Sei sulla pagina 1di 6

BURAXNO

UTILITY CONSUMPTION LIST

YARA PILBARA
NITRATES PTY LTD

TAN BURRUP PROJECT


TR PROJECT NO. 02080 12-NITRIC ACID PROCESS UNIT

REQUISITION FOR PURCHASE ORDER


ALL
NUMBER (RFP): 2-300-329-RFQ-TRE-5301
PURCHASE ORDER NUMBER:
0208005060 MODULE NUMBER: VPU-1211 TO VPU 1216

REVIEW RESPONSE BY PURCHASER:


Purchaser review and comments do not indicate either responsibility or liability for accuracy
and completeness of this document or alter any contractual terms and conditions:

Rejected Reviewed With Comments Reviewed As Built

Comment as Noted Rev. With Comments For Information

DATE:

DOCUMENT DATA VENDOR INDENTIFICATION:

DOCUMENT TITLE: UTILITY CONSUMPTION LIST

VENDOR DOCUMENT NO.: 10001381241 REV: 06 CODE: LIS-0007

TR DOCUMENT NO.: V-02080-12-CD-001-0056 REV: 06 CATEGORY:

CLIENT DOCUMENT NO.: 2-300-329-VEN-MDT-0075 REV: 06

06 Schrader, Stefan 06.06.2014 Schrader, Stefan 06.06.2014 FINAL


REV. CHANGED DATE CHECKED / RELEASED DATE CHANGE NO. CHANGE DESCRIPTION
Schrader, Stefan 23.11.2012 Schrader, Stefan 23.11.2012 Schrader, Stefan 23.11.2012
ISSUED DATE CHECKED DATE RELEASED DATE
TRAIN HNO3 PROJECT NO. H.0100041.01
SHEET UTILITY CONSUMPTION LIST PROJECT BURAXNO
DOCUMENT NO. 10001381241 DOC. TYPE TED DOC. PART 001 REV. 06 LANG. EN PAGE 1 OF 6
TAG NO.
NORMAL MIN MAX
SYSTEM EQUIPMENT MAN VOLTAGE REMARK REV.

CUSTOMER RATING SPEED POWER CONSUMPT.

CONN. NO.
1. ELECTRICAL POWER / 02
110 VDC
GENERATOR UPS -CONTROL INSIDE MVS BATTERY BASED X800024Z02_7
--- 110 VDC 0.1 kW N/A - kW 03

0.1 kW 0 kW

2. ELECTRICAL POWER / MOTOR RATING POWER CONSUMPTION AS RATED COND. 06


230 V ; 50 HZ
EXPANDER PT ELEC. HEAT TRACING
--- 230 V 0.5 kW N/A - 0.5 kW COMMON FEEDER 12-PT-513 / 514 06
513
EXPANDER PT ELEC. HEAT TRACING
--- 230 V 0.5 kW N/A - 0.5 kW COMMON FEEDER 12-PT-513 / 514 06
514
GENERAL LOCAL CONTROL PANEL AIR FILTER X190953Z02_4
--- 230 V 0.3 kW N/A - 0.3 kW 04

GENERAL UPS - LOCAL CONTROL PANEL X190953Z02_5


--- 230 V 0.5 kW N/A - 0.5 kW 02

GENERAL ENGINEERING STATION X190953Z02_6


--- 230 V 0.5 kW N/A - 0.5 kW 02

GENERATOR GENERATOR STILLSTAND HEATER X800024Z02_10


--- 230 V 3 kW N/A - 3 kW 02

GENERATOR UPS - CONTROL INSIDE MVS X800024Z02_8


--- 230 V 0.25 kW N/A - 0.25 kW 04

GENERATOR ELECTRICAL SPACE HEATER HEA X8002500


--- 230 V 1.5 kW N/A - 1.5 kW 03
12-BJ-002 A
GENERATOR ELECTRICAL SPACE HEATER HEA X8002501
--- 230 V 1.5 kW N/A - 1.5 kW 03
12-BJ-002 B

8.55 kW 8.55 kW

3. ELECTRICAL POWER / POWER CONSUMPTION AS RATED COND. 02


230 V ; 50 Hz (UCP)
GENERAL UPS - POWER 1 (UCP) X190953Z01
--- 230 V 3.75 kW N/A - 3.75 kW INCL. SYSTEM 1 CABINET 02

GENERAL UPS - POWER 2 (UCP) X190953Z02_0


--- 230 V 3.75 kW N/A - 3.75 kW INCL. SYSTEM 1 CABINET 02

GENERAL NORMAL POWER (UCP) X190953Z02_1


--- 230 V 2.5 kW N/A - 2.5 kW 02

10 kW 10 kW

4. ELECTRICAL POWER / MOTOR RATING POWER CONSUMPTION AS RATED COND. 01


400 V ; 50 HZ

10001381241 TED 001 06 EN UTILITY CONSUMPTION BURAXNO HNO3 PAGE 2


DOCUMENT NO. TYPE PART REV. LANG. DOCUMENT H.0100041.01 TRAIN OF 6
TAG NO.
NORMAL MIN MAX
SYSTEM EQUIPMENT MAN VOLTAGE REMARK REV.

