table of Contents
Daily Maintenance Record ...................................................15
Monthly Maintenance Record ...............................................16
Quarterly Maintenance Record.............................................17
Semiannual Maintenance Record..........................................19
Annual Maintenance Record ................................................19
Sudden Fault Handling Record .............................................20
Module Replacement Record ...............................................21
Cable Replacement Record..................................................22

Daily Maintenance Record


Date: Year Month Day

Time on duty: From to Handover from: Handover to:

Current alarm processing record of the eNodeB

eNodeB No. Alarm content Alarm Alarm Remarks


start end time
time

Anomaly history alarm record of the eNodeB

eNodeB No. Anomaly alarm content and processing Remarks

Confidential and Proprietary Information of ZTE CORPORATION 15


ZXSDR B8200 L200 Maintenance Guide

Anomaly history notice record of the eNodeB

eNodeB No. Anomaly notice content and processing Remarks

Subscriber complaint processing

eNodeB No. Complaint content and processing Remarks

Handover content:

Verified by team leader:

Monthly Maintenance
Record
Time: Year Month Day...Hour Service personnel:

Check Item Condition Handling Remarks


Description Method

Are the position


parameters of
the eNodeB the
same as the
actual position
parameters?

Is the
equipment rack
clean?

Is the cable rack


firm?

Are the fiber


connectors
and other
connectors in
good contact?

Are the
indicator
lights of the
equipment in
the normal
state?

16 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 Maintenance Record Table

Check the
temperature
and humidity

Check the voice


service and
data service

Check the
grounding
and lightening
protection
systems

Check the Are the spare □ Yes □ No


spare parts and parts and
accessories accessories in
stock and in
good condition?

Verified by team leader:

Quarterly Maintenance
Record
ZXSDR B8200 L200 Time: Year Month Day
Name:

Service personnel:

Maintenance Item Condition Remarks

Is the ZXSDR B8200 □ Yes □ No


L200 module running
normally?

Is the data service □ Yes □ No


running normally?

Is the power running □ Yes □ No


normally?

Are the grounding and □ Yes □ No


lightening protection
systems normal?

Are the ground □ Yes □ No


resistance and
grounding wire
normal?

Confidential and Proprietary Information of ZTE CORPORATION 17


ZXSDR B8200 L200 Maintenance Guide

Are the connector □ Yes □ No


of the antenna
feeder and the
water resistance and
grounding connection
of the lightening
protection grounding
kit normal?

Is the dustproof □ Yes □ No


assembly of the fan
module cleaned?

Fault description and


troubleshooting:

Outstanding issues:

Verified by team
leader:

18 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 Maintenance Record Table

Semiannual Maintenance
Record
Time: Year Month Service personnel:
Day...Hour

Check Item Check Result Remarks

Is the working ground of □ Yes □ No


the equipment connected
reliably?

Is the protection ground □ Yes □ No


of the equipment room
connected reliably?

Is the grounding trunk □ Yes □ No


line of the eNodeB
reliable?

Measure the ground Value:


resistance

Annual Maintenance Record


Equipment name: Time: Year Month Day

Service personnel:

Condition
Check Item Description Remarks

Is the cabinet clean? □ Yes □ No

Are the temperature and hu-


midity normal? □ Yes □ No

Is the module running nor-


mally? □ Yes □ No

Are the voice service and data


service normal? □ Yes □ No

Is the power running normally? □ Yes □ No

Are the grounding and lighten-


ing protection systems normal? □ Yes □ No

Is the SWR of the antenna


feeder normal? □ Yes □ No

Are the value of the ground


resistance and grounding wire
normal? □ Yes □ No

Are the connector of the an-


tenna feeder and the water
resistance and grounding con- □ Yes □ No

Confidential and Proprietary Information of ZTE CORPORATION 19


ZXSDR B8200 L200 Maintenance Guide

Equipment name: Time: Year Month Day


nection of the lightening pro-
tection grounding kit normal?

