Sei sulla pagina 1di 6

More reason to love sun

E NE RGY B OOST E R
R ED U C IN G E NE RGY, SAVI NG MO NE Y
Manage your energy in more efficient ways

Our Manufacturer:
EN ER GY B O O S T E R - OPTIV PLUS
Custom Design Available

5 5
RS

RS
UP

UP

TO TO
5 YE 5 YE
A

MAINTENANCE

P R O D U C T F E AT URE S
Variable transformer with columnar design
Digital control system. Intelligent sensing and protection
Efficiency up to 99%
Independent or Dependent Three Phase Regulation
subject to the order
Rich protection functions
Manual bypass
EMI/RFI filter ( Optional )
Surge protection ( Optional )
Remote control with 485 ( Optional )
T E C H N I C A L S PE CIFICATIONS
Input Voltage OVP1 Single phase: 220V or 230V or 240V
OVP3 Three phase: 380V or 400V or 415V
Input Voltage Range -20% to +20% ( Regular. Can be made to -45%, +45% )
Frequency 50Hz or 60Hz
Output Voltage OVP1 Single phase: 220V or 230V or 240V
OVP3 Three phase: 380V or 400V or 415V
Output tolerance +/- 1% typical
Frequency 50Hz or 60Hz
Over load capability 300% 1 sec ; 120% to 200% 20 sec ; 100% to 120% 15 min
Response time < 10ms
Correction time < 1s
Efficiency > 97% typical ( Below 250kVA )
> 98% typical ( Above 250kVA )
Cooling Nature air convection for models below 150kVA
Air forces fan for 150kVA and above
Protection Under/Over voltage, over load, over current, short circuit, manual bypass,
surge arrester ( Optional )
Display Input voltage each phase, Output voltage each phase, Current each phase,
Alarm of protection
Working temperature -15 C to +40 C
Humidity 90%

Dimensions ( cm ) Weight Dimensions ( cm ) Weight


Model Model
WxDxH ( kg ) W x D x H x Unit ( kg )

OVP3 - 20kVA 600 x 600 x 1200 165 OVP3 - 600kVA 120 x 85 x 215 x 2 1760
OVP3 - 30kVA 600 x 600 x 1200 175 OVP3 - 800kVA 120 x 85 x 215 x 2 2200
OVP3 - 50kVA 600 x 600 x 1200 200 OVP3 - 1000kVA 120 x 85 x 215 x 2 2700
OVP3 - 60kVA 600 x 600 x 1200 210 OVP3 - 1200kVA 120 x 85 x 215 x 3 3000
OVP3 - 80kVA 650 x 680 x 1280 230 OVP3 - 1400kVA 120 x 85 x 215 x 3 3400
OVP3 - 100kVA 650 x 680 x 1280 250 OVP3 - 1600kVA 120 x 85 x 215 x 4 4000
OVP3 - 120kVA 650 x 680 x 1280 280 OVP3 - 2000kVA 120 x 85 x 215 x 4 5200
OVP3 - 150kVA 700 x 850 x 1500 350 OVP3 - 2500kVA 120 x 90 x 220 x 4 6280
OVP3 - 180kVA 700 x 850 x 1500 400 OVP3 - 3000kVA 120 x 90 x 220 x 6 7500
OVP3 - 200kVA 700 x 850 x 1500 430 OVP1 - 10kVA 55 x 60 x 115 150
OVP3 - 225kVA 700 x 850 x 1500 465 OVP1 - 20kVA 55 x 60 x 115 175
OVP3 - 250kVA 700 x 850 x 1500 485 OVP1 - 30kVA 55 x 65 x 138 220
OVP3 - 320kVA 750 x 900 x 1600 570 OVP1 - 50kVA 65 x 90 x 150 290
OVP3 - 400kVA 750 x 900 x 1600 650 OVP1 - 80kVA 71 x 92 x 162 370
OVP3 - 500kVA 750 x 900 x 1600 750 OVP1 - 100kVA 71 x 92 x 162 430

Note: The weights and dimensions may be changed without prior notice. Please contact us for confirmation.
I NCO MI N G S U P P LY : WHAT’ S THE PROB L E M ?
Based on Malaysian Standard MS1979 with effect from 1st January 2008, the nominal voltage supply has been reduced from
240Vac to 230Vac, +10% and -6%, a range of between 253V and 216V. However, to allow end electricity to travel long distances
across the grid to reach end users, it is typically supplied at a higher voltage than required.

Most electrical equipment and machinery on a site, are designed to operate efficiently at 220V to 230V. When supplied with a
higher voltage (overvoltage), there’s no enhancement to their performances, rather the excess energy is lost through heat or
vibration.

Users had to pay for this wasted energy without gaining any increase in output. Overvoltage can also damage connected
equipment, negatively affecting performance, significantly reducing expected rated life and increasing the possibility of break
downs.

Lastly, the quality and level of the supplied voltage can vary throughout the day depending on fluctuations in demand and supply.
Sags, spikes and transients in the supply can result operational problems and deterioration to connected appliances.