CUSTOMER RATING SPEED POWER CONSUMPT.

CONN. NO.
OIL UNIT ELECTRICAL HEATER HEA X1003011
--- 400 V 12 kW N/A - 12 kW 02
12-BJ-001 A
OIL UNIT ELECTRICAL HEATER HEA X1003012
--- 400 V 12 kW N/A - 12 kW 02
12-BJ-001 B
OIL UNIT MOTOR OIL MIST SEPARATOR MOT X1003020
--- 400 V 2.2 kW 2900 1/min 1.8 kW DIESEL GENERATOR 06
12-GB-003-M
OIL UNIT MOTOR MAIN OIL PUMP MOT X1003051
--- 400 V 90 kW 1450 1/min 80.8 kW 06
12-GA-001AM
OIL UNIT MOTOR AUX OIL PUMP MOT X1003052
--- 400 V 90 kW 1450 1/min 80.8 kW 03
12-GA-001BM
OIL UNIT MOTOR EMERGENCY OIL PUMP MOT X1003100
--- 400 V 18.5 kW 1450 1/min 17.1 kW DIESEL GENERATOR 03
12-GA-003M
JACKING OIL UNIT MOTOR JACKING OIL UNIT MOT X1004450
400 V 4 kW 1450 1/min kW DIESEL GENERATOR 06
12-GA-021M
OIL UNIT MOTOR PURIFIER MOT X1004950
--- 400 V 1.5 kW 1423 1/min 1.5 kW 05
12-GB-003M
HYDRAULIC SYSTEM MOTOR HYDRAULIC OIL PUMP 1 MOT X1014451
--- 400 V 11 kW 1450 1/min kW 02
12-GA-15AM
HYDRAULIC SYSTEM MOTOR HYDRAULIC OIL PUMP 2 MOT X1014452
--- 400 V 11 kW 1450 1/min kW 02
12-GA-15BM
STEAM TURBINE MOTOR CONDENSATE PUMP A MOT X2005711
--- 400 V 15 kW 2935 1/min 13.48 kW 04
12-GA-14AM
STEAM TURBINE MOTOR CONDENSATE PUMP B MOT X2005712
--- 400 V 15 kW 2935 1/min 13.48 kW 04
12-GA-14BM
1ST GEAR MOTOR ROTOR TURNING DEVICE MOT X9101801
--- 400 V 22 kW 1480 1/min kW DIESEL GENERATOR 06
12-GG-001M
EXPANDER EXPANDER IGV AUMA-ACTUATOR Z300285
--- 400 V 0.25 kW 2800 1/min kW AUMA SPEED: 16 RPM 02
12-ZZ-595
AIR COMPRESSOR AIR COMPRESSOR IGV AUMA-ACTUATOR Z500285
--- 400 V 0.8 kW 1400 1/min kW AUMA SPEED: 8 RPM 02
12-ZZ-596

305.25 kW 232.96 kW

5. CW COOLER OUTLET OILCOOLER / 01


300 kPa(g); MIN 43 °C ; MAX 48°C
GENERATOR POWER GENERATOR GEN X8001310 BOTH COOLING HEADS IN OPERATION
2.05a 22.5 m³/h - m³/h - m³/h ==> 45 m³/h IN TOTAL DURING OPERATION
02
12-GE-001
GENERATOR POWER GENERATOR GEN X8001310 BOTH COOLING HEADS IN OPERATION
2.06a 22.5 m³/h - m³/h - m³/h ==> 45 m³/h IN TOTAL DURING OPERATION
02
12-GE-001
SEALING SYSTEM SINGLE COOLER HEX X01134442
2.07 0 m³/h - m³/h 14.38 m³/h 06
12-EA-019

10001381241 TED 001 06 EN UTILITY CONSUMPTION BURAXNO HNO3 PAGE 3


DOCUMENT NO. TYPE PART REV. LANG. DOCUMENT H.0100041.01 TRAIN OF 6
TAG NO.
NORMAL MIN MAX
SYSTEM EQUIPMENT MAN VOLTAGE REMARK REV.

CUSTOMER RATING SPEED POWER CONSUMPT.