Is the antenna firm and are the


pitch angle and directional an-
gle of the directional antenna
normal? □ Yes □ No

Is the lightening protection


normal? □ Yes □ No

Fault description and troubleshooting:

Outstanding issues:

Verified by team leader:

Sudden Fault Handling


Record
Unexpected fault handling record

Site name: Handling person:

Occurrence time: Handling time:

Fault source: □ Customer complaint □ Alarm system □ Found during


routine maintenance □ Others

Fault type:

Fault description:

Handling method:

20 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 4 Maintenance Record Table

Result:

Comment of the person in charge:

Module Replacement
Record
Module replacement record

eNodeB No.: Service personnel:

Module Module Fault Re- SN of SN of the


Name Slot Time place- the Faulty Replacement
ment Module Module
Time

Confidential and Proprietary Information of ZTE CORPORATION 21


ZXSDR B8200 L200 Maintenance Guide

Cable Replacement Record


Cable replacement record

eNodeB No.: Service personnel:

Cable Cable Fault Re- SN of the SN of the


Name Connec- Time place- Faulty Cable Replacement
tion Po- ment Cable
sition Time

22 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5

Replacing Boards

Table of Contents
Replacing CC Board ...........................................................23
Replacing FS Board ............................................................24
Replacing BPL Board ..........................................................25
Replacing SA Board............................................................26
Replacing FAN Module ........................................................27
Replacing PM Module..........................................................27

Replacing CC Board
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old modules are the same.
Context Replacing the control and clock module (CC) may have the follow-
ing impacts on the system:
� Two CCs (active/standby) configured for the system
If the board to be replaced is in the active state, remove the
active board directly and the standby board switches over au-
tomatically. You can also switch the board to the standby board
before the replacement. The replacement process does not af-
fect the system and services.
� One CC configured for the system
The system is paralyzed during the board replacement process.
Pay attention to the following precautions when replacing the CC:
� When replacing the CC, pay attention to the CC version and
record it in time to prevent the mismatch or incompatibility of
the module with the system.
� Conform with the operation procedure strictly when replacing
the CC. This prevents great impact on the system running due
to incorrect operation.
� Test and verify the functions of the new module or system in
time after the replacement, to ensure the replacement success.
� When removing or inserting the fiber, do not contaminate the
fibre optic splice.
� Ensure that the module is in good contact with the slot when
inserting the module. Otherwise, electrical interference may

Confidential and Proprietary Information of ZTE CORPORATION 23


ZXSDR B8200 L200 Maintenance Guide

occur during the equipment running or the module may be


damaged.
� When taking the module, wear standard antistatic wrist strap
or antistatic gloves. The grounding end of the antistatic wrist
strap should be grounded properly.
Steps 1. Remove the module.
i. Open the lock and pull out the tact switch (namely, the
handle) of the module for two sections.
ii. Pull out the module along the guide rails.
2. Insert the module.
i. Insert the module along the guide rails of the subrack.
ii. Hold the tact switch on the left of the module and push the
module in. Ensure that the tact switch is in good contact
with the lock point of the subrack.

Note:
In the case that the IP address of the eNodeB is obtained in
the DHCP mode automatically, you need to configure the IP
address on the DHCP server after inserting the new module.
You need to ensure that the IP address corresponding to the
electronic barcode of the new CC is the same as the IP address
corresponding to the electronic barcode of the old CC. For re-
lated operations, contact ZTE techical support.

END OF STEPS

Replacing FS Board
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old modules are the same.
Context Replacing the FS board affects the system performance. The sys-
tem in certain coverage area is paralyzed.
Pay attention to the following precautions when replacing the FS:
� When replacing the FS, pay attention to the FS version and
record it in time to prevent the mismatch or incompatibility of
the module with the system.
� Conform with the operation procedure strictly when replacing
the FS. This prevents great impact on the system running due
to incorrect operation.
� Test and verify the functions of the new module or system in
time after the replacement, to ensure the replacement success.
� Ensure that the module is in good contact with the slot when
inserting the module. Otherwise, electrical interference may

