PRODUCT NAME
Please read this manual prior of using the air dryer. Keep the manual readily available for
reference.
This opertion manual must be read and understood throughoutly before handling. It provides all essential
information for maximizing product operating efficiency, as well as, for safe and longer life span operation.
For safety operation of SMC Refrigerated Air Dryer, read thoroughly and follow stated safety instructions, as well
*1 *2
as regulation stated within ISO 4414 & JIS B 8370 .
*1) ISO 4414: Pneumatic fluid power – Recommendations for the application of equipment to transmission
and control systems.
*2) JIS B 8370: Pneumatic fluid power – General rules relating to systems
This manual explains about installation and operation of the product. Only those who have thorough
understanding of the fundamental operating procedure or have basic knowledge and skills of handling industrial
product for the installation and operation of the product are qualified to perform installation and operation.
The contents of the operation manual and the other documents attached to the product cannot become a part of
the contract clause or cannot change and modify existing agreements, promises, and relationship.
Any statements contained in the operation manual cannot be newly guaranteed and modify existing guarantee
certificate.
You are not allowed to copy any part of this operation manual for usage of third person without informing it to us
beforehand.
Caution: Please understand that the contents of this operation manual are subject to
changed without previous notice.
Air Dryer Table of Contents
Table of Contents
To Customers
Chapter i Safety Instructions
i-1 Warning: Before Using Air Dryer .......................................................................... i - 1
i-1-1 Meanings of signs: Caution, Warning, Danger .......................................................... i - 1
i-2 Danger Classifications / Position of Danger warning label ............................ i - 3
i-2-1 Danger Classifications ............................................................................................. i - 3
i-2-2 Danger of Electricity ................................................................................................. i - 4
i-2-3 Danger of high Heat ................................................................................................. i - 4
i-2-4 Danger of Rotor ....................................................................................................... i - 4
i-2-5 Danger of Compressed Air Circuit ........................................................................... i - 4
i-2-6 Positions of Danger Warning Label .......................................................................... i - 5
i-2-7 Danger of Refrigerant............................................................................................... i - 6
i-2-8 Cautions about Usage.............................................................................................. i - 7
i-2-9 Other Label .............................................................................................................. i - 7
i-3 Disposal .....................................................................................................................i – 8
i-4 Limited warranty and Disclaimer / Compliance Requirements ......................i – 9
Chapter 1 Parts Name and Functions
1-1 Parts Names and Functions.................................................................................. 1 - 1
Chapter 2 Transportation / Installation
2-1 Transportation.......................................................................................................... 2 - 1
2-2 Installation ................................................................................................................ 2 - 2
2-2-1 Location .................................................................................................................. 2 - 2
2-2-2 Anchorage .............................................................................................................. 2 - 2
2-2-3 Air piping................................................................................................................. 2 - 3
2-2-4 Drain Tube .............................................................................................................. 2 - 3
2-2-5 Electric wiring.......................................................................................................... 2 - 4
2-3 Cautions about reinstallation ............................................................................... 2 - 5
Chapter 3 Operation / Shutdown
3-1 Check points before operation ............................................................................. 3 - 1
3-2 Operation .................................................................................................................. 3 - 1
3-3 Shutdown .................................................................................................................. 3 - 2
3-4 Cautions about restart ........................................................................................... 3 - 2
3-5 Check points before restart .................................................................................. 3 - 2
3-6 Precautions for long-term non-operation ..................................................... 3 - 2
Chapter 4 Maintenance
4-1 Daily inspection ....................................................................................................... 4 - 1
4-2 Periodical maintenance ......................................................................................... 4 - 1
4-2-1 Cleaning of ventilation grille (suction grille).................................................................. 4 - 1
4-2-2 Service parts .............................................................................................................. 4 - 1
4-2-3 Cleaning of the case assembly ................................................................................... 4 - 1
Chapter 5 Troubleshooting ............................................................................................................ 5 - 1
5-1 Cause and countermeasure of errors................................................................. 5 - 1
5-2 How to reset the thermal relay and high pressure switch ............................. 5 - 2
Chapter 6. References
6-1 Specifications .......................................................................................................... 6 - 1
6-2 Refrigerant with GWP reference ......................................................................... 6 – 1
6-3 Dimensions............................................................................................................... 6 - 2
6-4 Electrical Circuit ...................................................................................................... 6 - 3
6-5 Compressed Air and Refrigerant Circuit / Operation Principles................... 6 - 4
Table of Contents - 1
Air Dryer i Safety Instructions
i Safety Instructions
Danger
Statements with the “Danger” sign explain about conditions in which there is a
possible result of serious injury or loss of life if someone handles wrongly during
operation or maintenance and did not follow the procedure to avoid danger.
i-1
Air Dryer i Safety Instructions
Warning
Statements with the “Danger” sign explain about possibilities that can result in
serious injury or loss of life if someone handle wrongly during operation or
maintenance and did not follow the procedure to avoid danger.