CONN. NO.
OIL UNIT DOUBLE OIL COOLER HEX X1003200
2.01 78 m³/h 105 m³/h 120 m³/h 03
12-EA-017A/B
HYDRAULIC SYSTEM SINGLE COOLER JO HEX X1014500
2.03 3.6 m³/h 3.0 m³/h 6.0 m³/h 02
12-EC-001
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW
126.6 m³/h 108 m³/h 140.38 m³/h

6. LP STEAM / 01
800 kPa(g);275 °C
STEAM TURBINE EJECTOR STEAM CONDENSER HEX X2005950
5.07 179 kg/h 68 kg/h 247 kg/h 02
12-EA-018
STEAM TURBINE TURBINE SEALING TUR X2002240
5.02 164.7 kg/h 27.3 kg/h 329.4 kg/h 02
12-GF-001
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW
343.7 kg/h 95.3 kg/h 576.4 kg/h

7. INSTRUMENT AIR / 01
650 kPa(g);40 °C
GENERAL VALVES
AS 5 Nm³/h 3 Nm³/h 10 Nm³/h 02

SEALING SYSTEM INSTRUMENT AIR START UP / SHUT DOWN Purging fom min. 30 min
7.01 1500 kg/h - kg/h 1900 kg/h 400 kg/h for expander purging included in MAX consumption 04

AIR PULS FILTER FILTERHOUSE SHUTOFF LOUVRES FLT X5002200


7.04 32 kg/h - kg/h - kg/h 04
12-FD-006
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW 1532 kg/h 0 kg/h 1900 kg/h
5 m³/h 3 m³/h 10 m³/h

8. SEA WATER COOLER OUTLET CONDENSER / 01


250 kPa(g);38.7 °C
STEAM TURBINE STEAM CONDENSER CDN X2005002
2.11 2810 m³/h 2810 m³/h 2810 m³/h 02
12-EA-015
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW
2810 m³/h 2810 m³/h 2810 m³/h

9. HP DEMI WATER / 02
1700 kPa(g);25 °C
WASH WATER SYSTEM WASH WATER NO INLET 1500 l/min @ 100%
2.10 1500 kg/h 1500 kg/h 1700 kg/h 04
1700 l/min @ 70%
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW
1500 kg/h 1500 kg/h 1700 kg/h

10. SEAL AIR COLD / 04


360.68 kPa(g);80 °C
SEALING SYSTEM SEAL AIR COLD
7.01 800 kg/h - kg/h - kg/h NORMAL OPERATION 05

10001381241 TED 001 06 EN UTILITY CONSUMPTION BURAXNO HNO3 PAGE 4


DOCUMENT NO. TYPE PART REV. LANG. DOCUMENT H.0100041.01 TRAIN OF 6
TAG NO.
NORMAL MIN MAX
SYSTEM EQUIPMENT MAN VOLTAGE REMARK REV.

CUSTOMER RATING SPEED POWER CONSUMPT.

CONN. NO.
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW
800 kg/h 0 kg/h 0 kg/h

11. SEAL AIR HOT / 04


364.48 kPa(g);239 °C
SEALING SYSTEM SEAL AIR HOT NORMAL OPERATION FOR
7.01 555 kg/h kg/h 600 kg/h 04
EXPANDER BEARINGS
SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW
555 kg/h 0 kg/h 600 kg/h

12. BOILER FEED WATER / 02


6300 kPa(g);110 °C
INCECTION WATER BYPASS STATION INJECTION WATER INLET BYPASS STATION
2.09 kg/h kg/h 5178 kg/h 02

SEPARATE SUMMATION OF VOLUME FLOW AND MASS FLOW


0 kg/h 0 kg/h 5178 kg/h

- Voltage variation +/-10%; Frequency variation +/- 5%

- Auxiliary oil pump may also run when main oil pump is in operation. (only 1 LO pump is normally operating)

- Emergency oil pump motor, jacking oil pump motor and oil mist fan motor of oil unit and turning gear motor
shall be connected to emergency power supply in case of main power failure.

- Rotor turning device with soft starter in MCC

10001381241 TED 001 06 EN UTILITY CONSUMPTION BURAXNO HNO3 PAGE 5


DOCUMENT NO. TYPE PART REV. LANG. DOCUMENT H.0100041.01 TRAIN OF 6
- Auxiliary jacking oil pump may also run when main jacking oil pump is in operation.
(only 1 JO pump is normally operating)

10001381241 TED 001 06 EN UTILITY CONSUMPTION BURAXNO HNO3 PAGE


DOCUMENT NO. TYPE PART REV. LANG. DOCUMENT H.0100041.01 TRAIN OF 6