24 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 Replacing Boards

occur during the equipment running or the module may be


damaged.
� When taking the module, wear standard antistatic wrist strap
or antistatic gloves. The grounding end of the antistatic wrist
strap should be grounded properly.
Steps 1. Remove the module.
i. Open the lock and pull out the tact switch (namely, the
handle) of the module for two sections.
ii. Pull out the module along the guide rails.
2. Insert the module.
i. Insert the module along the guide rails of the subrack.
ii. Hold the tact switch on the left of the module, and push the
module in. Ensure that the tact switch is in good contact
with the lock point of the subrack.
END OF STEPS

Replacing BPL Board


Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old modules are the same.
Context Replacing the BPL board affects the system performance. The sys-
tem in certain coverage area is paralyzed.
Pay attention to the following precautions when replacing the BPL:
� When replacing the BPL, pay attention to the BPL version and
record it in time to prevent the mismatch or incompatibility of
the module with the system.
� Conform with the operation procedure strictly when replacing
the BPL. This prevents great impact on the system running due
to incorrect operation.
� Test and verify the functions of the new module or system in
time after the replacement, to ensure the replacement success.
� When replacing the BPL, do not contaminate fiber connector if
you need to remove or insert the fiber.
� Ensure that the module is in good contact with the slot when
inserting the module. Otherwise, electrical interference may
occur during the equipment running or the module may be
damaged.
� When taking the module, wear standard antistatic wrist strap
or antistatic gloves. The grounding end of the antistatic wrist
strap should be grounded properly.
Steps 1. Remove the module.
i. Open the lock and pull out the tact switch (namely, the
handle) of the module for two sections.
ii. Pull out the module along the guide rails.

Confidential and Proprietary Information of ZTE CORPORATION 25


ZXSDR B8200 L200 Maintenance Guide

2. Insert the module.


i. Insert the module along the guide rails of the subrack.
ii. Hold the tact switch on the left of the module, and push the
module in. Ensure that the tact switch is in good contact
with the lock point of the subrack.
END OF STEPS

Replacing SA Board
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old modules are the same.
Context Replacing the site alarm module (SA) may have the following im-
pacts on the system:
� The system environment monitoring is terminated.
� The system cannot implement the function of fan speed ad-
justment.
Pay attention to the following precautions when replacing the SA:
� When replacing the SA, pay attention to the SA version and
record it in time to prevent the mismatch or incompatibility of
the module with the system.
� Conform with the operation procedure strictly when replacing
the SA. This prevents great impact on the system running due
to incorrect operation.
� Test and verify the functions of the new module or system in
time after the replacement, to ensure the replacement success.
� Ensure that the module is in good contact with the slot when
inserting the module. Otherwise, electrical interference may
occur during the equipment running or the module may be
damaged.
� When taking the module, wear standard antistatic wrist strap
or antistatic gloves. The grounding end of the antistatic wrist
strap should be grounded properly.
Steps 1. Remove the module.
i. Open the lock and pull out the tact switch (namely, the
handle) of the module for two sections.
ii. Pull out the module along the guide rails.
2. Insert the module.
i. Insert the module along the guide rails of the subrack.
ii. Hold the tact switch on the left of the module, and push the
module in. Ensure that the tact switch is in good contact
with the lock point of the subrack.
END OF STEPS

26 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 5 Replacing Boards

Replacing FAN Module


Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old modules are the same.
Context Replacing the fan module (FA) may have the following impacts on
the system:
� If the replacement takes a short time, the system does not
reach the over-temperature protection state. In this case, the
system and service are not affected.
� If the replacement takes a long time, the local temperature
is very high. In this case, the system enters the automatic
protection (such as automatic poweroff) state.
Steps 1. Remove the module.
Hold the handle of the FA and pull the FA out.
2. Insert the module.
Insert the module along the upper and lower guide rails. En-
sure that the clip on the fan subrack clamps the dustproof
assembly tightly. The sound of the locker indicates that the
fan subrack and the dustproof assembly are installed and fixed
firmly.
END OF STEPS

Replacing PM Module
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old modules are the same.
Context Replacing the power module (PM) may have the following impacts
on the system:
� Two PMs (load sharing): When you replace one of the PMs, the
boards supported by the PM are powered off. (The order in
which the boards are inserted into the shelf affects the loading
of the PMs.)
� One PM: When you replace the PM, the whole system is pow-
ered off.
Pay attention to the following precautions when replacing the PM:
� Conform with the operation procedure strictly when replacing
the PM. This prevents great impact on the system running due
to incorrect operation.
� Test and verify the functions of the new module or system in
time after the replacement to ensure the replacement success.
� Ensure that the module is in good contact with the slot when
inserting the module. Otherwise, electrical interference may
occur during the equipment running or the module may be
damaged.