Caution
Statements with the “Danger” sign explain about possibilities that can result in injury
or product damage if someone handles wrongly during operation or maintenance and
did not follow the procedure to avoid danger.
i-2
Air Dryer i Safety Instructions
Warning
No one but professionals should operate an air dryer.
Transportation, installation, and maintenance involve risks. These should be done by
someone who have enough knowledge and experience about this product and incidental
devices.
No one but our service personnel or qualified person should open the cover panel of this
product.
Warning
Should any problem occur, address it according to statements on this manual.
• Identify problems according to “Chapter 5 Troubleshooting.”
• Ask repair and maintenance.
Warning
The product should not be operated in the event of any problems.
When the product gets out of order, shutdown it immediatery, and contact our service
person or qualified person.
Danger of Electricity
Since this product runs at hign voltage, there is the danger of electric shock. So, we display
a symbol with indications, “Caution”, “Warning” or “Danger,” on the product and this
manual.
Danger of Heat
Since this product becomes hot while driving, there is the danger of burn injury. So, we
display a symbol with indications, “Caution”, “Warning” or “Danger,” on the product
and this manual.
Danger of Rotor
Since this product has parts that rotate while driving, there is the danger of catching your
fingers in or injury. So, we display a symbol with indications, “Caution”, “Warning” or
“Danger,” on the product and this manual.
i-3
Air Dryer i Safety Instructions
i – 2 – 2 Danger of Electricity
Inside of this product, there is power-supplying section with high voltage separated by the
cover panel. Do not operate the product without the cover panel.
No one but trained qualified person should operate or inspect in the power transmission
sections.
Warning
Read with caution and pay attention to the notations on danger warning labels.
Do not remove or rub danger warning labels.
Confirm the positions of danger warning labels.
i – 2 – 4 Danger of Rotor
Warning
Since this product has parts that rotate during operation, there is the danger of burn injury
resulting from contact with them. Though sometimes those parts can temporarily stop the rotation,
they will rotate again, and so do not work with them while driving.
i-4
Air Dryer i Safety Instructions
! WARNING 警告
1 Remove panels for maintenance only.
2 Never insert anything into product to ensure
safety.
1 点検以外はパネルを取り外さないこと。
2 回転物があるので指、棒状の物を差し
込まないこと。
3 感電の恐れがあるので、点検の前には電源を
切ること。
4 火傷の恐れがあるので、点検の前には装置を
常温にすること。
5 部品交換の前には必ず、空気圧力を"0"に Front
すること。
i-5
Air Dryer i Safety Instructions
This product is specified by “Class 1 Fluorocarbon Collection and Destruction Law in Japan.”
It is strictly forbitten to emit Fluorocarbon to the atmosphere. Before you repair this product,
you should collect the refrigerant with “Refrigerant collector.” Then, ask a destruction agency
to dispose of collected refrigerant. No one but someone have enough knowledge and
experience about the product and incidental device should do the collection of the refrigerant.
No one but service person or qualified person should remove the cover panel of the product.
The quantity and the sort of the Fluorocarbon are mentioned on the specification label that are
explained on Page i – 8.
Front
i-6
Air Dryer i Safety Instructions
! CAUTION 注 意
1 Read manual before operation.
2 Ensure vantilation and maintenance
space.
3 Keep water away from the product.
4 Secure In / Out connector with spanner
during piping.
5 Wait 3 minutes before restart.
6 Ensure Running Condition / Evaporating
Tem p. in green zone.
