Sei sulla pagina 1di 1

PROJECT:

DATE:
SHEET NO.:

REF CALCULATIONS OUTPUT


DESIGN OF STAIR SLAB

Using stair slab layout of first floor slab load to design the
stair slab
The flight of the steps from ground floor to the first floor is 10 Risers
made up of 2 set of 10 equal risers of 150mm and 9 eqaul 9 Treads
treads of 300mm. 175 waist
149 d-effective
10 Risers of 150 mm 1.50 m fcu = 20 N/mm2
9 treads of 300 mm 2.70 m fy = 410 N/mm2
Effective Span = 4.00 m
Slope length = (1.5 + 4.75 )
2 2 1/2
= 4.27 m 1000 slope width

STAIR SLAB LOAD


Gk = ((0.175x3.09)+(0.3x1.5/2))x24 = 22.200 Kn/m
Qk = 3 x 3.09 = 12.816 Kn/m
F = 1.4Gk + 1.6Qk = 51.586 Kn/m

Taking a waist depth of 175mm and 1m slope width

STAIR SLAB REINFORCEMENT


M = Fl/8 = 25.793 Kn/m
M
/fcubd2 = 0.058
la = 0.93
As(Reqd) = 477.55 mm2
As(Provd) = 566 mm2 i.e Y12 @ 200mm c/c btm

CHECK DEFLECTION Reinforcement


M
/
bd
2
= 25.793x10 /1000x1492 =
6
1.16 Y12 @ 200mm c/c
fs = 230.62 mf = 1.55 Y12 @ 200mm c/c
100As
/bd = 100x566/1000x149 = 0.38 %
dreq = 4000/20x1.55 = 129.381 mm
dprov = 149 > 129.381 Deflection is OK
DISTRIBUTION REINFORCEMENT
100AS/bh = 0.24%
As (Reqd) = (0.24x1000x175)/100 = 420 mm2
As (Provd) = 566mm2 i.e. Y12 at 200mm c/c

Potrebbero piacerti anche