Sei sulla pagina 1di 4

ALLIED DEANS BUILDING

Concept Design
CALCULATION OF WATER SUPPLYMAIN PIPE
BY FIXTURE UNITE METHOD ACCORDING TO UNIFORM PLUMING CODE TABLE (A-2)
RISER NO.10
EWC LAV SK TOTAL
Floor F.U
2.5 1 1.5

RISER 10
2nd.F 1 1 1

No. of equip.. 1 1 1 3
Fixture unite 2.5 1 1.5 5

SIZE OF RISER-10
fixture unite = 5 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 5.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s
PIPE SIZE = 3/4 " ASSUME =1" FOR ELECTRIC WATER HEATER AND PLUMBING FIXTURE UNITS
NOTE THAT:- RISER NO.20 ,NO40 ,NO 90 ,,AND NO 70 HAVE THE SAME TYPE OF FIXTURE UNITS

RISER NO.20
EWC LAV SK TOTAL
Floor F.U
2.5 1 1.5
RISER 20

2nd.F 1 1 0

No. of equip.. 1 1 0 2
Fixture unite 2.5 1 0 3.5

SIZE OF RISER-20
fixture unite = 3.5 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 3.50 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s
PIPE SIZE = 3/4 "

RISER NO.30
EQUAL RISER NO.10 +RISER NO.20 = 8.5 = 8.5 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 8.50 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 1 "

RISER NO.40
RISER NO.40 HAS THE SAME EQUIPMENT AS RISER NO.20
RISER NO.40 = 3.5 F.U
PIPE SIZE = 3/4 "

RISER NO.50
RISER NO.50 = RISER NO.40 + RISER NO.30
RISER NO.50 = 12 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 10.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 1 "

RISER NO.60
RISER NO.60 EQUAL(1.5 F.U) 3/4" BECAUSE ITS FEED ONLY ONE KITCHEN SINK 1.5 F.U
ASUME THIS SECTION OF PIPE 1" BECAUSE ITS FEED ELECTRIC WATER HEATER AND KITCHEN SINK

RISER NO.70
RISER NO.70 HAS THE SAME EQUIPMENT AS RISER NO.20
RISER NO.70 = 3.5 F.U
PIPE SIZE = 3/4 "

RISER NO.80
EQUAL RISER NO.70 +RISER NO.60 = 5 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 5.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 3/4 " ASSUME =1" FOR ELECTRIC WATER HEATER AND PLUMBING FIXTURE UNITS

RISER NO.90
RISER NO.90 HAS THE SAME EQUIPMENT AS RISER NO.20
RISER NO.90 = 3.5 F.U
PIPE SIZE = 3/4 "

RISER NO.100
EQUAL RISER NO.90 +RISER NO.80 = 8.5 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 8.50 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 1 "

RISER NO.110
EQUAL RISER NO.100 +RISER NO.50 = 20.5 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 15.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s
PIPE SIZE = 1.25 "

RISER NO.115
RISER NO.115 EQUAL(1.5 F.U) 3/4" BECAUSE ITS FEED ONLY ONE KITCHEN SINK 1.50 F.U
ASUME THIS SECTION OF PIPE 1" BECAUSE ITS FEED ELECTRIC WATER HEATER AND KITCHEN SINK
RISER NO.120
EQUAL RISER NO.110 +RISER NO.115 = 22.00 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 17.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s
PIPE SIZE = 1.25 "

RISER NO.130
EWC LAV SK TOTAL
Floor F.U
2.5 1 1.5

RISER 130
2nd.F 6 0 0

1ST.F 6 0 0

G.F 6 0 0

No. of equip.. 18 0 0 18
Fixture unite 45 0 0 45

SIZE OF RISER-130
fixture unite = 45
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 25.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s
PIPE SIZE = 1.25 "

RISER NO.140
EWC LAV SK TOTAL
Floor F.U
2.5 1 1.5
RISER 140

2nd.F 1 6 1

1ST.F 1 6 1

G.F 1 6 1
No. of equip.. 3 18 3 24
Fixture unite 7.5 18 4.5 30

SIZE OF RISER-140
fixture unite = 30 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 20.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 1.25 "

RISER NO.125
RISER NO.115 EQUAL(1.5 F.U) 3/4" BECAUSE ITS FEED ONLY ONE KITCHEN SINK 1.5 F.U
RISER NO.126
EQUAL RISER NO.120 +RISER NO.125 = 23.50 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 18.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s
PIPE SIZE = 1.25 "

RISER NO.135
EQUAL RISER NO.126 +RISER NO.130 = 68.50 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 35.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 2 "

RISER NO.150
EQUAL RISER NO.135 +RISER NO.140 = 98.50 F.U
ACCORDING TO UNIFORM PLUMING CODE CHART (A-3)
Total Consumption 45.00 GPM
ACCORDING TO UNIFORM PLUMING CODE CHART (A-5)
If velocity = 1.5 m/s ,velocity =5 ft/s

PIPE SIZE = 2 "

CONCLUSION
- WE MAKE OUR CALCULATION ACCORDING TO THE AMXIMUM LOAD
- ACTUAL WE CAN REDUCE OUR SIZING PIPE WATER SUPPLY BECAUSE NOT ALL THE PLUMBING
EQUIPMENTS WILL WORK TOGETHER.

Potrebbero piacerti anche