1 ご 使 用 前 に 必 ず 取 扱 説 明 書 を 読 ん で くださ い 。
2 通 風 、 メ ン テ ナ ン ス ス ペ ー ス を 確 保 して
くだ さ い 。
3 雨 や 水 滴 が か か ら な い よ う に して くだ さ い 。
4 IN / O U T ポ ー トを ス パ ナ で固 定 して
配 管 して くだ さ い 。
5 再 起 動 は 運 転 停 止 3 分 後 に 行 っ て くだ さ い 。
6 R U N N IN G C ON D IT IO N ・蒸 発 温 度 計 は
グ リ ー ン 帯 で 使 用 し て くだ さ い 。
Front
i – 2 – 9 Other Label
Comfirm the model, contents of specifications on the label.
Specification Label
Front
i-7
Air Dryer i Safety Instructions
i–3 Disposal
When you dispose of the product, you shoud collect the refrigerant and the refrigerat oil enclosed in the
refrigerant circuit.
Caurion
A sort of Fluorocarbon (HFC) is used for this product as refrigerant.
No one but someone have ebough knowledge and experience about the product and
incidental devices should do the collection of the refrigerant.
No one but service person or qualified person shoud remove the cover panel of the product.
The quantity and the sort of the Fluorocarbon are printed on the specification label.
Caution
Dispose of the refrigerant and refrigerant oil according to the bylaw or regulation of local
government.
Do not dispose of refrigerant oil together with domestic garbage. And do not burn it in
unauthorized incinerators.
No one but someone have enough knowledge and experience about the product and
incidental devices should do the collection of the refrigerant oil.
No one but service person or qualified person shoud remove the cover panel of the product.
If there are something not clear, please contact our service office.
i–8
Air Dryer i Safety Instructions
The product used subject to the following “Limited warranty and Disclaimer“ and “Compliance Requirements.
Read and accept them before using the product.
1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered.
Also, the product may have specified durability, running distance or replacement parts. Please consult
your nearest sales branch.
2. For any failure or damage reported within the warranty period which is clearly our responsibility, a
replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any other damage incurred
due to the failure of the product.
3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in
the specified catalog for the particular products.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass
destruction (WMD) or other weapon is strictly prohibited.
2. The exports of SMC products or technology from one country to another are govemed by the relevant
security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC
product of a SMC product to another country, assure that all local rules goveming that export are known
and followed.
Caution
The Product is provided use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and exchange
specifications or a contact if necessary.
If anything is unclear, contact your nearest sales branch.
i–9
Air Dryer 1 Name and Functions Parts
・IDF22E to 75E
Compressed Air (OUT)
Switch with Lamp Compressed Air (IN)
(ON/OFF Switch)
The lamp is continuously ON
during normal operation. Use it
for ON/OFF operations.
Right Side Ventilation
Grille (Outlet)
Evaporation
Waste heat will be exhausted
thermometer
as hot air by the fan motor. Do
(EVAPORATING TEMP)
not block with wall and so on.
Indicates the temperature
of refrigerant of Ball Valve
low-pressure side.
During normal driving, it Auto Drain
indicates in the green Check if drained
zone. correctly once a day.
Terminal block
You can see the terminal block when you remove front panel. Connect the power
cablethrough the rubber grommet.
IDF22E-20, IDF37E-20 IDF22E-30, IDF37E-30, IDF55E-30,
(Single phase AC200V) IDF75E-30 (3 phase AC200V)
L N PE( ) L1 L2 L3 PE( )
1-1
Air Dryer 1 Name and Functions Parts
Front
Rubber Grommet
Power cord outlet
1-2
Air Dryer 2 Transportation / Installation
2 Transportation / Installation
Warning
Use the product in the right way. During Installation, operation, maintenance, and check,
you should be careful in keeping the safety of human body.
Caution
Transportation, installation, and maintenance including dangerous work must be done by
a personnel who has enough knowledge and experience about the product and the
sysytem.
2-1 Transportation
When you transport the product, you should follow these instructions below.
• You should uplift the product from the base surface with careful attention to prevent falling sideways and
drop.
• Do not bring the product lying sideways. If you lay it sideways, it will be broken.
• Do not hang up the product.
• Do not transport the product with any part such as an air filter mounted on the fittings at the air inlet or
outlet port of the product. If it is unavoidable to transport the product with such a part mounted, support
the part with a bracket to prevent the product from being affected by vibration during transportation.
Warning
Those instructions above must be followed because the product is so heavy that it carries
a great risk to transport.