Confidential and Proprietary Information of ZTE CORPORATION 27


ZXSDR B8200 L200 Maintenance Guide

� When taking the module, wear standard antistatic wrist strap


or antistatic gloves. The grounding end of the antistatic wrist
strap should be grounded properly.
Steps 1. Remove the module.
i. Open the lock and pull out the handle of the module.
ii. Pull out the module along the guide rails.
2. Insert the module.
i. Insert the module along the guide rails of the subrack.
ii. Hold the tact switch on the left of the module, and push the
module in. Ensure that the tact switch is in good contact
with the lock point of the subrack.
END OF STEPS

28 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6

Replacing Cables

Table of Contents
Replacing S1/X2 Gigabit Ethernet Cable................................29
Replacing S1/X2 Electric Ethernet Cable ...............................31
Replacing SA Cable ............................................................31
Replacing Dry Contact Cable ...............................................34
Replacing GPS receiving Antenna Cable ................................36
Replacing NetNumen/LMT Cable ..........................................36
Replacing Fiber Cable .........................................................37

Replacing S1/X2 Gigabit


Ethernet Cable
Context The GE communications fiber of the S1/X2 interface is the infor-
mation transmission media between the ZXSDR B8200 L200 and
other eNodeB/core network. During the fiber replacement, the
communications between the ZXSDR B8200 L200 and other eN-
odeB/core network is temporarily interrupted.

Caution:
When replacing the fiber, pay attention to the following precautions
:
� Do not break the protection layer of the fiber during the oper-
ation.
� Do not contaminate the fiber connector.
� Do not overexert on pulling out the old fiber or binding the new
fiber.
� Curve the turning point of the new fiber.

Steps 1. Confirm the type of the new fiber.


Before replacing the fiber, ensure that the types of the new
fiber and the old fiber to be replaced are the same.
2. Paste temporary labels on the new fiber.
Paste temporary labels at two ends of the new fiber to form
a matching relation. Differentiate the fibers by labels if more
than one fiber need to be replaced.

Confidential and Proprietary Information of ZTE CORPORATION 29


ZXSDR B8200 L200 Maintenance Guide

3. Lay the new fiber.


The position and cabling mode of the new fiber must be the
same as that of the old fiber to be replaced.
4. Disconnect one connector of the old fiber and connect the con-
nector of the new fiber.

Caution:
� Remove one connector of the old fiber to be replaced, and
cover the optical interface with the protective cap to pre-
vent it being contaminated.
� Insert the connector of the new fiber and ensure that the
connector is clamped firmly.

5. Disconnect the other connector of the old fiber and connect the
connector of the new fiber.
Find the connector at the other end of the old fiber according
to the number of the old fiber and remove the connector. Find
the connector at the other end of the new fiber according to
the temporary labels of the new fiber and insert the connector.

Caution:
� Remove one connector of the old fiber to be replaced, and
cover the optical interface with the protective cap to pre-
vent it being contaminated.
� Insert the connector of the new fiber and ensure that the
connector is clamped firmly.