WH AT I S E N E RGY B O O S TE R?
Energy Booster aims to reduce Upper limit voltage
253V
electricity usage, power demand and in Malaysia
High voltage
You could be
cost, improve the performance and
paying for this
working efficiency of the loads by level of voltage 247V Average voltage supplied
reducing supply voltage received. It can
Energy Booster
improve power quality by reducing
240V Historic AUS voltage
harmonic and transient voltages as
well as balancing phase voltages. A Power supplied
at steady rate
reduction and balancing in electricity Energy Booster
( 220V or 240V )
can reduce your 230V Standard Voltage
supply voltage achieves a saving in
incoming voltage
energy consumption (kWh) and a leading to lower
Equipment
electricity consumption Most equipment is
reduction in maximum demand (KW & lasts longer
and reduced bills 220V designed to operate
KVA). Energy Booster is not the same most efficiently at
as Power Factor Correction. this level of voltage
Electricity
216V Low voltage limit bill lowered

SAVI N G C A L C U L AT O R - OHM ’ S L AW
Energy Booster can be explained using Non-optimised supply Optimised supply
Ohm’s law:
Power = Voltage2 ÷ Resistance 242V x 242V ( V2 ) 220V x 220V ( V2 )
Power ( P ) = Power ( P ) =
20 Ω ( R ) 20 Ω ( R )
These calculation are based on a constant
58 564V 48 400V
resistance (R) of 20 Ohms ( Ω ), a 2928W ( P ) = 2420W ( P ) =
20 Ω ( R ) 20 Ω ( R )
non-optimised voltage (V) of 242V and an
2928W 2420W
optimised voltage of 220V, with a cost of 2.928kW = 2.42kW =
1000 1000
RM0.37/kWh.

The given calculation and percentage savings RM0.37/kWh x 2.928kW = RM1.08336/h RM0.37/kWh x 2.42kW = RM0.8954/h
are for example purposes only. Please note,
savings will vary depending on power supply RM1.08336 x 24hrs = RM26.00/day RM0.8954 x 24hrs = RM21.49/day
and electrical appliances used.
Save RM4.51 / day ( 17.3% )
FABULO U S S U N V I E W S DN B HD is currently one of the leading system and
service providers for a wide range of solar PV systems and Energy Booster. As part of global development of being
environmentally responsible, our company strive to achieve our goals of co-existing between business and the green
environment by providing excellent quality solar PV system, Energy Booster and exceptional services to our
customers. Sunview Power Sdn Bhd is our subsidiary company, with Energy Booster and other energy saving
products. We are ISO9001:2015 certified.

GRIDST O NE E L E C T RI C , founded in 1983, is a leading manufacturer of automatic voltage


stabilizer and transformer. The products currently include digital static voltage stabilizer, digital servo Energy Booster,
power factor correction units, oil immersed voltage regulator, UPS. LV and MV transformers and reactors. Thanks to
over 30 years in the business and on going technical research, GridStone have become a competitive high-tech
company, and meet the requirements of a constantly growing number of customers through design, production and
service.

Besides standard production, GridStone is flexible and strong at custom design and production according to the
customer’s specification. Expert training and technical support are available to serve the customers quickly and
professionally. GridStone factories are ISO9001 and ISO14001 certified.

WHY U S?
Help saves money on electricity bills Easy installation by qualified electrician
Reduces energy waste and carbon emissions Suitable to work alongside solar PV installations
Increase the life span of electrical appliances High flexibility

CON TAC T
Headquarter Branch Office
Fabulous Sunview SDN BHD Fabulous Sunview Philippine Inc

Lot 763-2A, Jalan Subang 4, Unit 17-H, 17th Floor, Fort Palm Spring Condominium,
Kawasan Perusahaan Sungai Penaga, 30th Street Corner 1st Avenue, Bonifacio Global City,
47610 Subang Jaya, Selangor Darul Ehsan, Malaysia. Fort Bonifacio, Taguig City, 1634 Metro Manila, Philippines.

Tel: +603 8081 2764 Tel: +63 2503 9640


Fax: +603 8081 2794 H/P: +63 917 884 4884
sales@sunview.com.my nilson@sunview.com.my

www.sunview.com.my
B ENE F IT S
Cut electricity cost Protect against damaging transients (power spikes)
Average savings of 10%-20% on energy consumption Reduce operating temperatures of motors
Reduces carbon emissions Improves life expectancy of equipment
Manages Phase balancing Reduces maintenance costs

HOW MU CH C A N B E SAVE ?
The level of energy saving will be decided by the combination of the incoming supply voltage level and the types of electrical
equipment in use. The higher the supply voltage, the more energy saved. Note that different types of electrical equipment deliver
different levels of energy saving even with the same reduction in voltage.

Energy Booster works best on inductive loads, such as electric motors ( air conditioning, refrigerators, pumps and fans ) and
incandescent and magnetically ballasted lighting. Energy savings that can be achieved where the majority of electrical
consumption is similar, can be as high as 10-20%.

R IGHT F O R YO U ?
Overhea ng of transformers,
Unstable equipment opera on
switchboards and cabling

Nuisance tripping of circuit breakers


High energy costs
or control equipment

WH O C A N SAV E ?
Energy Booster can benefit facili es with induc ve loads
such as three-phase induc on motors, air condi oning and
refrigera on which can be found in:

Commercial, office, retail buildings


and supermarkets

Government and educa onal facili es

Manufacturing, processing
and warehouse opera ons

Since 1993, electrical products must carry a CE mark to show that they have been tested and comply with all the relevant new harmonized standards hence any
electrical equipment carrying the CE mark has to be capable of working between 207V – 253V.

Potrebbero piacerti anche