IDF22E to 75E are 54 to 116kg or more. They must be transported by more than 4 person, a
forklift and so on of IDF22E and IDF37E. They must be transported by forklift of IDF55E
and IDF75E.
2-1
Air Dryer 2 Transportation / Installation
2-2 Installation
2-2-1 Location
The product should not be used or stored in the circumstances as follows.
Those circumstances will cause not only malfunction but also failures.
• Environment where the product is • Locations where danger of thunder is
exposed to rainwater, moisture vapor, apparent.
salty water, oil and so on. • Locations by loading on vehicles,
• Locations where dust or particles are. marine vessels, and so on.
• Locations where inflammable or • Locations whose altitude is higher than
explosive gas are. 2,000 meters.
• Locations where corrosive gas, solvent, • Circumstances where strong vibration
combustible gas are. or impact are transmitted.
• Locations that receive direct sunlight or • Circumstances where too much force
where radiant heat is generated. and weight are put on the body of the
• Locations where ambient temperature product that causes it to deform.
is beyond following range: • Circumstances where enough spaces
o
On-stream: 2 to 40 C cannot be taken to do maintenance (in
o
Storage: 0 to 50 C (when there is no the plant where the product is
drain water inside of the piping) operated).
• Locations where temperature changes Spaces needed for maintenance
rapidly. Front : 600 mm
• Locations where strong Rear : 600 mm
• electromagnetic noise is generated Top : 600 mm
(locations where electromagnetic field, Right : 600 mm
strong magnetic field, surge is Left : 600 mm
generated) • Locations the ventilation grille of the
• Circumstances where static electricity product can be blocked.
is produced or discharged through the • Place where rejection style air of air
body of the product. compressor or other driers (hot wind) is
• Locations where strong high frequency inhaled.
wave is generated.
Warning
Do not use and store in environment having compressed air or ambinet atmosphere which
includes the following substances. It could result in failure of the product and damage of
components, which leads to injury.
- Corrosive gas, Organic solvent, Chemicals
2-2-2 Anchorage
• The air dryer should be installed on a vibration-free, stable, horizontal flat surface.
• Refer to “Chapter6 6-2 Dimensions” for the dimensions.
• Fix by bolts to prevent falling down. The bolts can be prepared separately as an accessory.
Model No. Name Quantity Applicable Model
IDF-AB500 Anchor bolt set 1(4pcs/1set) IDF22E,IDF37E,IDF55E,IDF75E
2-2
Air Dryer 2 Transportation / Installation
Compressed Air (OUT) Compressed Air (IN) We recommend the bypass piping sets that
we are selling separately as accessories.
Applicable
Valve (OUT) Valve (IN) Model No. Name Q.t
Model
Bypass
IDF-BP317 1 IDF22E
valve
Union Joint Union Joint Bypass
IDF-BP318 1 IDF37E
piping
sets IDF55E
IDF-BP325 1
IDF75E
2-3
Air Dryer 2 Transportation / Installation
Wiring procedure
・Remove the front panel.
・Insert the cord through the rubber grommet and connect it to the terminal block (refer to the label on the terminal
block).
M3 screw tightening torque: 0.6 to 1Nm
During wiring work, do not touch other sections except terminal block.
・Attach the front panel as it were.
2-4
Air Dryer 2 Transportation / Installation
If you move the product and reinstall it into another place after some operations (including trial running), instructions
that are not only following ones but also all of those in the chapter 2 should be followed.
Warning
No one but qualified personnel should do the electric wiring.
Cut off the power supply for safety before the wiring. Do not work under energized
condition.
Warning
No one but qualified personnel should do the air piping.
Separate the compressor from the product for safety before removing the iping. Do not
remove any piping when there is remaining compressed air pressure inside of it.
Remove the seal tape completely after detaching the piping. Remained tape will cause imperfect cooling
and failure by entering into the body of the product.
Case Assembly
2-5
Air Dryer 3 Operation / Shutdown
3 Operation / Shutdown
Caution
No one but someone who has enough knowledge and experience about the product and
incidental devices should operate or shut down the product.
3-2 Operation
Start operation according to the procedure below.
• Turn on the breaker of the main power supply. Then, turn on the illuminated switch.
• The lamp will light up. Few minutes later, the cooling fan will rotate and hot air will be exhausted from the
ventilation grille.