6. Check the fiber replacement result.


Check whether the board related with the replacement fiber
works normally and whether the related alarms are generated
in the alarm management system.
7. Bind the new fiber.
Cut off the cable strap, remove the replaced old fiber, and then
lay the new fiber. When binding the fiber, conform with the
technique requirement of the equipment and fiber binding.
8. Paste the engineering labels on the fiber.
Remove the temporary labels and paste the engineering labels
on the new fiber. The contents in the labels of the new fiber
should be the same as that of the old fiber.
9. After the replacement, tidy the site and dispose the replaced
old Ethernet cable properly.
END OF STEPS

30 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 Replacing Cables

Replacing S1/X2 Electric


Ethernet Cable
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old Ethernet cables are
the same.
Context The electrical Ethernet communications cable of the S1/X2 inter-
face is the information transmission media between the ZXSDR
B8200 L200 and other eNodeB/core network. During the cable re-
placement, the communications between the ZXSDR B8200 L200
and other eNodeB/core network is temporarily interrupted.
Steps 1. Remove the faulty cable.
Pinch the turnup of the cable connector and pull out the cable.
2. Lay the new Ethernet cable and bind the cable.
Cut off the cable strap, remove the replaced old Ethernet cable,
and then lay the new Ethernet cable. When binding the cable,
conform with the technique requirement of the cable binding
of the equipment.
3. Install the Ethernet cable. Insert the connector into the cable
interface according to the shape of the cable interface.
4. Check the Ethernet cable replacement result.
Check whether the board related with the replacement Ether-
net cable works normally and whether the related alarms are
generated in the alarm management system.
5. Paste the engineering labels on the Ethernet cable.
Paste the engineering labels on the Ethernet cable. The con-
tents in the labels of the new Ethernet cable should be the
same as that of the old Ethernet cable.
6. After the replacement, tidy the site and dispose the replaced
old Ethernet cable properly.
END OF STEPS

Replacing SA Cable
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old RS232/RS485 moni-
toring cables are the same.
Context The RS232/RS485 monitoring cable is used to connect the external
monitoring equipment.Figure 1 shows the appearance of the cable.

Confidential and Proprietary Information of ZTE CORPORATION 31


ZXSDR B8200 L200 Maintenance Guide

FIGURE 1 RS232/RS485 MONITORING CABLE

The connector at end A is DB9 (M). End A is connected to the DB9


(end B2) of the SA panel cable.Figure 2 shows the appearance of
the SA panel cable.

FIGURE 2 APPEARANCE OF THE SA PANEL CABLE

Steps 1. Ensure that the types of the new and old RS232/RS485 moni-
toring cables are the same.
Before the replacement, ensure that the appearances of the
new and old cables are the same. In addition, ensure that the
codes of the new and old cables are the same.
2. Make the joint of the new cable.
Table 8 lists the signal descriptions of the RS232/RS485 mon-
itoring cable.

32 Confidential and Proprietary Information of ZTE CORPORATION


TABLE 8 SIGNAL DESCRIPTIONS OF THE RS232/RS485 MONITORING CABLE

Signal GNDD RS485_TX+ RS485_TX- GNDD RS485_ RS485_RX- RS232_ RS232_TXD GNDD
Definition RX+ RXD

Pins at end 1 6 7 4 8 9 2 3 5
A

Cable 1 White (White Blue) Green (White Orange)

Pins at end / /
B1

Cable 2 Blue Orange White/wh-


ite
Confidential and Proprietary Information of ZTE CORPORATION

Pins at end /
B2

– () indicates a twisted pair.


– 1 and 4 are a (white and green) twisted pair.
– Pin2 is the blue core of the (white and blue) twisted pair. Pin3 is the orange core of the (white and orange) twisted pair. Pin5 is connected to the
white cores of the (white and blue) and (white and orange) twisted pairs.

Chapter 6 Replacing Cables


33
ZXSDR B8200 L200 Maintenance Guide

3. Remove the old cable.


i. Cut off the cable strap.
ii. Disconnect the connector at end A of the old cable.
iii. Remove the old cable.
4. Lay the new RS232/RS485 monitoring cable.
i. Lay the new cable according to the cabling direction and
line order of the old cable. When laying the cable, conform
with the technique requirement of the cable binding of the
equipment.
ii. Insert end A of the new cable into interface B2 of the SA
data cable and fix the new cable.
5. Check the cable replacement result.
Check whether the board related with the replacement cable
works normally and whether the related alarms are generated
in the alarm management system.
6. After the replacement, tidy the site.
Dispose the replaced old cable properly, and tidy the site.
END OF STEPS

Replacing Dry Contact Cable


Prerequisites � Wear the antistatic wrist strap.
� Complete installing the SA board and its panel cable.
� Ensure that the types of the new and old dry contact input/out-
put cables are the same.
Context The input dry contact cable is used to import the dry contact signal
of the peripheral equipment.Figure 3 shows the appearance of the
cable.