Place of the ventilation grille: Right Side Ventilation Grille
• Open the IN / Out side valve slowly. Make sure the bypass valve is completely closed. Make sure the bypass
valve is completely closed. Confirm there is no air leakage.
• Depending on the condition of compressed air or ambient temperature, the cooling fan sometimes alternates
between rotation and stop at the beginning. Then, the refrigerator will go into continuous run and the pointer of
the evaporation thermometer will indicate in the green zone. If the pointer of the evaporation thermometer
indicates higher than the green zone, refer to “Chapter5 Troubleshooting.”
• After a while from the start of flowing the compressed air, drain will be discharged from the drain tube
automatically.
• Keep the condition of continuous run to use.
3-1
Air Dryer 3 Operation / Shutdown
Caution
Avoid frequent On/Off operation, which can cause troubles.
The auto drain used for the product has a structre that closes the valve with air pressure higher
than 0.15MPa. Therefore, until the pressure increase, air will be emitted form the drain outlet at
the begining of opening the IN side valve. Keep in mind that sometime the pressure cannot
increase enough with air compressor that has low dischage flow rate.
3-3 Shutdown
• Turn off the illuminated switch.
• The lamp will go out and then, the operation will be stopped. Depending on the condition of operation, hot air
continues to be emitted from the ventilation grille by the cooling fan for a while after turning off the switch,
which is not an abnormality but a process for safety shutdown.
3-2
Air Dryer 4 Maintenance
4 Maintenance
4-1 Daily Inspection
Check following points during usual operations. If you find some problems, immediately stop the operation and refer to
“Chapter 5 Troubleshooting” as soon as possible.
• There is no air leakage
• The running lamp is lighting during operation
• Drain is being discharged from drain tube
• The pointer of the evaporation thermometer indicates in the green zone when it is running with pressurized air
supply.
o
• The pointer of the evaporated thermometer indicates about 3 to 10 C lower than that of ambient temperature
when the product is suspended with no pressurized air supply.
• There is no abnormal sound or vibration coming up from the product.
• There are no abnormal smell or smoke coming up from the product.
Caution
During air blowing, put on protective glass and mask to prevent dusts from coming
into throat or eyes.
*Note)If it is mounted by option ”T” (With terminal block for power supply , run , alarm signal and remote
operation) or special order.
4-1
Air Dryer 4 Maintenance
Warning
・ Maintenance of the air dryer should only be carried out by someone with sufficient knowledge and
experience of air dryers and related equipment.
・ Before carrying out maintenance, the important warnings in this manual must be thoroughly read and
understood.
Danger
・ When replacing or cleaning parts of the air dryer, be sure to remove the compressed air pressure inside
the air dryer to “0”. Never remove the case assembly when the air dryer is operated or air pressure
remains inside. It is extremely dangerous if compressed air pressure remains inside the air dryer, as
parts may come flying off at speed when loosened, or other unexpected accidents.
・ This product has parts that become hot during operation and a power supply with high voltage applied.
There is a risk of burns due to heat or electrification by high voltage. Even when operation is shut down
after switching off the air dryer’s illuminated light, there are also charging lines. When working on the
charged sections, be sure to switch off the earth leakage breaker installed before starting work.
・ As some parts of the air dryer will remain hot, there is a risk of burns due to residual heat after the
power is switched off. So do not carry out replacement work until the temperature of these parts has
fallen to 50℃ or less. Wait for about 10 to 15 minutes as a guide.
・ When carrying out maintenance work on the auto drain strainer and auto drain, there is a risk of
touching the drain fluid during work. Please follow the safety procedure for operators specified by
customer.(Example: carry out work wearing safety glasses, apron and gloves to prevent discharged
fluid from touching the human body.)
・ Use neutral detergent solution to clean parts such as the auto drain strainer and auto drain. Never
use solvent such as thinner.
・ When removing the outer casing panel or case assembly of the auto drain, wear gloves to prevent
injuries.
4-2
Air Dryer 4 Maintenance
Bleed valve
Drrain tube
Float assembly
4-3
Air Dryer 5 Troubleshooting
5 Troubleshooting
5-1 Cause and countermeasure of errors
Should any problem occur, inspect the following table, and if the problem cannot be solved, shut off the power supply
and then contact one of our sales offices for further instructions.