FIGURE 3 INPUT/OUTPUT DRY-CONTACT INTERFACE CABLE

End A is connected to the DB25 plug (end B3) of the SA panel


cable (supporting four interfaces).Figure 4 shows the appearance
of the SA panel cable.

34 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 Replacing Cables

FIGURE 4 APPEARANCE OF THE SA PANEL CABLE

Steps 1. Label the new cable.


Put the same labels on the new cable as the labels on the old
cable according to the terminals and line order.
2. Connect end B of the new cable.
i. Disconnect one connector of end B of the old cable, and
connect the cable of the same line order and color at end
B of the new cable.
ii. Repeat the preceding procedure. Disconnect a connector of
an old cable and connect a connector of a new cable until
all the connectors of the new cables are connected.
3. Remove the old cable.
i. Cut off the cable strap.
ii. Disconnect the connector at end A of the old cable.
iii. Remove the old cable.
4. Lay the new dry contact input/output cable.
i. Lay the new cable according to the cabling direction and
line order of the old cable. When laying the cable, conform
with the technique requirement of the cable binding of the
equipment.
ii. Connect end A of the new cable to the SA panel cable and
fix it.
5. Check the cable replacement result.
Check whether the board related with the replacement cable
works normally and whether the related alarms are generated
in the alarm management system.
6. After the replacement, tidy the site and dispose the replaced
old cable properly.
END OF STEPS

Confidential and Proprietary Information of ZTE CORPORATION 35


ZXSDR B8200 L200 Maintenance Guide

Replacing GPS receiving


Antenna Cable
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old GPS receiver antenna
cables are the same.
Context The GPS receiver antenna cable in the ZXSDR B8200 L200 system
is used to import the GPS antenna signal to the SMA antenna in-
terface of the CC.
Steps 1. Twist off the interface of the cable connected to the GPS an-
tenna feeder.
2. Twist off the interface of the cable connected to the CC.
3. Cut off the cable strap and remove the GPS receiver antenna
cable.
4. Connect the corresponding end of the new GPS receiver an-
tenna cable to the interface of the SMA antenna of the CC.
5. Connect the corresponding end of the new GPS receiver an-
tenna cable to the GPS antenna feeder.
6. Fix the cable with the cable strap.
7. After the replacement, tidy the site. Dispose the replaced GPS
receiver antenna cable properly and tidy the site.
END OF STEPS

Replacing NetNumen/LMT
Cable
Prerequisites � Wear the antistatic wrist strap.
� Ensure that the types of the new and old Ethernet cables are
the same.
Context When you use the LMT/NetNumen software to implement the op-
eration and maintenance, the OAM NetNumen/LMT cable is the
information transmission media between the operation and main-
tenance end and the equipment. When replacing the cable, do not
implement operation and maintenance on the equipment.
Steps 1. Remove the faulty cable.
Pinch the turnup of the cable connector and pull out the cable.
2. Lay the new Ethernet cable and bind the cable.
Cut off the cable strap, remove the replaced old Ethernet cable,
and then lay the new Ethernet cable. When binding the cable,
conform with the technique requirement of the Ethernet cable
binding.

36 Confidential and Proprietary Information of ZTE CORPORATION


Chapter 6 Replacing Cables

3. Install the Ethernet cable. Insert the connector into the cable
interface according to the shape of the cable interface.
4. Check the Ethernet cable replacement result.
Check whether the board related with the replacement Ether-
net cable works normally and whether the related alarms are
generated in the alarm management system.
5. Paste the engineering labels on the Ethernet cable.
Paste the engineering labels on the Ethernet cable. The con-
tents in the labels of the new Ethernet cable should be the
same as that of the old Ethernet cable.
6. After the replacement, tidy the site and dispose the replaced
old Ethernet cable properly.
END OF STEPS

Replacing Fiber Cable


Context When replacing the fiber, pay attention to the following precau-
tions:
� Do not break the protection layer of the fiber during the oper-
ation.
� Do not contaminate the fiber connector.
� Do not overexert on pulling out the old fiber or binding the new
fiber.
� Curve the turning point of the new fiber.
Steps 1. Confirm the type of the new fiber.
Before replacing the fiber, ensure that the types of the new
fiber and the old fiber to be replaced are the same.
2. Paste temporary labels on the new fiber.
Paste temporary labels at two ends of the new fiber to form
the matching relation. Differentiate the fibers by labels in the
case that more than one fiber need to be replaced.
3. Lay the new fiber.
The position and cabling mode of the new fiber must be the
same as that of the old fiber.
4. Disconnect one connector of the old fiber and connect the con-
nector of the new fiber.

Confidential and Proprietary Information of ZTE CORPORATION 37


ZXSDR B8200 L200 Maintenance Guide

Caution:
� Remove one connector of the old fiber to be replaced, and
cover the optical interface with the protective cap to pre-
vent it being contaminated.
� Insert the connector of the new fiber and ensure that the
connector is clamped firmly.

5. Remove the other connector of the old fiber and insert the con-
nector of the new fiber.
Find the connector at the other end of the old fiber according
to the number of the old fiber and remove the connector. Find
the connector at the other end of the new fiber according to
the temporary label of the new fiber and insert the connector.

Caution:
� Remove one connector of the old fiber to be replaced, and
cover the optical interface with the protective cap to pre-
vent it being contaminated.
� Insert the connector of the new fiber and ensure that the
connector is clamped firmly.

6. Check the fiber replacement result.


Check whether the board related with the replacement fiber
works normally and whether the related alarms are generated
in the alarm management system.
7. Bind the new fiber.
Cut off the cable strap, remove the replaced old fiber, and then
lay the new fiber. When binding the fiber, conform with the
technique requirement of the fiber binding.
8. Paste the engineering labels on the fiber.
Remove the temporary labels on the new fiber and paste the
engineering labels on the fiber. The contents in the labels of
the new fiber should be the same as that of the old fiber.
9. After the replacement, tidy the site.
Dispose the replaced old fiber properly, and tidy the site.
END OF STEPS

38 Confidential and Proprietary Information of ZTE CORPORATION


Figures

Figure 1 RS232/RS485 monitoring cable ...............................32


Figure 2 Appearance of the SA panel cable............................32
Figure 3 Input/Output dry-contact interface cable ..................34
Figure 4 Appearance of the SA panel cable............................35

Confidential and Proprietary Information of ZTE CORPORATION 39


ZXSDR B8200 L200 Maintenance Guide

This page is intentionally blank.

40 Confidential and Proprietary Information of ZTE CORPORATION


Tables

Table 1 Basic Maintenance Information Record........................ 5


Table 2 ZXSDR B8200 L200 version information...................... 6
Table 3 Daily maintenance items........................................... 9
Table 4 Monthly maintenance items....................................... 9
Table 5 Quarterly maintenance items ...................................10
Table 6 Semiannual maintenance items ................................12
Table 7 Annual maintenance items .......................................12
Table 8 Signal descriptions of the RS232/RS485 monitoring
cable ...............................................................33

Confidential and Proprietary Information of ZTE CORPORATION 41


ZXSDR B8200 L200 Maintenance Guide

This page is intentionally blank.

42 Confidential and Proprietary Information of ZTE CORPORATION


Glossary

CC
- Control and Clock Module
FA
- Fan Array Module
FDD
- Frequency Division Duplex
IP
- Internet Protocol
LMT
- Local Maintenance Terminal
LTE
- Long Term Evolution
MicroTCA
- Micro Telecommunication Computing Architecture
OMC
- Operation & Maintenance Center
PM
- Power Module
SA
- Site Alarm Module
SDR
- Software Defined Radio
eNodeB
- Evolved NodeB
eRRU
- evolved Remote Radio Unit

Confidential and Proprietary Information of ZTE CORPORATION 43