Problem Probable Causes Remedy
Air dryer does not Power cord or plug is in loosening Perform proper connection on the power cord and plug.
operate and running state or completely pulling out.
lamp does not light Circuit breaker is OFF. Confirm whether the proper capacity of the circuit
on, even switch is breaker is used.
ON. It is not possible to restart the air dryer within 3
minutes after shutdown. Wait for 3 minutes before
restarting.
Resume the operation after resetting the circuit
breaker to ON. If the circuit breaker still trips to OFF,
failure of electrical insulation may have occurred.
Remove the power supply and contact one of our
agents for further instructions.
Connect the 3-phase power supply Replace 2 wires (R phase and T phase) among 3 each
incorrectly. (Applicable to products other.
using the 3-phase power supply.)
Running lamp Installation place is poorly Improve the ventilation system to lower the ambient
extinguishes and ventilated. Ambient temperature temperature.
compressor stops is too high. Reset the protective circuit referring to “5-2 How to reset
during operation but the thermal relay and high pressure switch”.
resumes normal The ventilation grilles are Install the air dryer more than 600mm away from the
operation obstructed by wall or clogged wall.
illuminating the with dust. Clean the ventilation grilles once a month.
lamp after a Reset the protective circuit referring to “5-2 How to reset
period of time. the thermal relay and high pressure switch”.
Temperature of the compressed Improve the ventilation system around air
air is too high. compressor or make ambient temperature around air
compressor low to lower the temperature of
discharge from compressor.
Reduce the temperature of the compressed air by
installing an additional after-cooler after air dryer.
Reset the protective circuit referring to “5-2 How to reset
the thermal relay and high pressure switch”.
The power supply voltage changes Install a power supply transformer and review the power
largely. supply to keep the voltage adequate value.
Allowable fluctuation of the power supply voltage is
+-/10% at max. of the rated voltage.
Reset the protective circuit referring to “5-2 How to reset
the thermal relay and high pressure switch”.
Evaporation Installation place is poorly Improve the ventilation system to lower the ambient
thermometer points ventilated. Ambient temperature temperature.
the value exceeding is too high.
a green range under The ventilation grilles are Install the air dryer more than 600mm away from the
the condition where obstructed by wall or clogged wall.
no hot wind blows out with dust. Clean the ventilation grilles once a month.
from the ventilation Temperature of the compressed ・Improve the ventilation system around air
port (exhaust port) at air is too high. compressor or make ambient temperature around air
right side face. compressor low to lower the temperature of
(Refrigerating discharge from compressor.
compressor stops Reduce the temperature of the compressed air by
with light on.) installing an additional after-cooler after air dryer.
5-1
Air Dryer 5 Troubleshooting
Evaporation Installation place is poorly Improve the ventilation system to lower the ambient
thermometer points the ventilated. Ambient temperature temperature.
value exceeding a is too high.
green range under the The ventilation grilles are Install the air dryer more than 600mm away from the
condition where no hot obstructed by wall or clogged wall.
wind blows out from the with dust. Clean the ventilation grilles once a month.
ventilation port (exhaust Temperature of the compressed Improve the ventilation system around air
port) at right side face. air is too high. compressor or make ambient temperature around air
compressor low to lower the temperature of
discharge from compressor.
Reduce the temperature of the compressed air by
installing an additional after-cooler after air dryer.
Moisture occurs Bypass valve of air dryer is not Close the valve completely.
downstream of the fully closed.
compressed air Drain is not discharged from auto Check if the drain pipe has been raisen up or bent.
lines. drain properly. Check auto drain.
Check auto drain strainer.
Confluence of piping with another Install air dryer on the line that does not have it.
unit without air dryer. Separate two lines not to converge.
Large pressure drop IN / OUT valve on the air dryer Open IN/OUT valve thoroughly.
side is not fully opened.
Filter that is installed separately Replace the filter element.
in compressed air line is clogged. (Follow the instruction manual of each individual
device.)
5-2
Air Dryer 5 Troubleshooting
5-2 How to reset the thermal relay and high pressure switch
If light goes off during operation and refrigerating compressor stops, the thermal relay or high pressure switch
(for only the IDF55E and IDF75E) to protect the refrigerating compressor starts operating and needs to be
reset manually. For the position of the thermal relay and high pressure switch, refer to page 1-1.
Remove causes to start the thermal relay or high pressure switch referring to “5-1 Cause and countermeasure
for errors”.
Danger
Be sure to turn off the switch with light of the body.
High pressure
How to reset a high pressure switch
switch bracket Rest button
1. Turn off the switch with lamp of the body.
2. Take off the front panel. The high pressure switch can (Red)
be found at upper right part of power supply terminal base. +
5-3
Air Dryer 6 References
6 References
6-1 Specifications
Model
IDF22E-20 IDF22E-30 IDF37E-20 IDF37E-30 IDF55E-30 IDF75E-30
Specification
Air Flow Rate 50Hz 3.9 5.7 8.4 11.0
Rated Condition
o
Inlet Air Temperature C 5 to 50
Inlet Air Pressure MPa 0.15 to1.0
o
Ambient Temperature C 2 to 40 (Relative Humidity of 85% or less)
Power source Phase Single Three Single Three
Specification
AC200(50Hz) / AC200,220(60Hz)
Electrical
(Note 4) Voltage V
Operating urrent(Note 2) A 4.3 / 4.7 3.3 / 3.5 4.3 / 4.7 3.3 / 3.5 5.0 / 5.4 7.2 / 8.1
Power consumption(Note 2) W 810 / 940 850 / 1070 810 / 940 850 / 1070 1300 / 1700 2000 / 2500
Circuit Breaker(Note 3) A 10 15
Condenser Air cooling
Refrigerant R407C (HFC)
Refrigerant Charge g 420±10 470±10 730±10 830±10 1000±10 720±10
Air IN/OUT Connection R1 R1・1/2 R2
Drain Connection mm 10
Panel: Urbanwhite 1
Coating Color
Base: Urbangray 2
Weight kg 54 62 100 116
Applicable Compressor(Standard) kW 22 37 55 75
3
Note1: The data for m /h (ANR) is referring to the conditions of 20°C, 1atm. pressure & relative humidity of 65%.
Note 2: The value is that of under specified condition.
Note 3: Install GFCI breaker with sensivity of 30mA.
Note 4: When short period power shortage (including instantly recovered shortage) is recovered, it may take a longer starting
period than usual starting or may not start due to the protective devices.
6-1
Air Dryer 6 References
6-3 Dimentions
IDF22E, IDF37E
AIR OUTLET AIR INLET
PORT SIZE PORT SIZE
A B
G E D
SWITCH
WITH LAMP
EVAPORATION
THERMOMETER
DRAFT
BALL VALVE F AIR OUTLET
VENTILATION VENTILATION
C
TERMINAL
BLOCK
DRAIN TUBE
(O.D.10)
(820)
L K
J
H N M
P
POWER SUPPLY ENTRY(φ17) 4-φ13
[OTHER SIDE]
measure:mm
Model Port size A B C D E F G H J K L M N P
IDF22E R1 775 600±1
290 623 (134) (405) (698) (93) 46 25 13 314 85 340
IDF37E R1 ・1/2 855 680±1
IDF55E, IDF75E
SWITCH
WITH LAMP DRAFT AIR OUTLET
EVAPORATION
THERMOMETER
BALL VALVE
TRMINAL
AUTO DRAIN
F
BLOCK
C
VENTILATION
VENTILATION
DRAIN TUBE
(O.D.10,
LENGTH:1m)
J
L K
P H N M
ELECTRICAL ENTRY 4-φ13
(WIREφ 9 ∼` 11)
[OPPOSITION]
measure:mm
Model Port size A B C D E F G H J K L M N P Q R
IDF55E 800 (868)
R2 470 855 (128) (455) (110) 36 50 13 500 75 700±1 526 (250) 519±5
IDF75E 900 (968)
6-2
Air Dryer 6 References
PRR
ILS
MC THR THR
MC
CM
THR CM
MC
C01
ILS
OLR
MC THS THR
θ PRR
C11
FM C11
PRS FM
PRS
P
P
PRR PRR
THR THR
MC MC1
CM CM
OLR
ILS ILS
6-3
Air Dryer 6 References
Drain
Refrigerant Circuit
The Fluorocarbon charged in the refrigerant circuit is compressed by the compressor and cooled by the condenser to
become liquid. Then, going through the capillary tube, it is decreased the pressure to reach a low temperature. Passing
through the cooler part, it draws heat from compressed air and intensely boils. Finally it is inhaled into the compressor
again. The capacity control valve opens to prevent dew drops from freezing when compressed air is cooled enough.
6-4